HomeMy WebLinkAboutLA178307 Truss RepairsAlpine, an ITW Company 2820 N. Great Southwest Parkway Grand Prarie, TX 75050 www.alpineitw.com Site Information:Page 1: Customer: Automated Building Components, Inc.Job Number: T201946-REP Job Description: Dsgnr:Shane Anders Address: Job Engineering Criteria: Design Code: IRC 2018 IntelliVIEW Version: 19.02.02B through 20.01.00 JRef #: 1WVd90730015 Wind Standard: ASCE 7-16 Wind Speed (mph): 115 Roof Load (psf): 35.00-10.00- 0.00-10.00 Building Type: Closed Floor Load (psf): None This package contains general notes pages, 6 truss drawing(s) and 2 detail(s). Item Drawing Number Truss Item Drawing Number Truss 1 140.20.0736.19683 D1 2 140.20.0736.32457 D2 3 140.20.0736.39280 D4 4 139.20.1607.23863 D1REP 5 140.20.0759.45007 D2REP 6 140.20.0916.03350 D4REP 7 BRCLBSUB0119 8 160TL Printed 5/19/2020 9:26:03 AM 05/19/2020 General Notes Truss Design Engineer Scope of Work, Design Assumptions and Design Responsibilities: The design responsibilities assumed in the preparation of these design drawings are those specified in ANSI/TPI 1, Chapter 2; and the National Design Standard for Metal Plate Connected Wood Truss Construction, by the Truss Plate Institute. The truss component designs conform to the applicable provisions of ANSI/TPI 1 and NDS, the National Design Specification for Wood Construction by AWC. The truss component designs are based on the specified loading and dimension information furnished by others to the Truss Design Engineer. The Truss Design Engineer has no duty to independently verify the accuracy or completeness of the information provided by others and may rely on that information without liability. The responsibility for verification of that information remains with others neither employed nor controlled by the Truss Design Engineer. The Truss Design Engineer’s seal and signature on the attached drawings, or cover page listing these drawings, indicates acceptance of professional engineering responsibility solely for the truss component designs and not for the technical information furnished by others which technical information and consequences thereof remain their sole responsibility. The suitability and use of these drawings for any particular structure is the responsibility of the Building Designer in accordance with ANSI/TPI 1 Chapter 2. The Building Designer is responsible for determining that the dimensions and loads for each truss component match those required by the plans and by the actual use of the individual component, and for ascertaining that the loads shown on the drawings meet or exceed applicable building code requirements and any additional factors required in the particular application. Truss components using metal connector plates with integral teeth shall not be placed in environments that will cause the moisture content of the wood in which plates are embedded to exceed 19% and/or cause corrosion of connector plates and other metal fasteners. The Truss Design Engineer shall not be responsible for items beyond the specific scope of the agreed contracted work set forth herein, including but not limited to: verifying the dimensions of the truss component, calculation of any of the truss component design loads, inspection of the truss components before or after installation, the design of temporary or permanent bracing and their attachment required in the roof and/or floor systems, the design of diaphragms or shear walls, the design of load transfer connections to and from diaphragms and shear walls, the design of load transfer to the foundation, the design of connections for truss components to their bearing supports, the design of the bearing supports, installation of the truss components, observation of the truss component installation process, review of truss assembly procedures, sequencing of the truss component installation, construction means and methods, site and/or worker safety in the installation of the truss components and/or its connections. This document may be a high quality facsimile of the original engineering document which is a digitally signed electronic file with third party authentication. A wet or embossed seal copy of this engineering document is available upon request. Temporary Lateral Restraint and Bracing: Temporary lateral restraint and diagonal bracing shall be installed according to the provisions of BCSI chapters B1, B2, B7 and/or B10 (Building Component Safety Information, by TPI and SBCA), or as specified by the Building Designer or other Registered Design Professional. The required locations for lateral restraint and/or bracing depicted on these drawings are only for the permanent lateral support of the truss members to reduce buckling lengths, and do not apply to and may not be relied upon for the temporary stability of the truss components during their installation. Permanent Lateral Restraint and Bracing: The required locations for lateral restraint or bracing depicted on these drawings are for the permanent lateral support of the truss members to reduce buckling lengths. Permanent lateral support shall be installed according to the provisions of BCSI chapters B3, B7 and/or B10, or as specified by the Building Designer or other Registered Design Professional. These drawings do not depict or specify installation/erection bracing, wind bracing, portal bracing or similar building stability bracing which are parts of the overall building design to be specified, designed and detailed by the Building Designer. Connector Plate Information: Alpine connector plates are made of ASTM A653 or ASTM A1063 galvanized steel with the following designations, gauges and grades: W=Wave, 20ga, grade 40; H=High Strength, 20ga, grade 60; S=Super Strength, 18ga, grade 60. Information on model code compliance is contained in the ICC Evaluation Service report ESR-1118, available on-line at www.icc-es.org. Fire Retardant Treated Lumber: Fire retardant treated lumber must be properly re-dried and maintained below 19% or less moisture level through all stages of construction and usage. Fire retardant treated lumber may be more brittle than untreated lumber. Special handling care must be taken to prevent breakage during all handling activities. Page 1 of 3 General Notes (continued) Key to Terms: Information provided on drawings reflects a summary of the pertinent information required for the truss design. Detailed information on load cases, reactions, member lengths, forces and members requiring permanent lateral support may be found in calculation sheets available upon written request. BCDL = Bottom Chord standard design Dead Load in pounds per square foot. BCLL = Bottom Chord standard design Live Load in pounds per square foot. CL = Certified lumber. Des Ld = total of TCLL, TCDL, BCLL and BCDL Design Load in pounds per square foot. FRT = Fire Retardant Treated lumber. FRT-DB = D-Blaze Fire Retardant Treated lumber. FRT-DC = Dricon Fire Retardant Treated lumber. FRT-FP = FirePRO Fire Retardant Treated lumber. FRT-FL = FlamePRO Fire Retardant Treated lumber. FRT-FT = FlameTech Fire Retardant Treated lumber. FRT-PG = PYRO-GUARD Fire Retardant Treated lumber. g = green lumber. HORZ(LL) = maximum Horizontal panel point deflection due to Live Load, in inches. HORZ(TL) = maximum Horizontal panel point long term deflection in inches, due to Total Load, including creep adjustment. HPL = additional Horizontal Load added to a truss Piece in pounds per linear foot or pounds. Ic = Incised lumber. FJ = Finger Jointed lumber. L/# = user specified divisor for limiting span/deflection ratio for evaluation of actual L/defl value. L/defl = ratio of Length between bearings, in inches, divided by the vertical Deflection due to creep, in inches, at the referenced panel point. Reported as 999 if greater than or equal to 999. Loc = Location, starting location of left end of bearing or panel point (joint) location of deflection. Max BC CSI = Maximum bending and axial Combined Stress Index for Bottom Chords for of all load cases. Max TC CSI = Maximum bending and axial Combined Stress Index for Top Chords for of all load cases. Max Web CSI= Maximum bending and axial Combined Stress Index for Webs for of all load cases. NCBCLL = Non-Concurrent Bottom Chord design Live Load in pounds per square foot. PL = additional Load applied at a user specified angle on a truss Piece in pounds per linear foot or pounds. PLB = additional vertical load added to a Bottom chord Piece of a truss in pounds per linear foot or pounds PLT = additional vertical load added to a Top chord Piece of a truss in pounds per linear foot or pounds. PP = Panel Point. R = maximum downward design Reaction, in pounds, from all specified gravity load cases, at the indicated location (Loc). -R = maximum upward design Reaction, in pounds, from all specified gravity load cases, at the identified location (Loc). Rh = maximum horizontal design Reaction in either direction, in pounds, from all specified gravity load cases, at the indicated location (Loc). RL = maximum horizontal design Reaction in either direction, in pounds, from all specified non-gravity (wind or seismic) load cases, at the indicated location (Loc). Rw = maximum downward design Reaction, in pounds, from all specified non-gravity (wind or seismic) load cases, at the identified location (Loc). TCDL = Top Chord standard design Dead Load in pounds per square foot. TCLL = Top Chord standard design Live Load in pounds per square foot. U = maximum Upward design reaction, in pounds, from all specified non-gravity (wind or seismic) load cases, at the indicated location (Loc). VERT(CL) = maximum Vertical panel point deflection in inches due to Live Load and Creep Component of Dead Load in inches. VERT(CTL) = maximum Vertical panel point deflection ratios due to Live Load and Creep Component of Dead Load, and maximum long term Vertical panel point deflection in inches due to Total load, including creep adjustment. VERT(LL) = maximum Vertical panel point deflection in inches due to Live Load. VERT(TL) = maximum Vertical panel point long term deflection in inches due to Total load, including creep adjustment. W = Width of non-hanger bearing, in inches. Refer to ASCE-7 for Wind and Seismic abbreviations. Uppercase Acronyms not explained above are as defined in TPI 1. Page 2 of 3 References: 1. AWC: American Wood Council; 222 Catoctin Circle SE, Suite 201; Leesburg, VA 20175; www.awc.org. 2. ICC: International Code Council; www.iccsafe.org. 3. Alpine, a division of ITW Building Components Group Inc.: 13723 Riverport Drive, Suite 200, Maryland Heights, MO 63043; www.alpineitw.com. 4. TPI: Truss Plate Institute, 2670 Crain Highway, Suite 203, Waldorf, MD 20601; www.tpinst.org. 5. SBCA: Wood Truss Council of America, 6300 Enterprise Lane, Madison, WI 53719; www.sbcindustry.com. Page 3 of 3 **WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAWING!**IMPORTANT**FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERSTrusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise,top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions. Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing,any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses.A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitabilityand use of this drawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2. For more information see this job's general notes page and these web sites: ALPINE: www.alpineitw.com; TPI: www.tpinst.org; SBCA: www.sbcindustry.com; ICC: www.iccsafe.org 2820 N. Great Southwest ParkwayGrand Prairie, TX 75050 Lumber Top chord: 2x4 SPF 1650f-1.5E;Bot chord: 2x4 SPF 1650f-1.5E; Webs: 2x4 SPF #1/#2; w2,w3,w10 2x3 SPF #3; w4,w5,w9 2x3 SPF #1/#2; Bracing (a) Continuous lateral restraint equally spaced on member. Loading Bottom chord checked for 10.00 psf non-concurrentlive load. Purlins In lieu of structural panels use purlins to brace all flat TC @ 24" oc. Wind Wind loads based on MWFRS with additional C&Cmember design. Wind loading based on both gable and hip roof types. Maximum Reactions (lbs) Gravity Non-Gravity Loc R+/ R-/ Rh / Rw / U / RL P 1123 /-/-/499 /-/301 L 2775 /-/-/1103 /-/- J 1004 /-/-/485 /-/- Wind reactions based on MWFRS P Brg Width = 5.5 Min Req =1.8 L Brg Width = 5.5 Min Req =4.0 J Brg Width = 5.5 Min Req =1.6 Bearings P, L, & J Fcperp = 425psi. Members not listed have forces less than 375# Maximum Top Chord Forces Per Ply (lbs) Chords Tens.Comp. B - C 89 -1123 C - D 184 -579 D - E 407 0 Chords Tens.Comp. E - F 406 0 F - G 189 -722 Maximum Bot Chord Forces Per Ply(lbs) Chords Tens.Comp. O - N 747 -154 Chords Tens.Comp. K - J 638 0 Maximum Web Forces Per Ply(lbs) Webs Tens.Comp. B - P 95 -1065 B - O 660 0 C - N 137 -668 D - N 583 -16 D - L 59 -1122 E - L 265 -724 Webs Tens.Comp. L - F 54 -1014 F - K 742 -59 K - G 207 -569 G - J 0 -759 H - J 131 -408 Loading Criteria (psf) TCLL:35.00 TCDL:10.00 BCLL:0.00 BCDL:10.00 Des Ld:55.00 NCBCLL:10.00 Soffit:0.00 Load Duration: 1.15 Spacing: 24.0 " Wind Criteria Wind Std:ASCE 7-16 Speed:115 mph Enclosure: Closed Risk Category: II EXP: C Kzt: NA Mean Height: 16.78 ft TCDL: 6.0 psf BCDL: 6.0 psf MWFRS Parallel Dist: h to 2h C&C Dist a: 3.89 ft Loc. from endwall: not in 9.00 ft GCpi: 0.18 Wind Duration: 1.60 Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Code / Misc Criteria Bldg Code:IRC 2018 TPI Std:2014 Rep Fac: Yes FT/RT:16(0)/10(0) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL):0.032 O 999 240 VERT(CL):0.055 O 999 180 HORZ(LL):0.014 C - - HORZ(TL):0.023 C - - Creep Factor: 2.0 Max TC CSI:0.902 Max BC CSI:0.592 Max Web CSI:0.907 VIEW Ver: 19.02.02B.0122.16 Job Number:T201946-REP Dsgnr:Shane Anders Truss Label:D1 Ply: 1 Qty:7 SEQN:165524 COMN FROM: Cust: R9073 JRef:1WVd90730015 T10 DrwNo:140.20.0736.19683 DW /BM 05/18/2020 w2 w3 w4 w5 w9 w10 20'6"4 18'4"12 6'10"12 6'10"12 13'5"8 6'6"12 20'5"13 7'0"5 25'5"8 4'11"11 32'8"11 7'3"3 38'11" 6'2"5 6'8"4 6'8"4 13'5"8 6'9"4 19'5"8 6' 20'5"13 1'0"5 29'7"4 9'1"7 38'11" 9'3"121'3"1'3" 1'2"11'9"1412'0"3(a) (a)(a)(a) (a) A B C D E F G H I JKLMNOP 9.5 12 3X6 3X4 3X4 3X4 5X6 3X4 3X8 1.5X4 4X8 5X6 4X4 3X4 1.5X4 3X4 **WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAWING!**IMPORTANT**FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERSTrusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise,top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions. Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing,any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses.A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitabilityand use of this drawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2. For more information see this job's general notes page and these web sites: ALPINE: www.alpineitw.com; TPI: www.tpinst.org; SBCA: www.sbcindustry.com; ICC: www.iccsafe.org 2820 N. Great Southwest ParkwayGrand Prairie, TX 75050 Lumber Top chord: 2x4 SPF 1650f-1.5E;Bot chord: 2x4 SPF 1650f-1.5E; Webs: 2x4 SPF #1/#2; w2,w3,w10 2x3 SPF #3; w4,w5,w9 2x3 SPF #1/#2; Bracing (a) Continuous lateral restraint equally spaced on member. Loading Bottom chord checked for 10.00 psf non-concurrentlive load. Purlins In lieu of structural panels use purlins to brace all flat TC @ 24" oc. Wind Wind loads based on MWFRS with additional C&Cmember design. Wind loading based on both gable and hip roof types. Maximum Reactions (lbs) Gravity Non-Gravity Loc R+/ R-/ Rh / Rw / U / RL P 1123 /-/-/499 /-/301 L 2775 /-/-/1103 /-/- J 1004 /-/-/485 /-/- Wind reactions based on MWFRS P Brg Width = 5.5 Min Req =1.8 L Brg Width = 5.5 Min Req =4.0 J Brg Width = 5.5 Min Req =1.6 Bearings P, L, & J Fcperp = 425psi. Members not listed have forces less than 375# Maximum Top Chord Forces Per Ply (lbs) Chords Tens.Comp. B - C 89 -1123 C - D 184 -579 D - E 407 0 Chords Tens.Comp. E - F 406 0 F - G 189 -722 Maximum Bot Chord Forces Per Ply(lbs) Chords Tens.Comp. O - N 747 -154 Chords Tens.Comp. K - J 638 0 Maximum Web Forces Per Ply(lbs) Webs Tens.Comp. B - P 95 -1065 B - O 660 0 C - N 137 -668 D - N 583 -16 D - L 59 -1122 E - L 265 -724 Webs Tens.Comp. L - F 54 -1014 F - K 742 -59 K - G 207 -569 G - J 0 -759 H - J 131 -408 Loading Criteria (psf) TCLL:35.00 TCDL:10.00 BCLL:0.00 BCDL:10.00 Des Ld:55.00 NCBCLL:10.00 Soffit:0.00 Load Duration: 1.15 Spacing: 24.0 " Wind Criteria Wind Std:ASCE 7-16 Speed:115 mph Enclosure: Closed Risk Category: II EXP: C Kzt: NA Mean Height: 16.78 ft TCDL: 6.0 psf BCDL: 6.0 psf MWFRS Parallel Dist: h to 2h C&C Dist a: 3.89 ft Loc. from endwall: not in 9.00 ft GCpi: 0.18 Wind Duration: 1.60 Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Code / Misc Criteria Bldg Code:IRC 2018 TPI Std:2014 Rep Fac: Yes FT/RT:16(0)/10(0) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL):0.032 O 999 240 VERT(CL):0.055 O 999 180 HORZ(LL):0.014 C - - HORZ(TL):0.023 C - - Creep Factor: 2.0 Max TC CSI:0.902 Max BC CSI:0.592 Max Web CSI:0.907 VIEW Ver: 19.02.02B.0122.16 Job Number:T201946-REP Dsgnr:Shane Anders Truss Label:D1 Ply: 1 Qty:7 SEQN:165524 COMN FROM: Cust: R9073 JRef:1WVd90730015 T10 DrwNo:140.20.0736.19683 DW /BM 05/18/2020 w2 w3 w4 w5 w9 w10 20'6"4 18'4"12 6'10"12 6'10"12 13'5"8 6'6"12 20'5"13 7'0"5 25'5"8 4'11"11 32'8"11 7'3"3 38'11" 6'2"5 6'8"4 6'8"4 13'5"8 6'9"4 19'5"8 6' 20'5"13 1'0"5 29'7"4 9'1"7 38'11" 9'3"121'3"1'3" 1'2"11'9"1412'0"3(a) (a)(a)(a) (a) A B C D E F G H I JKLMNOP 9.5 12 3X6 3X4 3X4 3X4 5X6 3X4 3X8 1.5X4 4X8 5X6 4X4 3X4 1.5X4 3X4 05/19/2020 **WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAWING!**IMPORTANT**FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERSTrusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise,top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions. Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing,any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses.A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitabilityand use of this drawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2. For more information see this job's general notes page and these web sites: ALPINE: www.alpineitw.com; TPI: www.tpinst.org; SBCA: www.sbcindustry.com; ICC: www.iccsafe.org 2820 N. Great Southwest ParkwayGrand Prairie, TX 75050 Lumber Top chord: 2x4 SPF 1650f-1.5E;TC2 2x4 SPF #1/#2; Bot chord: 2x4 SPF 1650f-1.5E;Webs: 2x4 SPF #1/#2; w2,w3,w10 2x3 SPF #3;w5 2x4 SPF 1650f-1.5E; w9 2x3 SPF #1/#2; Bracing (a) Continuous lateral restraint equally spaced onmember. Loading Bottom chord checked for 10.00 psf non-concurrent live load. Purlins In lieu of structural panels use purlins to brace all flatTC @ 24" oc. Wind Wind loads based on MWFRS with additional C&C member design. Wind loading based on both gable and hip roof types. Maximum Reactions (lbs) Gravity Non-Gravity Loc R+/ R-/ Rh / Rw / U / RL O 637 /-/-/256 /-/301 M 2417 /-/-/1056 /-/- J 1720 /-/-/788 /-/- Wind reactions based on MWFRS O Brg Width = 5.5 Min Req =1.5 M Brg Width = 5.5 Min Req =3.4 J Brg Width = 5.5 Min Req =2.7 Bearings O, M, & J Fcperp = 425psi. Members not listed have forces less than 375# Maximum Top Chord Forces Per Ply (lbs) Chords Tens.Comp. B - C 60 -459 C - D 393 -48 D - E 278 -854 Chords Tens.Comp. E - F 278 -854 F - G 304 -1709 Maximum Bot Chord Forces Per Ply(lbs) Chords Tens.Comp. L - K 981 0 Chords Tens.Comp. K - J 1373 -37 Maximum Web Forces Per Ply(lbs) Webs Tens.Comp. B - O 72 -581 C - M 158 -672 M - D 166 -1788 D - L 1252 -150 E - L 242 -659 Webs Tens.Comp. F - K 633 -35 K - G 182 -436 G - J 59 -1670 H - J 155 -507 Loading Criteria (psf) TCLL:35.00 TCDL:10.00 BCLL:0.00 BCDL:10.00 Des Ld:55.00 NCBCLL:10.00 Soffit:0.00 Load Duration: 1.15 Spacing: 24.0 " Wind Criteria Wind Std:ASCE 7-16 Speed:115 mph Enclosure: Closed Risk Category: II EXP: C Kzt: NA Mean Height: 16.78 ft TCDL: 6.0 psf BCDL: 6.0 psf MWFRS Parallel Dist: h to 2h C&C Dist a: 3.89 ft Loc. from endwall: not in 9.00 ft GCpi: 0.18 Wind Duration: 1.60 Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Code / Misc Criteria Bldg Code:IRC 2018 TPI Std:2014 Rep Fac: Yes FT/RT:16(0)/10(0) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL):0.066 K 999 240 VERT(CL):0.108 K 999 180 HORZ(LL):0.035 H - - HORZ(TL):0.057 H - - Creep Factor: 2.0 Max TC CSI:0.789 Max BC CSI:0.708 Max Web CSI:0.775 VIEW Ver: 19.02.02B.0122.16 Job Number:T201946-REP Dsgnr:Shane Anders Truss Label:D2 Ply: 1 Qty:8 SEQN:165527 COMN FROM: Cust: R9073 JRef:1WVd90730015 T2 DrwNo:140.20.0736.32457 DW /BM 05/18/2020 TC2 w2 w3 w5 w9 w10 10'8"12 28'2"4 6'4"15 6'4"15 13'5"8 7'0"9 19'5"8 6' 25'5"8 6' 32'2"10 6'9"2 38'11" 6'8"6 6'2"7 6'2"7 10'8"12 4'6"5 19'5"8 8'8"12 29'2"4 9'8"12 38'11" 9'8"121'3"1'3" 1'2"11'9"1412'0"3(a)(a)(a)(a) (a) A B C D E F G H I JKLMNO 9.5 12 4X4 2X4 3X4 3X4 4X4 5X6 1.5X4 6X8 5X6 4X4 4X6 2X4 4X6 **WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAWING!**IMPORTANT**FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERSTrusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise,top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions. Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing,any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses.A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitabilityand use of this drawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2. For more information see this job's general notes page and these web sites: ALPINE: www.alpineitw.com; TPI: www.tpinst.org; SBCA: www.sbcindustry.com; ICC: www.iccsafe.org 2820 N. Great Southwest ParkwayGrand Prairie, TX 75050 Lumber Top chord: 2x4 SPF 1650f-1.5E;TC2 2x4 SPF #1/#2; Bot chord: 2x4 SPF 1650f-1.5E;Webs: 2x4 SPF #1/#2; w2,w3,w10 2x3 SPF #3;w5 2x4 SPF 1650f-1.5E; w9 2x3 SPF #1/#2; Bracing (a) Continuous lateral restraint equally spaced onmember. Loading Bottom chord checked for 10.00 psf non-concurrent live load. Purlins In lieu of structural panels use purlins to brace all flatTC @ 24" oc. Wind Wind loads based on MWFRS with additional C&C member design. Wind loading based on both gable and hip roof types. Maximum Reactions (lbs) Gravity Non-Gravity Loc R+/ R-/ Rh / Rw / U / RL O 637 /-/-/256 /-/301 M 2417 /-/-/1056 /-/- J 1720 /-/-/788 /-/- Wind reactions based on MWFRS O Brg Width = 5.5 Min Req =1.5 M Brg Width = 5.5 Min Req =3.4 J Brg Width = 5.5 Min Req =2.7 Bearings O, M, & J Fcperp = 425psi. Members not listed have forces less than 375# Maximum Top Chord Forces Per Ply (lbs) Chords Tens.Comp. B - C 60 -459 C - D 393 -48 D - E 278 -854 Chords Tens.Comp. E - F 278 -854 F - G 304 -1709 Maximum Bot Chord Forces Per Ply(lbs) Chords Tens.Comp. L - K 981 0 Chords Tens.Comp. K - J 1373 -37 Maximum Web Forces Per Ply(lbs) Webs Tens.Comp. B - O 72 -581 C - M 158 -672 M - D 166 -1788 D - L 1252 -150 E - L 242 -659 Webs Tens.Comp. F - K 633 -35 K - G 182 -436 G - J 59 -1670 H - J 155 -507 Loading Criteria (psf) TCLL:35.00 TCDL:10.00 BCLL:0.00 BCDL:10.00 Des Ld:55.00 NCBCLL:10.00 Soffit:0.00 Load Duration: 1.15 Spacing: 24.0 " Wind Criteria Wind Std:ASCE 7-16 Speed:115 mph Enclosure: Closed Risk Category: II EXP: C Kzt: NA Mean Height: 16.78 ft TCDL: 6.0 psf BCDL: 6.0 psf MWFRS Parallel Dist: h to 2h C&C Dist a: 3.89 ft Loc. from endwall: not in 9.00 ft GCpi: 0.18 Wind Duration: 1.60 Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Code / Misc Criteria Bldg Code:IRC 2018 TPI Std:2014 Rep Fac: Yes FT/RT:16(0)/10(0) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL):0.066 K 999 240 VERT(CL):0.108 K 999 180 HORZ(LL):0.035 H - - HORZ(TL):0.057 H - - Creep Factor: 2.0 Max TC CSI:0.789 Max BC CSI:0.708 Max Web CSI:0.775 VIEW Ver: 19.02.02B.0122.16 Job Number:T201946-REP Dsgnr:Shane Anders Truss Label:D2 Ply: 1 Qty:8 SEQN:165527 COMN FROM: Cust: R9073 JRef:1WVd90730015 T2 DrwNo:140.20.0736.32457 DW /BM 05/18/2020 TC2 w2 w3 w5 w9 w10 10'8"12 28'2"4 6'4"15 6'4"15 13'5"8 7'0"9 19'5"8 6' 25'5"8 6' 32'2"10 6'9"2 38'11" 6'8"6 6'2"7 6'2"7 10'8"12 4'6"5 19'5"8 8'8"12 29'2"4 9'8"12 38'11" 9'8"121'3"1'3" 1'2"11'9"1412'0"3(a)(a)(a)(a) (a) A B C D E F G H I JKLMNO 9.5 12 4X4 2X4 3X4 3X4 4X4 5X6 1.5X4 6X8 5X6 4X4 4X6 2X4 4X6 05/19/2020 **WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAWING!**IMPORTANT**FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERSTrusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise,top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions. Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing,any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses.A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitabilityand use of this drawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2. For more information see this job's general notes page and these web sites: ALPINE: www.alpineitw.com; TPI: www.tpinst.org; SBCA: www.sbcindustry.com; ICC: www.iccsafe.org 2820 N. Great Southwest ParkwayGrand Prairie, TX 75050 Lumber Top chord: 2x4 SPF 1650f-1.5E;TC2 2x4 SPF #1/#2; Bot chord: 2x4 SPF 1650f-1.5E;Webs: 2x4 SPF #1/#2; w3,w9 2x3 SPF #3;w4 2x3 SPF #1/#2; w8 2x4 SPF 1650f-1.5E; Bracing (a) Continuous lateral restraint equally spaced onmember. Loading Bottom chord checked for 10.00 psf non-concurrent live load. Purlins In lieu of structural panels use purlins to brace all flatTC @ 24" oc. Wind Wind loads based on MWFRS with additional C&C member design. Right cantilever is exposed to wind Wind loading based on both gable and hip roof types. Maximum Reactions (lbs) Gravity Non-Gravity Loc R+/ R-/ Rh / Rw / U / RL N 1772 /-/-/802 /-/301 K 2695 /-/-/1005 /192 /- O 389 /-/-/291 /-/- Wind reactions based on MWFRS N Brg Width = 5.5 Min Req =2.8 K Brg Width = 5.5 Min Req =3.9 O Brg Width = 3.5 Min Req =1.5 Bearings N, K, & O Fcperp = 425psi. Members not listed have forces less than 375# Maximum Top Chord Forces Per Ply (lbs) Chords Tens.Comp. C - D 325 -1784 D - E 258 -942 Chords Tens.Comp. E - F 258 -942 F - G 692 -154 Maximum Bot Chord Forces Per Ply(lbs) Chords Tens.Comp. N - M 1429 -108M - L 1041 -51 Chords Tens.Comp. L - K 394 -106K - J 481 -266 Maximum Web Forces Per Ply(lbs) Webs Tens.Comp. B - N 197 -509 N - C 26 -1744 C - M 243 -441 M - D 637 -91 E - L 238 -660 Webs Tens.Comp. L - F 1298 -218 F - K 356 -2031 K - G 287 -638 H - J 197 -435 Loading Criteria (psf) TCLL:35.00 TCDL:10.00 BCLL:0.00 BCDL:10.00 Des Ld:55.00 NCBCLL:10.00 Soffit:0.00 Load Duration: 1.15 Spacing: 24.0 " Wind Criteria Wind Std:ASCE 7-16 Speed:115 mph Enclosure: Closed Risk Category: II EXP: C Kzt: NA Mean Height: 16.78 ft TCDL: 6.0 psf BCDL: 6.0 psf MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 3.89 ft Loc. from endwall: Any GCpi: 0.18 Wind Duration: 1.60 Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Code / Misc Criteria Bldg Code:IRC 2018 TPI Std:2014 Rep Fac: Yes FT/RT:16(0)/10(0) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL):0.066 M 999 240 VERT(CL):0.111 M 999 180 HORZ(LL):0.036 C - - HORZ(TL):0.058 C - - Creep Factor: 2.0 Max TC CSI:0.963 Max BC CSI:0.719 Max Web CSI:0.933 VIEW Ver: 19.02.02B.0122.16 Job Number:T201946-REP Dsgnr:Shane Anders Truss Label:D4 Ply: 1 Qty:6 SEQN:165530 COMN FROM: Cust: R9073 JRef:1WVd90730015 T12 DrwNo:140.20.0736.39280 DW /BM 05/18/2020 TC2 w3 w4 w8 w9 28'8"4 9'7"4 7"8 6'8"6 6'8"6 13'5"8 6'9"2 19'5"8 6' 25'5"8 6' 32'0"4 6'6"12 38'11" 6'10"12 9'8"12 9'8"12 19'5"8 9'8"12 28'10"1 9'4"9 38'11" 10'0"151'3"1'3" 1'2"11'9"1412'0"3(a) (a)(a)(a)(a) (a) A B C D E F G H I JKLMNO 9.5 12 2X4 4X6 4X6 4X4 5X6 1.5X4 6X8 5X6 4X4 3X4 1.5X4 3X4 **WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAWING!**IMPORTANT**FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERSTrusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise,top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions. Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing,any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses.A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitabilityand use of this drawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2. For more information see this job's general notes page and these web sites: ALPINE: www.alpineitw.com; TPI: www.tpinst.org; SBCA: www.sbcindustry.com; ICC: www.iccsafe.org 2820 N. Great Southwest ParkwayGrand Prairie, TX 75050 Lumber Top chord: 2x4 SPF 1650f-1.5E;TC2 2x4 SPF #1/#2; Bot chord: 2x4 SPF 1650f-1.5E;Webs: 2x4 SPF #1/#2; w3,w9 2x3 SPF #3;w4 2x3 SPF #1/#2; w8 2x4 SPF 1650f-1.5E; Bracing (a) Continuous lateral restraint equally spaced onmember. Loading Bottom chord checked for 10.00 psf non-concurrent live load. Purlins In lieu of structural panels use purlins to brace all flatTC @ 24" oc. Wind Wind loads based on MWFRS with additional C&C member design. Right cantilever is exposed to wind Wind loading based on both gable and hip roof types. Maximum Reactions (lbs) Gravity Non-Gravity Loc R+/ R-/ Rh / Rw / U / RL N 1772 /-/-/802 /-/301 K 2695 /-/-/1005 /192 /- O 389 /-/-/291 /-/- Wind reactions based on MWFRS N Brg Width = 5.5 Min Req =2.8 K Brg Width = 5.5 Min Req =3.9 O Brg Width = 3.5 Min Req =1.5 Bearings N, K, & O Fcperp = 425psi. Members not listed have forces less than 375# Maximum Top Chord Forces Per Ply (lbs) Chords Tens.Comp. C - D 325 -1784 D - E 258 -942 Chords Tens.Comp. E - F 258 -942 F - G 692 -154 Maximum Bot Chord Forces Per Ply(lbs) Chords Tens.Comp. N - M 1429 -108M - L 1041 -51 Chords Tens.Comp. L - K 394 -106K - J 481 -266 Maximum Web Forces Per Ply(lbs) Webs Tens.Comp. B - N 197 -509 N - C 26 -1744 C - M 243 -441 M - D 637 -91 E - L 238 -660 Webs Tens.Comp. L - F 1298 -218 F - K 356 -2031 K - G 287 -638 H - J 197 -435 Loading Criteria (psf) TCLL:35.00 TCDL:10.00 BCLL:0.00 BCDL:10.00 Des Ld:55.00 NCBCLL:10.00 Soffit:0.00 Load Duration: 1.15 Spacing: 24.0 " Wind Criteria Wind Std:ASCE 7-16 Speed:115 mph Enclosure: Closed Risk Category: II EXP: C Kzt: NA Mean Height: 16.78 ft TCDL: 6.0 psf BCDL: 6.0 psf MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 3.89 ft Loc. from endwall: Any GCpi: 0.18 Wind Duration: 1.60 Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Code / Misc Criteria Bldg Code:IRC 2018 TPI Std:2014 Rep Fac: Yes FT/RT:16(0)/10(0) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL):0.066 M 999 240 VERT(CL):0.111 M 999 180 HORZ(LL):0.036 C - - HORZ(TL):0.058 C - - Creep Factor: 2.0 Max TC CSI:0.963 Max BC CSI:0.719 Max Web CSI:0.933 VIEW Ver: 19.02.02B.0122.16 Job Number:T201946-REP Dsgnr:Shane Anders Truss Label:D4 Ply: 1 Qty:6 SEQN:165530 COMN FROM: Cust: R9073 JRef:1WVd90730015 T12 DrwNo:140.20.0736.39280 DW /BM 05/18/2020 TC2 w3 w4 w8 w9 28'8"4 9'7"4 7"8 6'8"6 6'8"6 13'5"8 6'9"2 19'5"8 6' 25'5"8 6' 32'0"4 6'6"12 38'11" 6'10"12 9'8"12 9'8"12 19'5"8 9'8"12 28'10"1 9'4"9 38'11" 10'0"151'3"1'3" 1'2"11'9"1412'0"3(a) (a)(a)(a)(a) (a) A B C D E F G H I JKLMNO 9.5 12 2X4 4X6 4X6 4X4 5X6 1.5X4 6X8 5X6 4X4 3X4 1.5X4 3X4 05/19/2020 **WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAWING!**IMPORTANT**FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERSTrusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise,top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions. Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing,any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses.A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitabilityand use of this drawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2. For more information see this job's general notes page and these web sites: ALPINE: www.alpineitw.com; TPI: www.tpinst.org; SBCA: www.sbcindustry.com; ICC: www.iccsafe.org 2820 N. Great Southwest ParkwayGrand Prairie, TX 75050 Lumber Top chord: 2x4 SPF 1650f-1.5E;Bot chord: 2x4 SPF 1650f-1.5E; Webs: 2x4 SPF #1/#2; w2,w3,w13 2x3 SPF #3;w4,w5,w12 2x3 SPF #1/#2; Bracing (a) Continuous lateral restraint equally spaced on member. Loading Bottom chord checked for 10.00 psf non-concurrent live load. Purlins In lieu of structural panels use purlins to brace all flat TC @ 24" oc. Wind Wind loads based on MWFRS with additional C&Cmember design. Wind loading based on both gable and hip roof types. Condition:This Truss Label: D1 needs the interior bearing shifted left to 18-4-12as shown. All plates and joints shall be fully intact and undisturbed.Solution: Restore any original camber to the truss and support as necessary.Carefully cut and remove a portion of the truss not to disrupt theremaining plates in the remaining members as shown.Cut to fit and insert 2x4 SPF#1/#2-CAN webs as shown.Cut and apply 7/16" OSB APA Span Rated 24/16 Exposure 1gussets to each face of the truss using 0.113" x2.5" 8d boxnails at 2.0 inches on center staggered throughout all members.Size of gussets are indicated by height in inches x length in inches.Gussets are centered over the joint unless otherwise noted. If shownthe circled number indicates the minimum number of nails required on each face of each member. Apply nails per NDS requirements.Provide web bracing as shown. Maximum Reactions (lbs) Gravity Non-Gravity Loc R+/ R-/ Rh / Rw / U / RL R 1030 /-/-/457 /-/301 O 2619 /-/-/1062 /-/- K 1203 /-/-/583 /-/- Wind reactions based on MWFRS R Brg Width = 5.5 Min Req =1.6 O Brg Width = 5.5 Min Req =3.7 K Brg Width = 5.5 Min Req =1.9 Bearings R, O, & K Fcperp = 425psi. Members not listed have forces less than 375# Maximum Top Chord Forces Per Ply (lbs) Chords Tens.Comp. B - C 80 -996 C - D 175 -439 Chords Tens.Comp. G - H 215 -991 Maximum Bot Chord Forces Per Ply(lbs) Chords Tens.Comp. Q - P 647 -149M - L 375 -6 Chords Tens.Comp. L - K 838 0 Maximum Web Forces Per Ply(lbs) Webs Tens.Comp. B - R 88 -974 B - Q 562 0 C - P 137 -680 D - P 572 -20 D - O 37 -1021 O - S 232 -1618 E - S 151 -415 S - F 61 -917 Webs Tens.Comp. S - M 401 -26 F - M 624 0 M - G 85 -915 G - L 672 -39 L - H 186 -486 H - K 0 -1012 I - K 140 -435 Loading Criteria (psf) TCLL:35.00 TCDL:10.00 BCLL:0.00 BCDL:10.00 Des Ld:55.00 NCBCLL:10.00 Soffit:0.00 Load Duration: 1.15 Spacing: 24.0 " Wind Criteria Wind Std:ASCE 7-16 Speed:115 mph Enclosure: Closed Risk Category: II EXP: C Kzt: NA Mean Height: 16.78 ft TCDL: 6.0 psf BCDL: 6.0 psf MWFRS Parallel Dist: h to 2h C&C Dist a: 3.89 ft Loc. from endwall: not in 9.00 ft GCpi: 0.18 Wind Duration: 1.60 Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Code / Misc Criteria Bldg Code:IRC 2018 TPI Std:2014 Rep Fac: Yes FT/RT:16(0)/10(0) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL):0.040 L 999 240 VERT(CL):0.066 L 999 180 HORZ(LL):0.018 I - - HORZ(TL):0.029 I - - Creep Factor: 2.0 Max TC CSI:0.716 Max BC CSI:0.626 Max Web CSI:0.983 VIEW Ver: 20.01.00.0324.19 Job Number:T201946-REP Dsgnr:Shane Anders Truss Label:D1REP Ply: 1 Qty:7 SEQN:20866 COMN FROM: Cust: R9073 JRef:1WVd90730015 T21 DrwNo:139.20.1607.23863 DW /BM 05/18/2020 w2 w3 w4 w5 w12 w13 18'4"12 20'6"4 6'10"12 6'10"12 13'5"8 6'6"12 18'4"12 4'11"4 20'4"1 1'11"5 25'5"8 5'1"7 32'8"11 7'3"3 38'11" 6'2"5 6'8"4 6'8"4 13'5"8 6'9"4 18'3" 4'9"8 19'5"8 1'2"8 20'5"13 1'0"5 29'7"4 9'1"7 38'11" 9'3"121'3"1'3" 1'2"11'9"1412'0"3(a) (a)(a) (a) (a) (a) A B C D E F G H I J KLMNOPQR S 9.5 12 3X6 3X4 3X4 3X4 5X6 3X4 1.5X4 3X8 4X8 5X6 4X4 3X4 1.5X4 3X4 1212 12 8 8 14 814 22 8 8 12 14 2024"x30" Gusset 24"x30" Gusset 24"x42" Gusset 24"x16" Gusset 16"x24" Gusset 24"x16" Gusset **WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAWING!**IMPORTANT**FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERSTrusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise,top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions. Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing,any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses.A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitabilityand use of this drawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2. For more information see this job's general notes page and these web sites: ALPINE: www.alpineitw.com; TPI: www.tpinst.org; SBCA: www.sbcindustry.com; ICC: www.iccsafe.org 2820 N. Great Southwest ParkwayGrand Prairie, TX 75050 Lumber Top chord: 2x4 SPF 1650f-1.5E;Bot chord: 2x4 SPF 1650f-1.5E; Webs: 2x4 SPF #1/#2; w2,w3,w13 2x3 SPF #3;w4,w5,w12 2x3 SPF #1/#2; Bracing (a) Continuous lateral restraint equally spaced on member. Loading Bottom chord checked for 10.00 psf non-concurrent live load. Purlins In lieu of structural panels use purlins to brace all flat TC @ 24" oc. Wind Wind loads based on MWFRS with additional C&Cmember design. Wind loading based on both gable and hip roof types. Condition:This Truss Label: D1 needs the interior bearing shifted left to 18-4-12as shown. All plates and joints shall be fully intact and undisturbed.Solution: Restore any original camber to the truss and support as necessary.Carefully cut and remove a portion of the truss not to disrupt theremaining plates in the remaining members as shown.Cut to fit and insert 2x4 SPF#1/#2-CAN webs as shown.Cut and apply 7/16" OSB APA Span Rated 24/16 Exposure 1gussets to each face of the truss using 0.113" x2.5" 8d boxnails at 2.0 inches on center staggered throughout all members.Size of gussets are indicated by height in inches x length in inches.Gussets are centered over the joint unless otherwise noted. If shownthe circled number indicates the minimum number of nails required on each face of each member. Apply nails per NDS requirements.Provide web bracing as shown. Maximum Reactions (lbs) Gravity Non-Gravity Loc R+/ R-/ Rh / Rw / U / RL R 1030 /-/-/457 /-/301 O 2619 /-/-/1062 /-/- K 1203 /-/-/583 /-/- Wind reactions based on MWFRS R Brg Width = 5.5 Min Req =1.6 O Brg Width = 5.5 Min Req =3.7 K Brg Width = 5.5 Min Req =1.9 Bearings R, O, & K Fcperp = 425psi. Members not listed have forces less than 375# Maximum Top Chord Forces Per Ply (lbs) Chords Tens.Comp. B - C 80 -996 C - D 175 -439 Chords Tens.Comp. G - H 215 -991 Maximum Bot Chord Forces Per Ply(lbs) Chords Tens.Comp. Q - P 647 -149M - L 375 -6 Chords Tens.Comp. L - K 838 0 Maximum Web Forces Per Ply(lbs) Webs Tens.Comp. B - R 88 -974 B - Q 562 0 C - P 137 -680 D - P 572 -20 D - O 37 -1021 O - S 232 -1618 E - S 151 -415 S - F 61 -917 Webs Tens.Comp. S - M 401 -26 F - M 624 0 M - G 85 -915 G - L 672 -39 L - H 186 -486 H - K 0 -1012 I - K 140 -435 Loading Criteria (psf) TCLL:35.00 TCDL:10.00 BCLL:0.00 BCDL:10.00 Des Ld:55.00 NCBCLL:10.00 Soffit:0.00 Load Duration: 1.15 Spacing: 24.0 " Wind Criteria Wind Std:ASCE 7-16 Speed:115 mph Enclosure: Closed Risk Category: II EXP: C Kzt: NA Mean Height: 16.78 ft TCDL: 6.0 psf BCDL: 6.0 psf MWFRS Parallel Dist: h to 2h C&C Dist a: 3.89 ft Loc. from endwall: not in 9.00 ft GCpi: 0.18 Wind Duration: 1.60 Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Code / Misc Criteria Bldg Code:IRC 2018 TPI Std:2014 Rep Fac: Yes FT/RT:16(0)/10(0) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL):0.040 L 999 240 VERT(CL):0.066 L 999 180 HORZ(LL):0.018 I - - HORZ(TL):0.029 I - - Creep Factor: 2.0 Max TC CSI:0.716 Max BC CSI:0.626 Max Web CSI:0.983 VIEW Ver: 20.01.00.0324.19 Job Number:T201946-REP Dsgnr:Shane Anders Truss Label:D1REP Ply: 1 Qty:7 SEQN:20866 COMN FROM: Cust: R9073 JRef:1WVd90730015 T21 DrwNo:139.20.1607.23863 DW /BM 05/18/2020 w2 w3 w4 w5 w12 w13 18'4"12 20'6"4 6'10"12 6'10"12 13'5"8 6'6"12 18'4"12 4'11"4 20'4"1 1'11"5 25'5"8 5'1"7 32'8"11 7'3"3 38'11" 6'2"5 6'8"4 6'8"4 13'5"8 6'9"4 18'3" 4'9"8 19'5"8 1'2"8 20'5"13 1'0"5 29'7"4 9'1"7 38'11" 9'3"121'3"1'3" 1'2"11'9"1412'0"3(a) (a)(a) (a) (a) (a) A B C D E F G H I J KLMNOPQR S 9.5 12 3X6 3X4 3X4 3X4 5X6 3X4 1.5X4 3X8 4X8 5X6 4X4 3X4 1.5X4 3X4 1212 12 8 8 14 814 22 8 8 12 14 2024"x30" Gusset 24"x30" Gusset 24"x42" Gusset 24"x16" Gusset 16"x24" Gusset 24"x16" Gusset 05/19/2020 **WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAWING!**IMPORTANT**FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERSTrusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise,top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions. Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing,any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses.A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitabilityand use of this drawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2. For more information see this job's general notes page and these web sites: ALPINE: www.alpineitw.com; TPI: www.tpinst.org; SBCA: www.sbcindustry.com; ICC: www.iccsafe.org 2820 N. Great Southwest ParkwayGrand Prairie, TX 75050 Lumber Top chord: 2x4 SPF 1650f-1.5E;TC2 2x4 SPF #1/#2; Bot chord: 2x4 SPF 1650f-1.5E;Webs: 2x4 SPF #1/#2; w2,w3,w11 2x3 SPF #3;w5 2x4 SPF 1650f-1.5E; w9 2x3 SPF #1/#2; Bracing (a) Continuous lateral restraint equally spaced onmember. Loading Bottom chord checked for 10.00 psf non-concurrent live load. Purlins In lieu of structural panels use purlins to brace all flatTC @ 24" oc. Wind Wind loads based on MWFRS with additional C&C member design. Wind loading based on both gable and hip roof types. Condition:This Truss Label: D2 needs the interior bearing shifted right to 28-2-4as shown. All plates and joints shall be fully intact and undisturbed.Solution: Restore any original camber to the truss and support as necessary.Carefully cut and remove a portion of the truss not to disrupt theremaining plates in the remaining members as shown.Cut to fit and insert 2x4 SPF#1/#2-CAN web as shown.Cut and apply 7/16" OSB APA Span Rated 24/16 Exposure 1 gussets to each face of the truss using 0.113" x2.5" 8d boxnails at 2.0 inches on center staggered throughout all members.Size of gussets are indicated by height in inches x length in inches.Gussets are centered over the joint unless otherwise noted. If shownthe circled number indicates the minimum number of nails required on each face of each member. Apply nails per NDS requirements.Provide web bracing as shown. Maximum Reactions (lbs) Gravity Non-Gravity Loc R+/ R-/ Rh / Rw / U / RL P 1754 /-/-/782 /-/301 L 2224 /-/-/866 /-/- J 769 /-/-/411 /-/- Wind reactions based on MWFRS P Brg Width = 5.5 Min Req =2.8 L Brg Width = 5.5 Min Req =3.1 J Brg Width = 5.5 Min Req =1.5 Bearings P, L, & J Fcperp = 425psi. Members not listed have forces less than 375# Maximum Top Chord Forces Per Ply (lbs) Chords Tens.Comp. B - C 192 -1991 C - D 307 -1681 Chords Tens.Comp. D - E 290 -908 E - F 290 -908 Maximum Bot Chord Forces Per Ply(lbs) Chords Tens.Comp. O - N 1439 -75 Chords Tens.Comp. N - M 1022 -24 Maximum Web Forces Per Ply(lbs) Webs Tens.Comp. B - P 171 -1693B - O 1357 -28 C - N 129 -483 N - D 544 -25 M - F 1184 -145 Webs Tens.Comp. E - M 240 -653F - L 178 -2074 F - K 598 -45 K - G 207 -596 H - J 148 -484 Loading Criteria (psf) TCLL:35.00 TCDL:10.00 BCLL:0.00 BCDL:10.00 Des Ld:55.00 NCBCLL:10.00 Soffit:0.00 Load Duration: 1.15 Spacing: 24.0 " Wind Criteria Wind Std:ASCE 7-16 Speed:115 mph Enclosure: Closed Risk Category: II EXP: C Kzt: NA Mean Height: 16.78 ft TCDL: 6.0 psf BCDL: 6.0 psf MWFRS Parallel Dist: h to 2h C&C Dist a: 3.89 ft Loc. from endwall: not in 9.00 ft GCpi: 0.18 Wind Duration: 1.60 Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Code / Misc Criteria Bldg Code:IRC 2018 TPI Std:2014 Rep Fac: Yes FT/RT:16(0)/10(0) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL):0.068 N 999 240 VERT(CL):0.108 N 999 180 HORZ(LL):0.023 C - - HORZ(TL):0.038 C - - Creep Factor: 2.0 Max TC CSI:0.736 Max BC CSI:0.531 Max Web CSI:0.951 VIEW Ver: 20.01.00.0324.19 Job Number:T201946-REP Dsgnr:Shane Anders Truss Label:D2REP Ply: 1 Qty:8 SEQN:20870 COMN FROM: Cust: R9073 JRef:1WVd90730015 T22 DrwNo:140.20.0759.45007 DW /BM 05/18/2020 TC2 w2 w3 w5 w9 w11 28'2"4 10'8"12 6'4"15 6'4"15 13'5"8 7'0"9 19'5"8 6' 25'5"8 6' 32'2"10 6'9"2 38'11" 6'8"6 6'2"7 6'2"7 10'8"12 4'6"5 19'5"8 8'8"12 28'2"4 8'8"12 29'2"4 1' 38'11" 9'8"121'3"1'3" 1'2"11'9"1412'0"3(a)(a)(a) (a) (a) (a) A B C D E F G H I JKLMNOP 9.5 12 4X4 2X4 3X4 3X4 4X4 5X6 1.5X4 6X8 5X6 4X4 4X6 2X4 4X6 9 9 106 4 12 12 11 11 18 18 18 12 12 12 12 12 10 10 24"x18" Gusset 12"x18" Gusset 28"x24" Gusset 18"x30" Gusset 36"x32" Gusset **WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAWING!**IMPORTANT**FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERSTrusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise,top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions. Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing,any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses.A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitabilityand use of this drawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2. For more information see this job's general notes page and these web sites: ALPINE: www.alpineitw.com; TPI: www.tpinst.org; SBCA: www.sbcindustry.com; ICC: www.iccsafe.org 2820 N. Great Southwest ParkwayGrand Prairie, TX 75050 Lumber Top chord: 2x4 SPF 1650f-1.5E;TC2 2x4 SPF #1/#2; Bot chord: 2x4 SPF 1650f-1.5E;Webs: 2x4 SPF #1/#2; w2,w3,w11 2x3 SPF #3;w5 2x4 SPF 1650f-1.5E; w9 2x3 SPF #1/#2; Bracing (a) Continuous lateral restraint equally spaced onmember. Loading Bottom chord checked for 10.00 psf non-concurrent live load. Purlins In lieu of structural panels use purlins to brace all flatTC @ 24" oc. Wind Wind loads based on MWFRS with additional C&C member design. Wind loading based on both gable and hip roof types. Condition:This Truss Label: D2 needs the interior bearing shifted right to 28-2-4as shown. All plates and joints shall be fully intact and undisturbed.Solution: Restore any original camber to the truss and support as necessary.Carefully cut and remove a portion of the truss not to disrupt theremaining plates in the remaining members as shown.Cut to fit and insert 2x4 SPF#1/#2-CAN web as shown.Cut and apply 7/16" OSB APA Span Rated 24/16 Exposure 1 gussets to each face of the truss using 0.113" x2.5" 8d boxnails at 2.0 inches on center staggered throughout all members.Size of gussets are indicated by height in inches x length in inches.Gussets are centered over the joint unless otherwise noted. If shownthe circled number indicates the minimum number of nails required on each face of each member. Apply nails per NDS requirements.Provide web bracing as shown. Maximum Reactions (lbs) Gravity Non-Gravity Loc R+/ R-/ Rh / Rw / U / RL P 1754 /-/-/782 /-/301 L 2224 /-/-/866 /-/- J 769 /-/-/411 /-/- Wind reactions based on MWFRS P Brg Width = 5.5 Min Req =2.8 L Brg Width = 5.5 Min Req =3.1 J Brg Width = 5.5 Min Req =1.5 Bearings P, L, & J Fcperp = 425psi. Members not listed have forces less than 375# Maximum Top Chord Forces Per Ply (lbs) Chords Tens.Comp. B - C 192 -1991 C - D 307 -1681 Chords Tens.Comp. D - E 290 -908 E - F 290 -908 Maximum Bot Chord Forces Per Ply(lbs) Chords Tens.Comp. O - N 1439 -75 Chords Tens.Comp. N - M 1022 -24 Maximum Web Forces Per Ply(lbs) Webs Tens.Comp. B - P 171 -1693B - O 1357 -28 C - N 129 -483 N - D 544 -25 M - F 1184 -145 Webs Tens.Comp. E - M 240 -653F - L 178 -2074 F - K 598 -45 K - G 207 -596 H - J 148 -484 Loading Criteria (psf) TCLL:35.00 TCDL:10.00 BCLL:0.00 BCDL:10.00 Des Ld:55.00 NCBCLL:10.00 Soffit:0.00 Load Duration: 1.15 Spacing: 24.0 " Wind Criteria Wind Std:ASCE 7-16 Speed:115 mph Enclosure: Closed Risk Category: II EXP: C Kzt: NA Mean Height: 16.78 ft TCDL: 6.0 psf BCDL: 6.0 psf MWFRS Parallel Dist: h to 2h C&C Dist a: 3.89 ft Loc. from endwall: not in 9.00 ft GCpi: 0.18 Wind Duration: 1.60 Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Code / Misc Criteria Bldg Code:IRC 2018 TPI Std:2014 Rep Fac: Yes FT/RT:16(0)/10(0) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL):0.068 N 999 240 VERT(CL):0.108 N 999 180 HORZ(LL):0.023 C - - HORZ(TL):0.038 C - - Creep Factor: 2.0 Max TC CSI:0.736 Max BC CSI:0.531 Max Web CSI:0.951 VIEW Ver: 20.01.00.0324.19 Job Number:T201946-REP Dsgnr:Shane Anders Truss Label:D2REP Ply: 1 Qty:8 SEQN:20870 COMN FROM: Cust: R9073 JRef:1WVd90730015 T22 DrwNo:140.20.0759.45007 DW /BM 05/18/2020 TC2 w2 w3 w5 w9 w11 28'2"4 10'8"12 6'4"15 6'4"15 13'5"8 7'0"9 19'5"8 6' 25'5"8 6' 32'2"10 6'9"2 38'11" 6'8"6 6'2"7 6'2"7 10'8"12 4'6"5 19'5"8 8'8"12 28'2"4 8'8"12 29'2"4 1' 38'11" 9'8"121'3"1'3" 1'2"11'9"1412'0"3(a)(a)(a) (a) (a) (a) A B C D E F G H I JKLMNOP 9.5 12 4X4 2X4 3X4 3X4 4X4 5X6 1.5X4 6X8 5X6 4X4 4X6 2X4 4X6 9 9 106 4 12 12 11 11 18 18 18 12 12 12 12 12 10 10 24"x18" Gusset 12"x18" Gusset 28"x24" Gusset 18"x30" Gusset 36"x32" Gusset 05/19/2020 **WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAWING!**IMPORTANT**FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERSTrusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise,top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions. Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing,any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses.A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitabilityand use of this drawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2. For more information see this job's general notes page and these web sites: ALPINE: www.alpineitw.com; TPI: www.tpinst.org; SBCA: www.sbcindustry.com; ICC: www.iccsafe.org 2820 N. Great Southwest ParkwayGrand Prairie, TX 75050 Lumber Top chord: 2x4 SPF 1650f-1.5E;TC2 2x4 SPF #1/#2; Bot chord: 2x4 SPF 1650f-1.5E;Webs: 2x4 SPF #1/#2; w4 2x3 SPF Stud;w10 2x4 SPF 1650f-1.5E; w11 2x3 SPF #3; Bracing (a) Continuous lateral restraint equally spaced onmember. Loading Bottom chord checked for 10.00 psf non-concurrent live load. Purlins In lieu of structural panels use purlins to brace all flatTC @ 24" oc. Wind Wind loads based on MWFRS with additional C&C member design. Right cantilever is exposed to wind Wind loading based on both gable and hip roof types. Condition:This Truss Label: D4 needs the interior bearing shifted left to 9-7-4as shown. All plates and joints shall be fully intact and undisturbed.Solution:Restore any original camber to the truss and support as necessary. Carefully cut and remove a portion of two webs not to disrupt theremaining plates in the remaining members as shown.Cut to fit and insert 2x4 SPF#1/#2-CAN webs as shown.Cut and apply 7/16" OSB APA Span Rated 24/16 Exposure 1gussets to each face of the truss using 0.113" x2.5" 8d box nails at 2.0 inches on center staggered throughout all members.Size of gussets are indicated by height in inches x length in inches.Gussets are centered over the joint unless otherwise noted. If shownthe circled number indicates the minimum number of nails requiredon each face of each member. Apply nails per NDS requirements.Provide web bracing as shown. Maximum Reactions (lbs) Gravity Non-Gravity Loc R+/ R-/ Rh / Rw / U / RL P 615 /-/-/240 /-/301 O 2295 /-/-/1021 /72 /- L 1854 /-/-/861 /26 /- Wind reactions based on MWFRS P Brg Width = 5.5 Min Req =1.5 O Brg Width = 5.5 Min Req =3.2 L Brg Width = 3.5 Min Req =2.5 Bearings P, O, & L Fcperp = 425psi. Members not listed have forces less than 375# Maximum Top Chord Forces Per Ply (lbs) Chords Tens.Comp. E - F 329 -947 F - G 329 -946 Chords Tens.Comp. G - H 375 -1650 Maximum Bot Chord Forces Per Ply(lbs) Chords Tens.Comp. O - N 440 -60N - M 999 0 Chords Tens.Comp. M - L 1277 -54 Maximum Web Forces Per Ply(lbs) Webs Tens.Comp. B - P 207 -500 C - O 209 -478 O - E 124 -1484 E - N 1101 -153 Webs Tens.Comp. F - N 240 -665 G - M 476 -74 H - L 423 -2030 I - K 207 -430 Loading Criteria (psf) TCLL:35.00 TCDL:10.00 BCLL:0.00 BCDL:10.00 Des Ld:55.00 NCBCLL:10.00 Soffit:0.00 Load Duration: 1.15 Spacing: 24.0 " Wind Criteria Wind Std:ASCE 7-16 Speed:115 mph Enclosure: Closed Risk Category: II EXP: C Kzt: NA Mean Height: 16.78 ft TCDL: 6.0 psf BCDL: 6.0 psf MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 3.89 ft Loc. from endwall: Any GCpi: 0.18 Wind Duration: 1.60 Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Code / Misc Criteria Bldg Code:IRC 2018 TPI Std:2014 Rep Fac: Yes FT/RT:16(0)/10(0) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL):0.057 M 999 240 VERT(CL):0.093 M 999 180 HORZ(LL):0.024 L - - HORZ(TL):0.041 L - - Creep Factor: 2.0 Max TC CSI:0.683 Max BC CSI:0.652 Max Web CSI:1.000 VIEW Ver: 20.01.00.0324.19 Job Number:T201946-REP Dsgnr:Shane Anders Truss Label:D4REP Ply: 1 Qty:6 SEQN:20886 COMN FROM: Cust: R9073 JRef:1WVd90730015 T23 DrwNo:140.20.0916.03350 DW /BM 05/18/2020 E 5X6 O w4 C4X6 5 5 TC2 w3 w4 w10 w11 9'7"4 28'8"4 7"8 6'8"6 6'8"6 9'7" 2'10"10 13'5"8 3'10"8 19'5"8 6' 25'5"8 6' 32'0"4 6'6"12 38'11" 6'10"12 9'7" 9'7" 19'5"8 9'10"8 28'10"1 9'4"9 38'0"14 9'2"13 38'11" 10"2 1'3" 1'3" 1'2"11'9"1412'0"3(a) (a) (a)(a)(a)(a) (a) (a) A B C D E F G H I J KLMNOP 9.5 12 2X4 4X6 4X6 1.5X4 6X8 5X6 4X4 3X4 1.5X4 3X4 5X6 2X3 Web 2X4 WebTrim Plate 12"x12" Gusset 24"x24" Gusset 24"x36" Gusset 24"x30" Gusset 16"x30" Gusset16"x16" Gusset 5 5 5 10 14 14 11 14 14 20 5 5 5 5 10 18 18 18 20 **WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAWING!**IMPORTANT**FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERSTrusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise,top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions. Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing,any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses.A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitabilityand use of this drawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2. For more information see this job's general notes page and these web sites: ALPINE: www.alpineitw.com; TPI: www.tpinst.org; SBCA: www.sbcindustry.com; ICC: www.iccsafe.org 2820 N. Great Southwest ParkwayGrand Prairie, TX 75050 Lumber Top chord: 2x4 SPF 1650f-1.5E;TC2 2x4 SPF #1/#2; Bot chord: 2x4 SPF 1650f-1.5E;Webs: 2x4 SPF #1/#2; w4 2x3 SPF Stud;w10 2x4 SPF 1650f-1.5E; w11 2x3 SPF #3; Bracing (a) Continuous lateral restraint equally spaced onmember. Loading Bottom chord checked for 10.00 psf non-concurrent live load. Purlins In lieu of structural panels use purlins to brace all flatTC @ 24" oc. Wind Wind loads based on MWFRS with additional C&C member design. Right cantilever is exposed to wind Wind loading based on both gable and hip roof types. Condition:This Truss Label: D4 needs the interior bearing shifted left to 9-7-4as shown. All plates and joints shall be fully intact and undisturbed.Solution:Restore any original camber to the truss and support as necessary. Carefully cut and remove a portion of two webs not to disrupt theremaining plates in the remaining members as shown.Cut to fit and insert 2x4 SPF#1/#2-CAN webs as shown.Cut and apply 7/16" OSB APA Span Rated 24/16 Exposure 1gussets to each face of the truss using 0.113" x2.5" 8d box nails at 2.0 inches on center staggered throughout all members.Size of gussets are indicated by height in inches x length in inches.Gussets are centered over the joint unless otherwise noted. If shownthe circled number indicates the minimum number of nails requiredon each face of each member. Apply nails per NDS requirements.Provide web bracing as shown. Maximum Reactions (lbs) Gravity Non-Gravity Loc R+/ R-/ Rh / Rw / U / RL P 615 /-/-/240 /-/301 O 2295 /-/-/1021 /72 /- L 1854 /-/-/861 /26 /- Wind reactions based on MWFRS P Brg Width = 5.5 Min Req =1.5 O Brg Width = 5.5 Min Req =3.2 L Brg Width = 3.5 Min Req =2.5 Bearings P, O, & L Fcperp = 425psi. Members not listed have forces less than 375# Maximum Top Chord Forces Per Ply (lbs) Chords Tens.Comp. E - F 329 -947 F - G 329 -946 Chords Tens.Comp. G - H 375 -1650 Maximum Bot Chord Forces Per Ply(lbs) Chords Tens.Comp. O - N 440 -60N - M 999 0 Chords Tens.Comp. M - L 1277 -54 Maximum Web Forces Per Ply(lbs) Webs Tens.Comp. B - P 207 -500 C - O 209 -478 O - E 124 -1484 E - N 1101 -153 Webs Tens.Comp. F - N 240 -665 G - M 476 -74 H - L 423 -2030 I - K 207 -430 Loading Criteria (psf) TCLL:35.00 TCDL:10.00 BCLL:0.00 BCDL:10.00 Des Ld:55.00 NCBCLL:10.00 Soffit:0.00 Load Duration: 1.15 Spacing: 24.0 " Wind Criteria Wind Std:ASCE 7-16 Speed:115 mph Enclosure: Closed Risk Category: II EXP: C Kzt: NA Mean Height: 16.78 ft TCDL: 6.0 psf BCDL: 6.0 psf MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 3.89 ft Loc. from endwall: Any GCpi: 0.18 Wind Duration: 1.60 Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Code / Misc Criteria Bldg Code:IRC 2018 TPI Std:2014 Rep Fac: Yes FT/RT:16(0)/10(0) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL):0.057 M 999 240 VERT(CL):0.093 M 999 180 HORZ(LL):0.024 L - - HORZ(TL):0.041 L - - Creep Factor: 2.0 Max TC CSI:0.683 Max BC CSI:0.652 Max Web CSI:1.000 VIEW Ver: 20.01.00.0324.19 Job Number:T201946-REP Dsgnr:Shane Anders Truss Label:D4REP Ply: 1 Qty:6 SEQN:20886 COMN FROM: Cust: R9073 JRef:1WVd90730015 T23 DrwNo:140.20.0916.03350 DW /BM 05/18/2020 E 5X6 O w4 C4X6 5 5 TC2 w3 w4 w10 w11 9'7"4 28'8"4 7"8 6'8"6 6'8"6 9'7" 2'10"10 13'5"8 3'10"8 19'5"8 6' 25'5"8 6' 32'0"4 6'6"12 38'11" 6'10"12 9'7" 9'7" 19'5"8 9'10"8 28'10"1 9'4"9 38'0"14 9'2"13 38'11" 10"2 1'3" 1'3" 1'2"11'9"1412'0"3(a) (a) (a)(a)(a)(a) (a) (a) A B C D E F G H I J KLMNOP 9.5 12 2X4 4X6 4X6 1.5X4 6X8 5X6 4X4 3X4 1.5X4 3X4 5X6 2X3 Web 2X4 WebTrim Plate 12"x12" Gusset 24"x24" Gusset 24"x36" Gusset 24"x30" Gusset 16"x30" Gusset16"x16" Gusset 5 5 5 10 14 14 11 14 14 20 5 5 5 5 10 18 18 18 20 05/19/2020 13723 Riverport Drive Suite 200 Maryland Heights, MO 63043 05/19/2020 13723 Riverport Drive Suite 200 Maryland Heights, MO 63043 05/19/2020