Loading...
HomeMy WebLinkAboutLA178847 8630 188th St W Permit PackRESIDENTIAL BUILDING PERMIT APPLICATION PAGE 2 OFFICE USE ONLY BUILDING PERMIT TYPE REQUIRED INSPECTIONS SINGLE FAMILY DWELLING BUILDING DUPLEX AS BUILT TOWNHOUSE UNITS BUILDING FINAL DETACHED TOWN HOUSE UNIT DECK FOOTING CONDO FIREPLACE ACESSORY BUILDING FOOTING REROOF FOUNDATION RESIDE FRAMING PORCH FRAMING GARAGES INSULATION RES ADDN/REPAIR/RMDL DECK PORCH GARAGES LATH LOWER LEVEL FINISH LOWER LEVEL FINAL ADDITION OTHER FOUNDATION ONLY PORCH FOOTING MISCELLANEOUS POURED WALL DEMO SEPTIC TANK REMOVAL MOVED SITE MECHANICAL CITY BUILDING VALUATION: $AIR TEST FINAL BUILDING PERMIT FEES ROUGH-IN $PERMIT FEE PLUMBING $PLAN CHECK FINAL $SURCHARGE ROUGH-IN $METRO SAC METER SIZE $CITY WATER HOOKUP UNIT PRESSURE REDUCING VALVE $CITY SEWER HOOKUP UNIT SEWER/WATER $LANDSCAPE ESCROW SEWER/WATER $TREE ESCROW FINAL $MISC ESCROW STREET DRAINTILE $PLUMBING BUILDING INFORMATION $MECHANICAL TYPE OF CONSTRUCTION $SEWER WATER ZONING $OTHER CODE EDITION $TOTAL FIRE SUPPRESSION SYSTEM OCCUPANCY GROUP APPROVED BY: BUILDING INSPECTOR: Date: PLUMBING/MECHANICAL INSPECTOR: Date: COMMENTS: 20195 Holyoke Avenue, Lakeville, MN 55044 952-985-4400  952-985-4499 fax www.lakevillemn.gov Sewer & Water Tie Card Address:________________________________________ Contractor:______________________________________ Permit Number:__________________________________ Final Date:________________ Street Drain-Tile:______ Size of Water Service: 1” Comments: AIRTEST SANITARY OVER 20’/2 FITTINGS THIS CARD MUST BE COMPLETED AND ON-SITE AT TIME OF SEWER & WATER INSPECTION These plans, and the concept thereofor used without written consent. And may not be reproducedare the exclusive property of D.R. Horton Inc.,COPYRIGHT D.R. HORTON, INC. 2014CROOF PLAN1/8"=1'-0"128126XXXXXADDRESS NUMBERSTEEL PANEL OVERHEAD DOOR4:12 PITCH6:12 PITCHDDAAA10 1/8" HEEL 7 7/16"HEEL1'-4"1'-4"ELEVATION CD1x6-1/4" FROM TOP OF THRESHOLDTO TOP OF JOIST6 1/4"AHEARTLAND COTTAGEBKT7x12x4FYPONDTYPICAL3 1/2" TRIMAT FRONT ONLY1/2"=1'-0"TYPICAL WDW & DOOR TRIM3 1/2" TRIM 5" TRIM5" TRIM1"DETAIL1/4"=1'-0"PORCH COLUMN128128HARDBOARD TRIMHARD BOARD SIDINGHARD BOARD SIDING2-SIDED OUTSIDE CORNER2-3/4" .96"3-1/2"SHEATHINGHDBD TRIM1-SIDED OUTSIDE CORNER3-1/2"HARD BOARD SIDINGVINYL SIDING"J" CHANNELHARDBOARD TRIM2X6 CAP2X6 BASE8X8 REALWOOD COLUMN4X4 REALWOODANGLED BRACKET2X6 CAP2X6 BASE8X8 REALWOOD COLUMN4X4 REALWOODANGLED BRACKET8" TRIM8" TRIM1.0X20860 KENBRIDGE COURT, SUITE 100LAKEVILLE, MN 55044 (952)985-72725490-C-3.1GRANTDRAWN: 10-5-2015-AWREVISED: 7-30-2018-AWSPEC HOMECUST:RAIN DIVERTERLIGHT FIXTURES1/2"=1'-0"BLOCKING AT7-1/4"12" 4"4" DIA. HOLEREFSIDING LEGENDALAP SIDING "B"LAP SIDING "A"PRODUCTCBD5" TRIM - VINYL LINEALNOT USEDE6 1/2" VINYL BEAD BDE6:126:128:128:124:126:126:12AAAABBBBCCCC35' RIDGE VENT15' RIDGE VENT 19' RIDGE VENT 8:128:12PERMIT/CONST: 3-31-2020-CF8630 188TH ST WPERMIT/CONST.PLANSLOT 2, BLK 2CHOKECHERRY HILL 5TH ADD.REAR ELEVATION1/8"=1'-0"RIGHT ELEVATION1/8"=1'-0"LEFT ELEVATION1/8"=1'-0"42" MIN BELOW FINISHED GRADEALL EXTERIOR FTGS TO BEMAINTAIN 6" MIN SEPARATION WOOD to EARTH1'-4"8:12 PITCHA1267 7/16" HEEL 1267 7/16"HEEL1'-4"A5 3/4" HEEL1'-7"1'-0"6:12 PITCH124A8:12 PITCH8:12 PITCHA1x CEDAR6:12 PITCH1'-0"42" MIN BELOW FINISHED GRADEALL EXTERIOR FTGS TO BE1'-0"1'-0"6:12 PITCHASPHALT SHINGLESFLASH OVER ALL EXT OPGS12812840% TO 50% NEAR RIDGEVENT 1/300th OF ROOF AREAREMAINDER IN SOFFITPER IRC SECTION R806.2AASecure door closed until deck isconstructed with a separate permit.Concept Approval ONLYSubject to Field InspectionInspectorDate2015MN BldgCode04/17/2020dmathews These plans, and the concept thereofor used without written consent. And may not be reproducedare the exclusive property of D.R. Horton Inc.,COPYRIGHT D.R. HORTON, INC. 2014C2.0XDRAWN: 10-5-2015-AWGRANT 5490-C-3.1PC#763: 7-23-2019-LLPC#637: 9-3-2019-CFPC#666: 9-19-2019-CFBASEMENT PLAN1/4"=1'-0"UNEXCAVATEDUP16R50'-0" 31'-0" 18'-0"13'-0" 19'-0" 50'-0"18'-0"8'-0"22'-0"26'-0"29'-6"18'-0"5'-0"29'-0"R/I3/4B62 SQ. FT.2-82-4DROPPED BEAMUNFINISHEDSTORAGE16'-3" M.O.6" CURB (OMIT CURB AT GARAGE DOOR OPENINGS)6" THICK16"x8" FTG.POURED CONC. WALLMIN. 3'-6" BELOW GRADE8'-3" M.O.2 ANCHOR STRAPS WITHMIN. UPLIFT CAPACITY OF 4,200 LBS.1'-7 1/2"16'-3"1'-7 1/2"8'-3"1'-1 1/2"6" CURB, 2" LEDGEPOURED CONC. WALL16"x8" CONC. FTG.8" THICKMIN. 3'-6" BELOW GRADE6" CURB, 2" LEDGEPOURED CONC. WALL16"x8" CONC. FTG.8" THICK, 8'-4" HIGH9'-6"19'-6"16"x8" CONC. FTG.POURED CONC. WALL8" THICK, 8'-4" HIGHPOURED CONC. WALL16"x8" CONC. FTG.8" THICK, 8'-4" HIGH16"x8" CONC. FTG.POURED CONC. WALL8" THICK, 8'-4" HIGHSILLCOCK3'-0"FUTUREBEDRM211 SQ. FT.2-61-65-014'-0"33'-0"15'-6"2'-6"8'-8"2'-4"16"x8" CONC. FTG.POURED CONC. WALL8" THICK, 8'-4" HIGH9'-7 1/2"7'-2 1/2"9'-1 3/4"11'-1 3/4"12'-0" 3'-6"2'-6"TYP. WINDOW HEAD HEIGHT AT 6'-11 3/8" U.N.O.NOTE:8'-4" HIGH POURED CONC. FOUNDATION WALL TYPICALWDW SIZES GIVEN IN FEET AND INCHES (WIDTH x HEIGHT)BEAM & HEADER SIZES TO BE VERIFIED BY SUPPLIER/MFRFUTUREFAMILY RM698 SQ. FT.6'-1 1/2"2x6 BRNG WALL30x30x12CONC. PAD FTG.30x30x12CONC. PAD FTG.6" CURB, 2" LEDGEPOURED CONC. WALL16"x8" CONC. FTG.8" THICKMIN. 3'-6" BELOW GRADEUNFINISHEDMECH.2-64'-2 1/8"3'-3 5/8"3 1/2"7'-9 1/4"18" MFD FLOOR TRUSSESINSTALL PER MFRS SPECS 2x6 BEARING WALL2x6 STUDS AT 16" O.C.6" HALF HIGH CONC. CURB14x8 CONC. FTG.SUMPACWHF.D.NOTE:MECHANICAL EQUIPMENT LAYOUT WILL VARYPER PLUMBING, ELECTRICAL, MECHANICAL,STRUCTURAL AND/OR SITE CONDITIONSA/CHV12" FTG VOIDFOR PLUMBINGRADONVENT PIPE34x48FBGL SHWR24" TOWEL BAR7 1/2"2 ANCHOR STRAPS WITHMIN. UPLIFT CAPACITY OF 4,200 LBS.2'-0" TPH36"NOTE: ROCK WHOLELOWER LEVEL CEILINGEXCEPT FOR 80 SQ FTAT MECHANICAL ROOM1/2"=1'-0"PORCH SKIRT DETAIL1/2"=1'-0"FRONT PORCH LEDGER SECTION1x10 CEDAR SKIRTAT DROPPED BEAM1x10 CEDAR SKIRTAT DECK RIM JOISTBLOCKING AS REQ.FOR SKIRT SUPPORTDROPPED BEAMUSP LTS19-TZ BRACKETON WOOD BLOCKING6 1/4"7 1/4"6 3/4"FLASHING ABOVEDOORTHRESHOLDGRADETOP OF SUBFLOORTO TOP OF JOIST6-1/4" FROM1 1/2"AND BELOW 2x8 &2x10 TRTD LEDGERSTRTD 2X8 JOISTS16" O.C.(8) 10d COMMON NAILSTRTD. 2X10 RIPPED(TOP OF FOUND TOBOTTOM OF DECK JOIST)5/4" DECKINGRIM BOARD1-1/8" OSB18" FLOOR TRUSSES(4) PER DECK, RATED AT 750 # EACHSPACED EVENLY, MAX. 24" FROM END OF LEDGERLATERAL LOAD CONNECTION:USP LTS19-TZ w/ LBP12-TZ WASHERUSP 1/2" DIAM LAG SCREWMIN. 3" PENETRATION INTO OSB RIM AND FLOOR TRUSS(GALV. OR STAINLESS STEEL)2-86'-0"3'-0"47'-0"17'-6"7'-9"6'-10"10'-5"6x6 TREATED POST16"X60" CONC. PIERMIN. 3'-6" BELOW GRADE3"TREATED 2x8's 16" ON CENTER 3"CANT. JOISTS7'-5"8"7'-2"CANT. JOISTSPOURED CONC. WALL18"x8" CONC. FTG.8" THICKMIN. 3'-6" BELOW GRADE(2) 2x10 DROPPED BEAM(2) 2x10 DROPPED BEAM3'-0"16'-6"BRACINGFOUNDATIONSYSTEMBRACINGFOUNDATIONSYSTEMFULL/LO BSMTBRACING ATFOUND.FBSFULL/LO BSMTBRACING ATFOUND.4'-0"FBSMAX.FOUNDATION INSULATIONFRONT FOUNDATION WALL:-23 SQ FT/52 LIN FT= 0.44 RATIOR-10REAR FOUNDATION WALL:-24 SQ FT/47 LIN FT= 0.51 RATIORIGHT SIDE FOUND. WALL:-51 SQ FT/26 LIN FT= 1.96+ RATIOLEFT SIDE FOUND. WALL:-53 SQ FT/31 LIN FT= 1.71 RATIO-FOUNDATION INSULATIONRATINGS ARE BASED ONLESS THAN 2.6 AIR CHANGESPER HOUR DURING THE AIRLEAKAGE TESTR-10R-15R-15REQUIREMENTS1/2"=1'-0"FRONT PORCH LEDGER DETAIL18" FLOOR TRUSSES 3/4" 1st FLOOR WALLSSUBFLOOR 9'-1 1/8" BASEMENT WALLS 3/4" SUBFLOOR6 1/4"7-1/4"2x8 PORCHLEDGER2x6 EXTERIOR WALL. 2""MIN...5 1/4" 2" FROM TOPLAG SCREW TO BEMIN. 2" FROM EDGE16" O.C. UNDER 10'-0" SPAN12" O.C. OVER 10'-0" SPANSUBFLOOR TOTOP OF LEDGEROF LEDGER19.2" O.C.FLOOR TRUSSESBLOCKING, LAID FLAT(2) TRTD 2x12(8) 16D NAILS ON INSIDEBLOCKING, LAID FLATTRTD (2) 2x12(8) 16D NAILS PER SIDE(8) 30D NAILS ON OUTSIDELAG SCREWS1/2" DIAMETERINSTALLED STAGGERED IN 2 ROWSLAG SCREWS W/ WASHER TO BEUSP LTS19-TZ STRAPS TO BE ATTACHED TO DECK JOISTOR 2X12 BLOCKING AND ANCHORED INTO FLOOR TRUSS.(4) STRAPS PER DECK/PORCH, RATED AT 750# EACH,TO BE SPACED EVENLY. MAX 24" FROM END OF DECK LEDGERMINIMUM 3" PENETRATION THRU OSB RIM & FLOOR TRUSS12" FTG VOIDFOR PLUMBINGGROUNDING RODTHRU PLATES7'-0"47'-0"21'-6"9'-0"5036 SLIDER5036 SLIDER5036 SLIDER9'-6"2x6 LOOKOUT WALL2x6 STUDS AT 16" O.C. POURED CONC. WALLTREATED BOTTOM PLATE18x8 CONC. FTG.8" THICK, 3'-6" HIGHCOCKSILL8630 188TH ST WPERMIT/CONST.PLANSLOT 2, BLK 2CHOKECHERRY HILL 5TH ADD.WINDOW & DOOR SCHEDULE-LOOKOUTCALL-OUTU-FACTORROUGH OPENINGLOCATIONSHGC#5036 SLIDER0.2960" X 42"BEDROOM0.3215036 SLIDER0.2960" X 42"FAMILY RM.0.322PLAN OPTIONSLOOKOUT BASEMENT(2)9-1/2 Versa-Lam(2)9-1/2 Versa-Lam(2)9-1/2 Versa-Lam(2)7-1/4 Versa-LamUFER Ground-Provide 20' Rebar in footing and stubup near electrical service panel. GARAGE1ST FLOOR PLAN1/4"=1'-0"GREATROOMDINETTESTUDY1/2BOWNERSENTRY47'-0"50'-0" 31'-0" 18'-0"13'-0" 19'-0" 50'-0"13'-7 1/4"6'-0"24'-0"26'-0"17'-6"19'-6"6"18'-0"11'-0"7'-0"5'-0"9'-6"10'-10"6'-0"29'-0"47'-0"12'-0"16'-6"12'-5 1/2"6'-0 1/2"9'-9"9'-9"4'-9"5'-8"5'-4"3'-4"3'-8"3W 3050 SHThese plans, and the concept thereofor used without written consent. And may not be reproducedare the exclusive property of D.R. Horton Inc.,COPYRIGHT D.R. HORTON, INC. 2014C3.0XDRAWN: 10-5-2015-AWGRANT 5490-C-3.1PC#763: 7-23-2019-LLPC#637: 9-3-2019-CFPC#666: 9-19-2019-CF3040 SHSUBFLOOR TO43 1/2" FROM TOP OFSET KITCHEN WINDOWSRGH.OPG. OF WINDOW8'-0"4'-2"2'-8"9'-8 1/2"6'-9 1/2"8'-8"2'-3"DROPPED HDRFLUSH HDR2x6 BRNG WALLSLOPE TO DOORS4" CONC FLOORON ALL WALLS & CEILINGGYP. BOARDNOTE: 686 SQ. FT.16x7 OVERHEAD DOOR8x7 OVERHEAD DOOR8'-0"2W 3050 SH3-0SL2x6 BRNG WALL2-8PED.CPT.HD-FLRHD-FLRHD-FLRCPT.CPT.HD-FLRFOYERHD-FLR10" OVERHANG 24"x72"BASE22x30ATTICACCESS 9'-8 1/2"1312 SQ. FT.NOTE:9'-1 1/8" PLATE HEIGHT TYPICALWDW SIZES GIVEN IN FEET AND INCHES (WIDTH x HEIGHT)TYP. FIRST FLOOR WINDOW HEAD HEIGHT AT 7'-11 3/8" U.N.O.BEAM & HEADER SIZES TO BE VERIFIED BY SUPPLIER/MFR3'-6"2'-0"3'-6"3'-0"42" HIGH HALF WALLW/ WOOD CAPUP16RDN16RBOOT BENCH& COAT RACKS2'-8"5-022'-0"2'-4"10'-0"3'-0" 4'-2 1/8"3'-3 5/8"7'-9 1/4"3 1/2"WOOD PORCH10'-5"3"3"TYPICAL PORCH COLUMN:7'-9"6'-10"12" WIDE DROPPED SOFFIT(SEE SECTION)140 SQ. FT.COVEREDDROPPED BEAM(2) 2-6 DOOR2'-3"2-04'-8"6'-4 3/4"2'-3"2-0RADONVENT PIPE14" MFD I-JOISTSINSTALL PER MFRS SPECS6'-6"DROP HEADER HGT AT PORCHNOTE:8" FROM HOUSE PLATES5'-3"10'-0"2-42'-0"DROPPED HDRCANT.BEAM8x8 MFD COLUMN W/2x6 CAP & BASE AND4x4 ANGLED BRACE22'-0"2'-0"TPH 24" TOWEL BAR42" HIGH 2X6 1/2 WALLW/ WOOD CAPNOTE: FINISHSTAIRWAY DOWN TOBOTTOM STEPSET HEAD HEIGHT AT 6'-11 3/8"14" TRANSOM6068 SGD W/2'-0"8'-6 1/2"3'-7 1/4"3'-7"WINDOW & DOOR SCHEDULECALL-OUTU-FACTORROUGH OPENINGLOCATIONSHGC#3-0 DOOR W/ SL0.3153 3/4" X 83 1/4"FOYER0.2312W 3050 SHSTUDY13W 3050 SHGREAT ROOM13040 SHKITCHEN16068 SGD W/ TRANS.DINETTE10.310.3172 1/8" X 60 1/4"0.31108" X 60 1/4"0.310.3172 1/8" X 94"0.320.3136 1/4" X 48"0.313'-0"3'-0"KIT.REF.SINKDWHD-FLR20 AMP.MICRO HOODCIRCUITGASCOOKTOPINSTALL STACKEDKITCHEN BACKSPLASHTO OUTSIDEVENT MICROHOOD GAS FP R.O. 42" X 40-1/8" FRAME-TO-FRAME 5'-1 5/8"7'-0"5'-1 5/8" INSIDE FRAMING INSIDE FRAMING 8630 188TH ST WPERMIT/CONST.PLANSLOT 2, BLK 2CHOKECHERRY HILL 5TH ADD.PLAN OPTIONSGAS FIREPLACESIGNATURE KITCHENSTUDY ROOMBOOT BENCH WITH COAT RACK5'-0 1/4"2'-0"6555555PFHPFH3.52.555(2)9-1/2 Versa-Lam(2)11-7/8 Versa-Lam(2)14" Versa-Lam(2)7-1/4 Versa-Lam(2)7-1/4 Versa-Lam(2)7-1/4 Versa-Lam(2)11-7/8 Versa-Lam(2)9-1/2 Versa-Lam(2)7-1/4 Versa-Lam(1)14" Versa-Lam 1241 SQ. FT.2ND FLOOR PLAN1/4"=1'-0"LIVING AREAThese plans, and the concept thereofor used without written consent. And may not be reproducedare the exclusive property of D.R. Horton Inc.,COPYRIGHT D.R. HORTON, INC. 2014C4.0XDRAWN: 10-5-2015-AWGRANT 5490-C-3.1PC#763: 7-23-2019-LLPC#637: 9-3-2019-CFPC#666: 9-19-2019-CFNOTE:8'-1 1/8" PLATE HEIGHT TYPICALWDW SIZES GIVEN IN FEET AND INCHES (WIDTH x HEIGHT)TYP. SECOND FLOOR WINDOW HEAD HEIGHT AT 6'-11 3/8" U.N.O.BEAM & HEADER SIZES TO BE VERIFIED BY SUPPLIER/MFRCENTER OF SHWR HEAD OPG 84" ABOVE SUBFLOOR OWNERS BATH W/1/2"=1'-0"SHOWER BASEFIBERGLASS BASE18"DETAIL 'A'36X60 FIBERGLASSCL16" @ 34" SHWR4'-0"CLSHOWERCONTROLTO CENTER OF SHOWER VALVE SEATS & TOE LEDGES 10-3/4"36"VALVE17-3/16" @ 36" SHWROWNERSBEDRMBEDRM #2BEDRM #447'-0"5'-0"31'-0" 12'-10"6'-6"11'-8" 31'-0"5'-0"26'-0"18'-0"29'-0"47'-0"9'-6"7'-6"12'-0"14'-3"3'-7 7/8"3'-10 7/8"5'-4"5'-8"6'-2"9'-0"CPT.CPT.CPT.5'-2"4'-4"3050 SH2W 3050 SH3020 FXTPHGIRDER TRUSSMFD TRUSSES AT 24" O.C.DN16R11'-9"2'-6"11'-9"3'-11 3/4"7'-9 1/4"11'-0"2'-6"2x6 WALLWDLAU.HD-FLR2-85-0TUB/SHWR2x6 WALL11'-6"2'-9"BEDRM #3CPT.24" TOWEL BARBATH#2HD-FLR2-466"OWNERSBATHHD-FLRW.I.C.2-6CPT.5-05-01-61'-11 1/2"3'-6"8'-6"2-62-69'-3 7/8"9'-6"2'-3"3050 SH42" HIGH HALF WALLW/ WOOD CAP42" HIGH HALF WALLW/ WOOD CAP3020 FX5'-7"6'-5"RADONVENT PIPE2x6 WALL10'-11 1/4"22x30ATTICACCESSMFD TRUSSES AT 24" O.C.10'-0"9'-4"4-072"17'-6 3/4"3050 SH3050 SH10'-0"TPH 2-42-42-42-67'-5 1/4"3'-6"8 3/4"16'-6 1/4"15'-2"2'-10"3'-6"11'-8"2'-4 1/8"5'-1"2'-7 1/2"8'-0"6'-3"3'-0"7'-11 1/4"2040 SHTEMP. GL.24" TOWEL BAR 2'-3"2040 SHTEMP. GL.WINDOW & DOOR SCHEDULE- UPPER LEVELCALL-OUTU-FACTORROUGH OPENINGLOCATIONSHGC#OWNERS BDRM23050 SH3050 SHBEDRM #213050 SHBEDRM #312W 3050 SHBEDRM #412040 SHOWNER'S BATH2BEDRM #313020 FXSTAIRWAY13020 FX0.310.3172 1/8" X 60 1/4"0.3136 1/4" X 60 1/4"0.310.3136 1/4" X 60 1/4"0.310.3136 1/4" X 60 1/4"0.310.3124" X 48"0.3136 1/4" X 24"0.310.336 1/4" X 24"0.310.34'-4"NOTES:ALL TOE LEDGES AND SEATSARE 18" OFF THE SUBFLOORBATOE LEDGES ARE MODEL BT-17BY BETTER BENCH SYSTEMSHEIGHT OF SHOWER SHELVES TO BEDEPENDENT ON TILE SELECTIONSMIXER VALVE IS ALWAYSCENTERED BELOW SHOWER HEADCDTHIS DETAIL REFLECTS MODEL #'s,HEIGHTS & LOCATIONS ONLY, ANDDOES REFLECT QUANTITIES PURCHASEDREFER TO DEC SELECTIONS FORSTD & OPTIONAL INCLUDED FEATURES3'-9"42x60 FBGL TUBPROVIDE ACCESS6" SPLASHW/ 36" GLASS PANEL2x4 WALL, 48" HIGHW/ CT SURROUND34x60 FBGL BASETOELEDGESHWRSHELVES8630 188TH ST WPERMIT/CONST.PLANSLOT 2, BLK 2CHOKECHERRY HILL 5TH ADD.PLAN OPTIONSTILED SHOWER SURROUND2ND SINK IN BATH #2-Min. 15" clearance to anyobstruction from center ofW.C., 24" in front(typ). These plans, and the concept thereofor used without written consent. And may not be reproducedare the exclusive property of D.R. Horton Inc.,COPYRIGHT D.R. HORTON, INC. 2014C5.0XDRAWN: 10-5-2015-AWGRANT 5490-C-3.1PC#763: 7-23-2019-LLPC#637: 9-3-2019-CFPC#666: 9-19-2019-CF1/4"=1'-0"SUMPACWHF.D.A/CHVRADONVENT PIPE15 AMP CIRCUITFOR POWER VENTW/ SINGLE RECEPTACLEELECTRICAL PLANBASEMENTSEPERATE 15 AMP CIRCUITW/ SINGLE RECEPTACLEGFIWPSDSSR/I3/4BUNEXCAVATEDUNFINISHEDSTORAGEFUTUREBEDRMFUTUREFAMILY RMUNFINISHEDMECH.LOW VOLTAGESYSTEM RECEPTACLESMART HOMESYSTEM RECEPTACLEWATER SOFTRECEPTACLE8630 188TH ST WPERMIT/CONST.PLANSLOT 2, BLK 2CHOKECHERRY HILL 5TH ADD.PLAN OPTIONSLOOKOUT BASEMENT GARAGEELECTRICAL PLAN1/4"=1'-0"GREATROOMDINETTEKIT.STUDY1/2BOWNERSENTRYThese plans, and the concept thereofor used without written consent. And may not be reproducedare the exclusive property of D.R. Horton Inc.,COPYRIGHT D.R. HORTON, INC. 2014C6.0XDRAWN: 10-5-2015-AWGRANT 5490-C-3.1PC#763: 7-23-2019-LLPC#637: 9-3-2019-CFPC#666: 9-19-2019-CFFOYERWOOD PORCHCOVEREDC1ST FLOORRADONVENT PIPESPRINKLERSYSTEMRECEPTACLESGFISS SSSSSFANGFI SSWP S TCHIMESDSSSSSWPELECTRICAL PLAN1/4"=1'-0"RADONVENT PIPE2ND FLOORCEILING FANSSSS GFIGFISSSSSSSS SGFIFANSD/CMDSD/CMDSDSDSDSDLOWNERSBEDRMBEDRM #2BEDRM #4BEDRM #3BATH#2OWNERSBATHW.I.C.SSFANC ROUGH-INSLLLLLLFANS SHCPGFISS2nd SMARTHOME RECEPTDLLLLLDDDDLLLLLLDLLSSSDISP.USBLS PEND.PEND.3'-0"9'-6"7'-1 5/8"S LLLLLLSTECH TUBECD 8630 188TH ST WPERMIT/CONST.PLANSLOT 2, BLK 2CHOKECHERRY HILL 5TH ADD.PLAN OPTIONSGAS FIREPLACESIGNATURE KITCHENSTUDY ROOMBOOT BENCH WITH COAT RACKKITCHEN PENDANT LIGHTINGDINETTE LIGHTINGGREAT ROOM LIGHTINGTILED SHOWER SURROUND2ND SINK IN BATH #2 These plans, and the concept thereofor used without written consent. And may not be reproducedare the exclusive property of D.R. Horton Inc.,COPYRIGHT D.R. HORTON, INC. 2014C7.0XDRAWN: 10-5-2015-AWGRANT 5490-C-3.1PC#763: 7-23-2019-LLPC#637: 9-3-2019-CFPC#666: 9-19-2019-CF9'-1 1/8"10'-3 7/8"9'-8 3/4"8'-2"8'-1 1/8"MFD TRUSS1'-4"1267 7/16" GIRDER TRUSS COVEREDWOOD PORCH8'-0"6 1/4"STUDYGREATROOMFUTUREFAMILY RMUNFINISHEDSTORAGEBEDRM #45'-0"26'-0"31'-0"CROSS SECTION B-B1/4"=1'-0"OWNERSBEDRMDROPPED BEAM1'-7"7'-9"5 3/4" HEEL124DROP HEADER HGT AT PORCHNOTE:8" FROM HOUSE PLATES8"18" MFD FLOOR TRUSSES3/4" 250 SUBFLOOR14" MFD I-JOISTS3/4" 350 SUBFLOOR8'-4" POUREDCONC WALL3 1/2" CONC. FLOOR2x8 JOISTS5/4" DECKING(2) 2x10DROPPED BEAMTOP OF THRESHOLDTO TOP OF JOIST6-1/4" FROM3"DROPPED SOFFITVERIFY DEPTHPER BEAM SIZE12" WIDE1'-0"9'-1 1/8" 10'-3 7/8"8'-4" POUREDCONC WALL3 1/2" CONC. FLOOR9'-8 3/4" 8'-2"8'-1 1/8"MFD TRUSS1'-4"1267 7/16"DINETTE4" CONC. FLOORGARAGECROSS SECTION A-A1/4"=1'-0"OWNER'SBATHW.I.C.18" MFD FLOOR TRUSSES3/4" SUBFLOOR14" MFD I-JOISTS3/4" SUBFLOOR1'-4"7 7/16"2x10 JOISTS2x10 JOISTSPOURED CONC. WALL18"x8" CONC. FTG.8" THICKMIN. 3'-6" BELOW GRADESET ON 10" THICKPOURED CONC. WALLCONC. SIDEWALKCANT.JOISTS5'-0" These plans, and the concept thereofor used without written consent. And may not be reproducedare the exclusive property of D.R. Horton Inc.,COPYRIGHT D.R. HORTON, INC. 2014C8.0XDRAWN: 10-5-2015-AWGRANT 5490-C-3.1PC#763: 7-23-2019-LLPC#637: 9-3-2019-CFPC#666: 9-19-2019-CFATTIC VENTILATIONROOF AREA: 1333 SQ. FT.319.92 NET FREE VENT NEEDED AT RIDGE50' (LIN. FT. RIDGE VENT) X 18 SQ. IN. (PER LIN. FT) = 900 PROVIDEDFULLY VENTED SOFFITSVENT 1/300th OF ROOF AREA50% TO 80% NEAR RIDGEREMAINDER IN SOFFITPER IRC SECTION R806319.92 NET FREE VENT NEEDED AT SOFFITGARAGE: 687 SQ. FT.164.88 NET FREE VENT NEEDED AT RIDGE19' (LIN. FT. RIDGE VENT) X 18 SQ. IN. (PER LIN. FT) = 342 PROVIDEDFULLY VENTED SOFFITS164.88 NET FREE VENT NEEDED AT SOFFITHAND RAIL ALL STAIRSPROVIDE MIN. 6'-8" HEADROOM3) LSL STRINGERS7 3/4" MAX RISE10" TREAD CUTSTAIR DATA9'-1 1/8"10'-3 7/8"9'-8 3/4"8'-2"8'-1 1/8"6'-8"MIN HEADROOM6'-8"MIN HEADROOM BEDRM #4LAU.STUDYUNFINISHEDMECH.OWNERSENTRY1/2BUNFINISHEDSTORAGECROSS SECTION C-C1/4"=1'-0"BEDRM #318" MFD FLOOR TRUSSES3/4" 250 SUBFLOOR14" MFD I-JOISTS3/4" 350 SUBFLOOR8'-4" POUREDCONC WALL3 1/2" CONC. FLOORTHE SLOPING OF THE FLOORBE PROTECTED WHEREVER4" CONC. GARAGE FLOORRIGID INSULATION MUSTCREATES AN EXPOSURE.GARAGE SLAB LEDGE DETAIL5/8" GYP. BD.1/2" SHEATHINGMIN. R-20 INSULATION2x6 STUDS AT 16" O.C.HOUSE WRAPSIDING PER ELEV.BARRIER PASTACOUSTICAL SEALANTEXTEND POLY VAPOR1-1/2" THERMAX2-1/4"X12" DUCTINSULATION(R-10 x 2)1/2"=1'-0"WALL DETAIL1/2"=1'-0"TYPICAL WALL SECTION1/2"=1'-0"9'-1 1/8"TRUSSES PER PLAN3/4" SUBFLOORVARIESSEE PLANVARIES122x6 STUDS AT 16" O.C.BLOCK AT MIDPOINT2x6 BEARING WALL14x8 CONC. FTG.6" HALF HIGH CONC. CURB. BLK.1/2" ANCHOR BOLTSOMIT BEARING WALLAT STEEL OR LVL BEAMR-49 INSUL.MFD TRUSSESA I R C HU T E S APPLIED ON WARM-IN-WINTER SIDE OFTHERMAL INSULATION AT ABOVE GRADEFRAMED WALLS, RIM JOISTS, FLRS AND CLGSNOTEDUNLESSOTHERWISENOTEDUNLESSOTHERWISEOVER 1/2" SHEATHINGSHINGLES OVER FELT PAPERRIGID WIND WASH INSTALLED EXTENDINGBARRIER MUST BETO WITHIN 1-1/2" to 2"FROM BOTTOM OFROOF SHEATHING4 MIL. POLY VAPOR / AIR BARRIERALUMINUMCORNICEVENTS40% TO 50% NEAR RIDGEVENT 1/300th OF ROOF AREAREMAINDER IN SOFFITPER IRC SECTION R806EXT. SPRAY-ON WATERPROOFINGWATCH DOG + ENERGY SYSTEMTREATED SILL PLATEAPPROVED ANCHORPER CODE (IRC R403.1.6)16x8 CONC. FTG.RUN INTO SUMP BASKETCONTINUOUS DRAIN TILEWHERE APPLICABLETREATEDSILL PLATEVERTICAL REINFORCINGAS SOIL COND. REQUIREW/ SILL SEALERMIN. 42" BELOW FINISHED GRADEALL EXTERIOR FOOTINGS TO BE4" INCH CLEAN AGGREGATE ORCONCRETE SLAB AND PREPARED SUBGRADE6 MIL POLY V.B. W/ LAPPED SEAMS 12" BETWEENAPPROVED GAS-PERMEABLE LAYERPASSIVE SUB-SLAB DEPRESSURIZATIONSYSTEM REQUIRED PER MINNESOTARESIDENTIAL ENERGY CODE 1322.2100POURED CONC. WALL8" THICK, 8'-4" HIGH2x6 LOOKOUT WALL2x6 STUDS AT 16" O.C.ANCHOR BOLTS AT 6' O.C.8" THICK, 42" HIGHPOURED CONC. WALL16x8 CONC. FTG.TREATED BOTTOM PLATE2x6 WALKOUT WALL2x6 STUDS AT 16" O.C.ANCHOR BOLTS AT 6' O.C.POURED CONC. WALL(6" CURB, 2" INT. LEDGE)16x8 CONC. FTG.TREATED BOTTOM PLATE8" THICK, 42" HIGHOPENINGS, JOINTS AND SUMPSFOUNDATION WALL & SLABSEAL JOINT BETWEEN3-1/2" CONC. FLOOR SEALED AT8'-1 1/8"1/2" EXT. SHEATHING5-1/2" BATT INSULATION2x6 STUDS AT 16" O.C. W/HOUSE WRAPSIDING PER ELEV.JOISTS PER PLAN3/4" SUBFLOORSEE PLANVERTICAL CLEARANCE OF NOT LESS THANTHE EXTERIOR WALL TOP PLATETO THE ROOF SHEATHINGSIX INCHES FROM THE OUTSIDE EDGE OF6" MIN. HEEL 6'-0" OF ICE & WATER SHIELDINSTALL PER MFR'S SPECSTERMINATE 12" ABOVE ROOF2x6 SUBFASCIASEALANT BY CARPENTERPRIOR TO SHEATHINGPROVIDE RECEPTACLE FOR FUTURE RADON FANVENT PIPE SHALL BE INSTALLED WITH A MINIMUM24" HORIZONTAL CLEARANCE AND 36" VERTICALCLEARANCE TO ALLOW FOR FUTURE INSTALLATIONOF RADON FAN (ACTIVE SYSTEM)W/ VAPOR BARR.5/8" GYP. BD.APPLIED ON WARM-IN-WINTER SIDE OFTHERMAL INSULATION AT ABOVE GRADEFRAMED WALLS, RIM JOISTS, FLRS AND CLGS4 MIL. POLY VAPOR / AIR BARRIERW/ APPROVED SEALANTGYP. BD. W/ VAPOR BARR.1/2" SAG-RESISTANT1/2" GYP. BD.SEAL BEHIND POLY.SEAL BEHIND POLY.1/2" GYP. BD.SEAL BEHIND POLY.SEAL BEHIND POLY.PASSIVE RADON VENTLABEL ON EACH FLR"RADON REDUCTION SYSTEM"PASSIVE RADON VENTLABEL ON EACH FLR"RADON REDUCTION SYSTEM"PASSIVE RADON VENTLABEL ON EACH FLR"RADON REDUCTION SYSTEM"TO EACH SIDE OF "T" FITTING IN AGGREGATE10' SECTION OF PERFORATED PIPE CONNECTED1/2" OSB or 1/2" TREATED PLYWDAT GROUND LEVEL APPLICANTIONSTO MAINTAIN PERMANENT CONTACTWITH THE UNDERSIDE OFTHE SUBFLOOR DECKINGFLASHING OVER XPINSULATION. XP TO RUNMIN. 6" BELOW GRADEFINISHED GRADEWILL VARYJOIST CANTILEVER DETAIL(R-30.5) (STC - 41)5" MIN. POLYURETHANE FOAM2x6 EXTERIOR WALL(SEE OSWELL ENGINEERING)R-0.62R-21R-N/AR-N/AINSIDE AIR FILMR-0.681/2" GYP BD.R-0.45OUTSIDE AIR FILMR-0.171/2" EXT. SHEATHING5-1/2" BATT INSULATION2x6 STUDS AT 16" O.C. W/HOUSE WRAPSIDING PER ELEV.R-0.62R-21R-N/AR-N/AINSIDE AIR FILMR-0.681/2" GYP BD.R-0.45OUTSIDE AIR FILMR-0.172x6 EXTERIOR WALL3.5" MIN. POLYURETHANE FOAMAT PERIMETER R=203.5" MIN. POLYURETHANE FOAMAT PERIMETER R=20GYP. BD. EXCEPT 80 SF AT1/2" SAG-RESISTANTRUNNING THRU UNCONDITIONEDSPACES TO HAVER-4 INSUL. (MIN)VENT PIPER-10 RIGID INSULATIONINTENDED FOR EXTERIOR USEASTM C578, C612 or C1029INSTALLED PER MFR'S SPECSALL NON-BEARING PARTITION WALLSTO BE FRAMED AT 16" ON CENTERALL NON-BEARING PARTITION WALLSTO BE FRAMED AT 16" ON CENTER5000 PSI TESTED -OR-APPROVED ADMIXTURETHE MECHANICAL ROOMOF FOUNDATION WALL16x8 CONC. FTG.5000 PSI TESTED -OR-APPROVED ADMIXTURE(IF REQUIRED PER FOUNDATIONEXTEND OVER SILL PLATER-5 RIGID INSULATION(AT RIGHT AND LEFT SIDEOF HOME ONLY)SEALED AND TAPED AT TOPCALCULATIONS, R402.2.8.A)R-5 RIGID INSULATION(AT SIDE LOOKOUT FOUNDATION ONLY,NOT AT REAR LOOKOUT WALLS)R-5 RIGID INSULATION-ON INSIDETAPE & SEAL AT TOPFLASHING OVER XPINSULATION. XP TO RUNMIN. 6" BELOW GRADEDRAINTILE AT WALKOUT WALLS(HILLCREST ONLY)W/ R-10 DRAINAGE BOARDROLL-ON WATERPROOFINGWALL EDGE, ACROSS THE TOP, ANDEXTEND FROM TOP INTERIOR6" DOWN THE EXTERIOR WALL FACE2x10 JOISTS2x10 JOISTSLIGHT FIXTURES1/2"=1'-0"BLOCKING AT7-1/4"12" 4"4" DIA. HOLE14" TO TOP OFSTONE VENEER 1"=1'-0"WALL DETAILLOOKOUT FINISH2x6 TREATEDSILL PLATE1x6SILL PLATE2x4 INTERIORWALL2x_ TREATEDBLOCKING1/2" GYP. BD.1/2" GYP BD LEDGE6-1/2" CAP BOARDSHOE PERIMETERWINDOW FRAMEEXTERIOR SHEATHINGR-10 EXTERIORINSULATIONR-5 INTERIORINSULATION (IFREQ'D PER CODE)1/2"=1'-0"FLOOR DETAILDENSE PACK FIBERGLASS3/4" SUBFLOOR6" ROUND DUCTWORKMANUFACTURED I-JOISTSR-8 INSULATION WRAPNETR-30 SPRAY FOAM INSUL.4.34" AROUND DUCTWORK(R-6.9 PER INCH)BLOWN-IN INSULATION1" CLOSED-CELLSPRAY FOAM5/8" GYP. BD. FOUNDATION DETAILAT FOOTING STEP LOCATIONS1F1DescriptionDateRevisionProject Number:Date:F11Sheets: of2Print Name:Signed: License Number:Nick Hanson46665Date:I hereby certify that this plan, specification or reportwas prepared by me or under my direct supervisionand that I am a duly Licensed Professional Engineerunder the laws of the State of Minnesota.January 1, 20200.0011-1-202020 FOUNDATION GUIDEWALL SECTIONWALKOUT WALL CONDITION2F1WALL SECTIONLOOKOUT WALL CONDITION3F1WALL SECTIONEXTERIOR UNBALANCED FILLCONDITION4F1WALL SECTIONFULL HEIGHT WALL CONDITION5F1REBAR TABLE6F1SITE ADDRESS:City:State:Zip:MNCOPYRIGHT HANSON GROUP LLC 2020©3407 Kilmer Lane NorthSuite 4Plymouth, MN 55441Tel 612-708-3572www.hansongroupmn.comDRAWING USE GUIDELINES AND LIMITATIONSTHE CONTRACTOR LISTED IN THE TITLE BLOCK BELOW IS LICENSED BY THE HANSON GROUP TO USE THISPACKET WITHIN THESE LIMITATIONS NOTED FOR PROJECTS WHICH THE LICENSEE IS DIRECTLY RESPONSIBLE.THE LICENSEE MAY RELEASE THIS PACKET TO ITS SUB-CONTRACTORS AND CLIENTS FOR USE IN THEPROCUREMENT OF BUILDING PERMITS FOR PROJECTS WHICH THE LICENSEE IS USING THESE DRAWINGS.THE FOUNDATION GUIDELINES ARE TO BE ISSUED TO THE APPROPRIATE BUILDING DEPARTMENT INACCORDANCE WITH THEIR APPROVED PROCEDURE FOR USE BY THE BUILDING AGENCY DURING PLAN REVIEWAND INSPECTIONS.LIMITATIONS1.BASEMENT FOUNDATION WALLS TEN FOOT OR LESS IN CLEAR HEIGHT (FROM TOP OF FLOOR SLAB TO TOPOF CONCRETE WALL AT SILL PLATE BEARING-NOT NECESSARILY BASEMENT CEILING HEIGHT).2.STRUCTURE HEIGHT IS NOT TO EXCEED TWO STORIES ABOVE THE BASEMENT.3.OVERALL BUILDING IS ASSUMED TO FALL WITHIN THE PRESCRIPTIVE LIMITATIONS OF THE CODE. A SITESPECIFIC PLAN REVIEW HAS NOT BEEN PERFORMED.4.STRUCTURES CONSTRUCTED OF WOOD FLOOR, WOOD ROOF, AND WOOD WALLS ONLY. NO PRECAST ORSTRUCTURAL CONCRETE BEARING ON FOUNDATION WALLS IS PERMITTED.5.EXTERIOR GRADE SLOPING DOWN AND AWAY FROM THE FOUNDATION WALLS.6.ANY CASE BEYOND THE ABOVE NOTED ITEMS REQUIRES SEPARATE AND SPECIFIC STRUCTURALENGINEERING DOCUMENTS.COLD WEATHER GUIDELINES:1.THE CONTRACTOR AND CONCRETE SUPPLIER ARE TO WORK TO OBTAIN A MIX DESIGN WHICH WILLADEQUATELY PERFORM UNDER THE EXPECTED CONSTRUCTION CONDITIONS. THE USE OF ADDITIONALCEMENT, HIGH-EARLY STRENGTH CONCRETE, AND/OR ACCELERATOR IS RECOMMENDED ATTEMPERATURES AND CONDITIONS EXPECTED LESS THAN TWENTY DEGREES F.2.DELIVER CONCRETE WARM AND IN A TIMELY MANNER. PLACE CONCRETE EARLY IN THE DAY WHENPOSSIBLE.3.DO NOT ADD ADDITIONAL WATER TO THE CONCRETE. THE USE OF WATER REDUCING AGENTS ISRECOMMENDED WHEN WORKABILITY CONCERNS EXIST. NO CONCRETE IS TO BE PLACED ON SNOW OR INCONTACT WITH FROZEN MATERIALS.4.REBAR DOES NOT NEED TO BE PRE-HEATED, BUT IS TO BE FREE OF FROST, SNOW, AND ICE.5.BLANKETS OR OTHER ACCEPTED PROTECTION IS HIGHLY RECOMMENDED FOR THE TOP 24" OF THE WALLSWHEN THE AIR TEMPERATURE IS LESS THAN TEN DEGREES F AND FOR THE FULL HEIGHT OF THE WALLWHEN THE AIR TEMPERATURE IS LESS THAN ZERO DEGREES F.**THE ABOVE COLD WEATHER GUIDELINES ARE GENERAL RECOMMENDATIONS AND ALL ACI COLD WEATHERREQUIREMENTS ARE TO BE FOLLOWED AT THE RESPONSIBILITY OF THE LICENSEE.MATERIALSCONCRETE WALLS:F'c = 3000 PSI @ 28 DAYSMIX DESIGN AND PROPORTIONED BY CONCRETE SUPPLIERCONCRETE FOOTINGS:F'c = 5000 PSI @ 28 DAYS (OR 3000 PSI WITH AN APPROVED ADMIXTURE THAT PROVIDESA WATER AND VAPOR RESISTANCE AT LEAST OR EQUIVALENT TO 5000 PSI CONCRETE.AGGREGATE: FOOTINGS - 1 12" MAX. WALLS/SLABS - 34" MAX.REINFORCING STEEL: #4- BARS - ASTM A615 GRADE 40#5+ BARS - ASTM A615 GRADE 60TREATED SILL PLATE:SYP GRADE #2 OR BETTERALLOWABLE SOILBEARING PRESSURE1,500 PSF MINIMUMGENERAL NOTES1.DO NOT BACKFILL BASEMENT WALLS UNTIL THE CONCRETE HAS REACHED A MINIMUM COMPRESSIVESTRENGTH OF 2,250 PSI. IN ADDITION, DO NOT BACKFILL UNTIL THE BASEMENT WALLS ARE LATERALLYSUPPORTED BY THE FINAL INSTALLED FLOOR CONSTRUCTION AT THE TOP AND BOTTOM, UNLESSADEQUATE SHORING IS INSTALLED AS REQUIRED. SHORING IS THE SOLE RESPONSIBILITY OF THE GENERALCONTRACTOR.2.STRIP FOOTING MAY BE PLACED AT ELEVATIONS LOWER THAN SHOWN IN THE DETAILS.3.112" DEEP BY 312" WIDE BY CONTINUOUS KEYWAYS MAY BE USED IN LIEU OF DOWELS FOR FULL HEIGHT ANDFROST WALLS.4.STRIP FOOTING TO WALL CENTERLINES MAY BE OFFSET UP TO 2", HOWEVER, A MINIMUM OF 2" OF STRIPFOOTING IS TO EXTEND BEYOND THE WALL FACE ON EACH SIDE.5.PROVIDE CODE REQUIRED FROST PROTECTION TO THE BOTTOM OF ALL FOOTINGS.6.SLOPE GRADE DOWN AND AWAY FROM THE STRUCTURE A MINIMUM OF 6" WITHIN THE FIRST TEN FEETUNLESS ADEQUATE DRAINAGE OR SWALES ARE PROVIDED.7.BOTH MATERIALS AND INSTALLATION OF DRAIN TILE, WATER-PROOFING, CONTROL JOINTS, FLASHING, ANDINSULATION ARE TO BE IN ACCORDANCE WITH THE CODE BY THE GENERAL CONTRACTOR, UNLESS NOTEDOTHERWISE.8.ALL WALL WIDTHS SHOWN ARE NOMINAL DIMENSIONS, UNLESS NOTED OTHERWISE. OVERALL WALLTHICKNESS MAY VARY BY UP TO 12" FROM THAT SHOWN ON THE DRAWINGS.9.REINFORCING PLACEMENT TOLERANCE IS NOT TO EXCEED 12". BARS BEING SPLICED ARE TO BE WITHIN 2"OF CENTERLINE. MINIMUM SPLICE LENGTHS ARE 30 BAR DIAMETERS FOR GRADE 40 STEEL AND 48 BARDIAMETERS FOR GRADE 60 STEEL. TYING IS NOT REQUIRED PROVIDED THESE TOLERANCES ARE MET.10.PROVIDE MATCHING HOOK BARS FOR ALL HORIZONTAL BARS AT WALL CORNERS AND INTERSECTIONS.HORIZONTAL BARS MAY BE PLACED ANYWHERE WITHIN THE WALL AS LONG AS A 2" MINIMUM CLEAR COVERIS ACHIEVED ON ALL SIDES.11.REINFORCING MAY BE BUNDLED UP TO A MAXIMUM OF THREE BARS.12.DOWELS MAY BE DRILLED AND GROUTED IN PLACE. VERTICAL BARS AND DOWELS DO NOT NEED TO ALIGN.VERTICAL BARS MAY BE DRILLED AND EMBEDDED 5" INTO THE STRIP FOOTING IN LIEU OF DOWELS.13.THE BOND BETWEEN CONCRETE AND REINFORCING WILL NOT BE APPRECIABLY REDUCED IF VERY MINORFORM OIL IS PRESENT FOR THE CONDITIONS CONTAINED WITHIN THESE DRAWINGS.14.SILL PLATES ARE TO BE ANCHORED WITH A MINIMUM OF TWO ANCHORS PER SILL SECTION. ALL SECTIONSARE TO HAVE AN ANCHOR WITHIN 4" TO 12" OF EACH END. AN ANCHOR IS TO BE PLACED AT ALL WALLCORNERS AND INTERSECTIONS ON WALLS MORE THAN TWO FEET IN LENGTH. WALLS TWO FEET OR LESS INLENGTH REQUIRE A MINIMUM OF ONE ANCHOR. REQUIREMENTS FOR SHEAR WALLS AND BRACED PANELSMAY BE IN EXCESS OF THESE REQUIREMENTS. TWO INCH WASHERS ARE ONLY REQUIRED AT FULL HEIGHTFOUNDATION WALLS. BUILDING DESIGNER IS TO ACCOMMODATE LOAD PATH FOR ANY VERTICAL LOADTRANSFER OVER A SILL PLATE OVERHANG CONDITION.15.ANCHOR BOLTS 12" DIAMETER OR LARGER ARE NOT REQUIRED TO BE CORROSION PROTECTED INACCORDANCE WITH CODE SECTION R317.3.1 EXCEPTION 1.16.ALL PRE-MANUFACTURED FASTENERS AND CONNECTORS ARE TO BE INSTALLED IN ACCORDANCE WITHTHE MANUFACTURER'S REQUIREMENTS.17.FLOOR BLOCKING IS ONLY REQUIRED AT FULL HEIGHT FIRST FLOOR NON-BEARING FOUNDATION WALLS.18.CARE IS TO BE TAKEN DURING CONCRETE PLACEMENT TO MINIMIZE INADEQUATE HORIZONTAL ANDDIAGONAL COLD JOINTS, AND TO PREVENT THESE JOINTS ENTIRELY IN WALLS WITHOUT VERTICALREINFORCEMENT. ADEQUATELY VIBRATE CONCRETE AT POTENTIAL JOINT LOCATIONS AS REQUIRED,BASED ON PLACEMENT CONDITIONS TO ELIMINATE HONEYCOMBING AND TO ENSURE SUFFICIENT BONDINGIS ACHIEVED.19.TOP AND BOTTOM OF FOUNDATION WALLS ARE TO BE LATERALLY SUPPORTED PRIOR TO BACKFILLING.MEANS AND METHODS OF LATERAL SUPPORT ARE BY OTHERS.EQUIVALENT REBAR TABLEFOR BUNDLED HORIZONTAL BARS(2)#4 = (1)#6(3)#4 = (2)#5(3)#5 = (2)#6GRADE 60 #6 VERTICAL BAR SPACING FOR FULL HEIGHT WALLS w/ F'c = 3000 PSIALTERNATIVE TO CODE TABLE R404.1.2EQUIVALENT VERTICAL REBARSUBSTITUTION TABLEBACKFILL TYPECLEAR HEIGHT(SEE 5/F1)BACKFILL HEIGHT(SEE 5/F1)8'-0"9'-0"10'-0"7'-6"7'-0" OR LESS8'-6"8'-0"7'-0"6'-0" OR LESS9'-6"9'-0"8'-0"7'-0"6'-0" OR LESS8"10"12"8"10"12"8"10"12"NONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONE* = NONE IF F'c = 4,000 PSI*36"*36"*36"*36"*36"*36"36"36"36"36"36"36"36"36"24"24"24"24"SAND (30 PSF/FT)WALL THICKNESSSANDY CLAY (45 PSF/FT)WALL THICKNESSCLAY (60 PSF/FT)WALL THICKNESS#6 @ 24" = #5 @ 18" = #4 @ 12" (GRADE 60) = #4 @ 8" (GRADE 40)(1)#6 = (2)#4 (GRADE 60)#6 @ 36" = #5 @ 24" = #4 @ 18" (GRADE 60) = #4 @ 12" (GRADE 40)(2) #4 HORIZONTAL BARSBOTH TOP & BOTTOMEXTENDED AT LEAST 24"BEYOND EACH END OF STEPSTABLE BANKHIGH FOOTING MAY BEEXTENDED PROVIDEDBARS ARE PLACED ASSHOWNHORIZ. BARSTOP & BOTTOM6" MIN THICK CONCRETEFOUNDATION, SEE OTHERDETAILS FOR MORE INFOOPTIONAL CONTROL JOINTAT EACH END OF STEP72" MAX SPANEQ.EQ.24" MINDETAIL B3" MIN TYPCONCRETE STRIPFOOTING11BDETAIL A36" MINSTEP2 x STEPSTEP NOTE:DO NOT LOCATE CONCENTRATED LOADS IN EXCESS OF 2,000 PLF OR 10,000 POUNDS ABOVE STEPLOCATIONS SHOWNREAR FROST WALLLOOKOUTWALLFULL HEIGHTWALLGARAGE FROSTWALLELEVATIONSHOWN FORREPRESENTATIONPURPOSES ONLY-MAY NOT APPLYELEVATIONSTEP SPACING REQUIREMENTSATYP.6"MIN.WOOD FRAMING ABOVE BY OTHERS12"Ø x 10" LONG ANCHORBOLTS (7" MIN. EMBED)@ 72" O.C. MAX. OREQUIVALENT METALSTRAP ANCHORSSLOPE GRADE AWAYFROM FOUNDATIONOPTIONAL STEM WALLMINIMUM THICKNESS TOMATCH SILL PLATESILL PLATE TO MATCHFRAME WALL ABOVE16" MAX FOR 4" THICK STEM24" MAX. FOR 6" THICK STEMSLAB-ON-GRADE BY OTHERS(1) #4 x CONTINUOUSHORIZONTAL BAR ATTOP OF WALL6" MIN. C.I.P. CONCRETEFOUNDATION WALLUNREINFORCED CONCRETESTRIP FOOTING SEE 5/F1#4x2'-0" DOWELS @ 72" O.C. MAX(5" MIN. EMBED) DOWELS ARENOT REQUIRED IF BACKFILL ISPLACED EQUALLY ON BOTHSIDES IN LIFTS NOT TO EXCEED24"-ALTERNATE EACH SIDE6"MIN.6'-0" MAX WOOD FRAMINGABOVE BY OTHERS12"Ø x 10" LONG ANCHORBOLTS (7" MIN. EMBED)@ 72" O.C. MAX. OREQUIVALENT METALSTRAP ANCHORSSLOPE GRADE AWAY FROMFOUNDATION AT A GRADUAL 2%SLOPE PER GENERAL NOTE 6SILL PLATE TO MATCHFRAME WALL ABOVE#4 x CONTINUOUS HORIZONTALBARS @ 24" O.C. TYP.OPTIONAL 2" RIGID INSULATION ONINSIDE FACE AND UNDERSLAB-ON-GRADE FOR 24" MIN.UNREINFORCED CONCRETESTRIP FOOTING SEE 5/F1(DROP FOR FROST ASREQUIRED PER SITE DESIGN)#4x2'-0" DOWELS @ 48" O.C.MAX (5" MIN. EMBED)(1) #4 x CONTINUOUS HORIZONTALBAR AT TOP OF WALLOPTIONAL SLAB LEDGECONCRETE SLAB-ON-GRADE8" MIN. C.I.P. CONCRETEFOUNDATION WALL#4x4'-0" HOOKS @ 24" O.C. BENT ORDRILLED AND EPOXY GROUTED3'-0"1'-0 " NO HOOKS @ 3'-0" OR LESS GRANULAR MATERIAL (SAND)DETAIL ABOVE MAY ONLY BE UTILIZED FOR A LENGTH OF 15'-0"#5 VERTICAL BARS @ 24" O.C.CENTERED IN WALL TO AID INTHE REDUCTION OF CRACKINGAND BACKFILLING ISSUES PRIORTO TOP OF WALL PINNINGCONTRACTOR IS TO PROVIDETEMPORARY TOP OF WALLBRACING UNTIL GARAGESLAB-ON-GRADE IS IN PLACE(HOOKS INTO GARAGE SLABPROVIDE REQUIRED TOP OFWALL LATERAL SUPPORT) CLEAR HEIGHT BACKFILL HEIGHT112" CLEARUNREINFORCED CONCRETE STRIPFOOTING PER CODE OR BY BUILDINGDESIGNER, AS AN ALTERNATIVE GUIDEUSE TABLE SHOWN AT LEFT8" MIN. C.I.P. CONCRETEFOUNDATION WALL-SEEREBAR TABLE 6/F1 FORVERTICAL REBARANCHOR BOLTS SEE WALLANCHOR INFO ON 2/F2FLOOR TO SILLCONNECTION SEE 1/F2WOOD FLOORSYSTEM BY OTHERSSLOPE GRADE AWAYFROM FOUNDATION2x6 MIN SILL PLATECLEAR HEIGHT OF 8'-0" OR LESS(2)#4xCONT. HORIZONTAL BARSCLEAR HEIGHT OF 8'-0" OR MORE(3)#4xCONT. HORIZONTAL BARSGENERAL STRIP FOOTING SIZE GUIDEONE-STORYSTRUCTURE16" WIDE x 8" THICK20" WIDE x 8" THICKTWO-STORYSTRUCTURE20" WIDE x 8" THICK26" WIDE x 8" THICK2000 PSFSOIL1500 PSFNOTE: TABLE ABOVE IS A GENERAL FOOTING SIZE GUIDE THAT SHOULD BE VERIFIED BY HOMEDESIGNER AND IS BASED ON 25'-0" FLOOR SPANS & 50'-0" ROOF SPANSCONCRETESLAB-ON-GRADEPLACED TIGHT TOFOUNDATION WALL6"MIN.3'-0" MAX GRADE HEIGHT ABOVE TOP OF SLAB#4 x 2'-0" DOWELS (5" MIN.EMBED) CENTERED IN WALL @48" O.C. (SAND SOIL)OR 36" O.C. (SANDY-CLAY SOIL)OR 24" O.C. (CLAY SOIL)DOWELS MUST BE WET SET ORDRILLED AND EPOXY GROUTED6" MIN. THICK C.I.P.CONCRETEFOUNDATION WALLSLOPE GRADE AWAYFROM FOUNDATION12"Ø x 10" LONG ANCHORBOLTS (7" MIN. EMBED)@ 72" O.C. MAX. OREQUIVALENT METALSTRAP ANCHORS(1) #4 x CONTHORIZONTAL BARAT TOP OF WALLFRAMING & SILLPLATE BY OTHERSSLAB-ON-GRADEBY OTHERS#4x2'-0" DOWELS @ 72" O.C.MAX (5" MIN. EMBED)UNREINFORCED CONCRETESTRIP FOOTING SEE 5/F1(18" MIN WIDTH FOR CLAYBACKFILL OR 16" MIN WIDTH IF2'-6" MAX UNBALANCED BACKFILL)SCOPE OF DRAWINGS:THESE CAST-IN-PLACE CONCRETE FOUNDATION WALL GUIDELINE DRAWINGS ARE PREPARED ANDCERTIFIED BY THE HANSON GROUP IN COMPLIANCE WITH THE MINNESOTA RESIDENTIAL CODE. THESEDRAWINGS CONTAIN STRUCTURAL INFORMATION FOR USE IN THE CONSTRUCTION OF STANDARD C.I.P.CONCRETE FOUNDATIONS FOR TYPICAL RESIDENTIAL CONDITIONS. THIS INFORMATION IS RELEVANTTO THE CONCRETE CONTRACTOR, THE GENERAL CONTRACTOR, AND THE FRAMING CONTRACTOR.THESE DRAWINGS EXPIRE ON DECEMBER 31, 2020.D R Horton 20860 Kenbridge Court #100Lakeville, MN 55044 COPYRIGHT HANSON GROUP LLC 2020©DescriptionDateRevisionJanuary 1, 2020Project Number:Date:0.001F22Sheets: of2Print Name:Signed: License Number:Nick Hanson1-1-2046665Date:I hereby certify that this plan, specification or reportwas prepared by me or under my direct supervisionand that I am a duly Licensed Professional Engineerunder the laws of the State of Minnesota.CONNECTION INFOTOP OF WALL CONNECTION TOFLOOR SYSTEM1F2BRICK LEDGE INFO5F2WALL SECTIONAT WINDOW WELL LOCATIONS6F2STOOP INFO7F2WALL ANCHOR INFOANCHOR BOLT AND ALTERNATIVESPACING2F2BLOCKING DETAILFLOOR JOIST CONDITION3F2BLOCKING DETAILFLOOR TRUSS CONDITION4F2SITE ADDRESS:City:State:Zip:MN3407 Kilmer Lane NorthSuite 4Plymouth, MN 55441Tel 612-708-3572www.hansongroupmn.comVENEER ORSLAB-ON-GRADEBY OTHERSFOUNDATIONWALL SEE 5/F1WOOD FLOORSYSTEM BYOTHERSFRAMING BY OTHERS16" HIGH MAX x6" THICK MINSTEM6"MINWOOD FLOORSYSTEM BYOTHERSFRAMING BY OTHERS6" MIN THICK STEM#4 DOWELS @ 36" O.C.EMBEDDED 24" INTOLOWER WALLFOUNDATIONWALL SEE5/F1VENEER ORSLAB-ON-GRADEBY OTHERS12"VENEER ORSLAB-ON-GRADEBY OTHERSFOUNDATION WALLSEE 2/F1 OR 3/F1FRAMING BYOTHERS16" HIGH MAXx 4" THICK MINSTEMTHICKNESS TOMATCH SILLPLATE6"3'-0" MAX VENEER ORSLAB-ON-GRADEBY OTHERSFOUNDATION WALLSEE 4/F1SLAB-ON-GRADEFRAMING BYOTHERS6" MIN THICKSTEMDETAIL @ HIGH GRADESIM @ NON-BEARINGDETAIL @ LOOKOUTSIM @ FROST WALLDETAIL @ FROST WALLSw/ LOW GRADEDETAIL @ LOW GRADESIM @ NON-BEARING112"CLEARMINMAX#4 DOWELS @36" O.C.EMBEDDED 24"INTO LOWERWALL (CENTERIN STEMWALL)6"12"Ø ANCHOR BOLTS w/ NUT & 18" THICKx 2"Ø OR SQUARE WASHER SEE 2/F2FOR SPACING (7" EMBED MIN)-METAL STRAP ANCHORS TO BEINSTALLED AT MANUFACTUREREQUIVALENT SPACINGFLOOR SYSTEM, TYPE,SIZE, AND SPACING TO BEDETERMINED BY OTHERSRIM BOARD OR BRACINGMATERIAL BY OTHERS2x6 SILL PLATE MINIMUMFLOOR TO SILL CONNECTION ATEACH MEMBER SEE TABLE BELOWWASHER TO BE COUNTERSUNKFLUSH w/ TOP OF SILL PLATESEE FULL HEIGHT WALL SECTIONON 5/F1 FOR FOUNDATION WALLREQUIREMENTSSLOPE GRADE AWAYFROM FOUNDATIONMINTRUSS/JOIST CONNECTION FOR FULL HEIGHT WALLS****BACKFILL TYPECLEAR HEIGHT(SEE 5/F1)FLOOR MEMBERSPACING8'-0"9'-0"10'-0"16"19.2"A(4) 0.131"Ø x 3" TOP NAILS AT EACH MEMBERSAND(30 PSF/FT)SANDY CLAY(45 PSF/FT)CLAY(60 PSF/FT)24"16"19.2"24"16"19.2"24"AAAAAAABAABBBBBCCCDDDDDDDCCONNECTION A(4) 0.148"Ø x 3" TOP NAILS AT EACH MEMBERCONNECTION B(2) 0.131"Ø x 3" TOP NAILS & MECHANICAL CLIPS : SIMPSON A35/USP MPA1 OR USP LJC ATEACH MEMBERCONNECTION CCONNECTION D(2) 0.131"Ø x 3" TOP NAILS & MECHANICAL CLIPS : SIMPSON FWANZ* OR USP LJQ**OR (2) SIMPSON A35s***/(2) USP MPA1s*** AT EACH MEMBER12"Ø ANCHOR BOLT AND NON-BEARING WALL BLOCKING SPACING FOR FULL HEIGHT WALLS*ALTERNATIVE TO CODE TABLE R404.1.(1)BACKFILL TYPECLEAR HEIGHT(SEE 5/F1)BACKFILL HEIGHT(SEE 5/F1)8'-0"9'-0"10'-0"7'-6"7'-0"8'-6"8'-0"7'-0" OR LESS9'-6"9'-0"8'-0"7'-0" OR LESS72"* 12"Ø EPOXIED THREADED ROD w/ 6" EMBED MAY BE USED AT SPACING SHOWNSAND(30 PSF/FT)SANDY CLAY(45 PSF/FT)CLAY(60 PSF/FT)6'-0" OR LESS72"72"72"72"72"72"72"72"72"72"72"72"48"60"72"48"60"72"36"48"72"36"36"72"72"72"48"24"24"ALTERNATIVE ANCHOR SPACING FOR FULL HEIGHT WALLS**ALTERNATIVE TO CODE TABLE R404.1.(1)BACKFILL TYPECLEAR HEIGHT(SEE 5/F1)BACKFILL HEIGHT(SEE 5/F1)8'-0"9'-0"10'-0"7'-6"7'-0"8'-6"8'-0"7'-0" OR LESS9'-6"9'-0"8'-0"7'-0" OR LESS48"** APPLIES TO MAB 15/FA1, MAB23/FA2, MAS/FA3, 12"Ø EXPANSION BOLT w/ 6" EMBED,12"Ø SELF-CUTTING ANCHOR BOLT w/ 4" EMBED, OR SIMPSON FWAZ ANCHORSAND(30 PSF/FT)SANDY CLAY(45 PSF/FT)CLAY(60 PSF/FT)6'-0" OR LESS60"72"30"36"72"18"24"42"72"72"24"18"20"24"18"24"24"30"42"16"12"14"16"12"16"36"36"N/AN/A10'-0" MAX TO T.O.S. 1'-8" MAX FLASHING & WOODPROTECTION BYOTHERSFLOOR FRAMING ORBLOCKINGFLOORCONNECTIONSEE 1/F2 &2/F2C.I.P. CONCRETEWALL SEEADJACENTPLANS FORTHICKNESS &MAXIMUM WALLLENGTHSSEE FULLHEIGHT WALLSECTION 5/F1FORREINFORCINGSTOOPSLAB BYOTHERS13'-6" @ 10" WALL3'-0" MIN.10'-6" @ 8" WALL13'-6" @ 10" WALL3'-0" MIN.10'-6" @ 8" WALL13'-6" @ 10" WALL10'-6" @ 8" WALL13'-6" @ 10" WALL3'-0" MIN.10'-6" @ 8" WALL13'-6" @ 10" WALL10'-6" @ 8" WALL3'-0" FULL HEIGHT BASEMENTMIN FULL HEIGHT FULL HEIGHT EXAMPLE CORNEROR STRAIGHT WALLOPTIONS -TYPSTOOP AREA8" MIN C.I.P. CONCRETEWALL SEE FULL HEIGHTWALL SECTION 5/F1NOTES:1.ADD RETURN WALLS OR BUTTRESSES IN STOOP AREA AS SHOWN IF OVERALL STOOP CENTER TO CENTERWIDTH EXCEEDS DIMENSIONS SHOWN.2.STOOP WALLS REQUIRE MINIMUM 16" WIDE x 8" DEEP CONCRETE STRIP FOOTING.EXAMPLE '1'EXAMPLE '2'EXAMPLE '3'SLOPE GRADEAWAY FROMFOUNDATIONSLOPE GRADEAWAY FROMFOUNDATIONSLOPE GRADEAWAY FROMFOUNDATIONSLOPE GRADEAWAY FROMFOUNDATIONNOTE: INCREASE STRIP FOOTING WIDTH AT ALL WALLS SUPPORTING MORE THAN 6'-0" OF VENEER.WIDTH TO INCREASE BY THICKNESS OF VENEER MULTIPLIED BY NUMBER OF STORIES.TYP * FWANZ TO BE USED WITH A MIN. 118" OSB RIM AND LOCATED w/IN 5" OF EACH MEMBER. WITH FLOOR TRUSSES,FWANZ MUST BE IN CONTACT WITH A TRUSS OR A MINIMUM 2x4 CONTINUOUS BOTTOM BRACE MUST BE IN PLACE.** LJQ IS TO BE APPROPRIATELY SIZED BASED ON MEMBER WIDTH.*** MEMBER MUST BE A MINIMUM OF 3" WIDE FOR PLACEMENT OF (2) SIMPSON A35s/(2) USP MPA1s.****CONNECTIONS ARE CLASSIFIED A TO D, WITH D BEING THE STRONGEST. IT IS ACCEPTABLE TO USE ASTRONGER CLASS CONNECTION THAN NOTED IN THE TABLE ABOVE.2x8 SILL PLATE TO BE USED w/MAXIMUM OF 112" OVERHANG(MAINTAIN 234" EDGE DISTANCETO BOTH CONCRETE AND INSIDEOF SILL PLATE) - VERTICAL LOADTRANSFER BY SUPPLIERBACKFILL BELOWEXTERIOR STOOP SLABSWITH COMPACTEDGRANULAR MATERIALTO FROST DEPTH(4'-0" MINIMUM)NAIL SHEATHING TO BLOCKING/JOISTS0.131 Ø x 3" LONG NAILS @ 6" O.C.STRUCTURAL RIM BOARD BY OTHERSTYPE D CONNECTOR@ BLOCKING SEE 1/F22 x 6 MINSILL PLATEFOUNDATION WALL SEE OTHER SHEETSFOR ANCHORS & WALL INFOSLOPE GRADE AWAY FROMFOUNDATIONIF REQUIRED, PROVIDE 2 x 4 MINSPACERS UNTIL SPACES IN WHICH FULLHEIGHT BLOCKING CAN BE INSTALLED,TOE NAIL TO FLOOR MEMBERS EACH ENDw/ (12) 0.131"Øx3" LONG NAILSFRAMINGBY OTHERSOPTIONAL OPEN SPACE AS SHOWNOR SHIFT FULL HEIGHT BLOCKINGPROVIDE BLOCKINGAS REQUIRED TO ACHIEVENAILING SHOWN. (MIN 2SPACES) BLOCKING HEIGHTTO MATCH JOIST DEPTH &BE OF LUMBER, I-JOIST, OROTHER MANUFACTUREDMATERIAL ATTACHBLOCKING TO JOISTS w/ TOENAILS EACH ENDJOISTS BY OTHERSSEE 2/F2 FOR SPACING OFBLOCKING SYSTEM SHOWNNOTES:1.MAIN LEVEL FLOOR SHEATHING TO BE 34" PLYWOOD/OSB PLACED IN STAGGERED PATTERN NAILED w/ 0.131"Ø x3" LONG NAILS @ 6" O.C. AT PANELS EDGES & @ 12" O.C. @ PANEL INTERIOR SUPPORTS OF EQUIVALENT.2.NAILS IN BLOCKING ARE TO BE PLACED SUCH THAT THE WOOD DOES NOT SPLIT.3.BLOCKING MEMBERS SHOWN MAY BE REPLACED WITH PRE-MANUFACTURED TRUSS STYLE OR FULL DEPTHMEMBER BLOCKING SUCH AS I-JOIST OR LVL DESIGNED FOR 1,500 POUND LATERAL COMPRESSIVE LOAD.NAILING SHOWN IS TO BE USED AT MINIMUM.4.BLOCKING DOES NOT HAVE TO BE PLACED IN ADJACENT BAYS. IF REQUIRED USE ADDITIONAL 2x4 SPACERS ASSHOWN IN FIRST SPACE.5.HOLES MAY BE INSTALLED IN BLOCKING IF REQUIRED UP TO 4" IN DIAMETER, MAINTAIN 3" EDGE DISTANCE.NAIL SHEATHING TO BLOCKING/TRUSSESw/ (12) 0.131"Øx3" LONG NAILSDUCT/MECHANICAL (AS REQUIRED)BY OTHERSFRAMINGBY OTHERS0.131 Ø x 3" LONGNAILS @ 6" O.C.RIM TRUSSBY OTHERSTOP NAIL RIM TO SILLw/ MIN OF (12)0.131 Ø x3" LONG NAILS EACHSIDE OF BLOCKING ORTYPE D CONNECTOR @BLOCKING SEE 1/F22 x 6 MINSILL PLATEFOUNDATION WALL SEEOTHER SHEETS FORANCHORS & WALL INFOSLOPE GRADE AWAYFROM FOUNDATIONIF REQUIRED, PROVIDE 2 x 4 MIN SPACERSTOP & BOTTOM AT MECHANICAL UNTILSPACES IN WHICH BLOCKING CAN BEINSTALLED, TOE NAIL TO FLOOR MEMBERSw/ (2) 0.131 Ø x 3" LONG NAILS3/4" PLYWOOD/OSB ONE SIDEOF BLOCKING w/ (6) 0.131 Ø x 3" LONG NAILS TOP & BOTTOMOR 1/2" PLYWOOD/OSB EACHSIDE OF BLOCKING EACH w/(4) 0.131 Ø x 3" LONG NAILS TOP & BOTTOMPROVIDE 2 x 4 MIN BLOCKINGTOP & BOTTOM OF TRUSSESAS REQUIRED TO ACHIEVENAILING SHOWN.INSTALL w/ (2) 0.131 Ø x 3"LONG TOE NAILSTRUSSES BY OTHERSNOTES:1.MAIN LEVEL FLOOR SHEATHING TO BE 34" PLYWOOD/OSB PLACED IN STAGGERED PATTERN NAILED w/ 0.131"Ø x 3"LONG NAILS @ 6" O.C. AT PANELS EDGES & @ 12" O.C. @ PANEL INTERIOR SUPPORTS OF EQUIVALENT.2.NAILS IN BLOCKING ARE TO BE PLACED SUCH THAT THE WOOD DOES NOT SPLIT.3.BLOCKING MEMBERS SHOWN MAY BE REPLACED WITH PRE-MANUFACTURED TRUSS STYLE OR FULL DEPTH MEMBERBLOCKING SUCH AS I-JOIST OR LVL DESIGNED FOR 1,500 POUND LATERAL COMPRESSIVE LOAD. NAILING SHOWN IS TOBE USED AT MINIMUM.4.BLOCKING DOES NOT HAVE TO BE PLACED IN ADJACENT BAYS. IF REQUIRED USE ADDITIONAL 2x4 SPACERS ASSHOWN IN FIRST SPACE.5.HOLES MAY BE INSTALLED IN BLOCKING IF REQUIRED UP TO 4" IN DIAMETER, MAINTAIN 3" EDGE DISTANCE.SEE 2/F2 FOR SPACING OFBLOCKING SYSTEM SHOWN10'-0" MAX 3'-8" MAX 2'-6" MIN OPENING 1'-6" MIN 3'-0" EACH WAY MIN112" TYP SLOPE GRADE AWAYFROM FOUNDATION#4 HORIZONTAL BARS @12" O.C. CENTERED INWALLS LAP AROUNDCORNERS AND HOOKINTO FOUNDATION WALL@ EACH SIDE (REFER TO5/F1 FOR HORZ. BARREQUIREMENTS w/ 8"C.I.P. WALLS)6" MIN C.I.P.CONCRETE WALL#4 VERTICAL BARS @EACH OUTSIDECORNER OF WELL(1)#4 x2'-0" DOWEL @EACH OUTSIDECORNER OF WELL (5"MIN EMBED)12" WIDE x 8" THICK MINSTRIP FOOTING(1) #4 HORIZONTALBAR AT TOP OF WALL(2) #4 HORIZONTAL BARSTOP & BOTTOM OFLINTEL EXTEND 24" MINPAST OPENING EACHEND (WOOD OR STEELOPTION BY OTHERS)WALL BEYONDPLACE (2) #4 VERTICALBARS FULL HEIGHT ANDONE ANCHOR w/IN 12" OFOPENING EACH END8" MIN C.I.P.CONCRETE WALLSLAB-ON-GRADEUNREINFORCED CONCRETESTRIP FOOTING SEE FULLHEIGHT WALL SECTION 5/F1LOOKOUTWALLSEE 3/F1GRANULARMATERIAL(SAND)SLOPEWINDOW WELLLADDER/ESCAPEMEANS BYOTHERS5'-0" EACH WAY MAXFLOOR SYSTEM BY OTHERS(DO NOT PLACE GIRDERS ORBEAMS OVER CONCRETE LINTELDESIGNED FOR 1500 PLF)IF CONCRETEOPTIONAL RIGID INSULATION w/IN WINDOW WELL ATTHE DISCRETION OF THE BUILDER FOR ADDITIONALFROST PROTECTION AS REQUIRED PER SITE DESIGN6"MIN.A SECTION AD R Horton 20860 Kenbridge Court #100Lakeville, MN 55044 ProductsPlotID Net Qty ProductLength PliesB1 4 1-3/4" x 7-1/4" VERSA-LAM® 2.0 3100 SP 4' 0" 2B2 2 1-3/4" x 9-1/2" VERSA-LAM® 2.0 3100 SP 10' 0" 2UNEXCAVATEDOPTIONAL EGRESSWINDOW HEADER(3) 1-3/4"X7-1/4"X6'VERSA LAM LVLSTAIRWAYFLOOR TRUSSESBY OTHERSPORCH FLOORBY OTHERSB1B2B147' 0"31' 0" 10' 0"19' 6"17' 6"29' 0"26' 0" 22' 0" 2' 0" 19' 0" 5' 0" 18' 0"ProductsPlotID Net Qty ProductLength PliesB1 4 1-3/4" x 9-1/2" VERSA-LAM® 2.0 3100 SP 6' 0" 2B2 1 Beam by others 6' 0" 1B1B2B147' 0"ProductsPlotID Net Qty ProductLength PliesB1 2 1-3/4" x 7-1/4" VERSA-LAM® 2.0 3100 SP 4' 0" 2B2 2 1-3/4" x 9-1/2" VERSA-LAM® 2.0 3100 SP 8' 0" 2B3 1 Beam by others 8' 0" 1B1B2B347' 0"Sheet: 1 of 3DWG: Basement BeamsFile: Plan #5490-C3-GLBy: Anthony EstevezDate: 10-30-15Scale: 1/4" = 1' - 0"BC FRAMERD.R. HORTONBoise Building Material DistributionLakeville, MN (952) 469-5900SALES PRESENTATION DRAWINGNo structural or dimensional check has been made of this designdrawings of the building, therefore purchaser is to check andapprove all dimsensions, quantities, loads, and details carefully.This drawing has not been check by Boise Engineering.NOTE:ALL MEASUREMENTSTO BE VERIFIEDIN THE FIELD.12-1-18AERevisions:BY:"BEAM BY OTHERS" TO BE ADOUBLE 2X10 SPF #2SUPPLIED BY OTHERS,UNLESS NOTED OTHERWISE.NOTE:ALL HEADERS REQUIRE NOLESS THAN 3" OF BEARINGAT EACH END. UNLESSNOTED OTHERWISE.PLAN #5490-C3-GLD.R. HORTONBASEMENT BEAMSDESIGN = L/360BASE MODELBASEMENT BEAMSWALKOUT OPTIONLOOKOUT OPTIONDETAIL N/A ProductsPlotID Net Qty ProductLength PliesJ1 6 14" BCI® 4500s-1.8 32' 0" 1J2 12 14" BCI® 4500s-1.8 26' 0" 1J3 5 14" BCI® 4500s-1.8 20' 0" 1J4 6 14" BCI® 4500s-1.8 18' 0" 1J5 4 14" BCI® 4500s-1.8 14' 0" 1J6 1 14" BCI® 4500s-1.8 6' 0" 1B1 2 1-3/4" x 7-1/4" VERSA-LAM® 2.0 3100 SP 18' 0" 2B2 2 1-3/4" x 7-1/4" VERSA-LAM® 2.0 3100 SP 8' 0" 2B3 2 1-3/4" x 7-1/4" VERSA-LAM® 2.0 3100 SP 6' 0" 2B4 2 1-3/4" x 7-1/4" VERSA-LAM® 2.0 3100 SP 4' 0" 2B5 2 1-3/4" x 9-1/2" VERSA-LAM® 2.0 3100 SP 10' 0" 2B6 2 1-3/4" x 9-1/2" VERSA-LAM® 2.0 3100 SP 8' 0" 2B7 2 1-3/4" x 11-7/8" VERSA-LAM® 2.0 3100 SP 20' 0" 2B8 2 1-3/4" x 11-7/8" VERSA-LAM® 2.0 3100 SP 10' 0" 2B9 2 1-3/4" x 14" VERSA-LAM® 2.0 3100 SP 10' 0" 2B10 1 1-3/4" x 14" VERSA-LAM® 2.0 3100 SP 8' 0" 1B11 2 Beam by others 6' 0" 1B12 1 Beam by others 4' 0" 1Ca1 14 1-1/8" x 14" BC RIM BOARD OSB 12' 0" 1Pt1 2 Post by others 8' 0" 1Connector SummaryPlotID Qty Manuf ProductH1 1 Simpson HU11H2 10 Simpson IUS1.81/14STAIRWAYPORCH ROOFBY OTHERSROOF TRUSSESBY OTHERSSTART FRAMING HEREJOISTS @ 19.2" OCSINGLETRIMMERSOPTIONAL 6 FTWIDE WINDOW2 PLY 9-1/2" LVLPt1Pt1B4B8B6B11B11B9B2B3B1B12B10B7B5Ca1Ca1Ca1Ca1Ca1Ca1Ca1Ca1J6J1J5J4J3J2H2H2H110' 0"26' 0" 17' 6"22' 0" 5' 0" 47' 0"31' 0" 2' 0" 29' 0"19' 0" 19' 6"18' 0"9' 6"Sheet: 2 of 3DWG: Upper Floor FramingFile: Plan #5490-C3-GLBy: Anthony EstevezDate: 10-30-15Scale: 1/4" = 1' - 0"BC FRAMERD.R. HORTONBoise Building Material DistributionLakeville, MN (952) 469-5900SALES PRESENTATION DRAWINGNo structural or dimensional check has been made of this designdrawings of the building, therefore purchaser is to check andapprove all dimsensions, quantities, loads, and details carefully.This drawing has not been check by Boise Engineering.NOTE:ALL MEASUREMENTSTO BE VERIFIEDIN THE FIELD.12-7-19AERevisions:BY:"BEAM BY OTHERS" TO BE ADOUBLE 2X10 SPF #2SUPPLIED BY OTHERS,UNLESS NOTED OTHERWISE.NOTE:ALL HEADERS REQUIRE NOLESS THAN 3" OF BEARINGAT EACH END. UNLESSNOTED OTHERWISE.PLAN #5490-C3-GLD.R. HORTONUPPER FLOOR FRAMINGDESIGN = L/480BASE MODELUPPER FLOOR FRAMINGDETAIL N/ADETAIL N/A ProductsPlotID Net Qty Product Length PliesB1 1 Girder Truss by others 18' 0" 1B2 1 Beam by others 8' 0" 1B3 8 Beam by others 4' 0" 1STAIRWAYROOF TRUSSESBY OTHERSSINGLETRIMMERSSINGLETRIMMERSSINGLETRIMMERSSINGLETRIMMERSSINGLETRIMMERSSINGLETRIMMERSSINGLETRIMMERSSINGLETRIMMERSB3B3B1B3B2B3B3B3B3B310' 0"26' 0" 17' 6"22' 0" 5' 0" 47' 0"31' 0" 2' 0" 29' 0"19' 0" 19' 6"18' 0"Sheet: 3 of 3DWG: Upper Floor HeadersFile: Plan #5490-C3-GLBy: Anthony EstevezDate: 10-30-15Scale: 1/4" = 1' - 0"BC FRAMERD.R. HORTONBoise Building Material DistributionLakeville, MN (952) 469-5900SALES PRESENTATION DRAWINGNo structural or dimensional check has been made of this designdrawings of the building, therefore purchaser is to check andapprove all dimsensions, quantities, loads, and details carefully.This drawing has not been check by Boise Engineering.NOTE:ALL MEASUREMENTSTO BE VERIFIEDIN THE FIELD.11-10-15AERevisions:BY:"BEAM BY OTHERS" TO BE ADOUBLE 2X10 SPF #2SUPPLIED BY OTHERS,UNLESS NOTED OTHERWISE.NOTE:ALL HEADERS REQUIRE NOLESS THAN 3" OF BEARINGAT EACH END. UNLESSNOTED OTHERWISE.PLAN #5490-C3-GLD.R. HORTONUPPER FLOOR HEADERSDESIGN = L/360BASE MODELUPPER FLOOR HEADERSDETAIL N/A %12;4+)*6*#0510)4172..%‹&GUETKRVKQP&CVG4GXKUKQP1EVQDGT2TQLGEV0WODGT&CVG55JGGVUQH&4*QTVQP-GPDTKFIG%QWTV.CMGXKNNG/0Ä%Ä)./QFGN/KPPGUQVC%QPUVTWEVKQP-KNOGT.CPG05WKVG2N[OQWVJ/06GNÄÄYYYJCPUQPITQWROPEQO2.#055*190.+)*6+0$#%-)4170&#4'(14.1%#6+104'('4'0%'10.;2.#0016'5#0&'.'/'0655*190.+)*6/#;0160'%'55#4+.;57221466*'*#0510)4172ž5&'5+)0Z$.1%-+0)$'69''064755'50#+.'&616122.#6'5Y  F0#+.5'#%*0#+.'#%*,1+56616122.#6'Y  F61'0#+.50#+.$1661/2.#6'61$.1%-+0)Y  F0#+.5'8'4;+06'4+14$'#4+0)9#..+06'4+14010Ä$'#4+0)9#..2418+&'(7..&'26*$.1%-+0)$'69''0,1+5650#+.'&616122.#6'5Y  F0#+.5'#%*0#+.$1661/2.#6'61$.1%-+0)Y  F0#+.5'8'4;2418+&'64755&+4'%6.;+0.+0'Y$4#%'&9#..2#0'.(#56'0'&612.#6'5YF61'0#+.5"1%2418+&',1+56&+4'%6.;+0.+0'Y$4#%'&9#..2#0'.(#56'0'&612.#6'5YF61'0#+.5"1%6*+55*''654'24'5'065#%1/2.'6'&'5+)01(6*'³/#+09+0&(14%'4'5+56+0)5;56'/´(146*''06+4'4'5+&'06+#.5647%674'6*'.1%#6+10#0&.'0)6*1('#%*$4#%'&9#..2#0'.#0&'0)+0''4'&9+0&4'5+56+0)'.'/'066*#6+54'37+4'&(146*'*#0510)4172ž5&'5+)0+55*190106*'5647%674#.&4#9+0)59#..501652'%+(+%#..;.#$'.'&106*'2.#05/#;$'56#0&#4&(4#/+0)5'%6+1055*190&'2+%6%100'%6+1051($4#%'&9#..2#0'.561411(64755'5#$18'61,1+56564755'5$.1%-+0)#$18'#0&61,1+56564755'5$.1%-+0)$'.196*'5'2#0'.5#4'0160'%'55#4+.;4'37+4'&61#.+)0$76/#;&'2'0&+0)102.#0.#;1760#+.'#%*64755616122.#6'Y  F61'0#+.50#+.$1661/2.#6'61$.1%-+0)Y  F0#+.5'8'4;2418+&'(7..&'26*$.1%-+0)$'69''064755'50#+.'&616122.#6'5Y  F0#+.5'#%*0#+.$1661/2.#6'61$.1%-+0)Y  F0#+.5'8'4;2418+&'64755&+4'%6.;+0.+0'Y$4#%'&9#..2#0'.(#56'0'&612.#6'5YF61'0#+.5"1%411(64755'5$4#%'&9#..2#0'.(.#6Z"1% /+0  2'4$4#%'&9#..2#0'. 5+/2510#(4#/+0)#0).''#%*'0&  ŒZ0#+.52418+&'9+&6*9'$56+(('0'4(14#66#%*/'061((4#/+0)#0).'$4#%'&9#..2#0'.  ŒZ0#+.55+/2510#(4#/+0)#0).''#%*'0&(.114,1+5652418+&'9+&6*9'$56+(('0'4(14#66#%*/'061((4#/+0)#0).'$4#%'&9#..2#0'.  ŒZ0#+.55+/2510#(4#/+0)#0).''#%*'0&(.114,1+565$4#%'&9#..2#0'.  ŒZ0#+.55+/2510.62(4#/+0)2.#6''#%*'0&(.11464755'5(.#6Z"1% /+0  2'4$4#%'&9#..2#0'. (.#6Z"1% /+0  2'4$4#%'&9#..2#0'. (.#6Z"1% /+0  2'4$4#%'&9#..2#0'. $4#%'&9#..2#0'.  ŒZ0#+.55+/2510.62(4#/+0)2.#6''#%*'0&(.11464755'5(.#6Z"1% /+0  2'4$4#%'&9#..2#0'. $4#%'&9#..%100'%6+10$4#%'&9#..%100'%6+10$4#%'&9#..%100'%6+10 411(64755'5 (.114,1+565 (.11464755'5 &'6#+.55*190#$18'#4'#.6'40#6+8'%100'%6+10561$'75'&9*'0$4#%'&9#..2#0'.&1'5016#.+)09+6*(4#/+0)':6'4+14010Ä$'#4+0)9#..411(64755(#56'0'&612.#6'5YF61'0#+.5"1%0#+.4+/6122.#6'5YF61'0#+.5"1%0#+.$1661/2.#6'614+/,1+56$.1%-+0)Y  F0#+.5'8'4;0#+..#&&'464755616122.#6'5YF0#+.5"1%0#+.$1661/2.#6'61.#&&'464755Y  F0#+.5'8'4;411(64755'5(#56'0'&612.#6'5Y  F61'0#+.5 5+/2510*%.+2Z$.1%-+0)$'69''064755'50#+.'&616122.#6'5Y  F0#+.5'#%*0#+.'#%*,1+56616122.#6'5Y  F61'0#+.50#+.$1661/2.#6'614+/,1+56$.1%-+0)Y  F0#+.5'8'4;0#+.'#%*64755616122.#6'5Y  F61'0#+.50#+.$1661/2.#6'614+$$10$4#%'64755Y  F0#+.5'8'4;(4#/'Z$1:#4170&52#%'$'69''064755Y5#/'5*'#6*+0)#0&(#56'0+0)#59#..$'.19 144'2.#%'Y#&'37#6'&'26*Z/'/$'4 Z911&5%4'95"1%+056#..'&+0#&&+6+10610#+.5 /#+0722'4.'8'.411(64755$'#4+0)9#..510.; Z911&5%4'95"1%+056#..'&+0#&&+6+10610#+.5 /#+0722'4.'8'.411(64755$'#4+0)9#..510.; ':6'4+14$'#4+0)9#..4'24'5'065(+)74'4  +0&+%#6'5+06'4+14$4#%'&9#..2#0'.Y);257/5*'#6*+0)$16*(#%'59+6*'+6*'4(#56'0'4126+10.+56'&+0016'52#%'&#61%2418+&'+0%4'#5'&(#56'0+0)4'37+4'/'065#55*190$'.19+0&+%#6'5':6'4+14$4#%'&9#..2#0'.Y5*'#6*+0)10':6'4+14(#%'+0#%%14&#0%'Y016'2418+&'+0%4'#5'&(#56'0+0)4'37+4'/'065#55*190$'.19+0&+%#6'5'0)+0''4'&9+0&4'5+56+0)'.'/'06561$'%105647%6'&#55*190+06*'&'6#+.5*''65 /+0.'0)6* /+0.'0)6* +0&+%#6'5':6'4+14$4#%'&9#..2#0'.Y5*'#6*+0)10':6'4+14(#%'+0#%%14&#0%'Y016'2418+&'+0%4'#5'&(#56'0+0)4'37+4'/'065#55*190$'.19 /+0.'0)6* Y,1+565Y64755'5Y,1+565Y64755'5Y,1+565Y64755'5Y,1+565Y64755'52TKPV0COG5KIPGF.KEGPUG0WODGT&CVG+JGTGD[EGTVKH[VJCVVJKURNCPURGEKHKECVKQPQTTGRQTVYCURTGRCTGFD[OGQTWPFGTO[FKTGEVUWRGTXKUKQPCPFVJCV+COCFWN[.KEGPUGF2TQHGUUKQPCN'PIKPGGTWPFGTVJGNCYUQHVJG5VCVGQH/KPPGUQVC4[CP/CEMÄÄ5%12'&'5+)0#0&&'6#+.1(6*'/#+09+0&(14%'4'5+56+0)5;56'/(14#5+0).'Ä(#/+.;4'5+&'0%'%105647%6+10+561$'+0#%%14&#0%'9+6*6*+5&1%7/'0656#0&#4&+0&7564;24#%6+%'#0&6*'%1&'016'56*'5'&1%7/'065#22.;615647%674#.10.;4'('461%105647%6+10&1%7/'065(14/14'+0(14/#6+10#..':6'4+149#..5#4'61$'%105647%6'&+0#%%14&#0%'9+6*6*'(1..19+0)%4+6'4+#7019*+%*/''6514':%''&56*'4'37+4'/'0651(%1&'5'%6+104Ä5($#0&%5Ä5($#Z567&552#%'&"1%$/+09#..5*'#6*+0)(+$'4$1#4&5*'#6*+0)Y)#.8#0+<'&411(0#+.514F0#+.514)#7)'56#2.'5"1%#62#0'.'&)'5#0&1%#6+06'4/'&+#6'57221465016'&15$':6'4+149#..5#4'61$'%105647%6'&+0#%%14&#0%'9+6*6*'(1..19+0)%4+6'4+#7019*+%*/''6514':%''&56*'4'37+4'/'0651(%1&'5'%6+104Ä952#0&%5Ä952#Z567&552#%'&"1%$':6'4+145*'#6*+0)/+05647%674#.2#0'.5*'#6*+0)YF0#+.5"1%#62#0'.'&)'5#0&1%#6+06'4/'&+#6'5722146514)#7)'56#2.'5"52#%+0)%#/+0+/7/Ä+0%*911&5647%674#.2#0'.%140'44'67405*#..$'2418+&'&#6$16*'0&51(#%106+07175.;Ä5*'#6*'&$4#%'&9#...+0'+0#%%14&#0%'9+6*(+)74'4+0.+'71(6*'%140'44'6740#6+'Ä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Ä%'06'4ž%#.+(140+#%140'45ž1464#&+6+10#.%140'45#4'#%%'26#$.'2418+&'&(7..*'+)*65#90$.1%-+0)567&+5&+4'%6.;$'*+0&(.#62146+101(567&5(#56'0'&61)'6*'4+0#5+/+.#4(#5*+10/#6'4+#.59#..567&5 ž14.'55 52(567&)4#&'14$'66'49#..567&5 18'4ž 52(01)4#&'14$'66'4&+/'05+10#..7/$'452(01)4#&'14$'66'464'#6'&.7/$'45;201)4#&'14$'66'4.5.9+&6*Ä'14$'66'4.8.9+&6*Ä'14$'66'4.1#&5411(5019.1#&Ä25(411(&'#&.1#&25((.114.+8'.1#&25((.114&'#&.1#&25(9+0&.1#&/2*':2$%1&'/+00'516#4'5+&'06+#.%1&'*#4&9#4'#.6'40#6'6#$.'5+/2510241&7%6752241&7%6#/2#/2#*46*66*66.56#564#25#/'.62/2(/56%564#25#/'56*&4,56#&4,6+6'0*&9'&)'$1.6*#4&9#4'+05#/'419/#;$'75'&+06'4%*#0)'#$.;+06*+5&1%7/'06 Ä(6 Ä(6 Ä(6 Ä(6 Ä(6 Ä(6 Ä(6 Ä(6 Ä(6 Ä(6 Ä(6 Ä(6 Ä(6 Ä(6 $4#%'& 9#...+0' $4#%'& 9#...+0' $4#%'& 9#...+0'$4#%'&9#...+0'$4#%'&9#...+0' Ä(6 Ä(6 Ä(6 Ä(6 Ä(6 Ä(6 $4#%'&9#...+0'$4#%'&9#...+0'2#46+#..19'4.'8'.*175'2.#05*190(14.1%#6+104'('4'0%'10.;54'('4'0%'2.#06*'4'37+4'/'0655*190&+4'%6.;#$18'10.;#22.;619#.-176(170&#6+1056*'4'37+4'/'0655*190&+4'%6.;#$18'10.;#22.;61.11-176(170&#6+105/#+0.'8'.*175'2.#05*190(14.1%#6+104'('4'0%'10.;54'('4'0%'2.#015$%105647%62146#.(4#/'#55*190+05žÄ01661':%''&žÄ(#56'06122.#6'61*'#&'4Y  4195F5+0-'40#+.5"1%  Z$'#4+0)567&   Z(7..*'+)*6567&'#%*'0&1(*'#&'4.1%#6'2#0'.,1+069+6*+0žÄ(41/%'06'41(9#..*'+)*6#54'3ž& Z51.+&$.1%-+0)4'37+4'&#65*'#6*+0),1+06  Z$'#4+0)567&5/+0 8'4+(;Y5722.+'4 5+/251056*&'/$'&&'&*1.&190#0%*14#6.1%#6+1055*190 4'('4615(14#.6'40#6+8'126+105 (170&#6+109#..$'.19.'0)6*1(%106+07175*'#&'4Œ#0%*14$1.6 /+0'/$'& YZZ2.#6'9#5*'40#+.5*'#6*+0)61*'#&'4YF0#+.5"1%'#9#;6;25/#..*#6%*#4'#+0&+%#6'5146*+%-'42.;911&1415$5*'#6*+0)#22.+'&61':6'4+145+&'1(567&5 0#+.5*'#6*+0)#4170&2'4+/'6'4Y  4195F0#+.5"1%56#))'4'& 612.#6'5$.1%-+0)"1% 5+/2510/56%564#210+05+&'(#%'1(9#.. 2418+&'52#%'461(.75*176*'#&'4619#..567&6*+%-0'55 (#56'0-+0)567&61*'#&'4Y  4195F5+0-'40#+.5"1%5(4#/+0)&'6#+.)#4#)'(41062146#.(4#/'016'+0(1#22.+'55;//'64+%#..;#%4155&'6#+.%106+07175.5..8.*'#&'46157221468'46+%#..1#&5$;5722.+'4 /+09+&6* /+0&'26*4'3ž& 2418+&'Z+0(+..9#..#$18'*'#&'4#54'3ž&.#4)'*#6%*#4'#+0&+%#6'5146*+%-'42.;911&1415$5*'#6*+0)#22.+'&61':6'4+145+&'1(567&5Y56#0&#4&0#+.+0)2418+&'(#56'0+0)1(#$18'(4#/+0)'37#.616*#6&'6#+.'&(14$4#%'&9#..2#0'.52156Ä+056#..'&*1.&190126+105(4#/+0)&'6#+.%10%4'6'(170&#6+10$'.195+/2510*66*1.&190#0%*14#6.1%#6+1055*1900#+.'&61&17$.'567&5YŒZ.10)5+/25106+6'0*&5%4'9Ä+0#0%*14+061%10%4'6'žÄžÄ Ä(6 Ä(6 Ä(6 Ä(6 Ä(6 Ä(6 Ä(6 Ä(6 Ä(6 Ä(6 Ä(6 Ä(6 $4#%'& 9#...+0' $4#%'&9#...+0'$4#%'&9#...+0'$4#%'&9#...+0'9#.-Ä+05*19'4126+10 AHdr15' 2"2' 0" 4' 4"9' 6"19' 11 5/8"3' 0"By: Anthony EstevezDate: 11-2-15RevisionsFile: Plan #5490Scale: 1/4"=1'DWG: Tall WallSheet: 1 of 1Boise CascadeLakeville, MNGeneral Notes:Boise Cascade Versa Studs shall be installed in accordance with BoiseCascade Corporations Engineered Wood Installation Guide.It is theresponsibility of the framing contractor to adhere to all recommendations forinstallation stated within. Boise Cascade installation guides can be obtained bycontacting a Boise Engineered wood Products specialist at 1-800-281-5503 orvisiting our website at www.bc.com.Design Criteria:Wind Load 20 PSFL/180Blocking @8' o.c. verticallySALES PRESENTATION DRAWINGNo structural or dimensional check has been madeof this design drawing of the building, thereforepurchaser is to check and approve all dimsensions,quantities, loads, and details carefully. This drawinghas not been check by Boise Engineering.1: 3-5-192:3:NOTE:CONTRACTOR IS TO VERIFY ALL DIMENSIONS ANDROUGH OPENING SIZES PRIOR TO ANYCONSTRUCTION OF WALLS. ROUGH OPENINGSIZES ARE ESTIMATES. VERIFY WITH WINDOWMANUFACTURER.NOTE:TALL WALL IS DESIGNED FOR VERTICAL LOADSAND HORIZONTAL WIND LOADS ONLY. LATERALWALL LINE BRACING OF THE BUILDING IS TO BEACCOUNTED FOR BY BUILDING DESIGNER.NOTE:STUDS, COLUMNS, AND HEADERS CALLED OUTREQUIRE LVL MATERIAL. PLATES, CRIPPLES,TRIMMERS, AND BLOCKING LABELED BY OTHERSDO NOT REQUIRE LVL MATERIAL AND ARE NOTINCLUDED IN QUOTE.COLUMN A:(2) 1-1/2"X5-1/2" VERSA STUDSCONNECT COLUMNS TO PLATES WITH 6 - 16D NAILSOR TWO A23 ANGLE CLIPS AT BOTH TOP ANDBOTTOM.COLUMN B:N/AHEADERS:Hdr1 = (2) 2x10 by othersSINGLE TRIMMER REQUIRED FOR SUPPORT ATEACH END OF HEADER AS SHOWN.2x6 WallCOLUMN C:N/ASTUDS:1-1/2"X5-1/2" VERSA STUDS @ 16" OCPLAN #5490 GARAGE LEFTALL ELEVATIONSD. R. HORTONTALL WALL @ STAIRWAYDouble top plateby othersSingle bottom plateby othersOnly upper 6 ft of wallis exposed to wind load. Date Certificate Posted x Passive (No Fan ) Active (With fan and monometer or other system monitoring device) Location (or future Location) of Fan: X R-10/R15 X X R-20 X R-20 X R-21 X R-49 X R-49 X R-30 X R-32 X X Not applicable, all ducts located in conditioned space R-8 MECHANICAL SYSTEMS X Not required per mech. code Passive Powered Interlocked with exhaust device. Describe: Input in BTUS:60000 Capacity in Gallons:Other, describe: AFUE or HSPF%92% Cfm's " round duct OR " metal duct Not required per mech. code X Passive Low: Other, describe: X Low: Cfm's Capacity continuous ventilation rate in cfms:5 " round duct OR Total ventilation (intermittent + continuous) rate in cfms: " metal duct Location of duct or system: Select Type furnace room Heat Recover Ventilator (HRV) Capacity in cfms: Energy Recover Ventilator (ERV) Capacity in cfms: Describe any additional or combined heating or cooling systems if installed: (e.g. two furnaces or air source heat pump with gas back-up furnace Combustion Air Select a Type Balanced Ventilation Capcity in CFMS: High: High: Mechanical Ventilation System 85 50%=88 100%=176 NAT GAS R-410A Cooling System Rating or Size SEER or EER 50 Output in Tons:2.5 Efficiency RESIDENTIAL LOAD CALC 13 Locations of Fans, describe: HEAT LOSS 50,144 HEAT GAIN 22,211 COOLING LOAD 28,257Mineral FiberboardRigid, Extruded PolystyreneRigid, Isocynurate Appliances Model R-value0.30 PROG5042NRH67PV BA13NA030 Rheem Make-up Air Select a Type Building Envelope air Tightness:Duct system air tightness: Ceiling, flat Manufacturer 170 Interior Bryant Domestic Water Heater Heating System NAT GAS Bryant 912SB48060S17 Average U-Factor (excludes skylights and one door ) U: 0.31 Heating or Cooling Ducts Outside Conditioned Spaces Bonus room over garage Describe other insulated areas Fuel Type Solar Heat Gain Coefficient (SHGC): Windows & Doors Location of duct or system: Ceiling, vaulted Bay Windows or cantilevered areas Rim Joist (1st Floor+) Wall Per R401.3 Building Certificate. A building certificate shall be posted on or in the electrical distribution panel. New Construction Energy Code Compliance Certificate Name of Residential Contractor DRHorton MN License Number BC605657 Mailing Address of the Dwelling or Dwelling Unit 8630 188th St W Chokecherry Hill Plan ID 5490 North Foundation Wall Perimeter of Slab on Grade Rim Joist (Foundation) Community RADON SYSTEM Interior THERMAL ENVELOPE Either/OR, See Plans For Location Other Please Describe Here Below Entire Slab Total R-Value of all Types of InsulationType: Check All That Apply Non or Not ApplicableFiberglass, BlownFiberglass, Batts Insulation Location Foam, Closed CellFoam Open Cell 5490 North HVAC Load Calculations for DR Horton Lakeville, MN Prepared By: Michael Hoium Sabre Plumbing & Heating 15535 Medina Road Plymouth, MN 55447 763-473-2267 Thursday, November 16, 2017 Rhvac is an ACCA approved Manual J and Manual D computer program. Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D. Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Sabre Plumbing & Heating 5490 North Plymouth, MN 55447 Page 2 Project Report General Project Information Project Title:5490 North Designed By:Michael Hoium Project Date:Thursday, November 16, 2017 Client Name:DR Horton Client City:Lakeville, MN Company Name:Sabre Plumbing & Heating Company Representative:Michael Hoium Company Address:15535 Medina Road Company City:Plymouth, MN 55447 Company Phone:763-473-2267 Company Fax:763-473-8565 Design Data Reference City:Minneapolis, Minnesota Building Orientation:Front door faces North Daily Temperature Range:Medium Latitude:44 Degrees Elevation:834 ft. Altitude Factor:0.970 Outdoor Outdoor Outdoor Indoor Indoor Grains Dry Bulb Wet Bulb Rel.Hum Rel.Hum Dry Bulb Difference Winter:-15 -12.38 n/a 30%72 29.40 Summer:88 73 50%50%75 35 Check Figures Total Building Supply CFM:996 CFM Per Square ft.:0.258 Square ft. of Room Area:3,865 Square ft. Per Ton:1,641 Volume (ft³):32,230 Building Loads Total Heating Required Including Ventilation Air:50,144 Btuh 50.144 MBH Total Sensible Gain:22,211 Btuh 79 % Total Latent Gain:6,045 Btuh 21 % Total Cooling Required Including Ventilation Air:28,257 Btuh 2.35 Tons (Based On Sensible + Latent) Notes Rhvac is an ACCA approved Manual J and Manual D computer program. Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at your design conditions. Thursday, November 16, 2017, 2:40 PM Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Sabre Plumbing & Heating 5490 North Plymouth, MN 55447 Page 3 Load Preview Report Scope Net Ton ft.² /Ton Area Sen Gain Lat Gain Net Gain Sen Loss Sys Htg CFM Sys Clg CFM Sys Act CFM Duct Size Building 2.35 1,641 3,865 22,211 6,045 28,257 50,144 587 996 996 System 1 2.35 1,641 3,865 22,211 6,045 28,257 50,144 587 996 996 12x15 Ventilation 943 3,944 4,888 6,314 Humidification 6,152 Zone 1 3,865 21,268 2,101 23,369 37,678 587 996 996 12x15 1-Basement 1,312 3,466 0 3,466 11,962 186 162 162 2--5 2-Main Floor 1,312 11,131 2,101 13,232 13,419 209 521 521 5--6 3-Second Floor 1,241 6,671 0 6,671 12,297 191 313 313 3--6 Thursday, November 16, 2017, 2:40 PM Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Sabre Plumbing & Heating 5490 North Plymouth, MN 55447 Page 4 Total Building Summary Loads Component Description Area Quan Sen Loss Lat Gain Sen Gain Total Gain DRH LowEE 3228: Glazing-DRH Windows, u-value 0.32, SHGC 0.28 222 6,186 0 3,512 3,512 DRH LowEE 2929: Glazing-DRH Windows, u-value 0.29, SHGC 0.29 40 1,009 0 679 679 DRH LowEE 2924: Glazing-DRH Windows, u-value 0.29, SHGC 0.24 12 303 0 176 176 DRH LowEE 3029: Glazing-DRH Windows, u-value 0.3, SHGC 0.29 48 1,253 0 821 821 DRH LowEE 3123: Glazing-DRH Door w/ Sidelite, u- value 0.31, SHGC 0.23 6.7 180 0 56 56 DRH LowEE 3021: Glazing-DRH Windows, u-value 0.3, SHGC 0.21 12 314 0 94 94 11J: Door-Metal - Fiberglass Core 37.8 1,972 0 544 544 DRH- R15 8ft: Wall-Basement, Custom, DRH- 8" poured concrete wall, R-15 board insulation to footing, no interior finish, 8' floor depth 304 1,560 0 154 154 DRH- R15 4ft: Wall-Basement, Custom, DRH- 8" poured concrete wall, R-15 board insulation to footing, no interior finish, 4' floor depth 96 492 0 48 48 12F-0sw: Wall-Frame, R-21 insulation in 2 x 6 stud cavity, no board insulation, siding finish, wood studs 2777.5 15,707 0 2,400 2,400 DRH- R10 8ft: Wall-Basement, Custom, DRH- 8" poured concrete wall, R-10 board insulation to footing, no interior finish, 8' floor depth 376 1,930 0 191 191 RJ 20 Spray Foam: Wall-Frame, Custom, Rim Joist R-20 Closed Cell Spray Foam 394 1,714 0 482 482 R49 16B-49: Roof/Ceiling-Under Attic with Insulation on Attic Floor (also use for Knee Walls and Partition Ceilings), Custom, R-49 Blown Insulation, No Radiant Barrier, Vented Attic, Asphalt Shingles 1240.8 2,483 0 1,370 1,370 21A-28: Floor-Basement, Concrete slab, any thickness, 2 or more feet below grade, no insulation below floor, any floor cover, shortest side of floor slab is 28' wide 1312 2,511 0 0 0 20P-30: Floor-Over open crawl space or garage, Passive, R-30 blanket insulation, any cover 21 64 0 6 6 Subtotals for structure:37,678 0 10,533 10,533 People:6 1,200 1,380 2,580 Equipment:901 4,116 5,017 Lighting:1250 4,263 4,263 Ductwork:0 0 0 0 Infiltration: Winter CFM: 0, Summer CFM: 0 0 0 0 0 Ventilation: Winter CFM: 170, Summer CFM: 170 6,314 3,944 943 4,888 Humidification (Winter) 16.78 gal/day :6,152 0 0 0 AED Excursion:0 0 976 976 Total Building Load Totals:50,144 6,045 22,211 28,257 Check Figures Total Building Supply CFM:996 CFM Per Square ft.:0.258 Square ft. of Room Area:3,865 Square ft. Per Ton:1,641 Volume (ft³):32,230 Building Loads Total Heating Required Including Ventilation Air:50,144 Btuh 50.144 MBH Total Sensible Gain:22,211 Btuh 79 % Total Latent Gain:6,045 Btuh 21 % Total Cooling Required Including Ventilation Air:28,257 Btuh 2.35 Tons (Based On Sensible + Latent) Notes Thursday, November 16, 2017, 2:40 PM Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Sabre Plumbing & Heating 5490 North Plymouth, MN 55447 Page 5 Total Building Summary Loads (cont'd) Notes Rhvac is an ACCA approved Manual J and Manual D computer program. Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at your design conditions. Thursday, November 16, 2017, 2:40 PM 04/09/2020 X KP