Loading...
HomeMy WebLinkAboutSURVEYS 11x17 Zoning = RS-4 �0 ��-' `' The curb box,drain tile cleanout,and catch / �� ��� � ���, z x basln(if applicabie)musi be inspected and I FY - 20' House, 25� Caafag@� x x 34. 'rJ� accepted before As-Built escrow monies will � SY- 7' Interior, 20' Corner � � x� 7 0 � „ be released. All structures must be flush RY - 30� � 589�,52 55 W,��� � � with the sod. This will be scheduled with the , �, a� w �g��,2� '� landscape inspection. SY Buffer- 30 ' ��i� (s�6.9)�� -' �� RY Buffer - 50' � � � � �----�`-�—o ��--� *Draintile connection required. � � x L'�/ � \'� � ENGINEERING REVIEWED ��o'iD'-' � `D'� � � � �� D8�@:10/29/2020 co�ioWs� �� L// ^(\� ���.� � � A X y /�� `V J�\�p� / \ � � �a � Q �� '��� cfl EROSION CONTROL �L�� �'� oo,��<Qe // X \ 5 �`J p MUSTBEINSTALLED i ,�� '' �o��et�e ,,,�� \� � BEFORE EXCAVATION /� � ,+�/ � e° /'a N�+ /�L� x A^ / x � � /� ♦-\ �l' / \ '� \ � ��/ L��� 04 ,� a \��� " *Maintain 6" between bottom of siding and sod. '° �` � ��' \ " g1g,48 "No structures in easements. � X �� �� " /�� '°'� � Bench `°-�x / � ' x (g18•4� � � � _ ,o —— � J > � ° �X � � ,- � , x �691 ,\\ // �,j � � �'m �i `�/ � �` � x \ ✓ " � � � .�. `°�� ,�� ,,� t���'' i / ` m�a �5'� ,�j �/ � x \\ X fP \ �� � \ � � ,� � �S � 1� � .� _ �' \\ 39 � o•,o � 1� F N° � �'� `��� � ✓ w P � i0.� 1 co rn� � X \ . �,,,X 61 ° �� i w � o- a O � `�\ � 1918 : p��. \,o`'�r 6� x �, •' � ,� \�� �+ gd �r' �v �.`� •N 1 � i� '� i�� . ; p5 ,: CQ' NW X 0� 1 .� � x / Q(�OJye �', , Op �r � � �� �• 1 ��� � �� �-�� �; F 0,,�a � � � N � A �, , i � '� ��// �\ �W' f 'a X � � � \ ��,p 1� V1 918.39 .J � c� I,oN �, -^, `°a �� �� � Benchmark \ � �o �, � � ,� ' `°�� � ''�� � " i �� ,��91 x� � � �� NW x��' ` , � X �,x c'O ✓ �_`926.5)- �/'� 1 � � �a ; , Q� lY� �� \9 'a+ \ ��`�a��� �� � ``�iD� '�g 6 � '9%1r ✓ �`� � � x \ `�'' 1� 'I '�O r 50 >-'(1"5 �� � 1 to�ie �, �'��,, P��G 2� °� ��o � � Benc�hmark �6, � ; G� ; Y''a1�'1� � � J � x � �� .�� � � �a; ;o //� �� � 9l \ � .� ❑ `°a \ ''� , ' o � �o l9 � ■ �°'X VaCant \ � ,�20�x� �� � � �/ � � �'°� 2o`'a� 9ti6� oy a \a / �X o `°� (g24i ��o g� � QOoPe,�dy v,� mp� � rX / � a�, m Ec1•� \'\ � � m 's ,�� '';X`9*y6• �/ \ �� ��63°�� � 'o � �p �� 5� X '°�> 923.93 �� `°?> o � � Benchmark ' � ,��, ,� — � > ` �61 : `°a D�1�`po� / , / X ///��� 1"] / / �o ���'/ v i / M_y v v , � 9,��ti° ��' $ � �N �a� ,��6,� , � P .� 'I°�o o ��,0 �o �`' / / � Denotes iron pipe S Denotes service Lowest floor elevation Lot area = 11089 SF 3�� per grading plan : 918,4 House area = 1959 SF ❑O Denotes television box Porch area = 118 SF ■ Denotes electric box House elevations (Pro osed� / As—built Sidewalk area = 30 SF ❑� Denotes teiephone box Lowest Floor Elevation ;�g�g.�� � � Driveway area = 719 SF X 000.00 Denotes existing elevation Patio area = 18 SF ) proposed eievotion Top Of Foundation Elev. ;(927,�� � ( 000.00 Denotes Total Impervious Area = 2844 SF � Denotes droinage flow direction Gorage Slab Elev. � Door ;(g2g,7� � Impervious Coverage = 25.69' � Denotes spike ■�����■ Denotes proposed retaining wall Construction Notes: designed and built by others. 1. Install rock construction entrance. 2. Install silt fence as needed for erosion control. 0� 10� 20' 3. 5idewalks shall drain away from house o minimum of 1.0%. 4. Contractor must verify driveway design. 5. Contractor must verify service elevation prior to construction. 6. Add or remove foundation ledge as required. 7. Retaining walls are conditional; Wall installed if the grade exceeds 3:1. SCale: 1�� = 20� Wall will not be installed if the grade is 3:1 or less. General Notes: Benchmark: 1. Groding plan by KJ Walk last dated 5-11-20 was used to determine proposed We hereby certify to Brandl Anderson Homes Inc that this survey, Top Nut Hydrant elevations shown herein. lan or re ort was Lots 8-9 Block 2 2. This survey does not pur ort to show im rovements or encroachments, P P prepared by me or under my direct supervision, P P and that I am a duly licensed Land Surveyor under the laws of the Elevation = 927.20 except as shown, as surveyed by me or under my direct supervision. State of Minnesota, dated 10/02/20. 3. Proposed building dimensions shown are for horizontol location of structures on the lot only. Contoct builder prior to construction for approved construction plans. Signed: io eer En ineering, P.A. Revisions: 4. No s ecific soils investi ation has been iJ�o-c�-zoscakehouse P g performed on this lot by the surveyor. The suitability of soils to support the specific house proposed is not the responsibility of the surveyor. BY� 5. This certificate does not purport to show easements other than those shown eter . Hawkinson, rofessional Land Surveyor on the recorded plat. Minnesota License No. 42299 email—phawkinsonC�pioneereng.com 6. Bearings shown are based on an assumed datum. PI��ER Lot 9� Block 2. ����'�P� PHEASANT RUN OF LAKEVILLE FIFTH ADDITION Certificate of Survey for: CIVR.ENCINEERS LANDPLAN\ERS LAVD9URVLVORS L.4\�SGPCARCfiITCCTS occording to the recorded plat thereof Brandl Anderson Homes Inc 2422 Enterprise Drive Ph.:(651)681-1914 Dakota County. Minnesota Mendota Heights,MN 55120 Fax:(651)681-9488 221 River Ridge Circle South,Suite 100 www.pioneereng.com Address: 17843 Elder Avenue, Lakeville, Minnesota Burnsville,MN 55337 House Model: Edgestone Elevation: N/A Phone:(952)898-0230 Project#:12p147008 Folder#:8516 Drawn by:CWM Buyer: Abiye Tola n PinnPar FnoinrPnna 185591 c Pioneer Engineering Revisions: 1.) 10-06-20 Stake house 2.) 05-28-21 Grading As-built Certificate of Survey for: 2422 Enterprise Drive Mendota Heights, MN 55120 Ph. : (651) 681-1914 www.pioneereng.comFax: (651) 681-9488 Project # :Folder #:Drawn by: CIVIL ENGINEERS LAND PLANNERS LAND SURVEYORS LANDSCAPE ARCHITECTS Brandl Anderson Homes Inc 221 River Ridge Circle South, Suite 100 Burnsville, MN 55337 Phone: (952) 898-0230 11x17