HomeMy WebLinkAbout19999 Hiawatha Ct Survey(1012.6)(1012.0)1515200TH STREET WESTHIAWATHA COURT25.3310.0022.3725.45C.O.C.O.OS 21.00HUB=1011.95OS 43.51HUB=1007.12OS 40.67HUB=1004.84OS 31.17HUB=1006.20221004.3R:1008.03R:999.06R:999.67R:1007.48SERV1004.0999.61008.01012.01010.91010.01008.11004.31004.41004.71009.01002.71000.01002.3 1006.1(1006.2)(1012.0)(1007.1)(1004.8)(1004.8)(1013.00)(1012.6)(1004.8)(1004.8)(1004.0)(999.6)(1008.0)PROPOSEDHOUSEDRAINAGE &UTILITY EASEMENT7.9%EX. SODEX. SODEXISTINGHOUSEGARAGEPORCHSIDEWALKFD IPFD IP FD IPFD IPFD IP1007.81013.61011.81011.91008
.
0
1008.11006.61006.4999.5998.6998.71003.71010.31010.4N80°02'07"E144.31N09°57'53"W83.29Δ=0°22'37"R=1040.006.84Δ=9°06'57"R=960.00152.74S00°18'46"W
84.56
24.50 11.17 17.33 10.00 3.00 14.67 3.00 17.00 33.66 11.67 4.00 9.67 10.00 18.33 2.00 10.08EX. FIRE PIT53.6147.6110101012.355 6.00 21.3424.019.7(1006.8)FBWO1004.71003.8
1003.11002.31003.21004.01000.5TNH1011.79LOOKOUT1007.6(1008.0)TW=1011.5BW=1008.0DENOTES EXISTING CATCH BASINDENOTES EXISTING HYDRANTDENOTES EXISTING SANITARY MANHOLEDENOTES EXISTING STORM MANHOLEDENOTES EXISTING COMMUNICATION BOXDENOTES EXISTING ELECTRIC BOXDENOTES EXISTING SERVICE OR CLEANOUTDENOTES IRON MONUMENT FOUNDDENOTES IRON MONUMENT SETDENOTES EXISTING POWER POLEDENOTES EXISTING LIGHT POLEDENOTES EXISTING CONSERVATION POSTOR WET LAND BUFFER POSTDENOTES EXISTING TREEPPLP8" TREE000.0DENOTES WOOD HUBDENOTES NAILDENOTES EXISTING RETAINING WALLDENOTES PROPOSED RETAINING WALLDENOTES EXISTING ELEVATIONDENOTES PROPOSED ELEVATIONDENOTES AS BUILT ELEVATION(000.0)000.0DENOTES EXISTING TREELINEDENOTES DIRECTION OF SURFACE DRAINAGEDENOTES EXISTING FENCELEGENDDENOTES EXISTING F.E.S.LOT AREA : 12,991 SQ. FT.TOTAL IMPERVIOUS AREA : 2,819 SQ. FT. (21.7%)HOUSE AREA : 1,889 SQ. FT.PORCH AREA : 167 SQ. FT.DRIVEWAY AREA : 719 SQ. FT.SIDEWALK AREA : 44 SQ. FT.Legal Description:= FINISHED GARAGE FLOOR ELEVATION= BASEMENT FLOOR ELEVATION= TOP OF FOUNDATION ELEVATION(1013.00)(1013.33)(1005.33)1. No specific soils investigation has been performed on thislot by the surveyor. The suitability of the soils to support thespecific house is not the responsibility of the surveyor.2.No title information was provided for this survey. Thissurvey does not purport to show all easements of record.3. See architectural plans for final building dimensions.AREAS:NOTES: 1. 8'- 4" POURED FOUNDATION. 2. LOWEST ALLOWED FLOOR ELEVATION = 1005.3CERTIFICATE OF SURVEYBENCHMARK: TNH AT LOT 1 BLOCK 1. ELEVATION = 1011.79REVISED 06-01-2020: ADD LOOKOUT WINDOWS AT END OF HOUSEAND PROPOSED RETAINING WALL AT END OF PORCH.PER BUILDER REVIEW.Zoning = RS-4FY - 20' House, 25' GarageSY - 7' Interior, 20' CornerRY - 30'SY Buffer - 30'RY Buffer - 50'EROSION CONTROLMUST BE INSTALLEDBEFORE EXCAVATIONThe curb box, drain tile cleanout, and catchbasin(if applicable) must be inspected andaccepted before As-Built escrow monies willbe released. All structures must be flushwith the sod. This will be scheduled with thelandscape inspection.*Draintile connection required.*Maintain 6" between bottom of siding and sod.*No structures in easements.ENGINEERING REVIEWEDDate:__________________06/19/2020corlowsky