HomeMy WebLinkAbout18936 Hinton Avenue SurveyJames R. Hill, Inc.
PHONE: 952.890.6044 www.jrhinc.com
PLANNERS / ENGINEERS / SURVEYORSDRAWN BYDATEREVISIONSCAD FILEPRO-ECT NO.SHEET 1 OF 12999 WEST C.R. 42, SUITE 100, BURNSVILLE, MN 55306 Denotes set spikeDenotes set iron monumentDenotes found iron monumentDenotes found scribed "x"Denotes set hubDenotes proposed drainageDenotes top of curbDenotes existing elevationDenotes proposed elevationCERTIFICATE OF SURVEY
FOR
SHP6/17/2020400548.dwg400548Lot 2, Block 3, CHOKECHERRY HILL
5TH ADDITION,
Dakota County, Minnesota 1.Bearings are based on the recorded plat.2.Building dimensions shown are for horizontal and vertical placement ofstructure only. See architectural plans for building and foundationdimensions.3.No specific soils investigation has been completed on this lot by JamesR. Hill, Inc. the suitability of soils to support the specific house proposedis not the responsibility of James R. Hill, Inc. or the surveyor.4.No specific title search for existence or non-existence of recorded orun-recorded easements has been conducted by the surveyor as a partof this survey. Only easements per the recorded plat are shown.5.Proposed grades shown were taken from the grading &/ordevelopment plan prepared by PIONEER engineering.6.Grading plan date/revision date: December 21, 20187.Plan No. 5450-B 'WHITNEY'NOTESProposedGarage Floor @ Front= 1082.2Garage Top of Foundation= 1082.6House Top of Foundation= 1082.6Lowest Floor= 1074.6Lot 2, Block 3, CHOKECHERRY HILL 5TH ADDITION, Dakota County, MinnesotaPROPERTY DESCRIPTION18936 Hinton Avenue, Lakeville, MinnesotaPROPERTY ADDRESSI hereby certify that this survey, plan or report was prepared by me or undermy direct supervision and that I am a duly Licensed Land Surveyor under thelaws of the State of Minnesota. That this survey does not purport to show allimprovements, easements or encroachments, to the property except asshown thereon.Signed this 17th day of June, 2020Marcus F. Hampton, MN L.S. No. 47481SURVEYOR'S CERTIFICATEFLOOR ELEVATIONSBENCHMARKLot= 11,312 sq. ft.House/Garage= 2,330 sq. ft.Porch= 115 sq. ft.Driveway= 878 sq. ft.Sidewalk= 25 sq. ft.Patio= 18 sq. ft.Total Impervious= 3,366 sq. ft. or 29.76% of lotHARD COVER CALCULATIONSTop nut of hydrant located at Lot 1, Block 3 = 1083.19Zoning = RS-3FY - 30'SY - 10' Interior, 20' CornerRY - 30'SY Buffer - 30'RY Buffer - 50'The curb box, drain tile cleanout, and catchbasin(if applicable) must be inspected andaccepted before As-Built escrow monies willbe released. All structures must be flushwith the sod. This will be scheduled with thelandscape inspection.EROSION CONTROLMUST BE INSTALLEDBEFORE EXCAVATIONENGINEERING REVIEWEDDate:__________________07/13/2020corlowsky*Maintain 6" between bottom of siding and sod.*No structures in easements.