Loading...
HomeMy WebLinkAbout18377 Grasshopper Drive-SurveyHOUSE ELEVATION DATA HOUSE TYPE = TWO STORY LOT TYPE = FLAT LOT BASEMENT WALL HEIGHT = 8.3 PROPOSED GARAGE FLOOR EL.= 1005.0 PROPOSED TOP OF BLOCK EL.= 1005.3 PROPOSED LOWEST FLOOR EL.= 997.3 GRADING QUANTITIES (CY) COMMON FILL -360 COMMON CUT 260 FOOTINGS/TRENCHES 57 HARD SURFACES 27 TOTAL FILL -360 TOTAL CUT 344 TOTAL (+/-) -16 HOUSE ELEVATION DATA HOUSE TYPE = TWO STORY LOT TYPE = FLAT LOT BASEMENT WALL HEIGHT = 8.3 PROPOSED GARAGE FLOOR EL.= 1005.0 PROPOSED TOP OF BLOCK EL.= 1005.3 PROPOSED LOWEST FLOOR EL.= 997.3 GRADING QUANTITIES (CY) COMMON FILL -360 COMMON CUT 260 FOOTINGS/TRENCHES 57 HARD SURFACES 27 TOTAL FILL -360 TOTAL CUT 344 TOTAL (+/-) -16 Planning DepartmentApprovedDate:__________________08/10/2020 mcroatt The curb box, drain tile cleanout, and catchbasin(if applicable) must be inspected andaccepted before As-Built escrow monies willbe released. All structures must be flushwith the sod. This will be scheduled with the landscape inspection. *Draintile connection required. ENGINEERING REVIEWED Date:__________________08/14/2020 corlowsky EROSION CONTROL MUST BE INSTALLEDBEFORE EXCAVATION *Maintain 6" between bottom of siding and sod. *No structures in easements.