HomeMy WebLinkAboutLA183426 17961 Eventide Way Permit PackRESIDENTIAL BUILDING PERMIT APPLICATION PAGE 2 OFFICE USE ONLY BUILDING PERMIT TYPE REQUIRED INSPECTIONS SINGLE FAMILY DWELLING BUILDING DUPLEX AS BUILT TOWNHOUSE UNITS BUILDING FINAL DETACHED TOWN HOUSE UNIT DECK FOOTING CONDO FIREPLACE ACESSORY BUILDING FOOTING REROOF FOUNDATION RESIDE FRAMING PORCH FRAMING GARAGES INSULATION RES ADDN/REPAIR/RMDL DECK PORCH GARAGES LATH LOWER LEVEL FINISH LOWER LEVEL FINAL ADDITION OTHER FOUNDATION ONLY PORCH FOOTING MISCELLANEOUS POURED WALL DEMO SEPTIC TANK REMOVAL MOVED SITE MECHANICAL CITY BUILDING VALUATION: $AIR TEST FINAL BUILDING PERMIT FEES ROUGH-IN $PERMIT FEE PLUMBING $PLAN CHECK FINAL $SURCHARGE ROUGH-IN $METRO SAC METER SIZE $CITY WATER HOOKUP UNIT PRESSURE REDUCING VALVE $CITY SEWER HOOKUP UNIT SEWER/WATER $LANDSCAPE ESCROW SEWER/WATER $TREE ESCROW FINAL $MISC ESCROW STREET DRAINTILE $PLUMBING BUILDING INFORMATION $MECHANICAL TYPE OF CONSTRUCTION $SEWER WATER ZONING $OTHER CODE EDITION $TOTAL FIRE SUPPRESSION SYSTEM OCCUPANCY GROUP APPROVED BY: BUILDING INSPECTOR: Date: PLUMBING/MECHANICAL INSPECTOR: Date: COMMENTS: 20195 Holyoke Avenue, Lakeville, MN 55044 952-985-4400  952-985-4499 fax www.lakevillemn.gov Sewer & Water Tie Card Address:________________________________________ Contractor:______________________________________ Permit Number:__________________________________ Final Date:________________ Street Drain-Tile:______ Size of Water Service: 1” Comments: AIRTEST SANITARY OVER 20’/2 FITTINGS THIS CARD MUST BE COMPLETED AND ON-SITE AT TIME OF SEWER & WATER INSPECTION 08/10/2020XKP Secure door closed until deck isconstructed with a separate permit.Concept Approval ONLYSubject to Field InspectionInspectorDate2015MN BldgCode08/25/2020shutchins See Detail 1/PF-1Minimum (2) 1-3/4" x 11-7/8" Header per detailFOR THIS WALL LINE, INSTALL INTERIOR GYPSUM WALLBOARD WITH BLOCKING AT ALL HORIZONTAL JOINTS AND WITH 4” OC FASTENING AT ALL ENDS AND EDGES. SEE FASTENING SCHEDULE ON PLAN PAGE GSN. 3WSPWSPWSPWSP33UFER Ground-Provide 20' Rebar in footing and stubup near electrical service panel. 22x30 ATTIC ACCESSBWP aboveContinuous bearingrequired for girderabove to foundation. Top plates must beremoved.3WSPWSPWSPWSPWSPFOR THIS WALL LINE, INSTALL INTERIOR GYPSUM WALLBOARD WITH BLOCKING AT ALL HORIZONTAL JOINTS AND WITH 4” OC FASTENING AT ALL ENDS AND EDGES. SEE FASTENING SCHEDULE ON PLAN PAGE GSN. 14WSPFOR INDICATED PORTION OF BWL USE DETAIL /SC-1 FOR THE TOPPLATE SPLICES. IF NO TOP PLATESARE TO BE USED, INSTALL SIMPSONCS20 STRAP AT ALL BEAM OR PLATEJOINTS WITH MINIMUM 9" OVERLAP ATEACH END OF STRAP.1 4.5WSP6GBGB676WSPWSP6WSPSee Detail 2/PF-1Minimum (2) 2x12 Header per detailPFHPFHMinimum 3" x 11-1/4" Header per detailSee Detail 3/PF-1Minimum 3" x 11-1/4" Header per detailSee Detail 4/PF-1PFHVerify loads with girdertruss specs, may requireremoval of top plates atbearing due to crushing.-Min. 15" clearance to anyobstruction from center ofW.C., 24" in front(typ). The vapor barrier must be sealed atthe top & bottom plates & where theadjacent wall is insulated. All seamsshall be overlapped at least 6 inchesand sealed with compatible sealingtape or equivalent. (TYP)-Min. 15" clearance to anyobstruction from center ofW.C., 24" in front(typ).Temper glass if lessthan 36" off floorVerify loads with girdertruss specs, may requireremoval of top plates atbearing due to crushing.33333322222222Braced WallPanels WSP BWL 1BWL 210'10'3'3'FOR THIS WALL LINE, INSTALL INTERIOR GYPSUM WALLBOARD WITH BLOCKING AT ALL HORIZONTAL JOINTS AND WITH 4” OC FASTENING AT ALL ENDS AND EDGES. SEE FASTENING SCHEDULE ON PLAN PAGE GSN. 3'3'SEE DETAIL 1/PF-1 BWL 4BWL 5BWL 3BWL 6BWL 710'56'2'-3"2'-3"2'-3"3'3'SEE DETAIL 2/PF-1FOR THIS WALL LINE, INSTALL INTERIOR GYPSUM WALLBOARD WITH BLOCKING AT ALL HORIZONTAL JOINTS AND WITH 4” OC FASTENING AT ALL ENDS AND EDGES. SEE FASTENING SCHEDULE ON PLAN PAGE GSN. 17'17'BWL 4.58'6'6'6'14'SEE DETAIL 3/PF-1SEE DETAIL 4/PF-16'6'7'FOR INDICATED PORTION OF BWL USE DETAIL /SC-1 FOR THE TOPPLATE SPLICES. IF NO TOP PLATESARE TO BE USED, INSTALL SIMPSONCS20 STRAP AT ALL BEAM OR PLATEJOINTS WITH MINIMUM 9" OVERLAP ATEACH END OF STRAP.1 4.5 42'28'BWL 8BWL 9BWL 10BWL 112'2'2'2'2'2'2'2'3'3'3'3'3'3' Voigt & Associates, Inc.C-1Structural Engineering Services 4635 Nicols Road, Suite 204Eagan, MN 55122MethodCS-WSPWind speed 90Exposure C GB BWL 1 2 3 4 4.5 5 6 7 8 9 10 11Spacing - ft 10 10 10 17 17 17 56 56 28 28 42 42Level 3 3 2 2 2 2 2 2 1 1 1 1Length req'd- ft 5 5 3.5 5.6 11.2 5.6 16 16 4.7 4.7 6.3 6.3per Table R602.10.3(1)Adjustments:Exposure 1.4 1.4 1.3 1.3 1.3 1.3 1.3 1.3 1.2 1.2 1.2 1.2Eave to ridge Height 1 1 1 1 1 1 1 1 1 1 1 1Wall Height 0.9 0.9 0.95 0.95 0.95 0.95 0.95 0.95 0.9 0.9 0.90.9# of BWL 1.3 1.3 1.3 1.3 1.3 1.3 1 1 1 1 1 14" Gyp WB w.block joints0.7 1 0.7 1 1 1 1 1 1 1 1 1Adjusted Length 5.7 8.2 3.9 9.0 18.0 9.0 19.8 19.8 5.1 5.1 6.86.8Community Cares17961 Eventide Way, Lakeville, MN Sheet Passive (No Fan) Active (With fan and monitoring device ) Location (or future location) of Fan: Other Please Describe Here Not applicable, all ducts located in conditioned space Not required per mech. code Passive Powered Interlocked with exhaust device. Describe: Input in BTUS: Capacity in Gallons: Other, describe: AFUE or HSPF% Cfm's " round duct OR " metal duct Not required per mech. code Passive Low: Other, describe: Low: Location of fan(s), describe: Cfm's " round duct OR " metal duct Per R401.3 Certificate. A building certificate shall be posted on or in the electrical distribution panel. New Construction Energy Code Compliance Certificate Name of Residential Contractor MN License Number City Mailing Address of the Dwelling or Dwelling Unit Rigid, Extruded PolystyreneHeat Recover Ventilator (HRV) Capacity in cfms: Energy Recover Ventilator (ERV) Capacity in cfms: Combustion Air Select a Type Location of duct or system: Rim Joist (2nd Floor+) Building envelope air tightness: Below Entire Slab Fuel Type Solar Heat Gain Coefficient (SHGC): Windows & Doors Ceiling, vaulted Bay Windows or cantilevered areas Floors over unconditioned area THERMAL ENVELOPE Foam Open Cell Wall Rigid, Isocynurate Perimeter of Slab on Grade RADON CONTROL SYSTEM Total R-Value of all Types of InsulationType: Check All That Apply Mineral FiberboardInsulation Location Foam, Closed Cell Describe other insulated areas Ceiling, flat Non or Not ApplicableFiberglass, BlownFiberglass, Batts Foundation Wall Output in Tons: Appliances Cooling System Location of duct or system: Heating or Cooling Ducts Outside Conditioned Spaces Make-up Air Select a Type Domestic Water Heater Model Heating System Rim Joist (1st Floor) Average U-Factor (excludes skylights and one door ) U: Duct system air tightness: Rating or Size Efficiency Heating Gain Cooling Load Select Type Describe any additional or combined heating or cooling systems if installed: (e.g. two furnaces or air source heat pump with gas back-up furnace): Residential Load Calculation SEER /EER Capacity continuous ventilation rate in cfms: Heating Loss Manufacturer Total ventilation (intermittent + continuous) rate in cfms: Balanced Ventilation capacity in cfms: High: High: MECHANICAL VENTILATION SYSTEM Date Cert. Posted R-value MECHANICAL SYSTEMS Builders Associaton of Minnesota version 101014 17961 Eventide Way, Lakeville HVAC Load Calculations for Heartland Homes Prepared By: Jake Ryan Silver Tree Plumbing & Heating 1335 Mendota Heights Rd Mendota Heights, Mn 55120 651-900-7053 Thursday, July 30, 2020 Rhvac is an ACCA approved Manual J, D and S computer program. Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D. Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Silver Tree Plumbing & Heating 17961 Eventide Way, Lakeville Eagan, MN 55121 Page 2 Project Report General Project Information Project Title:17961 Eventide Way, Lakeville Designed By:Jake Ryan Project Date:7/30/2020 Project Comment:Community Cares MN Client Name:Heartland Homes Company Name:Silver Tree Plumbing & Heating Company Representative:Jake Ryan Company Address:1335 Mendota Heights Rd Company City:Mendota Heights, Mn 55120 Company Phone:651-900-7053 Company E-Mail Address:jaker@silvertreepandh.com Design Data Reference City:Minneapolis, Minnesota Building Orientation:Front door faces East Daily Temperature Range:Medium Latitude:44 Degrees Elevation:834 ft. Altitude Factor:0.970 Outdoor Outdoor Outdoor Indoor Indoor Grains Dry Bulb Wet Bulb Rel.Hum Rel.Hum Dry Bulb Difference Winter:-15 -15.33 n/a 30%72 33.90 Summer:88 73 50%50%72 42 Check Figures Total Building Supply CFM:1,431 CFM Per Square ft.:0.423 Square ft. of Room Area:3,386 Square ft. Per Ton:1,063 Volume (ft³):28,183 Building Loads Total Heating Required Including Ventilation Air:52,122 Btuh 52.122 MBH Total Sensible Gain:31,437 Btuh 82 % Total Latent Gain:6,766 Btuh 18 % Total Cooling Required Including Ventilation Air:38,203 Btuh 3.18 Tons (Based On Sensible + Latent) Notes Rhvac is an ACCA approved Manual J, D and S computer program. Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at your design conditions. F:\ ...\17961 Eventide Way, Lakeville - Heat Calc.rh9 Thursday, July 30, 2020, 12:11 PM Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Silver Tree Plumbing & Heating 17961 Eventide Way, Lakeville Eagan, MN 55121 Page 3 Load Preview Report Scope Has AED Net Ton ft.² /Ton Area Sen Gain Lat Gain Net Gain Sen Loss Min Htg CFM Min Clg CFM Sys Htg CFM Sys Clg CFM Sys Act CFM Duct Size Building 3.18 1,063 3,386 31,437 6,766 38,203 52,122 625 1,431 625 1,431 1,431 System 1 Main Floor No 3.18 1,063 3,386 31,437 6,766 38,203 52,122 625 1,431 625 1,431 1,431 13x18 Ventilation 890 4,342 5,232 5,428 Supply Duct Latent 79 79 Return Duct 5 15 20 29 Humidification 6,158 Zone 1 3,386 30,541 2,331 32,872 40,506 625 1,431 625 1,431 1,431 13x18 1-Basement 1,098 5,188 0 5,188 11,569 178 243 178 243 243 2--7 2-Main Level 1,098 15,163 2,331 17,494 15,087 233 710 233 710 710 6--6 3-Upper Level 1,190 10,190 0 10,190 13,850 214 477 214 477 477 4--6 F:\ ...\17961 Eventide Way, Lakeville - Heat Calc.rh9 Thursday, July 30, 2020, 12:11 PM Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Silver Tree Plumbing & Heating 17961 Eventide Way, Lakeville Eagan, MN 55121 Page 4 Duct Size Preview Room or Duct Name Source Minimum Velocity Maximum Velocity Rough. Factor Design L/100 SP Loss Duct Velocity Duct Length Htg Flow Clg Flow Act. Flow Duct Size System 1 Supply Runouts Zone 1 1-Basement Built-In 450 750 0.01 0.1 454.7 178 243 243 2--7 2-Main Level Built-In 450 750 0.01 0.1 603 233 710 710 6--6 3-Upper Level Built-In 450 750 0.01 0.1 607.9 214 477 477 4--6 Other Ducts in System 1 Supply Main Trunk Built-In 650 900 0.003 0.1 880.5 625 1,431 1,431 13x18 SummarySummarySummarySummarySummarySummarySummarySummary System 1 Heating Flow:625 Cooling Flow:1431 F:\ ...\17961 Eventide Way, Lakeville - Heat Calc.rh9 Thursday, July 30, 2020, 12:11 PM Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Silver Tree Plumbing & Heating 17961 Eventide Way, Lakeville Eagan, MN 55121 Page 5 Total Building Summary Loads Component Description Area Quan Sen Loss Lat Gain Sen Gain Total Gain LOWEE BUILDER GRADE: Glazing-LOWEE BUILDER GRADE, ground reflectance = 0.23, indoor insect screen with 100% coverage, U-value 0.32, SHGC 0.32 475.1 13,237 0 14,368 14,368 11J: Door-Metal - Fiberglass Core, U-value 0.6 37.8 1,972 0 612 612 12F-0sw: Wall-Frame, R-21 insulation in 2 x 6 stud cavity, no board insulation, siding finish, wood studs, U-value 0.065 2681.1 15,162 0 2,841 2,841 15B0-10sf-4: Wall-Basement, , R-10 board insulation to floor, no interior finish, 4' floor depth, U-value 0.054 80 376 0 0 0 15B0-10sf-8: Wall-Basement, , R-10 board insulation to floor, no interior finish, 8' floor depth, U-value 0.05 640 2,784 0 0 0 RJ R-20 RIM JOIST: Wall-Frame, Custom, RJ R-20 RIM JOIST R-20 SPRAY FOAM, U-value 0.05 215.9 940 0 220 220 RJ R-20: Wall-Frame, Custom, RJ R-20 RIM JOIST R20 SPRAY FOAM, U-value 0.05 193.3 842 0 198 198 R49 Attic: Roof/Ceiling-Under Attic with Insulation on Attic Floor (also use for Knee Walls and Partition Ceilings), Custom, R49 Attic, U-value 0.02 1329.9 2,314 0 1,833 1,833 21A-32: Floor-Basement, Concrete slab, any thickness, 2 or more feet below grade, no insulation below floor, any floor cover, shortest side of floor slab is 32' wide, U-value 0.02 1097.9 1,910 0 0 0 20P-30: Floor-Over open crawl space or garage, Passive, R-30 blanket insulation, any cover, U-value 0.035 224 682 0 86 86 Subtotals for structure:40,219 0 20,158 20,158 People:6 1,200 1,380 2,580 Equipment:1,131 4,262 5,393 Lighting:650 2,217 2,217 Ductwork:317 94 74 167 Infiltration: Winter CFM: 0, Summer CFM: 0 0 0 0 0 Ventilation: Winter CFM: 158, Summer CFM: 158 5,428 4,342 890 5,232 Humidification (Winter) 16.79 gal/day :6,158 0 0 0 AED Excursion:0 0 2,456 2,456 Total Building Load Totals:52,122 6,766 31,437 38,203 Check Figures Total Building Supply CFM:1,431 CFM Per Square ft.:0.423 Square ft. of Room Area:3,386 Square ft. Per Ton:1,063 Volume (ft³):28,183 Building Loads Total Heating Required Including Ventilation Air:52,122 Btuh 52.122 MBH Total Sensible Gain:31,437 Btuh 82 % Total Latent Gain:6,766 Btuh 18 % Total Cooling Required Including Ventilation Air:38,203 Btuh 3.18 Tons (Based On Sensible + Latent) Notes Rhvac is an ACCA approved Manual J, D and S computer program. Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at your design conditions. F:\ ...\17961 Eventide Way, Lakeville - Heat Calc.rh9 Thursday, July 30, 2020, 12:11 PM Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Silver Tree Plumbing & Heating 17961 Eventide Way, Lakeville Eagan, MN 55121 Page 6 Building Rotation Report All rotation degree values in this report are clockwise with respect to the project's original orientation. Building orientation as entered (zero degrees rotation): Front door faces East Individual Rooms Rm. No. Room Name 0° Rot. CFM 45° Rot. CFM 90° Rot. CFM 135° Rot. CFM 180° Rot. CFM 225° Rot. CFM 270° Rot. CFM 315° Rot. CFM High Duct Size System 1: Zone 1: 1 Basement *243 183 113 179 223 207 161 223 2--7 2 Main Level *710 649 566 644 667 662 605 703 6--6 3 Upper Level *477 409 319 395 430 405 342 442 4--6 * Indicates highest CFM of all rotations. Whole Building Rotation Degrees Front door Faces Supply CFM Sensible Gain Latent Gain Net Tons 0°East *1,431 *31,437 *6,766 *3.18 45°Southeast 1,241 27,385 6,766 2.85 90°South 999 22,217 6,766 2.42 135°Southwest 1,218 26,884 6,766 2.80 180°West 1,321 29,087 6,766 2.99 225°Northwest 1,274 28,092 6,766 2.90 270°North 1,108 24,552 6,766 2.61 315°Northeast 1,367 30,078 6,766 3.07 * Indicates highest value of all rotations. 2.2 2.4 2.6 2.8 3.0 East Southeast South Southwest West Northwest North NortheastCooling TonsDirection Front door Faces Building Rotation Tonnage Building Net Tonnage F:\ ...\17961 Eventide Way, Lakeville - Heat Calc.rh9 Thursday, July 30, 2020, 12:11 PM Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Silver Tree Plumbing & Heating 17961 Eventide Way, Lakeville Eagan, MN 55121 Page 7 Building Rotation Report (cont'd) 26,000 27,000 28,000 29,000 30,000 31,000 32,000 33,000 34,000 35,000 36,000 37,000 38,000 39,000 40,000 41,000 42,000 43,000 8 am 9 am 10 am 11 am 12 pm 1 pm 2 pm 3 pm 4 pm 5 pm 6 pm 7 pmBuilding Net Gain, BtuhTime of Day Building Rotation Hourly Net Gain Front door faces East Front door faces Southeast Front door faces South Front door faces Southwest Front door faces West Front door faces Northwest Front door faces North Front door faces Northeast F:\ ...\17961 Eventide Way, Lakeville - Heat Calc.rh9 Thursday, July 30, 2020, 12:11 PM