Loading...
HomeMy WebLinkAboutLA180800 5710 Upper 179th St Permit PackRESIDENTIAL BUILDING PERMIT APPLICATION PAGE 2 OFFICE USE ONLY BUILDING PERMIT TYPE REQUIRED INSPECTIONS SINGLE FAMILY DWELLING BUILDING DUPLEX AS BUILT TOWNHOUSE UNITS BUILDING FINAL DETACHED TOWN HOUSE UNIT DECK FOOTING CONDO FIREPLACE ACESSORY BUILDING FOOTING REROOF FOUNDATION RESIDE FRAMING PORCH FRAMING GARAGES INSULATION RES ADDN/REPAIR/RMDL DECK PORCH GARAGES LATH LOWER LEVEL FINISH LOWER LEVEL FINAL ADDITION OTHER FOUNDATION ONLY PORCH FOOTING MISCELLANEOUS POURED WALL DEMO SEPTIC TANK REMOVAL MOVED SITE MECHANICAL CITY BUILDING VALUATION: $AIR TEST FINAL BUILDING PERMIT FEES ROUGH-IN $PERMIT FEE PLUMBING $PLAN CHECK FINAL $SURCHARGE ROUGH-IN $METRO SAC METER SIZE $CITY WATER HOOKUP UNIT PRESSURE REDUCING VALVE $CITY SEWER HOOKUP UNIT SEWER/WATER $LANDSCAPE ESCROW SEWER/WATER $TREE ESCROW FINAL $MISC ESCROW STREET DRAINTILE $PLUMBING BUILDING INFORMATION $MECHANICAL TYPE OF CONSTRUCTION $SEWER WATER ZONING $OTHER CODE EDITION $TOTAL FIRE SUPPRESSION SYSTEM OCCUPANCY GROUP APPROVED BY: BUILDING INSPECTOR: Date: PLUMBING/MECHANICAL INSPECTOR: Date: COMMENTS: 20195 Holyoke Avenue, Lakeville, MN 55044 952-985-4400  952-985-4499 fax www.lakevillemn.gov Sewer & Water Tie Card Address:________________________________________ Contractor:______________________________________ Permit Number:__________________________________ Final Date:________________ Street Drain-Tile:______ Size of Water Service: 1” Comments: AIRTEST SANITARY OVER 20’/2 FITTINGS THIS CARD MUST BE COMPLETED AND ON-SITE AT TIME OF SEWER & WATER INSPECTION MAIN FLOOR1' -8 1/4"UPPER PLATE20' -5 1/4"T.O. FOUNDATION0' -0"MAIN PLATE10' -9 3/8"MAIN PLATE10' -9 3/8"UPPER FLOOR12' -4 1/8"MAIN FLOOR PLATE HEIGHT9' - 1 1/8"UPPER FLOOR PLATE HEIGHT8' - 1 1/8"GARAGE PLATE HEIGHT10' - 9 3/8"128ALUMINUM SOFFIT& FASCIA TYP.6" SMARTSIDEFRIEZE BOARD TYP.VINYL BOARD &BATTEN TYP.VINYL LAP SIDING & VINYL CORNERS ALL SIDES4:12CULTURED STONE W/CONCRETE CAP3' - 6"4" SMARTSIDE TRIM@ WINDOWS & DOORSTYP. -FRONT ONLYADDRESS STONE7:12128SEE COLUMN DETAIL SHEET A-5016" SMARTSIDE STORYBOARD TYP.4' - 0"47:121/4" = 1'-0"A-2011FRONT ELEVATIONTHE IDEAS, DESIGNS, DRAWINGS AND SPECIFICATIONS REPRESENTED HEREIN ARE AND SHALL REMAIN THE EXCLUSIVE COPYRIGHT PROPERTY OF ONETENTEN HOMES. NO PART THERE OF SHALL BE USED, COPIED, OR DISCLOSED IN CONNECTION WITH ANY WORK OR PROJECT OTHER THAN THE SPECIFIED PROJECT FOR WHICH THEY HAVE BEEN PREPARED WITHOUT THE WRITTEN CONSENT OF ONETENTEN HOMES.THE PLANS FURNISHED HEREIN WERE PREPARED UPON REQUEST BY DRAFTSPERSONS WHO ARE NOT REGISTERED ARCHITECTS OR ENGINEERS. ONETENTEN HOMES ASSUMES NO RESPONSIBILITY FOR STRUCTURAL OR DIMENSIONAL ERRORS OR OMISSIONS.THE CONTRACTOR AND/OR OWNER MUST VERIFY AND CHECKALL NOTES DETAILS, ELEVATIONS, SECTIONS AND FLOOR PLANS AND NOTIFY ONETENTEN HOMES OF ANY ERRORS OR OMISSIONS PRIOR TO THE START OF CONSTRUCTION. NO WARRANTIES ARE EXPRESSED OR IMPLIED INCLUDING COMPLIANCE OF THIS PLAN WITH APPLICABLE BUILDING CODE REQUIREMENTS. THE SELECTION AND APPLICATION OF CORRECT STRUCTURAL MATERIALS IS THE RESPONSIBILITY OF THE BUILDER, THE OWNER OR THE USER OF THESE PLANS.DATESQUARE FEETPROJECTSHEETUPPER:MAIN:LOWER:RELEASEDREV. 1REV. 2REV. 3REV. 4REV. 5PLATE HEIGHTSUPPER:MAIN:POUR:P.O. BOX 3915411 LAKERS LANE, SUITE 204NISSWA, MN 56468PH (612) 327-7582NORTHHOUSE-RD.COMBRAINERD LAKESTWIN CITIES3000 COUNTY ROAD 42 WEST, SUITE 202 BURNSVILLE, MN 55337PH (952)-953-4000ONETENTENHOMES.COMUNSPECIFIED HEADERS TO BE 2-2x10 W/ 2 TRIMMERS10" MIN. STAIR TREAD DEPTH & 7 3/4" MAX STAIR RISER HEIGHTALL ANGLES ARE 45 DEGREES UNLESS NOTED OTHERWISEALL EXTERIOR DIMENSIONS ARE TO OUTSIDE OF SHEATHING, CONCRETE OR FOUNDATION INSULATIONTOTAL:TOTAL:4/13/2020 4:46:07 PMSPEC HOMEL31, B4 - KNOB HILL5710 UPPER 179TH STREET WESTLAKEVILLE, MN 55024A-201OTT1254.13.20 CB110610847664.10.20 CB8'-1 1/8"9'-1 1/8"8'-4"PAYTON XL29562956SHEET INDEXSHEET NUMBER SHEET NAMEA-201 ELEVATIONA-202 ELEVATIONS/ ROOF PLANA-401 FOUNDATION PLANA-402 LOWER FLOORA-403 MAIN FLOORA-404 UPPER FLOORA-501 SCHEDULES/ DETAILSA-502 DETAILSConcept Approval ONLYSubject to Field InspectionInspectorDate2015MN BldgCode06/15/2020shutchins 8:128:1212724" RETURNSTYPICAL7:12127ALUMINUM SOFFIT& FASCIA TYP.VINYL SIDING& CORNERS7:121281281278:121247:124:1224" RETURNSTYPICAL8:121274:12STANDARD ENERGY HEELS @ 4:12 & 7:12 PITCH TYP.8:128:128:128:127:127:124:127:127:12HEELS @ 8:12 PITCH TO MATCH18" OVERHANGS & 12" RAKES TYP.6 ROOF VENTS @ HOUSE4 ROOF VENTS @ GARAGE7:128:128:12THE IDEAS, DESIGNS, DRAWINGS AND SPECIFICATIONS REPRESENTED HEREIN ARE AND SHALL REMAIN THE EXCLUSIVE COPYRIGHT PROPERTY OF ONETENTEN HOMES. NO PART THERE OF SHALL BE USED, COPIED, OR DISCLOSED IN CONNECTION WITH ANY WORK OR PROJECT OTHER THAN THE SPECIFIED PROJECT FOR WHICH THEY HAVE BEEN PREPARED WITHOUT THE WRITTEN CONSENT OF ONETENTEN HOMES.THE PLANS FURNISHED HEREIN WERE PREPARED UPON REQUEST BY DRAFTSPERSONS WHO ARE NOT REGISTERED ARCHITECTS OR ENGINEERS. ONETENTEN HOMES ASSUMES NO RESPONSIBILITY FOR STRUCTURAL OR DIMENSIONAL ERRORS OR OMISSIONS.THE CONTRACTOR AND/OR OWNER MUST VERIFY AND CHECKALL NOTES DETAILS, ELEVATIONS, SECTIONS AND FLOOR PLANS AND NOTIFY ONETENTEN HOMES OF ANY ERRORS OR OMISSIONS PRIOR TO THE START OF CONSTRUCTION. NO WARRANTIES ARE EXPRESSED OR IMPLIED INCLUDING COMPLIANCE OF THIS PLAN WITH APPLICABLE BUILDING CODE REQUIREMENTS. THE SELECTION AND APPLICATION OF CORRECT STRUCTURAL MATERIALS IS THE RESPONSIBILITY OF THE BUILDER, THE OWNER OR THE USER OF THESE PLANS.DATESQUARE FEETPROJECTSHEETUPPER:MAIN:LOWER:RELEASEDREV. 1REV. 2REV. 3REV. 4REV. 5PLATE HEIGHTSUPPER:MAIN:POUR:P.O. BOX 3915411 LAKERS LANE, SUITE 204NISSWA, MN 56468PH (612) 327-7582NORTHHOUSE-RD.COMBRAINERD LAKESTWIN CITIES3000 COUNTY ROAD 42 WEST, SUITE 202 BURNSVILLE, MN 55337PH (952)-953-4000ONETENTENHOMES.COMUNSPECIFIED HEADERS TO BE 2-2x10 W/ 2 TRIMMERS10" MIN. STAIR TREAD DEPTH & 7 3/4" MAX STAIR RISER HEIGHTALL ANGLES ARE 45 DEGREES UNLESS NOTED OTHERWISEALL EXTERIOR DIMENSIONS ARE TO OUTSIDE OF SHEATHING, CONCRETE OR FOUNDATION INSULATIONTOTAL:TOTAL:4/13/2020 4:46:09 PMSPEC HOMEL31, B4 - KNOB HILL5710 UPPER 179TH STREET WESTLAKEVILLE, MN 55024A-202OTT1254.13.20 CB110610847664.10.20 CB8'-1 1/8"9'-1 1/8"8'-4"PAYTON XL295629561/8" = 1'-0"A-2021RIGHT ELEVATION1/8" = 1'-0"A-2022REAR ELEVATION1/8" = 1'-0"A-2023LEFT ELEVATION1/8" = 1'-0"A-2024ROOF PLANSecure door closed until deck isconstructed with a separate permit. 48' - 0"1' - 10"19' - 10"20' - 2"11' - 0"18' - 10"31' - 2"50' - 0"28' - 2"19' - 10"14' - 0"5' - 10"3'-6"(H) x 8"(W) POUREDCONCRETE FOUND. WALL W/2" x 8" INTERIOR LEDGE ON16" x 8" CONCRETE FTG'S.REBAR PER CODE.8'-4"(H) x 8"(W) POUREDCONCRETE FOUND. WALL ON20" x 8" CONCRETE FTG'S.REBAR PER CODE.8'-4"(H) x 10"(W) POUREDCONCRETE FOUND. WALL ON20" x 8" CONCRETE FTG'S.REBAR PER CODE.19' - 8"20' - 4"*ALL DIMENSIONS ARE TO OUTSIDE OF CONCRETE48' - 0"15' - 0 1/2"13' - 1 1/2"15' - 8 1/4"3' - 4 1/2"3' - 11 1/4"3' - 11 1/4"13' - 0 3/4"8'-4"(H) x 8"(W) POUREDCONCRETE FOUND. WALL ON20" x 8" CONCRETE FTG'S.REBAR PER CODE.25' - 6"22' - 6"40' - 0"8'-4"(H) x 8"(W) POUREDCONCRETE FOUND. WALL ON20" x 8" CONCRETE FTG'S.REBAR PER CODE.0' - 4"26' - 4"16' - 8"11' - 8"2x6 STUDS @ 16" O.C. ONHALF-HIGH 6" BLOCK ON16" x 8" CONCRETE FTG'S.REBAR PER CODE.2' - 0"20' - 6"1' - 11 1/2"16' - 3" M.O.1' - 11 1/2"1' - 1 1/2"8' - 3" M.O.1' - 7 1/2"7'-8"(H) x 8"(W) POUREDCONCRETE FOUND. WALL ON16" x 8" CONCRETE FTG'S.REBAR PER CODE.:LOOKOUT WALL:2x6 STUDS @ 16" O.C. ON3'-6"(H) x 8"(W) POUREDCONCRETE FOUND. WALL ON20" x 8" CONCRETE FTG.REBAR PER CODE8'-4"(H) x 8"(W) POUREDCONCRETE FOUND. WALL ON20" x 8" CONCRETE FTG'S.REBAR PER CODE.40' - 0"10' - 0"50' - 0"3' - 11"7' - 4"0' - 5"14' - 8"0' - 4"LEAVE A 12"GAP IN THE FOOTING FOR PLUMBINGLEAVE A 12"GAP IN THE FOOTING FOR PLUMBINGTHE IDEAS, DESIGNS, DRAWINGS AND SPECIFICATIONS REPRESENTED HEREIN ARE AND SHALL REMAIN THE EXCLUSIVE COPYRIGHT PROPERTY OF ONETENTEN HOMES. NO PART THERE OF SHALL BE USED, COPIED, OR DISCLOSED IN CONNECTION WITH ANY WORK OR PROJECT OTHER THAN THE SPECIFIED PROJECT FOR WHICH THEY HAVE BEEN PREPARED WITHOUT THE WRITTEN CONSENT OF ONETENTEN HOMES.THE PLANS FURNISHED HEREIN WERE PREPARED UPON REQUEST BY DRAFTSPERSONS WHO ARE NOT REGISTERED ARCHITECTS OR ENGINEERS. ONETENTEN HOMES ASSUMES NO RESPONSIBILITY FOR STRUCTURAL OR DIMENSIONAL ERRORS OR OMISSIONS.THE CONTRACTOR AND/OR OWNER MUST VERIFY AND CHECKALL NOTES DETAILS, ELEVATIONS, SECTIONS AND FLOOR PLANS AND NOTIFY ONETENTEN HOMES OF ANY ERRORS OR OMISSIONS PRIOR TO THE START OF CONSTRUCTION. NO WARRANTIES ARE EXPRESSED OR IMPLIED INCLUDING COMPLIANCE OF THIS PLAN WITH APPLICABLE BUILDING CODE REQUIREMENTS. THE SELECTION AND APPLICATION OF CORRECT STRUCTURAL MATERIALS IS THE RESPONSIBILITY OF THE BUILDER, THE OWNER OR THE USER OF THESE PLANS.DATESQUARE FEETPROJECTSHEETUPPER:MAIN:LOWER:RELEASEDREV. 1REV. 2REV. 3REV. 4REV. 5PLATE HEIGHTSUPPER:MAIN:POUR:P.O. BOX 3915411 LAKERS LANE, SUITE 204NISSWA, MN 56468PH (612) 327-7582NORTHHOUSE-RD.COMBRAINERD LAKESTWIN CITIES3000 COUNTY ROAD 42 WEST, SUITE 202 BURNSVILLE, MN 55337PH (952)-953-4000ONETENTENHOMES.COMUNSPECIFIED HEADERS TO BE 2-2x10 W/ 2 TRIMMERS10" MIN. STAIR TREAD DEPTH & 7 3/4" MAX STAIR RISER HEIGHTALL ANGLES ARE 45 DEGREES UNLESS NOTED OTHERWISEALL EXTERIOR DIMENSIONS ARE TO OUTSIDE OF SHEATHING, CONCRETE OR FOUNDATION INSULATIONTOTAL:TOTAL:4/13/2020 4:46:09 PMSPEC HOMEL31, B4 - KNOB HILL5710 UPPER 179TH STREET WESTLAKEVILLE, MN 55024A-401OTT1254.13.20 CB110610847664.10.20 CB8'-1 1/8"9'-1 1/8"8'-4"PAYTON XL295629561/4" = 1'-0"A-4011FOUNDATION PLANUFER Ground-Provide 20' Rebar in footing and stubup near electrical service panel. UP 16RUNEXCAVATEDFURNACESUMPW. H.F. D.4' VANITYFAMILY ROOMBEDROOM #5BATH25' - 6"22' - 6"1' - 10"19' - 10"20' - 2"11' - 0"18' - 10"31' - 2"28' - 2"19' - 10"16' - 0"5' - 10"4' - 8"CO DET.SMOKEDET.19' - 3 1/2"3' - 8 1/2"3' - 8 1/2"13' - 3 1/2"248" F.G. SHWRCLOSET3314' - 0"5' - 10"11' - 8"16' - 8"UNEXCAVATEDR & SH.2x67' - 7"1' - 11"3' - 8"26' - 10"6' - 9"11' - 0"12' - 9"9' - 6"3-9 1/2" LVLW/ 2 TRIMMERSSMOKEDET.*3-1/2" CONC. FLOOR*MECHANICALS MAY VARY19' - 8"20' - 4"4' - 0" B.W.P.4' - 0" B.W.P.4' - 0" B.W.P.*ALL DIMENSIONS ARE TO OUTSIDE OF CONCRETE/SHEATHING2-2x10 W/2 TRIMMERS2-2x102-2x102-2x102-9 1/2" LSL@ 65"12" CANTILEVERABOVE48' - 0"48' - 0"50' - 0"40' - 0"4' - 3 1/4"7' - 4 3/4"3' - 11"10' - 9"0' - 4"2-2x10 W/2 TRIMMERS 26' - 4"14' - 8"11' - 8"2x6 STUDS @ 16" O.C. ONHALF-HIGH 6" BLOCK ON16" x 8" CONCRETE FTG'S.REBAR PER CODE.814' - 2 1/2"15' - 1"8' - 2"3' - 6"5MECHANICAL2AIR EX.2" FOAM INSULATIONBETWEEN WALL & SLAB1' - 11 1/2"16' - 3" M.O.1' - 11 1/2"1' - 1 1/2"8' - 3" M.O.1' - 7 1/2"2' - 0"20' - 6"3-2x10 W/2 TRIMMERS 40' - 0"10' - 0"50' - 0"8FLOOR GIRDER0' - 4"18" FLOOR TRUSSESPER MFG. SPACING18" FLOOR TRUSSESPER MFG. SPACING1/4" = 1'-0"A-4021LOWER FLOOR PLANTHE IDEAS, DESIGNS, DRAWINGS AND SPECIFICATIONS REPRESENTED HEREIN ARE AND SHALL REMAIN THE EXCLUSIVE COPYRIGHT PROPERTY OF ONETENTEN HOMES. NO PART THERE OF SHALL BE USED, COPIED, OR DISCLOSED IN CONNECTION WITH ANY WORK OR PROJECT OTHER THAN THE SPECIFIED PROJECT FOR WHICH THEY HAVE BEEN PREPARED WITHOUT THE WRITTEN CONSENT OF ONETENTEN HOMES.THE PLANS FURNISHED HEREIN WERE PREPARED UPON REQUEST BY DRAFTSPERSONS WHO ARE NOT REGISTERED ARCHITECTS OR ENGINEERS. ONETENTEN HOMES ASSUMES NO RESPONSIBILITY FOR STRUCTURAL OR DIMENSIONAL ERRORS OR OMISSIONS.THE CONTRACTOR AND/OR OWNER MUST VERIFY AND CHECKALL NOTES DETAILS, ELEVATIONS, SECTIONS AND FLOOR PLANS AND NOTIFY ONETENTEN HOMES OF ANY ERRORS OR OMISSIONS PRIOR TO THE START OF CONSTRUCTION. NO WARRANTIES ARE EXPRESSED OR IMPLIED INCLUDING COMPLIANCE OF THIS PLAN WITH APPLICABLE BUILDING CODE REQUIREMENTS. THE SELECTION AND APPLICATION OF CORRECT STRUCTURAL MATERIALS IS THE RESPONSIBILITY OF THE BUILDER, THE OWNER OR THE USER OF THESE PLANS.DATESQUARE FEETPROJECTSHEETUPPER:MAIN:LOWER:RELEASEDREV. 1REV. 2REV. 3REV. 4REV. 5PLATE HEIGHTSUPPER:MAIN:POUR:P.O. BOX 3915411 LAKERS LANE, SUITE 204NISSWA, MN 56468PH (612) 327-7582NORTHHOUSE-RD.COMBRAINERD LAKESTWIN CITIES3000 COUNTY ROAD 42 WEST, SUITE 202 BURNSVILLE, MN 55337PH (952)-953-4000ONETENTENHOMES.COMUNSPECIFIED HEADERS TO BE 2-2x10 W/ 2 TRIMMERS10" MIN. STAIR TREAD DEPTH & 7 3/4" MAX STAIR RISER HEIGHTALL ANGLES ARE 45 DEGREES UNLESS NOTED OTHERWISEALL EXTERIOR DIMENSIONS ARE TO OUTSIDE OF SHEATHING, CONCRETE OR FOUNDATION INSULATIONTOTAL:TOTAL:4/13/2020 4:46:10 PMSPEC HOMEL31, B4 - KNOB HILL5710 UPPER 179TH STREET WESTLAKEVILLE, MN 55024A-402OTT1254.13.20 CB110610847664.10.20 CB8'-1 1/8"9'-1 1/8"8'-4"PAYTON XL29562956CS-WSP METHOD BRACED WALL PANELS-8d NAILS 6" ON EDGES & 12" IN FIELD,STACK BETWEEN LEVELS WHEN POSSIBLE.USE (3) 16d NAILS NEXT TO EACHSTUD TO SECURE WALL DOWN TO DECKAT BRACED WALL PANELS.EXPOSURE CATEGORY BASSUMED BRACED WALL NOTESLoaded for Future Deckper Headers Marked PlanBWP above UP 17RDN 16RDN 3RDN 3R22' - 6"25' - 6"28' - 0"20' - 0"50' - 0"8KITCHENDINING ROOMGREAT ROOMFOYEROFFICEMUD RM.DW30" RANGEGARAGEPORCH115' - 11"5' - 0"17' - 1"6' - 0"14' - 0"18' - 10"31' - 2"20' - 2"11' - 0"9' - 6"12' - 6"11' - 3"6' - 9"2' - 0"6' - 0"14' - 0"50' - 0"2' - 1"16' - 0"2' - 1"1' - 3"8' - 0"1' - 9"0' - 10"5' - 2"1' - 0"11' - 0"7' - 4"SMOKEDET.4" CONCRETE SLAB, SLOPETOWARDS DOORS5/8" TYPE X GYP. BD. ALL COMMONWALLS & CEILINGGARAGE PLATE HEIGHT TOMATCH MAIN FLOOR PLATE2-11 7/8" LSL4' - 2"4' - 0"12" CANT.ABOVE3' - 10"9' - 0"6' - 6"SEE COLUMN DETAIL SHEET A-5014' - 4"5' - 10"0' - 10"15' - 0"3-2x10 W/2 TRIMMERS2-9 1/2" LSL W/3 TRIMMERSDROPPED 2-2x10 CONT.TYP.0' - 4 1/2"20' - 6"2' - 0"62-2x1210' - 0"40' - 0"SNACK BAR19' - 4"20' - 8"4' - 0"1' - 4"PORTAL FRAME W/ HOLD DOWN3' - 0" B.W.P.4' - 0" B.W.P.4' - 0" B.W.P.4' - 0" B.W.P.3' - 0" B.W.P.3' - 0" B.W.P.3' - 0" B.W.P.3' - 0" B.W.P.SINKSET FIREPLACE @ F.F.HALF HIGH TILEWRAPPED TO EXTERIOR WALL W/ WRAPPED MANTELPOWDER36" REF272-2X102-2X10 W/2 TRIMMERS2-2X102-11 7/8"LSL FLUSH W/3 TRIMMERS2-2X10 W/2 TRIMMERSPORTAL FRAME W/ HOLD DOWN2-2X102-2X102-2X103' - 0" B.W.P.3' - 0" B.W.P.3' - 0" B.W.P.3' - 0" B.W.P.3' - 0" B.W.P.3' - 0" B.W.P.5' - 0" B.W.P.2-2X1048' - 0"7' - 5"18' - 7"3' - 2 3/4"5' - 6"3' - 2"1' - 0"3' - 9"2' - 0"3' - 4"4' - 2 1/4"12' - 8 3/4"12' - 2"19' - 8"3' - 8"4' - 6"11' - 6"16' - 6"19' - 3 1/2"3' - 8 1/2"3' - 8 1/2"13' - 3 1/2"2-2X102-9 1/2" LSL24" CANTILEVER ABOVE26' - 0"9' - 7 1/2"11' - 0 1/2"40' - 0"KNEE WALL W/14" SPINDLES2-2X102-11 7/8"LSL FLUSH W/3 TRIMMERS2-11 7/8"LSL FLUSHW/ 2 TRIMMERS99" HEAT DUCT2' - 0"2' - 0"14' - 3"2' - 10"3' - 1"2' - 10"EQEQ121212766113ATTICACCESSR & SH.B.W.P.4' - 0"16" SH.16" SH.B.W.P.2' - 0"B.W.P.2' - 0"B.W.P.1' - 9"PAINTED CABINETSFULL TILEBACKSPLASH1121048' - 0"5' - 0" B.W.P.2CLOSETPED. SINK4' - 6"2' - 6"4' - 4"GAS LINE FOR RANGEGAS F.P.1' - 0"HUC412HUC41211' - 4"14' - 8"18" FLOOR TRUSSESPER MFG. SPACING18" FLOOR TRUSSESPER MFG. SPACINGMFG. ROOF TRUSSES@ 24" O.C.MFG. ROOF TRUSSES@ 24" O.C.1/4" = 1'-0"A-4031MAIN FLOOR PLANTHE IDEAS, DESIGNS, DRAWINGS AND SPECIFICATIONS REPRESENTED HEREIN ARE AND SHALL REMAIN THE EXCLUSIVE COPYRIGHT PROPERTY OF ONETENTEN HOMES. NO PART THERE OF SHALL BE USED, COPIED, OR DISCLOSED IN CONNECTION WITH ANY WORK OR PROJECT OTHER THAN THE SPECIFIED PROJECT FOR WHICH THEY HAVE BEEN PREPARED WITHOUT THE WRITTEN CONSENT OF ONETENTEN HOMES.THE PLANS FURNISHED HEREIN WERE PREPARED UPON REQUEST BY DRAFTSPERSONS WHO ARE NOT REGISTERED ARCHITECTS OR ENGINEERS. ONETENTEN HOMES ASSUMES NO RESPONSIBILITY FOR STRUCTURAL OR DIMENSIONAL ERRORS OR OMISSIONS.THE CONTRACTOR AND/OR OWNER MUST VERIFY AND CHECKALL NOTES DETAILS, ELEVATIONS, SECTIONS AND FLOOR PLANS AND NOTIFY ONETENTEN HOMES OF ANY ERRORS OR OMISSIONS PRIOR TO THE START OF CONSTRUCTION. NO WARRANTIES ARE EXPRESSED OR IMPLIED INCLUDING COMPLIANCE OF THIS PLAN WITH APPLICABLE BUILDING CODE REQUIREMENTS. THE SELECTION AND APPLICATION OF CORRECT STRUCTURAL MATERIALS IS THE RESPONSIBILITY OF THE BUILDER, THE OWNER OR THE USER OF THESE PLANS.DATESQUARE FEETPROJECTSHEETUPPER:MAIN:LOWER:RELEASEDREV. 1REV. 2REV. 3REV. 4REV. 5PLATE HEIGHTSUPPER:MAIN:POUR:P.O. BOX 3915411 LAKERS LANE, SUITE 204NISSWA, MN 56468PH (612) 327-7582NORTHHOUSE-RD.COMBRAINERD LAKESTWIN CITIES3000 COUNTY ROAD 42 WEST, SUITE 202 BURNSVILLE, MN 55337PH (952)-953-4000ONETENTENHOMES.COMUNSPECIFIED HEADERS TO BE 2-2x10 W/ 2 TRIMMERS10" MIN. STAIR TREAD DEPTH & 7 3/4" MAX STAIR RISER HEIGHTALL ANGLES ARE 45 DEGREES UNLESS NOTED OTHERWISEALL EXTERIOR DIMENSIONS ARE TO OUTSIDE OF SHEATHING, CONCRETE OR FOUNDATION INSULATIONTOTAL:TOTAL:4/13/2020 4:46:11 PMSPEC HOMEL31, B4 - KNOB HILL5710 UPPER 179TH STREET WESTLAKEVILLE, MN 55024A-403OTT1254.13.20 CB110610847664.10.20 CB8'-1 1/8"9'-1 1/8"8'-4"PAYTON XL29562956CS-WSP METHOD BRACED WALL PANELS-8d NAILS 6" ON EDGES & 12" IN FIELD,STACK BETWEEN LEVELS WHEN POSSIBLE.USE (3) 16d NAILS NEXT TO EACHSTUD TO SECURE WALL DOWN TO DECKAT BRACED WALL PANELS.EXPOSURE CATEGORY BASSUMED BRACED WALL NOTESHHUS410HHUS410(3) 2x6(2) 2x6(3) 2x6BWP aboveBWP abovePFHPFHPFH DN 17RBEDROOM #4LAUNDRYBEDROOM #3OWNER'S SUITEHALL1/2 WALL W/WOOD CAPSMOKEDET.SMOKEDET.EN SUITE6' VANITYCLOSETR & SH.3SMOKEDET.53R & SH.3BEDROOM #2GIRDER TRUSSCO DET.SMOKEDET.ATTICACCESS2' LINEN344:124:12GIRDERTRUSS13' - 0"27' - 0"3' - 0"28' - 0"29' - 0"2' - 0"26' - 6"13' - 6"R & SH.226' - 4"14' - 6"5' - 8"6' - 9"6' - 9"3CLOSETBATH2x63' VANITYR & SH.20' - 6"26' - 6"6' - 6"2' - 6"7' - 6"17' - 0"VAULT LINE2-2x10 W/2 TRIMMERS2-2x102-2x102-2x102-2x102' - 3" B.W.P.2' - 3" B.W.P.2' - 3" B.W.P.2' - 3" B.W.P.2' - 3" B.W.P.2' - 3" B.W.P.2' - 3" B.W.P.2' - 3" B.W.P.3' - 0" B.W.P.2' - 3" B.W.P.2' - 3" B.W.P.2' - 3" B.W.P.2' - 3" B.W.P.40' - 0"5' - 9"22' - 3"40' - 0"8' - 0"5' - 5"4' - 3"1' - 8"4' - 8"5' - 0"8' - 5"2' - 6"1' - 9 1/2"0' - 9 1/2"14' - 6"9' - 2"3' - 6"2' - 6"11' - 8 1/4"3' - 4"3' - 1"6' - 8 3/4"19' - 3 1/2"3' - 8 1/2"3' - 8 1/2"13' - 3 1/2"4' - 4"5' - 0"0' - 10"15' - 10"48" F.G.SHOWER W/ C.T. WALLS& BY-PASSDOORS@ 65"@ 65"@ 65"@ 65"2-2x102-2x10 W/2 TRIMMERS533109925' TUB/SHWRSMOKEDET.6' -10" H.H.6' -10" H.H.WASHERDRYERDBL FRAMED FOR PLUMBING WALL3' x 5' TUB W/ TILEDECKKNEE WALL W/14" SPINDLES31' - 0"31' - 0"MFG. ROOF TRUSSES@ 24" O.C.MFG. ROOF TRUSSES@ 24" O.C.MFG. ROOF TRUSSES@ 24" O.C.MFG. ROOF TRUSSES@ 24" O.C.THE IDEAS, DESIGNS, DRAWINGS AND SPECIFICATIONS REPRESENTED HEREIN ARE AND SHALL REMAIN THE EXCLUSIVE COPYRIGHT PROPERTY OF ONETENTEN HOMES. NO PART THERE OF SHALL BE USED, COPIED, OR DISCLOSED IN CONNECTION WITH ANY WORK OR PROJECT OTHER THAN THE SPECIFIED PROJECT FOR WHICH THEY HAVE BEEN PREPARED WITHOUT THE WRITTEN CONSENT OF ONETENTEN HOMES.THE PLANS FURNISHED HEREIN WERE PREPARED UPON REQUEST BY DRAFTSPERSONS WHO ARE NOT REGISTERED ARCHITECTS OR ENGINEERS. ONETENTEN HOMES ASSUMES NO RESPONSIBILITY FOR STRUCTURAL OR DIMENSIONAL ERRORS OR OMISSIONS.THE CONTRACTOR AND/OR OWNER MUST VERIFY AND CHECKALL NOTES DETAILS, ELEVATIONS, SECTIONS AND FLOOR PLANS AND NOTIFY ONETENTEN HOMES OF ANY ERRORS OR OMISSIONS PRIOR TO THE START OF CONSTRUCTION. NO WARRANTIES ARE EXPRESSED OR IMPLIED INCLUDING COMPLIANCE OF THIS PLAN WITH APPLICABLE BUILDING CODE REQUIREMENTS. THE SELECTION AND APPLICATION OF CORRECT STRUCTURAL MATERIALS IS THE RESPONSIBILITY OF THE BUILDER, THE OWNER OR THE USER OF THESE PLANS.DATESQUARE FEETPROJECTSHEETUPPER:MAIN:LOWER:RELEASEDREV. 1REV. 2REV. 3REV. 4REV. 5PLATE HEIGHTSUPPER:MAIN:POUR:P.O. BOX 3915411 LAKERS LANE, SUITE 204NISSWA, MN 56468PH (612) 327-7582NORTHHOUSE-RD.COMBRAINERD LAKESTWIN CITIES3000 COUNTY ROAD 42 WEST, SUITE 202 BURNSVILLE, MN 55337PH (952)-953-4000ONETENTENHOMES.COMUNSPECIFIED HEADERS TO BE 2-2x10 W/ 2 TRIMMERS10" MIN. STAIR TREAD DEPTH & 7 3/4" MAX STAIR RISER HEIGHTALL ANGLES ARE 45 DEGREES UNLESS NOTED OTHERWISEALL EXTERIOR DIMENSIONS ARE TO OUTSIDE OF SHEATHING, CONCRETE OR FOUNDATION INSULATIONTOTAL:TOTAL:4/13/2020 4:46:12 PMSPEC HOMEL31, B4 - KNOB HILL5710 UPPER 179TH STREET WESTLAKEVILLE, MN 55024A-404OTT1254.13.20 CB110610847664.10.20 CB8'-1 1/8"9'-1 1/8"8'-4"PAYTON XL295629561/4" = 1'-0"A-4041UPPER FLOOR PLANCS-WSP METHOD BRACED WALL PANELS-8d NAILS 6" ON EDGES & 12" IN FIELD,STACK BETWEEN LEVELS WHEN POSSIBLE.USE (3) 16d NAILS NEXT TO EACHSTUD TO SECURE WALL DOWN TO DECKAT BRACED WALL PANELS.EXPOSURE CATEGORY BASSUMED BRACED WALL NOTES(3) 2x6 each end(3) 2x6(2) 2x6(2) 2x6 WATCH DOG WATER PROOF COATINGFROM FOOTING TOSILL SEALER6 MIL POLY V.B., OVERLAPEDGES MIN. 12" & TAPE.SEAL ALL OPENINGS4" MIN. LAYER3/4" RIVER ROCK3 1/2" CONCRETE SLABANCHOR BOLTPER CODETRT'D 2x8 SILL PLATEW/ CLOSED CELL ROLLSILL SEALERGRADEGRANULAR FILL4" DRAIN TILEW/ SILT SOCK1" FOAMBOARD (R-5) INSULATIONW/ ACOUSTICAL SEALANT @ TOP& BOTTOM EDGES, BETWEEN INSUL.& SLAB & AT ALL VERTICAL EDGESPOLYURETHANE CAULKOR ELASTOMERICSEALANT @ ALL JOINTSMIN.0' - 6"VERIFY FLOOR SYSTEMWITH FLOOR PLANS3/4" T&GSUBFLOORLOWER PLATE HEIGHT8' - 2"MAIN FLOOR PLATE HEIGHT9' - 1 1/8"6 MIL. V.B.1/2" GYP. BD.VERIFY FLOOR SYSTEMWITH FLOOR PLANSUPPER FLOOR PLATE HEIGHT8' - 1 1/8"6 MIL. V.B.1/2" GYP. BD.3/4" T&GSUBFLOOR6 MIL. V.B.2x6 STUDS @ 16" O.C.W/ R-21 F.G. INSULATION2x6 STUDS @ 16" O.C.W/ R-21 F.G. INSULATION8'-4"(H) x 8"(W) POUREDCONCRETE FOUND. WALL ON20" x 8" CONCRETE FTG'S.REBAR PER CODE.1/2" OSBSHEATHINGTYVEK (OR EQUAL)ROLL HOUSE WRAPSIDING, VERIFYW/ ELEVATIONS5/8" GYP. BD.5/8" GYP. BD.VENTED ALUMINUMSOFFIT PANELSICE & WATER GUARDFROM EAVE TO 2'-0"MIN. OVER STRUCTUREVENT CHUTES & WIND WASH@ EACH TRUSS SPACEASPHALT SHINGLES W/15# ROLL FELT UNDER1/2" OSB ROOF SHEATHINGMFG. ROOFTRUSSES @ 24" O.C.ATTIC VENTINGAS PER CODER-49 MIN. BLOWNATTIC INSULATIONALUMINUM FASCIA W/2x6 SUB FASCIAALUMINUMDRIP EDGERIM JOISTRIM JOISTR-20 MIN. SPRAYFOAM INSULATION,COVER FOUNDATION WALLGMX THERMAL DRAINAGE BOARD(R-10) INSULATIONDRYVIT INSULATIONPROTECTION FROM SIDINGTO 6" BELOW GRADE5000 PSI CONCRETE@ ALL FOOTINGS*OUTSIDE OF FOUNDATION TO ALIGN WITH OUTSIDE OF SHEATINGR-20 MIN. SPRAYFOAM INSULATION1' - 5"0' - 9 1/2"2x4 @ BOTTOM1x3 TYP.2x22x4 @ TOPSMOOTH LPSMARTSIDE TYP.SOFFIT1' - 9 1/2"1' - 0"FRONTSIDETOP VIEW1' - 5"0' - 9 1/2"FRAMING4x4 POSTTHE IDEAS, DESIGNS, DRAWINGS AND SPECIFICATIONS REPRESENTED HEREIN ARE AND SHALL REMAIN THE EXCLUSIVE COPYRIGHT PROPERTY OF ONETENTEN HOMES. NO PART THERE OF SHALL BE USED, COPIED, OR DISCLOSED IN CONNECTION WITH ANY WORK OR PROJECT OTHER THAN THE SPECIFIED PROJECT FOR WHICH THEY HAVE BEEN PREPARED WITHOUT THE WRITTEN CONSENT OF ONETENTEN HOMES.THE PLANS FURNISHED HEREIN WERE PREPARED UPON REQUEST BY DRAFTSPERSONS WHO ARE NOT REGISTERED ARCHITECTS OR ENGINEERS. ONETENTEN HOMES ASSUMES NO RESPONSIBILITY FOR STRUCTURAL OR DIMENSIONAL ERRORS OR OMISSIONS.THE CONTRACTOR AND/OR OWNER MUST VERIFY AND CHECKALL NOTES DETAILS, ELEVATIONS, SECTIONS AND FLOOR PLANS AND NOTIFY ONETENTEN HOMES OF ANY ERRORS OR OMISSIONS PRIOR TO THE START OF CONSTRUCTION. NO WARRANTIES ARE EXPRESSED OR IMPLIED INCLUDING COMPLIANCE OF THIS PLAN WITH APPLICABLE BUILDING CODE REQUIREMENTS. THE SELECTION AND APPLICATION OF CORRECT STRUCTURAL MATERIALS IS THE RESPONSIBILITY OF THE BUILDER, THE OWNER OR THE USER OF THESE PLANS.DATESQUARE FEETPROJECTSHEETUPPER:MAIN:LOWER:RELEASEDREV. 1REV. 2REV. 3REV. 4REV. 5PLATE HEIGHTSUPPER:MAIN:POUR:P.O. BOX 3915411 LAKERS LANE, SUITE 204NISSWA, MN 56468PH (612) 327-7582NORTHHOUSE-RD.COMBRAINERD LAKESTWIN CITIES3000 COUNTY ROAD 42 WEST, SUITE 202 BURNSVILLE, MN 55337PH (952)-953-4000ONETENTENHOMES.COMUNSPECIFIED HEADERS TO BE 2-2x10 W/ 2 TRIMMERS10" MIN. STAIR TREAD DEPTH & 7 3/4" MAX STAIR RISER HEIGHTALL ANGLES ARE 45 DEGREES UNLESS NOTED OTHERWISEALL EXTERIOR DIMENSIONS ARE TO OUTSIDE OF SHEATHING, CONCRETE OR FOUNDATION INSULATIONTOTAL:TOTAL:4/13/2020 4:46:13 PMSPEC HOMEL31, B4 - KNOB HILL5710 UPPER 179TH STREET WESTLAKEVILLE, MN 55024A-501OTT1254.13.20 CB110610847664.10.20 CB8'-1 1/8"9'-1 1/8"8'-4"PAYTON XL295629563" MIN. ABS OR PVC GASTIGHTPIPE FROM SUBSLAB TOMIN. 12" ABOVE ROOF, MUSTBE RUN THRU CONDITIONED SPACE.PIPE CAN BE CONNECTED TOSUMP SYSTEM OR HAVE"T" FITTING (MIN. 10'-0" EA. WAY)IN GRAVEL UNDER SLAB.END OF PIPE MUST BE MIN. 10'-0"AWAY FROM ANY WINDOW OROTHER OPENING THAT IS LESSTHAN 2'-0" BELOW END OF PIPE. END OF PIPE MUST ALSO BEMIN. 10'-0" AWAY FROM ANYWINDOW OR OTHER OPENING INADJOINING OR ADJACENTBUILDINGS.SUFFICIENT SPACE MUST BELEFT AROUND PIPE IN ATTIC SPACETO ADD FAN. SPACE MUST BEMIN. ∅24" CENTERED ON AXIS OFPIPE W/ MIN. 3'-0" VERTICAL SPACE.A SINGLE PIPE CAN BE USED IF ALLSOIL GASES IN DWELLING CANFLOW FREELY BETWEEN ALL LEVELSOF FOUNDATION. THIS INCLUDESINTERIOR FOOTINGS & OTHERBARRIERS IF AIRFLOW HASBEEN ESTABLISHED.LABEL THE VENT PIPE AT LEASTONCE PER FLOOR AND INACCESSIBLE ATTICS WITH"RADON REDUCTION SYSTEM".ONE ELECTRICAL RECEPTACLE ISREQUIRED IN THE ATTIC NEARTHE VENT PIPE FOR OPT. FAN.:PASSIVE RADON SYSTEM:3/8" = 1'-0"A-5012TYP. WALL SECTIONWINDOW SCHEDULETYPE MARK MANUFACTURER MODEL COUNT UNIT ROUGH WIDTH ROUGH HEIGHT HEAD HEIGHT COMMENTS1 WINDSOR NEXT DIMENSION 1 24-48-2442 SL 8' - 0" 3' - 6" 6' - 10"2 WINDSOR NEXT DIMENSION 1 24-48-2460 SL 8' - 0" 5' - 0" 6' - 10"3 WINDSOR NEXT DIMENSION 3 2424 AWN 2' - 0" 2' - 0" 6' - 10"4 WINDSOR NEXT DIMENSION 1 2424 AWN FIXED 2' - 0" 2' - 0"2' - 6"5 WINDSOR NEXT DIMENSION 1 2424-2 FIXED 4' - 0" 2' - 0" 6' - 10"6 WINDSOR NEXT DIMENSION 2 3618 PIC 3' - 0" 1' - 6" 8' - 0"7 WINDSOR NEXT DIMENSION 1 4242 SL 3' - 6" 3' - 6" 6' - 10"8 WINDSOR NEXT DIMENSION 2 6042 SL 5' - 0" 3' - 6" 6' - 10"9 WINDSOR NEXT DIMENSION 2 6048 SL 5' - 0" 4' - 0" 6' - 10"10 WINDSOR NEXT DIMENSION 1 6060 SL 5' - 0" 5' - 0" 6' - 10"11 WINDSOR NEXT DIMENSION 1 7260 SL 6' - 0" 5' - 0" 6' - 10"12 WINDSOR NEXT DIMENSION 3 P4260/AR24 T 4' - 0" 7' - 0" 8' - 0"1/2" = 1'-0"A-5013TYP. COLUMNROOM FINISH SCHEDULEFLOOR ROOM NAME FLOOR FINISH AREA CEILING HEIGHT COMMENTSLOWER FLOOR FAMILY ROOM CARPET 411 SF 8' - 2" .LOWER FLOOR BEDROOM #5 CARPET 146 SF 8' - 2" .LOWER FLOOR CLOSET CARPET 65 SF 8' - 2" .LOWER FLOOR MECHANICAL UNFINISHED 182 SF 8' - 2" .LOWER FLOOR BATH VINYL 48 SF 8' - 2" .MAIN FLOOR OFFICE CARPET 122 SF 9' - 1 1/8" .MAIN FLOOR PORCH CONCRETE 113 SF 9' - 1 1/8" .MAIN FLOOR GARAGE UNFINISHED 627 SF 10' - 9 3/8"MAIN FLOOR MUD RM. VINYL 48 SF 9' - 1 1/8" .MAIN FLOOR POWDER VINYL 30 SF 9' - 1 1/8" .MAIN FLOOR CLOSET VINYL 31 SF 9' - 1 1/8" .MAIN FLOOR KITCHEN WOOD 191 SF 9' - 1 1/8" .MAIN FLOOR DINING ROOM WOOD 138 SF 9' - 1 1/8" .MAIN FLOOR GREAT ROOM WOOD 244 SF 9' - 1 1/8" .MAIN FLOOR FOYER WOOD 90 SF 9' - 1 1/8" .UPPER FLOOR BEDROOM #4 CARPET 143 SF 8' - 1 1/8" .UPPER FLOOR BEDROOM #3 CARPET 139 SF 8' - 1 1/8" .UPPER FLOOR OWNER'S SUITE CARPET 181 SF 8' - 1 1/8" VAULTEDUPPER FLOOR HALL CARPET 147 SF 8' - 1 1/8" .UPPER FLOOR BEDROOM #2 CARPET 133 SF 8' - 1 1/8" .UPPER FLOOR CLOSET CARPET 55 SF 8' - 1 1/8" .UPPER FLOOR CLOSET CARPET 27 SF 8' - 1 1/8" .UPPER FLOOR LAUNDRY VINYL 30 SF 8' - 1 1/8" .UPPER FLOOR EN SUITE VINYL 91 SF 8' - 1 1/8" .UPPER FLOOR BATH VINYL 43 SF 8' - 1 1/8" .DOOR SCHEDULETYPE MARK DOOR SIZE COUNT COMMENTS1 2/0 x 6/8 12 2/4 x 6/8 83 2/6 x 6/8 74 2/6 x 6/8 PKT 15 2/8 x 6/8 26 2/8 x 6/8 FIRE RATED 17 3/0 x 6/8 OPG. 18 3/0 x 6/8 W/ 12" D.S. SL'S 19 5/0 x 6/8 OPG. 110 8' x 8' O.H. GARAGE DOOR 111 12" TRANSOM / 6/0 x 6/8 SLIDER 112 16' x 8' O.H. GARAGE DOOR 1 6 MIL POLY V.B., OVERLAPEDGES MIN. 12" & TAPE.SEAL ALL OPENINGS4" MIN. LAYER3/4" RIVER ROCK3 1/2" CONCRETE SLABANCHOR BOLTPER CODETYPICAL 2x6EXTERIOR WALLTRT'D 2x6 SILL PLATEW/ ROLL SILL SEALERGRADEGRANULAR FILL:WALKOUT WALL:2x6 STUDS @ 16" O.C. ON3'-6"(H) x 8"(W) POUREDCONCRETE FOUND. WALLW/ 2" x 4" INT. LEDGE ON20" x 8" CONCRETE FTG'S.REBAR PER CODE.POLYURETHANE CAULKOR ELASTOMERICSEALANT @ ALL JOINTSMIN.0' - 6"5000 PSI CONCRETE@ ALL FOOTINGS2" FOAMBOARD(R-10) INSULATION4" DRAIN TILEW/ SILT SOCKWATER PROOF COATING FROM FOOTING TOSILL SEALERANCHOR BOLTPER CODETRT'D 2x6 SILL PLATEW/ ROLL SILL SEALER1" FOAMBOARD (R-5) INSULATIONW/ ACOUSTICAL SEALANT @ TOP& BOTTOM EDGES, BETWEEN INSUL.& SLAB & AT ALL VERTICAL EDGESVERIFY FLOOR SYSTEMWITH FLOOR PLANS3/4" T&GSUBFLOOR6 MIL. V.B.1/2" GYP. BD.2x6 STUDS @ 16" O.C.W/ R-20 F.G. INSULATION1/2" OSBSHEATHINGRIM JOISTR-20 MIN. SPRAYFOAM INSULATIONGMX THERMAL DRAINAGE BOARD(R-10) INSULATION5/8" GYP. BD., TAPE& MUD ALL SEAMSSLOPED CONCRETESTOOP, FLASH AS REQ'DAT HOUSE WALLPOUREDFND. WALLWATCH DOG WATER PROOFCOATING FROM FOOTING TOSILL SEALERSIDING, VERIFYW/ ELEVATIONSTYVEK (OR EQUAL) ROLL HOUSE WRAP0' - 2"FROM SHEATHING TOOUTSIDE OF FOUNDATIONANCHOR BOLTPER CODETRT'D 2x6 SILL PLATEW/ ROLL SILL SEALER1" FOAMBOARD (R-5) INSULATIONW/ ACOUSTICAL SEALANT @ TOP& BOTTOM EDGES, BETWEEN INSUL.& SLAB & AT ALL VERTICAL EDGES3/4" T&GSUBFLOOR6 MIL. V.B.1/2" GYP. BD.2x6 STUDS @ 16" O.C.W/ R-20 F.G. INSULATION5/8" TYPE 'X' GYP BOARD,TAPE & MUD ALL SEAMSRIM JOISTR-20 MIN. SPRAYFOAM INSULATIONGMX THERMAL DRAINAGE BOARD(R-10) INSULATION5/8" GYP. BD., TAPE& MUD ALL SEAMSSLOPED CONCRETESLAB, FLASH AS REQ'DAT HOUSE WALL0' - 4"POUREDFND. WALLWATCH DOG WATER PROOFCOATING FROM FOOTING TOSILL SEALERVERIFY FLOOR SYSTEMWITH FLOOR PLANSFASTEN TOP PLATE TOHEADER W/ (2) ROWS OF16d SINKER NAILS @3" O.C. TYP.MIN. 3/8" WOODSTRUCTURAL PANELSHEATHINGSECTIONTENSION STRAP PERTABLE R602.10.6.4(ON OPPOSITE SIDEOF SHEATHING)IF NEEDED, PANELSPLICE EDGES SHALLOCCUR OVER AND BENAILED TO COMMONBLOCKING WITHINMIDDLE 24" OF WALLMID-HEIGHT. ONEROW OF 3" O.C.NAILING IS REQUIREDIN EACH PANEL EDGE.TYPICAL PORTALFRAME CONSTRUCTION.MIN. DOUBLE 2x4 POST(KING AND JACK STUD).NUMBER OF JACK STUDSPER TABLES R502.5(1) & (2).MIN. 1000 LB HOLD-DOWNDEVICE (EMBEDDED INTOCONCRETE & NAILEDINTO FRAMING)FRONT ELEVATIONMIN. FOOTING SIZE UNDER OPENING IS12" X 12". A TURNED DOWN SLAB SHALLBE PERMITTED AT DOOR OPENINGS.MIN. (1) 5/8" DIA. ANCHOR BOLDINSTALLED PER R403.1.6 W/2" X 2" X 3/16" PLATE WASHER.MIN. REINFORCING OF FOUNDATION,ONE #4 BAR TOP & BOTTOM OFFOOTING. LAP BARS 15" MINIMUM.MIN. (2) 4200 LB STRAP-TYPE HOLD-DOWNS (EMBEDDED INTO CONCRETEAND NAILED INTO FRAMING)MIN. LENGTH OF PANELPER TABLE R602.10.5MIN. DOUBLE 2x4 FRAMING COVEREDWITH MIN. 3/8" THICK WOOD STRUCTURALPANEL SHEATHING W/ 8d COMMON ORGALVANIZED BOX NAILS AT 3" O.C. INALL FRAMING (STUDS, BLOCKING AND SILLS) TYP.HEADER TO JACK STUD STRAP PERTABLE R602.10.6.4 ON BOTH SIDES OFOPENING OPPOSITE SIDE OF SHEATHINGFASTEN SHEATHING TO HEADER WITH8d COMMON OR GALVANIZED BOXNAILS IN 3" GRID PATTERN AS SHOWNMIN. 3" X 11 1/4" NET HEADER,STEEL HEADER PROHIBITED9' - 11 1/4" MAX. HEIGHTHEIGHTPONYWALL12' - 0" MAX TOTAL WALL HEIGHTEXTENT OF HEADER WITH SINGLE PORTALFRAME (ONE BRACED WALL PANEL)2' - 0" TO 18' - 0" FINISHED WIDTH OFOPENING FOR SINGLE OR DOUBLE PORTAL2x6 STUDS @ 16" O.C. ONHALF-HIGH 6" BLOCK ON16" x 8" CONCRETE FTG'S.REBAR PER CODE.TRT'D SILL PLATEPOLYURETHANE CAULKOR ELASTOMERICSEALANT @ ALL JOINTSSLEEVE EVERY10'-0" MIN.6 MIL POLY V.B., OVERLAPEDGES MIN. 12" & TAPE.SEAL ALL OPENINGS4" MIN. LAYER3/4" RIVER ROCK3 1/2" CONCRETE SLABANCHOR BOLTPER CODE5000 PSI CONCRETE@ ALL FOOTINGSWATER PROOF COATINGFROM FOOTING TOINSIDE OF WALL6 MIL POLY V.B., OVERLAPEDGES MIN. 12" & TAPE.SEAL ALL OPENINGS4" MIN. LAYER3/4" RIVER ROCK3 1/2" CONCRETE SLABANCHOR BOLTPER CODETYPICAL 2x6EXTERIOR WALLTRT'D 2x6 SILL PLATEW/ ROLL SILL SEALERGRADEMIN.0' - 6"GRANULAR FILL4" DRAIN TILEW/ SILT SOCK:LOOKOUT WALL:2x6 STUDS @ 16" O.C. ON3'-6"(H) x 8"(W) POUREDCONCRETE FOUND. WALL ON20" x 8" CONCRETE FTG.REBAR PER CODEPOLYURETHANE CAULKOR ELASTOMERICSEALANT @ ALL JOINTS1" FOAMBOARD (R-5) INSULATIONW/ ACOUSTICAL SEALANT @ TOP& BOTTOM EDGES, BETWEEN INSUL.& SLAB & AT ALL VERTICAL EDGESINSULATION & SEALANT TOBE CONT. OVER WALL2" FOAMBOARD(R-10) INSULATIONDRYVIT INSULATION PROTECTIONFROM SIDING TO6" BELOW GRADE5000 PSI CONCRETE@ ALL FOOTINGS*OUTSIDE OF FOUNDATION TO ALIGN WITHOUTSIDE OF SHEATHINGTHE IDEAS, DESIGNS, DRAWINGS AND SPECIFICATIONS REPRESENTED HEREIN ARE AND SHALL REMAIN THE EXCLUSIVE COPYRIGHT PROPERTY OF ONETENTEN HOMES. NO PART THERE OF SHALL BE USED, COPIED, OR DISCLOSED IN CONNECTION WITH ANY WORK OR PROJECT OTHER THAN THE SPECIFIED PROJECT FOR WHICH THEY HAVE BEEN PREPARED WITHOUT THE WRITTEN CONSENT OF ONETENTEN HOMES.THE PLANS FURNISHED HEREIN WERE PREPARED UPON REQUEST BY DRAFTSPERSONS WHO ARE NOT REGISTERED ARCHITECTS OR ENGINEERS. ONETENTEN HOMES ASSUMES NO RESPONSIBILITY FOR STRUCTURAL OR DIMENSIONAL ERRORS OR OMISSIONS.THE CONTRACTOR AND/OR OWNER MUST VERIFY AND CHECKALL NOTES DETAILS, ELEVATIONS, SECTIONS AND FLOOR PLANS AND NOTIFY ONETENTEN HOMES OF ANY ERRORS OR OMISSIONS PRIOR TO THE START OF CONSTRUCTION. NO WARRANTIES ARE EXPRESSED OR IMPLIED INCLUDING COMPLIANCE OF THIS PLAN WITH APPLICABLE BUILDING CODE REQUIREMENTS. THE SELECTION AND APPLICATION OF CORRECT STRUCTURAL MATERIALS IS THE RESPONSIBILITY OF THE BUILDER, THE OWNER OR THE USER OF THESE PLANS.DATESQUARE FEETPROJECTSHEETUPPER:MAIN:LOWER:RELEASEDREV. 1REV. 2REV. 3REV. 4REV. 5PLATE HEIGHTSUPPER:MAIN:POUR:P.O. BOX 3915411 LAKERS LANE, SUITE 204NISSWA, MN 56468PH (612) 327-7582NORTHHOUSE-RD.COMBRAINERD LAKESTWIN CITIES3000 COUNTY ROAD 42 WEST, SUITE 202 BURNSVILLE, MN 55337PH (952)-953-4000ONETENTENHOMES.COMUNSPECIFIED HEADERS TO BE 2-2x10 W/ 2 TRIMMERS10" MIN. STAIR TREAD DEPTH & 7 3/4" MAX STAIR RISER HEIGHTALL ANGLES ARE 45 DEGREES UNLESS NOTED OTHERWISEALL EXTERIOR DIMENSIONS ARE TO OUTSIDE OF SHEATHING, CONCRETE OR FOUNDATION INSULATIONTOTAL:TOTAL:4/13/2020 4:46:14 PMSPEC HOMEL31, B4 - KNOB HILL5710 UPPER 179TH STREET WESTLAKEVILLE, MN 55024A-502OTT1254.13.20 CB110610847664.10.20 CB8'-1 1/8"9'-1 1/8"8'-4"PAYTON XL295629561/2" = 1'-0"A-5021TYP. WALKOUT SECTION1/2" = 1'-0"A-5022TYP. HOUSE/STOOP WALL1/2" = 1'-0"A-5023TYP. HOUSE/GARAGE WALL3/8" = 1'-0"A-5024METHOD PFH - PORTAL FRAME WITH HOLD-DOWNS1/2" = 1'-0"A-5025BEARING WALL SECTION1/2" = 1'-0"A-5026TYP. LOOKOUT SECTION Upper Level Member Name Results Current Solution Comments Bedroom #2 Window Passed 2 piece(s) 2 x 10 Spruce-Pine-Fir No. 1 / No. 2 Bedroom #3 Window Passed 2 piece(s) 2 x 10 Spruce-Pine-Fir No. 1 / No. 2 Closet Window Passed 2 piece(s) 2 x 10 Spruce-Pine-Fir No. 1 / No. 2 Stair Landing Window Passed 2 piece(s) 2 x 10 Spruce-Pine-Fir No. 1 / No. 2 Main Level Member Name Results Current Solution Comments Kitchen Window Passed 2 piece(s) 2 x 10 Spruce-Pine-Fir No. 1 / No. 2 Dining Room Patio Door Passed 3 piece(s) 2 x 10 Spruce-Pine-Fir No. 1 / No. 2 Great Room Window Passed 2 piece(s) 2 x 10 Spruce-Pine-Fir No. 1 / No. 2 Office Window Passed 2 piece(s) 2 x 10 Spruce-Pine-Fir No. 1 / No. 2 Drop Front Porch (H)Passed 2 piece(s) 2 x 10 Spruce-Pine-Fir No. 1 / No. 2 Flush Stairs (H)Passed 2 piece(s) 1 3/4" x 11 7/8" 1.55E TimberStrand® LSL Foyer Front Door Passed 2 piece(s) 1 3/4" x 9 1/2" 1.55E TimberStrand® LSL Garage 16' OHD Passed 2 piece(s) 1 3/4" x 11 7/8" 1.55E TimberStrand® LSL Garage 8' OHD Passed 2 piece(s) 2 x 12 Spruce-Pine-Fir No. 1 / No. 2 Mudroom Door Passed 2 piece(s) 2 x 10 Spruce-Pine-Fir No. 1 / No. 2 Flush Pantry (H)Passed 2 piece(s) 1 3/4" x 9 1/2" 1.55E TimberStrand® LSL Mudroom Kitchen Opening Passed 2 piece(s) 2 x 10 Spruce-Pine-Fir No. 1 / No. 2 Flush Foyer (H)Passed 2 piece(s) 1 3/4" x 11 7/8" 1.55E TimberStrand® LSL Flush Foyer (V)Passed 2 piece(s) 1 3/4" x 11 7/8" 1.55E TimberStrand® LSL Lower Level Member Name Results Current Solution Comments Bedroom #4 Window Passed 2 piece(s) 2 x 10 Spruce-Pine-Fir No. 1 / No. 2 Family Room Middle Window Passed 3 piece(s) 2 x 10 Spruce-Pine-Fir No. 1 / No. 2 Family Room End Window Passed 3 piece(s) 1 3/4" x 9 1/2" 2.0E Microllam® LVL Mechanical Room Door Passed 2 piece(s) 2 x 10 Spruce-Pine-Fir No. 1 / No. 2 Bathroom Door Passed 2 piece(s) 1 3/4" x 9 1/2" 1.55E TimberStrand® LSL Bedroom #4 Closet Door Passed 2 piece(s) 2 x 10 Spruce-Pine-Fir No. 1 / No. 2 5710 Upper 179th Street, Lakeville, MN JOB SUMMARY REPORT ForteWEB Software Operator Job Notes 5/27/2020 7:43:49 PM UTCJeffrey Doty, Design Supervisor Lyman Lumber Company (952) 470-4866 jeff_doty@lymanlumber.com ForteWEB v2.4 File Name: 5710 Upper 179th Street, Lakeville, MN Topaz - Payton XL 5710 Upper 179th Street, Lakeville, MN 5/27/2020; #24120 Page 1 / 25 Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (lbs)2288 @ 1 1/2"3825 (3.00")Passed (60%)--1.0 D + 1.0 S (All Spans) Shear (lbs)1439 @ 1' 1/4"2872 Passed (50%)1.15 1.0 D + 1.0 S (All Spans) Moment (Ft-lbs)2867 @ 2' 9"3946 Passed (73%)1.15 1.0 D + 1.0 S (All Spans) Live Load Defl. (in)0.032 @ 2' 9"0.175 Passed (L/999+)--1.0 D + 1.0 S (All Spans) Total Load Defl. (in)0.051 @ 2' 9"0.262 Passed (L/999+)--1.0 D + 1.0 S (All Spans) System : Wall Member Type : Header Building Use : Residential Building Code : IBC 2018 Design Methodology : ASD •Deflection criteria: LL (L/360) and TL (L/240). •Top Edge Bracing (Lu): Top compression edge must be braced at 5' 6" o/c based on loads applied, unless detailed otherwise. •Bottom Edge Bracing (Lu): Bottom compression edge must be braced at 5' 6" o/c based on loads applied, unless detailed otherwise. •Applicable calculations are based on NDS. Bearing Length Loads to Supports (lbs) Supports Total Available Required Dead Snow Total Accessories 1 - Trimmer - SPF 3.00"3.00"1.79"844 1444 2288 None 2 - Trimmer - SPF 3.00"3.00"1.79"844 1444 2288 None Dead Snow Vertical Loads Location (Side)Tributary Width (0.90)(1.15)Comments 0 - Self Weight (PLF)0 to 5' 6"N/A 7.0 -- 1 - Uniform (PSF)0 to 5' 6"15'20.0 35.0 Snow - Main Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/document-library. The product application, input design loads, dimensions and support information have been provided by NH; plan dated 4/13/2020. Weyerhaeuser Notes All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal. MEMBER REPORT PASSED Upper Level, Bedroom #2 Window 2 piece(s) 2 x 10 Spruce-Pine-Fir No. 1 / No. 2 ForteWEB Software Operator Job Notes 5/27/2020 7:43:49 PM UTCJeffrey Doty, Design Supervisor Lyman Lumber Company (952) 470-4866 jeff_doty@lymanlumber.com ForteWEB v2.4, Engine: V8.0.1.5, Data: V7.3.2.0 File Name: 5710 Upper 179th Street, Lakeville, MN Topaz - Payton XL 5710 Upper 179th Street, Lakeville, MN 5/27/2020; #24120 Page 2 / 25 Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (lbs)2288 @ 1 1/2"3825 (3.00")Passed (60%)--1.0 D + 1.0 S (All Spans) Shear (lbs)1439 @ 1' 1/4"2872 Passed (50%)1.15 1.0 D + 1.0 S (All Spans) Moment (Ft-lbs)2867 @ 2' 9"3946 Passed (73%)1.15 1.0 D + 1.0 S (All Spans) Live Load Defl. (in)0.032 @ 2' 9"0.175 Passed (L/999+)--1.0 D + 1.0 S (All Spans) Total Load Defl. (in)0.051 @ 2' 9"0.262 Passed (L/999+)--1.0 D + 1.0 S (All Spans) System : Wall Member Type : Header Building Use : Residential Building Code : IBC 2018 Design Methodology : ASD •Deflection criteria: LL (L/360) and TL (L/240). •Top Edge Bracing (Lu): Top compression edge must be braced at 5' 6" o/c based on loads applied, unless detailed otherwise. •Bottom Edge Bracing (Lu): Bottom compression edge must be braced at 5' 6" o/c based on loads applied, unless detailed otherwise. •Applicable calculations are based on NDS. Bearing Length Loads to Supports (lbs) Supports Total Available Required Dead Snow Total Accessories 1 - Trimmer - SPF 3.00"3.00"1.79"844 1444 2288 None 2 - Trimmer - SPF 3.00"3.00"1.79"844 1444 2288 None Dead Snow Vertical Loads Location (Side)Tributary Width (0.90)(1.15)Comments 0 - Self Weight (PLF)0 to 5' 6"N/A 7.0 -- 1 - Uniform (PSF)0 to 5' 6"15'20.0 35.0 Snow - Main Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/document-library. The product application, input design loads, dimensions and support information have been provided by NH; plan dated 4/13/2020. Weyerhaeuser Notes All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal. MEMBER REPORT PASSED Upper Level, Bedroom #3 Window 2 piece(s) 2 x 10 Spruce-Pine-Fir No. 1 / No. 2 ForteWEB Software Operator Job Notes 5/27/2020 7:43:49 PM UTCJeffrey Doty, Design Supervisor Lyman Lumber Company (952) 470-4866 jeff_doty@lymanlumber.com ForteWEB v2.4, Engine: V8.0.1.5, Data: V7.3.2.0 File Name: 5710 Upper 179th Street, Lakeville, MN Topaz - Payton XL 5710 Upper 179th Street, Lakeville, MN 5/27/2020; #24120 Page 3 / 25 Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (lbs)306 @ 0 1913 (1.50")Passed (16%)--1.0 D + 1.0 S (All Spans) Shear (lbs)62 @ 10 3/4"2872 Passed (2%)1.15 1.0 D + 1.0 S (All Spans) Moment (Ft-lbs)172 @ 1' 1 1/2"3946 Passed (4%)1.15 1.0 D + 1.0 S (All Spans) Live Load Defl. (in)0.000 @ 1' 1 1/2"0.075 Passed (L/999+)--1.0 D + 1.0 S (All Spans) Total Load Defl. (in)0.001 @ 1' 1 1/2"0.112 Passed (L/999+)--1.0 D + 1.0 S (All Spans) System : Wall Member Type : Header Building Use : Residential Building Code : IBC 2018 Design Methodology : ASD •Deflection criteria: LL (L/360) and TL (L/240). •Top Edge Bracing (Lu): Top compression edge must be braced at 2' 3" o/c based on loads applied, unless detailed otherwise. •Bottom Edge Bracing (Lu): Bottom compression edge must be braced at 2' 3" o/c based on loads applied, unless detailed otherwise. •Applicable calculations are based on NDS. Bearing Length Loads to Supports (lbs) Supports Total Available Required Dead Snow Total Accessories 1 - Trimmer - SPF 1.50"1.50"1.50"188 118 306 None 2 - Trimmer - SPF 1.50"1.50"1.50"188 118 306 None Dead Snow Vertical Loads Location (Side)Tributary Width (0.90)(1.15)Comments 0 - Self Weight (PLF)0 to 2' 3"N/A 7.0 -- 1 - Uniform (PSF)0 to 2' 3"3'20.0 35.0 Snow - Main 2 - Uniform (PLF)0 to 2' 3"N/A 100.0 -Wall - Gable Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/document-library. The product application, input design loads, dimensions and support information have been provided by NH; plan dated 4/13/2020. Weyerhaeuser Notes All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal. MEMBER REPORT PASSED Upper Level, Closet Window 2 piece(s) 2 x 10 Spruce-Pine-Fir No. 1 / No. 2 ForteWEB Software Operator Job Notes 5/27/2020 7:43:49 PM UTCJeffrey Doty, Design Supervisor Lyman Lumber Company (952) 470-4866 jeff_doty@lymanlumber.com ForteWEB v2.4, Engine: V8.0.1.5, Data: V7.3.2.0 File Name: 5710 Upper 179th Street, Lakeville, MN Topaz - Payton XL 5710 Upper 179th Street, Lakeville, MN 5/27/2020; #24120 Page 4 / 25 Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (lbs)1768 @ 0 1913 (1.50")Passed (92%)--1.0 D + 1.0 S (All Spans) Shear (lbs)1023 @ 10 3/4"2872 Passed (36%)1.15 1.0 D + 1.0 S (All Spans) Moment (Ft-lbs)1879 @ 2' 1 1/2"3946 Passed (48%)1.15 1.0 D + 1.0 S (All Spans) Live Load Defl. (in)0.014 @ 2' 1 1/2"0.142 Passed (L/999+)--1.0 D + 1.0 S (All Spans) Total Load Defl. (in)0.022 @ 2' 1 1/2"0.213 Passed (L/999+)--1.0 D + 1.0 S (All Spans) System : Wall Member Type : Header Building Use : Residential Building Code : IBC 2018 Design Methodology : ASD •Deflection criteria: LL (L/360) and TL (L/240). •Top Edge Bracing (Lu): Top compression edge must be braced at 4' 3" o/c based on loads applied, unless detailed otherwise. •Bottom Edge Bracing (Lu): Bottom compression edge must be braced at 4' 3" o/c based on loads applied, unless detailed otherwise. •Applicable calculations are based on NDS. Bearing Length Loads to Supports (lbs) Supports Total Available Required Dead Snow Total Accessories 1 - Trimmer - SPF 1.50"1.50"1.50"652 1116 1768 None 2 - Trimmer - SPF 1.50"1.50"1.50"652 1116 1768 None Dead Snow Vertical Loads Location (Side)Tributary Width (0.90)(1.15)Comments 0 - Self Weight (PLF)0 to 4' 3"N/A 7.0 -- 1 - Uniform (PSF)0 to 4' 3"15'20.0 35.0 Snow - Main Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/document-library. The product application, input design loads, dimensions and support information have been provided by NH; plan dated 4/13/2020. Weyerhaeuser Notes All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal. MEMBER REPORT PASSED Upper Level, Stair Landing Window 2 piece(s) 2 x 10 Spruce-Pine-Fir No. 1 / No. 2 ForteWEB Software Operator Job Notes 5/27/2020 7:43:49 PM UTCJeffrey Doty, Design Supervisor Lyman Lumber Company (952) 470-4866 jeff_doty@lymanlumber.com ForteWEB v2.4, Engine: V8.0.1.5, Data: V7.3.2.0 File Name: 5710 Upper 179th Street, Lakeville, MN Topaz - Payton XL 5710 Upper 179th Street, Lakeville, MN 5/27/2020; #24120 Page 5 / 25 Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (lbs)1143 @ 0 1913 (1.50")Passed (60%)--1.0 D + 1.0 L (All Spans) Shear (lbs)597 @ 10 3/4"2498 Passed (24%)1.00 1.0 D + 1.0 L (All Spans) Moment (Ft-lbs)1071 @ 1' 10 1/2"3431 Passed (31%)1.00 1.0 D + 1.0 L (All Spans) Live Load Defl. (in)0.006 @ 1' 10 1/2"0.125 Passed (L/999+)--1.0 D + 1.0 L (All Spans) Total Load Defl. (in)0.010 @ 1' 10 1/2"0.188 Passed (L/999+)--1.0 D + 1.0 L (All Spans) System : Wall Member Type : Header Building Use : Residential Building Code : IBC 2018 Design Methodology : ASD •Deflection criteria: LL (L/360) and TL (L/240). •Top Edge Bracing (Lu): Top compression edge must be braced at 3' 9" o/c based on loads applied, unless detailed otherwise. •Bottom Edge Bracing (Lu): Bottom compression edge must be braced at 3' 9" o/c based on loads applied, unless detailed otherwise. •Applicable calculations are based on NDS. Bearing Length Loads to Supports (lbs) Supports Total Available Required Dead Floor Live Total Accessories 1 - Trimmer - SPF 1.50"1.50"1.50"430 713 1143 None 2 - Trimmer - SPF 1.50"1.50"1.50"430 713 1143 None Dead Floor Live Vertical Loads Location (Side)Tributary Width (0.90)(1.00)Comments 0 - Self Weight (PLF)0 to 3' 9"N/A 7.0 -- 1 - Uniform (PSF)0 to 3' 9"9' 6"15.0 40.0 Floor - Upper Level 2 - Uniform (PSF)0 to 3' 9"1'80.0 -Wall - Upper Level Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/document-library. The product application, input design loads, dimensions and support information have been provided by NH; plan dated 4/13/2020. Weyerhaeuser Notes All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal. MEMBER REPORT PASSED Main Level, Kitchen Window 2 piece(s) 2 x 10 Spruce-Pine-Fir No. 1 / No. 2 ForteWEB Software Operator Job Notes 5/27/2020 7:43:49 PM UTCJeffrey Doty, Design Supervisor Lyman Lumber Company (952) 470-4866 jeff_doty@lymanlumber.com ForteWEB v2.4, Engine: V8.0.1.5, Data: V7.3.2.0 File Name: 5710 Upper 179th Street, Lakeville, MN Topaz - Payton XL 5710 Upper 179th Street, Lakeville, MN 5/27/2020; #24120 Page 6 / 25 Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (lbs)4064 @ 1 1/2"5738 (3.00")Passed (71%)--1.0 D + 0.75 L + 0.75 S (All Spans) Shear (lbs)2872 @ 1' 1/4"4308 Passed (67%)1.15 1.0 D + 0.75 L + 0.75 S (All Spans) Moment (Ft-lbs)5146 @ 1' 11"5919 Passed (87%)1.15 1.0 D + 0.75 L + 0.75 S (All Spans) Live Load Defl. (in)0.045 @ 3' 1"0.208 Passed (L/999+)--1.0 D + 0.75 L + 0.75 S (All Spans) Total Load Defl. (in)0.081 @ 3' 1 1/16"0.313 Passed (L/922)--1.0 D + 0.75 L + 0.75 S (All Spans) System : Wall Member Type : Header Building Use : Residential Building Code : IBC 2018 Design Methodology : ASD •Deflection criteria: LL (L/360) and TL (L/240). •Top Edge Bracing (Lu): Top compression edge must be braced at 6' 6" o/c based on loads applied, unless detailed otherwise. •Bottom Edge Bracing (Lu): Bottom compression edge must be braced at 6' 6" o/c based on loads applied, unless detailed otherwise. •Applicable calculations are based on NDS. Bearing Length Loads to Supports (lbs) Supports Total Available Required Dead Floor Live Snow Total Accessories 1 - Trimmer - SPF 3.00"3.00"2.12"1809 1105 1901 4815 None 2 - Trimmer - SPF 3.00"3.00"1.50"1028 1105 549 2682 None Dead Floor Live Snow Vertical Loads Location (Side)Tributary Width (0.90)(1.00)(1.15)Comments 0 - Self Weight (PLF)0 to 6' 6"N/A 10.6 ---- 1 - Uniform (PSF)0 to 6' 6"8' 6"15.0 40.0 -Floor - Upper Level 2 - Uniform (PSF)0 to 6' 6"1'80.0 --Wall - Upper Level 3 - Uniform (PSF)0 to 1' 11"15'20.0 -35.0 Snow - Main 4 - Point (lb)1' 11"N/A 844 -1444 Linked from: Loft Window, Support 1 Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/document-library. The product application, input design loads, dimensions and support information have been provided by NH; plan dated 4/13/2020. Weyerhaeuser Notes All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal. MEMBER REPORT PASSED Main Level, Dining Room Patio Door 3 piece(s) 2 x 10 Spruce-Pine-Fir No. 1 / No. 2 ForteWEB Software Operator Job Notes 5/27/2020 7:43:49 PM UTCJeffrey Doty, Design Supervisor Lyman Lumber Company (952) 470-4866 jeff_doty@lymanlumber.com ForteWEB v2.4, Engine: V8.0.1.5, Data: V7.3.2.0 File Name: 5710 Upper 179th Street, Lakeville, MN Topaz - Payton XL 5710 Upper 179th Street, Lakeville, MN 5/27/2020; #24120 Page 7 / 25 Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (lbs)5786 @ 3' 9 3/4"5738 (4.50")Passed (101%)--1.0 D + 0.75 L + 0.75 S (Adj Spans) Shear (lbs)2430 @ 6' 8 3/4"2872 Passed (85%)1.15 1.0 D + 1.0 S (Alt Spans) Moment (Ft-lbs)-2244 @ 3' 9 3/4"3946 Passed (57%)1.15 1.0 D + 0.75 L + 0.75 S (Adj Spans) Live Load Defl. (in)0.008 @ 5' 9 3/4"0.129 Passed (L/999+)--1.0 D + 0.75 L + 0.75 S (Alt Spans) Total Load Defl. (in)0.012 @ 5' 10"0.194 Passed (L/999+)--1.0 D + 0.75 L + 0.75 S (Alt Spans) System : Wall Member Type : Header Building Use : Residential Building Code : IBC 2018 Design Methodology : ASD •Deflection criteria: LL (L/360) and TL (L/240). •Top Edge Bracing (Lu): Top compression edge must be braced at 11' 8" o/c based on loads applied, unless detailed otherwise. •Bottom Edge Bracing (Lu): Bottom compression edge must be braced at 11' 8" o/c based on loads applied, unless detailed otherwise. •Applicable calculations are based on NDS. Bearing Length Loads to Supports (lbs) Supports Total Available Required Dead Floor Live Snow Total Accessories 1 - Trimmer - SPF 1.50"1.50"1.50"728 584/-67 787 2099/- 67 None 2 - Trimmer - SPF 4.50"4.50"4.54"2513 1566 2799 6878 None 3 - Trimmer - SPF 4.50"4.50"3.26"1783 1566 1604 4953 None 4 - Trimmer - SPF 3.00"3.00"2.05"1107 626/-67 1384 3117/- 67 None Dead Floor Live Snow Vertical Loads Location (Side)Tributary Width (0.90)(1.00)(1.15)Comments 0 - Self Weight (PLF)0 to 11' 7 1/2"N/A 7.0 ---- 1 - Uniform (PSF)0 to 11' 7 1/2"8' 6"15.0 40.0 -Floor - Upper Level 2 - Uniform (PSF)0 to 11' 7 1/2"1'80.0 --Wall - Upper Level 3 - Uniform (PSF)0 to 6' 6"15'20.0 -35.0 Snow - Main 4 - Point (lb)6' 6"N/A 844 -1444 Linked from: Bedroom # 2 Window, Support 1 5 - Point (lb)11' 6"N/A 844 -1444 Linked from: Bedroom # 2 Window, Support 2 Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/document-library. The product application, input design loads, dimensions and support information have been provided by NH; plan dated 4/13/2020. Weyerhaeuser Notes All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal. MEMBER REPORT PASSED Main Level, Great Room Window 2 piece(s) 2 x 10 Spruce-Pine-Fir No. 1 / No. 2 ForteWEB Software Operator Job Notes 5/27/2020 7:43:49 PM UTCJeffrey Doty, Design Supervisor Lyman Lumber Company (952) 470-4866 jeff_doty@lymanlumber.com ForteWEB v2.4, Engine: V8.0.1.5, Data: V7.3.2.0 File Name: 5710 Upper 179th Street, Lakeville, MN Topaz - Payton XL 5710 Upper 179th Street, Lakeville, MN 5/27/2020; #24120 Page 8 / 25 Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (lbs)2612 @ 1 1/2"3825 (3.00")Passed (68%)--1.0 D + 0.75 L + 0.75 S (All Spans) Shear (lbs)1484 @ 1' 1/4"2498 Passed (59%)1.00 1.0 D + 1.0 L (All Spans) Moment (Ft-lbs)2916 @ 3' 3"3431 Passed (85%)1.00 1.0 D + 1.0 L (All Spans) Live Load Defl. (in)0.040 @ 3' 3"0.208 Passed (L/999+)--1.0 D + 0.75 L + 0.75 S (All Spans) Total Load Defl. (in)0.081 @ 3' 3"0.313 Passed (L/924)--1.0 D + 0.75 L + 0.75 S (All Spans) System : Wall Member Type : Header Building Use : Residential Building Code : IBC 2018 Design Methodology : ASD •Deflection criteria: LL (L/360) and TL (L/240). •Top Edge Bracing (Lu): Top compression edge must be braced at 6' 6" o/c based on loads applied, unless detailed otherwise. •Bottom Edge Bracing (Lu): Bottom compression edge must be braced at 6' 6" o/c based on loads applied, unless detailed otherwise. •Applicable calculations are based on NDS. Bearing Length Loads to Supports (lbs) Supports Total Available Required Dead Floor Live Snow Total Accessories 1 - Trimmer - SPF 3.00"3.00"2.05"1398 910 709 3017 None 2 - Trimmer - SPF 3.00"3.00"2.05"1398 910 709 3017 None Dead Floor Live Snow Vertical Loads Location (Side)Tributary Width (0.90)(1.00)(1.15)Comments 0 - Self Weight (PLF)0 to 6' 6"N/A 7.0 ---- 1 - Uniform (PSF)0 to 6' 6"7'15.0 40.0 -Floor - Upper Level 2 - Uniform (PSF)0 to 6' 6"1'80.0 --Wall - Upper Level 3 - Uniform (PSF)0 to 6' 6"3'20.0 -35.0 Snow - Porch 4 - Point (lb)9"N/A 459 -289 Bedroom # 3 Window 5 - Point (lb)5' 9"N/A 459 -289 Bedroom # 3 Window 6 - Uniform (PSF)0 to 9"3'20.0 -35.0 Snow - Main 7 - Uniform (PSF)5' 9" to 6' 6"3'20.0 -35.0 Snow - Main 8 - Uniform (PSF)0 to 9"1'100.0 --Wall - Gable 9 - Uniform (PSF)5' 9" to 6' 6"1'100.0 --Wall - Gable Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/document-library. The product application, input design loads, dimensions and support information have been provided by NH; plan dated 4/13/2020. Weyerhaeuser Notes All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal. MEMBER REPORT PASSED Main Level, Office Window 2 piece(s) 2 x 10 Spruce-Pine-Fir No. 1 / No. 2 ForteWEB Software Operator Job Notes 5/27/2020 7:43:49 PM UTCJeffrey Doty, Design Supervisor Lyman Lumber Company (952) 470-4866 jeff_doty@lymanlumber.com ForteWEB v2.4, Engine: V8.0.1.5, Data: V7.3.2.0 File Name: 5710 Upper 179th Street, Lakeville, MN Topaz - Payton XL 5710 Upper 179th Street, Lakeville, MN 5/27/2020; #24120 Page 9 / 25 Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (lbs)3338 @ 7' 7"7013 (5.50")Passed (48%)--1.0 D + 1.0 S (Adj Spans) Shear (lbs)1561 @ 8' 7"2872 Passed (54%)1.15 1.0 D + 1.0 S (Adj Spans) Moment (Ft-lbs)-3305 @ 7' 7"3946 Passed (84%)1.15 1.0 D + 1.0 S (Adj Spans) Live Load Defl. (in)0.122 @ 13' 6 1/2"0.367 Passed (L/999+)--1.0 D + 1.0 S (Alt Spans) Total Load Defl. (in)0.189 @ 13' 6 7/8"0.550 Passed (L/700)--1.0 D + 1.0 S (Alt Spans) System : Roof Member Type : Drop Beam Building Use : Residential Building Code : IBC 2018 Design Methodology : ASD Member Pitch : 0/12 •Deflection criteria: LL (L/360) and TL (L/240). •Overhang deflection criteria: LL (2L/360) and TL (2L/240). •Top Edge Bracing (Lu): Top compression edge must be braced at 12' 1" o/c based on loads applied, unless detailed otherwise. •Bottom Edge Bracing (Lu): Bottom compression edge must be braced at 8' 11" o/c based on loads applied, unless detailed otherwise. •Applicable calculations are based on NDS. • Blocking Panels are assumed to carry no loads applied directly above them and the full load is applied to the member being designed. Bearing Length Loads to Supports (lbs) Supports Total Available Required Dead Snow Total Accessories 1 - Stud wall - SPF 3.00"3.00"1.50"245 506 751 Blocking 2 - Stud wall - SPF 5.50"5.50"2.62"1264 2074 3338 Blocking 3 - Stud wall - SPF 5.50"5.50"1.50"587 982 1569 Blocking Dead Snow Vertical Loads Location (Side)Tributary Width (0.90)(1.15)Comments 0 - Self Weight (PLF)0 to 19' 7"N/A 7.0 -- 1 - Uniform (PSF)0 to 19' 7" (Front)5'20.0 35.0 Snow - Porch Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/document-library. The product application, input design loads, dimensions and support information have been provided by NH; plan dated 4/13/2020. Weyerhaeuser Notes All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal. MEMBER REPORT PASSED Main Level, Drop Front Porch (H) 2 piece(s) 2 x 10 Spruce-Pine-Fir No. 1 / No. 2 ForteWEB Software Operator Job Notes 5/27/2020 7:43:49 PM UTCJeffrey Doty, Design Supervisor Lyman Lumber Company (952) 470-4866 jeff_doty@lymanlumber.com ForteWEB v2.4, Engine: V8.0.1.5, Data: V7.3.2.0 File Name: 5710 Upper 179th Street, Lakeville, MN Topaz - Payton XL 5710 Upper 179th Street, Lakeville, MN 5/27/2020; #24120 Page 10 / 25 Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (lbs)5631 @ 11' 2"8181 (5.50")Passed (69%)--1.0 D + 1.0 L (All Spans) Shear (lbs)3777 @ 10' 5/8"8590 Passed (44%)1.00 1.0 D + 1.0 L (All Spans) Moment (Ft-lbs)10448 @ 6' 1 1/4"15953 Passed (65%)1.00 1.0 D + 1.0 L (All Spans) Live Load Defl. (in)0.227 @ 5' 10"0.271 Passed (L/573)--1.0 D + 1.0 L (All Spans) Total Load Defl. (in)0.328 @ 5' 10 1/4"0.542 Passed (L/396)--1.0 D + 1.0 L (All Spans) System : Floor Member Type : Flush Beam Building Use : Residential Building Code : IBC 2018 Design Methodology : ASD •Deflection criteria: LL (L/480) and TL (L/240). •Top Edge Bracing (Lu): Top compression edge must be braced at 10' o/c based on loads applied, unless detailed otherwise. •Bottom Edge Bracing (Lu): Bottom compression edge must be braced at 11' 6" o/c based on loads applied, unless detailed otherwise. • Blocking Panels are assumed to carry no loads applied directly above them and the full load is applied to the member being designed. Bearing Length Loads to Supports (lbs) Supports Total Available Required Dead Floor Live Snow Total Accessories 1 - Stud wall - SPF 5.50"5.50"2.32"1033 2419 66 3518 Blocking 2 - Stud wall - SPF 5.50"5.50"3.79"2153 3478 1013 6644 Blocking Dead Floor Live Snow Vertical Loads Location (Side)Tributary Width (0.90)(1.00)(1.15)Comments 0 - Self Weight (PLF)0 to 11' 6"N/A 13.0 ---- 1 - Uniform (PSF)0 to 4' (Front)8' 6"15.0 40.0 -Floor - Upper Level 2 - Uniform (PSF)4' to 10' 6" (Front)13'15.0 40.0 -Floor - Upper Level 3 - Point (lb)10' 6" (Front)N/A 1049 597 1079 Linked from: Flush Foyer (V), Support 2 4 - Uniform (PSF)10' 6" to 11' 6" (Front)14'15.0 40.0 -Floor - Upper Level Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/document-library. The product application, input design loads, dimensions and support information have been provided by NH; plan dated 4/13/2020. Weyerhaeuser Notes All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal. MEMBER REPORT PASSED Main Level, Flush Stairs (H) 2 piece(s) 1 3/4" x 11 7/8" 1.55E TimberStrand® LSL ForteWEB Software Operator Job Notes 5/27/2020 7:43:49 PM UTCJeffrey Doty, Design Supervisor Lyman Lumber Company (952) 470-4866 jeff_doty@lymanlumber.com ForteWEB v2.4, Engine: V8.0.1.5, Data: V7.3.2.0 File Name: 5710 Upper 179th Street, Lakeville, MN Topaz - Payton XL 5710 Upper 179th Street, Lakeville, MN 5/27/2020; #24120 Page 11 / 25 Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (lbs)10340 @ 5' 10 1/2"11419 (4.50")Passed (91%)--1.0 D + 1.0 S (All Spans) Shear (lbs)559 @ 1' 1/2"7902 Passed (7%)1.15 1.0 D + 1.0 S (All Spans) Moment (Ft-lbs)1179 @ 3'11985 Passed (10%)1.15 1.0 D + 1.0 S (All Spans) Live Load Defl. (in)0.014 @ 3'0.192 Passed (L/999+)--1.0 D + 1.0 S (All Spans) Total Load Defl. (in)0.023 @ 3'0.287 Passed (L/999+)--1.0 D + 1.0 S (All Spans) System : Wall Member Type : Header Building Use : Residential Building Code : IBC 2018 Design Methodology : ASD •Deflection criteria: LL (L/360) and TL (L/240). •Top Edge Bracing (Lu): Top compression edge must be braced at 6' 2" o/c based on loads applied, unless detailed otherwise. •Bottom Edge Bracing (Lu): Bottom compression edge must be braced at 6' 2" o/c based on loads applied, unless detailed otherwise. Bearing Length Loads to Supports (lbs) Supports Total Available Required Dead Floor Live Snow Total Accessories 1 - Trimmer - SPF 3.00"3.00"1.50"331 -525 856 None 2 - Trimmer - SPF 4.50"4.50"4.07"4564 931 5776 11271 None Dead Floor Live Snow Vertical Loads Location (Side)Tributary Width (0.90)(1.00)(1.15)Comments 0 - Self Weight (PLF)0 to 6' 1 1/2"N/A 10.4 ---- 1 - Uniform (PSF)0 to 6' 1 1/2"5'20.0 -35.0 Snow - Porch 2 - Point (lb)6' 1 1/2"N/A 4219 931 5229 Linked from: Flush Foyer (V), Support 1 Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/document-library. The product application, input design loads, dimensions and support information have been provided by NH; plan dated 4/13/2020. Weyerhaeuser Notes All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal. MEMBER REPORT PASSED Main Level, Foyer Front Door 2 piece(s) 1 3/4" x 9 1/2" 1.55E TimberStrand® LSL ForteWEB Software Operator Job Notes 5/27/2020 7:43:49 PM UTCJeffrey Doty, Design Supervisor Lyman Lumber Company (952) 470-4866 jeff_doty@lymanlumber.com ForteWEB v2.4, Engine: V8.0.1.5, Data: V7.3.2.0 File Name: 5710 Upper 179th Street, Lakeville, MN Topaz - Payton XL 5710 Upper 179th Street, Lakeville, MN 5/27/2020; #24120 Page 12 / 25 Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (lbs)2328 @ 1 1/2"7613 (3.00")Passed (31%)--1.0 D + 1.0 S (All Spans) Shear (lbs)1984 @ 1' 2 7/8"9878 Passed (20%)1.15 1.0 D + 1.0 S (All Spans) Moment (Ft-lbs)9460 @ 8' 4 1/2"18346 Passed (52%)1.15 1.0 D + 1.0 S (All Spans) Live Load Defl. (in)0.244 @ 8' 4 1/2"0.550 Passed (L/811)--1.0 D + 1.0 S (All Spans) Total Load Defl. (in)0.646 @ 8' 4 1/2"0.825 Passed (L/306)--1.0 D + 1.0 S (All Spans) System : Wall Member Type : Header Building Use : Residential Building Code : IBC 2018 Design Methodology : ASD •Deflection criteria: LL (L/360) and TL (L/240). •Top Edge Bracing (Lu): Top compression edge must be braced at 11' 9" o/c based on loads applied, unless detailed otherwise. •Bottom Edge Bracing (Lu): Bottom compression edge must be braced at 16' 9" o/c based on loads applied, unless detailed otherwise. Bearing Length Loads to Supports (lbs) Supports Total Available Required Dead Snow Total Accessories 1 - Trimmer - SPF 3.00"3.00"1.50"1449 879 2328 None 2 - Trimmer - SPF 3.00"3.00"1.50"1449 879 2328 None Dead Snow Vertical Loads Location (Side)Tributary Width (0.90)(1.15)Comments 0 - Self Weight (PLF)0 to 16' 9"N/A 13.0 -- 1 - Uniform (PSF)0 to 16' 9"3'20.0 35.0 Snow - Garage 2 - Uniform (PSF)0 to 16' 9"1'100.0 -Wall - Gable Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/document-library. The product application, input design loads, dimensions and support information have been provided by NH; plan dated 4/13/2020. Weyerhaeuser Notes All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal. MEMBER REPORT PASSED Main Level, Garage 16' OHD 2 piece(s) 1 3/4" x 11 7/8" 1.55E TimberStrand® LSL ForteWEB Software Operator Job Notes 5/27/2020 7:43:49 PM UTCJeffrey Doty, Design Supervisor Lyman Lumber Company (952) 470-4866 jeff_doty@lymanlumber.com ForteWEB v2.4, Engine: V8.0.1.5, Data: V7.3.2.0 File Name: 5710 Upper 179th Street, Lakeville, MN Topaz - Payton XL 5710 Upper 179th Street, Lakeville, MN 5/27/2020; #24120 Page 13 / 25 Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (lbs)1197 @ 1 1/2"3825 (3.00")Passed (31%)--1.0 D + 1.0 S (All Spans) Shear (lbs)872 @ 1' 2 1/4"3493 Passed (25%)1.15 1.0 D + 1.0 S (All Spans) Moment (Ft-lbs)2470 @ 4' 4 1/2"5306 Passed (47%)1.15 1.0 D + 1.0 S (All Spans) Live Load Defl. (in)0.025 @ 4' 4 1/2"0.283 Passed (L/999+)--1.0 D + 1.0 S (All Spans) Total Load Defl. (in)0.064 @ 4' 4 1/2"0.425 Passed (L/999+)--1.0 D + 1.0 S (All Spans) System : Wall Member Type : Header Building Use : Residential Building Code : IBC 2018 Design Methodology : ASD •Deflection criteria: LL (L/360) and TL (L/240). •Top Edge Bracing (Lu): Top compression edge must be braced at 8' 9" o/c based on loads applied, unless detailed otherwise. •Bottom Edge Bracing (Lu): Bottom compression edge must be braced at 8' 9" o/c based on loads applied, unless detailed otherwise. •Applicable calculations are based on NDS. Bearing Length Loads to Supports (lbs) Supports Total Available Required Dead Snow Total Accessories 1 - Trimmer - SPF 3.00"3.00"1.50"737 459 1196 None 2 - Trimmer - SPF 3.00"3.00"1.50"737 459 1196 None Dead Snow Vertical Loads Location (Side)Tributary Width (0.90)(1.15)Comments 0 - Self Weight (PLF)0 to 8' 9"N/A 8.6 -- 1 - Uniform (PSF)0 to 8' 9"3'20.0 35.0 Snow - Garage 2 - Uniform (PSF)0 to 8' 9"1'100.0 -Wall - Gable Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/document-library. The product application, input design loads, dimensions and support information have been provided by NH; plan dated 4/13/2020. Weyerhaeuser Notes All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal. MEMBER REPORT PASSED Main Level, Garage 8' OHD 2 piece(s) 2 x 12 Spruce-Pine-Fir No. 1 / No. 2 ForteWEB Software Operator Job Notes 5/27/2020 7:43:49 PM UTCJeffrey Doty, Design Supervisor Lyman Lumber Company (952) 470-4866 jeff_doty@lymanlumber.com ForteWEB v2.4, Engine: V8.0.1.5, Data: V7.3.2.0 File Name: 5710 Upper 179th Street, Lakeville, MN Topaz - Payton XL 5710 Upper 179th Street, Lakeville, MN 5/27/2020; #24120 Page 14 / 25 Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (lbs)1192 @ 0 1913 (1.50")Passed (62%)--1.0 D + 0.75 L + 0.75 S (All Spans) Shear (lbs)499 @ 10 3/4"2872 Passed (17%)1.15 1.0 D + 0.75 L + 0.75 S (All Spans) Moment (Ft-lbs)919 @ 1' 6 1/2"3946 Passed (23%)1.15 1.0 D + 0.75 L + 0.75 S (All Spans) Live Load Defl. (in)0.003 @ 1' 6 1/2"0.103 Passed (L/999+)--1.0 D + 0.75 L + 0.75 S (All Spans) Total Load Defl. (in)0.006 @ 1' 6 1/2"0.154 Passed (L/999+)--1.0 D + 0.75 L + 0.75 S (All Spans) System : Wall Member Type : Header Building Use : Residential Building Code : IBC 2018 Design Methodology : ASD •Deflection criteria: LL (L/360) and TL (L/240). •Top Edge Bracing (Lu): Top compression edge must be braced at 3' 1" o/c based on loads applied, unless detailed otherwise. •Bottom Edge Bracing (Lu): Bottom compression edge must be braced at 3' 1" o/c based on loads applied, unless detailed otherwise. •Applicable calculations are based on NDS. Bearing Length Loads to Supports (lbs) Supports Total Available Required Dead Floor Live Snow Total Accessories 1 - Trimmer - SPF 1.50"1.50"1.50"550 370 486 1406 None 2 - Trimmer - SPF 1.50"1.50"1.50"550 370 486 1406 None Dead Floor Live Snow Vertical Loads Location (Side)Tributary Width (0.90)(1.00)(1.15)Comments 0 - Self Weight (PLF)0 to 3' 1"N/A 7.0 ---- 1 - Uniform (PSF)0 to 3' 1"6'15.0 40.0 -Floor - Upper Level 2 - Uniform (PSF)0 to 3' 1"1'80.0 --Wall - Upper Level 3 - Uniform (PSF)0 to 3' 1"9'20.0 -35.0 Snow - Main Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/document-library. The product application, input design loads, dimensions and support information have been provided by NH; plan dated 4/13/2020. Weyerhaeuser Notes All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal. MEMBER REPORT PASSED Main Level, Mudroom Door 2 piece(s) 2 x 10 Spruce-Pine-Fir No. 1 / No. 2 ForteWEB Software Operator Job Notes 5/27/2020 7:43:49 PM UTCJeffrey Doty, Design Supervisor Lyman Lumber Company (952) 470-4866 jeff_doty@lymanlumber.com ForteWEB v2.4, Engine: V8.0.1.5, Data: V7.3.2.0 File Name: 5710 Upper 179th Street, Lakeville, MN Topaz - Payton XL 5710 Upper 179th Street, Lakeville, MN 5/27/2020; #24120 Page 15 / 25 Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (lbs)2902 @ 1 1/2"4463 (3.00")Passed (65%)--1.0 D + 1.0 L (All Spans) Shear (lbs)2146 @ 1' 1/2"6872 Passed (31%)1.00 1.0 D + 1.0 L (All Spans) Moment (Ft-lbs)5446 @ 4'10422 Passed (52%)1.00 1.0 D + 1.0 L (All Spans) Live Load Defl. (in)0.126 @ 4'0.194 Passed (L/736)--1.0 D + 1.0 L (All Spans) Total Load Defl. (in)0.176 @ 4'0.387 Passed (L/528)--1.0 D + 1.0 L (All Spans) System : Floor Member Type : Flush Beam Building Use : Residential Building Code : IBC 2018 Design Methodology : ASD •Deflection criteria: LL (L/480) and TL (L/240). •Top Edge Bracing (Lu): Top compression edge must be braced at 8' o/c based on loads applied, unless detailed otherwise. •Bottom Edge Bracing (Lu): Bottom compression edge must be braced at 8' o/c based on loads applied, unless detailed otherwise. • Blocking Panels are assumed to carry no loads applied directly above them and the full load is applied to the member being designed. Bearing Length Loads to Supports (lbs) Supports Total Available Required Dead Floor Live Total Accessories 1 - Stud wall - SPF 3.00"3.00"1.95"822 2080 2902 Blocking 2 - Stud wall - SPF 3.00"3.00"1.95"822 2080 2902 Blocking Dead Floor Live Vertical Loads Location (Side)Tributary Width (0.90)(1.00)Comments 0 - Self Weight (PLF)0 to 8'N/A 10.4 -- 1 - Uniform (PSF)0 to 8' (Front)13'15.0 40.0 Floor - Upper Level Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/document-library. The product application, input design loads, dimensions and support information have been provided by NH; plan dated 4/13/2020. Weyerhaeuser Notes All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal. MEMBER REPORT PASSED Main Level, Flush Pantry (H) 2 piece(s) 1 3/4" x 9 1/2" 1.55E TimberStrand® LSL ForteWEB Software Operator Job Notes 5/27/2020 7:43:49 PM UTCJeffrey Doty, Design Supervisor Lyman Lumber Company (952) 470-4866 jeff_doty@lymanlumber.com ForteWEB v2.4, Engine: V8.0.1.5, Data: V7.3.2.0 File Name: 5710 Upper 179th Street, Lakeville, MN Topaz - Payton XL 5710 Upper 179th Street, Lakeville, MN 5/27/2020; #24120 Page 16 / 25 Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (lbs)1501 @ 0 1913 (1.50")Passed (78%)--1.0 D + 1.0 L (All Spans) Shear (lbs)694 @ 10 3/4"2498 Passed (28%)1.00 1.0 D + 1.0 L (All Spans) Moment (Ft-lbs)1251 @ 1' 8"3431 Passed (36%)1.00 1.0 D + 1.0 L (All Spans) Live Load Defl. (in)0.007 @ 1' 8"0.111 Passed (L/999+)--1.0 D + 1.0 L (All Spans) Total Load Defl. (in)0.009 @ 1' 8"0.167 Passed (L/999+)--1.0 D + 1.0 L (All Spans) System : Wall Member Type : Header Building Use : Residential Building Code : IBC 2018 Design Methodology : ASD •Deflection criteria: LL (L/360) and TL (L/240). •Top Edge Bracing (Lu): Top compression edge must be braced at 3' 4" o/c based on loads applied, unless detailed otherwise. •Bottom Edge Bracing (Lu): Bottom compression edge must be braced at 3' 4" o/c based on loads applied, unless detailed otherwise. •Applicable calculations are based on NDS. Bearing Length Loads to Supports (lbs) Supports Total Available Required Dead Floor Live Total Accessories 1 - Trimmer - SPF 1.50"1.50"1.50"418 1083 1501 None 2 - Trimmer - SPF 1.50"1.50"1.50"418 1083 1501 None Dead Floor Live Vertical Loads Location (Side)Tributary Width (0.90)(1.00)Comments 0 - Self Weight (PLF)0 to 3' 4"N/A 7.0 -- 1 - Uniform (PSF)0 to 3' 4"16' 3"15.0 40.0 Floor - Upper Level Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/document-library. The product application, input design loads, dimensions and support information have been provided by NH; plan dated 4/13/2020. Weyerhaeuser Notes All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal. MEMBER REPORT PASSED Main Level, Mudroom Kitchen Opening 2 piece(s) 2 x 10 Spruce-Pine-Fir No. 1 / No. 2 ForteWEB Software Operator Job Notes 5/27/2020 7:43:49 PM UTCJeffrey Doty, Design Supervisor Lyman Lumber Company (952) 470-4866 jeff_doty@lymanlumber.com ForteWEB v2.4, Engine: V8.0.1.5, Data: V7.3.2.0 File Name: 5710 Upper 179th Street, Lakeville, MN Topaz - Payton XL 5710 Upper 179th Street, Lakeville, MN 5/27/2020; #24120 Page 17 / 25 Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (lbs)3317 @ 3 1/2"4725 (1.50")Passed (70%)--1.0 D + 1.0 S (All Spans) Shear (lbs)2287 @ 1' 3 3/8"9878 Passed (23%)1.15 1.0 D + 1.0 S (All Spans) Moment (Ft-lbs)5286 @ 3' 5 3/4"18346 Passed (29%)1.15 1.0 D + 1.0 S (All Spans) Live Load Defl. (in)0.038 @ 3' 5 3/4"0.159 Passed (L/999+)--1.0 D + 1.0 S (All Spans) Total Load Defl. (in)0.070 @ 3' 5 3/4"0.319 Passed (L/999+)--1.0 D + 1.0 S (All Spans) System : Floor Member Type : Flush Beam Building Use : Residential Building Code : IBC 2018 Design Methodology : ASD •Deflection criteria: LL (L/480) and TL (L/240). •Top Edge Bracing (Lu): Top compression edge must be braced at 6' 9" o/c based on loads applied, unless detailed otherwise. •Bottom Edge Bracing (Lu): Bottom compression edge must be braced at 6' 9" o/c based on loads applied, unless detailed otherwise. • At hanger supports, the Total Bearing dimension is equal to the width of the material that is supporting the hanger • ¹ See Connector grid below for additional information and/or requirements. Bearing Length Loads to Supports (lbs) Supports Total Available Required Dead Floor Live Snow Total Accessories 1 - Hanger on 11 7/8" LSL beam 3.50"Hanger¹1.50"1668 626 1948 4242 See note ¹ 2 - Trimmer - SPF 5.50"5.50"1.50"1692 634 1972 4298 None Connector: Simpson Strong-Tie Support Model Seat Length Top Fasteners Face Fasteners Member Fasteners Accessories 1 - Face Mount Hanger HHUS410 3.00"N/A 30-10d 10-10d Dead Floor Live Snow Vertical Loads Location (Side)Tributary Width (0.90)(1.00)(1.15)Comments 0 - Self Weight (PLF)3 1/2" to 7'N/A 13.0 ---- 1 - Uniform (PSF)0 to 7' (Front)4' 6"15.0 40.0 -Floor - Upper Level 2 - Uniform (PLF)0 to 7' (Front)N/A 80.0 --Wall - Upper Level 3 - Uniform (PSF)0 to 7' (Front)1'20.0 -35.0 Snow - Porch 4 - Uniform (PSF)0 to 7' (Front)15'20.0 -35.0 Snow - Main Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/document-library. The product application, input design loads, dimensions and support information have been provided by NH; plan dated 4/13/2020. Weyerhaeuser Notes All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal. MEMBER REPORT PASSED Main Level, Flush Foyer (H) 2 piece(s) 1 3/4" x 11 7/8" 1.55E TimberStrand® LSL ForteWEB Software Operator Job Notes 5/27/2020 7:43:49 PM UTCJeffrey Doty, Design Supervisor Lyman Lumber Company (952) 470-4866 jeff_doty@lymanlumber.com ForteWEB v2.4, Engine: V8.0.1.5, Data: V7.3.2.0 File Name: 5710 Upper 179th Street, Lakeville, MN Topaz - Payton XL 5710 Upper 179th Street, Lakeville, MN 5/27/2020; #24120 Page 18 / 25 Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (lbs)9447 @ 1' 2 3/4"13956 (5.50")Passed (68%)--1.0 D + 1.0 S (All Spans) Shear (lbs)7904 @ 2' 5 3/8"9878 Passed (80%)1.15 1.0 D + 1.0 S (All Spans) Moment (Ft-lbs)17692 @ 3' 6"18346 Passed (96%)1.15 1.0 D + 1.0 S (Alt Spans) Live Load Defl. (in)0.251 @ 6' 2 7/8"0.287 Passed (L/550)--1.0 D + 1.0 S (Alt Spans) Total Load Defl. (in)0.459 @ 6' 3 5/16"0.574 Passed (L/300)--1.0 D + 1.0 S (Alt Spans) System : Floor Member Type : Flush Beam Building Use : Residential Building Code : IBC 2018 Design Methodology : ASD •Deflection criteria: LL (L/480) and TL (L/240). •Overhang deflection criteria: LL (2L/480) and TL (2L/240). •Top Edge Bracing (Lu): Top compression edge must be braced at 2' 7" o/c based on loads applied, unless detailed otherwise. •Bottom Edge Bracing (Lu): Bottom compression edge must be braced at 12' 9" o/c based on loads applied, unless detailed otherwise. • Blocking Panels are assumed to carry no loads applied directly above them and the full load is applied to the member being designed. • At hanger supports, the Total Bearing dimension is equal to the width of the material that is supporting the hanger • ¹ See Connector grid below for additional information and/or requirements. Bearing Length Loads to Supports (lbs) Supports Total Available Required Dead Floor Live Snow Total Accessories 1 - Column - SPF 5.50"5.50"3.72"4219 931 5229 10379 Blocking 2 - Hanger on 11 7/8" LSL beam 3.50"Hanger¹1.50"1049 597 1079 2725 See note ¹ Connector: Simpson Strong-Tie Support Model Seat Length Top Fasteners Face Fasteners Member Fasteners Accessories 2 - Face Mount Hanger HHUS410 3.00"N/A 30-10d 10-10d Dead Floor Live Snow Vertical Loads Location (Side)Tributary Width (0.90)(1.00)(1.15)Comments 0 - Self Weight (PLF)0 to 12' 8 1/2"N/A 13.0 ---- 1 - Point (lb)3' 6" (Front)N/A 1668 626 1948 Linked from: Flush Foyer (H), Support 1 2 - Uniform (PSF)0 to 3' 6" (Front)1'15.0 40.0 -Floor - Upper Level 3 - Uniform (PSF)3' 6" to 13' (Front)2'15.0 40.0 -Floor - Upper Level 4 - Uniform (PLF)0 to 3' 6" (Front)N/A 80.0 --Wall - Upper Level 5 - Uniform (PSF)0 to 3' 6" (Front)8' 6"20.0 -35.0 Snow - Main 6 - Uniform (PSF)0 to 3' 6" (Front)1'20.0 -35.0 Snow - Porch 7 - Point (lb)3' 6" (Front)N/A 2152 -3185 Linked from: GT3, Support 2 Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/document-library. The product application, input design loads, dimensions and support information have been provided by NH; plan dated 4/13/2020. Weyerhaeuser Notes All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal. MEMBER REPORT PASSED Main Level, Flush Foyer (V) 2 piece(s) 1 3/4" x 11 7/8" 1.55E TimberStrand® LSL ForteWEB Software Operator Job Notes 5/27/2020 7:43:49 PM UTCJeffrey Doty, Design Supervisor Lyman Lumber Company (952) 470-4866 jeff_doty@lymanlumber.com ForteWEB v2.4, Engine: V8.0.1.5, Data: V7.3.2.0 File Name: 5710 Upper 179th Street, Lakeville, MN Topaz - Payton XL 5710 Upper 179th Street, Lakeville, MN 5/27/2020; #24120 Page 19 / 25 Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (lbs)3147 @ 1 1/2"3825 (3.00")Passed (82%)--1.0 D + 1.0 L (All Spans) Shear (lbs)1993 @ 1' 1/4"2498 Passed (80%)1.00 1.0 D + 1.0 L (All Spans) Moment (Ft-lbs)2986 @ 2' 9"3431 Passed (87%)1.00 1.0 D + 1.0 L (All Spans) Live Load Defl. (in)0.034 @ 2' 9"0.175 Passed (L/999+)--1.0 D + 1.0 L (All Spans) Total Load Defl. (in)0.057 @ 2' 9"0.262 Passed (L/999+)--1.0 D + 1.0 L (All Spans) System : Wall Member Type : Header Building Use : Residential Building Code : IBC 2018 Design Methodology : ASD •Deflection criteria: LL (L/360) and TL (L/240). •Top Edge Bracing (Lu): Top compression edge must be braced at 5' 6" o/c based on loads applied, unless detailed otherwise. •Bottom Edge Bracing (Lu): Bottom compression edge must be braced at 5' 6" o/c based on loads applied, unless detailed otherwise. •Applicable calculations are based on NDS. Bearing Length Loads to Supports (lbs) Supports Total Available Required Dead Floor Live Total Accessories 1 - Trimmer - SPF 3.00"3.00"2.47"1229 1918 3147 None 2 - Trimmer - SPF 3.00"3.00"2.47"1229 1918 3147 None Dead Floor Live Vertical Loads Location (Side)Tributary Width (0.90)(1.00)Comments 0 - Self Weight (PLF)0 to 5' 6"N/A 7.0 -- 1 - Uniform (PSF)0 to 5' 6"7' 6"15.0 40.0 Floor - Main Level 2 - Uniform (PSF)0 to 5' 6"1'90.0 -Wall - Main Level 3 - Uniform (PSF)0 to 1'9' 6"15.0 40.0 Floor - Upper Level 4 - Uniform (PSF)4' 6" to 5' 6"9' 6"15.0 40.0 Floor - Upper Level 5 - Uniform (PSF)0 to 1'1'80.0 -Wall - Upper Level 6 - Uniform (PSF)4' 6" to 5' 6"1'80.0 -Wall - Upper Level 7 - Point (lb)1'N/A 430 713 Linked from: Kitchen Window, Support 1 8 - Point (lb)4' 6"N/A 430 713 Linked from: Kitchen Window, Support 2 Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/document-library. The product application, input design loads, dimensions and support information have been provided by NH; plan dated 4/13/2020. Weyerhaeuser Notes All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal. MEMBER REPORT PASSED Lower Level, Bedroom #4 Window 2 piece(s) 2 x 10 Spruce-Pine-Fir No. 1 / No. 2 ForteWEB Software Operator Job Notes 5/27/2020 7:43:49 PM UTCJeffrey Doty, Design Supervisor Lyman Lumber Company (952) 470-4866 jeff_doty@lymanlumber.com ForteWEB v2.4, Engine: V8.0.1.5, Data: V7.3.2.0 File Name: 5710 Upper 179th Street, Lakeville, MN Topaz - Payton XL 5710 Upper 179th Street, Lakeville, MN 5/27/2020; #24120 Page 20 / 25 Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (lbs)2449 @ 1 1/2"5738 (3.00")Passed (43%)--1.0 D + 1.0 L (All Spans) Shear (lbs)1540 @ 1' 1/4"3746 Passed (41%)1.00 1.0 D + 1.0 L (All Spans) Moment (Ft-lbs)3068 @ 2' 9"5147 Passed (60%)1.00 1.0 D + 1.0 L (All Spans) Live Load Defl. (in)0.025 @ 2' 9"0.175 Passed (L/999+)--1.0 D + 1.0 L (All Spans) Total Load Defl. (in)0.037 @ 2' 9"0.262 Passed (L/999+)--1.0 D + 1.0 L (All Spans) System : Wall Member Type : Header Building Use : Residential Building Code : IBC 2018 Design Methodology : ASD •Deflection criteria: LL (L/360) and TL (L/240). •Top Edge Bracing (Lu): Top compression edge must be braced at 5' 6" o/c based on loads applied, unless detailed otherwise. •Bottom Edge Bracing (Lu): Bottom compression edge must be braced at 5' 6" o/c based on loads applied, unless detailed otherwise. •Applicable calculations are based on NDS. Bearing Length Loads to Supports (lbs) Supports Total Available Required Dead Floor Live Total Accessories 1 - Trimmer - SPF 3.00"3.00"1.50"799 1650 2449 None 2 - Trimmer - SPF 3.00"3.00"1.50"799 1650 2449 None Dead Floor Live Vertical Loads Location (Side)Tributary Width (0.90)(1.00)Comments 0 - Self Weight (PLF)0 to 5' 6"N/A 10.6 -- 1 - Uniform (PSF)0 to 5' 6"8'15.0 40.0 Floor - Main Level 2 - Uniform (PSF)0 to 5' 6"1'90.0 -Wall - Main Level 3 - Uniform (PSF)0 to 5' 6"7'10.0 40.0 Floor - Deck Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/document-library. The product application, input design loads, dimensions and support information have been provided by NH; plan dated 4/13/2020. Weyerhaeuser Notes All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal. MEMBER REPORT PASSED Lower Level, Family Room Middle Window 3 piece(s) 2 x 10 Spruce-Pine-Fir No. 1 / No. 2 ForteWEB Software Operator Job Notes 5/27/2020 7:43:49 PM UTCJeffrey Doty, Design Supervisor Lyman Lumber Company (952) 470-4866 jeff_doty@lymanlumber.com ForteWEB v2.4, Engine: V8.0.1.5, Data: V7.3.2.0 File Name: 5710 Upper 179th Street, Lakeville, MN Topaz - Payton XL 5710 Upper 179th Street, Lakeville, MN 5/27/2020; #24120 Page 21 / 25 Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (lbs)8754 @ 1 1/2"11419 (3.00")Passed (77%)--1.0 D + 0.75 L + 0.75 S (All Spans) Shear (lbs)6951 @ 1' 1/2"9476 Passed (73%)1.00 1.0 D + 1.0 L (All Spans) Moment (Ft-lbs)16160 @ 4' 1 7/8"17662 Passed (91%)1.00 1.0 D + 1.0 L (All Spans) Live Load Defl. (in)0.200 @ 4' 2 1/2"0.275 Passed (L/496)--1.0 D + 0.75 L + 0.75 S (All Spans) Total Load Defl. (in)0.343 @ 4' 2 7/16"0.412 Passed (L/288)--1.0 D + 0.75 L + 0.75 S (All Spans) System : Wall Member Type : Header Building Use : Residential Building Code : IBC 2018 Design Methodology : ASD •Deflection criteria: LL (L/360) and TL (L/240). •Top Edge Bracing (Lu): Top compression edge must be braced at 8' 6" o/c based on loads applied, unless detailed otherwise. •Bottom Edge Bracing (Lu): Bottom compression edge must be braced at 8' 6" o/c based on loads applied, unless detailed otherwise. Bearing Length Loads to Supports (lbs) Supports Total Available Required Dead Floor Live Snow Total Accessories 1 - Trimmer - SPF 3.00"3.00"2.30"3663 4248 2540 10451 None 2 - Trimmer - SPF 3.00"3.00"2.03"3201 4154 1863 9218 None Dead Floor Live Snow Vertical Loads Location (Side)Tributary Width (0.90)(1.00)(1.15)Comments 0 - Self Weight (PLF)0 to 8' 6"N/A 14.5 ---- 1 - Uniform (PSF)0 to 8' 6"8' 6"15.0 40.0 -Floor - Main Level 2 - Uniform (PSF)0 to 8' 6"1'90.0 --Wall - Main Level 3 - Uniform (PSF)0 to 8' 6"7'10.0 40.0 -Floor - Deck 4 - Point (lb)2' 3"N/A 2513 1566 2799 Linked from: Great Room Window, Support 2 5 - Point (lb)6'N/A 1783 1566 1604 Linked from: Great Room Window, Support 3 Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/document-library. The product application, input design loads, dimensions and support information have been provided by NH; plan dated 4/13/2020. Weyerhaeuser Notes All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal. MEMBER REPORT PASSED Lower Level, Family Room End Window 3 piece(s) 1 3/4" x 9 1/2" 2.0E Microllam® LVL ForteWEB Software Operator Job Notes 5/27/2020 7:43:49 PM UTCJeffrey Doty, Design Supervisor Lyman Lumber Company (952) 470-4866 jeff_doty@lymanlumber.com ForteWEB v2.4, Engine: V8.0.1.5, Data: V7.3.2.0 File Name: 5710 Upper 179th Street, Lakeville, MN Topaz - Payton XL 5710 Upper 179th Street, Lakeville, MN 5/27/2020; #24120 Page 22 / 25 Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (lbs)1858 @ 0 1913 (1.50")Passed (97%)--1.0 D + 1.0 L (All Spans) Shear (lbs)990 @ 10 3/4"2498 Passed (40%)1.00 1.0 D + 1.0 L (All Spans) Moment (Ft-lbs)1781 @ 1' 11"3431 Passed (52%)1.00 1.0 D + 1.0 L (All Spans) Live Load Defl. (in)0.012 @ 1' 11"0.128 Passed (L/999+)--1.0 D + 1.0 L (All Spans) Total Load Defl. (in)0.017 @ 1' 11"0.192 Passed (L/999+)--1.0 D + 1.0 L (All Spans) System : Wall Member Type : Header Building Use : Residential Building Code : IBC 2018 Design Methodology : ASD •Deflection criteria: LL (L/360) and TL (L/240). •Top Edge Bracing (Lu): Top compression edge must be braced at 3' 10" o/c based on loads applied, unless detailed otherwise. •Bottom Edge Bracing (Lu): Bottom compression edge must be braced at 3' 10" o/c based on loads applied, unless detailed otherwise. •Applicable calculations are based on NDS. Bearing Length Loads to Supports (lbs) Supports Total Available Required Dead Floor Live Total Accessories 1 - Trimmer - SPF 1.50"1.50"1.50"517 1342 1859 None 2 - Trimmer - SPF 1.50"1.50"1.50"517 1342 1859 None Dead Floor Live Vertical Loads Location (Side)Tributary Width (0.90)(1.00)Comments 0 - Self Weight (PLF)0 to 3' 10"N/A 7.0 -- 1 - Uniform (PSF)0 to 3' 10"17' 6"15.0 40.0 Floor - Main Level Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/document-library. The product application, input design loads, dimensions and support information have been provided by NH; plan dated 4/13/2020. Weyerhaeuser Notes All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal. MEMBER REPORT PASSED Lower Level, Mechanical Room Door 2 piece(s) 2 x 10 Spruce-Pine-Fir No. 1 / No. 2 ForteWEB Software Operator Job Notes 5/27/2020 7:43:49 PM UTCJeffrey Doty, Design Supervisor Lyman Lumber Company (952) 470-4866 jeff_doty@lymanlumber.com ForteWEB v2.4, Engine: V8.0.1.5, Data: V7.3.2.0 File Name: 5710 Upper 179th Street, Lakeville, MN Topaz - Payton XL 5710 Upper 179th Street, Lakeville, MN 5/27/2020; #24120 Page 23 / 25 Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (lbs)2918 @ 2' 9"3806 (1.50")Passed (77%)--1.0 D + 1.0 L (All Spans) Shear (lbs)808 @ 1' 10"6872 Passed (12%)1.00 1.0 D + 1.0 L (All Spans) Moment (Ft-lbs)1347 @ 1' 8 11/16"10422 Passed (13%)1.00 1.0 D + 1.0 L (All Spans) Live Load Defl. (in)0.008 @ 1' 5 3/16"0.092 Passed (L/999+)--1.0 D + 1.0 L (All Spans) Total Load Defl. (in)0.011 @ 1' 5 3/16"0.138 Passed (L/999+)--1.0 D + 1.0 L (All Spans) System : Wall Member Type : Header Building Use : Residential Building Code : IBC 2018 Design Methodology : ASD •Deflection criteria: LL (L/360) and TL (L/240). •Top Edge Bracing (Lu): Top compression edge must be braced at 2' 9" o/c based on loads applied, unless detailed otherwise. •Bottom Edge Bracing (Lu): Bottom compression edge must be braced at 2' 9" o/c based on loads applied, unless detailed otherwise. Bearing Length Loads to Supports (lbs) Supports Total Available Required Dead Floor Live Total Accessories 1 - Trimmer - SPF 1.50"1.50"1.50"441 1120 1561 None 2 - Trimmer - SPF 1.50"1.50"1.50"843 2075 2918 None Dead Floor Live Vertical Loads Location (Side)Tributary Width (0.90)(1.00)Comments 0 - Self Weight (PLF)0 to 2' 9"N/A 10.4 -- 1 - Uniform (PSF)0 to 2' 9"16' 3"15.0 40.0 Floor - Main Level 2 - Uniform (PSF)2' 3" to 2' 9"1'90.0 -Wall - Main Level 3 - Uniform (PSF)2' 3" to 2' 9"16' 3"15.0 40.0 Floor - Upper Level 4 - Point (lb)2' 3"N/A 418 1083 Linked from: Mudroom Kitchen Opening , Support 2 Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/document-library. The product application, input design loads, dimensions and support information have been provided by NH; plan dated 4/13/2020. Weyerhaeuser Notes All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal. MEMBER REPORT PASSED Lower Level, Bathroom Door 2 piece(s) 1 3/4" x 9 1/2" 1.55E TimberStrand® LSL ForteWEB Software Operator Job Notes 5/27/2020 7:43:49 PM UTCJeffrey Doty, Design Supervisor Lyman Lumber Company (952) 470-4866 jeff_doty@lymanlumber.com ForteWEB v2.4, Engine: V8.0.1.5, Data: V7.3.2.0 File Name: 5710 Upper 179th Street, Lakeville, MN Topaz - Payton XL 5710 Upper 179th Street, Lakeville, MN 5/27/2020; #24120 Page 24 / 25 Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (lbs)1239 @ 0 1913 (1.50")Passed (65%)--1.0 D + 1.0 L (All Spans) Shear (lbs)432 @ 10 3/4"2498 Passed (17%)1.00 1.0 D + 1.0 L (All Spans) Moment (Ft-lbs)852 @ 1' 4 1/2"3431 Passed (25%)1.00 1.0 D + 1.0 L (All Spans) Live Load Defl. (in)0.003 @ 1' 4 1/2"0.092 Passed (L/999+)--1.0 D + 1.0 L (All Spans) Total Load Defl. (in)0.004 @ 1' 4 1/2"0.138 Passed (L/999+)--1.0 D + 1.0 L (All Spans) System : Wall Member Type : Header Building Use : Residential Building Code : IBC 2018 Design Methodology : ASD •Deflection criteria: LL (L/360) and TL (L/240). •Top Edge Bracing (Lu): Top compression edge must be braced at 2' 9" o/c based on loads applied, unless detailed otherwise. •Bottom Edge Bracing (Lu): Bottom compression edge must be braced at 2' 9" o/c based on loads applied, unless detailed otherwise. •Applicable calculations are based on NDS. Bearing Length Loads to Supports (lbs) Supports Total Available Required Dead Floor Live Total Accessories 1 - Trimmer - SPF 1.50"1.50"1.50"345 894 1239 None 2 - Trimmer - SPF 1.50"1.50"1.50"345 894 1239 None Dead Floor Live Vertical Loads Location (Side)Tributary Width (0.90)(1.00)Comments 0 - Self Weight (PLF)0 to 2' 9"N/A 7.0 -- 1 - Uniform (PSF)0 to 2' 9"16' 3"15.0 40.0 Floor - Main Level Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/document-library. The product application, input design loads, dimensions and support information have been provided by NH; plan dated 4/13/2020. Weyerhaeuser Notes All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal. MEMBER REPORT PASSED Lower Level, Bedroom #4 Closet Door 2 piece(s) 2 x 10 Spruce-Pine-Fir No. 1 / No. 2 ForteWEB Software Operator Job Notes 5/27/2020 7:43:49 PM UTCJeffrey Doty, Design Supervisor Lyman Lumber Company (952) 470-4866 jeff_doty@lymanlumber.com ForteWEB v2.4, Engine: V8.0.1.5, Data: V7.3.2.0 File Name: 5710 Upper 179th Street, Lakeville, MN Topaz - Payton XL 5710 Upper 179th Street, Lakeville, MN 5/27/2020; #24120 Page 25 / 25 Date Certificate Posted X Passive (No Fan) Active (With fan and monometer or other system monitoring device) Location (or future location) of Fan: Other Please Describe Here R-15 X R-20 X R-20 X R-20 X R-49 X R-49 X R-30 X R-30 X X Not applicable, all ducts located in conditioned space X Not required per mech. code Passive Powered Interlocked with exhaust device. Describe: Input in BTUS: 70,000 Capacity in Gallons: Other, describe: AFUE or HSPF% 92.1 Cfm's " round duct OR " metal duct Not required per mech. code X Passive X Low: Other, describe: Low: Location of fan(s), describe: Cfm's X " round duct OR 6" flex " metal duct City Mailing Address of the Dwelling or Dwelling Unit Combustion Air Select a Type Location of duct or system: 2 Below Entire Slab Rigid, Extruded Polystyrene Ceiling, flat Per R401.3 Certificate. A building certificate shall be posted on or in the electrical distribution panel.5/28/2020 New Construction Energy Code Compliance Certificate Name of Residential Contractor One Ten Ten Homes, LLC MN License Number Lakeville5710 Upper 179th St. BC730925 Mechanical room 110Heat Recover Ventilator (HRV) Capacity in cfms: Energy Recover Ventilator (ERV) Capacity in cfms: 60333 Heating Gain Cooling Load Fuel Type Solar Heat Gain Coefficient (SHGC): Windows & Doors Ceiling, vaulted Bay Windows or cantilevered areas Floors over unconditioned area Rim Joist (2nd Floor+) 0.28 Appliances THERMAL ENVELOPE Foam Open Cell Wall Rigid, Isocynurate Perimeter of Slab on Grade RADON CONTROL SYSTEM Non or Not Applicable Cooling SystemTotal R-Value of all Types of InsulationType: Check All That Apply Mineral Fiberboard Insulation Location Foam, Closed Cell0.21 Describe other insulated areas Fiberglass, BlownFiberglass, Batts Foundation Wall R-value Average U-Factor (excludes skylights and one door ) U: Duct system air tightness: Building envelope air tightness: Rim Joist (1st Floor) GPVL5000L 4AC13N36P Model Heating System Natural Gas Aireflow Location of duct or system: Heating or Cooling Ducts Outside Conditioned Spaces Electric Make-up Air Select a Type AO Smith Domestic Water Heater MECHANICAL SYSTEMS Rating or Size Efficiency 13 Select Type Describe any additional or combined heating or cooling systems if installed: (e.g. two furnaces or air source heat pump with gas back-up furnace): 26610Residential Load Calculation SEER /EER 200 Total ventilation (intermittent + continuous) rate in cfms: Balanced Ventilation capacity in cfms: High: High: MECHANICAL VENTILATION SYSTEM Capacity continuous ventilation rate in cfms: 92AF1UH070P12B Heating Loss Manufacturer Aireflow Natural Gas Output in Tons: 250 Builders Associaton of Minnesota version 101014 05/29/2020 X KP