Loading...
HomeMy WebLinkAboutLA184286 17960 Gresford Lane Permit PackRESIDENTIAL BUILDING PERMIT APPLICATION CITY OF LAKEVILLE BUILDING INSPECTIONS DEPARTMENT 20195 HOLYOKE AVENUE LAKEVILLE, MN 55044 952-985-4440 Office Use Only __________________ Permit Number ___________________ Received By ___________________ Date Received ___________________ Fee Total SITE ADDRESS: MAILING ADDRESS: CITY: STATE: ZIP: JOB DESCRIPTION:__________________________________ MASTER PLAN: (Number or Address)____________________ LIST OTHER STRUCTURES ON PROPERTY:_______________________________________________________________ ESTIMATED VALUATION: PROPOSED START DATE: END DATE: (New Residential Only): LEGAL DESCRIPTION: LOT: _____ BLOCK: _____ SUBDIVISION: APPLICANT IS: RESIDENT OWNER CONTRACTOR EMAIL NEW MODEL HOME: YES NO (IF YES – ADMINISTRATIVE PERMIT REQUIRED) PLEASE FILL OUT THE FOLLOWING COMPLETELY (All Contractor information must be as listed on State License) RESIDENT OWNER NAME:_______________________________________________________________________________ HOME PHONE #:_____________________________ CELL PHONE:___________________________ GENERAL CONTRACTOR Homeowner Contractor CONTRACTOR:_______________________________________________________________________ LICENSE #:BC______________ LEAD CERTIFICATE#_______________ (PRE 1978 STRUCTURE) OFFICE PHONE #:_____________________________ CELL PHONE:___________________________ ADDRESS:____________________________ CITY:________________ ST:______ ZIP:____________ PLUMBING WORK Homeowner Contractor CONTRACTOR:__________________________________________LICENSE #: PM______________ OFFICE PHONE #:_____________________________ CELL PHONE:___________________________ ADDRESS:____________________________ CITY:________________ ST:______ ZIP:____________ MECHANICAL WORK Homeowner Contractor CONTRACTOR:________________________________________ _______________________________ OFFICE PHONE #:_____________________________ CELL PHONE:___________________________ ADDRESS:____________________________ CITY:________________ ST:______ ZIP:____________ BOND #:_______________________________________ EXPIRATION DATE____________________ SEWER/WATER CONTRACTOR New Construction Only NAME:________________________________________________ ______________________________ HOME PHONE _____________________________ CELL PHONE:______________________________ BOND #:_______________________________________ EXPIRATION DATE____________________ INTEREST EARNINGS ON THE ESCROW ACCOUNTS, IF ANY, ARE RETAINED BY THE CITY TO OFFSET THE ADMINISTRATIVE COSTS ASSOCIATED WITH PROCESSING THE ESCROW APPLICATION AND REFUND. I HEREBY APPLY FOR A BUILDING PERMIT AND I ACKNOWLEDGE THAT THE INFORMATION ABOVE IS COMPLETE AND ACCURATE; THAT THE WORK WILL BE IN CONFORMANCE WITH THE ORDINANCES AND CODES OF THE CITY AND WITH THE STATE BUILDING CODE, THAT I UNDERSTAND THIS IS NOT A PERMIT AND WORK IS NOT TO START WITHOUT A PERMIT AND THAT THE WORK WILL BE IN ACCORDANCE WITH THE APPROVED PLAN. NAME OF APPLICANT (Please Print)DATE APPLICANT’S SIGNATURE: www.lakevillemn.gov CANNOT HOOK TO CITY SEWER/WATER RESIDENTIAL BUILDING PERMIT APPLICATION PAGE 2 OFFICE USE ONLY BUILDING PERMIT TYPE REQUIRED INSPECTIONS SINGLE FAMILY DWELLING BUILDING DUPLEX AS BUILT TOWNHOUSE UNITS BUILDING FINAL DETACHED TOWN HOUSE UNIT DECK FOOTING CONDO FIREPLACE ACESSORY BUILDING FOOTING REROOF FOUNDATION RESIDE FRAMING PORCH FRAMING GARAGES INSULATION RES ADDN/REPAIR/RMDL DECK PORCH GARAGES LATH LOWER LEVEL FINISH LOWER LEVEL FINAL ADDITION OTHER FOUNDATION ONLY PORCH FOOTING MISCELLANEOUS POURED WALL DEMO SEPTIC TANK REMOVAL MOVED SITE MECHANICAL CITY BUILDING VALUATION: $AIR TEST FINAL BUILDING PERMIT FEES ROUGH-IN $PERMIT FEE PLUMBING $PLAN CHECK FINAL $SURCHARGE ROUGH-IN $METRO SAC METER SIZE $CITY WATER HOOKUP UNIT PRESSURE REDUCING VALVE $CITY SEWER HOOKUP UNIT SEWER/WATER $LANDSCAPE ESCROW SEWER/WATER $TREE ESCROW FINAL $MISC ESCROW STREET DRAINTILE $PLUMBING BUILDING INFORMATION $MECHANICAL TYPE OF CONSTRUCTION $SEWER WATER ZONING $OTHER CODE EDITION $TOTAL FIRE SUPPRESSION SYSTEM OCCUPANCY GROUP APPROVED BY: BUILDING INSPECTOR: Date: PLUMBING/MECHANICAL INSPECTOR: Date: COMMENTS: 20195 Holyoke Avenue, Lakeville, MN 55044 952-985-4400  952-985-4499 fax www.lakevillemn.gov Sewer & Water Tie Card Address:________________________________________ Contractor:______________________________________ Permit Number:__________________________________ Final Date:________________ Street Drain-Tile:______ Size of Water Service: 1” Comments: AIRTEST SANITARY OVER 20’/2 FITTINGS THIS CARD MUST BE COMPLETED AND ON-SITE AT TIME OF SEWER & WATER INSPECTION 1 9 07-00-BUYERPROJECT # BUYER S/O BUYER S/O REVISIONS: STARTED: AGENT:X XLOT 5, BLOCK 8, SUMMERS CREEK17960 GRESFORD LN., LAKEVILLE, MN"RICHMOND" 1640 VILLA HOMEMARK ELLIOTT HOMES7-20-2020 PERMIT 8-4-2020 REV. #1 8-28-2020 REV. #2 OF SHEET GENERAL NOTES: 1. ALL DOOR AND WINDOW HEADERS TO BE S.P.F. #2 OR BETTER, SEE PLANS FOR SIZES. 2. HOUSE TO BE BUILT PER CURRENT I.R.C. CODES. 3. VERIFY GRADES AND ADJUST FOUNDATION/FOOTING STEPS AS NEEDED. 4. SEE PLANS FOR CEILING HEIGHTS 5. 4' HIGH POURED FDN. WALLS STD. 6. FLOOR PLAN DIMENSIONS ARE TO FACE OF FRAMING AND FOUNDATION. 7. ALL TRADES & SUPPLIERS TO REVIEW & VERIFY INFORMATION PERTINENT TO THEIR WORK AND NOTIFY CONST. OF ANY DISCREPANCIES PRIOR TO CONSTRUCTION. 8. NOTED CABINET SIZES ARE +/- AND TO BE FIELD VERIFIED. 9. TRADES TO VERIFY BASE AND TRIM SIZE PRIOR TO CONSTRUCTION. 10. ALL WALLS MORE THAN 10' H. TO BE S.P.F. #2 OR BETTER. 11. EXTERIOR ELEVATIONS ARE CONCEPTUAL ONLY: HOME SITE, FILL AND TOPOGRAPHY WILL DICTATE ACTUAL GRADES AND MAY VARY FROM THOSE SHOWN ON THE PLAN. 12. NOTE: SUBFLOOR JOINTS SHALL BE STAGGERED FROM FLOOR TRUSS OR JOIST JOINTS SCALE: 1/8" = 1'-0" FRONT ELEVATION SEE ROOF PLAN FOR ROOF PITCHES AND OVERHANGS 24'-9"CONC. PORCH 4" TRIM TYP. 6:12 ALUM. SOFFIT & FASCIA 30 YR. ARCH. ASPHALT SHINGLES 6" TRIM 10" TRIM TAPERED LP COLUMN7'-0"9'-1 1/8"T.O. SUBFLR. T.O. PLATE 1'-8 1/4"T.O. FDN.8" TRIM 9'-9 1/8"@ GARAGE T.O. PLATE 12 12 12 12 2x OVER 10" TRIM 1'-6"7'-2 1/2"T.O. 6024 PICT. (BLACKENED) 3:12 12" CANT. 10" TRIM C/L LP SMARTSIDE SHAKE SIDING T.O. FDN.7'-9"@ DORMERT.O. PLATE 10'-4"FP CHASE24"x60" FALSE LP PANEL 8" TRIM 8" TRIM LP PANEL LP PANEL12" TRIM12" TRIM1'-6" 1'-2" 4"x24" BRACKET GLS.GLS.GLS.GLS. STONE TOTAL: 137.61 SQ. FT. (41.79%) TOTAL SQ. FT.: 329.27 MATERIAL CALCULATIONS: FRONT ELEV. LP SHAKE TOTAL: 93.49 SQ. FT. (28.39%) LP TRIM / PANEL: 92.7 SQ. FT. (29.82%) STONE TOTAL: 186.54 SQ. FT. (7.30%) TOTAL SQ. FT.: 2555.04 MATERIAL CALCULATIONS: ALL ELEV. LP LAP SIDING TOTAL: 1808.80 SQ. FT. (70.79%) LP SHAKE TOTAL: 245.27 SQ. FT. (9.61%) LP TRIM / PANEL: 314.43 SQ. FT. (12.30%)2'-6" +/-6" TRIM 6" TRIM 6" TRIM STONECAP Concept Approval ONLYSubject to Field Inspection Inspector Date 2020 MN Bldg Code 09/23/2020dmathews EXTERIOR ELEVATIONS ARE CONCEPTUAL ONLY: HOME SITE, FILL AND TOPOGRAPHY WILL DICTATE ACTUAL GRADES AND MAY VARY FROM THOSE SHOWN ON THE PLAN.2 9 07-00-BUYERPROJECT # BUYER S/O BUYER S/O REVISIONS: STARTED: AGENT:X XLOT 5, BLOCK 8, SUMMERS CREEK17960 GRESFORD LN., LAKEVILLE, MN"RICHMOND" 1640 VILLA HOMEMARK ELLIOTT HOMES7-20-2020 PERMIT 8-4-2020 REV. #1 8-28-2020 REV. #2 9-18-2020 REV. #3 OF SHEET SIDE ELEVATION REAR ELEVATION SCALE: 1/8" = 1'-0" SIDE ELEVATION SCALE: 1/8" = 1'-0" SCALE: 1/8" = 1'-0"12:12 ALUM. SOFFIT& FASCIA STONE ROOF LINEBEYOND 12 6 T.O. PLATE 9'-1 1/8"T.O. SUBFLR. T.O. FDN.1'-8 1/4"12 6 10" TRIM 12" CANT.4" LP TRIM @ WDWS. & DOORS TYP. PER SPECS FP VENT SADDLE SEE ROOF PLAN FOR PITCHES AND OVERHANGS 12:12 12:12 2x OVER 12" TRIM LP PANEL8" TRIM LP LAP SIDING T.O. PLATE 9'-1 1/8"T.O. SUBFLR. T.O. FDN.1'-8 1/4"4" LP TRIM @ WDWS. & DOORS TYP. SEE ROOF PLAN FOR PITCHES AND OVERHANGS ALUM. SOFFIT & FASCIA 6:12 LP LAP SIDING PER SPECS 2x OVER 12" TRIM 12" CANT. 12 12 12 12 @ GARAGE 9'-9 1/8"T.O. FDN.A/C UNIT T.O. PLATE 9'-1 1/8"T.O. SUBFLR. T.O. FDN.1'-8 1/4"10" TRIM 4" LP TRIM @ WDWS. & DOORS TYP. 12 6 12 6 12 3.5 T.O. PLATE5'-9"@ DORMER T.O. PLATE ALUM. SOFFIT & FASCIA PER SPECS SEE ROOF PLAN FOR PITCHES AND OVERHANGS 12:12 12:12 12:12 2x OVER 12" TRIM2x OVER 10" TRIMLP PANEL8" TRIM LP SHAKE SIDING LP LAP SIDING SCALE: 1/8" = 1'-0" FOUNDATION PLAN 3 9 07-00-BUYERPROJECT # BUYER S/O BUYER S/O REVISIONS: STARTED: AGENT:X XLOT 5, BLOCK 8, SUMMERS CREEK17960 GRESFORD LN., LAKEVILLE, MN"RICHMOND" 1640 VILLA HOMEMARK ELLIOTT HOMES7-20-2020 PERMIT 8-4-2020 REV. #1 8-28-2020 REV. #2 OF SHEET A/C UNIT w/ BRACKET FURN F.D. WH MECH. / STORAGE WS FUT. 3068FUT. 2 6 68 FUT. BDRM. #5 FUT. FAMILY ROOM R.I. BATH FUT. 36" V.CONC. H.B. H.B. 2" LEDGE TYP. TO PROVIDE ADD'L.SUPPORT FOR FILL FOR SLAB TYP. FND @ HOUSE / GARAGE 10" POURED CONC. W/ 4" LEDGE INSIDE 20X8 CONC. FTG. 2" FOAM SUMP H20 4" LEDGE 2" FOAM TYP. FND @ STOOP 12" POURED CONC. W/ 4" LEDGE INSIDE 20X8 CONC. FTG. UNEXCAVATED 2" NOTE: NO DRYWALL @ CLG.REQUIRED IN THIS AREA -FIRE BLOCK @ PERIMETEROF OPNG. (80 SQ. FT. MAX.) 6"2" RADON VENT TOTERMINATE IN SUMP BASKET 6" 4" 10" GARAGE/HOUSE COMMON WALL 2x8 TREATED SILLOVERHANG FDN. 2'' GARAGE SLAB 2'' RIGID INSUL. MAIN FLR SEE FIRST FLOOR FORGARAGE DOOR SIZE FOR M.O. NOTE: 4" LEDGE 6"2"CONC. CONC. 3 1/2'' CONC. FLOOR TYP. FND @ HOUSE 8" POURED CONC. (9' H.)20X8 FTGREBAR PER CODE TYP. FND @ BRG. WALL 2x4 STUDS 16" O.C. 16X8 FTGREBAR PER CODE 4" CONC. CURB KITCHEN ISLAND ABV. FLR. TRUSS CO. FU T . 2 4 6 8 OPT.18" FLR. TRUSSES19.2" O.C. SPACING2-2x10 (DR) (9'-3"x12'-7") (25'-6"x12'-6") RADON VENT NOTE: EXTERIOR HOUSE AND GARAGE/HOUSECOMMON FDN. WALLS TO BE HELD 2'' IN. DIMENSIONS SHOWN ARE TO FACE OF 2'' EXTERIOR RIGID INSULATION & FRAMING ABOVE TO BE 5000 PSI CONC.NOTE: ALL FOOTINGS 2'' MIN. 2x8 TREATED SILL-OVERHANGFDN. 1 1/2''8"2" TYP. SIDEWALL DETAIL FOUND. HELD IN 2" FOR INSULATION NOTE: (TYP.)2"2"2"2" 9'-0" POURED FDN. APPROX. 1,634 NET SQ. FT. FILL FOR SLAB UP 15 R (10" T., 7-3/4" MAX. R.) 14'-6"12'-0"56'-0"6'-0"50'-0"66'-0"4'-0"29'-0"33'-0"15'-0"14'-0"10'-6 1/2"10'-0"12'-0"2'-0"19'-0"40'-0" 19'-0"21'-0" 19'-5 1/2" & HOUSE/PORCH 10'-9"10'-3"18" FLR. TRUSSES19.2" O.C. SPACING3-9 1/2" LSL (DR) FOUND. HELD IN 2" FOR INSULATION NOTE: (TYP.) FUT. 2 0 6 8 32x60FUT. TUB / SH2x10 TRTD. JOISTS16" O.C. SPACING3-2x10 TRTD. (FL) SMOKECM / 12" CANT. ABV.2x6 BRG.2x6 BRG. 10' H. FOUND. WALL @ FRONT OF HOME NOTE: 10' H. FOUND. WALL@ FRONT OF HOME NOTE: w/ TOP HUNG TRUSSES w/ TOP HUNG TRUSSES 10' H. FOUND. WALL@ FRONT OF HOME NOTE: w/ TOP HUNG TRUSSES 10'-6"10'-6"19'-0" 11'-8 3/4"3'-2"15'-1 1/4"10'-0"3'-9"3'-10"6'-4"21'-6 1/2"9'-2 1/2"19'-3"9'-1 1/2"10'-4" 30"x30" CONC.PAD FTG. 6x6 COL. 16" DIA. FROSTFOOTING (60" D.) 6x6 TRTD. COL. 2-2x10 (FL) (2) TR 3-9 1/2" LSL (DR)3'-1"2'-10"2'-4"FUT. 24683'-2"2'-8"4'-0"3'-8"10'-0"9'-5 1/2"13'-11 1/2"20'-0" 8'-0"12'-0" 40'-0" 6'-9"6'-9" 5'-0"4'-0"CONC. WDW WELL 3042 CSMT 2-9 1/2" LSL3'-8"4'-11" 26'-6"13'-6"FUT. 2668UFER GROUND Provide 20' rebar in footing and stub up near electrical service panel for UFER ground. SCALE: 1/8" = 1'-0" MAIN FLOOR PLAN 4 9 07-00-BUYERPROJECT # BUYER S/O BUYER S/O REVISIONS: STARTED: AGENT:X XLOT 5, BLOCK 8, SUMMERS CREEK17960 GRESFORD LN., LAKEVILLE, MN"RICHMOND" 1640 VILLA HOMEMARK ELLIOTT HOMES7-20-2020 PERMIT 8-4-2020 REV. #1 8-28-2020 REV. #2 OF SHEET P.H.TBTR DW GAS RANGEMICRO ABV. FLUSH OH. LNDRY. DRYER WASHER 9' CLG. / LVP WIRE SH. 29 (OPT. UPPERS) 39 (VENT TO OUTSIDE)NOTE: - STD. BASE & CASING TO BE PRINCETON - 1/2 WALL w/ WD. CAP & INVERTED CASING NOTE: 2X6 EXT. WALLS U.N.O.2X4 INT. WALLS U.N.O. - 42" UPPER CABINETS DOOR ROUGH OPENINGS: 83" HEIGHT 82" OVER VINYL CERAMIC TILE & WOOD 82" OVER CARPET SRO = SHEET ROCKED OPNG BIFOLD DOORS: PREHUNG UNITS: 2" WIDER THAN DOOR (EXAMPLE: 2668 ) 1 3/8" WIDER THAN DOOR FINISH SIZE NOTED ON PLAN CO = CASED OPENING ( WOOD ) (EXAMPLE: 2668 ) FINISH SIZE NOTED ON PLAN RO. 1 1/2" WIDER, 83" HIGH R.O. 1" WIDER, 83" HIGH PER SPECS DRIVEWAY NOTE: REF. 49KITCHEN 9' CLG. / LVP13'-2" x 12'-6" (155 SQ. FT.) 69BUILT-INS89 3-16" LVL GREAT ROOM 9' CLG. / LVP FLR.42" GAS F.P.12'-8" x 13'-0" (170 SQ. FT.) / LVP 42" W. CONC. SIDEWALKOPT.FIBRGLS. 60x36 SHWR. UNIT 5'-0" 2 1 0 6 8 FOYER 9' CLG. / LVP5'-10" x 11'-8" (69 SQ. FT.) PORCH CONC. / O. BATH 9' CLG. / VIN. 2x6 WALLS U.N.O.4" SLOPED CONC. GARAGE CEIL. TO BE 5/8" TYPE 'X'GYP. BD. WALLS TO BE 1/2" GYP.SHEATHING. ALL WALLS & CEILINGS TOHAVE ONE COAT FIRETAPE GARAGE SLOPE CONC.6'x8' PATIO DR. 16'x7' O.H.D.R.O. 16'-1" FRAMING O. CLST 8' CLG. / CARPET 36" VAN. BATH BEDROOM #2 / OFFICE26683648 SH @ 8'9' CLG. / CARPET w/ WD. CAPMANUF. TRUSSES24 O.C.OPT. BUFFET CABS. (12'-3"x12'-0") EXTERIOR FLOOR PLAN DIMENSIONS ARE TO OUTSIDE OF SHEATHING, INTERIOR DIMENSIONS ARE TO FRAMING. NOTE: ALL DRS/ WIN.'S REQUIRE 4" ON SIDES FOR CASING NOTE: 2X6 EXT. WALLS U.N.O.2X4 INT. WALLS U.N.O. HEADER SPANS: UP TO 4'-11'' = 1 TRIMMER 5'-0'' AND BIGGER = 2 TRIMMERS UNLESS NOTED OTHERWISE INDICATES LOCATION OF SOLID BRG. (150 SQ. FT.) OWNERS BDRM. 9' CLG. / CARPET(12'-6"x13'-7") (173 SQ. FT.) SMOKECM / SD 2 - 4072 SH @ 8' DN 15 R (10" T., 7-3/4" MAX. R.) 8/0 H. SOFFIT MANUF. TRUSSES 24 O.C.TAPERED LP COL. * BEADBD. CLG.ATTICACCESSAPPROX. 553 SQ. FT. MUDRM. 9' CLG. / LVP APPROX. 9'-0'' CLG. @ MAIN LEVEL APPROX. 1,634 SQ. FT. OPT. PORCH 3 0 6 8 M T L .3080 MTL.2468R&SH R&SH9' CLG. / CARPET 9' CLG. 8' SOFFIT 28682668R&SHR&SH36" VAN. LIN.CAB. 3068FLDG. C'TOP.(OPEN UNDER) 2 - 4072 SH @ 8'30" VAN. DINING 9' CLG. / LVP FLR.11'-0" x 12'-10" (146 SQ. FT.) 3672 SH @ 8'3672 SH @ 8'4872 PICT. @ 8' 12'x10' DECK DECKING PER SPECS OPT. 15'X10' EXP. DECK MANUF. TRUSSES24 O.C.40'-0" 14'-6"12'-0" 8'-6"11'-10"6'-2"6'-9"66'-0"6'-0"50'-0"12'-8"4'-10"5'-8"12'-8 3/4"7"3'-11"5'-2 1/2"4'-4 3/4"7'-8 1/4"5'-0 1/2"66'-0"4'-0"29'-0"33'-0"6'-9 1/2"14'-4"3'-2"10'-6 1/2"10'-0"12'-0"2'-0"19'-0"40'-0" 19'-0"21'-0" 8'-0" 13'-0"6'-0" 6'-7"6'-5" 10'-9"10'-3" RADON VENT 6'-10"7"12'-0" LSL (FL)LP SOFFIT SD SMOKECM / OPT. VAULT79 19 BUILT-INSOPT.2'-4 1/4"1'-10 1/2"2424 PICT. @ 8'2424 PICT. @ 8'2'-0 1/2"2'-0 1/2" 3068 BARN DR.OPT. EXP.ISLAND 2448 SH @ 8'5'-0"WD. STEP 3'-11 1/4"6'-0 3/4" 2'-0" 16'-10 1/2" 2'-7 1/2"2'-4"4'-0"5'-0"12" CANT.4'-4"10'-0"3'-9"3'-9"3'-0"3'-0"2-2x102-2x102-2x102-2x104 1/2"4 1/2"MANUF. TRUSSES24 O.C.FP CHASEFALSE 2-9 1/2" LSL (CONT.)2-9 1/2" LSL 2-2x10 (2) TR 2-2x10 P.H. TR 4x4 TRTD. COL. 59 3068 PKT.3'-6"6'-0"3'-6"3'-0"13'-6" 6'-9" 26'-6"10'-0"21 0 6 8 TR R&SH R&SH 1/2 WALL R&SHR&SH 26689'-7 1/2"9'-6 1/2"2668PANTRY 9' CLG. / LVP (5) SH. 9' CLG. / LVP 2468R&SH2/10 x 6/7 SRO6'-0 3/4"4'-3"2'-10 1/2"6'-8 3/4"7"2'-5"4'-8 1/2"5'-10"12'-2 3/4"7"6'-2 1/4"5'-7 3/4"2'-5 1/2"5'-7"4'-9 1/4" 1'-0" 11"5'-2"5'-10"2'-1"2'-5 1/4"2x65'-11 1/4" 3'-9" 8'-4" GIRDER TRUSS (3) 2x6 (3) 2x6 MANUF. TRUSSES 24 O.C. 9 1/2"7'-10 1/2"2'-3"7"7"GIRDER TRUSS (4) 2x6 (4) 2x6 2-7 1/4" LSL (FL)2-7 1/4" 2-2x10 2-2x10 32x60FGLS.TUB / SHPA 7" OPT. 2 6685'-0"5'-8"2'-10" OPT. UPGRADED KITCHEN MICRO/ OVEN DW GAS RANGEMICRO ABV. FLUSH OH. 29 39 (VENT TO OUTSIDE)REF. 49KITCHEN 9' CLG. / LVP13'-2" x 12'-6" (155 SQ. FT.)3648 SH @ 8'12'-8 3/4"7"7'-8 1/4"5'-0 1/2"OPT. EXP.ISLAND 2'-4"2-2x103'-6"6'-0"3'-6"3'-0"3'-9" Temper Verify loads with girder truss specs, may require removal of top plates at bearing due to crushing. CO required within 10' of bedroom CS-PF CS-PF 6 8 -Min. 15" clearance to any obstruction from center of W.C., 24" in front(typ). 8 5 9 07-00-BUYERPROJECT # BUYER S/O BUYER S/O REVISIONS: STARTED: AGENT:X XLOT 5, BLOCK 8, SUMMERS CREEK17960 GRESFORD LN., LAKEVILLE, MN"RICHMOND" 1640 VILLA HOMEMARK ELLIOTT HOMES7-20-2020 PERMIT 8-4-2020 REV. #1 8-28-2020 REV. #2 OF SHEET SCALE: 3/16" = 1'-0" SECTION1 5 N.T.S. HOUSE / DECK CONNECTION DETAIL4 5 JOIST W/ 2-3/8" LAG BOLTS ICE & WATER EXTENDS5" UP SHEATING UNDER INSTALL TOP OF LEDGER3 5/8" BELOW TOP OF3/4" SUBFLOOR (THIS ALLOWS 5/4 X 4 THRESHOLDAT DOOR) HANGER TREATED 2X10 LEDGER RUN HOUSE WRAP BEHINDLEDGER (LEAVE 6" TAIL@ TOP, BOTTOM, & SIDES) HOUSEWRAP @ 24" O.C. -OR- EMBED 2" MIN.8 INCHES O.C. MAX OR EQUAL,W/ "LEDERLOK" FASTENERS CONT. 2X4 RIBBON SPRAY FOAM INSUL. R-21 MIN.RIM BOARD TREATEDJOIST JOISTRIM BD.SKIRT 1" HOUSE END OF DECK HOUSE LATERAL LOAD SIMPSON DTT1Z DECK-TO CONNECTOR - (4) PER DECK OR 8-10DX1 1/2" NAILS 6-SD#9X1 1/2" SCREWS HDG WASHER OR SDWH 3/8" HDG LAG SCREW WITH TIMBER-HEX HDG SCREW (SHOWN) INTO TOP PLATE, STUDS, OR HEADER CONT. 2X8 RIBBON DRAIN TILE 3/4" WASHED ROCKCONTINUOUSUNDER SLAB0'-16" SILT FABRIC FOUNDATION WALL CONC. FTG. 4" DRAIN TILE 2 SCALE: NO SCALE5 TOP OF FDN.RIM DETAIL3 SCALE: NO SCALE5 2" RIGID INSULATION R-10 w/ WATCHDOGWATERPROOF COATINGAROUND HOUSE FOUND. 2" RIGID INSULATION R-10 w/ WATCHDOGWATERPROOF COATINGAROUND HOUSE FOUND. 2x8 TRTD. SILL SHEATHING FLUSHWITH INSULATION NOTE: FOUNDATION TO BEHELD IN 2" FROMSHEATHING & OUTSIDEDIMENSIONS. CANTED 1-1/2" 3/4" T & G FLOOR NOTE: SUBFLOOR JOINTS SHALL BESTAGGERED FROM FLOOR TRUSS ORJOIST JOINTS R=0.61 R=49.00 R=50.25 R=0.58 R=.061 TOTAL TRUSSES - 24" OC BLOWN INSULATION INTERIOR AIR FILM VAPOR BARRIER 15/32" OSB SHTG. 15# FELT EXTERIOR AIR FILM ICE AND SNOW SHIELD 30 YR. ARCH. ASPHALT SHINGLES 5/8" GYP BD ALUM. SOFFIT & FASCIA 1/2" GYP BD INTERIOR AIR FILM TOTAL SIDING PER SPECS 2x6 STUDS 16" OC R=1.06 R= R= R=21.00 R=0.45 R=0.17 R=23.36 VAPOR BARRIER FULL WALL BATT INSUL. EXTERIOR AIR FILM R=0.68 7/16" OSB SHTG. 8" AGGREGATE6 MIL POLY. LAP SEAMS 12"10"HEEL HT.1/2" GYP. SHEATHING ON GARAGE WALLS5/8" TYPE 'X' GYP. BD. ON GARAGE CEILS. 18" FLOOR TRUSSES9'-1 1/8"T.O. SUBFLR. T.O. PLATE TRUSSES @ 24" O.C. (DESIGNED BY MFR) 6 12 R-49 INSUL.9'-4"GARAGE 4" SLOPED CONC. W/ REBAR PERENGINEERS REPORT 9'-4" POURED WALL DRAIN TILE 10" POURED WALL R-5 INSUL. ATINTERIOR FOUND.9'-9 1/8"O. BATH OWNERS BDRM. 20x8 CONC. FTG.16x8 CONC. FTG. 16x8 CONC. FTG. SPRAY FOAM RIM 8'-2" +/-FOUND. HELD IN 2" FOR INSULATION TYP. NOTE: (INSUL. FLUSH w/ SHTG.) CANT. 2x8 SILL PLT. 1-1/2"3 1/2" CONC. FLOOR 8 1/4"6"HEEL HT.6 12 3.5 12 8"HEEL HT.FUT. BDRM. #5 R.I. BATH 8 1/4"8'-0"7'-9"NOTE: TOP HUNG TRUSSES AT FRONT OF HOME (9'-4" H. FDN. WALL) SPRAY FOAM RIM 4"12"6 3/4" +/-1'-8 1/4"20x8 CONC. FTG. T.O. FOUND.8'-4"R-5 THERMAX AT INTERIOR FOUND. AS REQUIRED 6 9 07-00-BUYERPROJECT # BUYER S/O BUYER S/O REVISIONS: STARTED: AGENT:X XLOT 5, BLOCK 8, SUMMERS CREEK17960 GRESFORD LN., LAKEVILLE, MN"RICHMOND" 1640 VILLA HOMEMARK ELLIOTT HOMES7-20-2020 PERMIT 8-4-2020 REV. #1 8-28-2020 REV. #2 OF SHEET SCALE: 3/16" = 1'-0" SECTION1 6 N.T.S. PORTAL FRAME DETAIL2 6 N.T.S. RADON DETAIL3 6 SIMPSON STRONG TIE Ab46z HEADER HURRICANE CLIP ATTACHED TO COLUMN & BEAM 11 7/8" OSB STRINGER W/ 2X4 BRACING 10 1/2" BULLNOSE LSL TREAD1X8 PINE S4S RISER NOTE: MAX RISE= 7 3/4"MIN. RUN= 10" 6'-8" CLEAR HEADROOM BATH BEDROOM #2 / OFFICEGREAT RM. 3/4" T & G FLOOR NOTE: SUBFLOOR JOINTS SHALL BESTAGGERED FROM FLOOR TRUSS ORJOIST JOINTS ALUM. SOFFIT & FASCIA 8" AGGREGATE6 MIL POLY. LAP SEAMS 12" 18" FLOOR TRUSSES9'-1 1/8"T.O. SUBFLR. T.O. PLATE TRUSSES @ 24" O.C. (DESIGNED BY MFR) R-49 INSUL.9'-4"W/ REBAR PERENGINEERS REPORT 9'-4" POURED WALL DRAIN TILE 10" POURED WALL R-5 INSUL. ATINTERIOR FOUND. 20x8 CONC. FTG.16x8 CONC. FTG. SPRAY FOAM RIM 8'-2" +/-FOUND. HELD IN 2" FOR INSULATION TYP. NOTE: (INSUL. FLUSH w/ SHTG.) CANT. 2x8 SILL PLT. 1-1/2" 3 1/2" CONC. FLOOR 2" RIGID INSULATIONR-10 w/ WATCHDOG WATERPROOF COATING AROUND HOUSE FOUND. PORCH TAPEREDLP COLUMN10"HEEL HT.6 12 MECH. / STORAGEFUT. FAMILY ROOM 6 12 KITCHEN 8 1/4"4x4 TRTD. COL. 2x OVER 10" TRIM 3 5 GIRDER 1'-6" 1'-2" 4" LEDGE NOTE: TOP HUNG TRUSSES AT FRONT OF HOME (9'-4" H. FDN. WALL) CONC. STOOP6 3/4" +/-4"SPRAY FOAM RIM1'-8 1/4"20x8 CONC. FTG. T.O. FOUND.8'-4"2 5 R-5 THERMAX AT INTERIOR FOUND. AS REQUIRED 16RUNEXCAVATED SOIL ALL SLABS WILL HAVE A MIN. 4" CLEAN AGGREGATE, COVERED BY6 MIL POLY. THIS POLY WILL HAVE 12" LAP AT ALL SEAMS. ALL TEARS ORPUNCTURES WILL BE SEALED OR COVERED BY POLY. ALL OPENINGS WILL BESEALED USING POLYURETHANE CAULK OR ELASTOMERIC SEALANT AT ALL OPNGS. AN INSTALLED 3" GASTIGHT PVC PIPE WILL BE CONNECTED TO THE DRAINTILE SYSTEM. A "T" FITTING WILL BE INSTALLED WITH 10 L.F. EACH ENDOF THE "T", OF PERFORATED PIPE, INTO THE DRAIN TILE SYSTEM. THE SHORTEST ROUTE WILL BE USED TO EXIT THE ROOF SYSTEM, WITH A MAX. OF 2 90DEGREE ELBOWS. IN UNCONDITIONED AREAS, THE RADON EXHAUST PIPE WILLBE INSULATED WITH AN R4 SLEEVE. THIS PIPE WILL BE LABELED "PASSIVERADON" AT ALL ACCESSIBLE LOCATIONS. AT ROOF EXIT LOCATIONS, MAINTAIN A 10' DISTANCE TO ANY WINDOWLOCATION, 2' BELOW EXHAUST POINT AND ANY ADJACENT STRUCTURE. THELOCATION OF THE EXIT POINT, IN TRUSS AREA, WILL BE CLEAR OF ANYOBSTRUCTIONS WITHIN 24" HORIZONTALLY AND 36" VERTICALLY. INSTALL AN OUTLET AND PULL CHORD LIGHT FOR FUTURE EXHAUST FANADDITION. SIMPSON STHD14 HOLD DOWN SIMPSON LSTA36 STRAP ON INSIDE FACE OF WALL 5/8" ANCHOR BOLT 1/2" OSB SHEATHING HEADER- SEE PLAN FOR SIZE FASTEN SHEATHING TO HEADER WITH 8d COMMON ORGALVANIZED BOX NAILS IN 3" GRID PATTERN ASSHOWN, AND 3" O.C. IN ALL FRAMING MEMBERS TYP. SHEATHING SPLICE (IF NEEDED) MUST BELOCATED WITH-IN 24" OF THE MID HEIGHTOF THE DOOR OPENING. PROVIDE 2-2X6BLOCKING BEHIND SPLICE FASTEN TOP PLATE TO HEADER WITH2 ROWS OF 16d SINKER NAILS 3" O.C. BLOCK BACK SIDE OF HEADER FLUSH WITH STUDSAT STRAP LOCATIONS 7 9 07-00-BUYERPROJECT # BUYER S/O BUYER S/O REVISIONS: STARTED: AGENT:X XLOT 5, BLOCK 8, SUMMERS CREEK17960 GRESFORD LN., LAKEVILLE, MN"RICHMOND" 1640 VILLA HOMEMARK ELLIOTT HOMES7-20-2020 PERMIT 8-4-2020 REV. #1 8-28-2020 REV. #2 OF SHEET SCALE: 1/8" = 1'-0" ROOF PLAN1 7SADDLE NOTE: SEE ROOF TRUSS LAYOUT FOR TRUSS DIRECTION AND GIRDER LOCATIONS PROVIDED BY MANUFACTURER PROVIDE ATTIC VENTILATION EQUAL TO 1/150th ATTIC AREA. IF 50% OR MORE IS PROVIDED IN UPPER PORTION OF THE ROOF AND REMAINDER IS PROVIDED IN SOFFIT VENTS, IT MAY BE REDUCED TO 1/300th ATTIC AREA. ICE AND WATER SHIELD 6'-0" IN FROM EAVES 1'-6" ON EACH SIDE OF VALLEY WHERE WALLS MEET ROOF ICE & WATER SHIELD SHOULD RUN UP WALL 1'-6" AND OUT FROM WALL 1'-6" NOTE: NOTE: NOTE: 8" 1'-0"2'-0"12:12RIDGERIDGE 1'-0"1'-0"1'-6"6:126:123:126:1212:12 2'-0"2'-6"8"10'-0"1'-6"1'-6"1'-0"12:1212:12 1'-6"1'-6" 12:12 12:12 8 9 07-00-BUYERPROJECT # BUYER S/O BUYER S/O REVISIONS: STARTED: AGENT:X XLOT 5, BLOCK 8, SUMMERS CREEK17960 GRESFORD LN., LAKEVILLE, MN"RICHMOND" 1640 VILLA HOMEMARK ELLIOTT HOMES7-20-2020 PERMIT 8-4-2020 REV. #1 8-28-2020 REV. #2 OF SHEET MAIN FLR. ELECTRICAL PLAN SCALE: 1/8" = 1'-0" LOWER LEVEL ELECTRICAL PLAN SCALE: 1/8" = 1'-0" DUPLEX CONVENIENCE OUTLET DUPLEX OUTLET ABOVE COUNTER WEATHERPROOF DUPLEX OUTLET HALF-SWITCHED DUPLEX OUTLET DUPLEX OUTLET IN FLOOR 220 VOLT OUTLET WALL SWITCH THREE-WAY SWITCH FOUR-WAY SWITCH CEILING MOUNTED INCANDESCENT LIGHT FIXTURE WALL MOUNTED INCANDESCENT LIGHT FIXTURE RECESSED INCANDESCENT LIGHT FIXTURE LIGHT FIXTURE WITH PULL CHAIN TRACK LIGHT FLOURESCENT LIGHT FIXTURE EXHAUST FAN EXHAUST FAN/LIGHT COMBINATION CHIMES (OPTIONAL) SMOKE DETECTOR TELEPHONE (OPTIONAL) TELEVISION (OPTIONAL) THERMOSTAT ELECTRIC METER ELECTRIC PANEL SPEAKER (OPTIONAL) TV T M CH SD P.C. S S S 4 3 W.P. ELECTRICAL KEY DUPLEX OUTLET (GROUND FAULT PROTECTED)G.F.I.P. RECESSED INCANDESCENT EYE BALL FIXTURE CARBON MONOXIDE DETECTORCM GARAGE DOOR OPENER OUTLETGDO FLUORESCENT LIGHT PER SPEC FAN/LIGHT COMBO PREWIRE, PROVIDE ADEQUATE SUPPORT 4 BULB FIXTURE 3 BULB FIXTURE 200 AMP SERVICE LIGHTING PACKAGE: T.B.D. LINE TO DRYER: T.B.D.SSTVABV. FP.NOTE:TECH TUBE TV W.P.RGH.-IN FAN G.F.I.P.S3S3OPT. LTS.PENDANT 3SS C/L 7'-6"3'-2"4'-9 1/2"TV SD SD GDO G.F.I.P.SG.F.I.P.G.F.I.P.G.F.I.P. W.P.SS S 3S SSDISP SS TO LIGHT RGH.-IN FANOPT. SS G.F.I.P.DW GAS RANGEMICRO ABV.LNDRY. DRYER WASHER(VENT TO OUTSIDE)REF. KITCHEN GREAT ROOM FOYER PORCH O. BATH GARAGE O. CLST BEDROOM #2 / OFFICE OWNERS BDRM. SMOKECM / ATTICACCESSMUDRM. OPT. PORCH DINING 12'x10' DECK OPT. 15'X10' EXP. DECK SMOKECM / SS S4S3S4S SS SS G.F.I.P.S3 S3 S3SS PANTRY BATHG.F.I.P.EXCH.AIRFURN F.D. WH SMOKECM / S S3S TO LIGHT A/C UNIT w/ BRACKET G.F.I.P.G.F.I.P.MECH. / STORAGE WS FUT. BDRM. #5 FUT. FAMILY ROOM R.I. BATH SUMP H20OPT. 3 9 9 07-00-BUYERPROJECT # BUYER S/O BUYER S/O REVISIONS: STARTED: AGENT:X XLOT 5, BLOCK 8, SUMMERS CREEK17960 GRESFORD LN., LAKEVILLE, MN"RICHMOND" 1640 VILLA HOMEMARK ELLIOTT HOMES7-20-2020 PERMIT 8-4-2020 REV. #1 8-28-2020 REV. #2 OF SHEET SPACE WASH. LNDRY. ELEV. SCALE: 3/8"=1'-0" DRYER SPACE30"CROWN MOULDING 9 8 C'TOP RAISED w/ FRONT LOAD W&D 3'-5"2'-11 1/4"3'-0"7'-0"WALL MOUNT 7'-6" O. BATH ELEV. 9 7 SCALE: 3/8"=1'-0" 3'-0"1'-6"3'-0" MARBLE C'TOP.WHITE CULT. NOTE: OPT. MIRROR MARBLE C'TOP.WHITE CULT. NOTE: 5 OPT. BUILT-INS @ DINING ELEV. 9 SCALE: 3/8"=1'-0" GRANITE TOP w/ OPT. BUILT-INS 18" D. 1'-9"1'-9"3'-0" 5'-0"FILLERFILLER2'-11 1/4"3'-0"7'-0"MIRROR WALL MOUNT 2'-6" BATH ELEV. SCALE: 3/8"=1'-0"9 63'-0"49" +/-NO HEARTH PER SPECS 12" SURROUND @ FRONT ONLY 42" W. GAS F.P.R.O. 42"x38 1/4" x 16 1/4" GATHERING RM. F.P. ELEV. 9 1 SCALE: 3/8"=1'-0" MANTLE PER SPECS 3'-0"3'-0" 5'-0" 4 KITCHEN ELEV. 9 SCALE: 3/8"=1'-0" 67" FIN. 2 KITCHEN ELEV. 9 SCALE: 3/8"=1'-0" 4'-6" REFRIG. SPACE2'-0"3'-0" 24" DEEP CROWN MLDG END PANEL 4'-6" 3 KITCHEN ELEV. 9 SCALE: 3/8"=1'-0" (SHTRCK. @ SIDES) 60" TV (REF. ONLY) 3'-8 1/2"2'-0"3'-0"2'-0" 12'-6" D.W. SPACE SINK 2'-0"1'-6" CROWN 3'-0"1'-6" MLDG 2'-0"1'-6" OPT. BUILT-INS 3'-0"7'-9" OPT. BUILT-INS 3'-8 1/4" 2'-6" 15" D. MICRO RANGE SPACE (VENT TO OUTSIDE) 1'-6" 2 KITCHEN ELEV. 9 SCALE: 3/8"=1'-0" 2'-0" REFRIG. SPACE2'-0"3'-0" 24" DEEP CROWN MLDG END PANEL 2'-0" 3 KITCHEN ELEV. 9 SCALE: 3/8"=1'-0" 3'-0"2'-0" 12'-6" D.W. SPACE SINK 2'-0"1'-6" CROWN 3'-0"1'-6" MLDG 1'-6"3'-0"7'-9 1/2" 2'-6" 15" D. (VENT TO OUTSIDE) 1'-6" COOKTOP HOOD VENT OVEN / MICRO BW 07-00-BUYERPROJECT # BUYER S/O BUYER S/O REVISIONS: STARTED: AGENT:X XLOT 5, BLOCK 8, SUMMERS CREEK17960 GRESFORD LN., LAKEVILLE, MN"RICHMOND" 1640 VILLA HOMEMARK ELLIOTT HOMES7-20-2020 PERMIT 8-4-2020 REV. #1 8-28-2020 REV. #2 N.T.S. MAIN LEVEL BRACEWALL2 BW N.T.S. BRACEWALL DETAILS3 BW MIN. 3''x11 1/4'' NET HEADER(STEEL HDR. PROHIBITED) EXTENT OF HEADER W/ SINGLE PORTAL FRAME ONE BRACED WALL PANEL 10'-0'' MAX. HEIGHT(TOP OF HDR.)TOP OF FDN.TOP OF CONC FLOOR AT OPENING MIN. 2-2x4 FRAMING STUD POST CONTINUOUS HEADER WITH DOUBLE PORTAL FRAMES TWO BRACED WALL PANELS 6' TO 18' OPENING FASTEN TOP PLATE TO HEADER W/ 2ROWS OF 16d SINKER NAILS @ 3'' O.C. TYP. 1000 LB. STRAP OPPOSITE SIDE OF SHEATHING FASTEN SHEATHING TO HEADER W/ 8dCOMMON OR GALV. BOX NAILS IN 3'' GRIDPATTERN SHOWN AND 3'' O.C. IN ALLFRAMING(STUDS, BLOCK'G AND SILLS)TYP. MIN. WIDTH PER TABLE R602.10.5 3/8'' MIN. WOOD STRUCTURAL PANEL SHEATH'G. MIN. 2-2x4 MIN. 4200 LB. TIE DOWN DEVICE(EMBED INTOFOUNDATION AND NAILED INTO FRAMING MIN. (2) 1/2'' DIA. ANCHOR BOLT INSTALLED PER R403.1.6 W SEE LEFT FORTYP. PORTALFRAME CONST. FOR A PANEL SPLICE(IF NEEDED) PANELEDGES SHALL BEBLOCKED AND OCCURWITHIN 24'' OF MID-HEIGHT. ONE ROW OFTYP. SHEATH'G. TOFRAMING NAILING ISREQUIRED.IF 2x4 BLOCK'G. IS USEDTHE 2x4'S MUST BE NAILEDTOGETHER W/ 3 16dSINKER NAILS W/ 2''x2''x3/16'' PLATE WASHER12'-0'' MAX. HEIGHT(TOP OF WALL)FULL HEIGHT OF WALL - SEE TO RIGHT FOR SPLICESPONY WALL HT.EXTENT OF HEADER TENSION STRAP PERTABLE R602.10.6.4 (ONOPPOSITE SIDE OFSHEATHING ANCHOR BOLTSPER SECTIONR403.1.6 BRACED WALL LINECONTINUOUSLYSHEATHED WITHWOOD STRUCTURALPANELS TOP OF FLOOR AT OPENING FLOOR FRAMING ASSEMBLY PER PLAN W/ WOOD STRUCTURAL PANEL SHEATHING TOP OF FLOOR AT OPENING FLOOR FRAMING ASSEMBLY PER PLAN WOOD STRUCTURAL PANEL SHEATHINGTO TOP OF BAND OR RIM JOIST NAIL SOLE PLATE TO FLRFRAMING PERTABLE R602.3(1) (2) FRAMING ANCHORS APPLIED ACROSSSHEATHING JOINT WITH A CAPACITY OF670# IN HORIZ. AND VERT. DIRECTIONS SEE LEFT FORTYP. PORTALFRAME CONST. ON CONCRETE FOUNDATION ON RAISED WOOD FLOOR - FRAMING ANCHOR OPTION TOP OF FLOOR AT OPENING FLOOR FRAMING ASSEMBLY PER PLAN W/ WOOD STRUCTURAL PANEL SHEATHING TOP OF FLOOR AT OPENING FLOOR FRAMING ASSEMBLY PER PLAN WOOD STRUCTURAL PANEL SHEATHINGTO TOP OF BAND OR RIM JOIST NAIL SOLE PLATE TO FLRFRAMING PERTABLE R602.3(1) SEE LEFT FORTYP. PORTALFRAME CONST. ON RAISED WOOD FLOOR - OVERLAP FLOOR OPTION MIN. OVERLAP 9 1/4''WOOD STRUCTURAL PANEL SHEATHINGCONTINUOUS OVER BAND OR RIM JOIST MIN. OVERLAP 9 1/4''ATTACH TO RIM/BAND JOIST W/ 8dCOMMON NAILS AT 3'' O.C. AS SHOWN DBL TOP PLATE BOTTOM PLATE STUDS AT 16'' O.C.W/ 6d NAILS @ 6'' O.C. 4'-0"8'-0'' MIN., SEE PLANINTERMEDIATE 6''3"W/ 6d NAILS @ 3'' O.C.EDGES NAILED LNDRY.KITCHEN GREAT ROOM FOYER PORCH O. BATH GARAGE O. CLST BEDROOM #2 / OFFICE OWNERS BDRM.ATTICACCESSMUDRM. DINING 12'x10' DECK GARAGE PORTAL FRAMING PER BUILDING CODE IRC R602.10.6.4 BRACED WALL METHOD CS-WSP4'-0" PANELBRACED WALLLINE 1BRACED WALLLINE ABRACED WALLLINE 23'-5" PANEL 6'-0" GYP. PANEL BRACED WALLLINE B BRACED WALLLINE C 3'-5" PANEL 3'-2" PANEL3'-2" PANEL 3'-5" PANEL 4'-0" PANEL4'-0" PANEL4'-0" PANEL4'-0" PANEL4'-0" PANEL4'-0" PANEL4'-0" PANEL4'-0" PANEL8'-0" GYP. PANEL 8'-0" GYP. PANEL 3'-3" PANEL 4'-5" PANEL 1'-4" PANEL PANTRY BATH Created by BAM version 052009 New Construction Energy Code Compliance Certificate Place your logo here Per N1101.8 Building Certificate. A building certificate shall be posted in a permanently visible location inside the building. The certificate shall be completed by the builder and shall list information and values of components listed in Table N1101.8. Date Certificate Posted Mailing Address of the Dwelling or Dwelling Unit City 17960 Gresford Lane Lakeville Name of Residential Contractor MN License Number Mark Elliot Homes PM64995 THERMAL ENVELOPE RADON SYSTEM Insulation Location Total R-Value of all Types ofInsulationType: Check All That Apply X Passive (No Fan)Non or Not ApplicableFiberglass, BlownFiberglass, BattsFoam, Closed CellFoam Open CellMineral FiberboardRigid, Extruded PolystyreneRigid, IsocynurateActive (With fan and monometer or other system monitoring device) Other Please Describe Here Below Entire Slab Foundation Wall R-15 x Exterior 2" CertiStud -- Interior 3/4" Thermax Perimeter of Slab on Grade R-10 x Rim Joist (Foundation)N/A Rim Joist (1st Floor+)N/A Interior Wall R-21 x Ceiling, flat R-49 x Attic Ceiling, vaulted R-38 x Bay Windows or cantilevered areas N/A Interior Bonus room over garage N/A Exterior & Interior Describe other insulated areas Windows & Doors Heating or Cooling Ducts Outside Conditioned Spaces Average U-Factor (excludes skylights and one door) U: 0.29 X Not applicable, all ducts located in conditioned space Solar Heat Gain Coefficient (SHGC):0.28 R-value MECHANICAL SYSTEMS Make-up Air Select a Type Appliances Heating System Domestic Water Heater Cooling System X Not required per mech. code Fuel Type Natural Gas Natural Gas Electric Passive Manufacturer Bryant Bradford White Bryant Powered Model 912S MITW50 113A Interlocked with exhaust device. Describe: Rating or Size Input in BTUS:42973 Capacity in Gallons: 50 Output in Tons:2 X RenewAire Exchanger EV130 Structure's Calculated Heat Loss: Heat Gain:19,737 Basement and Duct in Floor trusses Efficiency AFUE or HSPF% 92.00% SEER: 13 Calculated cooling load: 19,737 Cfm's " round duct OR Mechanical Ventilation System " metal duct Combustion Air Select a Type Not required per mech. code Select Type X Passive Heat Recover Ventilator (HRV) Capacity in cfms:Low: Variable High:Other, describe: x Energy Recover Ventilator (ERV) Capacity in cfms:58 Speed High:115 Location of duct or system: Continuous exhausting fan(s) rated capacity in cfms:6 " 0 Location of fan(s), describe: Mechanical room in Garage Cfm's Capacity continuous ventilation rate in cfms:115/58 CFM X " round duct OR Total ventilation (intermittent + continuous) rate in cfms:50%=63CFM " metal duct NEW RESIDENTIAL CONSTRUCTION SWPPP VERIFICATION This form must be completed and submitted with all new residential permit applications. A National Pollutant Discharge Elimination System (NPDES) Construction Stormwater Permit is required for “Construction activity that results in land disturbance of equal to or greater than one (1) acre or if a project is part of a common plan of development that will ultimately disturb greater than one (1) acre,” (NPDES Permit, Section 1.2). Project Site Address: _____________________________________________________________________ Company Name: _________________________________________________________________________ *Primary Company Contact: _________________________________________________________________ *Should a site be deemed noncompliant, this individual will be notified Phone #: ____________________________ Email: ______________________________________________ If you are not covered under a NPDES Construction Stormwater Permit administered by the Minnesota Pollution Control Agency (MPCA), an erosion and sediment control plan MUST be approved as part of the residential building permit application. “Permittees must ensure a trained person will inspect the entire construction site at least once every seven (7) days during active construction and within 24 hours after a rainfall event greater than ½ inch in 24 hours,” (NPDES Permit, Section 11.2). The City of Lakeville reserves the right to request weekly inspection logs. The City of Lakeville may issue a STOP WORK ORDER; withhold building inspections; or, draw on securities/escrows to bring the site into compliance with the NPDES Construction Stormwater Permit (MN R 100001) or erosion and sediment control plan. Contact information of person CERTIFIED to provide weekly onsite erosion and sediment control inspections and corrective actions: Name: ____________________________________ Company: ___________________________________ Phone # (24 hr Contact): ______________________ Email: ______________________________________ Entity that Provided Training: __________________________ Certification Expiration Date: ____________ NOTE: Prior to any land-disturbing activity, all erosion and sediment controls must be installed I understand the above information to be accurate and I have read, understood, and accepted all terms and conditions of the NPDES Permit (MN R 100001). Signature: ________________________________________________ Date:_________________________ Contact the City of Lakeville with questions at erosion@lakevillemn.gov or 952-985-4500 X9/9/2020 DJM