Loading...
HomeMy WebLinkAboutLA184913 9970 192nd St W Permit PackRESIDENTIAL BUILDING PERMIT APPLICATION PAGE 2 OFFICE USE ONLY BUILDING PERMIT TYPE REQUIRED INSPECTIONS SINGLE FAMILY DWELLING BUILDING DUPLEX AS BUILT TOWNHOUSE UNITS BUILDING FINAL DETACHED TOWN HOUSE UNIT DECK FOOTING CONDO FIREPLACE ACESSORY BUILDING FOOTING REROOF FOUNDATION RESIDE FRAMING PORCH FRAMING GARAGES INSULATION RES ADDN/REPAIR/RMDL DECK PORCH GARAGES LATH LOWER LEVEL FINISH LOWER LEVEL FINAL ADDITION OTHER FOUNDATION ONLY PORCH FOOTING MISCELLANEOUS POURED WALL DEMO SEPTIC TANK REMOVAL MOVED SITE MECHANICAL CITY BUILDING VALUATION: $AIR TEST FINAL BUILDING PERMIT FEES ROUGH-IN $PERMIT FEE PLUMBING $PLAN CHECK FINAL $SURCHARGE ROUGH-IN $METRO SAC METER SIZE $CITY WATER HOOKUP UNIT PRESSURE REDUCING VALVE $CITY SEWER HOOKUP UNIT SEWER/WATER $LANDSCAPE ESCROW SEWER/WATER $TREE ESCROW FINAL $MISC ESCROW STREET DRAINTILE $PLUMBING BUILDING INFORMATION $MECHANICAL TYPE OF CONSTRUCTION $SEWER WATER ZONING $OTHER CODE EDITION $TOTAL FIRE SUPPRESSION SYSTEM OCCUPANCY GROUP APPROVED BY: BUILDING INSPECTOR: Date: PLUMBING/MECHANICAL INSPECTOR: Date: COMMENTS: 20195 Holyoke Avenue, Lakeville, MN 55044 952-985-4400  952-985-4499 fax www.lakevillemn.gov Sewer & Water Tie Card Address:________________________________________ Contractor:______________________________________ Permit Number:__________________________________ Final Date:________________ Street Drain-Tile:______ Size of Water Service: 1” Comments: AIRTEST SANITARY OVER 20’/2 FITTINGS THIS CARD MUST BE COMPLETED AND ON-SITE AT TIME OF SEWER & WATER INSPECTION Concept Approval ONLYSubject to Field InspectionInspectorDate2020MN BldgCode10/06/2020dmathews Beam must be let in tohouse and bear onfoundation, cannot hangdeck beams from ledger.Interior BWP AboveUFER Ground-Provide 20' Rebar in footing and stubup near electrical service panel.33"x33"x8" FANFANFANSmokeSmokeSmokeCOSmokeCOCS-PFCS-PFCS-PFCS-PFTemper glasswithin 2' of door-Min. 15" clearance to anyobstruction from center ofW.C., 24" in front(typ).(2)14" LVL(2)14" LVL ALIGN Structural, Inc. 241 CLEVELAND AVENUE SOUTH SAINT PAUL, MINNESOTA 55105-1255 t 651.698.0164 | f 651.698.0165 ______________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________ Phillips Planning, Inc. September 14, 2020 13754 Frontier Court, Suite 100 Burnsville, MN 55337 Attn: Aaron Winchell Re: Isenmann Residence-Foundation Design 9970 192nd Street W Lakeville, MN 55044 Project #20263 Mr. Winchell, Let it be known that our firm has provided structural design and directed the drafting of structural conditions for the following elements of the referenced project: 1. Precast plank connections to the foundation walls at the Lower Garage/Upper Garage 2. Foundation walls supporting precast plank 3. Footings at foundation walls supporting precast plank 4. Lintels at openings in foundation walls leading into the Lower Garage (2 openings thus) The latest set of construction documents showing this design includes Sheets 1-5 prepared by Phillips Planning, Inc., dated September 14, 2020. Please contact our office with any questions or comments regarding the structural conditions in Items 1-4 above. Note that our firm shall not be considered “Engineer of Record” for the project. Respectfully Submitted, Richard W. Johnson, PE, Principal Minnesota Registration #23406 Dave And Brigid Isenmann Residence HVAC Load Calculations for Isenmann Construction Inc. 20967 Huntsville Trail Lakeville, MN 55044 Prepared By: Jake Ryan Silver Tree Plumbing & Heating 1335 Mendota Heights Rd Mendota Heights, MN 55120 651-900-7053 Thursday, September 3, 2020 Rhvac is an ACCA approved Manual J, D and S computer program. Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D. Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Silver Tree Plumbing & Heating Dave And Brigid Isenmann Residence Eagan, MN 55121 Page 2 Project Report General Project Information Project Title:Dave And Brigid Isenmann Residence Designed By:Jake Ryan Project Date:9/3/2020 Project Comment: Client Name:Isenmann Construction Inc. Client Address:20967 Huntsville Trail Client City:Lakeville, MN 55044 Client Phone:(651) 983-7449 Company Name:Silver Tree Plumbing & Heating Company Representative:Jake Ryan Company Address:1335 Mendota Heights Rd Company City:Mendota Heights, MN 55120 Company Phone:651-900-7053 Company E-Mail Address:jaker@silvertreepandh.com Design Data Reference City:Minneapolis, Minnesota Building Orientation:Front door faces North Daily Temperature Range:Medium Latitude:44 Degrees Elevation:834 ft. Altitude Factor:0.970 Outdoor Outdoor Outdoor Indoor Indoor Grains Dry Bulb Wet Bulb Rel.Hum Rel.Hum Dry Bulb Difference Winter:-15 -15.33 n/a n/a 72 n/a Summer:88 73 50%50%72 42 Check Figures Total Building Supply CFM:1,108 CFM Per Square ft.:0.267 Square ft. of Room Area:4,150 Square ft. Per Ton:1,585 Volume (ft³):37,346 Building Loads Total Heating Required Including Ventilation Air:49,484 Btuh 49.484 MBH Total Sensible Gain:24,621 Btuh 78 % Total Latent Gain:6,787 Btuh 22 % Total Cooling Required Including Ventilation Air:31,408 Btuh 2.62 Tons (Based On Sensible + Latent) Notes Rhvac is an ACCA approved Manual J, D and S computer program. Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at your design conditions. F:\ ...\Dave and Brigid Isenmann - Heat Calc.rh9 Thursday, September 3, 2020, 1:40 PM Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Silver Tree Plumbing & Heating Dave And Brigid Isenmann Residence Eagan, MN 55121 Page 3 Load Preview Report Scope Has AED Net Ton ft.² /Ton Area Sen Gain Lat Gain Net Gain Sen Loss Min Htg CFM Min Clg CFM Sys Htg CFM Sys Clg CFM Sys Act CFM Duct Size Building 2.62 1,585 4,150 24,621 6,787 31,408 49,484 582 1,108 582 1,108 1,108 System 1 Main Floor Yes 2.62 1,585 4,150 24,621 6,787 31,408 49,484 582 1,108 582 1,108 1,108 12x17 Ventilation 981 4,781 5,762 5,978 Zone 1 4,150 23,641 2,006 25,647 43,506 582 1,108 582 1,108 1,108 12x17 1-Basement 2,075 6,730 0 6,730 19,600 262 315 262 315 315 3--6 2-Main Level 2,075 16,911 2,006 18,917 23,906 320 792 320 792 792 7--6 F:\ ...\Dave and Brigid Isenmann - Heat Calc.rh9 Thursday, September 3, 2020, 1:40 PM Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Silver Tree Plumbing & Heating Dave And Brigid Isenmann Residence Eagan, MN 55121 Page 4 Duct Size Preview Room or Duct Name Source Minimum Velocity Maximum Velocity Rough. Factor Design L/100 SP Loss Duct Velocity Duct Length Htg Flow Clg Flow Act. Flow Duct Size System 1 Supply Runouts Zone 1 1-Basement Built-In 450 750 0.01 0.1 535.2 262 315 315 3--6 2-Main Level Built-In 450 750 0.01 0.1 576.4 320 792 792 7--6 Other Ducts in System 1 Supply Main Trunk Built-In 650 900 0.003 0.1 781.8 582 1,108 1,108 12x17 SummarySummarySummarySummarySummarySummarySummarySummary System 1 Heating Flow:582 Cooling Flow:1108 F:\ ...\Dave and Brigid Isenmann - Heat Calc.rh9 Thursday, September 3, 2020, 1:40 PM Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Silver Tree Plumbing & Heating Dave And Brigid Isenmann Residence Eagan, MN 55121 Page 5 Total Building Summary Loads Component Description Area Quan Sen Loss Lat Gain Sen Gain Total Gain LOWEE BUILDER GRADE: Glazing-LOWEE BUILDER GRADE, ground reflectance = 0.23, indoor insect screen with 100% coverage, U-value 0.32, SHGC 0.32 533.1 14,840 0 11,608 11,608 11J: Door-Metal - Fiberglass Core, U-value 0.6 40 2,088 0 648 648 12F-0sw: Wall-Frame, R-21 insulation in 2 x 6 stud cavity, no board insulation, siding finish, wood studs, U-value 0.065 2066.8 11,688 0 2,191 2,191 15B0-10sf-8: Wall-Basement, , R-10 board insulation to floor, no interior finish, 8' floor depth, U-value 0.05 1336.5 6,237 0 151 151 RJ R-20 RIM JOIST: Wall-Frame, Custom, RJ R-20 RIM JOIST R-20 SPRAY FOAM, U-value 0.05 329.2 1,433 0 337 337 R49 Attic: Roof/Ceiling-Under Attic with Insulation on Attic Floor (also use for Knee Walls and Partition Ceilings), Custom, R-49 Blown insulation in attic, U- value 0.02 2074.8 3,610 0 2,116 2,116 21A-32: Floor-Basement, Concrete slab, any thickness, 2 or more feet below grade, no insulation below floor, any floor cover, shortest side of floor slab is 32' wide, U-value 0.02 2074.8 3,610 0 0 0 Subtotals for structure:43,506 0 17,051 17,051 People:6 1,200 1,380 2,580 Equipment:806 3,334 4,140 Lighting:550 1,876 1,876 Ductwork:0 0 0 0 Infiltration: Winter CFM: 0, Summer CFM: 0 0 0 0 0 Ventilation: Winter CFM: 174, Summer CFM: 174 5,978 4,781 981 5,762 Total Building Load Totals:49,484 6,787 24,621 31,408 Check Figures Total Building Supply CFM:1,108 CFM Per Square ft.:0.267 Square ft. of Room Area:4,150 Square ft. Per Ton:1,585 Volume (ft³):37,346 Building Loads Total Heating Required Including Ventilation Air:49,484 Btuh 49.484 MBH Total Sensible Gain:24,621 Btuh 78 % Total Latent Gain:6,787 Btuh 22 % Total Cooling Required Including Ventilation Air:31,408 Btuh 2.62 Tons (Based On Sensible + Latent) Notes Rhvac is an ACCA approved Manual J, D and S computer program. Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at your design conditions. F:\ ...\Dave and Brigid Isenmann - Heat Calc.rh9 Thursday, September 3, 2020, 1:40 PM Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Silver Tree Plumbing & Heating Dave And Brigid Isenmann Residence Eagan, MN 55121 Page 6 Building Rotation Report All rotation degree values in this report are clockwise with respect to the project's original orientation. Building orientation as entered (zero degrees rotation): Front door faces North Individual Rooms Rm. No. Room Name 0° Rot. CFM 45° Rot. CFM 90° Rot. CFM 135° Rot. CFM 180° Rot. CFM 225° Rot. CFM 270° Rot. CFM 315° Rot. CFM High Duct Size System 1: Zone 1: 1 Basement 315 386 *390 348 249 323 351 364 4--6 2 Main Level 792 952 *1,012 934 757 879 918 891 9--6 * Indicates highest CFM of all rotations. Whole Building Rotation Degrees Front door Faces Supply CFM Sensible Gain Latent Gain Net Tons 0°North 1,108 24,621 *6,787 2.62 45°Northeast 1,338 29,541 6,787 3.03 90°East *1,401 *30,892 6,787 *3.14 135°Southeast 1,282 28,351 6,787 2.93 180°South 1,006 22,463 6,787 2.44 225°Southwest 1,202 26,647 6,787 2.79 270°West 1,269 28,057 6,787 2.90 315°Northwest 1,255 27,761 6,787 2.88 * Indicates highest value of all rotations. 2.2 2.4 2.6 2.8 3.0 North Northeast East Southeast South Southwest West NorthwestCooling TonsDirection Front door Faces Building Rotation Tonnage Building Net Tonnage F:\ ...\Dave and Brigid Isenmann - Heat Calc.rh9 Thursday, September 3, 2020, 1:40 PM Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Silver Tree Plumbing & Heating Dave And Brigid Isenmann Residence Eagan, MN 55121 Page 7 Building Rotation Report (cont'd) 25,000 26,000 27,000 28,000 29,000 30,000 31,000 32,000 33,000 34,000 35,000 36,000 37,000 38,000 39,000 40,000 41,000 42,000 43,000 44,000 8 am 9 am 10 am 11 am 12 pm 1 pm 2 pm 3 pm 4 pm 5 pm 6 pm 7 pmBuilding Net Gain, BtuhTime of Day Building Rotation Hourly Net Gain Front door faces North Front door faces Northeast Front door faces East Front door faces Southeast Front door faces South Front door faces Southwest Front door faces West Front door faces Northwest F:\ ...\Dave and Brigid Isenmann - Heat Calc.rh9 Thursday, September 3, 2020, 1:40 PM Passive (No Fan) Active (With fan and monitoring device ) Location (or future location) of Fan: Other Please Describe Here Not applicable, all ducts located in conditioned space Not required per mech. code Passive Powered Interlocked with exhaust device. Describe: Input in BTUS: Capacity in Gallons: Other, describe: AFUE or HSPF% Cfm's " round duct OR " metal duct Not required per mech. code Passive Low: Other, describe: Low: Location of fan(s), describe: Cfm's " round duct OR " metal duct Per R401.3 Certificate. A building certificate shall be posted on or in the electrical distribution panel. New Construction Energy Code Compliance Certificate Name of Residential Contractor MN License Number City Mailing Address of the Dwelling or Dwelling Unit Rigid, Extruded PolystyreneHeat Recover Ventilator (HRV) Capacity in cfms: Energy Recover Ventilator (ERV) Capacity in cfms: Combustion Air Select a Type Location of duct or system: Rim Joist (2nd Floor+) Building envelope air tightness: Below Entire Slab Fuel Type Solar Heat Gain Coefficient (SHGC): Windows & Doors Ceiling, vaulted Bay Windows or cantilevered areas Floors over unconditioned area THERMAL ENVELOPE Foam Open Cell Wall Rigid, Isocynurate Perimeter of Slab on Grade RADON CONTROL SYSTEM Total R-Value of all Types of InsulationType: Check All That Apply Mineral FiberboardInsulation Location Foam, Closed Cell Describe other insulated areas Ceiling, flat Non or Not ApplicableFiberglass, BlownFiberglass, Batts Foundation Wall Output in Tons: Appliances Cooling System Location of duct or system: Heating or Cooling Ducts Outside Conditioned Spaces Make-up Air Select a Type Domestic Water Heater Model Heating System Rim Joist (1st Floor) Average U-Factor (excludes skylights and one door ) U: Duct system air tightness: Rating or Size Efficiency Heating Gain Cooling Load Select Type Describe any additional or combined heating or cooling systems if installed: (e.g. two furnaces or air source heat pump with gas back-up furnace): Residential Load Calculation SEER /EER Capacity continuous ventilation rate in cfms: Heating Loss Manufacturer Total ventilation (intermittent + continuous) rate in cfms: Balanced Ventilation capacity in cfms: High: High: MECHANICAL VENTILATION SYSTEM Date Cert. Posted R-value MECHANICAL SYSTEMS Builders Associaton of Minnesota version 101014 Reviewed 9/21/2020 AM DJM 9/24/20 X