Loading...
HomeMy WebLinkAbout19932 Henley Lane Survey(1056.5)(1063.6) x(1061.5)(1063.2)HENLEY LANE 11.0 030.3317.63 108.81OS 22.00HUB=1064.06OS 42.68HUB=1057.68OS 34.44HUB=1052.62OS 32.17HUB=1062.88FD I P FD IP R:1048.51 C.O.SERV R:1056.40 R:1056.72 GARA G E GAR A G E EXISTINGHOUSEUNDER CONST.EXISTINGHOUSE101010105 5 5 5 6.6%DRAINAGE &UTILITY EASEMENTEX. SODEX. SODFBW O PRO P O S E D HOU S E POR C H 1057 . 4 1056.8 1061. 6 106 4 . 1 106 4 . 4 1061.0105 5 . 91051.01059.2 106 4 . 3 1065 .3 105 7 . 7 105 1 . 1 1063.31062.11060.41056.01055.61056.41059.61061.61053.6 N67°55'57"W184.44195.96N72°41'46"W74.24 N06°07'20"E Δ=12°17'41"R=240.0051.50 Δ=6°18'41"R=330.0036.35 6.00 21.5 0 33.66 11. 6 7 4.00 9.6 6 14.17 20.5 0 2.00 11. 0 0 24.50 11. 1 7 17.33 10. 0 0 3.00 14.6 6 3.00 17. 0 0 S.W.(106 4 . 6 7 )(1064.1)(1062.9)(1057.7)(1056.5)(1053.0)(106 4 . 3 ) (1057 . 4 ) (1059.2) L.O.(1063.4)(1056.5)(1059.7)1058.01057.4(1052 . 3 )1052.2(1052.0)(1057.5)1063.91061.9TW: 963.0BW: 960.0(1059.7)1060.2(1064.3)(1051.0)EX. SOD1061.21062.0(1062.5)LOOKOUTDENOTES EXISTING CATCH BASINDENOTES EXISTING HYDRANTDENOTES EXISTING SANITARY MANHOLEDENOTES EXISTING STORM MANHOLEDENOTES EXISTING UTILITY BOXDENOTES EXISTING SERVICE OR CLEANOUTDENOTES IRON MONUMENT FOUNDDENOTES IRON MONUMENT SETDENOTES EXISTING POWER POLEDENOTES EXISTING LIGHT POLEDENOTES EXISTING CONSERVATION POSTOR WET LAND BUFFER POSTDENOTES EXISTING TREE8" TREE000.0DENOTES WOOD HUBDENOTES NAILDENOTES EXISTING RETAINING WALLDENOTES PROPOSED RETAINING WALLDENOTES EXISTING ELEVATIONDENOTES PROPOSED ELEVATIONDENOTES AS BUILT ELEVATION(000.0)000.0DENOTES EXISTING TREELINEDENOTES DIRECTION OF SURFACE DRAINAGEDENOTES EXISTING FENCELEGENDDENOTES EXISTING F.E.S.LOT AREA : 15,215 SQ. FT.HOUSE AREA : 1,888 SQ. FT.PORCH AREA : 168 SQ. FT.DRIVEWAY AREA : 896 SQ. FT.SIDEWALK AREA : 45 SQ. FT.TOTAL IMPERVIOUS AREA : 2,997 SQ. FT. (19.7%)CERTIFICATE OF SURVEYLegal Description:= FINISHED GARAGE FLOOR ELEVATION= BASEMENT FLOOR ELEVATION= TOP OF FOUNDATION ELEVATION(1064.67)(1065.00)(1057.00)1. No specific soils investigation has been performed on this lotby the surveyor. The suitability of the soils to support thespecific house is not the responsibility of the surveyor.2.No title information was provided for this survey. This surveydoes not purport to show all easements of record.3. See architectural plans for final building dimensions.BENCHMARK: TNH AT LOT 3 AND 4 BLOCK 1. ELEVATION=1075.82AREAS:NOTES 1. 1056.2 MINIMUM LOW FLOOR 2. DRAINTILE CONNECTION REQUIRED. 3.ROCK CONSTRUCTION ENTRANCE AT DRIVEWAY. 4. EROSION CONTROL AT GRADING LIMITS.Zoning = RS-3FY - 30'SY - 10' Interior, 20' CornerRY - 30'SY Buffer - 30'RY Buffer - 50'ENGINEERING REVIEWEDDate:__________________09/03/2020corlowskyEROSION CONTROLMUST BE INSTALLEDBEFORE EXCAVATION*Maintain 6" between bottom of siding and sod.*No structures in easements.The curb box, drain tile cleanout, and catchbasin(if applicable) must be inspected andaccepted before As-Built escrow monies willbe released. All structures must be flushwith the sod. This will be scheduled with thelandscape inspection.*Draintile connection required.