Loading...
HomeMy WebLinkAboutLA185271 -20554 Glade Ave Permit PackRESIDENTIAL BUILDING PERMIT APPLICATION PAGE 2 OFFICE USE ONLY BUILDING PERMIT TYPE REQUIRED INSPECTIONS SINGLE FAMILY DWELLING BUILDING DUPLEX AS BUILT TOWNHOUSE UNITS BUILDING FINAL DETACHED TOWN HOUSE UNIT DECK FOOTING CONDO FIREPLACE ACESSORY BUILDING FOOTING REROOF FOUNDATION RESIDE FRAMING PORCH FRAMING GARAGES INSULATION RES ADDN/REPAIR/RMDL DECK PORCH GARAGES LATH LOWER LEVEL FINISH LOWER LEVEL FINAL ADDITION OTHER FOUNDATION ONLY PORCH FOOTING MISCELLANEOUS POURED WALL DEMO SEPTIC TANK REMOVAL MOVED SITE MECHANICAL CITY BUILDING VALUATION: $AIR TEST FINAL BUILDING PERMIT FEES ROUGH-IN $PERMIT FEE PLUMBING $PLAN CHECK FINAL $SURCHARGE ROUGH-IN $METRO SAC METER SIZE $CITY WATER HOOKUP UNIT PRESSURE REDUCING VALVE $CITY SEWER HOOKUP UNIT SEWER/WATER $LANDSCAPE ESCROW SEWER/WATER $TREE ESCROW FINAL $MISC ESCROW STREET DRAINTILE $PLUMBING BUILDING INFORMATION $MECHANICAL TYPE OF CONSTRUCTION $SEWER WATER ZONING $OTHER CODE EDITION $TOTAL FIRE SUPPRESSION SYSTEM OCCUPANCY GROUP APPROVED BY: BUILDING INSPECTOR: Date: PLUMBING/MECHANICAL INSPECTOR: Date: COMMENTS: 20195 Holyoke Avenue, Lakeville, MN 55044 952-985-4400  952-985-4499 fax www.lakevillemn.gov Sewer & Water Tie Card Address:________________________________________ Contractor:______________________________________ Permit Number:__________________________________ Final Date:________________ Street Drain-Tile:______ Size of Water Service: 1” Comments: AIRTEST SANITARY OVER 20’/2 FITTINGS THIS CARD MUST BE COMPLETED AND ON-SITE AT TIME OF SEWER & WATER INSPECTION These plans, and the concept thereofor used without written consent. And may not be reproducedare the exclusive property of D.R. Horton Inc.,COPYRIGHT D.R. HORTON, INC. 2016CROOF PLAN1/8"=1'-0"REFSIDING LEGENDALAP SIDING "B" (COLOR 1)LAP SIDING "A" (COLOR 1)PRODUCTCBD5" TRIMNOT USEDAT FRONT ONLY1/2"=1'-0"TYPICAL WDW & DOOR TRIM3 1/2" TRIM 5" TRIM3 1/2" TRIM5" TRIM1.0X20860 KENBRIDGE COURT, SUITE 100LAKEVILLE, MN 55044 (952)985-72723035-C-3.3FINNEGANDRAWN: 5-14-2019-MGREVISED: 5-28-2019-MG SPEC HOMECUST:A D.R. HORTON COMPANYLIGHT FIXTURES1/2"=1'-0"BLOCKING AT7-1/4"12" 4"4" DIA. HOLEELEVATION CFINNEGAN 3035ICE & WATERALUMINUM FLASHINGBEHIND STOOP1xADDRESS NUMBERSTEEL PANEL OVERHEAD DOOR912XXXXXA6:12 PITCH6:12 PITCH1'-0"7 7/16"AA9129124:12 PITCHTYPICAL PORCH COLUMN:8x8 MFD COLUMN W/2x6 CAP & BASE AND4x4 ANGLED BRACESTEEL PANEL OVERHEAD DOOR2X6 CAP2X6 BASE8X8 REALWOOD COLUMN4X4 REALWOODANGLED BRACKET2X6 CAP2X6 BASE8X8 REALWOOD COLUMN4X4 REALWOODANGLED BRACKET1/2"=1'-0"PORCH COLUMN DETAIL6:12 PITCHPERMIT: 10-5-2020-CF 20554 GLADE AVENUE PERMIT/CONST.PLANSLOT 2, BLK 3, CEDAR CROSSINGSLEFT ELEVATION1/8"=1'-0"REAR ELEVATION1/8"=1'-0"RIGHT ELEVATION1/8"=1'-0"1'-0"7 7/16"1'-0"7 7/16"42" MIN BELOW FINISHED GRADEALL EXTERIOR FTGS TO BEFLASH OVER ALL EXT OPGSASPHALT SHINGLES6:12 PITCH6:12 PITCH612612AAAA40% TO 50% NEAR RIDGEVENT 1/300th OF ROOF AREAREMAINDER IN SOFFITPER IRC SECTION R806.240% TO 50% NEAR RIDGEVENT 1/300th OF ROOF AREAREMAINDER IN SOFFITPER IRC SECTION R806.22x TREATED6126121x CEDAR4129:12 PITCH2'-0"9:12 PITCH2'-0"9:12 PITCH6:126:126:126:124:12CCCCAAAABBBB1'-0"1'-0"1'-0"1'-0" 1'-0"1'-0"1'-0"1'-0" 1'-0"5 ROOF VENTS3 ROOF VENTS3 ROOF VENTS 1'-5"1'-0"9:129:129:121'-0"3'-6"2'-0"Secure door closed until deck isconstructed with a separate permit.Concept Approval ONLYSubject to Field InspectionInspectorDate2020MN BldgCode10/21/2020dmathews These plans, and the concept thereofor used without written consent. And may not be reproducedare the exclusive property of D.R. Horton Inc.,COPYRIGHT D.R. HORTON, INC. 2016C2.0XFINNEGAN 3035-C3.3-GRPC#753: 3-6-2020-LLPC#743,760,765,770: 4-22-20-LLPC#797: 7-9-20-LLNOTE:MECHANICAL EQUIPMENT LAYOUT WILL VARYPER PLUMBING, ELECTRICAL, MECHANICAL,STRUCTURAL AND/OR SITE CONDITIONSUTILITY / LAUNDRYUNFINISHEDCRAWL SPACE57'-0" 40'-8"6'-5" 57'-0"34'-0"23'-0"21'-0"2'-0"16'-2 1/4"17'-9 3/4"49'-0"19'-0"30'-0"19'-0"11'-0"5'-1"7'-10"1'-4 1/2"16'-3"1'-4 1/2"1'-1 1/2"8'-3"1'-7 1/2"16'-3" M.O.8'-3" M.O.UP7R2-816'-4"POURED CONC. WALL16x8 CONC. FTG.8" THICK, 3'-6" HIGH130 SQ. FT.UNEXCAVATED6" CURB (OMIT CURB AT GARAGE DOOR OPENINGS)6" THICK16"x8" FTG.POURED CONC. WALLMIN. 3'-6" BELOW GRADE6" CURB, 2" LEDGEPOURED CONC. WALL16"x8" CONC. FTG.8" THICKMIN. 3'-6" BELOW GRADE6" CURB, 2" LEDGEPOURED CONC. WALL16"x8" CONC. FTG.8" THICKMIN. 3'-6" BELOW GRADE2x6 LOOKOUT WALL2x6 STUDS AT 16" O.C. POURED CONC. WALLTREATED BOTTOM PLATE18x8 CONC. FTG.8" THICK, 3'-6" HIGHANCHORS AT 6'-0" O.C.14x8 CONC FTG4" HALF-HIGH CURBTREATED BOTTOM PLATE2x4 STUDS AT 16" O.C.2x4 BRNG WALL7'-3"22'-3"16'-2 1/4"3'-6"3'-6"10'-9 3/4"7'-6"TREATED 2x8's 16" ON CENTER 16" CONC. PIER FTGMIN. 3'-6" BELOW GRADE6x6 POST6'-1"2-2x8 FLUSH BEAM2-2x8 FLUSH BEAM2-2x8 FLUSH BEAMNOTE:3'-6" HIGH POURED CONC. FOUNDATION WALL TYPICALWDW SIZES GIVEN IN FEET AND INCHES (WIDTH x HEIGHT)BEAM & HEADER SIZES TO BE VERIFIED BY SUPPLIER/MFRBASEMENT PLANSCALE: 1/4"=1'-0"5'-5"5'-10"8"POURED CONC. WALL18"x8" CONC. FTG.8" THICKMIN. 3'-6" BELOW GRADE10'-4 1/4"13'-6 1/4"11'-7 3/4"13'-6 1/4"2'-8"DROPPED BEAM11 7/8" MFD I-JOISTSINSTALL PER MFRS SPECS6'-8"8"ANCHORS AT 6'-0" O.C.14x8 CONC FTG4" HALF-HIGH CURBTREATED BOTTOM PLATE2x4 STUDS AT 16" O.C.2x4 BRNG WALL10'-0"5'-0"DROPPED HDR4'-1"ANCHORS AT 6'-0" O.C.14x8 CONC FTG4" HALF-HIGH CURBTREATED BOTTOM PLATE2x4 STUDS AT 16" O.C.2x4 BRNG WALL10'-0"5'-0"DROPPED HDR3'-9"16'-2 1/4"7'-0"17'-5 3/4" S & W SLEEVE 11 7/8" MFD I-JOISTS INSTALL PER MFRS SPECS 11 7/8" MFD I-JOISTS INSTALL PER MFRS SPECS DBL JOIST AT COLUMN ABOVE 7'-0"COCKSILL POURED CONC. WALL16x8 CONC. FTG.8" THICK, 3'-6" HIGHANCHORS AT 6'-0" O.C.14x8 CONC FTG6" HALF-HIGH CURBTREATED BOTTOM PLATE2x6 STUDS AT 16" O.C.2x6 BRNG WALL30x30x12CONC. PAD FTG.THE FRAMER WILLINSULATE, POLY & INSTALLBEFORE FRAMING FULLOSB SHEATHING ON THEHEIGHT 2x4 FURRING WALLEXTERIOR 2X6 SIDE-WALLFULL HEIGHT 2x4 FURRING WALL2x6 EXTERIOR WALL IS FINISHED,NOTE: WHEN BEDROOMFAM./REC. RMBEDRM #4170 SQ. FT.385 SQ. FT.8'-0 3/4"9'-9"CPTCPT16X12 FRAMEDDOWN SOFFIT1'-4"RADON VENT PIPEPERFORATED 'T' PIPE TO& CRAWLSPACE SLABSEXTEND UNDER HOUSE7'-10"1'-4"THE FRAMER WILLINSULATE, POLY & INSTALLWALL BEFORE FRAMING FULLOSB SHEATHING ON THEHEIGHT 2x4 FURR WALLGARAGE/HOUSE 2X6 COMMON29'-6"9'-11"2-830x30x12CONC. PAD FTG.8'-0"5-0 BI-FOLD11 7/8" MFD I-JOISTSINSTALL PER MFRS SPECS12"DBL JOIST AT COLUMN ABOVE ACHVF.D.ERVDWWHSUMP NOTE: ROCK WHOLELOWER LEVEL CEILINGEXCEPT FOR 80 SQ FTAT MECHANICAL ROOM1'-7"3'-1"DROPPED HDR 49'-0"11'-6"6'-5"5'-2"6'-4"23'-10"25'-2"13'-8"7'-3"6-0 SGD3050 SH2x6 WALKOUT WALL2x6 STUDS AT 16" O.C. 8" POURED CONC. WALLANCHOR BOLTS AT 6' O.C.TREATED BOTTOM PLATE6" CURB, 2" LEDGE16x8 CONC. FTG.MIN. 3'-6" BELOW GRADECOCKSILLBATH51 SQ. FT.HD-FLRTPH36"TUB/SHWR24" TOWEL BAR2'-8"5'-0"7'-0"8'-7"2-8FRAMEDDOWN SOFFIT2-8GROUNDING ROD THRU PLATES20554 GLADE AVENUE PERMIT/CONST.PLANSLOT 2, BLK 3, CEDAR CROSSINGSPLAN OPTIONSWALKOUT BASEMENTFINISHED LOWER LEVEL BATHWINDOW & DOOR SCHEDULE-WALKOUTCALL-OUTU-FACTORROUGH OPENING6068 SGD0.3172 1/8" X 80"LOCATIONSHGCFAMILY ROOM0.32#10.3110.31BEDROOM3050 SH36 1/4" X 60 1/4"1/2"=1'-0"FRONT PORCH LEDGER SECTION6 78"7 14 "FLASHING ABOVEGRADETOP OF SUBFLOORTO TOP OF JOIST6 7/8" FROMAND BELOW TREATED2x8 LEDGERTRTD 2x8 JOISTS16" O.C.(8) 10d COMMON NAILS (AT LTS19-TZ STRAP)1/2"=1'-0"FRONT PORCH LEDGER DETAILRIM BOARD1-1/8" OSB11-7/8" I-JST 3/4" 1st FLOOR WALLSSUBFLOOR 8'-1 1/8" FOUNDATION WALL 3/4" SUBFLOOR6-7/8"7-1/4"2x8 PORCHLEDGER2x6 EXTERIOR WALL. 2"MIN...2" FROM TOPLAG SCREW TO BEMIN. 2" FROM EDGE21" O.C. UP TO 8'-0" SPAN16" O.C. UP TO 10'-0" SPANSUBFLOOR TOTOP OF LEDGEROF LEDGER19.2" O.C.I-JOISTSUSP LTS19-TZ , (4) PER DECK RATED @ 750# EACHLATERAL LOAD CONNECTION:3/8" DIA. LAG BOLT MIN. 3" PENETRATION(THRU SILL PLATES)INTERIOR STRAPS SPACED EVENLYLINES UP WITH BOTTOMBOTTOM OF LEDGEROF SILL PLATE1/2" DIAMETER LAG SCREWSINSTALLED STAGGERED IN 2 ROWSLAG SCREWS W/ WASHER TO BE-OR- 3/8" DIA. ANCHOR BOLTS (THRU FOUNDATION)OUTSIDE STRAPS MAX. 24" FROM END OF LEDGER14" O.C. OVER 10'-0" SPANUSP LTS19-TZ , (4) PER DECK RATED @ 750# EACHLATERAL LOAD CONNECTION:3/8" DIA. LAG BOLT MIN. 3" PENETRATION(THRU SILL PLATES)INTERIOR STRAPS SPACED EVENLY-OR- 3/8" DIA. ANCHOR BOLTS (THRU FOUNDATION)OUTSIDE STRAPS MAX. 24" FROM END OF LEDGER(8) 10d COMMON NAILS (TOP ROW)2X4X24 BLOCKING2X4X24 BLOCKINGNAILS STAGGERED 1"11-7/8" I-JST1/2" DIA. LAG SCREWS3/8" DIA. LAG BOLTSTOP/SILL PLATE W/ATTACH RIM BOARD TO8D NAILS @ 6" O.C.TO SUBFLOOR W/ATTACH 1-1/8" RIM BD.8D NAILS @ 6" O.C.TO TOP & BOTTOM OFATTACH 1-1/8" OSB RIM BDEACH FLOOR MEMBERW/ 8D NAILSSIMPSON DTT1Z ORSIMPSON DTT1Z OR1x10 CEDAR SKIRTAT DROPPED BEAM1x10 CEDAR SKIRTAT DECK RIM JOISTBLOCKING AS REQ.FOR SKIRT SUPPORTDROPPED BEAMUSP LTS19-TZ BRACINGAND WOOD BLOCKINGSEE PAGE 5 FOR DETAILS2x12 BLOCKING2x12 BLOCKINGPORCH SKIRT DETAIL1/4"=1'-0"SIMPSON DTT1Z ORFOUNDATION INSULATIONFRONT FOUNDATION WALL:-17 SQ FT/49 LIN FT= 0.34 RATIOR-10REAR FOUNDATION WALL:-25 SQ FT/49 LIN FT= 0.51 RATIORIGHT SIDE FOUND. WALL:-39 SQ FT/40.6 LIN FT= 0.96 RATIOLEFT SIDE FOUND. WALL:-46 SQ FT/34 LIN FT= 1.35 RATIO-FOUNDATION INSULATIONRATINGS ARE BASED ONLESS THAN 2.6 AIR CHANGESPER HOUR DURING THE AIRLEAKAGE TESTR-10R-10R-10REQUIREMENTSInterior BWP AboveInterior BWP Above777755(2)9-1/2 Versa-Lam(2)7-1/4 Versa-Lam(3)11-7/8 Versa-LamUFER Ground-Provide 20' Rebar in footing and stubup near electrical service panel. These plans, and the concept thereofor used without written consent. And may not be reproducedare the exclusive property of D.R. Horton Inc.,COPYRIGHT D.R. HORTON, INC. 2016C3.0XFINNEGAN 3035-C3.3-GRPC#753: 3-6-2020-LLPC#743,760,765,770: 4-22-20-LLPC#797: 7-9-20-LLMFD TRUSSES AT 24" O.C. 57'-0"34'-0"23'-0"21'-0"2'-0"49'-0"19'-6"29'-6"18'-6"11'-0"UP7RDN8RBEDRM #2BEDRM #1BATH#1FOYERLIVINGROOMDINING6068 SGD2W 3050 SH3-02-82-8HD-FLRCPTCPTCPTHD-FLRVAULTED8'-1 1/8" CEILINGGARAGESLOPE TO DOORS4" CONC FLOOR664 SQ. FT.TYPICAL 2x6 GARAGE WALLSNOTE: 5-0 FBGLTUB/SHWR1ST FLOOR PLAN1796 SQ. FT.NOTE:8'-1 1/8" PLATE HEIGHT TYPICALWDW SIZES GIVEN IN FEET AND INCHES (WIDTH x HEIGHT)TYP. FIRST FLOOR WINDOW HEAD HEIGHT AT 6'-10 1/2" U.N.O.BEAM & HEADER SIZES TO BE VERIFIED BY SUPPLIER/MFRSCALE: 1/4"=1'-0"9'-0"9'-6"5'-3"5'-9"W.I.C.CPT60"BEDRM #3CPTFLEXCPT22x30ATTICACCESS8'-1 1/8" CEILING2040 SHGARAGE-TO-HOUSE COMMON WALL5/8" GYP. BOARD ONTO UNDERSIDE OF ROOF SHEATHING24" TOWEL BAR GAS FPW/ WOOD CAP42" HIGH HALF WALL5'-1"4'-1 1/8"3'-7"VAULT 8' CLG.VAULT RIDGECPT.HD FLR 22x30ATTICACCESS 24" TOWEL BAR3'-1"SHWR34x60 FBGLTEMPC-CD-D2-82-82-82-82-8ENSUITEBATHHD-FLRTPH2-82-82-83050 SH3050 SH2-8VAULTEDVAULT 2W 3050 SH16x7 OVERHEAD DOOR8x7 OVERHEAD DOOR(2) 2-0(2) 2-02W 3050 SH2-057'-0" 6'-1"13'-10"COVERED PORCH122 SQ. FT.4"12" WIDE DROPPED SOFFIT(SEE SECTION)4"13'-6"40'-8"49'-0"23'-10"25'-2"5'-8"10'-8"10'-5"8'-0"8'-4"2'-4"8'-1"2'-4"8'-5"9'-10"5'-7"6'-4"17'-7"7'-7"3'-6"4'-1"11'-3"11'-7 1/2" 6'-5"9'-11" 16'-4"6'-8"29'-6"VAULT 2'-8" MFD TRUSSES AT 24" O.C. MFD TRUSSES AT 24" O.C.MFD TRUSSES AT 24" O.C.2x6 WALLW/ WOOD CAP42" HIGH HALF WALL5'-0"1-612"3'-6"7'-3"7'-1 1/4"2'-10"CPT.HD FLRHD-FLR10'-0"6'-0"2'-6"3'-0"12'-8"3'-8"5'-11"5'-0"7'-0 1/4"3'-9 1/2"3'-6"19'-10"3'-8 1/4"3'-1"3'-3"5'-8"4'-0"6'-7"2'-3 1/2"3'-7 1/2"6'-6"6'-2"LIN. CLST.16'-0"3'-6"3'-8 1/4"TYPICAL PORCH COLUMN:8x8 MFD COLUMN W/2x6 CAP & BASE AND4x4 ANGLED BRACEGIRDER TRUSSMFD TRUSSES AT 24" O.C.2W 2020 FX2'-4"9'-0 3/4" INSIDE FRAMINGKITCHENHD-FLRVAULTED6'-11"12" OVERHANGCABINETS20 AMP.MICRO HOODCIRCUITRANGE6'-0"2'-4"2'-4" 6'-10"3'-6" SINK DW 2'-6"3'-6 1/2"3'-0"REF.14'-4 1/4" 7'-0 1/2"2-45'-0"24'-0 1/2" 5'-2 1/4"11'-9 3/4"2x4 WALL5'-0"6'-10 1/4"10"3032 SHSUBFLOOR TO43 1/2" FROM TOP OFSET KITCHEN WINDOWSRGH.OPG. OF WINDOW36"TPH7-0 OPGRADONVENT PIPE RETURN1/2BHD-FLR24" TOWEL BARTPH2-42-84'-7 3/4"1'-7 1/4"2'-3 1/4"4'-11 3/4"CENTRAL 2x6 WALL5'-10 1/4"4'-11 1/2"2'-3"2x6 WALL3-8 x 7-0 OPG 6'-1 3/4"1'-7 1/4"1'-5"2'-6"4'-0" 6'-8"24'-1"W.I.C.CPT2'-3 3/4"14'-4 1/4"12'-11"5'-0"10"37"x34-3/4"S/RGAS FIREPLACE ELEVATION1/4"=1'-0"2'-10 3/4"RGH OPGDV3732 GAS FPFIREPLACE TRIM KIT2x10 PLATFORM10"2'-10 3/4" 2'-6"20554 GLADE AVENUE PERMIT/CONST.PLANSLOT 2, BLK 3, CEDAR CROSSINGSPLAN OPTIONSGAS FIREPLACEWINDOW & DOOR SCHEDULECALL-OUTU-FACTORROUGH OPENINGLOCATIONSHGC#3-0 DOOR0.3138 1/4" X 83 1/4"FOYER0.231STUDYFLEX2W 3050 SH10.310.3172 1/8" X 60 1/4"DINING ROOM6068 SGD10.3172 1/8" X 81"0.32BEDROOM #33050 SH10.3136 1/4" X 60 1/4"0.31BEDROOM #23050 SH10.3136 1/4" X 60 1/4"0.31ENSUITE BATH10.310.31LIVING ROOM2W 3050 SH72 1/8" X 60 1/4"BEDROOM #12W 3050 SH10.310.3172 1/8" X 60 1/4"2040 SH24" X 48"10.310.313032 SHKITCHEN10.3136 1/4" X 38"0.3110.310.32DINING ROOM2W 2020 FX47 5/8" X 24"(2)9-1/2 Versa-Lam(2)9-1/2 Versa-Lam(2)9-1/2 Versa-Lam(2)9-1/2 Versa-Lam(2)7-1/4 Versa-Lam(2)11-7/8 Versa-Lam(2)9-1/2 Versa-Lam3.555PFHPFH-Min. 15" clearance to anyobstruction from center ofW.C., 24" in front(typ). CSSD/CMDSPRINKLERSYSTEMRECEPTACLESSCALE: 1/4"=1'-0"ELECTRICAL PLAN1ST FLOORSSSWPSDSDSFANThese plans, and the concept thereofor used without written consent. And may not be reproducedare the exclusive property of D.R. Horton Inc.,COPYRIGHT D.R. HORTON, INC. 2016C4.0XFINNEGAN 3035-C3.3-GRPC#753: 3-6-2020-LLPC#743,760,765,770: 4-22-20-LLPC#797: 7-9-20-LLSCALE: 1/4"=1'-0"ELECTRICAL PLANBASEMENTLOW VOLTAGESYSTEM RECEPTACLEA/CWPSDSSD/CMDSSLLLLGFIWPCS LLLLLLCLSDDLLDSSMART HOMESYSTEM RECEPTACLECLSCUTILITY / LAUNDRYUNFINISHEDCRAWL SPACEUNEXCAVATEDFAM./REC. RMBEDRM #4S & W SLEEVE SSLBEDRM #2BEDRM #1BATH#1FOYERLIVINGROOMDININGGARAGEW.I.C.BEDRM #3FLEX22x30ATTICACCESS22x30 ATTIC ACCESS ENSUITEBATHCOVERED PORCHS S DS LLLLSSSS LLSS FANFANGFIS SSSSS LLLLSDFOR FUT. WSLLSKITCHENLS S DISP. DW USB CL15 AMP CIRCUITFOR POWER VENTW/ SINGLE RECEPTACLEGFIACHVF.D.ERVSEPERATE 15 AMP CIRCUITW/ SINGLE RECEPTACLEWHSUMPROUGH-INCEILING FANSGFIGFI STCHIMESDSHCP1/2BSSGFILSSSS SWPSGFIFANSLSBATH 20554 GLADE AVENUE PERMIT/CONST.PLANSLOT 2, BLK 3, CEDAR CROSSINGSPLAN OPTIONSWALKOUT BASEMENTFINISHED LOWER LEVEL BATHGAS FIREPLACE These plans, and the concept thereofor used without written consent. And may not be reproducedare the exclusive property of D.R. Horton Inc.,COPYRIGHT D.R. HORTON, INC. 2016C5.0XFINNEGAN 3035-C3.3-GRPC#753: 3-6-2020-LLPC#743,760,765,770: 4-22-20-LLPC#797: 7-9-20-LL8'-1 1/8"8'-1 1/8"1'-0"1267 7/16"MFD TRUSS4" CONC. FLOOR3/4" 250 SUBFLOOR11 7/8" MFD I-JOISTS4" CONC. FLOORGARAGEBEDRM #3BEDRM #421'-0"34'-0"3'-6" POUREDCONC WALL1/4"=1'-0"CROSS SECTION A-ABEDRM #2BATH3 1/2" CONC. FLOOR3/4" 350 SUBFLOOR11 7/8" MFD I-JOISTS8'-1 1/8"1'-0"1267 7/16"2x8 JOISTS5/4" DECKINGPOURED CONC. WALL18"x8" CONC. FTG.8" THICKMIN. 3'-6" BELOW GRADESET ON 6" THICKPOURED CONC. WALLCONC. SIDEWALKDROPPED BEAMKITCHENUNFINISHEDCRAWL SPACE40'-8"6'-1"3'-6" POUREDCONC WALL1/4"=1'-0"CROSS SECTION B-BDININGFLEXROOM9'-3 1/4" 6 7/8"MFD TRUSS3122-2x8FLUSH BEAM5'-0"1/4"=1'-0"CROSS SECTION A1-A1MFD TRUSS4" CONC. FLOOR3/4" SUBFLOOR11 7/8" MFD I-JOISTS4" CONC. FLOORGARAGE34'-0"3'-6" POUREDCONC WALLMUDRM9'-3 1/4" 8'-1 1/8"8'-1 1/8"1'-0"1267 7/16"BEDRM3/4" SUBFLOOR11 7/8" MFD I-JOISTS8'-1 1/8"FRAMED DOWNCEILING12'-10 3/4"OSB SHEATHING& POLY BY FRAMERSFAMILY/REC ROOM12613'-6 1/2"UTILITY / LAUNDRY23'-0"126MFD TRUSSMFD TRUSS1261241'-0" These plans, and the concept thereofor used without written consent. And may not be reproducedare the exclusive property of D.R. Horton Inc.,COPYRIGHT D.R. HORTON, INC. 2016C6.0XFINNEGAN 3035-C3.3-GRPC#753: 3-6-2020-LLPC#743,760,765,770: 4-22-20-LLPC#797: 7-9-20-LLGARAGE SLAB LEDGE DETAIL1/2" SHEATHINGMIN. R-20 INSULATION2x6 STUDS AT 16" O.C.HOUSE WRAPSIDING PER ELEV.BARRIER PASTACOUSTICAL SEALANTEXTEND POLY VAPOR1-1/2" THERMAX2-1/4"X12" DUCTINSULATION(R-10 x 2)1/2"=1'-0"WALL DETAIL1/2"=1'-0"THE SLOPING OF THE FLOORBE PROTECTED WHEREVER4" CONC. GARAGE FLOORRIGID INSULATION MUSTCREATES AN EXPOSURE.5/8" GYP. BD.11 7/8" MFD I-JOISTS3/4" 250 SUBFLOOR4'-9 5/8"3 1/2" CONC. FLOOR3/4" 350 SUBFLOOR11 7/8" MFD I-JOISTS4'-4 1/8"8'-1 1/8"8'-1 1/8" 8'-1 1/8"3'-6" POUREDCONC WALLLIVINGROOM1/4"=1'-0"CROSS SECTION C-C4" CONC. FLOORUNFINISHEDCRAWL SPACEBEDRM #316x8 CONC. FTG.5000 PSI TESTED -OR-APPROVED ADMIXTUREI-JOISTS PER PLANVARIESSEE PLANVARIES122x6 STUDS AT 16" O.C.BLOCK AT MIDPOINT2x6 BEARING WALL14x8 CONC. FTG.6" HALF HIGH CONC. CURB. BLK.1/2" ANCHOR BOLTSOMIT BEARING WALLAT STEEL OR LVL BEAMR-49 INSUL.MFD TRUSSESA I R CHU T E S APPLIED ON WARM-IN-WINTER SIDE OFTHERMAL INSULATION AT ABOVE GRADEFRAMED WALLS, RIM JOISTS, FLRS AND CLGSNOTEDUNLESSOTHERWISENOTEDUNLESSOTHERWISEOVER 1/2" SHEATHINGSHINGLES OVER FELT PAPERRIGID WIND WASH INSTALLED EXTENDINGBARRIER MUST BETO WITHIN 1-1/2" to 2"FROM BOTTOM OFROOF SHEATHING4 MIL. POLY VAPOR / AIR BARRIERALUMINUMCORNICEVENTS40% TO 50% NEAR RIDGEVENT 1/300th OF ROOF AREAREMAINDER IN SOFFITPER IRC SECTION R806WATERPROOFINGWATCH DOGTREATED SILL PLATEAPPROVED ANCHORPER CODE (IRC R403.1.6)16x8 CONC. FTG.RUN INTO SUMP BASKETCONTINIOUS DRAIN TILEWHERE APPLICABLETREATEDSILL PLATEVERTICAL REINFORCINGAS SOIL COND. REQUIREW/ FOAM SILL SEALMIN. 42" BELOW FINISHED GRADEALL EXTERIOR FOOTINGS TO BE4" INCH CLEAN AGGREGATE ORCONCRETE SLAB AND PREPARED SUBGRADE6 MIL POLY V.B. W/ LAPPED SEAMS 12" BETWEENAPPROVED GAS-PERMEABLE LAYERPASSIVE SUB-SLAB DEPRESSURIZATIONSYSTEM REQUIRED PER MINNESOTARESIDENTIAL ENERGY CODE 1322.2100TYPICAL WALL SECTION (4-12-2016)1/2"=1'-0"POURED CONC. WALL8" THICK, 3'-6" HIGH2x6 LOOKOUT WALL2x6 STUDS AT 16" O.C.ANCHOR BOLTS AT 6' O.C.8" THICK, 42" HIGHPOURED CONC. WALL16x8 CONC. FTG.TREATED BOTTOM PLATE2x6 WALKOUT WALL2x6 STUDS AT 16" O.C.ANCHOR BOLTS AT 6' O.C.POURED CONC. WALL(6" CURB, 2" INT. LEDGE)16x8 CONC. FTG.TREATED BOTTOM PLATE8" THICK, 42" HIGHOPENINGS, JOINTS AND SUMPSFOUNDATION WALL & SLABSEAL JOINT BETWEEN3-1/2" CONC. FLOOR SEALED ATR-10 RIGID INSULATIONINTENDED FOR EXTERIOR USEASTM C578, C612 or C1029INSTALLED PER MFR'S SPECS8'-1 1/8"1/2" EXT. SHEATHING5-1/2" BATT INSULATION2x6 STUDS AT 16" O.C. W/HOUSE WRAPSIDING PER ELEV.3/4" SUBFLOORSEE PLANVERTICAL CLEARANCE OF NOT LESS THANTHE EXTERIOR WALL TOP PLATETO THE ROOF SHEATHINGSIX INCHES FROM THE OUTSIDE EDGE OF6" MIN. HEEL 6'-0" OF ICE & WATER SHIELDINSTALL PER MFR'S SPECSTERMINATE 12" ABOVE ROOF2x6 SUBFASCIASEALANT BY CARPENTERPRIOR TO SHEATHINGPROVIDE RECEPTACLE FOR FUTURE RADON FANVENT PIPE SHALL BE INSTALLED WITH A MINIMUM24" HORIZONTAL CLEARANCE AND 36" VERTICALCLEARANCE TO ALLOW FOR FUTURE INSTALLATIONOF RADON FAN (ACTIVE SYSTEM)W/ VAPOR BARR.5/8" GYP. BD.W/ APPROVED SEALANT1/2" GYP. BD.SEAL BEHIND POLY.SEAL BEHIND POLY.PASSIVE RADON VENTLABEL ON EACH FLR"RADON REDUCTION SYSTEM"TO EACH SIDE OF "T" FITTING IN AGGREGATE10' SECTION OF PERFORATED PIPE CONNECTEDABOVE GRADE PROTECTIONOF INSULATION EXTENDING6" BELOW GRADEFINISHED GRADEWILL VARYABOVE GRADE PROTECTION OFINSULATION EXTENDING6" BELOW GRADE(WHERE APPLICABLE)2x6 EXTERIOR WALL(SEE OSWELL ENGINEERING)R-0.62R-21R-N/AR-N/ATOTAL R-VAULE:=20.92INSIDE AIR FILMR-0.681/2" GYP BD.R-0.45OUTSIDE AIR FILMR-0.173" MIN. POLYURETHANE FOAMAT PERIMETER R=20GYP. BD. EXCEPT 80 SF AT1/2" SAG-RESISTANTTHRU UNCONDITIONEDSPACES TO HAVER-4 INSUL. (MIN)ALL NON-BEARING PARTITION WALLSTO BE FRAMED AT 16" ON CENTER5000 PSI TESTED -OR-APPROVED ADMIXTURETHE MECHANICAL ROOMOF FOUNDATION WALL(ONLY IF REQUIRED PERFOUNDATION CALCULATIONS)R-5 RIGID INSULATION-ON INSIDEPASSIVE RADON VENTLABEL ON EACH FLR"RADON REDUCTION SYSTEM"R-5 RIGID INSULATIONTAPE & SEAL AT TOPR-10 RIGID INSULATIONINTENDED FOR EXTERIOR USEASTM C578, C612 or C1029INSTALLED PER MFR'S SPECS3'-6"VENT PIPE RUNNINGGYP. BD.1/2" SAG-RESISTANT8'-1 1/8" 8'-1 1/8"(ONLY IF REQUIRED PERFOUNDATION CALCULATIONS)INSULATE, POLY & INSTALLBEFORE FRAMING FULLOSB SHEATHING ON THEHEIGHT 2x4 FURRING WALLEXTERIOR 2X6 SIDE-WALLFINISHED, FRAMER WILLNOTE: WHEN L.L. BEDRM1'-6 5/8"1"=1'-0"DETAIL (L.L. BEDRM)LOOKOUT FINISH WALL2x6 TREATEDSILL PLATE1x6SILL PLATE2x4 INTERIORWALL2x_ TREATEDBLOCKING1/2" GYP. BD.1/2" GYP BD LEDGE6-1/2" CAP BOARDSHOE PERIMETERWINDOW FRAMEEXTERIOR SHEATHINGR-10 EXTERIORINSULATIONR-5 INTERIORINSULATION (IFREQ'D PER CODE)1/4"=1'-0"CROSS SECTION D-D11 7/8" MFD I-JOISTS3/4" 250 SUBFLOOR4'-9 5/8"4'-4 1/8"BEDROOM4" CONC. FLOORUNFIN.CRAWLSPACELIVINGROOMBEDRMDININGROOM5'-0" MAXCLEAR OPENING BOTTOM OF HEADER TO BEFLUSH W/ BOTTOM OF I-JOISTS2X6 STUDS, 16" O.C.MECHANICAL DUCTWORKMECH ROOM OPENING1/2"=1'-0"MECHANICAL ROOM SIDE 2-2X10 HEADERCRAWLSPACE SIDE 11-7/8" I-JOISTS FOUNDATION DETAILAT FOOTING STEP LOCATIONS1F1DescriptionDateRevisionProject Number:Date:F11Sheets: of2Print Name:Signed: License Number:Nick Hanson46665Date:I hereby certify that this plan, specification or reportwas prepared by me or under my direct supervisionand that I am a duly Licensed Professional Engineerunder the laws of the State of Minnesota.January 1, 20200.0011-1-202020 FOUNDATION GUIDEWALL SECTIONWALKOUT WALL CONDITION2F1WALL SECTIONLOOKOUT WALL CONDITION3F1WALL SECTIONEXTERIOR UNBALANCED FILLCONDITION4F1WALL SECTIONFULL HEIGHT WALL CONDITION5F1REBAR TABLE6F1SITE ADDRESS:City:State:Zip:MNCOPYRIGHT HANSON GROUP LLC 2020©3407 Kilmer Lane NorthSuite 4Plymouth, MN 55441Tel 612-708-3572www.hansongroupmn.comDRAWING USE GUIDELINES AND LIMITATIONSTHE CONTRACTOR LISTED IN THE TITLE BLOCK BELOW IS LICENSED BY THE HANSON GROUP TO USE THISPACKET WITHIN THESE LIMITATIONS NOTED FOR PROJECTS WHICH THE LICENSEE IS DIRECTLY RESPONSIBLE.THE LICENSEE MAY RELEASE THIS PACKET TO ITS SUB-CONTRACTORS AND CLIENTS FOR USE IN THEPROCUREMENT OF BUILDING PERMITS FOR PROJECTS WHICH THE LICENSEE IS USING THESE DRAWINGS.THE FOUNDATION GUIDELINES ARE TO BE ISSUED TO THE APPROPRIATE BUILDING DEPARTMENT INACCORDANCE WITH THEIR APPROVED PROCEDURE FOR USE BY THE BUILDING AGENCY DURING PLAN REVIEWAND INSPECTIONS.LIMITATIONS1.BASEMENT FOUNDATION WALLS TEN FOOT OR LESS IN CLEAR HEIGHT (FROM TOP OF FLOOR SLAB TO TOPOF CONCRETE WALL AT SILL PLATE BEARING-NOT NECESSARILY BASEMENT CEILING HEIGHT).2.STRUCTURE HEIGHT IS NOT TO EXCEED TWO STORIES ABOVE THE BASEMENT.3.OVERALL BUILDING IS ASSUMED TO FALL WITHIN THE PRESCRIPTIVE LIMITATIONS OF THE CODE. A SITESPECIFIC PLAN REVIEW HAS NOT BEEN PERFORMED.4.STRUCTURES CONSTRUCTED OF WOOD FLOOR, WOOD ROOF, AND WOOD WALLS ONLY. NO PRECAST ORSTRUCTURAL CONCRETE BEARING ON FOUNDATION WALLS IS PERMITTED.5.EXTERIOR GRADE SLOPING DOWN AND AWAY FROM THE FOUNDATION WALLS.6.ANY CASE BEYOND THE ABOVE NOTED ITEMS REQUIRES SEPARATE AND SPECIFIC STRUCTURALENGINEERING DOCUMENTS.COLD WEATHER GUIDELINES:1.THE CONTRACTOR AND CONCRETE SUPPLIER ARE TO WORK TO OBTAIN A MIX DESIGN WHICH WILLADEQUATELY PERFORM UNDER THE EXPECTED CONSTRUCTION CONDITIONS. THE USE OF ADDITIONALCEMENT, HIGH-EARLY STRENGTH CONCRETE, AND/OR ACCELERATOR IS RECOMMENDED ATTEMPERATURES AND CONDITIONS EXPECTED LESS THAN TWENTY DEGREES F.2.DELIVER CONCRETE WARM AND IN A TIMELY MANNER. PLACE CONCRETE EARLY IN THE DAY WHENPOSSIBLE.3.DO NOT ADD ADDITIONAL WATER TO THE CONCRETE. THE USE OF WATER REDUCING AGENTS ISRECOMMENDED WHEN WORKABILITY CONCERNS EXIST. NO CONCRETE IS TO BE PLACED ON SNOW OR INCONTACT WITH FROZEN MATERIALS.4.REBAR DOES NOT NEED TO BE PRE-HEATED, BUT IS TO BE FREE OF FROST, SNOW, AND ICE.5.BLANKETS OR OTHER ACCEPTED PROTECTION IS HIGHLY RECOMMENDED FOR THE TOP 24" OF THE WALLSWHEN THE AIR TEMPERATURE IS LESS THAN TEN DEGREES F AND FOR THE FULL HEIGHT OF THE WALLWHEN THE AIR TEMPERATURE IS LESS THAN ZERO DEGREES F.**THE ABOVE COLD WEATHER GUIDELINES ARE GENERAL RECOMMENDATIONS AND ALL ACI COLD WEATHERREQUIREMENTS ARE TO BE FOLLOWED AT THE RESPONSIBILITY OF THE LICENSEE.MATERIALSCONCRETE WALLS:F'c = 3000 PSI @ 28 DAYSMIX DESIGN AND PROPORTIONED BY CONCRETE SUPPLIERCONCRETE FOOTINGS:F'c = 5000 PSI @ 28 DAYS (OR 3000 PSI WITH AN APPROVED ADMIXTURE THAT PROVIDESA WATER AND VAPOR RESISTANCE AT LEAST OR EQUIVALENT TO 5000 PSI CONCRETE.AGGREGATE: FOOTINGS - 1 12" MAX. WALLS/SLABS - 34" MAX.REINFORCING STEEL: #4- BARS - ASTM A615 GRADE 40#5+ BARS - ASTM A615 GRADE 60TREATED SILL PLATE:SYP GRADE #2 OR BETTERALLOWABLE SOILBEARING PRESSURE1,500 PSF MINIMUMGENERAL NOTES1.DO NOT BACKFILL BASEMENT WALLS UNTIL THE CONCRETE HAS REACHED A MINIMUM COMPRESSIVESTRENGTH OF 2,250 PSI. IN ADDITION, DO NOT BACKFILL UNTIL THE BASEMENT WALLS ARE LATERALLYSUPPORTED BY THE FINAL INSTALLED FLOOR CONSTRUCTION AT THE TOP AND BOTTOM, UNLESSADEQUATE SHORING IS INSTALLED AS REQUIRED. SHORING IS THE SOLE RESPONSIBILITY OF THE GENERALCONTRACTOR.2.STRIP FOOTING MAY BE PLACED AT ELEVATIONS LOWER THAN SHOWN IN THE DETAILS.3.112" DEEP BY 312" WIDE BY CONTINUOUS KEYWAYS MAY BE USED IN LIEU OF DOWELS FOR FULL HEIGHT ANDFROST WALLS.4.STRIP FOOTING TO WALL CENTERLINES MAY BE OFFSET UP TO 2", HOWEVER, A MINIMUM OF 2" OF STRIPFOOTING IS TO EXTEND BEYOND THE WALL FACE ON EACH SIDE.5.PROVIDE CODE REQUIRED FROST PROTECTION TO THE BOTTOM OF ALL FOOTINGS.6.SLOPE GRADE DOWN AND AWAY FROM THE STRUCTURE A MINIMUM OF 6" WITHIN THE FIRST TEN FEETUNLESS ADEQUATE DRAINAGE OR SWALES ARE PROVIDED.7.BOTH MATERIALS AND INSTALLATION OF DRAIN TILE, WATER-PROOFING, CONTROL JOINTS, FLASHING, ANDINSULATION ARE TO BE IN ACCORDANCE WITH THE CODE BY THE GENERAL CONTRACTOR, UNLESS NOTEDOTHERWISE.8.ALL WALL WIDTHS SHOWN ARE NOMINAL DIMENSIONS, UNLESS NOTED OTHERWISE. OVERALL WALLTHICKNESS MAY VARY BY UP TO 12" FROM THAT SHOWN ON THE DRAWINGS.9.REINFORCING PLACEMENT TOLERANCE IS NOT TO EXCEED 12". BARS BEING SPLICED ARE TO BE WITHIN 2"OF CENTERLINE. MINIMUM SPLICE LENGTHS ARE 30 BAR DIAMETERS FOR GRADE 40 STEEL AND 48 BARDIAMETERS FOR GRADE 60 STEEL. TYING IS NOT REQUIRED PROVIDED THESE TOLERANCES ARE MET.10.PROVIDE MATCHING HOOK BARS FOR ALL HORIZONTAL BARS AT WALL CORNERS AND INTERSECTIONS.HORIZONTAL BARS MAY BE PLACED ANYWHERE WITHIN THE WALL AS LONG AS A 2" MINIMUM CLEAR COVERIS ACHIEVED ON ALL SIDES.11.REINFORCING MAY BE BUNDLED UP TO A MAXIMUM OF THREE BARS.12.DOWELS MAY BE DRILLED AND GROUTED IN PLACE. VERTICAL BARS AND DOWELS DO NOT NEED TO ALIGN.VERTICAL BARS MAY BE DRILLED AND EMBEDDED 5" INTO THE STRIP FOOTING IN LIEU OF DOWELS.13.THE BOND BETWEEN CONCRETE AND REINFORCING WILL NOT BE APPRECIABLY REDUCED IF VERY MINORFORM OIL IS PRESENT FOR THE CONDITIONS CONTAINED WITHIN THESE DRAWINGS.14.SILL PLATES ARE TO BE ANCHORED WITH A MINIMUM OF TWO ANCHORS PER SILL SECTION. ALL SECTIONSARE TO HAVE AN ANCHOR WITHIN 4" TO 12" OF EACH END. AN ANCHOR IS TO BE PLACED AT ALL WALLCORNERS AND INTERSECTIONS ON WALLS MORE THAN TWO FEET IN LENGTH. WALLS TWO FEET OR LESS INLENGTH REQUIRE A MINIMUM OF ONE ANCHOR. REQUIREMENTS FOR SHEAR WALLS AND BRACED PANELSMAY BE IN EXCESS OF THESE REQUIREMENTS. TWO INCH WASHERS ARE ONLY REQUIRED AT FULL HEIGHTFOUNDATION WALLS. BUILDING DESIGNER IS TO ACCOMMODATE LOAD PATH FOR ANY VERTICAL LOADTRANSFER OVER A SILL PLATE OVERHANG CONDITION.15.ANCHOR BOLTS 12" DIAMETER OR LARGER ARE NOT REQUIRED TO BE CORROSION PROTECTED INACCORDANCE WITH CODE SECTION R317.3.1 EXCEPTION 1.16.ALL PRE-MANUFACTURED FASTENERS AND CONNECTORS ARE TO BE INSTALLED IN ACCORDANCE WITHTHE MANUFACTURER'S REQUIREMENTS.17.FLOOR BLOCKING IS ONLY REQUIRED AT FULL HEIGHT FIRST FLOOR NON-BEARING FOUNDATION WALLS.18.CARE IS TO BE TAKEN DURING CONCRETE PLACEMENT TO MINIMIZE INADEQUATE HORIZONTAL ANDDIAGONAL COLD JOINTS, AND TO PREVENT THESE JOINTS ENTIRELY IN WALLS WITHOUT VERTICALREINFORCEMENT. ADEQUATELY VIBRATE CONCRETE AT POTENTIAL JOINT LOCATIONS AS REQUIRED,BASED ON PLACEMENT CONDITIONS TO ELIMINATE HONEYCOMBING AND TO ENSURE SUFFICIENT BONDINGIS ACHIEVED.19.TOP AND BOTTOM OF FOUNDATION WALLS ARE TO BE LATERALLY SUPPORTED PRIOR TO BACKFILLING.MEANS AND METHODS OF LATERAL SUPPORT ARE BY OTHERS.EQUIVALENT REBAR TABLEFOR BUNDLED HORIZONTAL BARS(2)#4 = (1)#6(3)#4 = (2)#5(3)#5 = (2)#6GRADE 60 #6 VERTICAL BAR SPACING FOR FULL HEIGHT WALLS w/ F'c = 3000 PSIALTERNATIVE TO CODE TABLE R404.1.2EQUIVALENT VERTICAL REBARSUBSTITUTION TABLEBACKFILL TYPECLEAR HEIGHT(SEE 5/F1)BACKFILL HEIGHT(SEE 5/F1)8'-0"9'-0"10'-0"7'-6"7'-0" OR LESS8'-6"8'-0"7'-0"6'-0" OR LESS9'-6"9'-0"8'-0"7'-0"6'-0" OR LESS8"10"12"8"10"12"8"10"12"NONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONE* = NONE IF F'c = 4,000 PSI*36"*36"*36"*36"*36"*36"36"36"36"36"36"36"36"36"24"24"24"24"SAND (30 PSF/FT)WALL THICKNESSSANDY CLAY (45 PSF/FT)WALL THICKNESSCLAY (60 PSF/FT)WALL THICKNESS#6 @ 24" = #5 @ 18" = #4 @ 12" (GRADE 60) = #4 @ 8" (GRADE 40)(1)#6 = (2)#4 (GRADE 60)#6 @ 36" = #5 @ 24" = #4 @ 18" (GRADE 60) = #4 @ 12" (GRADE 40)(2) #4 HORIZONTAL BARSBOTH TOP & BOTTOMEXTENDED AT LEAST 24"BEYOND EACH END OF STEPSTABLE BANKHIGH FOOTING MAY BEEXTENDED PROVIDEDBARS ARE PLACED ASSHOWNHORIZ. BARSTOP & BOTTOM6" MIN THICK CONCRETEFOUNDATION, SEE OTHERDETAILS FOR MORE INFOOPTIONAL CONTROL JOINTAT EACH END OF STEP72" MAX SPANEQ.EQ.24" MINDETAIL B3" MIN TYPCONCRETE STRIPFOOTING11BDETAIL A36" MINSTEP2 x STEPSTEP NOTE:DO NOT LOCATE CONCENTRATED LOADS IN EXCESS OF 2,000 PLF OR 10,000 POUNDS ABOVE STEPLOCATIONS SHOWNREAR FROST WALLLOOKOUTWALLFULL HEIGHTWALLGARAGE FROSTWALLELEVATIONSHOWN FORREPRESENTATIONPURPOSES ONLY-MAY NOT APPLYELEVATIONSTEP SPACING REQUIREMENTSATYP.6"MIN.WOOD FRAMING ABOVE BY OTHERS12"Ø x 10" LONG ANCHORBOLTS (7" MIN. EMBED)@ 72" O.C. MAX. OREQUIVALENT METALSTRAP ANCHORSSLOPE GRADE AWAYFROM FOUNDATIONOPTIONAL STEM WALLMINIMUM THICKNESS TOMATCH SILL PLATESILL PLATE TO MATCHFRAME WALL ABOVE16" MAX FOR 4" THICK STEM24" MAX. FOR 6" THICK STEMSLAB-ON-GRADE BY OTHERS(1) #4 x CONTINUOUSHORIZONTAL BAR ATTOP OF WALL6" MIN. C.I.P. CONCRETEFOUNDATION WALLUNREINFORCED CONCRETESTRIP FOOTING SEE 5/F1#4x2'-0" DOWELS @ 72" O.C. MAX(5" MIN. EMBED) DOWELS ARENOT REQUIRED IF BACKFILL ISPLACED EQUALLY ON BOTHSIDES IN LIFTS NOT TO EXCEED24"-ALTERNATE EACH SIDE6"MIN.6'-0" MAX WOOD FRAMINGABOVE BY OTHERS12"Ø x 10" LONG ANCHORBOLTS (7" MIN. EMBED)@ 72" O.C. MAX. OREQUIVALENT METALSTRAP ANCHORSSLOPE GRADE AWAY FROMFOUNDATION AT A GRADUAL 2%SLOPE PER GENERAL NOTE 6SILL PLATE TO MATCHFRAME WALL ABOVE#4 x CONTINUOUS HORIZONTALBARS @ 24" O.C. TYP.OPTIONAL 2" RIGID INSULATION ONINSIDE FACE AND UNDERSLAB-ON-GRADE FOR 24" MIN.UNREINFORCED CONCRETESTRIP FOOTING SEE 5/F1(DROP FOR FROST ASREQUIRED PER SITE DESIGN)#4x2'-0" DOWELS @ 48" O.C.MAX (5" MIN. EMBED)(1) #4 x CONTINUOUS HORIZONTALBAR AT TOP OF WALLOPTIONAL SLAB LEDGECONCRETE SLAB-ON-GRADE8" MIN. C.I.P. CONCRETEFOUNDATION WALL#4x4'-0" HOOKS @ 24" O.C. BENT ORDRILLED AND EPOXY GROUTED3'-0"1'-0 " NO HOOKS @ 3'-0" OR LESS GRANULAR MATERIAL (SAND)DETAIL ABOVE MAY ONLY BE UTILIZED FOR A LENGTH OF 15'-0"#5 VERTICAL BARS @ 24" O.C.CENTERED IN WALL TO AID INTHE REDUCTION OF CRACKINGAND BACKFILLING ISSUES PRIORTO TOP OF WALL PINNINGCONTRACTOR IS TO PROVIDETEMPORARY TOP OF WALLBRACING UNTIL GARAGESLAB-ON-GRADE IS IN PLACE(HOOKS INTO GARAGE SLABPROVIDE REQUIRED TOP OFWALL LATERAL SUPPORT) CLEAR HEIGHT BACKFILL HEIGHT112" CLEARUNREINFORCED CONCRETE STRIPFOOTING PER CODE OR BY BUILDINGDESIGNER, AS AN ALTERNATIVE GUIDEUSE TABLE SHOWN AT LEFT8" MIN. C.I.P. CONCRETEFOUNDATION WALL-SEEREBAR TABLE 6/F1 FORVERTICAL REBARANCHOR BOLTS SEE WALLANCHOR INFO ON 2/F2FLOOR TO SILLCONNECTION SEE 1/F2WOOD FLOORSYSTEM BY OTHERSSLOPE GRADE AWAYFROM FOUNDATION2x6 MIN SILL PLATECLEAR HEIGHT OF 8'-0" OR LESS(2)#4xCONT. HORIZONTAL BARSCLEAR HEIGHT OF 8'-0" OR MORE(3)#4xCONT. HORIZONTAL BARSGENERAL STRIP FOOTING SIZE GUIDEONE-STORYSTRUCTURE16" WIDE x 8" THICK20" WIDE x 8" THICKTWO-STORYSTRUCTURE20" WIDE x 8" THICK26" WIDE x 8" THICK2000 PSFSOIL1500 PSFNOTE: TABLE ABOVE IS A GENERAL FOOTING SIZE GUIDE THAT SHOULD BE VERIFIED BY HOMEDESIGNER AND IS BASED ON 25'-0" FLOOR SPANS & 50'-0" ROOF SPANSCONCRETESLAB-ON-GRADEPLACED TIGHT TOFOUNDATION WALL6"MIN.3'-0" MAX GRADE HEIGHT ABOVE TOP OF SLAB#4 x 2'-0" DOWELS (5" MIN.EMBED) CENTERED IN WALL @48" O.C. (SAND SOIL)OR 36" O.C. (SANDY-CLAY SOIL)OR 24" O.C. (CLAY SOIL)DOWELS MUST BE WET SET ORDRILLED AND EPOXY GROUTED6" MIN. THICK C.I.P.CONCRETEFOUNDATION WALLSLOPE GRADE AWAYFROM FOUNDATION12"Ø x 10" LONG ANCHORBOLTS (7" MIN. EMBED)@ 72" O.C. MAX. OREQUIVALENT METALSTRAP ANCHORS(1) #4 x CONTHORIZONTAL BARAT TOP OF WALLFRAMING & SILLPLATE BY OTHERSSLAB-ON-GRADEBY OTHERS#4x2'-0" DOWELS @ 72" O.C.MAX (5" MIN. EMBED)UNREINFORCED CONCRETESTRIP FOOTING SEE 5/F1(18" MIN WIDTH FOR CLAYBACKFILL OR 16" MIN WIDTH IF2'-6" MAX UNBALANCED BACKFILL)SCOPE OF DRAWINGS:THESE CAST-IN-PLACE CONCRETE FOUNDATION WALL GUIDELINE DRAWINGS ARE PREPARED ANDCERTIFIED BY THE HANSON GROUP IN COMPLIANCE WITH THE MINNESOTA RESIDENTIAL CODE. THESEDRAWINGS CONTAIN STRUCTURAL INFORMATION FOR USE IN THE CONSTRUCTION OF STANDARD C.I.P.CONCRETE FOUNDATIONS FOR TYPICAL RESIDENTIAL CONDITIONS. THIS INFORMATION IS RELEVANTTO THE CONCRETE CONTRACTOR, THE GENERAL CONTRACTOR, AND THE FRAMING CONTRACTOR.THESE DRAWINGS EXPIRE ON DECEMBER 31, 2020.D R Horton 20860 Kenbridge Court #100Lakeville, MN 55044 COPYRIGHT HANSON GROUP LLC 2020©DescriptionDateRevisionJanuary 1, 2020Project Number:Date:0.001F22Sheets: of2Print Name:Signed: License Number:Nick Hanson1-1-2046665Date:I hereby certify that this plan, specification or reportwas prepared by me or under my direct supervisionand that I am a duly Licensed Professional Engineerunder the laws of the State of Minnesota.CONNECTION INFOTOP OF WALL CONNECTION TOFLOOR SYSTEM1F2BRICK LEDGE INFO5F2WALL SECTIONAT WINDOW WELL LOCATIONS6F2STOOP INFO7F2WALL ANCHOR INFOANCHOR BOLT AND ALTERNATIVESPACING2F2BLOCKING DETAILFLOOR JOIST CONDITION3F2BLOCKING DETAILFLOOR TRUSS CONDITION4F2SITE ADDRESS:City:State:Zip:MN3407 Kilmer Lane NorthSuite 4Plymouth, MN 55441Tel 612-708-3572www.hansongroupmn.comVENEER ORSLAB-ON-GRADEBY OTHERSFOUNDATIONWALL SEE 5/F1WOOD FLOORSYSTEM BYOTHERSFRAMING BY OTHERS16" HIGH MAX x6" THICK MINSTEM6"MINWOOD FLOORSYSTEM BYOTHERSFRAMING BY OTHERS6" MIN THICK STEM#4 DOWELS @ 36" O.C.EMBEDDED 24" INTOLOWER WALLFOUNDATIONWALL SEE5/F1VENEER ORSLAB-ON-GRADEBY OTHERS12"VENEER ORSLAB-ON-GRADEBY OTHERSFOUNDATION WALLSEE 2/F1 OR 3/F1FRAMING BYOTHERS16" HIGH MAXx 4" THICK MINSTEMTHICKNESS TOMATCH SILLPLATE6"3'-0" MAX VENEER ORSLAB-ON-GRADEBY OTHERSFOUNDATION WALLSEE 4/F1SLAB-ON-GRADEFRAMING BYOTHERS6" MIN THICKSTEMDETAIL @ HIGH GRADESIM @ NON-BEARINGDETAIL @ LOOKOUTSIM @ FROST WALLDETAIL @ FROST WALLSw/ LOW GRADEDETAIL @ LOW GRADESIM @ NON-BEARING112"CLEARMINMAX#4 DOWELS @36" O.C.EMBEDDED 24"INTO LOWERWALL (CENTERIN STEMWALL)6"12"Ø ANCHOR BOLTS w/ NUT & 18" THICKx 2"Ø OR SQUARE WASHER SEE 2/F2FOR SPACING (7" EMBED MIN)-METAL STRAP ANCHORS TO BEINSTALLED AT MANUFACTUREREQUIVALENT SPACINGFLOOR SYSTEM, TYPE,SIZE, AND SPACING TO BEDETERMINED BY OTHERSRIM BOARD OR BRACINGMATERIAL BY OTHERS2x6 SILL PLATE MINIMUMFLOOR TO SILL CONNECTION ATEACH MEMBER SEE TABLE BELOWWASHER TO BE COUNTERSUNKFLUSH w/ TOP OF SILL PLATESEE FULL HEIGHT WALL SECTIONON 5/F1 FOR FOUNDATION WALLREQUIREMENTSSLOPE GRADE AWAYFROM FOUNDATIONMINTRUSS/JOIST CONNECTION FOR FULL HEIGHT WALLS****BACKFILL TYPECLEAR HEIGHT(SEE 5/F1)FLOOR MEMBERSPACING8'-0"9'-0"10'-0"16"19.2"A(4) 0.131"Ø x 3" TOP NAILS AT EACH MEMBERSAND(30 PSF/FT)SANDY CLAY(45 PSF/FT)CLAY(60 PSF/FT)24"16"19.2"24"16"19.2"24"AAAAAAABAABBBBBCCCDDDDDDDCCONNECTION A(4) 0.148"Ø x 3" TOP NAILS AT EACH MEMBERCONNECTION B(2) 0.131"Ø x 3" TOP NAILS & MECHANICAL CLIPS : SIMPSON A35/USP MPA1 OR USP LJC ATEACH MEMBERCONNECTION CCONNECTION D(2) 0.131"Ø x 3" TOP NAILS & MECHANICAL CLIPS : SIMPSON FWANZ* OR USP LJQ**OR (2) SIMPSON A35s***/(2) USP MPA1s*** AT EACH MEMBER12"Ø ANCHOR BOLT AND NON-BEARING WALL BLOCKING SPACING FOR FULL HEIGHT WALLS*ALTERNATIVE TO CODE TABLE R404.1.(1)BACKFILL TYPECLEAR HEIGHT(SEE 5/F1)BACKFILL HEIGHT(SEE 5/F1)8'-0"9'-0"10'-0"7'-6"7'-0"8'-6"8'-0"7'-0" OR LESS9'-6"9'-0"8'-0"7'-0" OR LESS72"* 12"Ø EPOXIED THREADED ROD w/ 6" EMBED MAY BE USED AT SPACING SHOWNSAND(30 PSF/FT)SANDY CLAY(45 PSF/FT)CLAY(60 PSF/FT)6'-0" OR LESS72"72"72"72"72"72"72"72"72"72"72"72"48"60"72"48"60"72"36"48"72"36"36"72"72"72"48"24"24"ALTERNATIVE ANCHOR SPACING FOR FULL HEIGHT WALLS**ALTERNATIVE TO CODE TABLE R404.1.(1)BACKFILL TYPECLEAR HEIGHT(SEE 5/F1)BACKFILL HEIGHT(SEE 5/F1)8'-0"9'-0"10'-0"7'-6"7'-0"8'-6"8'-0"7'-0" OR LESS9'-6"9'-0"8'-0"7'-0" OR LESS48"** APPLIES TO MAB 15/FA1, MAB23/FA2, MAS/FA3, 12"Ø EXPANSION BOLT w/ 6" EMBED,12"Ø SELF-CUTTING ANCHOR BOLT w/ 4" EMBED, OR SIMPSON FWAZ ANCHORSAND(30 PSF/FT)SANDY CLAY(45 PSF/FT)CLAY(60 PSF/FT)6'-0" OR LESS60"72"30"36"72"18"24"42"72"72"24"18"20"24"18"24"24"30"42"16"12"14"16"12"16"36"36"N/AN/A10'-0" MAX TO T.O.S. 1'-8" MAX FLASHING & WOODPROTECTION BYOTHERSFLOOR FRAMING ORBLOCKINGFLOORCONNECTIONSEE 1/F2 &2/F2C.I.P. CONCRETEWALL SEEADJACENTPLANS FORTHICKNESS &MAXIMUM WALLLENGTHSSEE FULLHEIGHT WALLSECTION 5/F1FORREINFORCINGSTOOPSLAB BYOTHERS13'-6" @ 10" WALL3'-0" MIN.10'-6" @ 8" WALL13'-6" @ 10" WALL3'-0" MIN.10'-6" @ 8" WALL13'-6" @ 10" WALL10'-6" @ 8" WALL13'-6" @ 10" WALL3'-0" MIN.10'-6" @ 8" WALL13'-6" @ 10" WALL10'-6" @ 8" WALL3'-0" FULL HEIGHT BASEMENTMIN FULL HEIGHT FULL HEIGHT EXAMPLE CORNEROR STRAIGHT WALLOPTIONS -TYPSTOOP AREA8" MIN C.I.P. CONCRETEWALL SEE FULL HEIGHTWALL SECTION 5/F1NOTES:1.ADD RETURN WALLS OR BUTTRESSES IN STOOP AREA AS SHOWN IF OVERALL STOOP CENTER TO CENTERWIDTH EXCEEDS DIMENSIONS SHOWN.2.STOOP WALLS REQUIRE MINIMUM 16" WIDE x 8" DEEP CONCRETE STRIP FOOTING.EXAMPLE '1'EXAMPLE '2'EXAMPLE '3'SLOPE GRADEAWAY FROMFOUNDATIONSLOPE GRADEAWAY FROMFOUNDATIONSLOPE GRADEAWAY FROMFOUNDATIONSLOPE GRADEAWAY FROMFOUNDATIONNOTE: INCREASE STRIP FOOTING WIDTH AT ALL WALLS SUPPORTING MORE THAN 6'-0" OF VENEER.WIDTH TO INCREASE BY THICKNESS OF VENEER MULTIPLIED BY NUMBER OF STORIES.TYP * FWANZ TO BE USED WITH A MIN. 118" OSB RIM AND LOCATED w/IN 5" OF EACH MEMBER. WITH FLOOR TRUSSES,FWANZ MUST BE IN CONTACT WITH A TRUSS OR A MINIMUM 2x4 CONTINUOUS BOTTOM BRACE MUST BE IN PLACE.** LJQ IS TO BE APPROPRIATELY SIZED BASED ON MEMBER WIDTH.*** MEMBER MUST BE A MINIMUM OF 3" WIDE FOR PLACEMENT OF (2) SIMPSON A35s/(2) USP MPA1s.****CONNECTIONS ARE CLASSIFIED A TO D, WITH D BEING THE STRONGEST. IT IS ACCEPTABLE TO USE ASTRONGER CLASS CONNECTION THAN NOTED IN THE TABLE ABOVE.2x8 SILL PLATE TO BE USED w/MAXIMUM OF 112" OVERHANG(MAINTAIN 234" EDGE DISTANCETO BOTH CONCRETE AND INSIDEOF SILL PLATE) - VERTICAL LOADTRANSFER BY SUPPLIERBACKFILL BELOWEXTERIOR STOOP SLABSWITH COMPACTEDGRANULAR MATERIALTO FROST DEPTH(4'-0" MINIMUM)NAIL SHEATHING TO BLOCKING/JOISTS0.131 Ø x 3" LONG NAILS @ 6" O.C.STRUCTURAL RIM BOARD BY OTHERSTYPE D CONNECTOR@ BLOCKING SEE 1/F22 x 6 MINSILL PLATEFOUNDATION WALL SEE OTHER SHEETSFOR ANCHORS & WALL INFOSLOPE GRADE AWAY FROMFOUNDATIONIF REQUIRED, PROVIDE 2 x 4 MINSPACERS UNTIL SPACES IN WHICH FULLHEIGHT BLOCKING CAN BE INSTALLED,TOE NAIL TO FLOOR MEMBERS EACH ENDw/ (12) 0.131"Øx3" LONG NAILSFRAMINGBY OTHERSOPTIONAL OPEN SPACE AS SHOWNOR SHIFT FULL HEIGHT BLOCKINGPROVIDE BLOCKINGAS REQUIRED TO ACHIEVENAILING SHOWN. (MIN 2SPACES) BLOCKING HEIGHTTO MATCH JOIST DEPTH &BE OF LUMBER, I-JOIST, OROTHER MANUFACTUREDMATERIAL ATTACHBLOCKING TO JOISTS w/ TOENAILS EACH ENDJOISTS BY OTHERSSEE 2/F2 FOR SPACING OFBLOCKING SYSTEM SHOWNNOTES:1.MAIN LEVEL FLOOR SHEATHING TO BE 34" PLYWOOD/OSB PLACED IN STAGGERED PATTERN NAILED w/ 0.131"Ø x3" LONG NAILS @ 6" O.C. AT PANELS EDGES & @ 12" O.C. @ PANEL INTERIOR SUPPORTS OF EQUIVALENT.2.NAILS IN BLOCKING ARE TO BE PLACED SUCH THAT THE WOOD DOES NOT SPLIT.3.BLOCKING MEMBERS SHOWN MAY BE REPLACED WITH PRE-MANUFACTURED TRUSS STYLE OR FULL DEPTHMEMBER BLOCKING SUCH AS I-JOIST OR LVL DESIGNED FOR 1,500 POUND LATERAL COMPRESSIVE LOAD.NAILING SHOWN IS TO BE USED AT MINIMUM.4.BLOCKING DOES NOT HAVE TO BE PLACED IN ADJACENT BAYS. IF REQUIRED USE ADDITIONAL 2x4 SPACERS ASSHOWN IN FIRST SPACE.5.HOLES MAY BE INSTALLED IN BLOCKING IF REQUIRED UP TO 4" IN DIAMETER, MAINTAIN 3" EDGE DISTANCE.NAIL SHEATHING TO BLOCKING/TRUSSESw/ (12) 0.131"Øx3" LONG NAILSDUCT/MECHANICAL (AS REQUIRED)BY OTHERSFRAMINGBY OTHERS0.131 Ø x 3" LONGNAILS @ 6" O.C.RIM TRUSSBY OTHERSTOP NAIL RIM TO SILLw/ MIN OF (12)0.131 Ø x3" LONG NAILS EACHSIDE OF BLOCKING ORTYPE D CONNECTOR @BLOCKING SEE 1/F22 x 6 MINSILL PLATEFOUNDATION WALL SEEOTHER SHEETS FORANCHORS & WALL INFOSLOPE GRADE AWAYFROM FOUNDATIONIF REQUIRED, PROVIDE 2 x 4 MIN SPACERSTOP & BOTTOM AT MECHANICAL UNTILSPACES IN WHICH BLOCKING CAN BEINSTALLED, TOE NAIL TO FLOOR MEMBERSw/ (2) 0.131 Ø x 3" LONG NAILS3/4" PLYWOOD/OSB ONE SIDEOF BLOCKING w/ (6) 0.131 Ø x 3" LONG NAILS TOP & BOTTOMOR 1/2" PLYWOOD/OSB EACHSIDE OF BLOCKING EACH w/(4) 0.131 Ø x 3" LONG NAILS TOP & BOTTOMPROVIDE 2 x 4 MIN BLOCKINGTOP & BOTTOM OF TRUSSESAS REQUIRED TO ACHIEVENAILING SHOWN.INSTALL w/ (2) 0.131 Ø x 3"LONG TOE NAILSTRUSSES BY OTHERSNOTES:1.MAIN LEVEL FLOOR SHEATHING TO BE 34" PLYWOOD/OSB PLACED IN STAGGERED PATTERN NAILED w/ 0.131"Ø x 3"LONG NAILS @ 6" O.C. AT PANELS EDGES & @ 12" O.C. @ PANEL INTERIOR SUPPORTS OF EQUIVALENT.2.NAILS IN BLOCKING ARE TO BE PLACED SUCH THAT THE WOOD DOES NOT SPLIT.3.BLOCKING MEMBERS SHOWN MAY BE REPLACED WITH PRE-MANUFACTURED TRUSS STYLE OR FULL DEPTH MEMBERBLOCKING SUCH AS I-JOIST OR LVL DESIGNED FOR 1,500 POUND LATERAL COMPRESSIVE LOAD. NAILING SHOWN IS TOBE USED AT MINIMUM.4.BLOCKING DOES NOT HAVE TO BE PLACED IN ADJACENT BAYS. IF REQUIRED USE ADDITIONAL 2x4 SPACERS ASSHOWN IN FIRST SPACE.5.HOLES MAY BE INSTALLED IN BLOCKING IF REQUIRED UP TO 4" IN DIAMETER, MAINTAIN 3" EDGE DISTANCE.SEE 2/F2 FOR SPACING OFBLOCKING SYSTEM SHOWN10'-0" MAX 3'-8" MAX 2'-6" MIN OPENING 1'-6" MIN 3'-0" EACH WAY MIN112" TYP SLOPE GRADE AWAYFROM FOUNDATION#4 HORIZONTAL BARS @12" O.C. CENTERED INWALLS LAP AROUNDCORNERS AND HOOKINTO FOUNDATION WALL@ EACH SIDE (REFER TO5/F1 FOR HORZ. BARREQUIREMENTS w/ 8"C.I.P. WALLS)6" MIN C.I.P.CONCRETE WALL#4 VERTICAL BARS @EACH OUTSIDECORNER OF WELL(1)#4 x2'-0" DOWEL @EACH OUTSIDECORNER OF WELL (5"MIN EMBED)12" WIDE x 8" THICK MINSTRIP FOOTING(1) #4 HORIZONTALBAR AT TOP OF WALL(2) #4 HORIZONTAL BARSTOP & BOTTOM OFLINTEL EXTEND 24" MINPAST OPENING EACHEND (WOOD OR STEELOPTION BY OTHERS)WALL BEYONDPLACE (2) #4 VERTICALBARS FULL HEIGHT ANDONE ANCHOR w/IN 12" OFOPENING EACH END8" MIN C.I.P.CONCRETE WALLSLAB-ON-GRADEUNREINFORCED CONCRETESTRIP FOOTING SEE FULLHEIGHT WALL SECTION 5/F1LOOKOUTWALLSEE 3/F1GRANULARMATERIAL(SAND)SLOPEWINDOW WELLLADDER/ESCAPEMEANS BYOTHERS5'-0" EACH WAY MAXFLOOR SYSTEM BY OTHERS(DO NOT PLACE GIRDERS ORBEAMS OVER CONCRETE LINTELDESIGNED FOR 1500 PLF)IF CONCRETEOPTIONAL RIGID INSULATION w/IN WINDOW WELL ATTHE DISCRETION OF THE BUILDER FOR ADDITIONALFROST PROTECTION AS REQUIRED PER SITE DESIGN6"MIN.A SECTION AD R Horton 20860 Kenbridge Court #100Lakeville, MN 55044 ProductsPlotID Net Qty ProductLength PliesB1 2 1-3/4" x 7-1/4" VERSA-LAM® 2.0 3100 SP 20' 0" 2B2 2 1-3/4" x 9-1/2" VERSA-LAM® 2.0 3100 SP 10' 0" 2B3 8 1-3/4" x 9-1/2" VERSA-LAM® 2.0 3100 SP 8' 0" 2B4 2 1-3/4" x 11-7/8" VERSA-LAM® 2.0 3100 SP 20' 0" 2B5 1 Beam by others 6' 0" 1B6 6 Beam by others 4' 0" 1Pt1 2 Post by others 8' 0" 1PORCH FRAMINGBY OTHERSLOWERFLOORUPPERFLOORSTAIRWAYSTAIRWAYSINGLETRIMMERSSINGLETRIMMERSSINGLETRIMMERSROOF TRUSSESBY OTHERSROOF TRUSSESBY OTHERSROOF TRUSSESBY OTHERSSINGLETRIMMERSSINGLETRIMMERSPt1Pt1B1B4B2B3B6B6B3B3B3B6B6B6B6B59' 11"40' 8"57' 0" 2' 0" 21' 0" 34' 0" 19' 0" 19' 0" 11' 0" 49' 0" 6' 5"ROOF TRUSSESBY OTHERSPORCH FRAMINGBY OTHERSSAME PORCH HEADER ASELEVATION "A" BUT THEPOST LOCATIONSCHANGE SLIGHTLY.19' 0" 19' 0" 21' 0" 2' 0" 11' 0" 9' 11" 6' 5"PORCH FRAMINGBY OTHERSSAME PORCH HEADER ASELEVATION "A" BUT THEPOST LOCATIONSCHANGE SLIGHTLY.ROOF TRUSSESBY OTHERSROOF TRUSSESBY OTHERSGIRDER BY OTHERS21' 0" 11' 0" 9' 11"19' 0" 19' 0" 2' 0" 6' 5"Sheet: 3 of 3DWG: Roof HeadersFile: Plan #3035By: Anthony EstevezDate: 6-19-19Scale: 1/4" = 1' - 0"BC FRAMERD.R. HORTONBoise Building Material DistributionLakeville, MN (952) 469-5900SALES PRESENTATION DRAWINGNo structural or dimensional check has been made of this designdrawings of the building, therefore purchaser is to check andapprove all dimsensions, quantities, loads, and details carefully.This drawing has not been check by Boise Engineering.NOTE:ALL MEASUREMENTSTO BE VERIFIEDIN THE FIELD.9-12-19AE8-9-19AERevisions:BY:"BEAM BY OTHERS" TO BE ADOUBLE 2X10 SPF #2SUPPLIED BY OTHERS,UNLESS NOTED OTHERWISE.NOTE:ALL HEADERS REQUIRE NOLESS THAN 3" OF BEARINGAT EACH END. UNLESSNOTED OTHERWISE.PLAN #3035-GLD.R. HORTONROOF HEADERSDESIGN = L/360ELEVATION "A"ROOF HEADERSELEVATION "B"ELEVATION "C" COPYRIGHT HANSON GROUP, LLC 2020©THIS SHEET/S REPRESENTS A COMPLETE DESIGN OF THE "MAIN WINDFORCE RESISTING SYSTEM" FOR THE ENTIRERESIDENTIAL STRUCTURE. THE LOCATION AND LENGTH OF EACH BRACED WALL PANEL AND ENGINEERED WINDRESISTING ELEMENT THAT IS REQUIRED FOR THE HANSON GROUP'S DESIGN IS SHOWN ON THE STRUCTURALDRAWINGS. WALLS NOT SPECIFICALLY LABELED ON THE PLANS MAY BE STANDARD FRAMING.SECTIONS SHOWN DEPICT CONNECTIONS OF BRACED WALL PANELS TOROOF TRUSSES ABOVE, TO JOISTS/TRUSSES/BLOCKING ABOVE, AND TOJOISTS/TRUSSES/BLOCKING BELOW. THESE PANELS ARE NOT NECESSARILYREQUIRED TO ALIGN, BUT MAY DEPENDING ON PLAN LAYOUT.ROOFTRUSSESBRACEDWALL PANELFLAT 2x6 @ 24" O.C.(MIN. (3) PER BRACEDWALL PANEL)SIMPSONA35FRAMINGANGLEEACH END(4) 0.131"Øx 3" NAILSPROVIDE 12" WIDTH WEBSTIFFENER FOR ATTACHMENTOF FRAMING ANGLEBRACEDWALL PANEL(4) 0.131"Øx 3" NAILSSIMPSONA35FRAMINGANGLEEACH ENDFLOORJOISTSPROVIDE 12" WIDTH WEBSTIFFENER FOR ATTACHMENTOF FRAMING ANGLEBRACEDWALL PANEL(4) 0.131"Øx 3" NAILSSIMPSONA35FRAMINGANGLEEACH ENDFLOORJOISTSBRACEDWALL PANEL(4) 0.131"Øx 3" NAILSSIMPSONLTP4FRAMINGPLATEEACH ENDFLOORTRUSSESFLAT 2x6 @ 24" O.C.(MIN. (3) PER BRACEDWALL PANEL)FLAT 2x6 @ 24" O.C.(MIN. (3) PER BRACEDWALL PANEL)FLAT 2x6 @ 24" O.C.(MIN. (3) PER BRACEDWALL PANEL)BRACEDWALL PANEL(4) 0.131"Øx 3" NAILSSIMPSONLTP4FRAMINGPLATEEACH ENDFLOORTRUSSESFLAT 2x6 @ 24" O.C.(MIN. (3) PER BRACEDWALL PANEL)BRACED WALL CONNECTIONBRACED WALL CONNECTIONBRACED WALL CONNECTION(ROOF TRUSSES)(FLOOR JOISTS)(FLOOR TRUSSES)DETAILS SHOWN ABOVE AREALTERNATIVE CONNECTIONS TO BEUSED WHEN BRACED WALL PANELDOES NOT ALIGN WITH FRAMING.EXTERIOR NON-BEARING WALLFRAME 2x4 BOXAROUND SPACEBETWEEN TRUSS w/SAME SHEATHINGAND FASTENING ASWALL BELOW(OR REPLACE w/ADEQUATE DEPTH2x MEMBER)#12 x 312" WOODSCREWS @ 16" O.C.INSTALLED INADDITION TO NAILS(MAIN/UPPERLEVEL ROOFTRUSS BEARINGWALLS ONLY)#12 x 312" WOODSCREWS @ 16" O.C.INSTALLED INADDITION TO NAILS(MAIN/UPPERLEVEL ROOFTRUSS BEARINGWALLS ONLY)EXTERIOR BEARING WALLREPRESENTSFIGURER602.10.8.2(3)INDICATES INTERIOR BRACED WALL PANEL w/ GYPSUMSHEATHING BOTH FACES WITH EITHER FASTENER OPTIONLISTED IN NOTE 3, SPACED AT 4" O.C. PROVIDE INCREASEDFASTENING REQUIREMENTS AS SHOWN BELOW.INDICATES ENGINEERED WIND RESISTING ELEMENTS TOBE CONSTRUCTED AS SHOWN IN THE DETAIL SHEETS.(MIN. LENGTH)INDICATES EXTERIOR BRACED WALL PANEL w/ SHEATHING ONEXTERIOR FACE IN ACCORDANCE w/ NOTE 2. PROVIDEINCREASED FASTENING REQUIREMENTS AS SHOWN BELOW.(MIN. LENGTH)w/ JOISTSw/ TRUSSESw/ JOISTSw/ TRUSSESw/ JOISTSw/ TRUSSESw/ JOISTSw/ TRUSSESMATERIALSWALL STUDS (10' OR LESS):SPF STUD GRADE OR BETTERWALL STUDS (OVER 10'):SPF NO.2 GRADE OR BETTERDIMENSIONAL LUMBER:SPF NO.2 GRADE OR BETTERTREATED LUMBER:SYP NO.2 GRADE OR BETTERLSL:134" WIDTH - 1.55E OR BETTERLVL:134" WIDTH - 1.9E OR BETTERLOADSROOF SNOW LOAD: 35-42 PSFROOF DEAD LOAD: 15 PSFFLOOR LIVE LOAD: 40 PSFFLOOR DEAD LOAD: 15 PSFWIND LOAD:115 MPH ULTIMATE EXP. BCODE2020 MINNESOTA RESIDENTIAL CODEHARDWAREALTERNATETABLESIMPSONPRODUCTUSPPRODUCTA34MP34A35MPA1H2.5RT7HTT5HTT45LSTASTRAPSAMELTP4MP4FMSTCSTRAPSAMESTHD14/RJSTAD14/RJTITEN HDWEDGEBOLTHARDWARE IN SAMEROW MAY BE USEDINTERCHANGEABLYIN THIS DOCUMENTROOF TRUSSESFASTENED TO PLATESw/ (4) 0.131"Ø x 3"TOENAILS & SIMPSONH2.5 CLIPNAIL BOTTOM PLATETO RIM/JOIST/BLOCKING w/ (3) 16dNAILS EVERY 16"NAIL BOTTOM PLATETO RIBBON BRACE /TRUSS w/ (3) 16dNAILS EVERY 16"NAIL EACH JOIST TOTOP PLATES w/ (3)0.131"Ø x 3" NAILS2x4 BLOCKINGBETWEENTRUSSES NAILEDTO TOP PLATESw/ (3) 0.131"Ø x 3"NAILS EACHNAIL EACH TRUSS TOTOP PLATES w/ (3)0.131"Ø x 3" TOENAILSROOF TRUSSFASTENED TOPLATES w/0.131"Ø x 3"TOENAILS@ 6" O.C.NAIL BOTTOMPLATE TO RIM/JOIST/BLOCKINGw/ (3) 16d NAILSEVERY 16"NAIL RIM TOPPLATES w/0.131"Ø x 3"TOENAILS@ 6" O.C.NAIL BOTTOMPLATE TO LADDERTRUSS w/ (3) 16dNAILS EVERY 16"NAIL LADDERTRUSS TO TOPPLATES w/0.131"Ø x 3"NAILS @ 6" O.C.INTERIOR WALLPERPENDICULAR TO FRAMINGINTERIOR WALLPARALLEL w/ FRAMING2x4 BLOCKING BETWEENROOF TRUSSES NAILEDTO TOP PLATES w/ (3)0.131"Ø x 3" NAILS EACHNAIL BOTTOM PLATE TOBLOCKING w/ (3) 16dNAILS EVERY 16"PROVIDE FULL DEPTHBLOCKING BETWEEN JOISTSNAILED TO TOP PLATES w/(3) 0.131"Ø x 3" NAILS EACHNAIL EACH JOIST TO TOPPLATE w/ (3) 0.131"Ø x 3" NAILSNAIL BOTTOM PLATE TOBLOCKING w/ (3) 16dNAILS EVERY 16"PROVIDE FULL DEPTHBLOCKING BETWEEN TRUSSESNAILED TO TOP PLATES w/(3) 0.131"Ø x 3" NAILS EACHNAIL EACH TRUSS TO TOP PLATEw/ (3) 0.131"Ø x 3" TOENAILSPROVIDE ROOF TRUSSDIRECTLY IN LINE w/BRACED WALL PANELFASTENED TO PLATESw/ 0.131"Ø x 3"TOENAILS @ 6" O.C.NAIL BOTTOM PLATETO BLOCKING w/ (3)16d NAILS EVERY 16"PROVIDE JOIST DIRECTLYIN LINE w/ BRACED WALLPANEL FASTENED TOPLATES w/ 0.131"Ø x 3"TOENAILS @ 6" O.C.NAIL BOTTOM PLATETO BLOCKING w/ (3)16d NAILS EVERY 16"PROVIDE TRUSS DIRECTLYIN LINE w/ BRACED WALLPANEL FASTENED TOPLATES w/ 0.131"Ø x 3"TOENAILS @ 6" O.C.DescriptionApril 8, 2020Project Number:Date:0.145S11Sheets: of1D R Horton 20860 Kenbridge Court #100Lakeville, MN 550443035-C-GL ModelMinnesota Construction3407 Kilmer Lane NSuite 4Plymouth, MN 55441Tel 612-708-3572www.hansongroupmn.comPLANS SHOWN LIGHT IN BACKGROUND ARE FORLOCATION REFERENCE ONLY. PLAN NOTES ANDELEMENTS SHOWN LIGHT MAY NOT NECESSARILYSUPPORT THE HANSON GROUP'S DESIGN.DateRevisionPrint Name:Signed: License Number:Ryan Mack4-8-2046673Date:I hereby certify that this plan, specification or reportwas prepared by me or under my direct supervisionand that I am a duly Licensed Professional Engineerunder the laws of the State of Minnesota.SCOPEDESIGN AND DETAIL OF THE MAIN WINDFORCE RESISTING SYSTEM FOR A SINGLE-FAMILY RESIDENCE. CONSTRUCTION ISTO BE IN ACCORDANCE WITH THIS DOCUMENT, STANDARD INDUSTRY PRACTICE, AND THE CODE.NOTES1.THESE DOCUMENTS APPLY TO STRUCTURAL ONLY. REFER TO CONSTRUCTION DOCUMENTS FOR MORE INFORMATION.2.ALL EXTERIOR WALLS ARE TO BE CONSTRUCTED IN ACCORDANCE WITH THE FOLLOWING CRITERIA, U.N.O., WHICHMEETS OR EXCEEDS THE REQUIREMENTS OF CODE SECTION R602.10.4-WSP AND CS-WSP.A.2x6 STUDS SPACED @ 16" O.C.B.EXTERIOR SHEATHING: 716" MIN. STRUCTURAL PANEL SHEATHING w/ 8d COMMON NAILS @ 6" O.C AT PANEL EDGESAND 12" O.C. AT INTERMEDIATE SUPPORTS OR 134" 16 GAUGE STAPLES @ 3" / 6" SPACING.3.ALL INTERIOR WALLS ARE TO BE CONSTRUCTED IN ACCORDANCE WITH THE FOLLOWING CRITERIA, U.N.O.A.2x4 OR 2x6 STUDS SPACED @ 16" O.C.B.WALL SHEATHING: 12" MIN. GYPSUM SHEATHING FASTENED TO FRAMING w/ 5d COOLER NAILS @ 8" O.C. MAX. ORTYPE S/W WALLBOARD SCREWS @ 16" O.C. MAX. (58" MINIMUM STUD PENETRATION)4.ALL FLOORS ARE TO BE CONSTRUCTED IN ACCORDANCE WITH THE FOLLOWING CRITERIA.A.FLOOR FRAMING SPACED AT A MAXIMUM OF 24" O.C.B.FLOOR SHEATHING: 34" STRUCTURAL PANEL SHEATHING w/ 8d COMMON NAILS @ 6" O.C AT PANEL EDGES AND 12"O.C. AT INTERMEDIATE SUPPORTS.5.ALL ROOFS ARE TO BE CONSTRUCTED IN ACCORDANCE WITH THE FOLLOWING CRITERIA.A.ROOF FRAMING SPACED AT A MAXIMUM OF 24" O.C.B.FASTEN ALL ROOF FRAMING TO TOP PLATES WITH SIMPSON H2.5 CLIP OR EQUIVALENT AND (4) 0.131"Ø x 3"TOENAILS.C.ROOF SHEATHING: 12" STRUCTURAL PANEL SHEATHING w/ 8d COMMON NAILS @ 6" O.C AT PANEL EDGES AND 12"O.C. AT INTERMEDIATE SUPPORTS OR 134" 16 GAUGE STAPLES @ 3" / 6" SPACING.6.ALONG LENGTH OF WALLS, LAP WALL TOP PLATES A MINIMUM OF 24" AND FASTEN TOGETHER WITH (12) 0.131"Ø x 3" INLAP ZONE. AT CORNERS AND INTERSECTIONS, LAP PLATES AND PROVIDE (3) 0.131"Ø x 3" FACE NAILS.7.CONNECTIONS NOT SPECIFICALLY NOTED ARE TO BE IN ACCORDANCE WITH CODE TABLE R602.3(1).8.TALL WOOD WALL FRAMING IS TO BE DESIGNED BY SUPPLIER FOR GRAVITY AND OUT-OF-PLANE WIND LOADS.9.THE ENTRY PORCH IS CONSIDERED TO BE A PRIMARILY OPEN, NON-ESSENTIAL PORTION OF THE STRUCTURE AND ISEXCLUDED FROM THE OVERALL MAIN WINDFORCE SYSTEM OF THE HOME. PROVIDE CODE REQUIRED UPLIFTCONNECTIONS AT ALL POSTS AND TENSION CONNECTIONS AT LEDGERS.MAIN LEVEL HOUSE PLAN SHOWNFOR LOCATION REFERENCE ONLY2S1REFERENCE PLANCONSTRUCTPORTAL FRAMEAS SHOWN IN 3/S1CONCRETEFOUNDATIONBELOWSIMPSON HTT5HOLDOWN ANCHOR ATLOCATIONS SHOWN w/12"Ø x 12" LONGSIMPSON TITEN HDSCREW-IN ANCHORPOST-INSTALLED HOLDOWN OPTION4S1FRAMING DETAILPARTIAL LOWER LEVEL HOUSE PLANSHOWN FOR LOCATION REFERENCE ONLY1S1REFERENCE PLANTHE REQUIREMENTS SHOWN DIRECTLY ABOVE ONLY APPLY TO WALKOUT FOUNDATIONS(4-FT)(4-FT)(4-FT) (4-FT)(4-FT)(4-FT) (4-FT)(4-FT) (4-FT) ONE-SIDED (4-FT) ONE-SIDED (4-FT)(4-FT)(3.5-FT)(4-FT)(4-FT)(4-FT)(4-FT)(3.5-FT)(5-FT)(5-FT)(7-FT)ONE-SIDED(7-FT)ONE-SIDED(7-FT) ONE-SIDED (7-FT) ONE-SIDED BRACED WALL LINE BRACED WALL LINE BRACEDWALL LINEBRACEDWALL LINE(4-FT)(4-FT)(4-FT)(4-FT)(5-FT)ONE-SIDED(5-FT)ONE-SIDEDBRACED WALL LINE BRACED WALL LINE BRACED WALL LINE BRACEDWALL LINEBRACEDWALL LINEBRACEDWALL LINES1FRAMING DETAILGARAGE FRONT PORTAL FRAME3NOTEINFO APPLIES SYMMETRICALLY ACROSS DETAIL.16'-3"±NOT TO EXCEED 12'-0"FASTEN TOP PLATE TO HEADER w/ (2)ROWS 16d SINKER NAILS @ 3" O.C.(1) 2x6 BEARING STUD & (1) 2x6 FULLHEIGHT STUD EACH END OF HEADERLOCATE PANEL JOINT WITHIN 2'-0" FROMCENTER OF HEADER HEIGHT AS REQ'D (2x SOLIDBLOCKING REQUIRED AT SHEATHING JOINT)(2) 2x6 BEARING STUDS MIN.(VERIFY w/ SUPPLIER)PROVIDE 2x6 INFILL WALLABOVE HEADER AS REQ'DSIMPSON STHD14 EMBEDDED HOLDOWNANCHOR AT LOCATIONS SHOWN(REFER TO 4/S1 FOR ALTERNATIVE OPTION)FOUNDATION WALL BELOWLENGTH OF CONTINUOUS HEADER58" Ø ANCHOR BOLT (7" MIN. EMBED)w/ 2" x 2" x 316" PLATE WASHERNAIL SHEATHING TO HEADER w/ 8dNAILS @ 3" O.C. EA. WAY TYP.SMALL HATCH AREA INDICATES 716" ORTHICKER PLYWOOD OR OSB SHEATHINGAPPLIED TO EXTERIOR SIDE OF STUDS(NAIL SHEATHING AROUND PERIMETER w/ (2)ROWS 8d NAILS @ 3" O.C. STAGGERED & TOPLATES / BLOCKING @ 3" O.C.)SIMPSON MSTC40 STRAP ON INSIDE FACEOF WALL (PROVIDE SPACER TO FLUSHOUT HEADER TO WALL STUD THICKNESS)FASTEN KING STUD TO HEADER w/(2) ROWS 16d SINKER NAILS @ 3" O.C.LARGE HATCH AREA INDICATES 716" OR THICKERPLYWOOD OR OSB SHEATHING APPLIED TO EXTERIORSIDE OF STUDS w/ STANDARD 6"/12" NAILINGFASTEN FRAMING ABOVE AS SHOWNFOR BRACED WALL PANELS1'-412"±CONTINUOUS LSL/LVL HEADER TOSUPPORT VERTICAL LOADS BY SUPPLIER(MIN.312" WIDTH & MIN.1114" DEPTH REQ'D)1'-412"± 1 03-00-0004-00-00ST011 ST02KS01JS01CS01CS02CS03CS04CS05CS03CS06CS02JS02CS07KS02ST03ST04ST05ST06ST07ST08ST09ST10H01 H02 ST1114-00-00 08-01-0208-01-0211-00-022 Page 1 of 3 Wall Summary Information 3035-Kitchen(Left elevation) BC CALC®Member Report Wall |14-00-00 |16 OCS July 16,2019 10:11:22 Build 7192 Job name:File name:3000 Series Homes -Tall Wall (Kitchen Wall) Address:Description: City,State,Zip:Specifier: Builder:Designer: Code reports:ESR-1040 Company: Page 2 of 3 Wall Summary Information 3035-Kitchen(Left elevation) BC CALC®Member Report Wall |14-00-00 |16 OCS July 16,2019 10:11:22 Build 7192 Job name:File name:3000 Series Homes -Tall Wall (Kitchen Wall) Address:Description: City,State,Zip:Specifier: Builder:Designer: Code reports:ESR-1040 Company: Load Summary Live Dead Snow Wind Roof Live Tributary Tag Description Load Type Ref.Start End 100%90%115%160%125% 1 wind Unf.Area (lb/ft²)L 00-00-00 11-00-02 20 01-04-00 2 roof Unf.Lin.(lb/ft)L 00-00-00 14-00-00 80 140 01-04-00 Bearing Supports Size Value %Allowable Duration Material Top Plate Double 2x 401 lbs 11.4%115%Spruce-Pine-Fir Bottom Plate 2x 401 lbs 11.4%115%Spruce-Pine-Fir OpeningsTagDescription Distance Ref.Elevation Ref.Height Width Justification 1 Window 10-00-08 Right 07-00-00 Bottom 48"36"Top/Middle Member SummaryTagProduct Plies Results Connection ST01 1-1/2"x 5-1/2"VERSA-LAM®1.7 2650 SP 1 Passed KS01 1-1/2"x 5-1/2"VERSA-LAM®1.7 2650 SP 1 Passed KS02 1-1/2"x 5-1/2"VERSA-LAM®1.7 2650 SP 1 Passed H01 2 x 10 SPF #2 2 Passed H02 Plank 2 x 6 SPF #2 1 Passed Wall Framing Net Tag Qty Product Plies Length ST01,ST02 2 1-1/2"x 5-1/2"VERSA-LAM®1.7 2650 SP 1 12-00-00 ST03,ST04,ST05 3 1-1/2"x 5-1/2"VERSA-LAM®1.7 2650 SP 1 10-00-00 ST06,S...0,ST11 6 1-1/2"x 5-1/2"VERSA-LAM®1.7 2650 SP 1 08-00-00 KS01 1 1-1/2"x 5-1/2"VERSA-LAM®1.7 2650 SP 1 12-00-00 KS02 1 1-1/2"x 5-1/2"VERSA-LAM®1.7 2650 SP 1 10-00-00 JS01,JS02 2 2 x 6 SPF #2 1 08-00-00 CS01,C...3,CS04 6 2 x 6 SPF #2 1 04-00-00 CS05,C...6,CS07 3 2 x 6 SPF #2 1 02-00-00 H01 2 2 x 10 SPF #2 2 04-00-00 H02 1 2 x 6 SPF #2 1 04-00-00 BP01 1 1-1/2"x 5-1/2"Spruce-Pine-Fir 1 14-00-00 TP01 2 1-1/2"x 5-1/2"Spruce-Pine-Fir 2 13-00-00 TP02 2 1-1/2"x 5-1/2"Spruce-Pine-Fir 2 03-00-00 Fire blocking is not included.Estimated quantity:14'fire blocking. NotesBCCALC®considers gravity and out-of-plane lateral loading only.Wall bracing (braced wall panels)to resist in-plane lateral loading (parallel to wall)is the responsibility of the building designer. Lateral Deflection:User specified (L/180)Total load lateral deflection criteria Lateral Deflection:Arbitrary (1")Total load lateral deflection criteria Vertical Deflection:User specified (L/240)Total load deflection criteria Vertical Deflection:User specified (L/360)Live load deflection criteria Vertical Deflection:Arbitrary (1")Total load deflection criteria BC CALC®analysis is based on IBC 2009. Page 3 of 3 Wall Summary Information 3035-Kitchen(Left elevation) BC CALC®Member Report Wall |14-00-00 |16 OCS July 16,2019 10:11:22 Build 7192 Job name:File name:3000 Series Homes -Tall Wall (Kitchen Wall) Address:Description: City,State,Zip:Specifier: Builder:Designer: Code reports:ESR-1040 Company: DisclosureUseoftheBoise Cascade Software is subject to the terms of the End User License Agreement (EULA). Completeness and accuracy of input must be reviewed and verified by a qualified engineer or other appropriate expert to assure its adequacy,prior to anyone relying on such output as evidence of suitability for a particular application.The output here is based on building code-accepted design properties and analysis methods. Installation of Boise Cascade engineered wood products must be in accordance with current Installation Guide and applicable building codes.To obtain Installation Guide or ask questions,please call (800)232-0788 before installation. BC CALC®,BC FRAMER®,AJS™,ALLJOIST®,BC RIM BOARD™,BCI®,BOISE GLULAM™,BC FloorValue® ,VERSA-LAM®,VERSA-RIM PLUS®,VERSA-RIM®,VERSA-STRAND®,VERSA-STUD®are trademarks of Boise Cascade Wood Products L.L.C. Date Certificate Posted x Passive (No Fan) Active (With fan and monometer or other system monitoring device) Location (or future Location) of Fan: X R-10/R15 X X R-20 X R-20 X R-21 X R-49 X R-49 X R-30 X R-32 X Not applicable, all ducts located in conditioned space R-8 MECHANICAL SYSTEMS X Not required per mech. code Passive Powered Interlocked with exhaust device. Describe: Input in BTUS:60000 Capacity in Gallons:Other, describe: AFUE or HSPF%92% Cfm's " round duct OR " metal duct X Not required per mech. code Passive Low: Other, describe: X Low: Cfm's Capacity continuous ventilation rate in cfms: " round duct OR Total ventilation (intermittent + continuous) rate in cfms: " metal duct Cedar Crossings Plan ID 3035 East Foundation Wall Perimeter of Slab on Grade Rim Joist (Foundation) Community RADON SYSTEM Interior THERMAL ENVELOPE Either/OR, See Plans For Location In Attic Other Please Describe Here Below Entire Slab Total R-Value of all Types of InsulationType: Check All That Apply Non or Not ApplicableFiberglass, BlownFiberglass, Batts Insulation Location Foam, Closed CellFoam Open CellPer R401.3 Building Certificate. A building certificate shall be posted on or in the electrical distribution panel. New Construction Energy Code Compliance Certificate Name of Residential Contractor DRHorton MN License Number BC605657 Mailing Address of the Dwelling or Dwelling Unit 20554 Glade Avenue 155 Interior Bryant Domestic Water Heater Heating System NAT GAS Bryant 912SC36060S17 Average U-Factor (excludes skylights and one door) U: 0.31 Heating or Cooling Ducts Outside Conditioned Spaces Bonus room over garage Describe other insulated areas Fuel Type Solar Heat Gain Coefficient (SHGC): Windows & Doors Location of duct or system: Ceiling, vaulted Bay Windows or cantilevered areas Rim Joist (1st Floor+) Wall Mineral FiberboardRigid, Extruded PolystyreneRigid, Isocynurate Appliances Model R-value0.28 RU199i BA13NA024 Rinnai Make-up Air Select a Type Building Envelope air Tightness:Duct system air tightness: Ceiling, flat Manufacturer 78 50%=88 90%=158 NAT GAS R-410A Cooling System Rating or Size SEER or EER On Demand Output in Tons:2 Efficiency RESIDENTIAL LOAD CALC 13 Locations of Fans, describe: HEAT LOSS 41846 HEAT GAIN 16030 COOLING LOAD 21327 Location of duct or system: Select Type furnace room Heat Recover Ventilator (HRV) Capacity in cfms: Energy Recover Ventilator (ERV) Capacity in cfms: Describe any additional or combined heating or cooling systems if installed: (e.g. two furnaces or air source heat pump with gas back-up furnace Combustion Air Select a Type Balanced Ventilation Capcity in CFMS: High: High: Mechanical Ventilation System DRH 3035 HVAC Load Calculations for DR Horton Lakeville, MN Prepared By: Michael Hoium Sabre Plumbing & Heating 15535 Medina Road Plymouth, MN 55447 763-473-2267 Monday, July 22, 2019 Rhvac is an ACCA approved Manual J, D and S computer program. Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D. Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Sabre Plumbing & Heating DRH 3035 Plymouth, MN 55447 Page 2 Project Report General Project Information Project Title:DRH 3035 Designed By:Michael Hoium Project Date:Monday, July 22, 2019 Client Name:DR Horton Client City:Lakeville, MN Company Name:Sabre Plumbing & Heating Company Representative:Michael Hoium Company Address:15535 Medina Road Company City:Plymouth, MN 55447 Company Phone:763-473-2267 Company Fax:763-473-8565 Design Data Reference City:Minneapolis, Minnesota Building Orientation:Front door faces East Daily Temperature Range:Medium Latitude:44 Degrees Elevation:834 ft. Altitude Factor:0.970 Outdoor Outdoor Outdoor Indoor Indoor Grains Dry Bulb Wet Bulb Rel.Hum Rel.Hum Dry Bulb Difference Winter:-15 -15.33 n/a 30%72 33.90 Summer:88 73 50%50%75 35 Check Figures Total Building Supply CFM:711 CFM Per Square ft.:0.198 Square ft. of Room Area:3,592 Square ft. Per Ton:2,021 Volume (ft³):24,482 Building Loads Total Heating Required Including Ventilation Air:41,846 Btuh 41.846 MBH Total Sensible Gain:16,030 Btuh 75 % Total Latent Gain:5,297 Btuh 25 % Total Cooling Required Including Ventilation Air:21,327 Btuh 1.78 Tons (Based On Sensible + Latent) Notes Rhvac is an ACCA approved Manual J, D and S computer program. Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at your design conditions. Monday, July 22, 2019, 5:54 PM Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Sabre Plumbing & Heating DRH 3035 Plymouth, MN 55447 Page 3 Load Preview Report Scope Net Ton ft.² /Ton Area Sen Gain Lat Gain Net Gain Sen Loss Sys Htg CFM Sys Clg CFM Sys Act CFM Duct Size Building 1.78 2,021 3,592 16,030 5,297 21,327 41,846 483 711 711 System 1 1.78 2,021 3,592 16,030 5,297 21,327 41,846 483 711 711 10x14 Ventilation 860 3,596 4,457 5,757 Humidification 5,199 Zone 1 3,592 15,169 1,701 16,870 30,890 483 711 711 10x14 1-Basement 1,796 2,711 0 2,711 12,313 193 127 127 2--6 2-Main Floor 1,796 12,458 1,701 14,159 18,577 291 584 584 6--6 Monday, July 22, 2019, 5:54 PM Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Sabre Plumbing & Heating DRH 3035 Plymouth, MN 55447 Page 4 Total Building Summary Loads Component Description Area Quan Sen Loss Lat Gain Sen Gain Total Gain Low EE: Glazing-LowEE Builder Grade .31 U-value, .29 SHGC, Window and Patio Door, U-value 0.31, SHGC 0.29 227 6,127 0 2,919 2,919 11J: Door-Metal - Fiberglass Core, U-value 0.6 37.8 1,972 0 544 544 DRH- R15 8ft: Wall-Basement, Custom, DRH- 8" poured concrete wall, R-15 board insulation to footing, no interior finish, 8' floor depth, U-value 0.042 325.3 1,670 0 165 165 DRH- R10 4ft: Wall-Basement, Custom, DRH- 8" poured concrete wall, R-10 board insulation to footing, no interior finish, 4' floor depth, U-value 0.054 196 1,006 0 99 99 12F-0sw: Wall-Frame, R-21 insulation in 2 x 6 stud cavity, no board insulation, siding finish, wood studs, U-value 0.065 1545.2 8,738 0 1,335 1,335 15A-15sffc-8: Wall-Basement, concrete block wall, R-15 foam board to floor, no framing, no interior finish, filled core, 8' floor depth, U-value 0.034 325.3 962 0 0 0 15A-10sffc-8: Wall-Basement, concrete block wall, R-10 foam board to floor, no framing, no interior finish, filled core, 8' floor depth, U-value 0.042 392 1,432 0 0 0 RJ 20 Spray Foam: Wall-Frame, Custom, Rim Joist R-20 Closed Cell Spray Foam, U-value 0.05 269 1,170 0 330 330 R49 16B-49: Roof/Ceiling-Under Attic with Insulation on Attic Floor (also use for Knee Walls and Partition Ceilings), Custom, R-49 Blown Insulation, No Radiant Barrier, Vented Attic, Asphalt Shingles, U- value 0.023 1796 3,594 0 1,983 1,983 21A-20: Floor-Basement, Concrete slab, any thickness, 2 or more feet below grade, no insulation below floor, any floor cover, shortest side of floor slab is 20' wide, U-value 0.027 1796 4,219 0 0 0 Subtotals for structure:30,890 0 7,375 7,375 People:4 800 920 1,720 Equipment:901 4,116 5,017 Lighting:750 2,558 2,558 Ductwork:0 0 0 0 Infiltration: Winter CFM: 0, Summer CFM: 0 0 0 0 0 Ventilation: Winter CFM: 155, Summer CFM: 155 5,757 3,596 860 4,457 Humidification (Winter) 14.18 gal/day :5,199 0 0 0 AED Excursion:0 0 201 201 Total Building Load Totals:41,846 5,297 16,030 21,327 Check Figures Total Building Supply CFM:711 CFM Per Square ft.:0.198 Square ft. of Room Area:3,592 Square ft. Per Ton:2,021 Volume (ft³):24,482 Building Loads Total Heating Required Including Ventilation Air:41,846 Btuh 41.846 MBH Total Sensible Gain:16,030 Btuh 75 % Total Latent Gain:5,297 Btuh 25 % Total Cooling Required Including Ventilation Air:21,327 Btuh 1.78 Tons (Based On Sensible + Latent) Notes Rhvac is an ACCA approved Manual J, D and S computer program. Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at your design conditions. Monday, July 22, 2019, 5:54 PM Site address Contractor 1 Total/ continuous 60/40 70/40 80/40 90/45 100/50 110/55 120/60 130/65 140/70 150/75 Equation 11-1 Directions - Determine the total and continuous ventilation rate by either using Table R403.5.2 or equation 11-1. The table and equation are below Total required ventilation Continuous ventilation Section A Total ventilation – The mechanical ventilation system shall provide sufficient outdoor air to equal the total ventilation rate average, for each one‐hour period according to the above table or equation. For heat recovery ventilators (HRV) and energy recovery ventilators (ERV) the average hourly ventilation capacity must be determined in consideration of any reduction of exhaust or out outdoor air intake, or both, for defrost or other equipment cycling. Continuous ventilation - A minimum of 50 percent of the total ventilation rate, but not less than 40 cfm, shall be provided, on a continuous rate average for each one‐hour period. The portion of the mechanical ventilation system intended to be continuous may have automatic cycling controls providing the average flow rate for each hour is met. (0.02 x square feet of conditioned space) + [15 x (number of bedrooms + 1)] = Total ventilation rate (cfm) Date Completed By Ventilation Quantity (Determine quantity by using Table R403.5.2 or Equation 11‐1) Square feet (Conditioned area including Basement – finished or unfinished) Number of bedrooms Table R403.5.2 Total and Continuous Ventilation Rates (in cfm) Number of Bedrooms 2 3 4 5 6 Total/ continuous 1000‐1500 75/40 90/45 105/53 120/60 135/68 Conditioned space (in sq. ft.) Total/ continuous Total/ continuous Total/ continuous Total/ continuous 145/73 2001‐2500 95/48 110/55 125/63 140/70 155/78 1501‐2000 85/43 100/50 115/58 130/65 165/83 3001‐3500 115/58 130/65 145/73 160/80 175/88 2501‐3000 105/53 120/60 135/68 150/75 185/93 4001‐4500 135/68 150/75 165/83 180/90 195/98 3501‐4000 125/63 140/70 155/78 170/85 205/103 5001‐5500 155/78 170/85 185/93 200/100 215/108 4501‐5000 145/73 160/80 175/88 190/95 225/1135501‐6000 165/83 180/90 195/98 210/105 Continuous Ventilation Method (Choose either balanced or exhaust only) Low cfm:High cfm:Continuous fan rating in cfm (capacity must not exceed continuous ventilation rating by more than 100%) Ventilation Fan Schedule Description Location Intermittent Section C Directions - The ventilation fan schedule should describe what the fan is for, the location, cfm, and whether it is used for continuous or intermittent ventilation. The fan that is chose for continuous ventilation must be equal to or greater than the low cfm air rating and less than 100% greater than the continuous rate. (For instance, if the low cfm is 40 cfm, the continuous ventilation fan must not exceed 80 cfm.) Automatic controls may allow the use of a larger fan that is operated a percentage of each hour. Section D Directions - Describe the operation of the ventilation system. There should be adequate detail for plan reviewers and inspectors to verify design and installation compliance. Related trades also need adequate detail for placement of controls and proper operation of the building ventilation. If exhaust fans are used for building ventilation, describe the operation and location of any controls, indicators and legends. If an ERV or HRV is to be installed, describe how it will be installed. If it will be connected and interfaced with the air handling equipment, please describe such connections as detailed in the manufactures’ installation instructions. If the installation instructions require or recommend the equipment to be interlocked with the air handling equipment for proper operation, such interconnection shall be made and described. Section B Balanced, HRV (Heat Recovery Ventilator) or ERV (Energy Recovery Ventilator) – cfm of unit in low must not exceed continuous ventilation rating by more than 100%. Exhaust only Continuous fan rating in cfm Directions - Choose the method of ventilation, balanced or exhaust only. Balanced ventilation systems are typically HRV or ERV’s. Enter the low and high cfm amounts. Low cfm air flow must be equal to or greater than the required continuous ventilation rate and less than 100% greater than the continuous rate. (For instance, if the low cfm is 40 cfm, the ventilation fan must not exceed 80 cfm.) Automatic controls may allow the use of a larger fan that is operated a percentage of each hour. Ventilation Controls (Describe operation and control of the continuous and intermittent ventilation) One or multiple power vent or direct vent ap‐ pliances or no combus‐ tion appliances Column A One or multiple fan‐ assisted appliances and power vent or direct vent appliances Column B One atmospherically vent gas or oil appliance or one solid fuel appliance Column C Multiple atmospherical‐ ly vented gas or oil appliances or solid fuel appliances Column D 1. a) pressure factor (cfm/sf) 0.15 0.09 0.06 0.03 b) conditioned floor area (sf) (including unfinished basements) Estimated House Infiltration (cfm): [1a x 1b] 2. Exhaust Capacity a) continuous exhaust‐only ventilation system (cfm); (not applicable to ba‐ lanced ventilation systems such as HRV) b) clothes dryer (cfm)135 135 135 135 c) 80% of largest exhaust rating (cfm); Kitchen hood typically (not applicable if recirculating system or if powered makeup air is electrically interlocked and match to exhaust)d) 80% of next largest exhaust rating (cfm); bath fan typically (not applicable if recirculating system or if powered makeup air is electrically interlocked and matched to exhaust) Not Applicable Total Exhaust Capacity (cfm); [2a + 2b +2c + 2d] 3. Makeup Air Quantity (cfm) a) total exhaust capacity (from above) b) estimated house infiltration (from above) Makeup Air Quantity (cfm); [3a – 3b] (if value is negative, no makeup air is needed) 4. For makeup Air Opening Sizing, refer to Table 501.4.2 C. Use this column if there is one atmospherically vented (other than fan‐assisted) gas or oil appliance per venting system or one solid fuel appliance. D. Use this column if there are multiple atmospherically vented gas or oil appliances using a common vent or if there are atmospherically vented gas or oil appliances and solid fule appliances. Table 501.4.1 PROCEDURE TO DETERMINE MAKEUP AIR QUANITY FOR EXHAUST EQUIPMENT IN DWELLINGS (Additional combustion air will be required for combustion appliances, see KAIR method for calculations) Directions ‐ In order to determine the makeup air, Table 501.4.1 must be filled out (see below). For most new installations, column A will be appropriate, however, if atmospherically vented appliances or solid fuel appliances are installed, use the appropriate column. Please note, if the makeup air quantity is negative, no additional makeup air will be required for ventilation, if the value is positive refer to Table 501.4.2 and size the opening. Transfer the cfm, size of opening and type (round, rectangular, flex or rigid) to the last line of section D. A. Use this column if there are other than fan‐assisted or atmospherically vented gas or oil appliance or if there are no combustion appliances. (Power vent and direct vent appliances may be used.) B. Use this column if there is one fan‐assisted appliance per venting system. (Appliances other than atmospherically vented appliances may also be included.) One or multiple power vent, direct vent ap‐ pliances, or no combus‐ tion appliances Column A Multiple atmospherically vented gas or oil ap‐ pliances or solid fuel appliances Column D Duct di‐ ameter 1 – 36 1 – 9 3 37 – 66 10 – 17 4 67 – 109 18 – 28 5 110 ‐ 163 29 – 42 6 164 – 232 43 – 61 7 233 – 317 62 – 83 8 318 – 419 84 – 110 9 420 – 539 111 – 142 10 540 – 679 143 – 179 11 >679 >179 NA Notes: A. An equivalent length of 100 feet of round smooth metal duct is assumed. Subtract 40 feet for the exterior hood and ten feet for each 90‐ degree elbow to determine the remaining length of straight duct allowable. B. If flexible duct is used, increase the duct diameter by one inch. Flexible duct shall be stretched with minimal sags. Compressed duct shall not be accepted. C. Barometric dampers are prohibited in passive makeup air openings when any atmospherically vented appliance is installed. D. Powered makeup air shall be electrically interlocked with the largest exhaust system. Explanation ‐ If no atmospheric or power vented appliances are installed, check the appropriate box, not required. If a power vented or atmospherically vented appliance installed, use IFGC Appendix E, Worksheet E‐1 (see below). Please enter size and type. Combustion air vent supplies must communicate with the appliance or appliances that require the combustion air. Section F calculations follow on the next 2 pages. One or multiple fan‐ assisted appliances and power vent or direct vent appliances Column B One atmospherically vented gas or oil ap‐ pliance or one solid fuel appliance Column CPassive opening 1 – 22 1 – 15 Passive opening 23 – 41 16 – 28 Passive opening 42 – 66 29 – 46 Passive opening 67 – 100 47 – 69 Passive opening 101 – 143 70 – 99 231 – 290 Passive opening 144 – 195 100 – 135 Passive opening w/motorized damper 196 – 258 136 – 179 Passive (see IFGC Appendix E, Worksheet E‐1)Size and type Other, describe: Table 501.4.2 Makeup Air Opening Sizing Table for New and Existing Dwelling Units Powered makeup air >419 >290 Combustion air Not required per mechanical code (No atmospheric or power vented appliances) Passive opening w/motorized damper 259 – 332 180 – 230 Passive opening w/motorized damper 333 – 419 IFGC Appendix E, Worksheet E‐1 Residential Combustion Air Calculation Method (for Furnace, Boiler, and/or Water Heater in the Same Space) Step 1: Complete vented combustion appliance information. Furnace/Boiler: Draft Hood Fan Assisted Direct Vent Input: Btu/hr or Power Vent Water Heater: Draft Hood Fan Assisted Direct Vent Input: Btu/hr or Power Vent Step 2: Calculate the volume of the Combustion Appliance Space (CAS) containing combustion appliances. The CAS includes all spaces connected to one another by code compliant openings. CAS volume: ft3 L x W x H L W H Step 3: Determine Air Changes per Hour (ACH)1 Default ACH values have been incorporated into Table E‐1 for use with Method 4b (KAIR Method). If the year of construction or ACH is not known, use method 4a (Standard Method). Step 4: Determine Required Volume for Combustion Air. (DO NOT COUNT DIRECT VENT APPLIANCES) 4a. Standard Method Total Btu/hr input of all combustion appliances Input: Btu/hr Use Standard Method column in Table E‐1 to find Total Required TRV: ft3 Volume (TRV) If CAS Volume (from Step 2) i s gr ea t er th an TRV then no outdoor openings are needed. If CAS Volume (from Step 2) i s less than TRV then go to STEP 5. 4b. Known Air Infiltration Rate (KAIR) Method (DO NOT COUNT DIRECT VENT APPLIANCES) Total Btu/hr input of all fan-assisted and power vent appliances Input: Btu/hr Use Fan‐Assisted Appliances column in Table E‐1 to find RVFA: ft3 Required Volume Fan Assisted (RVFA) Total Btu/hr input of all Natural draft appliances Input: Btu/hr Use Natural draft Appliances column in Table E‐1 to find RVNFA: ft3 Required Volume Natural draft appliances (RVNDA) Total Required Volume (TRV) = RVFA + RVNDA TRV = + = TRV ft3 Step 5: Calculate the ratio of available interior volume to the total required volume. Ratio = CAS Volume (from Step 2) divided by TRV (from Step 4a or Step 4b) Ratio = / = Step 6: Calculate Reduction Factor (RF). RF = 1 mi nus Ratio RF = 1 ‐ = Step 7: Calculate single outdoor opening as if all combustion air is from outside. Total Btu/hr input of all Combustion Appliances in the same CAS Input: Btu/hr (EXCEPT DIRECT VENT) Combustion Air Opening Area (CAOA): Total Btu/hr d i vid ed by 3000 Btu/hr per in2 CAOA = / 3000 Btu/hr per in2 = in2 Step 8: Calculate Minimum CAOA. Minimum CAOA = CAOA multiplied by RF Minimum CAOA = x = in2 Step 9: Calculate Combustion Air Opening Diameter (CAOD) CAOD = 1.13 m ultiplied by the sq uare root of Minimum CAOA CAOD = 1.13 √ Minimum CAOA = in. diameter go up one inch in size if using flex duct 1 If desired, ACH can be determined using ASHRAE calculation or blower door test. Follow procedures in Section G304. Directions ‐ The Minnesota Fuel Gas Code method to calculate to size of a required combustion air opening, is called the Known Air Infiltration Rate Method. For new construction, 4b of step 4 is required to be filled out. 199,000 1994 to present Pre‐1994 1994 to present Pre‐1994 5,000 250 375 188 525 263 10,000 500 750 375 1,050 525 15,000 750 1,125 563 1,575 788 20,000 1,000 1,500 750 2,100 1,050 25,000 1,250 1,875 938 2,625 1,313 30,000 1,500 2,250 1,125 3,150 1,575 35,000 1,750 2,625 1,313 3,675 1,838 40,000 2,000 3,000 1,500 4,200 2,100 45,000 2,250 3,375 1,688 4,725 2,363 50,000 2,500 3,750 1,675 5,250 2,625 55,000 2,750 4,125 2,063 5,775 2,888 60,000 3,000 4,500 2,250 6,300 3,150 65,000 3,250 4,875 2,438 6,825 3,413 70,000 3,500 5,250 2,625 7,350 3,675 75,000 3,750 5,625 2,813 7,875 3,938 80,000 4,000 6,000 3,000 8,400 4,200 85,000 4,250 6,375 3,188 8,925 4,463 90,000 4,500 6,750 3,375 9,450 4,725 95,000 4,750 7,125 3,563 9,975 4,988 100,000 5,000 7,500 3,750 10,500 5,250 105,000 5,250 7,875 3,938 11,025 5,513 110,000 5,500 8,250 4,125 11,550 5,775 115,000 5,750 8.625 4,313 12,075 6,038 120,000 6,000 9,000 4,500 12,600 6,300 125,000 6,250 9,375 4,688 13,125 6,563 130,000 6,500 9,750 4,875 13,650 6,825 135,000 6,750 10,125 5,063 14,175 7,088 140,000 7,000 10,500 5,250 14,700 7,350 145,000 7,250 10,875 5,438 15,225 7,613 150,000 7,500 11,250 5,625 15,750 7,875 155,000 7,750 11,625 5,813 16,275 8,138 160,000 8,000 12,000 6,000 16,800 8,400 165,000 8,250 12,375 6,188 17,325 8,663 170,000 8,500 12,750 6,375 17,850 8,925 175,000 8,750 13,125 6,563 18,375 9,188 180,000 9,000 13,500 6,750 18,900 9,450 185,000 9,250 13,875 6,938 19,425 9,713 190,000 9,500 14,250 7,125 19,950 9,975 195,000 9,750 14,625 7,313 20,475 10,238 200,000 10,000 15,000 7,500 21,000 10,500 205,000 10,250 15,375 7,688 21,525 10,783 210,000 10,500 15,750 7,875 22,050 11,025 215,000 10,750 16,125 8,063 22,575 11,288 220,000 11,000 16,500 8,250 23,100 11,550 225,000 11,250 16,875 8,438 23,625 11,813 230,000 11,500 17,250 8,625 24,150 12,075 1. The 1994 date refers to dwellings constructed under the 1994 Minnesota Energy Code. The default KAIR used in this section of the table is 0.20 ACH. 2. This section of the table is to be used for dwellings constructed prior to 1994. The default KAIR used in this section of the table is 0.40 ACH. IFGC Appendix E, Table E‐1 Residential Combustion air (Required Interior Volume Based on Input Rating of Appliance) Input Rating (Btu/hr) Standard Method Known Air Infiltration Rate (KAIR) Method (cu ft) Fan Assisted or Power Vent Natural Draft NEW RESIDENTIAL CONSTRUCTION SWPPP VERIFICATION This form must be completed and submitted with all new residential permit applications. New residential building permits WILL NOT be issued without this completed form. Project Site Address: _____________________________________________________________________ Company Name: _________________________________________________________________________ Primary Contact: _________________________________________________________________________ Phone # (24 hr Contact): ______________________ Email: ______________________________________ Description of Land Disturbing Activity: _____________________________________________________ NPDES Construction Stormwater Permit # C000 ___ ___ ___ ___ ___ or # SUB00 ___ ___ ___ ___ ___ If you are not covered under a NPDES Construction Stormwater Permit administered by the MPCA, an erosion and sediment control plan MUST be submitted with the residential building permit application. “The permittee(s) shall ensure that the individuals are trained by local, state, federal agencies, professional organizations or other entities in erosion prevention, sediment control, permanent Stormwater management and the Minnesota NPDES/SDS Construction Stormwater Permit.” (NPDES Construction Stormwater Permit, MPCA) “The permittee(s) must ensure that a trained person (as identified in Part III.A.3.a) will routinely inspect the entire construction site at least once every seven (7) days during active construction and within 24 hours after a rainfall event greater than 0.5 inches in 24 hours.” (NPDES Construction Stormwater Permit, MPCA) Contact information of person CERTIFIED to provide weekly onsite erosion and sediment control inspections and corrective actions: Name of Person: ________________________________Company: _______________________________ Phone # (24 hr Contact): ______________________ Email: ______________________________________ Entity that Provided Training: ________________________ Certification Expiration Date: ____________ NOTE: Prior to any land-disturbing activity, all erosion and sediment controls must be installed on the project site and on individual lots. No land disturbing activity may begin until a residential building permit has been issued. I understand, the above information to be true and I will have read, understood, and accepted all terms and conditions of the National Pollutant Discharge Elimination System (NPDES) Permit (MN R 100001). The City of Lakeville may issue a STOP WORK ORDER; withhold building inspections; or, draw on securities/escrows to bring the site into compliance with the NPDES Construction Stormwater Permit (MN R 100001) or erosion and sediment control plan. Signature: ________________________________________________ Date:_________________________ Contact the City of Lakeville with questions at erosion@lakevillemn.gov or 952-985-4500 Cole Feriancek X10/13/20 DJM