HomeMy WebLinkAbout18095 Jaguar Path Survey(1084.0)(1096.5)
(1091.5)
(1092.34)(1082.2)OS 54.99HUB=1077.25PORCH
PROPOSED
HOUSE DECKGAR.30.3317.50
17.65
R:
1
0
9
5
.
5
3
FD IP FD IP FD IPOS 17.99HUB=1089.19OS 17.65HUB=1088.51OS 13.65HUB=1079.7414''1088.018''1091.620''1095.7101010
10
1010101010105
5
5
5
JAG
U
A
R
P
A
T
H S48°31'48"E 159.28S89°33'02"W 323.67S00°26'58"E 98.43 S77°05'00"E123.04N04°39'06"E
56.37
N00°54'22"W37.30
N45°55'51"E41.94N17°44'33"E41.91N35°59'06"E62.78N00°26'59"W20.58
26.00 22.00 16.00 6.50 2.00 23.50
14.00 18.00 40.00 41.50 8.00 7.00 6.00 21.50 7.00 24.00 7.00
15.001069.6
1079.7
1080.51081.01079.7
1070.11071.7
1078.41074.81077.01
0
7
2
.
6
1
0
7
9
.
7
10
9
6
.
4
10
9
6
.
4
1097.3
1097.6
1096.5 1095.91088.71081.51081.41080.51090.71088.51089.8(1082.2)(1092.0)(1088.5)(1079.7)(1077.3)(1089.2)(1095.9)
FBWO
FBWO(1082.2)4.1%10.0%1093.0
PATIODRAINAGE &UTILITY EASEMENTEX. RETAINING WALLFD IPFD IPFD IPFD IPFD IPFD IPFD IPFD IPDENOTES EXISTING CATCH BASINDENOTES EXISTING HYDRANTDENOTES EXISTING SANITARY MANHOLEDENOTES EXISTING STORM MANHOLEDENOTES EXISTING UTILITY BOXDENOTES EXISTING SERVICE OR CLEANOUTDENOTES IRON MONUMENT FOUNDDENOTES IRON MONUMENT SETDENOTES EXISTING POWER POLEDENOTES EXISTING LIGHT POLEDENOTES EXISTING CONSERVATION POSTOR WET LAND BUFFER POSTDENOTES EXISTING TREE8" TREE000.0DENOTES WOOD HUBDENOTES NAILDENOTES EXISTING RETAINING WALLDENOTES PROPOSED RETAINING WALLDENOTES EXISTING ELEVATIONDENOTES PROPOSED ELEVATIONDENOTES AS BUILT ELEVATION(000.0)000.0DENOTES EXISTING TREELINEDENOTES DIRECTION OF SURFACE DRAINAGEDENOTES EXISTING FENCELEGENDDENOTES EXISTING F.E.S.LOT AREA : 42,514 SQ. FT.HOUSE AREA : 2,010 SQ. FT.PORCH AREA : 168 SQ. FT.DECK AREA : 105 SQ. FT.COVERAGE AREA : 2,283 SQ. FT. (5.4%)CERTIFICATE OF SURVEYLegal Description:= FINISHED GARAGE FLOOR ELEVATION= BASEMENT FLOOR ELEVATION= TOP OF FOUNDATION ELEVATION(1092.34)(1092.34)(1082.67)1. No specific soils investigation has been performed on this lotby the surveyor. The suitability of the soils to support the specifichouse is not the responsibility of the surveyor.2.No title information was provided for this survey. This surveydoes not purport to show all easements of record.3. See architectural plans for final building dimensions.BENCHMARK:TNH AT L1 - B7, RAVEN LAKE SECOND ADDITION.ELEVATION = 1100.91AREAS:NOTES: 1. ROCK CONSTRUCTION ENTRANCE AT DRIVEWAY. 2. EROSION CONTROL AT GRADING LIMITS.Zoning = RS-2FY - 30'SY - 15' Interior, 30' CornerRY - 30'SY Buffer - 40'RY Buffer - 50'The curb box, drain tile cleanout, and catchbasin(if applicable) must be inspected andaccepted before As-Built escrow monies willbe released. All structures must be flushwith the sod. This will be scheduled with thelandscape inspection.*Maintain 6" between bottom of siding and sod.*No structures in easements.ENGINEERING REVIEWEDDate:__________________10/30/2020corlowskyEROSION CONTROLMUST BE INSTALLEDBEFORE EXCAVATION