Loading...
HomeMy WebLinkAboutPlan Set13000#17000#LAY01LAY02T01ET01T02T02T02T02G01T02ET03T03T03T03T03T03T03M03EM03M03M03M03M03M03M03M03M03M03M03M03M03M03M03M03EM02EM02M02M02M02M02T03T05AT05BT05CT05DT03T03T03T02EV01V02V03V04V05PB01PB02PB02PB02PB02PB02PB0219401 Tamarack Street NWOak Grove, MN 55011PHONE: (612) 656-1642DIMENSIONING NOTES:ALL DIMENSIONS ARE OR HAVE BEENADJUSTED TO SHEATHING xxxBrandl AndersonxxxJOB #:SCALE:DRAWNBY:DATE:10/14/2020Andrew1/4" = 1'-0"Glacier Creek TownhomesEnd Unitxxxxxx, MNADDRESS:PROJECT:BUILDER:THESE PLANS ARE DESIGNED TO ASSIST IN THELOCATION AND ERECTION OF BUILDERS FIRSTSOURCETRUSSES ONLY. THEY ARE IN NO WAY TO BEREGARDED AS COMPLETE CONSTRUCTION DRAWINGS.THE BUILDER IS TOTALLY RESPONSIBLE FOR ERECTIONAND COMPLETION OF THE BUILDING, USINGSATISFACTORY CONSTRUCTION METHODS ANDTECHNIQUES AND FOR COMPLIANCE WITH ALL LOCAL,STATE AND FEDERAL CODES, ORDINANCES, ANDSTATUTES IN THAT REGARD.HANGER GENERAL NOTICE:REVISION DATESET CREW SHALL BE SOLELY RESPONSIBLE FOR CORRECTINSTALLATION OF ALL HANGERS. THIS SHALL INCLUDE, BUTNOT BE LIMITED TO, CORRECT NAIL SIZE, CORRECT NAILDIAMETER, CORRECT HANGER LOCATION, AND CORRECTHANGER SIZE AS NOTED ON THIS TRUSS LAYOUT. ALL NAILHOLES ARE TO BE FILLED PER HANGER SPECIFICATION.ANY DISCREPANCY BETWEEN HANGERS NOTED ON PLANAND HANGERS DELIVERED TO SITE SHALL BE REPORTEDPRIOR TO THE HANGERS INSTALLATION.GENERAL NOTICE:PAINTED END INDICATES THE TRIANGLE ENDSHOWN ON THE LAYOUTPAINTED END INDICATES THE TRIANGLE ENDSHOWN ON THE LAYOUTFOR QUESTIONS REGARDINGTHIS LAYOUTPLEASE CONTACT:Andrew @ 612-656-1643 BM1BM2BM4roof girderF01F01F01F01F01F01F02F02F02F02F02F02F02F02F02F02F02F02F02F02EF04FG01F05F03EF06F06F07F08F01EF04E19401 Tamarack Street NWOak Grove, MN 55011PHONE: (612) 656-1642DIMENSIONING NOTES:ALL DIMENSIONS ARE OR HAVE BEENADJUSTED TO SHEATHINGxxxBrandl AndersonxxxJOB #:SCALE:DRAWNBY:DATE:10/14/2020Andrew1/4" = 1'-0"Glacier Creek TownhomesEnd Unitxxxxxx MNADDRESS:PROJECT:BUILDER:THESE PLANS ARE DESIGNED TO ASSIST IN THELOCATION AND ERECTION OF BUILDERS FIRSTSOURCETRUSSES ONLY. THEY ARE IN NO WAY TO BEREGARDED AS COMPLETE CONSTRUCTION DRAWINGS.THE BUILDER IS TOTALLY RESPONSIBLE FOR ERECTIONAND COMPLETION OF THE BUILDING, USINGSATISFACTORY CONSTRUCTION METHODS ANDTECHNIQUES AND FOR COMPLIANCE WITH ALL LOCAL,STATE AND FEDERAL CODES, ORDINANCES, ANDSTATUTES IN THAT REGARD.HANGER GENERAL NOTICE:REVISION DATESET CREW SHALL BE SOLELY RESPONSIBLE FOR CORRECTINSTALLATION OF ALL HANGERS. THIS SHALL INCLUDE, BUTNOT BE LIMITED TO, CORRECT NAIL SIZE, CORRECT NAILDIAMETER, CORRECT HANGER LOCATION, AND CORRECTHANGER SIZE AS NOTED ON THIS TRUSS LAYOUT. ALL NAILHOLES ARE TO BE FILLED PER HANGER SPECIFICATION.ANY DISCREPANCY BETWEEN HANGERS NOTED ON PLANAND HANGERS DELIVERED TO SITE SHALL BE REPORTEDPRIOR TO THE HANGERS INSTALLATION.GENERAL NOTICE:PAINTED END INDICATES THE TRIANGLE ENDSHOWN ON THE LAYOUTPAINTED END INDICATES THE TRIANGLE ENDSHOWN ON THE LAYOUTFLOOR TRUSSES SUPPORTING TILE FLOORINGMaximum truss spacing shall be 16" o.c. per ANSI A108/ANSI A118/136.Perpendicular blocking installed at 16" o.c. maximum shallbe permitted inlieu of the 16" o.c. truss spacing.FOR QUESTIONS REGARDINGTHIS LAYOUTPLEASE CONTACT:Andrew @ 612-656-1643 LAY01BM1BM2BM3BM4T02GT04ET02ET03T03T03T03T02T02T02T05T05T05T04T06T01GT03ET07T07T01ET01T01M04M04M04M04M04M04M03M03M04EM03EM02M02M02M02M02EM01EM01M01M01M01M01M01M01M01M01M01M01M01M01M01M01M01EJ02J02J02J01J03J02V01V02V03V04V05V06V07V08UndesignedUndesignedUndesignedUndesignedUndesignedUndesignedUndesignedUndesignedUndesignedUndesignedUndesignedUndesignedUndesignedUndesignedUndesignedUndesignedUndesignedUndesigned19401 Tamarack Street NWOak Grove, MN 55011PHONE: (612) 656-1642DIMENSIONING NOTES:ALL DIMENSIONS ARE OR HAVE BEENADJUSTED TO SHEATHING xxxBrandl AndersonxxxJOB #:SCALE:DRAWNBY:DATE:7/20/2020Andrew1/4" = 1'-0"Glacier Creek TownhomesMiddle Unitsxxxxxx, MNADDRESS:PROJECT:BUILDER:THESE PLANS ARE DESIGNED TO ASSIST IN THELOCATION AND ERECTION OF BUILDERS FIRSTSOURCETRUSSES ONLY. THEY ARE IN NO WAY TO BEREGARDED AS COMPLETE CONSTRUCTION DRAWINGS.THE BUILDER IS TOTALLY RESPONSIBLE FOR ERECTIONAND COMPLETION OF THE BUILDING, USINGSATISFACTORY CONSTRUCTION METHODS ANDTECHNIQUES AND FOR COMPLIANCE WITH ALL LOCAL,STATE AND FEDERAL CODES, ORDINANCES, ANDSTATUTES IN THAT REGARD.HANGER GENERAL NOTICE:REVISION DATESET CREW SHALL BE SOLELY RESPONSIBLE FOR CORRECTINSTALLATION OF ALL HANGERS. THIS SHALL INCLUDE, BUTNOT BE LIMITED TO, CORRECT NAIL SIZE, CORRECT NAILDIAMETER, CORRECT HANGER LOCATION, AND CORRECTHANGER SIZE AS NOTED ON THIS TRUSS LAYOUT. ALL NAILHOLES ARE TO BE FILLED PER HANGER SPECIFICATION.ANY DISCREPANCY BETWEEN HANGERS NOTED ON PLANAND HANGERS DELIVERED TO SITE SHALL BE REPORTEDPRIOR TO THE HANGERS INSTALLATION.GENERAL NOTICE:PAINTED END INDICATES THE TRIANGLE ENDSHOWN ON THE LAYOUTPAINTED END INDICATES THE TRIANGLE ENDSHOWN ON THE LAYOUTFOR QUESTIONS REGARDINGTHIS LAYOUTPLEASE CONTACT:Andrew @ 612-656-1643 BM1BM2BM3BM4BM5BM6BM7BM8BM9BM10BM11F01F01F01F02F02F02F03F03F03F03F03F03F03F04F04F04F01EF05F05F05F02EF03EF04EF06F07F06F07F06F08F09F0919401 Tamarack Street NWOak Grove, MN 55011PHONE: (612) 656-1642DIMENSIONING NOTES:ALL DIMENSIONS ARE OR HAVE BEENADJUSTED TO SHEATHINGxxxBrandl AndersonxxxJOB #:SCALE:DRAWNBY:DATE:7/20/2020Andrew1/4" = 1'-0"Glacier Creek TownhomesMiddle Unitxxxxxx MNADDRESS:PROJECT:BUILDER:THESE PLANS ARE DESIGNED TO ASSIST IN THELOCATION AND ERECTION OF BUILDERS FIRSTSOURCETRUSSES ONLY. THEY ARE IN NO WAY TO BEREGARDED AS COMPLETE CONSTRUCTION DRAWINGS.THE BUILDER IS TOTALLY RESPONSIBLE FOR ERECTIONAND COMPLETION OF THE BUILDING, USINGSATISFACTORY CONSTRUCTION METHODS ANDTECHNIQUES AND FOR COMPLIANCE WITH ALL LOCAL,STATE AND FEDERAL CODES, ORDINANCES, ANDSTATUTES IN THAT REGARD.HANGER GENERAL NOTICE:REVISION DATESET CREW SHALL BE SOLELY RESPONSIBLE FOR CORRECTINSTALLATION OF ALL HANGERS. THIS SHALL INCLUDE, BUTNOT BE LIMITED TO, CORRECT NAIL SIZE, CORRECT NAILDIAMETER, CORRECT HANGER LOCATION, AND CORRECTHANGER SIZE AS NOTED ON THIS TRUSS LAYOUT. ALL NAILHOLES ARE TO BE FILLED PER HANGER SPECIFICATION.ANY DISCREPANCY BETWEEN HANGERS NOTED ON PLANAND HANGERS DELIVERED TO SITE SHALL BE REPORTEDPRIOR TO THE HANGERS INSTALLATION.GENERAL NOTICE:PAINTED END INDICATES THE TRIANGLE ENDSHOWN ON THE LAYOUTPAINTED END INDICATES THE TRIANGLE ENDSHOWN ON THE LAYOUTFLOOR TRUSSES SUPPORTING TILE FLOORINGMaximum truss spacing shall be 16" o.c. per ANSI A108/ANSI A118/136.Perpendicular blocking installed at 16" o.c. maximum shallbe permitted inlieu of the 16" o.c. truss spacing.FOR QUESTIONS REGARDINGTHIS LAYOUTPLEASE CONTACT:Andrew @ 612-656-1643