HomeMy WebLinkAboutLA186548 - 8194 198th St W Permit PackRESIDENTIAL BUILDING
PERMIT APPLICATION
CITY OF LAKEVILLE
BUILDING INSPECTIONS DEPARTMENT
20195 HOLYOKE AVENUE
LAKEVILLE, MN 55044
952-985-4440
Office Use Only
__________________
Permit Number
___________________
Received By
___________________
Date Received
___________________
Fee Total
SITE ADDRESS:
MAILING ADDRESS: CITY: STATE: ZIP:
JOB DESCRIPTION:__________________________________ MASTER PLAN: (Number or Address)____________________
LIST OTHER STRUCTURES ON PROPERTY:_______________________________________________________________
ESTIMATED VALUATION: PROPOSED START DATE: END DATE:
(New Residential Only): LEGAL DESCRIPTION: LOT: _____ BLOCK: _____ SUBDIVISION:
APPLICANT IS: RESIDENT OWNER CONTRACTOR EMAIL
NEW MODEL HOME: YES NO (IF YES – ADMINISTRATIVE PERMIT REQUIRED)
PLEASE FILL OUT THE FOLLOWING COMPLETELY (All Contractor information must be as listed on State License)
RESIDENT OWNER
NAME:_______________________________________________________________________________
HOME PHONE #:_____________________________ CELL PHONE:___________________________
GENERAL CONTRACTOR
Homeowner
Contractor
CONTRACTOR:_______________________________________________________________________
LICENSE #:BC______________ LEAD CERTIFICATE#_______________ (PRE 1978 STRUCTURE)
OFFICE PHONE #:_____________________________ CELL PHONE:___________________________
ADDRESS:____________________________ CITY:________________ ST:______ ZIP:____________
PLUMBING WORK
Homeowner
Contractor
CONTRACTOR:__________________________________________LICENSE #: PM______________
OFFICE PHONE #:_____________________________ CELL PHONE:___________________________
ADDRESS:____________________________ CITY:________________ ST:______ ZIP:____________
MECHANICAL WORK
Homeowner
Contractor
CONTRACTOR:________________________________________ _______________________________
OFFICE PHONE #:_____________________________ CELL PHONE:___________________________
ADDRESS:____________________________ CITY:________________ ST:______ ZIP:____________
BOND #:_______________________________________ EXPIRATION DATE____________________
SEWER/WATER CONTRACTOR
New Construction Only
NAME:________________________________________________ ______________________________
HOME PHONE _____________________________ CELL PHONE:______________________________
BOND #:_______________________________________ EXPIRATION DATE____________________
INTEREST EARNINGS ON THE ESCROW ACCOUNTS, IF ANY, ARE RETAINED BY THE CITY TO OFFSET THE
ADMINISTRATIVE COSTS ASSOCIATED WITH PROCESSING THE ESCROW APPLICATION AND REFUND. I HEREBY
APPLY FOR A BUILDING PERMIT AND I ACKNOWLEDGE THAT THE INFORMATION ABOVE IS COMPLETE AND
ACCURATE; THAT THE WORK WILL BE IN CONFORMANCE WITH THE ORDINANCES AND CODES OF THE CITY AND
WITH THE STATE BUILDING CODE, THAT I UNDERSTAND THIS IS NOT A PERMIT AND WORK IS NOT TO START
WITHOUT A PERMIT AND THAT THE WORK WILL BE IN ACCORDANCE WITH THE APPROVED PLAN.
NAME OF APPLICANT (Please Print)DATE
APPLICANT’S SIGNATURE:
www.lakevillemn.gov
RESIDENTIAL BUILDING PERMIT APPLICATION
PAGE 2
OFFICE USE ONLY
BUILDING PERMIT TYPE REQUIRED INSPECTIONS
SINGLE FAMILY DWELLING BUILDING
DUPLEX AS BUILT
TOWNHOUSE UNITS BUILDING FINAL
DETACHED TOWN HOUSE UNIT DECK FOOTING
CONDO FIREPLACE
ACESSORY BUILDING FOOTING
REROOF FOUNDATION
RESIDE FRAMING
PORCH FRAMING
GARAGES
INSULATION
RES ADDN/REPAIR/RMDL
DECK
PORCH
GARAGES LATH
LOWER LEVEL FINISH LOWER LEVEL FINAL
ADDITION OTHER
FOUNDATION ONLY PORCH FOOTING
MISCELLANEOUS POURED WALL
DEMO SEPTIC TANK REMOVAL
MOVED SITE
MECHANICAL
CITY BUILDING VALUATION: $AIR TEST
FINAL
BUILDING PERMIT FEES ROUGH-IN
$PERMIT FEE PLUMBING
$PLAN CHECK FINAL
$SURCHARGE ROUGH-IN
$METRO SAC METER SIZE
$CITY WATER HOOKUP UNIT PRESSURE REDUCING VALVE
$CITY SEWER HOOKUP UNIT SEWER/WATER
$LANDSCAPE ESCROW SEWER/WATER
$TREE ESCROW FINAL
$MISC ESCROW STREET DRAINTILE
$PLUMBING BUILDING INFORMATION
$MECHANICAL TYPE OF CONSTRUCTION
$SEWER WATER ZONING
$OTHER CODE EDITION
$TOTAL FIRE SUPPRESSION SYSTEM
OCCUPANCY GROUP
APPROVED BY:
BUILDING INSPECTOR: Date:
PLUMBING/MECHANICAL
INSPECTOR: Date:
COMMENTS:
20195 Holyoke Avenue, Lakeville, MN 55044
952-985-4400 952-985-4499 fax
www.lakevillemn.gov
Sewer & Water Tie Card
Address:________________________________________
Contractor:______________________________________
Permit Number:__________________________________
Final Date:________________
Street Drain-Tile:______
Size of Water Service: 1”
Comments: AIRTEST SANITARY OVER 20’/2 FITTINGS
THIS CARD MUST BE COMPLETED AND ON-SITE AT TIME
OF SEWER & WATER INSPECTION
Concept Approval
ONLY
Subject to Field Inspection
Inspector Date
2020
MN Bldg
Code
11/30/2020dmathews
(3)2x10 (3)9-1/2 LVL (3)9-1/2 LVL
(2)11-7/8 LVL
UFER Ground
-Provide 20' Rebar in footing and stub
up near electrical service panel.
(2)9-1/2" LSL (2)9-1/2 LVL (2)11-7/8 LSL
Temper if within
60" of tub floor
Smoke
CO
Smoke
CO
(2)2x8(3)2x8(2)2x8
(2)9-1/2" LSL
(2)9-1/2" LSL
(2)11-7/8 LSL
(2)16" LVL
-Min. 15" clearance to any
obstruction from center of
W.C., 24" in front(typ).
CS-PF
CS-PF CS-PF
Verify hip girder
locations and
provide blocking
to foundation
below for point
loads.
Address: 8194 198th Street
Braced Wall Line Notes Reference table R602.10.3(1) (pg220)LocationWindStorySpacingMethodMin. Lngth Ft.*Wind Exp. BRoof Ridge*Wall Hgt FctrLine CountLine Count FctrInterior GypsumTotal Req'd Ft.Total DesignedBWL #1 <90 2 36 CS-WSP 10.80 1.00 1.11 0.90 2 1.00 1.00 10.79 20.00 pass
BWL #2 <16'<90 2 60 CS-WSP 17.00 1.00 1.11 0.90 2 1.00 1.00 4.00 14.00 pass
BWL #3 <16'<90 2 60 CS-WSP 17.00 1.00 1.11 0.90 2 1.00 1.00 4.00 14.00 pass
BWL #4 <90 1 31.5 CS-PF**5.15 1.00 0.98 1.00 3 1.30 1.00 6.56 7.63 pass
BWL #5 <16'<90 1 31.5 CS-WSP 5.15 1.00 0.98 1.00 3 1.30 1.00 4.00 9.50 pass
BWL #6 <90 1 41 CS-WSP 6.15 1.00 0.98 1.00 3 1.30 1.00 7.84 14.00 pass
BWL #7 <90 1 41 CS-WSP 6.15 1.00 0.98 1.00 3 1.30 1.00 7.84 12.00 pass
BWL #8 <90 1 36 CS-WSP 5.60 1.00 1.22 0.95 3 1.30 1.00 8.44 12.00 pass
BWL #9 <90 1 36 CS-WSP 5.60 1.00 1.22 0.95 3 1.30 1.00 8.44 16.00 pass
BWL #10 <90 1 60 CS-WSP 9.00 1.00 1.22 0.95 3 1.30 1.00 13.56 15.00 pass
BWL #11 <90 1 60 CS-WSP 9.00 1.00 1.22 0.95 3 1.30 1.00 13.56 16.50 pass
Braced Wall Panel Notes ft inches
(per table R602.10.5, pg229)main roof 13 8.000 13.6667
Method Loc.AdjOpng Wall Ht Min. Req'd garage roof 9 8.000 9.66667
CS-WSP typ <80"9'30">=32"
CS-PF**A NA <11'22"26 1/2
* Braced wall lengths and ridge height factors use linear interpolation
** Portal Frame follow R602.10.6.4 (pg233) over masonry foundation
*** Braced wall length reduced by factor 0.8 for additional 800lb strap
SCOPE OF WORK:
INDEX:
S1 - Scope, Index, and Certification
S2 - General Notes
S3 - Step Footing Detail
S4 - Frost Wall Detail
S5 - Lookout Wall Detail
S6 - Full Height Wall Detail
MATERIALS:
Reinforcing Steel: Grade 40 (40 ksi) for #4 and smaller bars
Grade 60 (60 ksi) for #5 bars and larger
Rebar Substitution Notes:
1.Two #4's bundled may be used to substitute (1)#6 and vice versa provided they are of the same grade steel.
2.For vertical bars on S6, #5's may be used in lieu of #6's at two-thirds of the noted spacing.
Concrete: Mix design is to be prepared by the concrete supplier to meet the project's requirements
Minimum 28 day compressive strength of 3000 psi for walls
Minimum 28 day compressive strength of 5000 psi for footings
Backfill Soil:Sand - 30 psf/ft effective lateral pressure
Sandy Clay (SC) - 45 psf/ft effective lateral pressure
Clay - 60 psf/ft effective lateral pressure
SITE ADDRESS:
Street:
City:
State:MN Zip:Craig Oswell, PE (MN #42341)
Oswell Engineering and Consulting, L.L.C.
Project Name:2020 Standardized Concrete Foundation Drawings
Description:Scope of Work, Index, and Certification
Project #19.100
Client Name:Kopp Concrete Inc.
Client Address:16455 122th Street, Becker, MN 55308
34
2020 Standardized Concrete Foundation Drawings
1/1/2020
The drawings are to only be used by the contractor noted below or his authorized sub-contractors/clients.
These drawings are to be provided to the building inspection department as part of the permit package.
These drawings apply to the construction of cast-in-place concrete foundation walls for typical residential
cases. These drawings are not to scale and all conditions are to be verified by the contractor. Means and
methods of construction for shoring, water-proofing, insulation, flashing, control and construction joints,
and all other non-structural requirements are to be by others in accordance with the Code and standard
industry practice. These drawings are valid until the end of 2020.
1901 E Hennepin Ave, #201
Footings may be 3000 psi if an approved admixture is used to achieve a water and vapor
resistance equivalent to 5000 psi
I hereby certify that this plan, specification, or
report was prepared by me or under my direct
supervision and that I am a duly licensed
professional engineer under the laws of the state
of Minnesota.
Page S1 of S6
Minneapolis, MN 55413
Phone: 612-720-4639
Fax: 612-886-2966
www.oswellec.com
GENERAL NOTES:
1.Wall thicknesses noted are nominal unless specifically stated otherwise.
2.Maximum wall to footing centerline offset is 2". A minimum of 2" of footing is to extend on each side of the wall.
3.Bar laps when required are to be at least 40 bar diameters for grade 40 and 60 bar diameters for grade 60.
4.Bend horizontal bars or provide matching hooks around all wall corners and intersections.
5.Horizontal bars may be placed anywhere within the wall thickness provided 2" minimum cover is provided.
6.Allowable bar placement tolerance is 1/2". Tying is not required if tolerances are met and maintained.
7.
8.
9.Anchor bolts 1/2" or larger in diameter do not require corrosion protection per IRC section R317.3.1 exception 1.
10.Anchor bolts may be substituted with 1/2" diameter threaded rod epoxy grouted at same spacing with 7" embed.
11.The presence of form oil on the reinforcing is acceptable for the conditions contained in these drawings.
12.Slope grade 6" minimum downward away from foundations within first 10 feet or provide Code adequate swale.
13.
14.
COLD WEATHER GUIDELINES:
1.
2.Concrete is to be delivered to the site in a timely manner.
3.Placement of concrete earlier in the day to take advantage of latent heat of sunlight is advised.
4.Do not add additional water. Using water-reducing admixtures is recommended when required.
5.Forms are to be free of snow and ice. Do not place concrete in contact with frozen ground, snow, or ice.
6.Preheating of rebar is not required, however it is to be free of frost, snow, and ice.
7.
Oswell Engineering and Consulting, L.L.C.
Project Name:2020 Standardized Concrete Foundation Drawings
Description:General Notes
Project #19.100
Client Name:Kopp Concrete Inc.
Client Address:16455 122th Street, Becker, MN 55308
34
Dowels may be drilled and installed after footing pour unless otherwise noted. Vertical bars may be embedded
into footing in place of dowels at the same embedment. Vertical bars and dowels do not need to align. Dowels
may be bent down for safety and covering then bent back before wall placement.
The following information is general guidelines for the placement of concrete in cold weather conditions. It is the
contractor's responsibility to ensure proper means and methods are followed and that the final in place product is
adequate.
1901 E Hennepin Ave, #201
Minneapolis, MN 55413
Use of form blankets or other approved protection is highly recommended for the top of the wall at temperatures
below 10 degrees F and for the whole wall when below zero degrees F.
The contractor is to work with the concrete supplier to obtain a mix design which accounts for the conditions
expected. Use of extra cement, early-strength concrete, and accelerators are recommended at temperatures
below 20 degrees F.
Sill plate sections require at least two anchors with one within 4" to 12" of each end and at all corners and
intersections. Walls less than 24" in length require only one anchor. Sill plates may overhang the face of the wall
provided the overhang is not loaded vertically and all anchor bolt/connection tolerances are met.
Do not backfill until the concrete has reached at least 70 percent of the 28 day concrete strength. Use of
adequate shoring is required when the final floor and slab systems are not in place and fully anchored.
Maximum inside window well dimension is 72". Well walls are to be at least 8" thick placed monolithically with
house walls with horizontal bars extended into them and around corners. Provide two additional vertical bars and
one additional anchor bolt each side of opening. Opening header by others.
1/1/2020
Fax: 612-886-2966
www.oswellec.com
Page S2 of S6
Phone: 612-720-4639
HIGH FOOTING
LOW FOOTING
FOOTING STEP DETAIL
Oswell Engineering and Consulting, L.L.C.
Project Name:2020 Standardized Concrete Foundation Drawings
Description:Step Footing Detail (NOT TO SCALE)
Project #19.100
Client Name:Kopp Concrete Inc.
Client Address:16455 122th Street, Becker, MN 55308
34
Adjacent steps are to be
placed no closer to either side
of the beam section than twice
the height of the largest step6'-0" maximum step
Optional control joint each end
of beam section by others
24" min(2) bundled #4 horizontal bars
top & bottom w/ 3" min
clearance extended at least
24" minimum beyond each end
of beam section (bar length =
step height + 4')
High footing should be placed
at 1-to-1 (45 degree) line, if
high footing is closer to step
than this line, place beam
section rebar as if it was at
this line as shown
1/1/2020
(beam section)
www.oswellec.com
Page S3 of S6
Phone: 612-720-4639
Fax: 612-886-2966
1901 E Hennepin Ave, #201
Minneapolis, MN 55413
Maximum applied
actual load = 4000 plf
uniform or 12,000
pound concentrated 6" minimum thick cast-in-place
concrete foundation wall
Wall framing by others
WALKOUT/ SLAB-ON-GRADE FROST WALL DETAIL
Note: Maximum unbalanced fill height is 36" for 8" thick wall & 48" for 10" wall
Oswell Engineering and Consulting, L.L.C.
Project Name:2020 Standardized Concrete Foundation Drawings
Description:Frost Wall Detail (NOT TO SCALE)
Project #19.100
Client Name:Kopp Concrete Inc.
Client Address:16455 122th Street, Becker, MN 55308
34
Grade to be at least 6" below top
of wall
Sill plate by others w/ 1/2"
diameter anchor bolts w/ 7"
minimum embed & standard
washers @ 72" o.c. max or
equivalent metal strap anchors
(Anchor bolt clearance between
edge of both wall and sill plate is
to be 2")
6" minimum thick cast-in-place
concrete wall
Page S4 of S6
(1)#4 continuous horizontal bar
w/in 18" of top of wall
1901 E Hennepin Ave, #201
Minneapolis, MN 55413
Phone: 612-720-4639
Fax: 612-886-2966
www.oswellec.com
#4 x 2'-0" long dowels @ 72" o.c.
max w/ 5" minimum embed
Unreinforced concrete strip
footing per Code by others,
provide frost protection per Code
as required
1/1/2020
Optional slab ledge, maximum
stem height is 12" w/ width to
match sill plate
Wall framing by others
6" wall spacing:
8"+ wall spacing:
LOOKOUT WALL DETAIL
Oswell Engineering and Consulting, L.L.C.
Project Name:2020 Standardized Concrete Foundation Drawings
Description:Lookout Wall Detail (NOT TO SCALE)
Project #19.100
Client Name:Kopp Concrete Inc.
Client Address:16455 122th Street, Becker, MN 55308
34
Grade to be at least 6" below top
of wall
Sill plate by others w/ 1/2"
diameter anchor bolts w/ 7"
minimum embed & standard
washers @ 72" o.c. max or
equivalent metal strap anchors
(Anchor bolt clearance between
edge of both wall and sill plate is
to be 2")
Page S5 of S6
(1)#4 continuous horizontal bar
w/in 18" of top of wall
1901 E Hennepin Ave, #201
Minneapolis, MN 55413
Phone: 612-720-4639
Fax: 612-886-2966
www.oswellec.com
Footing elevation may vary below
slab, provide frost protection per
Code
8" thick x 18" wide minimum
unreinforced concrete strip
footing (16" wide minimum for
maximum unbalanced grade of 2'-
6" or less), larger footing width
may be required for specific soil
bearing conditions to be
determined per Code by others
6" minimum thick cast-in-place
concrete wall
#4 x 2'-0" long centered
dowels w/ 5" minimum embed
wet set or epoxy grouted in
place
32" o.c. max for sand & 24"
o.c. max for SC & clay
48" o.c. max for sand, 42" o.c.
max for SC, & 36" o.c. max for
clay
1/1/2020 3'-2" max
Wood floor & wall framing by others
Grade to be at least 6" below top of wall
BASEMENT WALL DETAIL
Table Notes:
(1) =
(2) =
Allowed alternate anchors are:
Oswell Engineering and Consulting, L.L.C.
Project Name:2020 Standardized Concrete Foundation Drawings
Description:Full Height Wall Detail (NOT TO SCALE)
Project #19.100
Client Name:Kopp Concrete Inc.
Client Address:16455 122th Street, Becker, MN 55308
34
Page S6 of S6
Continuous #4 horizontal bars, provide
at least (2) @ 8'-0" clear, (3) @ 9'-0"
clear, & (4) @ 10'-0" clear, At
contractor's option: The lowest wall
horizontal bar may be omitted if (2)#4
continuous horizontal bars are placed in
the footing
1901 E Hennepin Ave, #201
Minneapolis, MN 55413
Phone: 612-720-4639
Fax: 612-886-2966
www.oswellec.com
Unreinforced if concrete is 5000 psi or if
clear height is 4" less
Unreinforced if concrete is 4000 psi or if
clear height is 4" less
Cast-in-place concrete foundation wall
w/ #6 or equivalent vertical bars placed
1.5" from inside face, see table below for
spacing
2x6 minimum sill plate w/ 1/2" diameter
anchor bolts w/ 7" minimum embed & 2"
wide x 1/8" thick square or round
countersunk washers or alternative
anchor (Anchor bolt clearance between
edge of both wall and sill plate is to be
2.5") (see table below for spacing)
Exterior top of wall may have a brick
ledge provided the stem wall formed is
at least 6" thick & no more than 16" high
Connection of floor members to sill plate
to be per Code by others
1/1/2020 Clear Height8' or Less
Bolts
Alternate
NA
NA
36"(1)
NA
NA
Clay
9'Wall
Thickness
8"
10"
12"
#4 x 2'-0" long dowels @ 72" o.c. max w/
5" minimum embed
Sand SC Clay Sand SC
Unreinforced concrete strip footing per
Code by others, elevation below slab
may vary as required
MAB/ST, MASA/FA3, FWAZ, or 1/2"
diameter expansion bolts w/ 6" min embed
(install in accordance with the
manufacturer's recommendations)
10'
Clear Height and Soil Type
Sand SC Clay
Vertical Rebar Spacing
NA
NA
NA
NA 36"
36"(1)
NA
24"
36"
NA
36"
36"(1)
NA
36"(2)
NA
NA
NA
NA
NA
72"
48"
72"
24"
48"
18"
36"(1)
NA
NA
72"
36"
60"
24"
36"
12"
48"
18"
Sill Anchor Spacing
36"
12"
24"
8"
Beams - 10-26-2020 - GW
3-2x10 (3-8')
Dbl Jacks
(3) 9-1/2"
LVL @ 10'
Dbl Jacks
2-2x10
(1-8')
Dbl Jacks
2-2x10
(1-8')
2-2x10
(1-8')
Dbl Jacks
(3) 9-1/2"
LVL @ 9'
Dbl Jacks
2-2x10 (1-12')2-2x10
(1-8')
Dbl Jacks
2-2x10
(2-10')
2-2x6
(2-10')
2-2x6
(2-10')
(2) 11-7/8"
LVL @ 12
2-2x10
(1-8')
Dbl Jacks
2-2x10
(1-8')
Dbl Jacks
2-2x10
(1-8')
(2) 9-1/2" LSL @ 6'
Dbl Jacks
(2) 9-1/2" LVL @ 9'
Dbl Jacks
2-2x10
(2-12')
(2) 11-7/8" LSL @ 9'
Dbl Jacks
2-2x10 (1-12')2-2x10
(2-10')
(2) 9-1/2" LSL @ 6'
(2) 9-1/2" LSL @ 6'
2-2x10
(1-8')2-2x10 (1-12')(2) 11-7/8" LSL @ 22'
(2) 16" LVL @ 20'
Triple Jacks
HUC26-2Z
Hanger
2-2x8
(2-8')3-2x8 (1-10')2-2x8 (1-12')
Main Level
Member Name Results Current Solution Comments
32.5' Hip - Load Only Failed 2 piece(s) 1 3/4" x 16" 2.0E Microllam® LVL
Bed #3 Passed 2 piece(s) 1 3/4" x 9 1/2" 1.55E TimberStrand® LSL
Dining Passed 2 piece(s) 1 3/4" x 9 1/2" 2.0E Microllam® LVL
Great Room Passed 2 piece(s) 2 x 10 Spruce-Pine-Fir No. 1 / No. 2
39' Hip - Load Only Failed 2 piece(s) 1 3/4" x 16" 2.0E Microllam® LVL
Master Passed 2 piece(s) 1 3/4" x 11 7/8" 1.55E TimberStrand® LSL
Tub Passed 2 piece(s) 2 x 10 Spruce-Pine-Fir No. 1 / No. 2
WIC/Laundry Passed 2 piece(s) 2 x 10 Spruce-Pine-Fir No. 1 / No. 2
Front Passed 2 piece(s) 1 3/4" x 9 1/2" 1.55E TimberStrand® LSL
Landing Passed 2 piece(s) 1 3/4" x 9 1/2" 1.55E TimberStrand® LSL
House-Garage Passed 2 piece(s) 2 x 10 Spruce-Pine-Fir No. 1 / No. 2
Bed #2 Passed 2 piece(s) 2 x 10 Spruce-Pine-Fir No. 1 / No. 2
16' OHD - Left Passed 2 piece(s) 1 3/4" x 16" 2.0E Microllam® LVL
16' OHD - Right Passed 2 piece(s) 1 3/4" x 11 7/8" 1.55E TimberStrand® LSL
Porch Drop Beam Carried Passed 2 piece(s) 2 x 8 Spruce-Pine-Fir No. 1 / No. 2
Porch Drop Beam Carrying Passed 3 piece(s) 2 x 8 Spruce-Pine-Fir No. 1 / No. 2
Lower Level
Member Name Results Current Solution Comments
Bed #4 Passed 3 piece(s) 2 x 10 Spruce-Pine-Fir No. 1 / No. 2
Rec Room - Patio Passed 3 piece(s) 1 3/4" x 9 1/2" 2.0E Microllam® LVL
Rec Room - Left/Right Passed 2 piece(s) 2 x 10 Spruce-Pine-Fir No. 1 / No. 2
Rec Room - Center Passed 2 piece(s) 2 x 10 Spruce-Pine-Fir No. 1 / No. 2
Family Room - Rear Passed 3 piece(s) 1 3/4" x 9 1/2" 1.55E TimberStrand® LSL
Storage Passed 2 piece(s) 2 x 10 Spruce-Pine-Fir No. 1 / No. 2
Storage 3/0 Passed 2 piece(s) 2 x 10 Spruce-Pine-Fir No. 1 / No. 2
Stairway Flush Beam Passed 2 piece(s) 2 x 10 Spruce-Pine-Fir No. 1 / No. 2
Floor Drop Beam Passed 2 piece(s) 1 3/4" x 11 7/8" 2.0E Microllam® LVL
Closet 2/0 Passed 2 piece(s) 2 x 10 Spruce-Pine-Fir No. 1 / No. 2
Mech 3/0 Passed 2 piece(s) 2 x 10 Spruce-Pine-Fir No. 1 / No. 2
Bath 3/0 Passed 2 piece(s) 2 x 10 Spruce-Pine-Fir No. 1 / No. 2
Sharper - 8194 198th
JOB SUMMARY REPORT
ForteWEB Software Operator Job Notes 10/26/2020 3:13:41 PM UTCGraig Wallace
Builders FirstSource
(612) 656-1626
graig.wallace@bldr.com
ForteWEB v3.0
File Name: Sharper - 8194 198th
Sharper Homes
8194 198th St
Lakeville, MN
Page 1 / 29
Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern)
Member Reaction (lbs)4493 @ 0 4 0 8181 (5.50")Passed (55%)--1.0 D + 1.0 S (Alt Spans)
Shear (lbs)3998 @ 1 9 8 12236 Passed (33%)1.15 1.0 D + 1.0 S (Alt Spans)
Moment (Ft-lbs)35047 @ 16 3 2 35781 Passed (98%)1.15 1.0 D + 1.0 S (Alt Spans)
Live Load Defl. (in)1.750 @ 16 3 8 1.065 Failed (L/219)--1.0 D + 1.0 S (Alt Spans)
Total Load Defl. (in)2.762 @ 16 3 7 1.597 Failed (L/139)--1.0 D + 1.0 S (Alt Spans)
System : Roof
Member Type : Flush Beam
Building Use : Residential
Building Code : IBC 2015
Design Methodology : ASD
Member Pitch : 0/12
•Deflection criteria: LL (L/360) and TL (L/240).
•Overhang deflection criteria: LL (2L/360) and TL (2L/240). Upward deflection on right cantilever exceeds overhang deflection criteria.
•Allowed moment does not reflect the adjustment for the beam stability factor.
•Upward deflection on right cantilever exceeds 0.4".
• Blocking Panels are assumed to carry no loads applied directly above them and the full load is applied to the member being designed.
Bearing Length Loads to Supports (lbs)
Supports Total Available Required Dead Snow Total Accessories
1 - Stud wall - SPF 5.50"5.50"3.02"1647 2846 4493 Blocking
2 - Stud wall - SPF 5.50"5.50"2.93"1620 2738 4358 Blocking
•Maximum allowable bracing intervals based on applied load.
Lateral Bracing Bracing Intervals Comments
Top Edge (Lu)1 6 0 o/c
Bottom Edge (Lu)34 0 0 o/c
Dead Snow
Vertical Loads Location (Side)Tributary Width (0.90)(1.15)Comments
0 - Self Weight (PLF)0 0 0 to 34 0 0 N/A 16.3 --
1 - Uniform (PSF)0 0 0 to 30 6 0 (Back)3 0 0 17.0 35.0 Roof
2 - Uniform (PSF)0 0 0 to 34 0 0 (Top)2 0 0 17.0 35.0 Roof
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties
related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is
responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387
and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to
www.weyerhaeuser.com/woodproducts/document-library.
The product application, input design loads, dimensions and support information have been provided by G. Wallace
Weyerhaeuser Notes
All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal.
MEMBER REPORT FAILED
Main Level, 32.5' Hip - Load Only
2 piece(s) 1 3/4" x 16" 2.0E Microllam® LVL
ForteWEB Software Operator Job Notes 10/26/2020 3:13:41 PM UTCGraig Wallace
Builders FirstSource
(612) 656-1626
graig.wallace@bldr.com
ForteWEB v3.0, Engine: V8.1.4.2, Data: V8.0.0.0
File Name: Sharper - 8194 198th
Sharper Homes
8194 198th St
Lakeville, MN
Page 2 / 29
Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern)
Member Reaction (lbs)4048 @ 0 1 8 7613 (3.00")Passed (53%)--1.0 D + 1.0 S (All Spans)
Shear (lbs)3902 @ 1 0 8 7902 Passed (49%)1.15 1.0 D + 1.0 S (All Spans)
Moment (Ft-lbs)7310 @ 2 0 0 11985 Passed (61%)1.15 1.0 D + 1.0 S (All Spans)
Live Load Defl. (in)0.073 @ 2 8 3 0.175 Passed (L/866)--1.0 D + 1.0 S (All Spans)
Total Load Defl. (in)0.114 @ 2 8 2 0.262 Passed (L/555)--1.0 D + 1.0 S (All Spans)
System : Wall
Member Type : Header
Building Use : Residential
Building Code : IBC 2015
Design Methodology : ASD
•Deflection criteria: LL (L/360) and TL (L/240).
•Allowed moment does not reflect the adjustment for the beam stability factor.
Bearing Length Loads to Supports (lbs)
Supports Total Available Required Dead Snow Total Accessories
1 - Trimmer - SPF 3.00"3.00"1.60"1468 2580 4048 None
2 - Trimmer - SPF 3.00"3.00"1.52"1350 2508 3858 None
•Maximum allowable bracing intervals based on applied load.
Lateral Bracing Bracing Intervals Comments
Top Edge (Lu)5 6 0 o/c
Bottom Edge (Lu)5 6 0 o/c
Dead Snow
Vertical Loads Location (Side)Tributary Width (0.90)(1.15)Comments
0 - Self Weight (PLF)0 0 0 to 5 6 0 N/A 10.4 --
1 - Uniform (PSF)2 0 0 to 5 6 0 17 9 0 17.0 35.0 Roof
2 - Uniform (PSF)0 0 0 to 2 0 0 2 6 0 17.0 35.0 Roof
3 - Point (lb)2 0 0 N/A 1620 2738
Linked from: 32.5'
Hip - Load Only,
Support 2
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties
related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is
responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387
and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to
www.weyerhaeuser.com/woodproducts/document-library.
The product application, input design loads, dimensions and support information have been provided by G. Wallace
Weyerhaeuser Notes
All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal.
MEMBER REPORT PASSED
Main Level, Bed #3
2 piece(s) 1 3/4" x 9 1/2" 1.55E TimberStrand® LSL
ForteWEB Software Operator Job Notes 10/26/2020 3:13:41 PM UTCGraig Wallace
Builders FirstSource
(612) 656-1626
graig.wallace@bldr.com
ForteWEB v3.0, Engine: V8.1.4.2, Data: V8.0.0.0
File Name: Sharper - 8194 198th
Sharper Homes
8194 198th St
Lakeville, MN
Page 3 / 29
Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern)
Member Reaction (lbs)4863 @ 0 1 8 7613 (3.00")Passed (64%)--1.0 D + 1.0 S (All Spans)
Shear (lbs)3796 @ 1 0 8 7265 Passed (52%)1.15 1.0 D + 1.0 S (All Spans)
Moment (Ft-lbs)10949 @ 4 9 0 13541 Passed (81%)1.15 1.0 D + 1.0 S (All Spans)
Live Load Defl. (in)0.250 @ 4 9 0 0.308 Passed (L/444)--1.0 D + 1.0 S (All Spans)
Total Load Defl. (in)0.375 @ 4 9 0 0.463 Passed (L/296)--1.0 D + 1.0 S (All Spans)
System : Wall
Member Type : Header
Building Use : Residential
Building Code : IBC 2015
Design Methodology : ASD
•Deflection criteria: LL (L/360) and TL (L/240).
•Allowed moment does not reflect the adjustment for the beam stability factor.
Bearing Length Loads to Supports (lbs)
Supports Total Available Required Dead Snow Total Accessories
1 - Trimmer - SPF 3.00"3.00"1.92"1621 3242 4863 None
2 - Trimmer - SPF 3.00"3.00"1.92"1621 3242 4863 None
•Maximum allowable bracing intervals based on applied load.
Lateral Bracing Bracing Intervals Comments
Top Edge (Lu)9 1 0 o/c
Bottom Edge (Lu)9 6 0 o/c
Dead Snow
Vertical Loads Location (Side)Tributary Width (0.90)(1.15)Comments
0 - Self Weight (PLF)0 0 0 to 9 6 0 N/A 9.7 --
1 - Uniform (PSF)0 0 0 to 9 6 0 19 6 0 17.0 35.0 Roof
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties
related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is
responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387
and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to
www.weyerhaeuser.com/woodproducts/document-library.
The product application, input design loads, dimensions and support information have been provided by G. Wallace
Weyerhaeuser Notes
All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal.
MEMBER REPORT PASSED
Main Level, Dining
2 piece(s) 1 3/4" x 9 1/2" 2.0E Microllam® LVL
ForteWEB Software Operator Job Notes 10/26/2020 3:13:41 PM UTCGraig Wallace
Builders FirstSource
(612) 656-1626
graig.wallace@bldr.com
ForteWEB v3.0, Engine: V8.1.4.2, Data: V8.0.0.0
File Name: Sharper - 8194 198th
Sharper Homes
8194 198th St
Lakeville, MN
Page 4 / 29
Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern)
Member Reaction (lbs)1461 @ 0 0 0 1913 (1.50")Passed (76%)--1.0 D + 1.0 S (Alt Spans)
Shear (lbs)1238 @ 2 10 4 2872 Passed (43%)1.15 1.0 D + 1.0 S (Adj Spans)
Moment (Ft-lbs)-1450 @ 3 10 0 3946 Passed (37%)1.15 1.0 D + 1.0 S (Adj Spans)
Live Load Defl. (in)0.007 @ 1 9 13 0.128 Passed (L/999+)--1.0 D + 1.0 S (Alt Spans)
Total Load Defl. (in)0.010 @ 1 9 10 0.192 Passed (L/999+)--1.0 D + 1.0 S (Alt Spans)
System : Wall
Member Type : Header
Building Use : Residential
Building Code : IBC 2015
Design Methodology : ASD
•Deflection criteria: LL (L/360) and TL (L/240).
•Allowed moment does not reflect the adjustment for the beam stability factor.
•Applicable calculations are based on NDS.
Bearing Length Loads to Supports (lbs)
Supports Total Available Required Dead Snow Total Accessories
1 - Trimmer - SPF 1.50"1.50"1.50"465 996 1461 None
2 - Trimmer - SPF 5.00"5.00"3.16"1299 2728 4027 None
3 - Trimmer - SPF 5.00"5.00"3.16"1299 2728 4027 None
4 - Trimmer - SPF 1.50"1.50"1.50"465 996 1461 None
•Maximum allowable bracing intervals based on applied load.
Lateral Bracing Bracing Intervals Comments
Top Edge (Lu)11 7 0 o/c
Bottom Edge (Lu)11 7 0 o/c
Dead Snow
Vertical Loads Location (Side)Tributary Width (0.90)(1.15)Comments
0 - Self Weight (PLF)0 0 0 to 11 7 0 N/A 7.0 --
1 - Uniform (PSF)0 0 0 to 11 7 0 17 6 0 17.0 35.0 Roof
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties
related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is
responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387
and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to
www.weyerhaeuser.com/woodproducts/document-library.
The product application, input design loads, dimensions and support information have been provided by G. Wallace
Weyerhaeuser Notes
All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal.
MEMBER REPORT PASSED
Main Level, Great Room
2 piece(s) 2 x 10 Spruce-Pine-Fir No. 1 / No. 2
ForteWEB Software Operator Job Notes 10/26/2020 3:13:41 PM UTCGraig Wallace
Builders FirstSource
(612) 656-1626
graig.wallace@bldr.com
ForteWEB v3.0, Engine: V8.1.4.2, Data: V8.0.0.0
File Name: Sharper - 8194 198th
Sharper Homes
8194 198th St
Lakeville, MN
Page 5 / 29
Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern)
Member Reaction (lbs)5258 @ 1 8 12 8181 (5.50")Passed (64%)--1.0 D + 1.0 S (Adj Spans)
Shear (lbs)4862 @ 3 3 8 12236 Passed (40%)1.15 1.0 D + 1.0 S (Adj Spans)
Moment (Ft-lbs)50938 @ 21 0 0 35781 Failed (142%)1.15 1.0 D + 1.0 S (Alt Spans)
Live Load Defl. (in)3.674 @ 21 0 0 1.285 Failed (L/126)--1.0 D + 1.0 S (Alt Spans)
Total Load Defl. (in)5.797 @ 21 0 0 1.927 Failed (L/80)--1.0 D + 1.0 S (Alt Spans)
System : Roof
Member Type : Flush Beam
Building Use : Residential
Building Code : IBC 2015
Design Methodology : ASD
Member Pitch : 0/12
•Deflection criteria: LL (L/360) and TL (L/240).
•Overhang deflection criteria: LL (2L/360) and TL (2L/240). Upward deflection on left and right cantilevers exceeds overhang deflection criteria.
•Allowed moment does not reflect the adjustment for the beam stability factor.
•Upward deflection on left and right cantilevers exceeds 0.4".
• Blocking Panels are assumed to carry no loads applied directly above them and the full load is applied to the member being designed.
Bearing Length Loads to Supports (lbs)
Supports Total Available Required Dead Snow Total Accessories
1 - Stud wall - SPF 5.50"5.50"3.54"1950 3309 5259 Blocking
2 - Stud wall - SPF 5.50"5.50"3.54"1950 3309 5259 Blocking
•Maximum allowable bracing intervals based on applied load.
Lateral Bracing Bracing Intervals Comments
Top Edge (Lu)0 6 0 o/c
Bottom Edge (Lu)34 5 0 o/c
Dead Snow
Vertical Loads Location (Side)Tributary Width (0.90)(1.15)Comments
0 - Self Weight (PLF)0 0 0 to 42 0 0 N/A 16.3 --
1 - Uniform (PSF)3 6 0 to 38 6 0 (Front)3 0 0 17.0 35.0 Roof
2 - Uniform (PSF)0 0 0 to 42 0 0 (Top)2 0 0 17.0 35.0 Roof
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties
related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is
responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387
and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to
www.weyerhaeuser.com/woodproducts/document-library.
The product application, input design loads, dimensions and support information have been provided by G. Wallace
Weyerhaeuser Notes
All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal.
MEMBER REPORT FAILED
Main Level, 39' Hip - Load Only
2 piece(s) 1 3/4" x 16" 2.0E Microllam® LVL
ForteWEB Software Operator Job Notes 10/26/2020 3:13:41 PM UTCGraig Wallace
Builders FirstSource
(612) 656-1626
graig.wallace@bldr.com
ForteWEB v3.0, Engine: V8.1.4.2, Data: V8.0.0.0
File Name: Sharper - 8194 198th
Sharper Homes
8194 198th St
Lakeville, MN
Page 6 / 29
Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern)
Member Reaction (lbs)6699 @ 0 1 8 7613 (3.00")Passed (88%)--1.0 D + 1.0 S (All Spans)
Shear (lbs)6522 @ 1 2 14 9878 Passed (66%)1.15 1.0 D + 1.0 S (All Spans)
Moment (Ft-lbs)14442 @ 3 3 2 18346 Passed (79%)1.15 1.0 D + 1.0 S (All Spans)
Live Load Defl. (in)0.183 @ 4 1 7 0.275 Passed (L/542)--1.0 D + 1.0 S (All Spans)
Total Load Defl. (in)0.281 @ 4 1 6 0.412 Passed (L/352)--1.0 D + 1.0 S (All Spans)
System : Wall
Member Type : Header
Building Use : Residential
Building Code : IBC 2015
Design Methodology : ASD
•Deflection criteria: LL (L/360) and TL (L/240).
•Allowed moment does not reflect the adjustment for the beam stability factor.
Bearing Length Loads to Supports (lbs)
Supports Total Available Required Dead Snow Total Accessories
1 - Trimmer - SPF 3.00"3.00"2.64"2399 4301 6700 None
2 - Trimmer - SPF 3.00"3.00"2.28"1989 3799 5788 None
•Maximum allowable bracing intervals based on applied load.
Lateral Bracing Bracing Intervals Comments
Top Edge (Lu)6 3 0 o/c
Bottom Edge (Lu)8 6 0 o/c
Dead Snow
Vertical Loads Location (Side)Tributary Width (0.90)(1.15)Comments
0 - Self Weight (PLF)0 0 0 to 8 6 0 N/A 13.0 --
1 - Uniform (PSF)0 0 0 to 2 3 0 2 6 0 17.0 35.0 Roof
2 - Uniform (PSF)2 3 0 to 8 6 0 21 0 0 17.0 35.0 Roof
3 - Point (lb)2 3 0 N/A 1950 3309
Linked from: 39'
Hip - Load Only,
Support 1
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties
related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is
responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387
and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to
www.weyerhaeuser.com/woodproducts/document-library.
The product application, input design loads, dimensions and support information have been provided by G. Wallace
Weyerhaeuser Notes
All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal.
MEMBER REPORT PASSED
Main Level, Master
2 piece(s) 1 3/4" x 11 7/8" 1.55E TimberStrand® LSL
ForteWEB Software Operator Job Notes 10/26/2020 3:13:41 PM UTCGraig Wallace
Builders FirstSource
(612) 656-1626
graig.wallace@bldr.com
ForteWEB v3.0, Engine: V8.1.4.2, Data: V8.0.0.0
File Name: Sharper - 8194 198th
Sharper Homes
8194 198th St
Lakeville, MN
Page 7 / 29
Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern)
Member Reaction (lbs)633 @ 0 0 0 1913 (1.50")Passed (33%)--1.0 D + 1.0 S (All Spans)
Shear (lbs)417 @ 0 10 12 2872 Passed (15%)1.15 1.0 D + 1.0 S (All Spans)
Moment (Ft-lbs)830 @ 2 7 8 3946 Passed (21%)1.15 1.0 D + 1.0 S (All Spans)
Live Load Defl. (in)0.010 @ 2 7 8 0.175 Passed (L/999+)--1.0 D + 1.0 S (All Spans)
Total Load Defl. (in)0.015 @ 2 7 8 0.262 Passed (L/999+)--1.0 D + 1.0 S (All Spans)
System : Wall
Member Type : Header
Building Use : Residential
Building Code : IBC 2015
Design Methodology : ASD
•Deflection criteria: LL (L/360) and TL (L/240).
•Allowed moment does not reflect the adjustment for the beam stability factor.
•Applicable calculations are based on NDS.
Bearing Length Loads to Supports (lbs)
Supports Total Available Required Dead Snow Total Accessories
1 - Trimmer - SPF 1.50"1.50"1.50"219 413 632 None
2 - Trimmer - SPF 1.50"1.50"1.50"219 413 632 None
•Maximum allowable bracing intervals based on applied load.
Lateral Bracing Bracing Intervals Comments
Top Edge (Lu)5 3 0 o/c
Bottom Edge (Lu)5 3 0 o/c
Dead Snow
Vertical Loads Location (Side)Tributary Width (0.90)(1.15)Comments
0 - Self Weight (PLF)0 0 0 to 5 3 0 N/A 7.0 --
1 - Uniform (PSF)0 0 0 to 5 3 0 4 6 0 17.0 35.0 Roof
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties
related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is
responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387
and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to
www.weyerhaeuser.com/woodproducts/document-library.
The product application, input design loads, dimensions and support information have been provided by G. Wallace
Weyerhaeuser Notes
All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal.
MEMBER REPORT PASSED
Main Level, Tub
2 piece(s) 2 x 10 Spruce-Pine-Fir No. 1 / No. 2
ForteWEB Software Operator Job Notes 10/26/2020 3:13:41 PM UTCGraig Wallace
Builders FirstSource
(612) 656-1626
graig.wallace@bldr.com
ForteWEB v3.0, Engine: V8.1.4.2, Data: V8.0.0.0
File Name: Sharper - 8194 198th
Sharper Homes
8194 198th St
Lakeville, MN
Page 8 / 29
Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern)
Member Reaction (lbs)1328 @ 0 0 0 1913 (1.50")Passed (69%)--1.0 D + 1.0 S (Alt Spans)
Shear (lbs)780 @ 1 10 4 2872 Passed (27%)1.15 1.0 D + 1.0 S (Adj Spans)
Moment (Ft-lbs)-1259 @ 3 0 8 3946 Passed (32%)1.15 1.0 D + 1.0 S (Adj Spans)
Live Load Defl. (in)0.003 @ 1 5 0 0.101 Passed (L/999+)--1.0 D + 1.0 S (Alt Spans)
Total Load Defl. (in)0.004 @ 1 4 12 0.152 Passed (L/999+)--1.0 D + 1.0 S (Alt Spans)
System : Wall
Member Type : Header
Building Use : Residential
Building Code : IBC 2015
Design Methodology : ASD
•Deflection criteria: LL (L/360) and TL (L/240).
•Allowed moment does not reflect the adjustment for the beam stability factor.
•Applicable calculations are based on NDS.
Bearing Length Loads to Supports (lbs)
Supports Total Available Required Dead Snow Total Accessories
1 - Trimmer - SPF 1.50"1.50"1.50"417 911 1328 None
2 - Trimmer - SPF 10.00"10.00"3.24"1362 2766 4128 None
3 - Trimmer - SPF 10.00"10.00"5.50"2505 4502 7007 None
4 - Trimmer - SPF 1.50"1.50"1.50"18 87/-56 105/-56 None
•Maximum allowable bracing intervals based on applied load.
Lateral Bracing Bracing Intervals Comments
Top Edge (Lu)9 5 0 o/c
Bottom Edge (Lu)9 5 0 o/c
Dead Snow
Vertical Loads Location (Side)Tributary Width (0.90)(1.15)Comments
0 - Self Weight (PLF)0 0 0 to 9 5 0 N/A 7.0 --
1 - Uniform (PSF)0 0 0 to 6 0 0 21 0 0 17.0 35.0 Roof
2 - Uniform (PSF)6 0 0 to 9 5 0 2 6 0 17.0 35.0 Roof
3 - Point (lb)6 0 0 N/A 1950 3309
Linked from: 39'
Hip - Load Only,
Support 2
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties
related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is
responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387
and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to
www.weyerhaeuser.com/woodproducts/document-library.
The product application, input design loads, dimensions and support information have been provided by G. Wallace
Weyerhaeuser Notes
All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal.
MEMBER REPORT PASSED
Main Level, WIC/Laundry
2 piece(s) 2 x 10 Spruce-Pine-Fir No. 1 / No. 2
ForteWEB Software Operator Job Notes 10/26/2020 3:13:41 PM UTCGraig Wallace
Builders FirstSource
(612) 656-1626
graig.wallace@bldr.com
ForteWEB v3.0, Engine: V8.1.4.2, Data: V8.0.0.0
File Name: Sharper - 8194 198th
Sharper Homes
8194 198th St
Lakeville, MN
Page 9 / 29
Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern)
Member Reaction (lbs)2703 @ 5 10 8 7613 (3.00")Passed (36%)--1.0 D + 1.0 S (All Spans)
Shear (lbs)1718 @ 4 11 8 7902 Passed (22%)1.15 1.0 D + 1.0 S (All Spans)
Moment (Ft-lbs)3573 @ 3 0 7 11985 Passed (30%)1.15 1.0 D + 1.0 S (All Spans)
Live Load Defl. (in)0.047 @ 3 0 3 0.192 Passed (L/999+)--1.0 D + 1.0 S (All Spans)
Total Load Defl. (in)0.071 @ 3 0 3 0.287 Passed (L/972)--1.0 D + 1.0 S (All Spans)
System : Wall
Member Type : Header
Building Use : Residential
Building Code : IBC 2015
Design Methodology : ASD
•Deflection criteria: LL (L/360) and TL (L/240).
•Allowed moment does not reflect the adjustment for the beam stability factor.
Bearing Length Loads to Supports (lbs)
Supports Total Available Required Dead Snow Total Accessories
1 - Trimmer - SPF 3.00"3.00"1.50"858 1701 2559 None
2 - Trimmer - SPF 3.00"3.00"1.50"905 1799 2704 None
•Maximum allowable bracing intervals based on applied load.
Lateral Bracing Bracing Intervals Comments
Top Edge (Lu)6 0 0 o/c
Bottom Edge (Lu)6 0 0 o/c
Dead Snow
Vertical Loads Location (Side)Tributary Width (0.90)(1.15)Comments
0 - Self Weight (PLF)0 0 0 to 6 0 0 N/A 10.4 --
1 - Uniform (PSF)0 0 0 to 4 0 0 16 0 0 17.0 35.0 Roof
2 - Uniform (PSF)4 0 0 to 6 0 0 18 0 0 17.0 35.0 Roof
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties
related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is
responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387
and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to
www.weyerhaeuser.com/woodproducts/document-library.
The product application, input design loads, dimensions and support information have been provided by G. Wallace
Weyerhaeuser Notes
All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal.
MEMBER REPORT PASSED
Main Level, Front
2 piece(s) 1 3/4" x 9 1/2" 1.55E TimberStrand® LSL
ForteWEB Software Operator Job Notes 10/26/2020 3:13:41 PM UTCGraig Wallace
Builders FirstSource
(612) 656-1626
graig.wallace@bldr.com
ForteWEB v3.0, Engine: V8.1.4.2, Data: V8.0.0.0
File Name: Sharper - 8194 198th
Sharper Homes
8194 198th St
Lakeville, MN
Page 10 / 29
Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern)
Member Reaction (lbs)3425 @ 0 1 8 7613 (3.00")Passed (45%)--1.0 D + 1.0 S (All Spans)
Shear (lbs)2128 @ 1 0 8 7902 Passed (27%)1.15 1.0 D + 1.0 S (All Spans)
Moment (Ft-lbs)4291 @ 2 9 0 11985 Passed (36%)1.15 1.0 D + 1.0 S (All Spans)
Live Load Defl. (in)0.049 @ 2 9 0 0.175 Passed (L/999+)--1.0 D + 1.0 S (All Spans)
Total Load Defl. (in)0.074 @ 2 9 0 0.262 Passed (L/850)--1.0 D + 1.0 S (All Spans)
System : Wall
Member Type : Header
Building Use : Residential
Building Code : IBC 2015
Design Methodology : ASD
•Deflection criteria: LL (L/360) and TL (L/240).
•Allowed moment does not reflect the adjustment for the beam stability factor.
Bearing Length Loads to Supports (lbs)
Supports Total Available Required Dead Snow Total Accessories
1 - Trimmer - SPF 3.00"3.00"1.50"1139 2286 3425 None
2 - Trimmer - SPF 3.00"3.00"1.50"1139 2286 3425 None
•Maximum allowable bracing intervals based on applied load.
Lateral Bracing Bracing Intervals Comments
Top Edge (Lu)5 6 0 o/c
Bottom Edge (Lu)5 6 0 o/c
Dead Snow
Vertical Loads Location (Side)Tributary Width (0.90)(1.15)Comments
0 - Self Weight (PLF)0 0 0 to 5 6 0 N/A 10.4 --
1 - Uniform (PSF)0 0 0 to 5 6 0 23 9 0 17.0 35.0 Roof
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties
related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is
responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387
and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to
www.weyerhaeuser.com/woodproducts/document-library.
The product application, input design loads, dimensions and support information have been provided by G. Wallace
Weyerhaeuser Notes
All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal.
MEMBER REPORT PASSED
Main Level, Landing
2 piece(s) 1 3/4" x 9 1/2" 1.55E TimberStrand® LSL
ForteWEB Software Operator Job Notes 10/26/2020 3:13:41 PM UTCGraig Wallace
Builders FirstSource
(612) 656-1626
graig.wallace@bldr.com
ForteWEB v3.0, Engine: V8.1.4.2, Data: V8.0.0.0
File Name: Sharper - 8194 198th
Sharper Homes
8194 198th St
Lakeville, MN
Page 11 / 29
Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern)
Member Reaction (lbs)1611 @ 0 0 0 1913 (1.50")Passed (84%)--1.0 D + 1.0 S (All Spans)
Shear (lbs)766 @ 0 10 12 2872 Passed (27%)1.15 1.0 D + 1.0 S (All Spans)
Moment (Ft-lbs)1376 @ 1 8 8 3946 Passed (35%)1.15 1.0 D + 1.0 S (All Spans)
Live Load Defl. (in)0.007 @ 1 8 8 0.114 Passed (L/999+)--1.0 D + 1.0 S (All Spans)
Total Load Defl. (in)0.010 @ 1 8 8 0.171 Passed (L/999+)--1.0 D + 1.0 S (All Spans)
System : Wall
Member Type : Header
Building Use : Residential
Building Code : IBC 2015
Design Methodology : ASD
•Deflection criteria: LL (L/360) and TL (L/240).
•Allowed moment does not reflect the adjustment for the beam stability factor.
•Applicable calculations are based on NDS.
Bearing Length Loads to Supports (lbs)
Supports Total Available Required Dead Snow Total Accessories
1 - Trimmer - SPF 1.50"1.50"1.50"535 1076 1611 None
2 - Trimmer - SPF 1.50"1.50"1.50"535 1076 1611 None
•Maximum allowable bracing intervals based on applied load.
Lateral Bracing Bracing Intervals Comments
Top Edge (Lu)3 5 0 o/c
Bottom Edge (Lu)3 5 0 o/c
Dead Snow
Vertical Loads Location (Side)Tributary Width (0.90)(1.15)Comments
0 - Self Weight (PLF)0 0 0 to 3 5 0 N/A 7.0 --
1 - Uniform (PSF)0 0 0 to 3 5 0 18 0 0 17.0 35.0 Roof
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties
related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is
responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387
and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to
www.weyerhaeuser.com/woodproducts/document-library.
The product application, input design loads, dimensions and support information have been provided by G. Wallace
Weyerhaeuser Notes
All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal.
MEMBER REPORT PASSED
Main Level, House-Garage
2 piece(s) 2 x 10 Spruce-Pine-Fir No. 1 / No. 2
ForteWEB Software Operator Job Notes 10/26/2020 3:13:41 PM UTCGraig Wallace
Builders FirstSource
(612) 656-1626
graig.wallace@bldr.com
ForteWEB v3.0, Engine: V8.1.4.2, Data: V8.0.0.0
File Name: Sharper - 8194 198th
Sharper Homes
8194 198th St
Lakeville, MN
Page 12 / 29
Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern)
Member Reaction (lbs)633 @ 0 0 0 1913 (1.50")Passed (33%)--1.0 D + 1.0 S (All Spans)
Shear (lbs)417 @ 0 10 12 2872 Passed (15%)1.15 1.0 D + 1.0 S (All Spans)
Moment (Ft-lbs)830 @ 2 7 8 3946 Passed (21%)1.15 1.0 D + 1.0 S (All Spans)
Live Load Defl. (in)0.010 @ 2 7 8 0.175 Passed (L/999+)--1.0 D + 1.0 S (All Spans)
Total Load Defl. (in)0.015 @ 2 7 8 0.262 Passed (L/999+)--1.0 D + 1.0 S (All Spans)
System : Wall
Member Type : Header
Building Use : Residential
Building Code : IBC 2015
Design Methodology : ASD
•Deflection criteria: LL (L/360) and TL (L/240).
•Allowed moment does not reflect the adjustment for the beam stability factor.
•Applicable calculations are based on NDS.
Bearing Length Loads to Supports (lbs)
Supports Total Available Required Dead Snow Total Accessories
1 - Trimmer - SPF 1.50"1.50"1.50"219 413 632 None
2 - Trimmer - SPF 1.50"1.50"1.50"219 413 632 None
•Maximum allowable bracing intervals based on applied load.
Lateral Bracing Bracing Intervals Comments
Top Edge (Lu)5 3 0 o/c
Bottom Edge (Lu)5 3 0 o/c
Dead Snow
Vertical Loads Location (Side)Tributary Width (0.90)(1.15)Comments
0 - Self Weight (PLF)0 0 0 to 5 3 0 N/A 7.0 --
1 - Uniform (PSF)0 0 0 to 5 3 0 4 6 0 17.0 35.0 Roof
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties
related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is
responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387
and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to
www.weyerhaeuser.com/woodproducts/document-library.
The product application, input design loads, dimensions and support information have been provided by G. Wallace
Weyerhaeuser Notes
All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal.
MEMBER REPORT PASSED
Main Level, Bed #2
2 piece(s) 2 x 10 Spruce-Pine-Fir No. 1 / No. 2
ForteWEB Software Operator Job Notes 10/26/2020 3:13:41 PM UTCGraig Wallace
Builders FirstSource
(612) 656-1626
graig.wallace@bldr.com
ForteWEB v3.0, Engine: V8.1.4.2, Data: V8.0.0.0
File Name: Sharper - 8194 198th
Sharper Homes
8194 198th St
Lakeville, MN
Page 13 / 29
Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern)
Member Reaction (lbs)8430 @ 18 5 12 11419 (4.50")Passed (74%)--1.0 D + 1.0 S (Adj Spans)
Shear (lbs)7685 @ 3 4 8 12236 Passed (63%)1.15 1.0 D + 1.0 S (Adj Spans)
Moment (Ft-lbs)36269 @ 9 4 5 35781 Passed (101%)1.15 1.0 D + 1.0 S (Alt Spans)
Live Load Defl. (in)0.542 @ 10 0 6 0.554 Passed (L/368)--1.0 D + 1.0 S (Alt Spans)
Total Load Defl. (in)0.833 @ 10 0 4 0.831 Passed (L/240)--1.0 D + 1.0 S (Alt Spans)
System : Wall
Member Type : Header
Building Use : Residential
Building Code : IBC 2015
Design Methodology : ASD
•Deflection criteria: LL (L/360) and TL (L/240).
•Overhang deflection criteria: LL (2L/360) and TL (2L/240). Upward deflection on left cantilever exceeds overhang deflection criteria.
•Allowed moment does not reflect the adjustment for the beam stability factor.
Bearing Length Loads to Supports (lbs)
Supports Total Available Required Dead Snow Total Accessories
1 - Trimmer - SPF 4.50"4.50"3.22"2933 5246 8179 None
2 - Trimmer - SPF 4.50"4.50"3.32"2899 5531 8430 None
•Maximum allowable bracing intervals based on applied load.
Lateral Bracing Bracing Intervals Comments
Top Edge (Lu)0 6 0 o/c
Bottom Edge (Lu)19 0 0 o/c
Dead Snow
Vertical Loads Location (Side)Tributary Width (0.90)(1.15)Comments
0 - Self Weight (PLF)0 0 0 to 19 0 0 N/A 16.3 --
1 - Uniform (PSF)0 0 0 to 6 0 0 2 6 0 17.0 35.0 Roof
2 - Uniform (PSF)6 0 0 to 19 0 0 16 6 0 17.0 35.0 Roof
3 - Point (lb)6 0 0 N/A 1620 2738
Linked from: 32.5'
Hip - Load Only,
Support 2
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties
related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is
responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387
and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to
www.weyerhaeuser.com/woodproducts/document-library.
The product application, input design loads, dimensions and support information have been provided by G. Wallace
Weyerhaeuser Notes
All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal.
MEMBER REPORT PASSED
Main Level, 16' OHD - Left
2 piece(s) 1 3/4" x 16" 2.0E Microllam® LVL
ForteWEB Software Operator Job Notes 10/26/2020 3:13:41 PM UTCGraig Wallace
Builders FirstSource
(612) 656-1626
graig.wallace@bldr.com
ForteWEB v3.0, Engine: V8.1.4.2, Data: V8.0.0.0
File Name: Sharper - 8194 198th
Sharper Homes
8194 198th St
Lakeville, MN
Page 14 / 29
Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern)
Member Reaction (lbs)1592 @ 2 6 0 7613 (3.00")Passed (21%)--1.0 D + 1.0 S (Adj Spans)
Shear (lbs)1118 @ 3 7 6 9878 Passed (11%)1.15 1.0 D + 1.0 S (Adj Spans)
Moment (Ft-lbs)5139 @ 10 9 0 18346 Passed (28%)1.15 1.0 D + 1.0 S (Alt Spans)
Live Load Defl. (in)0.154 @ 10 9 0 0.550 Passed (L/999+)--1.0 D + 1.0 S (Alt Spans)
Total Load Defl. (in)0.346 @ 10 9 0 0.825 Passed (L/572)--1.0 D + 1.0 S (Alt Spans)
System : Wall
Member Type : Header
Building Use : Residential
Building Code : IBC 2015
Design Methodology : ASD
•Deflection criteria: LL (L/360) and TL (L/240).
•Overhang deflection criteria: LL (2L/360) and TL (2L/240).
•Allowed moment does not reflect the adjustment for the beam stability factor.
Bearing Length Loads to Supports (lbs)
Supports Total Available Required Dead Snow Total Accessories
1 - Trimmer - SPF 3.00"3.00"1.50"833 759 1592 None
2 - Trimmer - SPF 3.00"3.00"1.50"833 759 1592 None
•Maximum allowable bracing intervals based on applied load.
Lateral Bracing Bracing Intervals Comments
Top Edge (Lu)21 6 0 o/c
Bottom Edge (Lu)21 6 0 o/c
Dead Snow
Vertical Loads Location (Side)Tributary Width (0.90)(1.15)Comments
0 - Self Weight (PLF)0 0 0 to 21 6 0 N/A 13.0 --
1 - Uniform (PSF)0 0 0 to 21 6 0 2 0 0 17.0 35.0 Roof - High
2 - Tapered (PLF)0 0 0 to 10 9 0 N/A 6.0 to 55.0 -Gable
3 - Tapered (PLF)10 9 0 to 21 6 0 N/A 55.0 to 6.0 -Gable
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties
related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is
responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387
and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to
www.weyerhaeuser.com/woodproducts/document-library.
The product application, input design loads, dimensions and support information have been provided by G. Wallace
Weyerhaeuser Notes
All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal.
MEMBER REPORT PASSED
Main Level, 16' OHD - Right
2 piece(s) 1 3/4" x 11 7/8" 1.55E TimberStrand® LSL
ForteWEB Software Operator Job Notes 10/26/2020 3:13:41 PM UTCGraig Wallace
Builders FirstSource
(612) 656-1626
graig.wallace@bldr.com
ForteWEB v3.0, Engine: V8.1.4.2, Data: V8.0.0.0
File Name: Sharper - 8194 198th
Sharper Homes
8194 198th St
Lakeville, MN
Page 15 / 29
Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern)
Member Reaction (lbs)778 @ 6 10 0 1913 (1.50")Passed (41%)--1.0 D + 1.0 S (All Spans)
Shear (lbs)634 @ 6 2 12 2251 Passed (28%)1.15 1.0 D + 1.0 S (All Spans)
Moment (Ft-lbs)1265 @ 3 7 0 2645 Passed (48%)1.15 1.0 D + 1.0 S (All Spans)
Live Load Defl. (in)0.047 @ 3 7 0 0.217 Passed (L/999+)--1.0 D + 1.0 S (All Spans)
Total Load Defl. (in)0.072 @ 3 7 0 0.325 Passed (L/999+)--1.0 D + 1.0 S (All Spans)
System : Roof
Member Type : Drop Beam
Building Use : Residential
Building Code : IBC 2015
Design Methodology : ASD
Member Pitch : 0/12
•Deflection criteria: LL (L/360) and TL (L/240).
•Allowed moment does not reflect the adjustment for the beam stability factor.
•Applicable calculations are based on NDS.
• At hanger supports, the Total Bearing dimension is equal to the width of the material that is supporting the hanger
• ¹ See Connector grid below for additional information and/or requirements.
Bearing Length Loads to Supports (lbs)
Supports Total Available Required Dead Snow Total Accessories
1 - Column - SYP 5.50"5.50"1.50"294 564 858 None
2 - Hanger on 7 1/4" SPF beam 2.00"Hanger¹1.50"279 538 817 See note ¹
•Maximum allowable bracing intervals based on applied load.
Lateral Bracing Bracing Intervals Comments
Top Edge (Lu)6 10 0 o/c
Bottom Edge (Lu)6 10 0 o/c
Connector: Simpson Strong-Tie
Support Model Seat Length Top Fasteners Face Fasteners Member Fasteners Accessories
2 - Face Mount Hanger LUS26-2 2.00"N/A 4-10d 4-10d
•Refer to manufacturer notes and instructions for proper installation and use of all connectors.
Dead Snow
Vertical Loads Location (Side)Tributary Width (0.90)(1.15)Comments
0 - Self Weight (PLF)0 0 0 to 6 10 0 N/A 5.5 --
1 - Uniform (PSF)0 0 0 to 7 0 0 (Top)4 6 0 17.0 35.0 Roof
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties
related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is
responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387
and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to
www.weyerhaeuser.com/woodproducts/document-library.
The product application, input design loads, dimensions and support information have been provided by G. Wallace
Weyerhaeuser Notes
All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal.
MEMBER REPORT PASSED
Main Level, Porch Drop Beam Carried
2 piece(s) 2 x 8 Spruce-Pine-Fir No. 1 / No. 2
ForteWEB Software Operator Job Notes 10/26/2020 3:13:41 PM UTCGraig Wallace
Builders FirstSource
(612) 656-1626
graig.wallace@bldr.com
ForteWEB v3.0, Engine: V8.1.4.2, Data: V8.0.0.0
File Name: Sharper - 8194 198th
Sharper Homes
8194 198th St
Lakeville, MN
Page 16 / 29
Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern)
Member Reaction (lbs)1233 @ 8 1 8 5738 (3.00")Passed (21%)--1.0 D + 1.0 S (All Spans)
Shear (lbs)1540 @ 1 0 12 3377 Passed (46%)1.15 1.0 D + 1.0 S (All Spans)
Moment (Ft-lbs)2979 @ 3 4 15 3967 Passed (75%)1.15 1.0 D + 1.0 S (All Spans)
Live Load Defl. (in)0.107 @ 4 1 3 0.260 Passed (L/876)--1.0 D + 1.0 S (All Spans)
Total Load Defl. (in)0.163 @ 4 1 3 0.390 Passed (L/573)--1.0 D + 1.0 S (All Spans)
System : Roof
Member Type : Drop Beam
Building Use : Residential
Building Code : IBC 2015
Design Methodology : ASD
Member Pitch : 0/12
•Deflection criteria: LL (L/360) and TL (L/240).
•Allowed moment does not reflect the adjustment for the beam stability factor.
•Applicable calculations are based on NDS.
Bearing Length Loads to Supports (lbs)
Supports Total Available Required Dead Snow Total Accessories
1 - Column - SYP 5.50"5.50"1.50"656 1251 1907 None
2 - Trimmer - SPF 3.00"3.00"1.50"428 805 1233 None
•Maximum allowable bracing intervals based on applied load.
Lateral Bracing Bracing Intervals Comments
Top Edge (Lu)8 3 0 o/c
Bottom Edge (Lu)8 3 0 o/c
Dead Snow
Vertical Loads Location (Side)Tributary Width (0.90)(1.15)Comments
0 - Self Weight (PLF)0 0 0 to 8 3 0 N/A 8.3 --
1 - Uniform (PSF)0 0 0 to 2 3 0 (Top)6 6 0 17.0 35.0 Roof
2 - Uniform (PSF)2 3 0 to 8 0 0 (Top)5 0 0 17.0 35.0 Roof
3 - Point (lb)2 3 0 (Back)N/A 279 538
Linked from: Porch
Drop Beam Carried,
Support 2
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties
related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is
responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387
and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to
www.weyerhaeuser.com/woodproducts/document-library.
The product application, input design loads, dimensions and support information have been provided by G. Wallace
Weyerhaeuser Notes
All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal.
MEMBER REPORT PASSED
Main Level, Porch Drop Beam Carrying
3 piece(s) 2 x 8 Spruce-Pine-Fir No. 1 / No. 2
ForteWEB Software Operator Job Notes 10/26/2020 3:13:41 PM UTCGraig Wallace
Builders FirstSource
(612) 656-1626
graig.wallace@bldr.com
ForteWEB v3.0, Engine: V8.1.4.2, Data: V8.0.0.0
File Name: Sharper - 8194 198th
Sharper Homes
8194 198th St
Lakeville, MN
Page 17 / 29
Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern)
Member Reaction (lbs)5223 @ 0 1 8 5738 (3.00")Passed (91%)--1.0 D + 0.75 L + 0.75 S (All Spans)
Shear (lbs)1350 @ 1 0 4 3746 Passed (36%)1.00 1.0 D + 1.0 L (All Spans)
Moment (Ft-lbs)2691 @ 2 9 0 5147 Passed (52%)1.00 1.0 D + 1.0 L (All Spans)
Live Load Defl. (in)0.020 @ 2 9 0 0.150 Passed (L/999+)--1.0 D + 1.0 L (All Spans)
Total Load Defl. (in)0.032 @ 2 9 0 0.262 Passed (L/999+)--1.0 D + 1.0 L (All Spans)
System : Wall
Member Type : Header
Building Use : Residential
Building Code : IBC 2015
Design Methodology : ASD
•Deflection criteria: LL (L/420) and TL (L/240).
•Allowed moment does not reflect the adjustment for the beam stability factor.
•Applicable calculations are based on NDS.
Bearing Length Loads to Supports (lbs)
Supports Total Available Required Dead Floor Live Snow Total Accessories
1 - Trimmer - SPF 3.00"3.00"2.73"2305 1311 2580 6196 None
2 - Trimmer - SPF 3.00"3.00"2.64"2187 1311 2508 6006 None
•Maximum allowable bracing intervals based on applied load.
Lateral Bracing Bracing Intervals Comments
Top Edge (Lu)5 6 0 o/c
Bottom Edge (Lu)5 6 0 o/c
Dead Floor Live Snow
Vertical Loads Location (Side)Tributary Width (0.90)(1.00)(1.15)Comments
0 - Self Weight (PLF)0 0 0 to 5 6 0 N/A 10.6 ----
1 - Uniform (PSF)0 0 0 to 5 6 0 11 11 0 15.0 40.0 -Residential - Living
Areas
2 - Uniform (PLF)0 0 0 to 5 6 0 N/A 115.0 --Wall
3 - Point (lb)0 1 8 N/A 1468 -2580 Linked from: Bed
#3, Support 1
4 - Point (lb)5 4 8 N/A 1350 -2508 Linked from: Bed
#3, Support 2
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties
related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is
responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387
and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to
www.weyerhaeuser.com/woodproducts/document-library.
The product application, input design loads, dimensions and support information have been provided by G. Wallace
Weyerhaeuser Notes
All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal.
MEMBER REPORT PASSED
Lower Level, Bed #4
3 piece(s) 2 x 10 Spruce-Pine-Fir No. 1 / No. 2
ForteWEB Software Operator Job Notes 10/26/2020 3:13:41 PM UTCGraig Wallace
Builders FirstSource
(612) 656-1626
graig.wallace@bldr.com
ForteWEB v3.0, Engine: V8.1.4.2, Data: V8.0.0.0
File Name: Sharper - 8194 198th
Sharper Homes
8194 198th St
Lakeville, MN
Page 18 / 29
Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern)
Member Reaction (lbs)8898 @ 0 1 8 11419 (3.00")Passed (78%)--1.0 D + 0.75 L + 0.75 S (All Spans)
Shear (lbs)5096 @ 1 0 8 9476 Passed (54%)1.00 1.0 D + 1.0 L (All Spans)
Moment (Ft-lbs)13908 @ 4 8 7 17662 Passed (79%)1.00 1.0 D + 1.0 L (All Spans)
Live Load Defl. (in)0.219 @ 4 9 1 0.264 Passed (L/507)--1.0 D + 1.0 L (All Spans)
Total Load Defl. (in)0.319 @ 4 8 14 0.463 Passed (L/348)--1.0 D + 1.0 L (All Spans)
System : Wall
Member Type : Header
Building Use : Residential
Building Code : IBC 2015
Design Methodology : ASD
•Deflection criteria: LL (L/420) and TL (L/240).
•Allowed moment does not reflect the adjustment for the beam stability factor.
Bearing Length Loads to Supports (lbs)
Supports Total Available Required Dead Floor Live Snow Total Accessories
1 - Trimmer - SPF 3.00"3.00"2.34"3359 4259 3125 10743 None
2 - Trimmer - SPF 3.00"3.00"1.61"1855 4259 117 6231 None
•Maximum allowable bracing intervals based on applied load.
Lateral Bracing Bracing Intervals Comments
Top Edge (Lu)9 6 0 o/c
Bottom Edge (Lu)9 6 0 o/c
Dead Floor Live Snow
Vertical Loads Location (Side)Tributary Width (0.90)(1.00)(1.15)Comments
0 - Self Weight (PLF)0 0 0 to 9 6 0 N/A 14.5 ----
1 - Uniform (PSF)0 0 0 to 9 6 0 11 11 0 15.0 40.0 -Residential - Living
Areas
2 - Uniform (PSF)0 0 0 to 9 6 0 1 0 0 115.0 --Wall - 9' Tall
3 - Uniform (PSF)0 0 0 to 9 6 0 7 0 0 10.0 60.0 -Exterior Deck Load
4 - Point (lb)0 5 8 N/A 1621 -3242 Linked from:
Dining, Support 1
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties
related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is
responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387
and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to
www.weyerhaeuser.com/woodproducts/document-library.
The product application, input design loads, dimensions and support information have been provided by G. Wallace
Weyerhaeuser Notes
All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal.
MEMBER REPORT PASSED
Lower Level, Rec Room - Patio
3 piece(s) 1 3/4" x 9 1/2" 2.0E Microllam® LVL
ForteWEB Software Operator Job Notes 10/26/2020 3:13:41 PM UTCGraig Wallace
Builders FirstSource
(612) 656-1626
graig.wallace@bldr.com
ForteWEB v3.0, Engine: V8.1.4.2, Data: V8.0.0.0
File Name: Sharper - 8194 198th
Sharper Homes
8194 198th St
Lakeville, MN
Page 19 / 29
Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern)
Member Reaction (lbs)2670 @ 0 1 8 3825 (3.00")Passed (70%)--1.0 D + 0.75 L + 0.75 S (All Spans)
Shear (lbs)1282 @ 1 0 4 2872 Passed (45%)1.15 1.0 D + 0.75 L + 0.75 S (All Spans)
Moment (Ft-lbs)2152 @ 1 6 0 3946 Passed (55%)1.15 1.0 D + 0.75 L + 0.75 S (All Spans)
Live Load Defl. (in)0.008 @ 1 8 9 0.093 Passed (L/999+)--1.0 D + 0.75 L + 0.75 S (All Spans)
Total Load Defl. (in)0.013 @ 1 8 10 0.162 Passed (L/999+)--1.0 D + 0.75 L + 0.75 S (All Spans)
System : Wall
Member Type : Header
Building Use : Residential
Building Code : IBC 2015
Design Methodology : ASD
•Deflection criteria: LL (L/420) and TL (L/240).
•Allowed moment does not reflect the adjustment for the beam stability factor.
•Applicable calculations are based on NDS.
Bearing Length Loads to Supports (lbs)
Supports Total Available Required Dead Floor Live Snow Total Accessories
1 - Trimmer - SPF 3.00"3.00"2.09"1163 694 1315 3172 None
2 - Trimmer - SPF 3.00"3.00"1.50"818 694 600 2112 None
•Maximum allowable bracing intervals based on applied load.
Lateral Bracing Bracing Intervals Comments
Top Edge (Lu)3 6 0 o/c
Bottom Edge (Lu)3 6 0 o/c
Dead Floor Live Snow
Vertical Loads Location (Side)Tributary Width (0.90)(1.00)(1.15)Comments
0 - Self Weight (PLF)0 0 0 to 3 6 0 N/A 7.0 ----
1 - Uniform (PSF)0 0 0 to 3 6 0 9 11 0 15.0 40.0 -Residential - Living
Areas
2 - Uniform (PSF)0 0 0 to 3 6 0 1 0 0 150.0 --Wall - 11' Tall
3 - Uniform (PSF)0 0 0 to 1 6 0 17 6 0 17.0 -35.0 MN Snow - SOUTH
4 - Point (lb)1 6 0 N/A 465 -996 Linked from: Great
Room, Support 1
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties
related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is
responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387
and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to
www.weyerhaeuser.com/woodproducts/document-library.
The product application, input design loads, dimensions and support information have been provided by G. Wallace
Weyerhaeuser Notes
All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal.
MEMBER REPORT PASSED
Lower Level, Rec Room - Left/Right
2 piece(s) 2 x 10 Spruce-Pine-Fir No. 1 / No. 2
ForteWEB Software Operator Job Notes 10/26/2020 3:13:41 PM UTCGraig Wallace
Builders FirstSource
(612) 656-1626
graig.wallace@bldr.com
ForteWEB v3.0, Engine: V8.1.4.2, Data: V8.0.0.0
File Name: Sharper - 8194 198th
Sharper Homes
8194 198th St
Lakeville, MN
Page 20 / 29
Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern)
Member Reaction (lbs)1229 @ 0 1 8 3825 (3.00")Passed (32%)--1.0 D + 1.0 L (All Spans)
Shear (lbs)512 @ 1 0 4 2498 Passed (21%)1.00 1.0 D + 1.0 L (All Spans)
Moment (Ft-lbs)927 @ 1 9 0 3431 Passed (27%)1.00 1.0 D + 1.0 L (All Spans)
Live Load Defl. (in)0.004 @ 1 9 0 0.093 Passed (L/999+)--1.0 D + 1.0 L (All Spans)
Total Load Defl. (in)0.006 @ 1 9 0 0.162 Passed (L/999+)--1.0 D + 1.0 L (All Spans)
System : Wall
Member Type : Header
Building Use : Residential
Building Code : IBC 2015
Design Methodology : ASD
•Deflection criteria: LL (L/420) and TL (L/240).
•Allowed moment does not reflect the adjustment for the beam stability factor.
•Applicable calculations are based on NDS.
Bearing Length Loads to Supports (lbs)
Supports Total Available Required Dead Floor Live Total Accessories
1 - Trimmer - SPF 3.00"3.00"1.50"535 694 1229 None
2 - Trimmer - SPF 3.00"3.00"1.50"535 694 1229 None
•Maximum allowable bracing intervals based on applied load.
Lateral Bracing Bracing Intervals Comments
Top Edge (Lu)3 6 0 o/c
Bottom Edge (Lu)3 6 0 o/c
Dead Floor Live
Vertical Loads Location (Side)Tributary Width (0.90)(1.00)Comments
0 - Self Weight (PLF)0 0 0 to 3 6 0 N/A 7.0 --
1 - Uniform (PSF)0 0 0 to 3 6 0 9 11 0 15.0 40.0 Residential - Living
Areas
2 - Uniform (PSF)0 0 0 to 3 6 0 1 0 0 150.0 -Wall - 11' Tall
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties
related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is
responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387
and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to
www.weyerhaeuser.com/woodproducts/document-library.
The product application, input design loads, dimensions and support information have been provided by G. Wallace
Weyerhaeuser Notes
All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal.
MEMBER REPORT PASSED
Lower Level, Rec Room - Center
2 piece(s) 2 x 10 Spruce-Pine-Fir No. 1 / No. 2
ForteWEB Software Operator Job Notes 10/26/2020 3:13:41 PM UTCGraig Wallace
Builders FirstSource
(612) 656-1626
graig.wallace@bldr.com
ForteWEB v3.0, Engine: V8.1.4.2, Data: V8.0.0.0
File Name: Sharper - 8194 198th
Sharper Homes
8194 198th St
Lakeville, MN
Page 21 / 29
Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern)
Member Reaction (lbs)8459 @ 8 4 8 11419 (3.00")Passed (74%)--1.0 D + 0.75 L + 0.75 S (All Spans)
Shear (lbs)2522 @ 1 0 8 10308 Passed (24%)1.00 1.0 D + 1.0 L (All Spans)
Moment (Ft-lbs)6687 @ 4 3 0 15633 Passed (43%)1.00 1.0 D + 1.0 L (All Spans)
Live Load Defl. (in)0.098 @ 4 3 0 0.236 Passed (L/999+)--1.0 D + 1.0 L (All Spans)
Total Load Defl. (in)0.161 @ 4 3 0 0.412 Passed (L/616)--1.0 D + 1.0 L (All Spans)
System : Wall
Member Type : Header
Building Use : Residential
Building Code : IBC 2015
Design Methodology : ASD
•Deflection criteria: LL (L/420) and TL (L/240).
•Allowed moment does not reflect the adjustment for the beam stability factor.
Bearing Length Loads to Supports (lbs)
Supports Total Available Required Dead Floor Live Snow Total Accessories
1 - Trimmer - SPF 3.00"3.00"2.02"3304 2026 3799 9129 None
2 - Trimmer - SPF 3.00"3.00"2.22"3714 2026 4301 10041 None
•Maximum allowable bracing intervals based on applied load.
Lateral Bracing Bracing Intervals Comments
Top Edge (Lu)8 6 0 o/c
Bottom Edge (Lu)8 6 0 o/c
Dead Floor Live Snow
Vertical Loads Location (Side)Tributary Width (0.90)(1.00)(1.15)Comments
0 - Self Weight (PLF)0 0 0 to 8 6 0 N/A 15.6 ----
1 - Uniform (PSF)0 0 0 to 8 6 0 11 11 0 15.0 40.0 -Residential - Living
Areas
2 - Uniform (PLF)0 0 0 to 8 6 0 N/A 115.0 --Wall
3 - Point (lb)8 4 8 N/A 2399 -4301 Linked from:
Master, Support 1
4 - Point (lb)0 1 8 N/A 1989 -3799 Linked from:
Master, Support 2
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties
related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is
responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387
and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to
www.weyerhaeuser.com/woodproducts/document-library.
The product application, input design loads, dimensions and support information have been provided by G. Wallace
Weyerhaeuser Notes
All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal.
MEMBER REPORT PASSED
Lower Level, Family Room - Rear
3 piece(s) 1 3/4" x 9 1/2" 1.55E TimberStrand® LSL
ForteWEB Software Operator Job Notes 10/26/2020 3:13:41 PM UTCGraig Wallace
Builders FirstSource
(612) 656-1626
graig.wallace@bldr.com
ForteWEB v3.0, Engine: V8.1.4.2, Data: V8.0.0.0
File Name: Sharper - 8194 198th
Sharper Homes
8194 198th St
Lakeville, MN
Page 22 / 29
Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern)
Member Reaction (lbs)983 @ 0 1 8 3825 (3.00")Passed (26%)--1.0 D + 1.0 S (All Spans)
Shear (lbs)618 @ 1 0 4 2872 Passed (22%)1.15 1.0 D + 1.0 S (All Spans)
Moment (Ft-lbs)1231 @ 2 9 0 3946 Passed (31%)1.15 1.0 D + 1.0 S (All Spans)
Live Load Defl. (in)0.010 @ 2 9 0 0.150 Passed (L/999+)--1.0 D + 1.0 S (All Spans)
Total Load Defl. (in)0.022 @ 2 9 0 0.262 Passed (L/999+)--1.0 D + 1.0 S (All Spans)
System : Wall
Member Type : Header
Building Use : Residential
Building Code : IBC 2015
Design Methodology : ASD
•Deflection criteria: LL (L/420) and TL (L/240).
•Allowed moment does not reflect the adjustment for the beam stability factor.
•Applicable calculations are based on NDS.
Bearing Length Loads to Supports (lbs)
Supports Total Available Required Dead Floor Live Snow Total Accessories
1 - Trimmer - SPF 3.00"3.00"1.50"549 9 433 991 None
2 - Trimmer - SPF 3.00"3.00"1.50"549 9 433 991 None
•Maximum allowable bracing intervals based on applied load.
Lateral Bracing Bracing Intervals Comments
Top Edge (Lu)5 6 0 o/c
Bottom Edge (Lu)5 6 0 o/c
Dead Floor Live Snow
Vertical Loads Location (Side)Tributary Width (0.90)(1.00)(1.15)Comments
0 - Self Weight (PLF)0 0 0 to 5 6 0 N/A 7.0 ----
1 - Uniform (PSF)0 0 0 to 5 6 0 0 0 0 15.0 40.0 -Residential - Living
Areas
2 - Uniform (PLF)0 0 0 to 5 6 0 N/A 115.0 --Wall
3 - Uniform (PSF)0 0 0 to 5 6 0 4 6 0 17.0 -35.0 MN Snow - SOUTH
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties
related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is
responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387
and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to
www.weyerhaeuser.com/woodproducts/document-library.
The product application, input design loads, dimensions and support information have been provided by G. Wallace
Weyerhaeuser Notes
All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal.
MEMBER REPORT PASSED
Lower Level, Storage
2 piece(s) 2 x 10 Spruce-Pine-Fir No. 1 / No. 2
ForteWEB Software Operator Job Notes 10/26/2020 3:13:41 PM UTCGraig Wallace
Builders FirstSource
(612) 656-1626
graig.wallace@bldr.com
ForteWEB v3.0, Engine: V8.1.4.2, Data: V8.0.0.0
File Name: Sharper - 8194 198th
Sharper Homes
8194 198th St
Lakeville, MN
Page 23 / 29
Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern)
Member Reaction (lbs)2030 @ 0 1 8 3825 (3.00")Passed (53%)--1.0 D + 1.0 L (All Spans)
Shear (lbs)899 @ 1 0 4 2498 Passed (36%)1.00 1.0 D + 1.0 L (All Spans)
Moment (Ft-lbs)1615 @ 1 10 0 3431 Passed (47%)1.00 1.0 D + 1.0 L (All Spans)
Live Load Defl. (in)0.009 @ 1 10 0 0.098 Passed (L/999+)--1.0 D + 1.0 L (All Spans)
Total Load Defl. (in)0.012 @ 1 10 0 0.171 Passed (L/999+)--1.0 D + 1.0 L (All Spans)
System : Wall
Member Type : Header
Building Use : Residential
Building Code : IBC 2015
Design Methodology : ASD
•Deflection criteria: LL (L/420) and TL (L/240).
•Allowed moment does not reflect the adjustment for the beam stability factor.
•Applicable calculations are based on NDS.
Bearing Length Loads to Supports (lbs)
Supports Total Available Required Dead Floor Live Total Accessories
1 - Trimmer - SPF 3.00"3.00"1.59"563 1467 2030 None
2 - Trimmer - SPF 3.00"3.00"1.59"563 1467 2030 None
•Maximum allowable bracing intervals based on applied load.
Lateral Bracing Bracing Intervals Comments
Top Edge (Lu)3 8 0 o/c
Bottom Edge (Lu)3 8 0 o/c
Dead Floor Live
Vertical Loads Location (Side)Tributary Width (0.90)(1.00)Comments
0 - Self Weight (PLF)0 0 0 to 3 8 0 N/A 7.0 --
1 - Uniform (PSF)0 0 0 to 3 8 0 20 0 0 15.0 40.0 Residential - Living
Areas
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties
related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is
responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387
and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to
www.weyerhaeuser.com/woodproducts/document-library.
The product application, input design loads, dimensions and support information have been provided by G. Wallace
Weyerhaeuser Notes
All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal.
MEMBER REPORT PASSED
Lower Level, Storage 3/0
2 piece(s) 2 x 10 Spruce-Pine-Fir No. 1 / No. 2
ForteWEB Software Operator Job Notes 10/26/2020 3:13:41 PM UTCGraig Wallace
Builders FirstSource
(612) 656-1626
graig.wallace@bldr.com
ForteWEB v3.0, Engine: V8.1.4.2, Data: V8.0.0.0
File Name: Sharper - 8194 198th
Sharper Homes
8194 198th St
Lakeville, MN
Page 24 / 29
Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern)
Member Reaction (lbs)3812 @ 4 1 12 4463 (3.50")Passed (85%)--1.0 D + 1.0 L (All Spans)
Shear (lbs)1309 @ 5 0 12 2498 Passed (52%)1.00 1.0 D + 1.0 L (All Spans)
Moment (Ft-lbs)-1453 @ 4 1 12 3431 Passed (42%)1.00 1.0 D + 1.0 L (All Spans)
Live Load Defl. (in)0.008 @ 6 1 8 0.109 Passed (L/999+)--1.0 D + 1.0 L (Alt Spans)
Total Load Defl. (in)0.010 @ 6 1 12 0.191 Passed (L/999+)--1.0 D + 1.0 L (Alt Spans)
System : Floor
Member Type : Flush Beam
Building Use : Residential
Building Code : IBC 2015
Design Methodology : ASD
•Deflection criteria: LL (L/420) and TL (L/240).
•Allowed moment does not reflect the adjustment for the beam stability factor.
•Applicable calculations are based on NDS.
• Blocking Panels are assumed to carry no loads applied directly above them and the full load is applied to the member being designed.
Bearing Length Loads to Supports (lbs)
Supports Total Available Required Dead Floor Live Total Accessories
1 - Stud wall - SPF 5.50"5.50"1.50"310 954/-161 1264/-
161 Blocking
2 - Stud wall - SPF 3.50"3.50"2.99"1064 2748 3812 None
3 - Stud wall - SPF 3.50"3.50"1.50"434 1241/-114 1675/-
114 Blocking
•Maximum allowable bracing intervals based on applied load.
Lateral Bracing Bracing Intervals Comments
Top Edge (Lu)8 2 0 o/c
Bottom Edge (Lu)8 2 0 o/c
Dead Floor Live
Vertical Loads Location (Side)Tributary Width (0.90)(1.00)Comments
0 - Self Weight (PLF)0 0 0 to 8 1 8 N/A 7.0 --
1 - Uniform (PSF)0 0 0 to 8 1 8 (Top)11 11 0 15.0 40.0 Residential - Living
Areas
2 - Uniform (PSF)4 1 8 to 8 1 8 (Top)5 0 0 15.0 40.0 Stairway
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties
related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is
responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387
and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to
www.weyerhaeuser.com/woodproducts/document-library.
The product application, input design loads, dimensions and support information have been provided by G. Wallace
Weyerhaeuser Notes
All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal.
MEMBER REPORT PASSED
Lower Level, Stairway Flush Beam
2 piece(s) 2 x 10 Spruce-Pine-Fir No. 1 / No. 2
ForteWEB Software Operator Job Notes 10/26/2020 3:13:41 PM UTCGraig Wallace
Builders FirstSource
(612) 656-1626
graig.wallace@bldr.com
ForteWEB v3.0, Engine: V8.1.4.2, Data: V8.0.0.0
File Name: Sharper - 8194 198th
Sharper Homes
8194 198th St
Lakeville, MN
Page 25 / 29
Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern)
Member Reaction (lbs)6350 @ 10 1 0 6978 (2.75")Passed (91%)--1.0 D + 1.0 L (All Spans)
Shear (lbs)5139 @ 1 2 14 7897 Passed (65%)1.00 1.0 D + 1.0 L (All Spans)
Moment (Ft-lbs)16350 @ 5 0 9 17848 Passed (92%)1.00 1.0 D + 1.0 L (All Spans)
Live Load Defl. (in)0.228 @ 5 1 1 0.285 Passed (L/523)--1.0 D + 1.0 L (All Spans)
Total Load Defl. (in)0.343 @ 5 1 1 0.498 Passed (L/348)--1.0 D + 1.0 L (All Spans)
System : Floor
Member Type : Drop Beam
Building Use : Residential
Building Code : IBC 2015
Design Methodology : ASD
•Deflection criteria: LL (L/420) and TL (L/240).
•Allowed moment does not reflect the adjustment for the beam stability factor.
Bearing Length Loads to Supports (lbs)
Supports Total Available Required Dead Floor Live Total Accessories
1 - Trimmer - SPF 3.00"3.00"2.68"2274 4538 6812 None
2 - Trimmer - SPF 2.75"2.75"2.50"2146 4204 6350 None
•Maximum allowable bracing intervals based on applied load.
Lateral Bracing Bracing Intervals Comments
Top Edge (Lu)5 6 0 o/c
Bottom Edge (Lu)10 2 0 o/c
Dead Floor Live
Vertical Loads Location (Side)Tributary Width (0.90)(1.00)Comments
0 - Self Weight (PLF)0 0 0 to 10 2 4 N/A 12.1 --
1 - Uniform (PSF)0 0 0 to 6 9 0 (Top)22 6 0 15.0 40.0 Residential - Living
Areas
2 - Uniform (PSF)6 9 0 to 10 1 0 (Top)20 0 0 15.0 40.0 Residential - Living
Areas
3 - Uniform (PLF)0 0 0 to 10 2 4 (Top)N/A 100.0 -Interior Wall - 9'
Tall
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties
related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is
responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387
and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to
www.weyerhaeuser.com/woodproducts/document-library.
The product application, input design loads, dimensions and support information have been provided by G. Wallace
Weyerhaeuser Notes
All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal.
MEMBER REPORT PASSED
Lower Level, Floor Drop Beam
2 piece(s) 1 3/4" x 11 7/8" 2.0E Microllam® LVL
ForteWEB Software Operator Job Notes 10/26/2020 3:13:41 PM UTCGraig Wallace
Builders FirstSource
(612) 656-1626
graig.wallace@bldr.com
ForteWEB v3.0, Engine: V8.1.4.2, Data: V8.0.0.0
File Name: Sharper - 8194 198th
Sharper Homes
8194 198th St
Lakeville, MN
Page 26 / 29
Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern)
Member Reaction (lbs)1793 @ 0 1 8 3825 (3.00")Passed (47%)--1.0 D + 1.0 L (All Spans)
Shear (lbs)420 @ 1 0 4 2498 Passed (17%)1.00 1.0 D + 1.0 L (All Spans)
Moment (Ft-lbs)982 @ 1 4 0 3431 Passed (29%)1.00 1.0 D + 1.0 L (All Spans)
Live Load Defl. (in)0.002 @ 1 4 0 0.069 Passed (L/999+)--1.0 D + 1.0 L (All Spans)
Total Load Defl. (in)0.004 @ 1 4 0 0.121 Passed (L/999+)--1.0 D + 1.0 L (All Spans)
System : Wall
Member Type : Header
Building Use : Residential
Building Code : IBC 2015
Design Methodology : ASD
•Deflection criteria: LL (L/420) and TL (L/240).
•Allowed moment does not reflect the adjustment for the beam stability factor.
•Applicable calculations are based on NDS.
Bearing Length Loads to Supports (lbs)
Supports Total Available Required Dead Floor Live Total Accessories
1 - Trimmer - SPF 3.00"3.00"1.50"593 1200 1793 None
2 - Trimmer - SPF 3.00"3.00"1.50"593 1200 1793 None
•Maximum allowable bracing intervals based on applied load.
Lateral Bracing Bracing Intervals Comments
Top Edge (Lu)2 8 0 o/c
Bottom Edge (Lu)2 8 0 o/c
Dead Floor Live
Vertical Loads Location (Side)Tributary Width (0.90)(1.00)Comments
0 - Self Weight (PLF)0 0 0 to 2 8 0 N/A 7.0 --
1 - Uniform (PSF)0 0 0 to 2 8 0 22 6 0 15.0 40.0 Residential - Living
Areas
2 - Uniform (PLF)0 0 0 to 2 8 0 N/A 100.0 -Interior Wall - 9'
Tall
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties
related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is
responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387
and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to
www.weyerhaeuser.com/woodproducts/document-library.
The product application, input design loads, dimensions and support information have been provided by G. Wallace
Weyerhaeuser Notes
All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal.
MEMBER REPORT PASSED
Lower Level, Closet 2/0
2 piece(s) 2 x 10 Spruce-Pine-Fir No. 1 / No. 2
ForteWEB Software Operator Job Notes 10/26/2020 3:13:41 PM UTCGraig Wallace
Builders FirstSource
(612) 656-1626
graig.wallace@bldr.com
ForteWEB v3.0, Engine: V8.1.4.2, Data: V8.0.0.0
File Name: Sharper - 8194 198th
Sharper Homes
8194 198th St
Lakeville, MN
Page 27 / 29
Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern)
Member Reaction (lbs)2465 @ 0 1 8 3825 (3.00")Passed (64%)--1.0 D + 1.0 L (All Spans)
Shear (lbs)1092 @ 1 0 4 2498 Passed (44%)1.00 1.0 D + 1.0 L (All Spans)
Moment (Ft-lbs)1962 @ 1 10 0 3431 Passed (57%)1.00 1.0 D + 1.0 L (All Spans)
Live Load Defl. (in)0.010 @ 1 10 0 0.098 Passed (L/999+)--1.0 D + 1.0 L (All Spans)
Total Load Defl. (in)0.015 @ 1 10 0 0.171 Passed (L/999+)--1.0 D + 1.0 L (All Spans)
System : Wall
Member Type : Header
Building Use : Residential
Building Code : IBC 2015
Design Methodology : ASD
•Deflection criteria: LL (L/420) and TL (L/240).
•Allowed moment does not reflect the adjustment for the beam stability factor.
•Applicable calculations are based on NDS.
Bearing Length Loads to Supports (lbs)
Supports Total Available Required Dead Floor Live Total Accessories
1 - Trimmer - SPF 3.00"3.00"1.93"815 1650 2465 None
2 - Trimmer - SPF 3.00"3.00"1.93"815 1650 2465 None
•Maximum allowable bracing intervals based on applied load.
Lateral Bracing Bracing Intervals Comments
Top Edge (Lu)3 8 0 o/c
Bottom Edge (Lu)3 8 0 o/c
Dead Floor Live
Vertical Loads Location (Side)Tributary Width (0.90)(1.00)Comments
0 - Self Weight (PLF)0 0 0 to 3 8 0 N/A 7.0 --
1 - Uniform (PSF)0 0 0 to 3 8 0 22 6 0 15.0 40.0 Residential - Living
Areas
2 - Uniform (PLF)0 0 0 to 3 8 0 N/A 100.0 -Interior Wall - 9'
Tall
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties
related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is
responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387
and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to
www.weyerhaeuser.com/woodproducts/document-library.
The product application, input design loads, dimensions and support information have been provided by G. Wallace
Weyerhaeuser Notes
All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal.
MEMBER REPORT PASSED
Lower Level, Mech 3/0
2 piece(s) 2 x 10 Spruce-Pine-Fir No. 1 / No. 2
ForteWEB Software Operator Job Notes 10/26/2020 3:13:41 PM UTCGraig Wallace
Builders FirstSource
(612) 656-1626
graig.wallace@bldr.com
ForteWEB v3.0, Engine: V8.1.4.2, Data: V8.0.0.0
File Name: Sharper - 8194 198th
Sharper Homes
8194 198th St
Lakeville, MN
Page 28 / 29
Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern)
Member Reaction (lbs)2432 @ 3 6 8 3825 (3.00")Passed (64%)--1.0 D + 1.0 L (All Spans)
Shear (lbs)1068 @ 1 0 4 2498 Passed (43%)1.00 1.0 D + 1.0 L (All Spans)
Moment (Ft-lbs)1905 @ 1 10 5 3431 Passed (56%)1.00 1.0 D + 1.0 L (All Spans)
Live Load Defl. (in)0.010 @ 1 10 3 0.098 Passed (L/999+)--1.0 D + 1.0 L (All Spans)
Total Load Defl. (in)0.014 @ 1 10 3 0.171 Passed (L/999+)--1.0 D + 1.0 L (All Spans)
System : Wall
Member Type : Header
Building Use : Residential
Building Code : IBC 2015
Design Methodology : ASD
•Deflection criteria: LL (L/420) and TL (L/240).
•Allowed moment does not reflect the adjustment for the beam stability factor.
•Applicable calculations are based on NDS.
Bearing Length Loads to Supports (lbs)
Supports Total Available Required Dead Floor Live Total Accessories
1 - Trimmer - SPF 3.00"3.00"1.82"775 1543 2318 None
2 - Trimmer - SPF 3.00"3.00"1.91"806 1626 2432 None
•Maximum allowable bracing intervals based on applied load.
Lateral Bracing Bracing Intervals Comments
Top Edge (Lu)3 8 0 o/c
Bottom Edge (Lu)3 8 0 o/c
Dead Floor Live
Vertical Loads Location (Side)Tributary Width (0.90)(1.00)Comments
0 - Self Weight (PLF)0 0 0 to 3 8 0 N/A 7.0 --
1 - Uniform (PSF)0 0 0 to 1 6 0 20 3 12 15.0 40.0 Residential - Living
Areas
2 - Uniform (PLF)0 0 0 to 3 8 0 N/A 100.0 -Interior Wall - 9'
Tall
3 - Uniform (PSF)1 6 0 to 3 8 0 22 6 0 15.0 40.0 Residential - Living
Areas
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties
related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is
responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387
and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to
www.weyerhaeuser.com/woodproducts/document-library.
The product application, input design loads, dimensions and support information have been provided by G. Wallace
Weyerhaeuser Notes
All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal.
MEMBER REPORT PASSED
Lower Level, Bath 3/0
2 piece(s) 2 x 10 Spruce-Pine-Fir No. 1 / No. 2
ForteWEB Software Operator Job Notes 10/26/2020 3:13:41 PM UTCGraig Wallace
Builders FirstSource
(612) 656-1626
graig.wallace@bldr.com
ForteWEB v3.0, Engine: V8.1.4.2, Data: V8.0.0.0
File Name: Sharper - 8194 198th
Sharper Homes
8194 198th St
Lakeville, MN
Page 29 / 29
Tab 0
EMS Heat Loss/Heat Gain Calculation
Company: WestAIR Heating & Cooling Customer: Sharper Homes
Preparer: Maria Haus Address:
8194-198th Street, Lakeville
MN 55044Phone:763-498-8071
Phone: 763-783-1000
Date: 10/22/2020
This HVAC load calculation has been performed using sound engineering principles as prescribed by Manual J
seventh and eighth abridged editions and ASHRAE Fundamentals. Duct sizing has been performed as prescribed by
Manual D.
1. Design Conditions
Indoor Outdoor Temp. Diff.Front of home is facing:
Winter 70 -12 82 South
Summer 75 89 14
2. How would you describe the summer humidity in your area? Moderately Humid 40
3. How tight is the house? Average-over 1500 Sq. Ft.
Winter air change / hr: 0.7 Summer air change / hr: 0.35
4. Fireplace evaluation : Number: 2 Tightness: Average 40
5. Number of occupants: 5
6. Overhang characteristics (optional)
East West S/SE/SW
Distance of overhang from
top of window (Ft.)
Length of overhang
Tab 1
7. Solar gain through glass
Use Manufacturer's Specs to determine HTM
Latitude:44 U-value .29 SHGC .33
Facing Total area - Sq.Ft.Type of glass HTM Linear ft.Unshaded Shaded BTUH
N/Shaded 156 -- Select --10 Below OH 156
NE/NW -- Select --24 0 0
South 58 -- Select --18 58 0 1044
SE/SW -- Select --30 0 0 0
East 9 -- Select --34 9 0 306
West 14 -- Select --34 14 0 476
Skylight -- Select --0
Total North and Shaded 156 1560
Total Solar Gain 3386
Adjust for tinted or reflective window coating?No 1 3386
8. Ducts/Pipes
Location:All duct work in conditioned area
Attic Temp.Insulation Leakage Area
-- Select ---- Select ---- Select --
Duct gain:0 Duct loss:0
Tab 2
9. Load Calculation
Elements of Load Insulation / R-value Area/lin.ft.U-value Heat Loss Heat Gain
Gross Wall 2060 Glass solar gain 3386
Glass 1 -- Select --237 5636
Glass 2 -- Select --0
Skylight -- Select --0 0
Doors Insulated or Storm 42 0.4 1378 235
Net walls R-22 1781 0.045 6572 1122
Ceilings R-45 2102 0.022 3792 2081
Floors -- Select --0 0
Open floors -- Select --0 0
Slab floors -- Select --0 0
Volume of your building or zone (cu. Ft.)21020 25728 1888
People 1500
Appliances 6000
Sub Total 43105 16213
Duct Loss/Gain 0 0
Sensible Load 43105 16213
Latent Load 4485
TOTAL BTUH 43105 20698
Summary
BTUH Tons
Total heating load 43105
Total cooling load 20698 1.7
Tab 3
Basement Calculation
Elements of Load Insulation / R-value Area/lin.ft.U-value Heat Loss Heat Gain
Walls - above grade 824
Glass -- Select --148 0
North Double 136 24 3264
South -- Select --0
East Double 12 75 900
West -- Select --0
Doors -- Select --0 0
Net walls (above)R-19 676 0.024 1330 227
Walls (below grade)R-15 824 0.06 4054 0
Ceilings -- Select --0 0
Floors 2102 0.024 4137 0
Infiltration (Cu.Ft.)16816 6320 1079
Number of people 300 0
Appliances - Enter total BTUH ->0
Sensible Load:15841 5470
Latent Load:1906
TOTAL BTUH:15841 7376
Total whole house load including basement:58947 28074
Per R401.3 Certificat. A building certificate shall be Date Certificate Posted
posted on or in the distribution panel
Mailing Address of the Dwelling or Dwelling Unit City
8194-198th Street Lakeville, MN
Name of Residential Contractor MN License Number
Sharper Homes Inc BC-356604
X Passive (No Fan)
Active (With fan and monometer
or other system monitoring
device)
Location (or future location) of Fan:
Other Please Describe Here
X
R-10 XX
R-10 XX
R-21 X
X
R-21 X
R-49 X
X
R-38 X
X
X Not applicable, all ducts located in conditioned space
X Not required per mech. code
Passive
Powered
Interlocked with exhaust device.
Describe:
Input in
BTUS:84,000
Capacity in
Gallons:
Other, describe:
AFUE or
HSPF%95%
Cfm's
" round duct OR
" metal duct
Describe any additional or combined heating or cooling systems if installed:
(e.g. two furnaces or air source heat pump with gas back-up furnace):Not required per mech. code
X Passive
X Low: Other, describe:
Low:
Location of fan(s), describe: Cfm's
" round duct OR
6 " metal duct
Describe other insulated areas
Building envelope air tightness:
Location of duct or system:
MECHANICAL SYSTEMS
Average U-Factor (excludes skylights and & door ) U:
Solar Heat Gain Coefficient (SHGC):
Heating System
0.33
Appliances Cooling System
Domestic Water
Heater
N/ADuct system air tightness:
Location of duct or system:High:
MECHANICAL VENTILATION SYSTEM
High:
Select Type
Rheem
Rating or Size
58,947
Heating Gain
Rheem
R95PA0851521
Heat Recover Ventilator (HRV) Capacity in cfms:
Energy Recover Ventilator (ERV) Capacity in cfms:
13SEER
/EER
Cooling Load
Total ventilation (intermittent + continuous) rate in cfms:
Balanced Ventilation capacity in cfms:
165
83 Capacity continuous ventilation rate in cfms:
Hallway - Source point
43,750
Manufacturer
Heating Loss
28,074
Efficiency
50
Model
Rheem
Residential Load
Calculation
42PV50F RA1342AJ1NA
Inside to outside
83 165
Combustion Air Select a Type
Output in
Tons:3.5
Make-up Air Select a Type
0.29
Heating or Cooling Ducts Outside Conditioned Spaces Windows & Doors
R-value
Truss Joist (2nd Floor+)
Ceiling, vaulted
Bay Windows or cantilevered areas
2.6 max air leakFiberglass, BlownFiberglass, BattsRigid, IsocynurateMineral FiberboardRigid, Extruded PolystyreneElectric
Ceiling, flat
Floors over unconditioned area (garage)
Below Entire Slab
Wall
Perimeter of Slab on Grade
Truss Joist (1st Floor)
Fuel Type Natural Natural Gas Foam, Closed CellNon or Not ApplicableFoam Open CellNew Construction Energy Code Compliance Certificate
Foundation Wall
THERMAL ENVELOPE
Insulation Location
2.6 max air leak
RADON CONTROL SYSTEM
Type: Check All That Apply
Total R-Value of all Types of Insulation000000Builders Associaton of Minnesota version 101014
11/17/2020 X
KP