HomeMy WebLinkAboutLA186684 - 17999 Grantham Lane Permit PackRESIDENTIAL BUILDING
PERMIT APPLICATION
CITY OF LAKEVILLE
BUILDING INSPECTIONS DEPARTMENT
20195 HOLYOKE AVENUE
LAKEVILLE, MN 55044
952-985-4440
Office Use Only
__________________
Permit Number
___________________
Received By
___________________
Date Received
___________________
Fee Total
SITE ADDRESS:
MAILING ADDRESS: CITY: STATE: ZIP:
JOB DESCRIPTION:__________________________________ MASTER PLAN: (Number or Address)____________________
LIST OTHER STRUCTURES ON PROPERTY:_______________________________________________________________
ESTIMATED VALUATION: PROPOSED START DATE: END DATE:
(New Residential Only): LEGAL DESCRIPTION: LOT: _____ BLOCK: _____ SUBDIVISION:
APPLICANT IS: RESIDENT OWNER CONTRACTOR EMAIL
NEW MODEL HOME: YES NO (IF YES – ADMINISTRATIVE PERMIT REQUIRED)
PLEASE FILL OUT THE FOLLOWING COMPLETELY (All Contractor information must be as listed on State License)
RESIDENT OWNER
NAME:_______________________________________________________________________________
HOME PHONE #:_____________________________ CELL PHONE:___________________________
GENERAL CONTRACTOR
Homeowner
Contractor
CONTRACTOR:_______________________________________________________________________
LICENSE #:BC______________ LEAD CERTIFICATE#_______________ (PRE 1978 STRUCTURE)
OFFICE PHONE #:_____________________________ CELL PHONE:___________________________
ADDRESS:____________________________ CITY:________________ ST:______ ZIP:____________
PLUMBING WORK
Homeowner
Contractor
CONTRACTOR:__________________________________________LICENSE #: PM______________
OFFICE PHONE #:_____________________________ CELL PHONE:___________________________
ADDRESS:____________________________ CITY:________________ ST:______ ZIP:____________
MECHANICAL WORK
Homeowner
Contractor
CONTRACTOR:________________________________________ _______________________________
OFFICE PHONE #:_____________________________ CELL PHONE:___________________________
ADDRESS:____________________________ CITY:________________ ST:______ ZIP:____________
BOND #:_______________________________________ EXPIRATION DATE____________________
SEWER/WATER CONTRACTOR
New Construction Only
NAME:________________________________________________ ______________________________
HOME PHONE _____________________________ CELL PHONE:______________________________
BOND #:_______________________________________ EXPIRATION DATE____________________
INTEREST EARNINGS ON THE ESCROW ACCOUNTS, IF ANY, ARE RETAINED BY THE CITY TO OFFSET THE
ADMINISTRATIVE COSTS ASSOCIATED WITH PROCESSING THE ESCROW APPLICATION AND REFUND. I HEREBY
APPLY FOR A BUILDING PERMIT AND I ACKNOWLEDGE THAT THE INFORMATION ABOVE IS COMPLETE AND
ACCURATE; THAT THE WORK WILL BE IN CONFORMANCE WITH THE ORDINANCES AND CODES OF THE CITY AND
WITH THE STATE BUILDING CODE, THAT I UNDERSTAND THIS IS NOT A PERMIT AND WORK IS NOT TO START
WITHOUT A PERMIT AND THAT THE WORK WILL BE IN ACCORDANCE WITH THE APPROVED PLAN.
NAME OF APPLICANT (Please Print)DATE
APPLICANT’S SIGNATURE:
www.lakevillemn.gov
RESIDENTIAL BUILDING PERMIT APPLICATION
PAGE 2
OFFICE USE ONLY
BUILDING PERMIT TYPE REQUIRED INSPECTIONS
SINGLE FAMILY DWELLING BUILDING
DUPLEX AS BUILT
TOWNHOUSE UNITS BUILDING FINAL
DETACHED TOWN HOUSE UNIT DECK FOOTING
CONDO FIREPLACE
ACESSORY BUILDING FOOTING
REROOF FOUNDATION
RESIDE FRAMING
PORCH FRAMING
GARAGES
INSULATION
RES ADDN/REPAIR/RMDL
DECK
PORCH
GARAGES LATH
LOWER LEVEL FINISH LOWER LEVEL FINAL
ADDITION OTHER
FOUNDATION ONLY PORCH FOOTING
MISCELLANEOUS POURED WALL
DEMO SEPTIC TANK REMOVAL
MOVED SITE
MECHANICAL
CITY BUILDING VALUATION: $AIR TEST
FINAL
BUILDING PERMIT FEES ROUGH-IN
$PERMIT FEE PLUMBING
$PLAN CHECK FINAL
$SURCHARGE ROUGH-IN
$METRO SAC METER SIZE
$CITY WATER HOOKUP UNIT PRESSURE REDUCING VALVE
$CITY SEWER HOOKUP UNIT SEWER/WATER
$LANDSCAPE ESCROW SEWER/WATER
$TREE ESCROW FINAL
$MISC ESCROW STREET DRAINTILE
$PLUMBING BUILDING INFORMATION
$MECHANICAL TYPE OF CONSTRUCTION
$SEWER WATER ZONING
$OTHER CODE EDITION
$TOTAL FIRE SUPPRESSION SYSTEM
OCCUPANCY GROUP
APPROVED BY:
BUILDING INSPECTOR: Date:
PLUMBING/MECHANICAL
INSPECTOR: Date:
COMMENTS:
20195 Holyoke Avenue, Lakeville, MN 55044
952-985-4400 952-985-4499 fax
www.lakevillemn.gov
Sewer & Water Tie Card
Address:________________________________________
Contractor:______________________________________
Permit Number:__________________________________
Final Date:________________
Street Drain-Tile:______
Size of Water Service: 1”
Comments: AIRTEST SANITARY OVER 20’/2 FITTINGS
THIS CARD MUST BE COMPLETED AND ON-SITE AT TIME
OF SEWER & WATER INSPECTION
19SCALE: 1/4" = 1'-0"FRONT ELEVATIONGENERAL NOTES:1. ALL DOOR AND WINDOW HEADERS TO BE S.P.F. #2 OR BETTER, SEE PLANS FOR SIZES.2. HOUSE TO BE BUILT PER CURRENT I.R.C. CODES.3. VERIFY GRADES AND ADJUST FOUNDATION/FOOTING STEPS AS NEEDED.4. SEE PLANS FOR CEILING HEIGHTS5. 4' HIGH POURED FDN. WALLS STD.6. FLOOR PLAN DIMENSIONS ARE TO FACE OF FRAMING AND FOUNDATION.7. ALL TRADES & SUPPLIERS TO REVIEW & VERIFY INFORMATION PERTINENT TO THEIR WORK AND NOTIFY CONST. OF ANYDISCREPANCIES PRIOR TO CONSTRUCTION.8. NOTED CABINET SIZES ARE +/- AND TO BE FIELD VERIFIED.9. TRADES TO VERIFY BASE AND TRIM SIZE PRIOR TO CONSTRUCTION.10. ALL WALLS MORE THAN 10' H. TO BE S.P.F. #2 OR BETTER. 11. EXTERIOR ELEVATIONS ARE CONCEPTUAL ONLY:HOME SITE, FILL AND TOPOGRAPHY WILL DICTATEACTUAL GRADES AND MAY VARY FROM THOSE SHOWN ON THE PLAN.12. NOTE: SUBFLOOR JOINTS SHALL BESTAGGERED FROM FLOOR TRUSS ORJOIST JOINTSOFSHEET07-00-BUYERPROJECT #BUYER S/OBUYER S/OREVISIONS:STARTED:AGENT:XX10-27-20 PERMIT10-30-20 REV.11-6-20 REV.11-30-20 REV.12-5-20 REV.SEE ROOF PLAN FORROOF PITCHES ANDOVERHANGS25'-6"CONC. PORCH4" TRIM TYP.6:12T.O. 3048 SHALUM. SOFFIT& FASCIA30 YR. ARCH. ASPHALT SHINGLES2x OVER 6" TRIM14" LP COLUMN, TYP.
9'-1 1/8"T.O. SUBFLR.T.O. PLATE 1'-8 1/4"T.O. FDN.9'-1 1/8"@ GARAGET.O. PLATE 12121212STAT. (BLACKENED)1'-0"
6" TRIM12" CANT.10" TRIMMETAL CORNERSTYP.SADDLEC/LT.O. FDN.8'-11 1/2"@ DORMERT.O. PLATE8'-3 1/4"FP CHASE24"x60" FALSE6" TRIM & BATTENPER SPECS10" TRIMC/L2x OVER 6" TRIMGLS.GLS.GLS.GLS.LP BOARDSTONE TOTAL: 88 SQ. FT. (32.7%)TOTAL SQ. FT.: 269 SQ. FT.MATERIAL CALCULATIONS: FRONT ELEV.LP LAP SIDING TOTAL: 30 SQ. FT. (11.2%)LP B&B TOTAL: 108 SQ. FT. (40.1%)LP TRIM / PANEL: 43 SQ. FT. (16%)STONE TOTAL: 142 SQ. FT. (9.4%)TOTAL SQ. FT.: 1,900MATERIAL CALCULATIONS: ALL ELEV.LP LAP SIDING TOTAL: 1075 SQ. FT. (68.6%)LP B&B TOTAL: 167 SQ. FT. (11.1%)LP TRIM / PANEL: 123 SQ. FT. (7.9%)LP PANEL8" BOXED HEADERConcept Approval ONLYSubject to Field InspectionInspectorDate2020MN BldgCode11/30/2020dmathews
EXTERIOR ELEVATIONS ARE CONCEPTUAL ONLY:HOME SITE, FILL AND TOPOGRAPHY WILL DICTATEACTUAL GRADES AND MAY VARY FROM THOSE SHOWN ON THE PLAN.2907-00-BUYERPROJECT #BUYER S/OBUYER S/OREVISIONS:STARTED:AGENT:XX10-27-20 PERMIT10-30-20 REV.11-6-20 REV.11-30-20 REV.12-5-20 REV.OFSHEETSIDE ELEVATIONSIDE ELEVATIONSCALE: 1/8" = 1'-0"SCALE: 1/8" = 1'-0"REAR ELEVATIONSCALE: 1/8" = 1'-0"@ GARAGE9'-1 1/8"T.O. FDN.A/C UNIT12:12126126T.O. PLATESEE ROOF PLANFOR PITCHES ANDOVERHANGS8" TRIM8'-11 1/2"@ DORMERT.O. PLATE12:12LP CORNERS4" LP TRIM @ WDWS. & DOORS TYP.ROOF LINEBEYOND10" TRIMT.O. PLATE9'-1 1/8"T.O. SUBFLR.T.O. FDN.1'-8 1/4"12:12ALUM. SOFFIT& FASCIA12612612" CANT.FP VENTSEE ROOF PLANFOR PITCHES ANDOVERHANGSLP SIDING PER SPECSLP CORNERS4" LP TRIM @ WDWS. & DOORS TYP.12:1212:12T.O. PLATE9'-1 1/8"T.O. SUBFLR.T.O. FDN.1'-8 1/4"SEE ROOF PLANFOR PITCHES ANDOVERHANGSALUM. SOFFIT& FASCIA6:12LP SIDING PER SPECS12" CANT.10" TRIMLP CORNERS4" LP TRIM @ WDWS. & DOORS TYP.T.O. PLATE9'-1 1/8"T.O. SUBFLR.T.O. FDN.1'-8 1/4"10" TRIM
SCALE: 3/16" = 1'-0"FOUNDATION PLAN3907-00-BUYERPROJECT #BUYER S/OBUYER S/OREVISIONS:STARTED:AGENT:XX10-27-20 PERMIT10-30-20 REV.11-6-20 REV.11-30-20 REV.12-5-20 REV.OFSHEETA/C UNITw/ BRACKETFURNF.D.WHMECH. / STORAGEWS3068CONC.H.B.H.B.2" LEDGE TYP. TO PROVIDE ADD'L.SUPPORT FOR FILL FOR SLABTYP. FND @ HOUSE / GARAGE10" POURED CONC. W/ 4" LEDGE INSIDE20X8 CONC. FTG.2" FOAMSUMPH204" LEDGE2" FOAMTYP. FND @ STOOP10" POURED CONC. W/ 4" LEDGE INSIDE20X8 CONC. FTG.UNEXCAVATED2"NOTE: NO DRYWALL @ CLG.REQUIRED IN THIS AREA -FIRE BLOCK @ PERIMETEROF OPNG. (80 SQ. FT. MAX.)6"2"RADON VENT TOTERMINATE IN SUMP BASKET6"4"10"GARAGE/HOUSE COMMON WALL2x8 TREATED SILLOVERHANG FDN. 2''GARAGE SLAB2'' RIGID INSUL.MAIN FLRSEE FIRST FLOOR FORGARAGE DOOR SIZE FOR M.O.NOTE:4" LEDGE6"2"3 1/2'' CONC. FLOORTYP. FND @ HOUSE8" POURED CONC. (8'-4" H.)20X8 FTGREBAR PER CODETYP. FND @ BRG. WALL2x4 STUDS 16" O.C.16X8 FTGREBAR PER CODE4" CONC. CURB KITCHEN ISLAND ABV.FLR. TRUSS CO. OPT.18" FLR. TRUSSES
19.2" O.C. SPACING 2-2x10 (DR)RADON VENTFOUND. HELD IN 2"FOR INSULATIONNOTE:(TYP.)NOTE: EXTERIOR HOUSE AND GARAGE/HOUSECOMMON FDN. WALLS TO BE HELD 2'' IN. DIMENSIONS SHOWN ARE TO FACE OF 2''EXTERIOR RIGID INSULATION & FRAMING ABOVE TO BE 5000 PSI CONC.NOTE: ALL FOOTINGS 2'' MIN.2x8 TREATEDSILL-OVERHANGFDN. 1 1/2''8"2"TYP. SIDEWALL DETAILFOUND. HELD IN 2"FOR INSULATIONNOTE:(TYP.)2"2"8'-4" POURED FDN.FILL FOR SLABUP 17 R (10" T.,7-3/4" MAX. R.)40'-0"15'-0"12'-0"56'-0"
6'-0"50'-0"
56'-0"
1'-0"28'-0"27'-0"
14'-4"13'-8"9'-0 1/2"11'-6"5'-0"
7'-6"14'-6"
2'-6"40'-0"19'-0"21'-0"20'-0"13'-0"6'-0" & HOUSE/PORCH 10'-0"11'-0"10'-0"18" FLR. TRUSSES
19.2" O.C. SPACING3-9 1/2" LSL (DR)FOUND. HELD IN 2"FOR INSULATIONNOTE:(TYP.) SMOKECM / 12" CANT. ABV.2x6 BRG.2x6 BRG.18" FLR. TRUSSES
19.2" O.C. SPACING9'-4" H. FOUND. WALL@ FRONT OF HOMENOTE:9'-4" H. FOUND. WALL@ FRONT OF HOMENOTE:w/ TOP HUNG TRUSSESw/ TOP HUNG TRUSSES9'-4" H. FOUND. WALL@ FRONT OF HOMENOTE:w/ TOP HUNG TRUSSES11'-1 1/2"15'-10 1/4"11'-8 3/4"3'-2"1'-3"3'-0"7'-10"13'-0 1/4"3'-9"3'-10"7'-1 1/2"21'-3"11'-6"17'-3"9'-1 1/2"10'-4"30"x30" CONC.PAD FTG.6x6 COL.2-2x10 (DR)2-2x10 (FL)(2) TR3-9 1/2" LSL (DR)5'-5"2'-11"2'-9"2'-4"F
U
T
.
2
6
6
8
R.I. BATH5/0 BI-PASS FUT. 20682"FUT. BDRM. #5FUT. FAMILY ROOMCONC.CONC.(9'-0"x11'-10")(25'-62"x12'-6")W/ LADDER6042 GLIDERR.O.=5'-0"x3'-6"EGRESS PITFUT. 24683'-6"7'-4"7'-2"1,577 SQ. FT.13'-0"2868Interior BWP AboveUFER Ground-Provide 20' Rebar in footing and stubup near electrical service panel.
SCALE: 3/16" = 1'-0"MAIN FLOOR PLAN4907-00-BUYERPROJECT #BUYER S/OBUYER S/OREVISIONS:STARTED:AGENT:XX10-27-20 PERMIT10-30-20 REV.11-6-20 REV.11-30-20 REV.12-5-20 REV.OFSHEETP.H.TBTR DWGAS RANGEMICRO ABV. FLUSH OH. LNDRY.DRYERWASHER9' CLG. / LVPWIRE SH. 29 (OPT. UPPERS)39(VENT TO OUTSIDE)NOTE: - STD. BASE & CASING TO BE PRINCETON- 1/2 WALL w/ WD. CAP & INVERTED CASINGNOTE: 2X6 EXT. WALLS U.N.O.2X4 INT. WALLS U.N.O.- 42" UPPER CABINETSDOOR ROUGH OPENINGS:83" HEIGHT82" OVER VINYLCERAMIC TILE & WOOD82" OVER CARPETSRO = SHEET ROCKED OPNGBIFOLD DOORS:PREHUNG UNITS:2" WIDER THAN DOOR(EXAMPLE: 2668 )1 3/8" WIDER THAN DOORFINISH SIZE NOTED ON PLANCO = CASED OPENING ( WOOD )(EXAMPLE: 2668 )FINISH SIZE NOTED ON PLANRO. 1 1/2" WIDER, 83" HIGHR.O. 1" WIDER, 83" HIGHCONCRETE DRIVENOTE:REF.49KITCHEN9' CLG. / LVP12'-3" x 12'-6" (155 SQ. FT.)59BUILT-INS
793-14" LVLGREAT ROOM9' CLG. / LVP FLR.42" GAS F.P.12'-8" x 13'-0" (167 SQ. FT.) / LVP42" W. CONC. SIDEWALKOPT.FIBRGLS.60x36 SHWR.UNIT5'-0"210682-9 1/2" LSL2x6 FOYER9' CLG. / LVP6'-11" x 7'-1" (51 SQ. FT.)PORCHCONCRETEO. BATH9' CLG. / LVP2x6 WALLS U.N.O.4" SLOPED CONC.GARAGE CEIL. TO BE 5/8" TYPE 'X'GYP. BD. WALLS TO BE 1/2" GYP.SHEATHING. ALL WALLS & CEILINGS TOHAVE ONE COAT FIRETAPEGARAGESLOPE CONC.6'x8' PATIO DR.16'x7' O.H.D.R.O. 16'-1" FRAMINGO. CLST8' CLG. / CARPET36" VAN. BATH 2BEDROOM #226683648 SH @ 8'9' CLG. / CARPET9' CLG. / LVP60" 1/2 WALL w/ WD. CAPMANUF. TRUSSES
24 O.C.
OPT. BUFFET CABS.(12'-0"x12'-0")EXTERIOR FLOOR PLAN DIMENSIONSARE TO OUTSIDE OF SHEATHING, INTERIORDIMENSIONS ARE TO FRAMING.NOTE: ALL DRS/ WIN.'S REQUIRE 4" ON SIDES FOR CASINGNOTE: 2X6 EXT. WALLS U.N.O.2X4 INT. WALLS U.N.O.HEADER SPANS:UP TO 4'-11'' = 1 TRIMMER5'-0'' AND BIGGER = 2 TRIMMERSUNLESS NOTED OTHERWISEINDICATES LOCATION OF SOLID BRG.32x60FGLS.
TUB / SH
(134 SQ. FT.)OWNERS BDRM.9' CLG. / CARPET(12'-6"x13'-0") (164 SQ. FT.) SMOKECM / SD2 - 4072 SH @ 8'DN 17 R (10" T.,7-3/4" MAX. R.)2x68/0 H. SOFFITMANUF. TRUSSES
24 O.C.12" LP COL.* BEADBD. CLG.ATTIC
ACCESSAPPROX. 490 SQ. FT.MUDRM.9' CLG. / LVPBENCH / APPROX. 9'-0'' CLG. @ MAIN LEVELAPPROX. 1,577 SQ. FT. HOOKS3068 MTL.3080 MTL.
R&SH
2 - 20682668R&SH24682668 2068R&SHR&SH
LINENSH.9' CLG. / CARPET9' CLG. 8' SOFFIT
2
8
6
88' SOFFIT(5) SH.(5) SH.9' CLG. / LVP 2
6
6
8
R&SH
R&SH
36" VAN. LIN.CAB. 30683068 PKT.FLDG. C'TOP.
(OPEN UNDER)2 - 4072 SH @ 8'60" VAN. DINING9' CLG. / LVP FLR.10'-0" x 9'-0" (90 SQ. FT.)3672 SH @ 8'3672 SH @ 8'4872 PICT. @ 8'MANUF. TRUSSES
24 O.C.40'-0"15'-0"12'-0"8'-10"11'-6"12'-11"6'-9"56'-0"
6'-0"50'-0"
12'-8"5'-0 1/2"5'-5 1/2"12'-8 3/4"7"3'-11"5'-2 1/2"4'-4 3/4"
6'-2 1/4"6'-6 1/2"
56'-0"
1'-0"28'-0"27'-0"
14'-4"13'-8"
3'-2"9'-0 1/2"11'-6"5'-0"
7'-6"
14'-6"
2'-6"40'-0"19'-0"21'-0"20'-0"13'-0"6'-0"6'-7"6'-5"10'-0"11'-0"10'-0"RADON VENT2x6PA4"7'-1"4"12'-3"2-7 1/4" LSL (DR)2-2x8 (DR)4"LP SOFFITSD SMOKECM / OPT. VAULT6919BUILT-INSOPT.
OPT. 2-2668 PKT.
2'-4 1/4"1'-10 1/2"
2424 AWN. @ 8'2424 AWN. @ 8'
2'-0 1/2"2'-0 1/2"
or 3068 BARN DR.OPT. EXP.ISLANDINDICATEDSTONE WHERE2448 SH @ 8'
5'-0"WD. STEP2'-9"4'-4"3'-9"2'-9"5'-4 3/4"6'-1 1/4"6'-1 1/4"4'-8 3/4"12'-11 1/4"7'-0 3/4"2'-0"1'-4"7'-10"15'-0 1/2"2'-7 1/2"2'-4"6'-2 3/4"3'-6"3'-0 1/2"3'-11 1/2"2'-8 3/4"2'-0"
4'-0"5'-0"12"CANT.9'-4"5'-2"
1'-3"2 3/4"3'-0"1'-6 3/4"6'-8"7'-8"4'-0"9'-8"
3'-9"3'-10"
3'-5"3'-5"3'-0"3'-0"3'-0"2-2x10
2-2x10 2-2x10
2-2x10
4 1/2"4 1/2"8'-10 1/2"MANUF. TRUSSES
24 O.C.FP CHASEFALSE2-9 1/2" LSL (CONT.)2-9 1/2" LSL2-2x10(2) TR(2) TR2-2x102-9 1/2" LSLP.H.TRTB4x4 TRTD. COL.593068 PKT.3'-5"SCREEN PORCH6x6 POSTS4x4 POSTSEXTERIOR SCREENINGW/ OPEN RAIL MIN. 36"OPT. DOORCONC. PATIO5'-0"10'-0"CONC. MICRO/ OVENOPT. UPGRADED KITCHENDWGAS COOKTOPHOOD VENT ABV.(VENT TO OUTSIDE)REF.KITCHENOPT. EXP.ISLANDTemperCS-PFCS-PF-Min. 15" clearance to anyobstruction from center ofW.C., 24" in front(typ).88
5907-00-BUYERPROJECT #BUYER S/OBUYER S/OREVISIONS:STARTED:AGENT:XX10-27-20 PERMIT10-30-20 REV.11-6-20 REV.11-30-20 REV.12-5-20 REV.OFSHEETSCALE: 1/4" = 1'-0"SECTION15N.T.S.HOUSE / DECK CONNECTION DETAIL45R-5 THERMAX ATINTERIOR FOUND.AS REQUIRED3/4" T & G FLOORNOTE: SUBFLOOR JOINTS SHALL BESTAGGERED FROM FLOOR TRUSS ORJOIST JOINTSR=0.61R=49.00R=50.25R=0.58R=.061TOTALTRUSSES - 24" OCBLOWN INSULATIONINTERIOR AIR FILMVAPOR BARRIER15/32" OSB SHTG.15# FELTEXTERIOR AIR FILMICE AND SNOW SHIELD30 YR. ARCH. ASPHALT SHINGLES5/8" GYP BDALUM. SOFFIT & FASCIA1/2" GYP BDINTERIOR AIR FILMTOTALSIDING PER SPECS2x6 STUDS 16" OCR=1.06R=R=R=21.00R=0.45R=0.17R=23.36VAPOR BARRIERFULL WALL BATT INSUL.EXTERIOR AIR FILMR=0.687/16" OSB SHTG.8" AGGREGATE6 MIL POLY. LAP SEAMS 12"10"
HEEL HT.1/2" GYP. SHEATHING ON GARAGE WALLS5/8" TYPE 'X' GYP. BD. ON GARAGE CEILS.18" FLOOR TRUSSES1'-8 1/4"
9'-1 1/8"T.O. FOUND.T.O. SUBFLR.T.O. PLATETRUSSES @ 24" O.C.(DESIGNED BY MFR)612R-49 INSUL.9'-4"GARAGE4" SLOPED CONC.W/ REBAR PERENGINEERS REPORT10'-0" POURED WALLDRAIN TILE 10" POURED WALLR-5 INSUL. ATINTERIOR FOUND.9'-1 1/8"O. BATHOWNERS BDRM.20x8 CONC. FTG.16x8 CONC. FTG.16x8 CONC. FTG.NOTE: TOP HUNG TRUSSESAT FRONT OF HOME(10'-0" H. FDN. WALL)SPRAY FOAM RIMSPRAY FOAM RIM8'-2" +/-FOUND. HELD IN 2"FOR INSULATION TYP.NOTE:(INSUL. FLUSH w/ SHTG.)CANT. 2x8 SILL PLT. 1-1/2"3 1/2" CONC. FLOOR2" RIGID INSULATIONR-10 w/ WATCHDOGWATERPROOF COATINGAROUND HOUSE FOUND.20x8 CONC. FTG.8 1/4"
6"HEEL HT.6128'-4"FUT. BDRM. #5R.I. BATH8 1/4"4"5'-6"8'-8"4"HEEL HT.JOISTW/ 2-3/8" LAG BOLTSICE & WATER EXTENDS5" UP SHEATING UNDERINSTALL TOP OF LEDGER3 5/8" BELOW TOP OF3/4" SUBFLOOR (THISALLOWS 5/4 X 4 THRESHOLDAT DOOR)HANGERTREATED 2X10 LEDGERRUN HOUSE WRAP BEHINDLEDGER (LEAVE 6" TAIL@ TOP, BOTTOM, & SIDES)HOUSEWRAP@ 24" O.C. -OR-EMBED 2" MIN.8 INCHES O.C. MAX OR EQUAL,W/ "LEDERLOK" FASTENERSCONT. 2X4 RIBBONSPRAY FOAM INSUL. R-21 MIN.RIM BOARDTREATEDJOISTJOISTRIMBD.SKIRT1"HOUSEEND OF DECKHOUSE LATERAL LOAD SIMPSON DTT1Z DECK-TOCONNECTOR - (4) PER DECKOR 8-10DX1 1/2" NAILS6-SD#9X1 1/2" SCREWSHDG WASHER OR SDWH 3/8" HDG LAG SCREW WITHTIMBER-HEX HDG SCREW(SHOWN) INTO TOP PLATE,STUDS, OR HEADERCONT. 2X8 RIBBONDRAIN TILE3/4" WASHED ROCKCONTINUOUSUNDER SLAB0'-16"SILT FABRICFOUNDATION WALLCONC. FTG.4" DRAIN TILE 2SCALE: NO SCALE5TOP OF FDN.RIM DETAIL3SCALE: NO SCALE52" RIGID INSULATIONR-10 w/ WATCHDOGWATERPROOF COATINGAROUND HOUSE FOUND.2" RIGID INSULATIONR-10 w/ WATCHDOGWATERPROOF COATINGAROUND HOUSE FOUND.2x8 TRTD. SILLSHEATHING FLUSHWITH INSULATION NOTE:FOUNDATION TO BEHELD IN 2" FROMSHEATHING & OUTSIDEDIMENSIONS.CANTED 1-1/2"
6907-00-BUYERPROJECT #BUYER S/OBUYER S/OREVISIONS:STARTED:AGENT:XX10-27-20 PERMIT10-30-20 REV.11-6-20 REV.11-30-20 REV.12-5-20 REV.OFSHEETSCALE: 1/4" = 1'-0"SECTION16N.T.S.PORTAL FRAME DETAIL26N.T.S.RADON DETAIL36SIMPSON STRONG TIE Ab46z4" LEDGEHEADERHURRICANE CLIP ATTACHEDTO COLUMN& BEAM11 7/8" OSB STRINGERW/ 2X4 BRACING10 1/2" BULLNOSE LSL TREAD1X8 PINE S4S RISERNOTE:MAX RISE= 7 3/4"MIN. RUN= 10"6'-8" CLEAR HEADROOMBATH 2BEDROOM #2GREAT RM.3/4" T & G FLOORNOTE: SUBFLOOR JOINTS SHALL BESTAGGERED FROM FLOOR TRUSS ORJOIST JOINTSALUM. SOFFIT & FASCIA8" AGGREGATE6 MIL POLY. LAP SEAMS 12"18" FLOOR TRUSSES1'-8 1/4"
9'-1 1/8"T.O. SUBFLR.T.O. PLATETRUSSES @ 24" O.C.(DESIGNED BY MFR)R-49 INSUL.9'-4"W/ REBAR PERENGINEERS REPORT10'-0" POURED WALLDRAIN TILE 10" POURED WALLR-5 INSUL. ATINTERIOR FOUND.20x8 CONC. FTG.16x8 CONC. FTG.NOTE: TOP HUNG TRUSSESAT FRONT OF HOME(10'-0" H. FDN. WALL)SPRAY FOAM RIMSPRAY FOAM RIM8'-2" +/-FOUND. HELD IN 2"FOR INSULATION TYP.NOTE:(INSUL. FLUSH w/ SHTG.)CANT. 2x8 SILL PLT. 1-1/2"3 1/2" CONC. FLOORCONC. STOOP2" RIGID INSULATIONR-10 w/ WATCHDOGWATERPROOF COATINGAROUND HOUSE FOUND.PORCH12" SQ.LP COLUMN20x8 CONC. FTG.10"
HEEL HT.612T.O. FOUND.MECH. / STORAGEFUT. FAMILY ROOM6128'-4"KITCHEN8 1/4"4x4 TRTD. COL.2x OVER 10" TRIM2535R-5 THERMAX ATINTERIOR FOUND.AS REQUIRED8" BOXED HEADERSIMPSON STHD14 HOLD DOWNSIMPSON LSTA36 STRAP ON INSIDE FACE OF WALL5/8" ANCHOR BOLT1/2" OSB SHEATHINGHEADER- SEE PLAN FOR SIZEFASTEN SHEATHING TO HEADER WITH 8d COMMON ORGALVANIZED BOX NAILS IN 3" GRID PATTERN ASSHOWN, AND 3" O.C. IN ALL FRAMING MEMBERS TYP.SHEATHING SPLICE (IF NEEDED) MUST BELOCATED WITH-IN 24" OF THE MID HEIGHTOF THE DOOR OPENING. PROVIDE 2-2X6BLOCKING BEHIND SPLICEFASTEN TOP PLATE TO HEADER WITH2 ROWS OF 16d SINKER NAILS 3" O.C.BLOCK BACK SIDE OF HEADER FLUSH WITH STUDSAT STRAP LOCATIONSUNEXCAVATED SOILALL SLABS WILL HAVE A MIN. 4" CLEAN AGGREGATE, COVERED BY6 MIL POLY. THIS POLY WILL HAVE 12" LAP AT ALL SEAMS. ALL TEARS ORPUNCTURES WILL BE SEALED OR COVERED BY POLY. ALL OPENINGS WILL BESEALED USING POLYURETHANE CAULK OR ELASTOMERIC SEALANT AT ALL OPNGS.AN INSTALLED 3" GASTIGHT PVC PIPE WILL BE CONNECTED TO THE DRAINTILE SYSTEM. A "T" FITTING WILL BE INSTALLED WITH 10 L.F. EACH ENDOF THE "T", OF PERFORATED PIPE, INTO THE DRAIN TILE SYSTEM. THE SHORTEST ROUTE WILL BE USED TO EXIT THE ROOF SYSTEM, WITH A MAX. OF 2 90DEGREE ELBOWS. IN UNCONDITIONED AREAS, THE RADON EXHAUST PIPE WILLBE INSULATED WITH AN R4 SLEEVE. THIS PIPE WILL BE LABELED "PASSIVERADON" AT ALL ACCESSIBLE LOCATIONS.AT ROOF EXIT LOCATIONS, MAINTAIN A 10' DISTANCE TO ANY WINDOWLOCATION, 2' BELOW EXHAUST POINT AND ANY ADJACENT STRUCTURE. THELOCATION OF THE EXIT POINT, IN TRUSS AREA, WILL BE CLEAR OF ANYOBSTRUCTIONS WITHIN 24" HORIZONTALLY AND 36" VERTICALLY. INSTALL AN OUTLET AND PULL CHORD LIGHT FOR FUTURE EXHAUST FANADDITION.
7907-00-BUYERPROJECT #BUYER S/OBUYER S/OREVISIONS:STARTED:AGENT:XX10-27-20 PERMIT10-30-20 REV.11-6-20 REV.11-30-20 REV.12-5-20 REV.OFSHEETSCALE: 3/16" = 1'-0"ROOF PLAN17SADDLE
NOTE: SEE ROOF TRUSS LAYOUTFOR TRUSS DIRECTION AND GIRDER LOCATIONSPROVIDED BY MANUFACTURERPROVIDE ATTIC VENTILATION EQUAL TO 1/150thATTIC AREA. IF 50% OR MORE IS PROVIDED INUPPER PORTION OF THE ROOF AND REMAINDERIS PROVIDED IN SOFFIT VENTS, IT MAY BEREDUCED TO 1/300th ATTIC AREA.ICE AND WATER SHIELD6'-0" IN FROM EAVES1'-6" ON EACH SIDE OF VALLEYWHERE WALLS MEET ROOFICE & WATER SHIELD SHOULDRUN UP WALL 1'-6" AND OUTFROM WALL 1'-6"NOTE: NOTE: NOTE: 1'-6"1'-6"12:12RIDGE
RIDGE1'-6"1'-6"1'-6"6:12 6:1212:1212:1212:12RIDGE
RIDGE
12:1212:12RIDGE
6:12
12:121'-6"1'-6"1'-6"12:12
SCALE: 1/4" = 1'-0"MAIN FLR. ELECTRICAL PLAN8907-00-BUYERPROJECT #BUYER S/OBUYER S/OREVISIONS:STARTED:AGENT:XX10-27-20 PERMIT10-30-20 REV.11-6-20 REV.11-30-20 REV.12-5-20 REV.OFSHEETSCALE: 1/4" = 1'-0"LOWER LEVEL ELECTRICAL PLANSSTVABV. FP.NOTE:TECH TUBETVW.P.
G.F.I.P.
S3S3 LTS.PENDANT3SSC/L7'-6"3'-2"4'-9 1/2"TVDWGAS RANGEMICRO ABV.LNDRY.DRYERWASHER(VENT TO OUTSIDE)REF.KITCHENGREAT ROOMFOYERPORCHO. BATHGARAGEO. CLSTBATH 2BEDROOM #2OWNERS BDRM. SMOKECM / SDATTIC
ACCESSMUDRM.DININGSCREEN PORCHSD SMOKECM / GDOG.F.I.P.SG.F.I.P.G.F.I.P.
G.F.I.P.W.P.SSSSSSS3S3S3
S
G.F.I.P.
S3S3
S
S3S3S3S3SS SS
DISPSSS3TO LIGHTSSG.F.I.P.G.F.I.P.SSSSS12'-3"6'-6 9/16"DUPLEX CONVENIENCE OUTLETDUPLEX OUTLET ABOVE COUNTERWEATHERPROOF DUPLEX OUTLETHALF-SWITCHED DUPLEX OUTLETDUPLEX OUTLET IN FLOOR220 VOLT OUTLETWALL SWITCHTHREE-WAY SWITCHFOUR-WAY SWITCHCEILING MOUNTED INCANDESCENT LIGHT FIXTUREWALL MOUNTED INCANDESCENT LIGHT FIXTURERECESSED INCANDESCENT LIGHT FIXTURELIGHT FIXTURE WITH PULL CHAINTRACK LIGHTFLOURESCENT LIGHT FIXTUREEXHAUST FANEXHAUST FAN/LIGHT COMBINATIONCHIMES (OPTIONAL)SMOKE DETECTORTELEPHONE (OPTIONAL)TELEVISION (OPTIONAL)THERMOSTATELECTRIC METERELECTRIC PANELSPEAKER (OPTIONAL)TVTMCHSDP.C.SSS43W.P.ELECTRICAL KEYDUPLEX OUTLET (GROUND FAULT PROTECTED)G.F.I.P.RECESSED INCANDESCENT EYE BALL FIXTURECARBON MONOXIDE DETECTORCMGARAGE DOOROPENER OUTLETGDOFLUORESCENTLIGHT PER SPECFAN/LIGHT COMBOPREWIRE, PROVIDEADEQUATESUPPORT4 BULB FIXTURE3 BULB FIXTURE200 AMP SERVICELIGHTING PACKAGE: T.B.D.LINE TO DRYER: T.B.D.G.F.I.P.EXCH.AIRFURNF.D.WHMECH. / STORAGEWSFUT. BDRM. #5FUT. FAMILY ROOMR.I. BATHSUMPH20OPT.RADON VENT SMOKECM / SS3STO LIGHTA/C UNITw/ BRACKETG.F.I.P.G.F.I.P.CIRCUIT FOR CHEST FREEZERFIELD VERIFY LOCATION
9907-00-BUYERPROJECT #BUYER S/OBUYER S/OREVISIONS:STARTED:AGENT:XX10-27-20 PERMIT10-30-20 REV.11-6-20 REV.11-30-20 REV.12-5-20 REV.OFSHEET49" +/-NO HEARTHPER SPECS12" SURROUND @ FRONT ONLY42" W.GAS F.P.R.O. 42"x38 1/4" x 16 1/4"GATHERING RM. F.P. ELEV. 91SCALE: 3/8"=1'-0"MANTLE PER SPECS3'-0"3'-0"5'-0"4KITCHEN ELEV.9SCALE: 3/8"=1'-0"67" FIN.2KITCHEN ELEV.9SCALE: 3/8"=1'-0"2'-0"REFRIG.SPACE2'-0"3'-0"24" DEEPCROWN MLDGEND PANEL2'-0"3KITCHEN ELEV.9SCALE: 3/8"=1'-0"(SHTRCK. @ SIDES)60" TV(REF. ONLY)3'-8 1/2"2'-0"3'-0"2'-0"12'-6"D.W.SPACESINK1'-6"3'-0"CROWN 4'-6"3'-0" MLDG2'-0"2'-6"15" D.MICRORANGESPACE(VENT TOOUTSIDE)1'-6"1'-9"3'-0"OPT. BUILT-INS3'-0"1'-0"1'-9"3'-0"12'-3"1'-0"OPT. BUILT-INS3'-8 1/4"2'-11 1/4"5'-0"BATH 2 ELEV.96SCALE: 1/4"=1'-0"7'-0"MIRRORSPACEWASH.LNDRY. ELEV.SCALE: 3/8"=1'-0"DRYERSPACE30"CROWN MOULDING98C'TOPRAISEDOPT. 2" SUPPORT w/ FRONTLOAD W&D3'-5"2'-11 1/4"3'-0"
7'-0"WALL MOUNT7'-9"O. BATH ELEV.97SCALE: 3/8"=1'-0"3'-0"1'-9"3'-0"MARBLE C'TOP.WHITE CULT.NOTE:OPT. w/ RAISED TOPWALL MOUNTMIRRORMARBLE C'TOP.WHITE CULT.NOTE:5OPT. BUILT-INS @ DINING ELEV.9SCALE: 3/8"=1'-0"CROWN MOULDINGGRANITE TOP w/ OPT. BUILT-INSGLASSGLASSGLASSGLASS NOTE: PUCK LTS. ATGLASS DOORS15" D.1'-9"1'-9"5'-5 1/4"2'-6"2'-6"49" +/-NO HEARTHPER SPECS12" SURROUND @ FRONT ONLY42" W.GAS F.P.R.O. 42"x38 1/4" x 16 1/4"GATHERING RM. F.P. ELEV. 91SCALE: 3/8"=1'-0"MANTLE PER SPECS3'-0"3'-0"5'-0"4KITCHEN ELEV.9SCALE: 3/8"=1'-0"67" FIN.2KITCHEN ELEV.9SCALE: 3/8"=1'-0"2'-0"REFRIG.SPACE2'-0"3'-0"24" DEEPCROWN MLDGEND PANEL2'-0"3KITCHEN ELEV.9SCALE: 3/8"=1'-0"(SHTRCK. @ SIDES)60" TV(REF. ONLY)3'-8 1/2"2'-0"3'-0"2'-0"12'-6"D.W.SPACESINK1'-6"3'-0"CROWN 4'-6"3'-0" MLDG2'-0"2'-6"15" D.MICRORANGESPACE(VENT TOOUTSIDE)1'-6"1'-9"3'-0"OPT. BUILT-INS3'-0"1'-0"1'-9"3'-0"12'-3"1'-0"OPT. BUILT-INS3'-8 1/4"
BW07-00-BUYERPROJECT #BUYER S/OBUYER S/OREVISIONS:STARTED:AGENT:XX10-27-20 PERMIT10-30-20 REV.11-6-20 REV.11-30-20 REV.12-5-20 REV.SHEETN.T.S.MAIN LEVEL BRACEWALL1BWN.T.S.BRACEWALL DETAILS2BWLNDRY.DRYERWASHERKITCHENGREAT ROOMFOYERPORCHO. BATHGARAGEO. CLSTBATH 2BEDROOM #2OWNERS BDRM.ATTIC
ACCESSMUDRM.DININGGARAGE PORTAL FRAMING PER BUILDING CODE IRC R602.10.6.4BRACED WALL METHOD CS-WSP3'-2" PANEL4'-0" PANEL 4'-0" PANEL4'-0" PANEL4'-0" PANEL
4'-0" PANEL
BRACED WALL
LINE 1BRACED WALLLINE ABRACED WALLLINE CBRACED WALL
LINE 2
4'-0" PANEL4'-0" PANEL4'-0" PANEL 4'-0" PANEL
3'-2" PANEL3'-5" PANEL3'-5" PANEL6'-7" PANEL3'-1" PANELBRACED WALLLINE B8'-0" GYP. PANEL8'-0" GYP. PANEL1'-4" PANEL1'-4" PANELMIN. 3''x11 1/4'' NET HEADER(STEEL HDR. PROHIBITED)EXTENT OF HEADER W/ SINGLE PORTAL FRAMEONE BRACED WALL PANEL10'-0'' MAX. HEIGHT(TOP OF HDR.)TOP OF FDN.TOP OF CONC FLOOR AT OPENINGMIN. 2-2x4 FRAMINGSTUD POSTCONTINUOUS HEADER WITH DOUBLE PORTAL FRAMESTWO BRACED WALL PANELS6' TO 18' OPENINGFASTEN TOP PLATE TO HEADER W/ 2ROWS OF 16d SINKER NAILS @ 3'' O.C. TYP.1000 LB. STRAP OPPOSITE SIDE OF SHEATHINGFASTEN SHEATHING TO HEADER W/ 8dCOMMON OR GALV. BOX NAILS IN 3'' GRIDPATTERN SHOWN AND 3'' O.C. IN ALLFRAMING(STUDS, BLOCK'G AND SILLS)TYP.MIN. WIDTH PER TABLE R602.10.53/8'' MIN. WOOD STRUCTURAL PANEL SHEATH'G.MIN. 2-2x4MIN. 4200 LB. TIE DOWN DEVICE(EMBED INTOFOUNDATION AND NAILED INTO FRAMINGMIN. (2) 1/2'' DIA. ANCHOR BOLT INSTALLED PER R403.1.6WSEE LEFT FORTYP. PORTALFRAME CONST.FOR A PANEL SPLICE(IF NEEDED) PANELEDGES SHALL BEBLOCKED AND OCCURWITHIN 24'' OF MID-HEIGHT. ONE ROW OFTYP. SHEATH'G. TOFRAMING NAILING ISREQUIRED.IF 2x4 BLOCK'G. IS USEDTHE 2x4'S MUST BE NAILEDTOGETHER W/ 3 16dSINKER NAILSW/ 2''x2''x3/16'' PLATE WASHER12'-0'' MAX. HEIGHT(TOP OF WALL)FULL HEIGHT OF WALL - SEE TO RIGHT FOR SPLICESPONY WALL HT.EXTENT OF HEADERTENSION STRAP PERTABLE R602.10.6.4 (ONOPPOSITE SIDE OFSHEATHINGANCHOR BOLTSPER SECTIONR403.1.6BRACED WALL LINECONTINUOUSLYSHEATHED WITHWOOD STRUCTURALPANELSTOP OF FLOOR AT OPENINGFLOOR FRAMING ASSEMBLY PER PLAN W/ WOOD STRUCTURAL PANEL SHEATHINGTOP OF FLOOR AT OPENINGFLOOR FRAMING ASSEMBLY PER PLANWOOD STRUCTURAL PANEL SHEATHINGTO TOP OF BAND OR RIM JOISTNAIL SOLE PLATE TO FLRFRAMING PERTABLE R602.3(1)(2) FRAMING ANCHORS APPLIED ACROSSSHEATHING JOINT WITH A CAPACITY OF670# IN HORIZ. AND VERT. DIRECTIONSSEE LEFT FORTYP. PORTALFRAME CONST.ON CONCRETE FOUNDATIONON RAISED WOOD FLOOR - FRAMING ANCHOR OPTIONTOP OF FLOOR AT OPENINGFLOOR FRAMING ASSEMBLY PER PLAN W/ WOOD STRUCTURAL PANEL SHEATHINGTOP OF FLOOR AT OPENINGFLOOR FRAMING ASSEMBLY PER PLANWOOD STRUCTURAL PANEL SHEATHINGTO TOP OF BAND OR RIM JOISTNAIL SOLE PLATE TO FLRFRAMING PERTABLE R602.3(1)SEE LEFT FORTYP. PORTALFRAME CONST.ON RAISED WOOD FLOOR - OVERLAP FLOOR OPTIONMIN. OVERLAP 9 1/4''WOOD STRUCTURAL PANEL SHEATHINGCONTINUOUS OVER BAND OR RIM JOISTMIN. OVERLAP 9 1/4''ATTACH TO RIM/BAND JOIST W/ 8dCOMMON NAILS AT 3'' O.C. AS SHOWNDBL TOP PLATEBOTTOM PLATESTUDS AT 16'' O.C.W/ 6d NAILS @ 6'' O.C.4'-0"8'-0'' MIN., SEE PLANINTERMEDIATE6''3"W/ 6d NAILS @ 3'' O.C.EDGES NAILED
Created by BAM version 052009
New Construction Energy Code Compliance Certificate
Place your
logo here
Per N1101.8 Building Certificate. A building certificate shall be posted in a permanently visible location inside
the building. The certificate shall be completed by the builder and shall list information and values of
components listed in Table N1101.8.
Date Certificate Posted
Mailing Address of the Dwelling or Dwelling Unit City
17999 Grantham lane lakeville
Name of Residential Contractor MN License Number
Mid State Plumbing & Htg PM64995
THERMAL ENVELOPE RADON SYSTEM
Insulation Location
Total R-Value of all Types ofInsulationType: Check All That Apply X Passive (No Fan)Non or Not ApplicableFiberglass, BlownFiberglass, BattsFoam, Closed CellFoam Open CellMineral FiberboardRigid, Extruded PolystyreneRigid, IsocynurateActive (With fan and monometer or
other system monitoring device)
Other Please Describe Here
Below Entire Slab
Foundation Wall R-15 x Exterior 2" CertiStud -- Interior 3/4" Thermax
Perimeter of Slab on Grade R-10 x
Rim Joist (Foundation)N/A
Rim Joist (1st Floor+)N/A Interior
Wall R-21 x
Ceiling, flat R-49 x Attic
Ceiling, vaulted R-38 x
Bay Windows or cantilevered areas N/A Interior
Bonus room over garage N/A Exterior & Interior
Describe other insulated areas
Windows & Doors Heating or Cooling Ducts Outside Conditioned Spaces
Average U-Factor (excludes skylights and one door) U: 0.29 X Not applicable, all ducts located in conditioned space
Solar Heat Gain Coefficient (SHGC):0.28 R-value
MECHANICAL SYSTEMS Make-up Air Select a Type
Appliances Heating System Domestic Water Heater Cooling System X Not required per mech. code
Fuel Type Natural Gas Natural Gas Electric Passive
Manufacturer Bryant Bradford White Bryant Powered
Model 912S MITW50 113A Interlocked with exhaust device.
Describe:
Rating or Size Input in
BTUS:42973 Capacity in
Gallons:
50 Output in
Tons:2 X RenewAire Exchanger EV90
Structure's Calculated Heat Loss: Heat
Gain:19,737 Basement and Duct in Floor trusses
Efficiency
AFUE or
HSPF%
92.00% SEER: 13
Calculated
cooling load:
19,737 Cfm's
" round duct OR
Mechanical Ventilation System " metal duct
Combustion Air Select a Type
Not required per mech. code
Select Type X Passive
Heat Recover Ventilator (HRV) Capacity in cfms:Low: Variable High:Other, describe:
x Energy Recover Ventilator (ERV) Capacity in cfms:53.77 Speed High:107.54 Location of duct or system:
Continuous exhausting fan(s) rated capacity in cfms:6 " 0
Location of fan(s), describe: Mechanical room in Garage Cfm's
Capacity continuous ventilation rate in cfms:ERV 130 @ 50%= 63cfm X " round duct OR
Total ventilation (intermittent + continuous) rate in cfms: " metal duct
NEW RESIDENTIAL CONSTRUCTION SWPPP VERIFICATION
This form must be completed and submitted with all new residential permit applications.
A National Pollutant Discharge Elimination System (NPDES) Construction Stormwater Permit is
required for “Construction activity that results in land disturbance of equal to or greater than one (1)
acre or if a project is part of a common plan of development that will ultimately disturb greater than
one (1) acre,” (NPDES Permit, Section 1.2).
Project Site Address: _____________________________________________________________________
Company Name: _________________________________________________________________________
*Primary Company Contact: _________________________________________________________________
*Should a site be deemed noncompliant, this individual will be notified
Phone #: ____________________________ Email: ______________________________________________
If you are not covered under a NPDES Construction Stormwater Permit administered by the
Minnesota Pollution Control Agency (MPCA), an erosion and sediment control plan MUST be
approved as part of the residential building permit application.
“Permittees must ensure a trained person will inspect the entire construction site at least once every
seven (7) days during active construction and within 24 hours after a rainfall event greater than ½
inch in 24 hours,” (NPDES Permit, Section 11.2).
The City of Lakeville reserves the right to request weekly inspection logs. The City of Lakeville may
issue a STOP WORK ORDER; withhold building inspections; or, draw on securities/escrows to
bring the site into compliance with the NPDES Construction Stormwater Permit (MN R 100001) or
erosion and sediment control plan.
Contact information of person CERTIFIED to provide weekly onsite erosion and sediment control
inspections and corrective actions:
Name: ____________________________________ Company: ___________________________________
Phone # (24 hr Contact): ______________________ Email: ______________________________________
Entity that Provided Training: __________________________ Certification Expiration Date: ____________
NOTE: Prior to any land-disturbing activity, all erosion and sediment controls must be installed
I understand the above information to be accurate and I have read, understood, and accepted all terms and conditions of the NPDES Permit (MN R 100001).
Signature: ________________________________________________ Date:_________________________
Contact the City of Lakeville with questions at erosion@lakevillemn.gov or 952-985-4500
11/13/2020 X
KP