Loading...
HomeMy WebLinkAbout19982 Hiawatha Ct Survey(1017.1)(1012.4)15HIAWATHA COURT10.5010.5425.3368.36FD IPOS 34.38HUB=1013.04OS 27.40HUB=1013.24OS 23.75HUB=1015.48OS 30.01HUB=1015.24R:1014.11R:1011.74C.O.C.O.GAR FLOOR1013.34SERVFD IP151010555562.46 S03°27'19"E S88°03'16"W141.89138.07S80°02'07"W15.60N09°57'53"WΔ=8°01'05"R=475.0066.47VACANT LOT9.0%DRAINAGE &UTILITY EASEMENTGARAGEGARAGEPROPOSEDHOUSEPORCHW.W.W.W. 5.92 21.50 24.50 11.17 17.33 10.00 3.00 14.66 2.83 17.00 33.83 11.66 4.00 9.67 14.17 20.50 2.00 11.001017.61017.51015.81014.41012.01012.11015.11014.91014.91014.71014.21014.91013.41013.1(1017.50)(1017.0)(1013.0)(1018.0)(1016.0)(1013.2)EX. SODEX. SODEX. SOD1012.41017.61014.01014.4(1017.1)(1016.0)(1017.0)1019.01016.01017.9(1015.0)(1016.0)1012.6(1012.6)23.018.0EXPOSE FOUNDATIONAS NEEDEDDENOTES EXISTING CATCH BASINDENOTES EXISTING HYDRANTDENOTES EXISTING SANITARY MANHOLEDENOTES EXISTING STORM MANHOLEDENOTES EXISTING COMMUNICATION BOXDENOTES EXISTING ELECTRIC BOXDENOTES EXISTING SERVICE OR CLEANOUTDENOTES IRON MONUMENT FOUNDDENOTES IRON MONUMENT SETDENOTES EXISTING POWER POLEDENOTES EXISTING LIGHT POLEDENOTES EXISTING CONSERVATION POSTOR WET LAND BUFFER POSTDENOTES EXISTING TREEPPLP8" TREE000.0DENOTES WOOD HUBDENOTES NAILDENOTES EXISTING RETAINING WALLDENOTES PROPOSED RETAINING WALLDENOTES EXISTING ELEVATIONDENOTES PROPOSED ELEVATIONDENOTES AS BUILT ELEVATION(000.0)000.0DENOTES EXISTING TREELINEDENOTES DIRECTION OF SURFACE DRAINAGEDENOTES EXISTING FENCELEGENDDENOTES EXISTING F.E.S.LOT AREA : 10,168 SQ. FT.HOUSE AREA : 1,891 SQ. FT.PORCH AREA : 166 SQ. FT.TOTAL COVERAGE AREA : 2,057 SQ. FT. (20.2%)Legal Description:= FINISHED GARAGE FLOOR ELEVATION= BASEMENT FLOOR ELEVATION= TOP OF FOUNDATION ELEVATION(1017.50)(1017.83)(1009.83)1. No specific soils investigation has been performed on this lotby the surveyor. The suitability of the soils to support thespecific house is not the responsibility of the surveyor.2.No title information was provided for this survey. This surveydoes not purport to show all easements of record.3. See architectural plans for final building dimensions.BENCHMARK: TNH AT LOT 1 BLOCK 1. ELEVATION = 1011.79CERTIFICATE OF SURVEYNOTES 1. 1009.1 LOW FLOOR 2. ROCK CONSTRUCTION ENTRANCE AT DRIVEWAY. 3. EROSION CONTROL AT GRADING LIMITS. 4. MAXIMUM DRIVEWAY WIDTH AT RIGHT-OF-WAY IS 24FT WITHOUT PERMIT.AREAS:Zoning = RS-4FY - 20' House, 25' GarageSY - 7' Interior, 20' CornerRY - 30'SY Buffer - 30'RY Buffer - 50'*Draintile connection required.ENGINEERING REVIEWEDDate:__________________01/27/2021lvlasatyThe curb box, drain tile cleanout, and catchbasin(if applicable) must be inspected andaccepted before As-Built escrow monies willbe released. All structures must be flushwith the sod. This will be scheduled with thelandscape inspection.*Maintain 6" between bottom of siding and sod.*No structures in easements.EROSION CONTROL MUST BE INSTALLED BEFORE EXCAVATION19982 Hiawatha Ct