Loading...
HomeMy WebLinkAboutLA188210SIGN PERMIT & ELECTRONIC SIGN LICENSE APPLICATION City of Lakeville - Planning Departrnent 24195 Holyoke Avenue - Lakeville, MN 55044 952. 985.4 42fr - www" nahevi"Ileryln . S*X THE FOLLOWING INFORMATION MUST BE INCLUDED WITH YOUR APPLICATION: tr Payment for amount of permit. I Forfreestanding/monument/py.lon sigur -a siie plan with selback frorn propertyline dimensions and art work with dimensions of sign, and engineered design for footings and foundation. O For wall sign, art work with dimensions of sign and drawings of building fagade showing location of sign. tr lf illuminated or if electrical services are needed, a separate elec-trical permit is required. tr lf leased space, need to include a letter of approval from the property owner. Applicant Signature:?lL7 tTL BUSINE$S INFORMATION Contact - Iosh McDonnqll Day Phone Email Address ioshuamcdonnell@airsas.com 5s044 # 952-747-0171 City Lakeville zip 21229 Ave MN PROPERry ovvfitER city Eaflan . . state MN . zip Contact Guidq Glipri Day Phone # 55121 651 -452-2700 11 Email Address seiori@grazzini.com Grazzini Brothers & SIGN CONTRACTOR AOOress 1711 Scheurinq Roa Phone #804.325.1 1 3 1 Company Name Iones Sign Company Inc City De Pere stut* WI zip 541 15 Email Address Contact Kerri Sabol permitting@i onessign. com E Electronic ($100 Per sign Plus completion of electronic sign license, see Page 2) {1000.4114) EI Permanent {$ZS per sign) (1000.4114) tr Temporary {$S0 per event, up to 60 days per year. Max of one temp sign displayed at a time.) (1000.4114) Temporary sign displayed dates: START DATE END DATE Square feet 28.8 _ E Freestanding: Face Width- Height_ $+ ft- overall sjgn Height - Setbacks: Front Side width- Height Square Feet E walt sign Height:3.61 Siqn Tvpe and Dime,nsionp Display location E Temporary Sign width I' SIGH DESCRIPTION llluminated Sion: EI lnternally illuminated I Externally illuminated tl "Not illuminated Typg of Work: tr New Sign tr Replacement Sign tr Alter Existing Sign Chanseable, Copy; E No Changeable Copy tl Manuat Changeable Copy I Electronic Changeable Copy {Slectro*ic s€fi w-iH requir+ annu*l licenss revisly & renerval, sse Page 2) Applicant Printed Name: Kerri Sabol a LA188210 SIGN PERMIT & ELECTRONIC SIGN LICENSE APPLICATION Page 2 Electronic Display/Changeable Copy Sign License By signing below you are certifying the electronic signage meets the following performance standards: 1.The display sign shall not change more than once every seven (7) seconds. 2.The display sign shall not include scrolling, flashing, animation, or other effects. 3.The display must be static and the transition from one static display to another must be instantaneous without special effects. 4.The display image or message must be self-contained, without continuation in content to the next image or message. 5.The brightness of the sign shall not exceed 5,000 NITS after sunrise and before sunset or 500 NITS after sunset and before sunrise each day. 6.The sign shall be equipped with an automatic dimmer control or other mechanism that automatically controls the sign’s brightness to comply with this condition. 7.The display must be designed and equipped to freeze the device in one position if a malfunction of the electronic display occurs. 8.The display must also be equipped with a means to immediately discontinue the display if it malfunctions, and the sign owner must immediately stop the electronic display when notified by the City that it is not complying with the stipulations of this section. 9.The sign shall comply with Chapter 23 of the Zoning Ordinance. Signature_______________________________________ Date______________________________ Print Name______________________________________ Email ________________________________ EXPIRATION AND RENEWAL OF LICENSE: •All licenses expire on December 31st of each year. •License may be renewed only by making application as provided in Section 3-22-4 of the City Code. •Application for renewal shall be made at least sixty (60) days before the expiration date. •Each renewal license shall be issued for a maximum period of one (1) year. •Annual license renewal fee is $50.00 Office Use Only Sign Permit Type: Permanent Sign _____ Temporary Sign _____ Electronic Sign _____ Work Type: New _____ Addition _____ Repair _____ Demolish_____ Replace _____ Alter/Remodel _____ Move _____ Owner: Public _____ Private _____ Zoning District: Commercial _____ Industrial _____ Residential_____ Freeway Corridor _____ Required Inspections: Footing _____ Final _____ Permit Fee: Permit Fee _____________ Miscellaneous ___________ Total ___________________ Comments: ________________________ ________________________ ________________________ ________________________ ________________________ ________________________ ________________________ Approved by:____________________________ Date:___________________________________ (REVISED JANUARY 2017) X X X X X $75 $75 17 February 2021 * Email kjenson@lakevillemn.gov after sign installation for final inspection. *Separate electrical permit may be required. W O R K S C O P E C O D E A L L O W A N C E S I T E P L A N CL.2 TP.1 CODE INFORMATION... ILLUMIUNATED PAN/CHAN LETTERS (QTY. 1) NON-ILLUMIUNATED PAN/CHAN LETTERS (QTY. 1) D/F TENANT PANEL (QTY. 1) N.T.S. 0.0 JOB #: 254761-R1 DATE: 01.19.2021 DESIGNER:J.D. Easton SALES REP:Jack Wellman PROJ MGR:Tyler Olson Airgas 21229 Hamburg Ave. Lakeville, MN. 55044DATE DATE LANDLORD APPROVAL CLIENT APPROVAL 02.09.21 00.00.00 00.00.00 00.00.00 00.00.00 00.00.00 00.00.00 00.00.00 00.00.00 00.00.00 JDE XX XX XX XX XX XX XX XX XX ADD BUILDING DIMENSIONS, SIGN HEIGHT ETC. CHANGE TO 1 SET ILLUM. & 1 SET NON. XXXX XXXX XXXX XXXX XXXX XXXX XXXX XXXX XXXX 1 2 3 4 5 6 7 8 9 10 SHEET NUMBER TP.1 CL.1 CL.1CL.2 --Drawing update required by permitting - the drawings are good enough for our actual refurbishment scope, but we need to plug boilerplate specs/cut sections in the permit review.CL.1 will be ILLUMINATED.CL.2 will NOT be illuminated.Permitting notes required:The drawings need to show overall length and height of building. scale from band measurementDimension of distance from grade to bottom of sign scale from band measurementWall sign section detail/type and color of materials and illumination, disconnect, power supply location copy paste standardWall sign method of attachment and wall material attach with tapcon screws through precastcompass showing North on current site plan, north is "up”Elevation called out North, South, West, etc CL.1 = East CL.2 = West LA188210 FRONT VIEW EXISTING EAST ELEVATION CONCEPTUAL VIEW OF NEW SIGN - EAST ELEVATION SCALE: 3/4" = 1'-0" FRONT ELEVATION - INSTALL EXISTING P/C/LTRS (QTY. 1)ILLUMINATED SQUARE FOOTAGE: 28.8 +/- CL.1 8’-0”3’-7 3/8”2’-6 1/2”+/-8 5/8” +/-EXISTING LETTER SETS EXISTING LETTER SETS EXISTING PAN/CHAN LETTERS TO BE INSTALLED AS SHOWN TO RIGHT. 143” CENTER SIGN IN THIS AREA CENTER SIGN IN THIS AREA58”143” CENTER SIGN IN THIS AREA CENTER SIGN IN THIS AREA58”1.0 JOB #: 254761-R1 DATE: 01.19.2021 DESIGNER:J.D. Easton SALES REP:Jack Wellman PROJ MGR:Tyler Olson Airgas 21229 Hamburg Ave. Lakeville, MN. 55044DATE DATE LANDLORD APPROVAL CLIENT APPROVAL SHEET NUMBER --Drawing update required by permitting - the drawings are good enough for our actual refurbishment scope, but we need to plug boilerplate specs/cut sections in the permit review.CL.1 will be ILLUMINATED.CL.2 will NOT be illuminated.Permitting notes required:The drawings need to show overall length and height of building. scale from band measurementDimension of distance from grade to bottom of sign scale from band measurementWall sign section detail/type and color of materials and illumination, disconnect, power supply location copy paste standardWall sign method of attachment and wall material attach with tapcon screws through precastcompass showing North on current site plan, north is "up”Elevation called out North, South, West, etc CL.1 = East CL.2 = West 18’-0” +/-18’-0” +/-180’ TOTAL BUILDING LENGTH 180’ TOTAL BUILDING LENGTH 150” +/-150” +/-PRECAST TAPCON SCREWS THRU PRE-CAST SEALTITE CONDUIT LOW VOLTAGE LED CABLE SECONDARY JUNCTION BOX LED POWER SUPPLY PRIMARY JUNCTION BOX (W/SERVICE DISCONNECT) PRIMARY SIGN CIRCUIT 1” TRIM CAP ACRYLIC FACE LED MODULE ALUMINUM LETTER RETURN DRAIN HOLE CHANNEL LETTER - TYP.ATTACHMENT ILLUMINATED 02.09.21 00.00.00 00.00.00 00.00.00 00.00.00 00.00.00 00.00.00 00.00.00 00.00.00 00.00.00 JDE XX XX XX XX XX XX XX XX XX ADD BUILDING DIMENSIONS, SIGN HEIGHT ETC. CHANGE TO 1 SET ILLUM. & 1 SET NON. XXXX XXXX XXXX XXXX XXXX XXXX XXXX XXXX XXXX 1 2 3 4 5 6 7 8 9 10 LA188210 TENANT PANEL GRAPHICS FOR D/F SIGN- (QTY. 1) SQUARE FOOTAGE: 28.8 +/- TP.1 FRONT VIEW SCALE: 3/4" = 1'-0" 7’-8 1/2” V.O.10 1/2”8 1/4”CONCEPTUAL VIEW OF NEW SIGN EXISTING CONDITIONS NEW VINYL GRAPHICS APPLIED TO EXISTING LEXAN FACES. GRAPHICS TO MATCH PMS 3155. 3.0 JOB #: 254761-R1 DATE: 01.19.2021 DESIGNER:J.D. Easton SALES REP:Jack Wellman PROJ MGR:Tyler Olson Airgas 21229 Hamburg Ave. Lakeville, MN. 55044DATE DATE LANDLORD APPROVAL CLIENT APPROVAL SHEET NUMBER 02.09.21 00.00.00 00.00.00 00.00.00 00.00.00 00.00.00 00.00.00 00.00.00 00.00.00 00.00.00 JDE XX XX XX XX XX XX XX XX XX ADD BUILDING DIMENSIONS, SIGN HEIGHT ETC. CHANGE TO 1 SET ILLUM. & 1 SET NON. XXXX XXXX XXXX XXXX XXXX XXXX XXXX XXXX XXXX 1 2 3 4 5 6 7 8 9 10 LA188210