HomeMy WebLinkAboutLA188210SIGN PERMIT & ELECTRONIC SIGN LICENSE APPLICATION
City of Lakeville - Planning Departrnent
24195 Holyoke Avenue - Lakeville, MN 55044
952. 985.4 42fr - www" nahevi"Ileryln . S*X
THE FOLLOWING INFORMATION MUST BE INCLUDED WITH YOUR APPLICATION:
tr Payment for amount of permit.
I Forfreestanding/monument/py.lon sigur -a siie plan with selback frorn propertyline dimensions and art
work with dimensions of sign, and engineered design for footings and foundation.
O For wall sign, art work with dimensions of sign and drawings of building fagade showing location of sign.
tr lf illuminated or if electrical services are needed, a separate elec-trical permit is required.
tr lf leased space, need to include a letter of approval from the property owner.
Applicant Signature:?lL7 tTL
BUSINE$S
INFORMATION
Contact - Iosh McDonnqll Day Phone
Email Address ioshuamcdonnell@airsas.com
5s044
# 952-747-0171
City Lakeville zip
21229 Ave
MN
PROPERry
ovvfitER city Eaflan . . state MN . zip
Contact Guidq Glipri Day Phone #
55121
651 -452-2700
11
Email Address seiori@grazzini.com
Grazzini Brothers &
SIGN
CONTRACTOR
AOOress 1711 Scheurinq Roa
Phone #804.325.1 1 3 1
Company Name Iones Sign Company Inc
City De Pere stut* WI zip 541 15
Email Address
Contact Kerri Sabol
permitting@i onessign. com
E Electronic
($100 Per sign Plus
completion of electronic sign
license, see Page 2)
{1000.4114)
EI Permanent
{$ZS per sign) (1000.4114)
tr Temporary
{$S0 per event, up to 60 days
per year. Max of one temp
sign displayed at a time.)
(1000.4114)
Temporary sign displayed dates:
START DATE
END DATE
Square feet 28.8 _
E Freestanding: Face Width- Height_
$+ ft- overall sjgn Height
-
Setbacks: Front Side
width- Height
Square Feet
E walt sign Height:3.61
Siqn Tvpe and Dime,nsionp
Display location
E Temporary
Sign
width I'
SIGH
DESCRIPTION
llluminated Sion:
EI lnternally illuminated
I Externally illuminated
tl "Not illuminated
Typg of Work:
tr New Sign
tr Replacement Sign
tr Alter Existing Sign
Chanseable, Copy;
E No Changeable Copy
tl Manuat Changeable Copy
I Electronic Changeable Copy
{Slectro*ic s€fi w-iH requir+ annu*l
licenss revisly & renerval, sse Page 2)
Applicant Printed Name: Kerri Sabol
a
LA188210
SIGN PERMIT & ELECTRONIC SIGN LICENSE APPLICATION Page 2
Electronic Display/Changeable Copy Sign License
By signing below you are certifying the electronic signage meets the following performance standards:
1.The display sign shall not change more than once every seven (7) seconds.
2.The display sign shall not include scrolling, flashing, animation, or other effects.
3.The display must be static and the transition from one static display to another must be
instantaneous without special effects.
4.The display image or message must be self-contained, without continuation in content to the next
image or message.
5.The brightness of the sign shall not exceed 5,000 NITS after sunrise and before sunset or 500
NITS after sunset and before sunrise each day.
6.The sign shall be equipped with an automatic dimmer control or other mechanism that
automatically controls the sign’s brightness to comply with this condition.
7.The display must be designed and equipped to freeze the device in one position if a malfunction of
the electronic display occurs.
8.The display must also be equipped with a means to immediately discontinue the display if it
malfunctions, and the sign owner must immediately stop the electronic display when notified by the
City that it is not complying with the stipulations of this section.
9.The sign shall comply with Chapter 23 of the Zoning Ordinance.
Signature_______________________________________ Date______________________________
Print Name______________________________________ Email ________________________________
EXPIRATION AND RENEWAL OF LICENSE:
•All licenses expire on December 31st of each year.
•License may be renewed only by making application as provided in Section 3-22-4 of the City Code.
•Application for renewal shall be made at least sixty (60) days before the expiration date.
•Each renewal license shall be issued for a maximum period of one (1) year.
•Annual license renewal fee is $50.00
Office Use Only
Sign Permit Type:
Permanent Sign _____
Temporary Sign _____
Electronic Sign _____
Work Type:
New _____
Addition _____
Repair _____
Demolish_____
Replace _____
Alter/Remodel _____
Move _____
Owner:
Public _____
Private _____
Zoning District:
Commercial _____
Industrial _____
Residential_____
Freeway Corridor _____
Required Inspections:
Footing _____
Final _____
Permit Fee:
Permit Fee _____________
Miscellaneous ___________
Total ___________________
Comments:
________________________
________________________
________________________
________________________
________________________
________________________
________________________
Approved by:____________________________
Date:___________________________________
(REVISED JANUARY 2017)
X
X
X
X
X
$75
$75 17 February 2021
* Email kjenson@lakevillemn.gov
after sign installation for final
inspection.
*Separate electrical permit may
be required.
W O R K S C O P E
C O D E A L L O W A N C E
S I T E P L A N
CL.2
TP.1
CODE INFORMATION...
ILLUMIUNATED PAN/CHAN LETTERS (QTY. 1)
NON-ILLUMIUNATED PAN/CHAN LETTERS (QTY. 1)
D/F TENANT PANEL (QTY. 1)
N.T.S.
0.0
JOB #: 254761-R1
DATE: 01.19.2021
DESIGNER:J.D. Easton
SALES REP:Jack Wellman
PROJ MGR:Tyler Olson
Airgas
21229 Hamburg Ave.
Lakeville, MN. 55044DATE
DATE
LANDLORD APPROVAL
CLIENT APPROVAL
02.09.21
00.00.00
00.00.00
00.00.00
00.00.00
00.00.00
00.00.00
00.00.00
00.00.00
00.00.00
JDE
XX
XX
XX
XX
XX
XX
XX
XX
XX
ADD BUILDING DIMENSIONS, SIGN HEIGHT ETC. CHANGE TO 1 SET ILLUM. & 1 SET NON.
XXXX
XXXX
XXXX
XXXX
XXXX
XXXX
XXXX
XXXX
XXXX
1
2
3
4
5
6
7
8
9
10
SHEET NUMBER
TP.1
CL.1
CL.1CL.2
--Drawing update required by permitting - the drawings are good enough for our actual refurbishment scope, but we need to plug boilerplate specs/cut sections in the permit review.CL.1 will be ILLUMINATED.CL.2 will NOT be illuminated.Permitting notes required:The drawings need to show overall length and height of building. scale from band measurementDimension of distance from grade to bottom of sign scale from band measurementWall sign section detail/type and color of materials and illumination, disconnect, power supply location copy paste standardWall sign method of attachment and wall material attach with tapcon screws through precastcompass showing North on current site plan, north is "up”Elevation called out North, South, West, etc CL.1 = East CL.2 = West
LA188210
FRONT VIEW
EXISTING EAST ELEVATION
CONCEPTUAL VIEW OF NEW SIGN - EAST ELEVATION
SCALE: 3/4" = 1'-0"
FRONT ELEVATION - INSTALL EXISTING P/C/LTRS (QTY. 1)ILLUMINATED
SQUARE FOOTAGE: 28.8 +/-
CL.1
8’-0”3’-7 3/8”2’-6 1/2”+/-8 5/8” +/-EXISTING LETTER SETS EXISTING LETTER SETS
EXISTING PAN/CHAN LETTERS
TO BE INSTALLED AS SHOWN TO
RIGHT.
143”
CENTER SIGN IN THIS AREA
CENTER SIGN IN THIS AREA58”143”
CENTER SIGN IN THIS AREA
CENTER SIGN IN THIS AREA58”1.0
JOB #: 254761-R1
DATE: 01.19.2021
DESIGNER:J.D. Easton
SALES REP:Jack Wellman
PROJ MGR:Tyler Olson
Airgas
21229 Hamburg Ave.
Lakeville, MN. 55044DATE
DATE
LANDLORD APPROVAL
CLIENT APPROVAL SHEET NUMBER
--Drawing update required by permitting - the drawings are good enough for our actual refurbishment scope, but we need to plug boilerplate specs/cut sections in the permit review.CL.1 will be ILLUMINATED.CL.2 will NOT be illuminated.Permitting notes required:The drawings need to show overall length and height of building. scale from band measurementDimension of distance from grade to bottom of sign scale from band measurementWall sign section detail/type and color of materials and illumination, disconnect, power supply location copy paste standardWall sign method of attachment and wall material attach with tapcon screws through precastcompass showing North on current site plan, north is "up”Elevation called out North, South, West, etc CL.1 = East CL.2 = West
18’-0” +/-18’-0” +/-180’ TOTAL
BUILDING LENGTH
180’ TOTAL
BUILDING LENGTH
150” +/-150” +/-PRECAST
TAPCON SCREWS THRU
PRE-CAST
SEALTITE CONDUIT
LOW VOLTAGE LED CABLE
SECONDARY JUNCTION BOX
LED POWER SUPPLY
PRIMARY JUNCTION BOX
(W/SERVICE DISCONNECT)
PRIMARY SIGN CIRCUIT
1” TRIM CAP
ACRYLIC FACE
LED MODULE
ALUMINUM LETTER
RETURN
DRAIN HOLE
CHANNEL LETTER - TYP.ATTACHMENT
ILLUMINATED
02.09.21
00.00.00
00.00.00
00.00.00
00.00.00
00.00.00
00.00.00
00.00.00
00.00.00
00.00.00
JDE
XX
XX
XX
XX
XX
XX
XX
XX
XX
ADD BUILDING DIMENSIONS, SIGN HEIGHT ETC. CHANGE TO 1 SET ILLUM. & 1 SET NON.
XXXX
XXXX
XXXX
XXXX
XXXX
XXXX
XXXX
XXXX
XXXX
1
2
3
4
5
6
7
8
9
10
LA188210
TENANT PANEL GRAPHICS FOR D/F SIGN- (QTY. 1)
SQUARE FOOTAGE: 28.8 +/-
TP.1
FRONT VIEW
SCALE: 3/4" = 1'-0"
7’-8 1/2”
V.O.10 1/2”8 1/4”CONCEPTUAL VIEW OF NEW SIGN EXISTING CONDITIONS
NEW VINYL GRAPHICS APPLIED
TO EXISTING LEXAN FACES.
GRAPHICS TO MATCH PMS 3155.
3.0
JOB #: 254761-R1
DATE: 01.19.2021
DESIGNER:J.D. Easton
SALES REP:Jack Wellman
PROJ MGR:Tyler Olson
Airgas
21229 Hamburg Ave.
Lakeville, MN. 55044DATE
DATE
LANDLORD APPROVAL
CLIENT APPROVAL SHEET NUMBER
02.09.21
00.00.00
00.00.00
00.00.00
00.00.00
00.00.00
00.00.00
00.00.00
00.00.00
00.00.00
JDE
XX
XX
XX
XX
XX
XX
XX
XX
XX
ADD BUILDING DIMENSIONS, SIGN HEIGHT ETC. CHANGE TO 1 SET ILLUM. & 1 SET NON.
XXXX
XXXX
XXXX
XXXX
XXXX
XXXX
XXXX
XXXX
XXXX
1
2
3
4
5
6
7
8
9
10
LA188210