Loading...
HomeMy WebLinkAbout20528 Geyser Court SurveyA. 1/26/21: Client*DROP GARAGE TOP OF BLOCK 1.34'*PHONE: 952.890.6044 www.jrhinc.com PLANNERS / ENGINEERS / SURVEYORSDRAWN BYDATEREVISIONSCAD FILEPROJECT NO.SHEET 1 OF 12999 WEST C.R. 42, SUITE 100, BURNSVILLE, MN 55306 CERTIFICATE OF SURVEY FOR SHP1/22/2021410108.dwg410108Lot 11, Block 1, CEDAR CROSSINGS 2ND ADDITION, Dakota County, Minnesota 1. Bearings are based on the recorded plat.2. Building dimensions shown are for horizontal and vertical placement ofstructure only. See architectural plans for building and foundationdimensions.3. No specific soils investigation has been completed on this lot by JamesR. Hill, Inc. the suitability of soils to support the specific house proposedis not the responsibility of James R. Hill, Inc. or the surveyor.4. No specific title search for existence or non-existence of recorded orun-recorded easements has been conducted by the surveyor as a partof this survey. Only easements per the recorded plat are shown.5. Proposed grades shown were taken from the grading &/ordevelopment plan prepared by James R. Hill, Inc.6. Grading plan date/revision date: July 13, 20187. Plan No. 3030-C 'CAMERON'NOTESLot = 9,606 sq. ft.House/Garage = 2,469 sq. ft.Porch = 114 sq. ft.Driveway = 693 sq. ft.Sidewalk = 71 sq. ft.Total Impervious = 3,347 sq. ft. or 34.84% of lotHARD COVER CALCULATIONSProposedGarage Floor @ Front = 972.2Garage Top of Foundation = 972.6House Top of Foundation = 973.94Lowest Floor = 970.74Lot 11, Block 1, CEDAR CROSSINGS 2ND ADDITION, Dakota County, MinnesotaPROPERTY DESCRIPTION20528 Geyser Court, Lakeville, MinnesotaPROPERTY ADDRESSI hereby certify that this survey, plan or report was prepared by me or undermy direct supervision and that I am a duly Licensed Land Surveyor under thelaws of the State of Minnesota. That this survey does not purport to show allimprovements, easements or encroachments, to the property except asshown thereon.Signed this 22nd day of January, 2021Marcus F. Hampton, MN L.S. No. 47481SURVEYOR'S CERTIFICATEFLOOR ELEVATIONSTop nut of hydrant located at Lots 3 and 4, Block 1 = 971.97BENCHMARKDenotes set spikeDenotes set iron monumentDenotes found iron monumentDenotes found scribed "x"Denotes set hubDenotes proposed drainageDenotes top of curbDenotes existing elevationDenotes proposed elevationZoning = RST-2FY - 20' House, 25' GarageSY - 7' Interior, 20' CornerRY - 30'SY Buffer - 30'RY Buffer - 50'*Draintile connection required.ENGINEERING REVIEWEDDate:__________________02/08/2021lvlasatyThe curb box, drain tile cleanout, and catchbasin(if applicable) must be inspected andaccepted before As-Built escrow monies willbe released. All structures must be flushwith the sod. This will be scheduled with thelandscape inspection.EROSION CONTROL MUST BE INSTALLED BEFORE EXCAVATION*Maintain 6" between bottom of siding and sod.*No structures in easements.