Loading...
HomeMy WebLinkAboutLA187775 - 7726 204th St W Permit PackRESIDENTIAL BUILDING PERMIT APPLICATION CITY OF LAKEVILLE BUILDING INSPECTIONS DEPARTMENT 20195 HOLYOKE AVENUE LAKEVILLE, MN 55044 952-985-4440 Office Use Only __________________ Permit Number ___________________ Received By ___________________ Date Received ___________________ Fee Total SITE ADDRESS: MAILING ADDRESS: CITY: STATE: ZIP: JOB DESCRIPTION:__________________________________ MASTER PLAN: (Number or Address)____________________ LIST OTHER STRUCTURES ON PROPERTY:_______________________________________________________________ ESTIMATED VALUATION: PROPOSED START DATE: END DATE: (New Residential Only): LEGAL DESCRIPTION: LOT: _____ BLOCK: _____ SUBDIVISION: APPLICANT IS: RESIDENT OWNER CONTRACTOR EMAIL NEW MODEL HOME: YES NO (IF YES – ADMINISTRATIVE PERMIT REQUIRED) PLEASE FILL OUT THE FOLLOWING COMPLETELY (All Contractor information must be as listed on State License) RESIDENT OWNER NAME:_______________________________________________________________________________ HOME PHONE #:_____________________________ CELL PHONE:___________________________ GENERAL CONTRACTOR Homeowner Contractor CONTRACTOR:_______________________________________________________________________ LICENSE #:BC______________ LEAD CERTIFICATE#_______________ (PRE 1978 STRUCTURE) OFFICE PHONE #:_____________________________ CELL PHONE:___________________________ ADDRESS:____________________________ CITY:________________ ST:______ ZIP:____________ PLUMBING WORK Homeowner Contractor CONTRACTOR:__________________________________________LICENSE #: PM______________ OFFICE PHONE #:_____________________________ CELL PHONE:___________________________ ADDRESS:____________________________ CITY:________________ ST:______ ZIP:____________ MECHANICAL WORK Homeowner Contractor CONTRACTOR:________________________________________ _______________________________ OFFICE PHONE #:_____________________________ CELL PHONE:___________________________ ADDRESS:____________________________ CITY:________________ ST:______ ZIP:____________ BOND #:_______________________________________ EXPIRATION DATE____________________ SEWER/WATER CONTRACTOR New Construction Only NAME:________________________________________________ ______________________________ HOME PHONE _____________________________ CELL PHONE:______________________________ BOND #:_______________________________________ EXPIRATION DATE____________________ INTEREST EARNINGS ON THE ESCROW ACCOUNTS, IF ANY, ARE RETAINED BY THE CITY TO OFFSET THE ADMINISTRATIVE COSTS ASSOCIATED WITH PROCESSING THE ESCROW APPLICATION AND REFUND. I HEREBY APPLY FOR A BUILDING PERMIT AND I ACKNOWLEDGE THAT THE INFORMATION ABOVE IS COMPLETE AND ACCURATE; THAT THE WORK WILL BE IN CONFORMANCE WITH THE ORDINANCES AND CODES OF THE CITY AND WITH THE STATE BUILDING CODE, THAT I UNDERSTAND THIS IS NOT A PERMIT AND WORK IS NOT TO START WITHOUT A PERMIT AND THAT THE WORK WILL BE IN ACCORDANCE WITH THE APPROVED PLAN. NAME OF APPLICANT (Please Print)DATE APPLICANT’S SIGNATURE: www.lakevillemn.gov 1/20/21 DM RESIDENTIAL BUILDING PERMIT APPLICATION PAGE 2 OFFICE USE ONLY BUILDING PERMIT TYPE REQUIRED INSPECTIONS SINGLE FAMILY DWELLING BUILDING DUPLEX AS BUILT TOWNHOUSE UNITS BUILDING FINAL DETACHED TOWN HOUSE UNIT DECK FOOTING CONDO FIREPLACE ACESSORY BUILDING FOOTING REROOF FOUNDATION RESIDE FRAMING PORCH FRAMING GARAGES INSULATION RES ADDN/REPAIR/RMDL DECK PORCH GARAGES LATH LOWER LEVEL FINISH LOWER LEVEL FINAL ADDITION OTHER FOUNDATION ONLY PORCH FOOTING MISCELLANEOUS POURED WALL DEMO SEPTIC TANK REMOVAL MOVED SITE MECHANICAL CITY BUILDING VALUATION: $AIR TEST FINAL BUILDING PERMIT FEES ROUGH-IN $PERMIT FEE PLUMBING $PLAN CHECK FINAL $SURCHARGE ROUGH-IN $METRO SAC METER SIZE $CITY WATER HOOKUP UNIT PRESSURE REDUCING VALVE $CITY SEWER HOOKUP UNIT SEWER/WATER $LANDSCAPE ESCROW SEWER/WATER $TREE ESCROW FINAL $MISC ESCROW STREET DRAINTILE $PLUMBING BUILDING INFORMATION $MECHANICAL TYPE OF CONSTRUCTION $SEWER WATER ZONING $OTHER CODE EDITION $TOTAL FIRE SUPPRESSION SYSTEM OCCUPANCY GROUP APPROVED BY: BUILDING INSPECTOR: Date: PLUMBING/MECHANICAL INSPECTOR: Date: COMMENTS: 20195 Holyoke Avenue, Lakeville, MN 55044 952-985-4400  952-985-4499 fax www.lakevillemn.gov Sewer & Water Tie Card Address:________________________________________ Contractor:______________________________________ Permit Number:__________________________________ Final Date:________________ Street Drain-Tile:______ Size of Water Service: 1” Comments: AIRTEST SANITARY OVER 20’/2 FITTINGS THIS CARD MUST BE COMPLETED AND ON-SITE AT TIME OF SEWER & WATER INSPECTION 353Drawing No.Sheet Title: ELEVATIONS 1 OF 7 Drawn By: Lot:Block:07 02 Date: Drawn By: JM 10/26/2020 Builder :ONE TEN TEN HOMES - BROOKE #OTT124 Project:JULIA AND THOMAS RUBY- 7726 204TH ST. W Address:7726 204TH ST. W-ASPEN GROVE 2ND 1/4"=1'-0" Scale: Sheet Title:CUST M REVISIONS:SQUARE FT.UPPER: 1713MAIN: 1464LOWER: 1171TOTAL: 4348PLATE HEIGHTSUPPER: 8'-1 1/8"MAIN: 9'-1-1/8"LOWER: 8'-4"1/19/2020Concept Approval ONLYSubject to Field InspectionInspectorDate2020MN BldgCode01/25/2021dmathews Drawing No.Sheet Title: ELEVATIONS 1 OF 7 Drawn By: Lot:Block:07 02 Date: Drawn By: JM 10/26/2020 Builder :ONE TEN TEN HOMES - BROOKE #OTT124 Project:JULIA AND THOMAS RUBY- 7726 204TH ST. W Address:7726 204TH ST. W-ASPEN GROVE 2ND 1/4"=1'-0" Scale: Sheet Title:CUST M REVISIONS:SQUARE FT.UPPER: 1713MAIN: 1464LOWER: 1171TOTAL: 4348PLATE HEIGHTSUPPER: 8'-1 1/8"MAIN: 9'-1-1/8"LOWER: 8'-4"1/19/2020Secure door closed until deck isconstructed with a separate permit. 1112119Drawing No.Sheet Title: BASEMENT FL. PLAN 3 OF 7 Drawn By: Lot:Block:07 02 Date: Drawn By: JM 10/26/2020 Builder :ONE TEN TEN HOMES - BROOKE #OTT124 Project:JULIA AND THOMAS RUBY- 7726 204TH ST. W Address:7726 204TH ST. W-ASPEN GROVE 2ND 1/4"=1'-0" Scale: Sheet Title:CUST M REVISIONS:SQUARE FT.UPPER: 1713MAIN: 1464LOWER: 1171TOTAL: 4348PLATE HEIGHTSUPPER: 8'-1 1/8"MAIN: 9'-1-1/8"LOWER: 8'-4"1/19/2020UFER Ground-Provide 20' Rebar in footing and stubup near electrical service panel.FAN DN 3R8513141414233108Drawing No.Sheet Title: FIRST FL. PLAN 4 OF 7 Drawn By: Lot:Block:07 02 Date: Drawn By: JM 10/26/2020 Builder :ONE TEN TEN HOMES - BROOKE #OTT124 Project:JULIA AND THOMAS RUBY- 7726 204TH ST. W Address:7726 204TH ST. W-ASPEN GROVE 2ND 1/4"=1'-0" Scale: Sheet Title:CUST M REVISIONS:SQUARE FT.UPPER: 1713MAIN: 1464LOWER: 1171TOTAL: 4348PLATE HEIGHTSUPPER: 8'-1 1/8"MAIN: 9'-1-1/8"LOWER: 8'-4"1/19/2020BWPsAboveTemper ifwithin 36" oflanding floorVerify loads with girdertruss specs, may requireremoval of top plates atbearing due to crushing.FAN 48866886122753Drawing No.Sheet Title: FIRST FL. PLAN 5 OF 7 Drawn By: Lot:Block:07 02 Date: Drawn By: JM 10/26/2020 Builder :ONE TEN TEN HOMES - BROOKE #OTT124 Project:JULIA AND THOMAS RUBY- 7726 204TH ST. W Address:7726 204TH ST. W-ASPEN GROVE 2ND 1/4"=1'-0" Scale: Sheet Title:CUST M REVISIONS:SQUARE FT.UPPER: 1713MAIN: 1464LOWER: 1171TOTAL: 4348PLATE HEIGHTSUPPER: 8'-1 1/8"MAIN: 9'-1-1/8"LOWER: 8'-4"1/19/2020FANFANFANFANB.W.Ps neededon front elevationB.W.Ps neededon front elevation 6" 6" 6" 8'-118"9'-118"8'-2" Drawing No.Sheet Title: DETAILS 6 OF 7 Drawn By: Lot:Block:07 02 Date: Drawn By: JM 10/26/2020 Builder :ONE TEN TEN HOMES - BROOKE #OTT124 Project:JULIA AND THOMAS RUBY- 7726 204TH ST. W Address:7726 204TH ST. W-ASPEN GROVE 2ND 1/4"=1'-0" Scale: Sheet Title:CUST M BRACED WALL PANEL CONNECTIONTO PERPENDICULARRAFTERS OR TRUSSESBRACED WALL PANEL CONNECTIONWHEN PARALLEL TO FLOOR/CEILING FRAMINGCROSS SECTIONCROSS SECTION ON BRACED WALL PANELS IN WALL SECTIONOUTSIDE CORNERPOST BEAM CONNECTIONSPORTAL FRAME W/ HOLD-DOWNS (PFH)1/4" = 1'-0" R602.10.6.2CONT. SHEATHED PORTAL FRAME (CS-PF)1/4" = 1'-0" R602.10.6.4@ FLOOR TRUSS LOCATIONS1/4" = 1'-0" R602.10.6.2PORTAL FRAME W/ HOLD-DOWNSDrawing No.Sheet Title: DETAILS 7 OF 7 Drawn By: Lot:Block:07 02 Date: Drawn By: JM 10/26/2020 Builder :ONE TEN TEN HOMES - BROOKE #OTT124 Project:JULIA AND THOMAS RUBY- 7726 204TH ST. W Address:7726 204TH ST. W-ASPEN GROVE 2ND 1/4"=1'-0" Scale: Sheet Title:CUST M Upper Level Member Name Results Current Solution Comments Owner's Suite Window Passed 2 piece(s) 1 3/4" x 9 1/2" 1.55E TimberStrand® LSL Owner's Bath Window Passed 2 piece(s) 2 x 10 Spruce-Pine-Fir No. 1 / No. 2 Bedroom #4 Window Passed 2 piece(s) 2 x 10 Spruce-Pine-Fir No. 1 / No. 2 Bedroom #4 WIC Window Passed 2 piece(s) 2 x 10 Spruce-Pine-Fir No. 1 / No. 2 Bedroom #3 Window Passed 2 piece(s) 2 x 10 Spruce-Pine-Fir No. 1 / No. 2 Bedroom #2 Window Passed 2 piece(s) 2 x 10 Spruce-Pine-Fir No. 1 / No. 2 Main Level Member Name Results Current Solution Comments Mudroom Bump Out Header Passed 2 piece(s) 2 x 10 Spruce-Pine-Fir No. 1 / No. 2 Dining Room Window Rear Passed 2 piece(s) 2 x 10 Spruce-Pine-Fir No. 1 / No. 2 Great Room Window Rear Passed 3 piece(s) 1 3/4" x 9 1/2" 1.55E TimberStrand® LSL Office Window Passed 2 piece(s) 2 x 10 Spruce-Pine-Fir No. 1 / No. 2 Foyer Entry Door Passed 3 piece(s) 2 x 10 Spruce-Pine-Fir No. 1 / No. 2 Drop Beam over Front Porch (H)Passed 2 piece(s) 1 3/4" x 9 1/2" 2.0E Microllam® LVL Drop Beam over Front Porch (V)Passed 2 piece(s) 1 3/4" x 9 1/2" 1.55E TimberStrand® LSL 8' Garage Door Opening Passed 2 piece(s) 2 x 12 Spruce-Pine-Fir No. 1 / No. 2 16' Garage Door Opening Passed 2 piece(s) 1 3/4" x 11 7/8" 1.55E TimberStrand® LSL Flush Beam over Stairs/Great Room (H) Passed 3 piece(s) 1 3/4" x 16" 2.0E Microllam® LVL Mudroom Entry Door Passed 3 piece(s) 1 3/4" x 9 1/2" 1.55E TimberStrand® LSL Flush Garage Middle (V)Passed 3 piece(s) 1 3/4" x 20" 2.0E Microllam® LVL Flush Garage End (V)Passed 2 piece(s) 2 x 10 Spruce-Pine-Fir No. 1 / No. 2 Lower Level Member Name Results Current Solution Comments Family Room Window Passed 3 piece(s) 1 3/4" x 9 1/2" 1.55E TimberStrand® LSL Games Room Window Rear Passed 3 piece(s) 2 x 10 Spruce-Pine-Fir No. 1 / No. 2 Bedroom #4 Window Passed 2 piece(s) 1 3/4" x 9 1/2" 1.55E TimberStrand® LSL Hallway Opening Passed 2 piece(s) 2 x 10 Spruce-Pine-Fir No. 1 / No. 2 Flush Game (H)Passed 3 piece(s) 1 3/4" x 14" 2.0E Microllam® LVL 7726 204th Street W, Lakeville, MN JOB SUMMARY REPORT ForteWEB Software Operator Job Notes 12/16/2020 6:09:37 PM UTCJeffrey Doty, Design Supervisor Lyman Lumber Company (952) 470-4866 jeff_doty@lymanlumber.com ForteWEB v3.1 File Name: 7726 204th Street W, Lakeville, MN Topaz - The Brooke 7726 204th Street W, Lakeville, MN 12/16/2020; #24535 Page 1 / 26 Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (lbs)4953 @ 1 1/2"7613 (3.00")Passed (65%)--1.0 D + 1.0 S (All Spans) Shear (lbs)3739 @ 1' 1/2"7902 Passed (47%)1.15 1.0 D + 1.0 S (All Spans) Moment (Ft-lbs)9915 @ 4' 3"11985 Passed (83%)1.15 1.0 D + 1.0 S (All Spans) Live Load Defl. (in)0.226 @ 4' 3"0.275 Passed (L/439)--1.0 D + 1.0 S (All Spans) Total Load Defl. (in)0.358 @ 4' 3"0.412 Passed (L/277)--1.0 D + 1.0 S (All Spans) System : Wall Member Type : Header Building Use : Residential Building Code : IBC 2018 Design Methodology : ASD •Deflection criteria: LL (L/360) and TL (L/240). •Allowed moment does not reflect the adjustment for the beam stability factor. Bearing Length Loads to Supports (lbs) Supports Total Available Required Dead Snow Total Accessories 1 - Trimmer - SPF 3.00"3.00"1.95"1829 3124 4953 None 2 - Trimmer - SPF 3.00"3.00"1.95"1829 3124 4953 None •Maximum allowable bracing intervals based on applied load. Lateral Bracing Bracing Intervals Comments Top Edge (Lu)7' 4" o/c Bottom Edge (Lu)8' 6" o/c Dead Snow Vertical Loads Location (Side)Tributary Width (0.90)(1.15)Comments 0 - Self Weight (PLF)0 to 8' 6"N/A 10.4 -- 1 - Uniform (PSF)0 to 8' 6"21'20.0 35.0 Snow - Main Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/document-library. The product application, input design loads, dimensions and support information have been provided by Custom; plan dated 10/26/2020. Weyerhaeuser Notes All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal. MEMBER REPORT PASSED Upper Level, Owner's Suite Window 2 piece(s) 1 3/4" x 9 1/2" 1.55E TimberStrand® LSL ForteWEB Software Operator Job Notes 12/16/2020 6:09:37 PM UTCJeffrey Doty, Design Supervisor Lyman Lumber Company (952) 470-4866 jeff_doty@lymanlumber.com ForteWEB v3.1, Engine: V8.1.5.1, Data: V8.0.1.0 File Name: 7726 204th Street W, Lakeville, MN Topaz - The Brooke 7726 204th Street W, Lakeville, MN 12/16/2020; #24535 Page 2 / 26 Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (lbs)1352 @ 0 1913 (1.50")Passed (71%)--1.0 D + 1.0 S (All Spans) Shear (lbs)607 @ 10 3/4"2872 Passed (21%)1.15 1.0 D + 1.0 S (All Spans) Moment (Ft-lbs)1099 @ 1' 7 1/2"3946 Passed (28%)1.15 1.0 D + 1.0 S (All Spans) Live Load Defl. (in)0.005 @ 1' 7 1/2"0.108 Passed (L/999+)--1.0 D + 1.0 S (All Spans) Total Load Defl. (in)0.008 @ 1' 7 1/2"0.162 Passed (L/999+)--1.0 D + 1.0 S (All Spans) System : Wall Member Type : Header Building Use : Residential Building Code : IBC 2018 Design Methodology : ASD •Deflection criteria: LL (L/360) and TL (L/240). •Allowed moment does not reflect the adjustment for the beam stability factor. •Applicable calculations are based on NDS. Bearing Length Loads to Supports (lbs) Supports Total Available Required Dead Snow Total Accessories 1 - Trimmer - SPF 1.50"1.50"1.50"499 853 1352 None 2 - Trimmer - SPF 1.50"1.50"1.50"499 853 1352 None •Maximum allowable bracing intervals based on applied load. Lateral Bracing Bracing Intervals Comments Top Edge (Lu)3' 3" o/c Bottom Edge (Lu)3' 3" o/c Dead Snow Vertical Loads Location (Side)Tributary Width (0.90)(1.15)Comments 0 - Self Weight (PLF)0 to 3' 3"N/A 7.0 -- 1 - Uniform (PSF)0 to 3' 3"15'20.0 35.0 Snow - Main Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/document-library. The product application, input design loads, dimensions and support information have been provided by Custom; plan dated 10/26/2020. Weyerhaeuser Notes All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal. MEMBER REPORT PASSED Upper Level, Owner's Bath Window 2 piece(s) 2 x 10 Spruce-Pine-Fir No. 1 / No. 2 ForteWEB Software Operator Job Notes 12/16/2020 6:09:37 PM UTCJeffrey Doty, Design Supervisor Lyman Lumber Company (952) 470-4866 jeff_doty@lymanlumber.com ForteWEB v3.1, Engine: V8.1.5.1, Data: V8.0.1.0 File Name: 7726 204th Street W, Lakeville, MN Topaz - The Brooke 7726 204th Street W, Lakeville, MN 12/16/2020; #24535 Page 3 / 26 Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (lbs)1548 @ 0 1913 (1.50")Passed (81%)--1.0 D + 1.0 S (Alt Spans) Shear (lbs)1265 @ 4' 4 3/4"2872 Passed (44%)1.15 1.0 D + 1.0 S (All Spans) Moment (Ft-lbs)-1655 @ 3' 4 1/2"3946 Passed (42%)1.15 1.0 D + 1.0 S (All Spans) Live Load Defl. (in)0.004 @ 1' 6 13/16"0.112 Passed (L/999+)--1.0 D + 1.0 S (Alt Spans) Total Load Defl. (in)0.006 @ 1' 6 1/2"0.169 Passed (L/999+)--1.0 D + 1.0 S (Alt Spans) System : Wall Member Type : Header Building Use : Residential Building Code : IBC 2018 Design Methodology : ASD •Deflection criteria: LL (L/360) and TL (L/240). •Allowed moment does not reflect the adjustment for the beam stability factor. •Applicable calculations are based on NDS. Bearing Length Loads to Supports (lbs) Supports Total Available Required Dead Snow Total Accessories 1 - Trimmer - SPF 1.50"1.50"1.50"540 1008 1548 None 2 - Trimmer - SPF 6.00"6.00"3.84"1802 3101 4903 None 3 - Trimmer - SPF 1.50"1.50"1.50"540 1008 1548 None •Maximum allowable bracing intervals based on applied load. Lateral Bracing Bracing Intervals Comments Top Edge (Lu)6' 9" o/c Bottom Edge (Lu)6' 9" o/c Dead Snow Vertical Loads Location (Side)Tributary Width (0.90)(1.15)Comments 0 - Self Weight (PLF)0 to 6' 9"N/A 7.0 -- 1 - Uniform (PSF)0 to 6' 9"21'20.0 35.0 Snow - Main Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/document-library. The product application, input design loads, dimensions and support information have been provided by Custom; plan dated 10/26/2020. Weyerhaeuser Notes All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal. MEMBER REPORT PASSED Upper Level, Bedroom #4 Window 2 piece(s) 2 x 10 Spruce-Pine-Fir No. 1 / No. 2 ForteWEB Software Operator Job Notes 12/16/2020 6:09:37 PM UTCJeffrey Doty, Design Supervisor Lyman Lumber Company (952) 470-4866 jeff_doty@lymanlumber.com ForteWEB v3.1, Engine: V8.1.5.1, Data: V8.0.1.0 File Name: 7726 204th Street W, Lakeville, MN Topaz - The Brooke 7726 204th Street W, Lakeville, MN 12/16/2020; #24535 Page 4 / 26 Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (lbs)1598 @ 0 1913 (1.50")Passed (84%)--1.0 D + 1.0 S (All Spans) Shear (lbs)557 @ 10 3/4"2872 Passed (19%)1.15 1.0 D + 1.0 S (All Spans) Moment (Ft-lbs)1098 @ 1' 4 1/2"3946 Passed (28%)1.15 1.0 D + 1.0 S (All Spans) Live Load Defl. (in)0.003 @ 1' 4 1/2"0.092 Passed (L/999+)--1.0 D + 1.0 S (All Spans) Total Load Defl. (in)0.005 @ 1' 4 1/2"0.138 Passed (L/999+)--1.0 D + 1.0 S (All Spans) System : Wall Member Type : Header Building Use : Residential Building Code : IBC 2018 Design Methodology : ASD •Deflection criteria: LL (L/360) and TL (L/240). •Allowed moment does not reflect the adjustment for the beam stability factor. •Applicable calculations are based on NDS. Bearing Length Loads to Supports (lbs) Supports Total Available Required Dead Snow Total Accessories 1 - Trimmer - SPF 1.50"1.50"1.50"587 1011 1598 None 2 - Trimmer - SPF 1.50"1.50"1.50"587 1011 1598 None •Maximum allowable bracing intervals based on applied load. Lateral Bracing Bracing Intervals Comments Top Edge (Lu)2' 9" o/c Bottom Edge (Lu)2' 9" o/c Dead Snow Vertical Loads Location (Side)Tributary Width (0.90)(1.15)Comments 0 - Self Weight (PLF)0 to 2' 9"N/A 7.0 -- 1 - Uniform (PSF)0 to 2' 9"21'20.0 35.0 Snow - Main Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/document-library. The product application, input design loads, dimensions and support information have been provided by Custom; plan dated 10/26/2020. Weyerhaeuser Notes All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal. MEMBER REPORT PASSED Upper Level, Bedroom #4 WIC Window 2 piece(s) 2 x 10 Spruce-Pine-Fir No. 1 / No. 2 ForteWEB Software Operator Job Notes 12/16/2020 6:09:37 PM UTCJeffrey Doty, Design Supervisor Lyman Lumber Company (952) 470-4866 jeff_doty@lymanlumber.com ForteWEB v3.1, Engine: V8.1.5.1, Data: V8.0.1.0 File Name: 7726 204th Street W, Lakeville, MN Topaz - The Brooke 7726 204th Street W, Lakeville, MN 12/16/2020; #24535 Page 5 / 26 Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (lbs)307 @ 0 1913 (1.50")Passed (16%)--1.0 D + 1.0 S (Alt Spans) Shear (lbs)214 @ 1' 10 1/4"2872 Passed (7%)1.15 1.0 D + 1.0 S (Adj Spans) Moment (Ft-lbs)-291 @ 6' 4 1/2"3946 Passed (7%)1.15 1.0 D + 1.0 S (Adj Spans) Live Load Defl. (in)0.000 @ 4' 7 11/16"0.117 Passed (L/999+)--1.0 D + 1.0 S (Alt Spans) Total Load Defl. (in)0.001 @ 11' 6 1/2"0.144 Passed (L/999+)--1.0 D + 1.0 S (Alt Spans) System : Wall Member Type : Header Building Use : Residential Building Code : IBC 2018 Design Methodology : ASD •Deflection criteria: LL (L/360) and TL (L/240). •Allowed moment does not reflect the adjustment for the beam stability factor. •Applicable calculations are based on NDS. Bearing Length Loads to Supports (lbs) Supports Total Available Required Dead Snow Total Accessories 1 - Trimmer - SPF 1.50"1.50"1.50"180 126 306 None 2 - Trimmer - SPF 6.00"6.00"1.50"593 388 981 None 3 - Trimmer - SPF 6.00"6.00"1.50"584 391 975 None 4 - Trimmer - SPF 6.00"6.00"1.50"593 388 981 None 5 - Trimmer - SPF 1.50"1.50"1.50"180 126 306 None •Maximum allowable bracing intervals based on applied load. Lateral Bracing Bracing Intervals Comments Top Edge (Lu)12' 9" o/c Bottom Edge (Lu)12' 9" o/c Dead Snow Vertical Loads Location (Side)Tributary Width (0.90)(1.15)Comments 0 - Self Weight (PLF)0 to 12' 9"N/A 7.0 -- 1 - Uniform (PSF)0 to 12' 9"3'20.0 35.0 Snow - Main 2 - Uniform (PLF)0 to 12' 9"N/A 100.0 -Wall - Gable Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/document-library. The product application, input design loads, dimensions and support information have been provided by Custom; plan dated 10/26/2020. Weyerhaeuser Notes All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal. MEMBER REPORT PASSED Upper Level, Bedroom #3 Window 2 piece(s) 2 x 10 Spruce-Pine-Fir No. 1 / No. 2 ForteWEB Software Operator Job Notes 12/16/2020 6:09:37 PM UTCJeffrey Doty, Design Supervisor Lyman Lumber Company (952) 470-4866 jeff_doty@lymanlumber.com ForteWEB v3.1, Engine: V8.1.5.1, Data: V8.0.1.0 File Name: 7726 204th Street W, Lakeville, MN Topaz - The Brooke 7726 204th Street W, Lakeville, MN 12/16/2020; #24535 Page 6 / 26 Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (lbs)2288 @ 1 1/2"3825 (3.00")Passed (60%)--1.0 D + 1.0 S (All Spans) Shear (lbs)1439 @ 1' 1/4"2872 Passed (50%)1.15 1.0 D + 1.0 S (All Spans) Moment (Ft-lbs)2867 @ 2' 9"3946 Passed (73%)1.15 1.0 D + 1.0 S (All Spans) Live Load Defl. (in)0.032 @ 2' 9"0.175 Passed (L/999+)--1.0 D + 1.0 S (All Spans) Total Load Defl. (in)0.051 @ 2' 9"0.262 Passed (L/999+)--1.0 D + 1.0 S (All Spans) System : Wall Member Type : Header Building Use : Residential Building Code : IBC 2018 Design Methodology : ASD •Deflection criteria: LL (L/360) and TL (L/240). •Allowed moment does not reflect the adjustment for the beam stability factor. •Applicable calculations are based on NDS. Bearing Length Loads to Supports (lbs) Supports Total Available Required Dead Snow Total Accessories 1 - Trimmer - SPF 3.00"3.00"1.79"844 1444 2288 None 2 - Trimmer - SPF 3.00"3.00"1.79"844 1444 2288 None •Maximum allowable bracing intervals based on applied load. Lateral Bracing Bracing Intervals Comments Top Edge (Lu)5' 6" o/c Bottom Edge (Lu)5' 6" o/c Dead Snow Vertical Loads Location (Side)Tributary Width (0.90)(1.15)Comments 0 - Self Weight (PLF)0 to 5' 6"N/A 7.0 -- 1 - Uniform (PSF)0 to 5' 6"15'20.0 35.0 Snow - Main Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/document-library. The product application, input design loads, dimensions and support information have been provided by Custom; plan dated 10/26/2020. Weyerhaeuser Notes All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal. MEMBER REPORT PASSED Upper Level, Bedroom #2 Window 2 piece(s) 2 x 10 Spruce-Pine-Fir No. 1 / No. 2 ForteWEB Software Operator Job Notes 12/16/2020 6:09:37 PM UTCJeffrey Doty, Design Supervisor Lyman Lumber Company (952) 470-4866 jeff_doty@lymanlumber.com ForteWEB v3.1, Engine: V8.1.5.1, Data: V8.0.1.0 File Name: 7726 204th Street W, Lakeville, MN Topaz - The Brooke 7726 204th Street W, Lakeville, MN 12/16/2020; #24535 Page 7 / 26 Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (lbs)1483 @ 0 1913 (1.50")Passed (78%)--1.0 D + 0.75 L + 0.75 S (All Spans) Shear (lbs)545 @ 10 3/4"2872 Passed (19%)1.15 1.0 D + 0.75 L + 0.75 S (All Spans) Moment (Ft-lbs)1051 @ 1' 5"3946 Passed (27%)1.15 1.0 D + 0.75 L + 0.75 S (All Spans) Live Load Defl. (in)0.003 @ 1' 5"0.094 Passed (L/999+)--1.0 D + 0.75 L + 0.75 S (All Spans) Total Load Defl. (in)0.005 @ 1' 5"0.142 Passed (L/999+)--1.0 D + 0.75 L + 0.75 S (All Spans) System : Wall Member Type : Header Building Use : Residential Building Code : IBC 2018 Design Methodology : ASD •Deflection criteria: LL (L/360) and TL (L/240). •Allowed moment does not reflect the adjustment for the beam stability factor. •Applicable calculations are based on NDS. Bearing Length Loads to Supports (lbs) Supports Total Available Required Dead Floor Live Snow Total Accessories 1 - Trimmer - SPF 1.50"1.50"1.50"655 510 595 1760 None 2 - Trimmer - SPF 1.50"1.50"1.50"655 510 595 1760 None •Maximum allowable bracing intervals based on applied load. Lateral Bracing Bracing Intervals Comments Top Edge (Lu)2' 10" o/c Bottom Edge (Lu)2' 10" o/c Dead Floor Live Snow Vertical Loads Location (Side)Tributary Width (0.90)(1.00)(1.15)Comments 0 - Self Weight (PLF)0 to 2' 10"N/A 7.0 ---- 1 - Uniform (PSF)0 to 2' 10"9'15.0 40.0 -Floor - Upper 2 - Uniform (PSF)0 to 2' 10"1'80.0 --Wall - Upper 3 - Uniform (PSF)0 to 2' 10"1'20.0 -35.0 Snow - Garage 4 - Uniform (PSF)0 to 2' 10"11'20.0 -35.0 Snow - Main Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/document-library. The product application, input design loads, dimensions and support information have been provided by Custom; plan dated 10/26/2020. Weyerhaeuser Notes All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal. MEMBER REPORT PASSED Main Level, Mudroom Bump Out Header 2 piece(s) 2 x 10 Spruce-Pine-Fir No. 1 / No. 2 ForteWEB Software Operator Job Notes 12/16/2020 6:09:37 PM UTCJeffrey Doty, Design Supervisor Lyman Lumber Company (952) 470-4866 jeff_doty@lymanlumber.com ForteWEB v3.1, Engine: V8.1.5.1, Data: V8.0.1.0 File Name: 7726 204th Street W, Lakeville, MN Topaz - The Brooke 7726 204th Street W, Lakeville, MN 12/16/2020; #24535 Page 8 / 26 Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (lbs)1156 @ 1 1/2"3825 (3.00")Passed (30%)--1.0 D + 1.0 S (All Spans) Shear (lbs)878 @ 1' 1/4"2872 Passed (31%)1.15 1.0 D + 1.0 S (All Spans) Moment (Ft-lbs)2314 @ 4' 3"3946 Passed (59%)1.15 1.0 D + 1.0 S (All Spans) Live Load Defl. (in)0.040 @ 4' 3"0.275 Passed (L/999+)--1.0 D + 1.0 S (All Spans) Total Load Defl. (in)0.102 @ 4' 3"0.412 Passed (L/967)--1.0 D + 1.0 S (All Spans) System : Wall Member Type : Header Building Use : Residential Building Code : IBC 2018 Design Methodology : ASD •Deflection criteria: LL (L/360) and TL (L/240). •Allowed moment does not reflect the adjustment for the beam stability factor. •Applicable calculations are based on NDS. Bearing Length Loads to Supports (lbs) Supports Total Available Required Dead Snow Total Accessories 1 - Trimmer - SPF 3.00"3.00"1.50"710 446 1156 None 2 - Trimmer - SPF 3.00"3.00"1.50"710 446 1156 None •Maximum allowable bracing intervals based on applied load. Lateral Bracing Bracing Intervals Comments Top Edge (Lu)8' 6" o/c Bottom Edge (Lu)8' 6" o/c Dead Snow Vertical Loads Location (Side)Tributary Width (0.90)(1.15)Comments 0 - Self Weight (PLF)0 to 8' 6"N/A 7.0 -- 1 - Uniform (PLF)0 to 8' 6"N/A 100.0 -Wall - Gable 2 - Uniform (PSF)0 to 8' 6"3'20.0 35.0 Snow - Main Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/document-library. The product application, input design loads, dimensions and support information have been provided by Custom; plan dated 10/26/2020. Weyerhaeuser Notes All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal. MEMBER REPORT PASSED Main Level, Dining Room Window Rear 2 piece(s) 2 x 10 Spruce-Pine-Fir No. 1 / No. 2 ForteWEB Software Operator Job Notes 12/16/2020 6:09:37 PM UTCJeffrey Doty, Design Supervisor Lyman Lumber Company (952) 470-4866 jeff_doty@lymanlumber.com ForteWEB v3.1, Engine: V8.1.5.1, Data: V8.0.1.0 File Name: 7726 204th Street W, Lakeville, MN Topaz - The Brooke 7726 204th Street W, Lakeville, MN 12/16/2020; #24535 Page 9 / 26 Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (lbs)5390 @ 12' 1"5709 (1.50")Passed (94%)--1.0 D + 1.0 S (All Spans) Shear (lbs)1734 @ 2' 10"11854 Passed (15%)1.15 1.0 D + 0.75 L + 0.75 S (Adj Spans) Moment (Ft-lbs)2148 @ 1' 8 1/2"17977 Passed (12%)1.15 1.0 D + 0.75 L + 0.75 S (Alt Spans) Live Load Defl. (in)0.010 @ 1' 10 7/8"0.132 Passed (L/999+)--1.0 D + 0.75 L + 0.75 S (Alt Spans) Total Load Defl. (in)0.018 @ 1' 10 11/16"0.198 Passed (L/999+)--1.0 D + 0.75 L + 0.75 S (Alt Spans) System : Wall Member Type : Header Building Use : Residential Building Code : IBC 2018 Design Methodology : ASD •Deflection criteria: LL (L/360) and TL (L/240). •Allowed moment does not reflect the adjustment for the beam stability factor. Bearing Length Loads to Supports (lbs) Supports Total Available Required Dead Floor Live Snow Total Accessories 1 - Trimmer - SPF 1.50"1.50"1.50"1083 643/-81 1265 2991/- 81 None 2 - Trimmer - SPF 8.00"8.00"2.36"3931 1747 4995 10673 None 3 - Trimmer - SPF 8.00"8.00"1.50"875 1747 -275 2622/- 275 None 4 - Trimmer - SPF 1.50"1.50"1.50"2217 643/-81 3173 6033/- 81 None •Maximum allowable bracing intervals based on applied load. Lateral Bracing Bracing Intervals Comments Top Edge (Lu)12' 1" o/c Bottom Edge (Lu)12' 1" o/c Dead Floor Live Snow Vertical Loads Location (Side)Tributary Width (0.90)(1.00)(1.15)Comments 0 - Self Weight (PLF)0 to 12' 1"N/A 15.6 ---- 1 - Uniform (PSF)0 to 12' 1"9'15.0 40.0 -Floor - Upper Level 2 - Uniform (PLF)0 to 12' 1"N/A 80.0 --Wall - Upper Level 3 - Uniform (PSF)0 to 4'21'20.0 -35.0 Snow - Main 4 - Point (lb)4'N/A 1829 -3124 Linked from: Owner's Suite Window, Support 1 5 - Point (lb)12' 1"N/A 1829 -3124 Linked from: Owner's Suite Window, Support 2 Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/document-library. The product application, input design loads, dimensions and support information have been provided by Custom; plan dated 10/26/2020. Weyerhaeuser Notes All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal. MEMBER REPORT PASSED Main Level, Great Room Window Rear 3 piece(s) 1 3/4" x 9 1/2" 1.55E TimberStrand® LSL ForteWEB Software Operator Job Notes 12/16/2020 6:09:37 PM UTCJeffrey Doty, Design Supervisor Lyman Lumber Company (952) 470-4866 jeff_doty@lymanlumber.com ForteWEB v3.1, Engine: V8.1.5.1, Data: V8.0.1.0 File Name: 7726 204th Street W, Lakeville, MN Topaz - The Brooke 7726 204th Street W, Lakeville, MN 12/16/2020; #24535 Page 10 / 26 Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (lbs)6462 @ 3' 6"7650 (6.00")Passed (84%)--1.0 D + 1.0 S (All Spans) Shear (lbs)530 @ 4' 6 1/4"2498 Passed (21%)1.00 1.0 D + 1.0 L (All Spans) Moment (Ft-lbs)-693 @ 3' 6"3431 Passed (20%)1.00 1.0 D + 1.0 L (All Spans) Live Load Defl. (in)0.002 @ 1' 8 3/4"0.112 Passed (L/999+)--1.0 D + 0.75 L + 0.75 S (Alt Spans) Total Load Defl. (in)0.003 @ 1' 8 3/16"0.169 Passed (L/999+)--1.0 D + 0.75 L + 0.75 S (Alt Spans) System : Wall Member Type : Header Building Use : Residential Building Code : IBC 2018 Design Methodology : ASD •Deflection criteria: LL (L/360) and TL (L/240). •Allowed moment does not reflect the adjustment for the beam stability factor. •Applicable calculations are based on NDS. Bearing Length Loads to Supports (lbs) Supports Total Available Required Dead Floor Live Snow Total Accessories 1 - Trimmer - SPF 3.00"3.00"1.63"884 384/-51 1191 2459/- 51 None 2 - Trimmer - SPF 6.00"6.00"5.07"2844 1013 3618 7475 None 3 - Trimmer - SPF 3.00"3.00"1.63"884 384/-51 1191 2459/- 51 None •Maximum allowable bracing intervals based on applied load. Lateral Bracing Bracing Intervals Comments Top Edge (Lu)7' o/c Bottom Edge (Lu)7' o/c Dead Floor Live Snow Vertical Loads Location (Side)Tributary Width (0.90)(1.00)(1.15)Comments 0 - Self Weight (PLF)0 to 7'N/A 7.0 ---- 1 - Uniform (PSF)0 to 7'6'15.0 40.0 -Floor - Upper Level 2 - Uniform (PLF)0 to 7'N/A 80.0 --Wall - Upper Level 3 - Uniform (PSF)0 to 7'3' 6"20.0 -35.0 Snow - Porch 4 - Point (lb)0 N/A 540 -1008 Linked from: Bedroom #4 Window, Support 1 5 - Point (lb)3' 6"N/A 1802 -3101 Linked from: Bedroom #4 Window, Support 2 6 - Point (lb)7'N/A 540 -1008 Linked from: Bedroom #4 Window, Support 3 Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/document-library. The product application, input design loads, dimensions and support information have been provided by Custom; plan dated 10/26/2020. Weyerhaeuser Notes All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal. MEMBER REPORT PASSED Main Level, Office Window 2 piece(s) 2 x 10 Spruce-Pine-Fir No. 1 / No. 2 ForteWEB Software Operator Job Notes 12/16/2020 6:09:37 PM UTCJeffrey Doty, Design Supervisor Lyman Lumber Company (952) 470-4866 jeff_doty@lymanlumber.com ForteWEB v3.1, Engine: V8.1.5.1, Data: V8.0.1.0 File Name: 7726 204th Street W, Lakeville, MN Topaz - The Brooke 7726 204th Street W, Lakeville, MN 12/16/2020; #24535 Page 11 / 26 Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (lbs)2802 @ 0 2869 (1.50")Passed (98%)--1.0 D + 0.75 L + 0.75 S (All Spans) Shear (lbs)1146 @ 2' 6 1/4"4308 Passed (27%)1.15 1.0 D + 0.75 L + 0.75 S (All Spans) Moment (Ft-lbs)1597 @ 1' 11 3/16"5919 Passed (27%)1.15 1.0 D + 0.75 L + 0.75 S (All Spans) Live Load Defl. (in)0.005 @ 1' 8 15/16"0.114 Passed (L/999+)--1.0 D + 0.75 L + 0.75 S (All Spans) Total Load Defl. (in)0.009 @ 1' 8 15/16"0.171 Passed (L/999+)--1.0 D + 0.75 L + 0.75 S (All Spans) System : Wall Member Type : Header Building Use : Residential Building Code : IBC 2018 Design Methodology : ASD •Deflection criteria: LL (L/360) and TL (L/240). •Allowed moment does not reflect the adjustment for the beam stability factor. •Applicable calculations are based on NDS. Bearing Length Loads to Supports (lbs) Supports Total Available Required Dead Floor Live Snow Total Accessories 1 - Trimmer - SPF 1.50"1.50"1.50"1229 683 1414 3326 None 2 - Trimmer - SPF 1.50"1.50"1.50"1220 683 1401 3304 None •Maximum allowable bracing intervals based on applied load. Lateral Bracing Bracing Intervals Comments Top Edge (Lu)3' 5" o/c Bottom Edge (Lu)3' 5" o/c Dead Floor Live Snow Vertical Loads Location (Side)Tributary Width (0.90)(1.00)(1.15)Comments 0 - Self Weight (PLF)0 to 3' 5"N/A 10.6 ---- 1 - Uniform (PSF)0 to 3' 5"10'15.0 40.0 -Floor - Upper Level 2 - Uniform (PLF)0 to 3' 5"N/A 80.0 --Wall - Upper Level 3 - Uniform (PSF)0 to 3' 5"1'20.0 -35.0 Snow - Porch 4 - Uniform (PSF)0 to 4"21'20.0 -35.0 Snow - Main 5 - Uniform (PSF)2' 10" to 3' 5"21'20.0 -35.0 Snow - Main 6 - Point (lb)4"N/A 587 -1011 Linked from: Bedroom #4 WIC Window, Support 1 7 - Point (lb)2' 10"N/A 587 -1011 Linked from: Bedroom #4 WIC Window, Support 2 Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/document-library. The product application, input design loads, dimensions and support information have been provided by Custom; plan dated 10/26/2020. Weyerhaeuser Notes All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal. MEMBER REPORT PASSED Main Level, Foyer Entry Door 3 piece(s) 2 x 10 Spruce-Pine-Fir No. 1 / No. 2 ForteWEB Software Operator Job Notes 12/16/2020 6:09:37 PM UTCJeffrey Doty, Design Supervisor Lyman Lumber Company (952) 470-4866 jeff_doty@lymanlumber.com ForteWEB v3.1, Engine: V8.1.5.1, Data: V8.0.1.0 File Name: 7726 204th Street W, Lakeville, MN Topaz - The Brooke 7726 204th Street W, Lakeville, MN 12/16/2020; #24535 Page 12 / 26 Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (lbs)2244 @ 3 1/2"3938 (1.50")Passed (57%)--1.0 D + 1.0 S (All Spans) Shear (lbs)1997 @ 1' 1"7265 Passed (27%)1.15 1.0 D + 1.0 S (All Spans) Moment (Ft-lbs)8064 @ 7' 5 3/4"13541 Passed (60%)1.15 1.0 D + 1.0 S (All Spans) Live Load Defl. (in)0.387 @ 7' 5 3/4"0.479 Passed (L/446)--1.0 D + 1.0 S (All Spans) Total Load Defl. (in)0.628 @ 7' 5 3/4"0.719 Passed (L/275)--1.0 D + 1.0 S (All Spans) System : Roof Member Type : Drop Beam Building Use : Residential Building Code : IBC 2018 Design Methodology : ASD Member Pitch : 0/12 •Deflection criteria: LL (L/360) and TL (L/240). •Allowed moment does not reflect the adjustment for the beam stability factor. • Blocking Panels are assumed to carry no loads applied directly above them and the full load is applied to the member being designed. • At hanger supports, the Total Bearing dimension is equal to the width of the material that is supporting the hanger • ¹ See Connector grid below for additional information and/or requirements. Bearing Length Loads to Supports (lbs) Supports Total Available Required Dead Snow Total Accessories 1 - Hanger on 9 1/2" LSL beam 3.50"Hanger¹1.50"892 1440 2332 See note ¹ 2 - Column - SPF 5.50"5.50"1.50"900 1448 2348 Blocking •Maximum allowable bracing intervals based on applied load. Lateral Bracing Bracing Intervals Comments Top Edge (Lu)14' 4" o/c Bottom Edge (Lu)14' 9" o/c Connector: Simpson Strong-Tie Support Model Seat Length Top Fasteners Face Fasteners Member Fasteners Accessories 1 - Face Mount Hanger U410 2.00"N/A 14-16d 6-10d •Refer to manufacturer notes and instructions for proper installation and use of all connectors. Dead Snow Vertical Loads Location (Side)Tributary Width (0.90)(1.15)Comments 0 - Self Weight (PLF)3 1/2" to 15'N/A 9.7 -- 1 - Uniform (PSF)0 to 15' (Front)5' 6"20.0 35.0 Snow - Porch Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/document-library. The product application, input design loads, dimensions and support information have been provided by Custom; plan dated 10/26/2020. Weyerhaeuser Notes All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal. MEMBER REPORT PASSED Main Level, Drop Beam over Front Porch (H) 2 piece(s) 1 3/4" x 9 1/2" 2.0E Microllam® LVL ForteWEB Software Operator Job Notes 12/16/2020 6:09:37 PM UTCJeffrey Doty, Design Supervisor Lyman Lumber Company (952) 470-4866 jeff_doty@lymanlumber.com ForteWEB v3.1, Engine: V8.1.5.1, Data: V8.0.1.0 File Name: 7726 204th Street W, Lakeville, MN Topaz - The Brooke 7726 204th Street W, Lakeville, MN 12/16/2020; #24535 Page 13 / 26 Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (lbs)3444 @ 11 3/4"13956 (5.50")Passed (25%)--1.0 D + 1.0 S (All Spans) Shear (lbs)2818 @ 2'7902 Passed (36%)1.15 1.0 D + 1.0 S (All Spans) Moment (Ft-lbs)4502 @ 3' 9 1/8"11985 Passed (38%)1.15 1.0 D + 1.0 S (Alt Spans) Live Load Defl. (in)0.108 @ 5' 13/16"0.290 Passed (L/962)--1.0 D + 1.0 S (Alt Spans) Total Load Defl. (in)0.176 @ 5' 7/8"0.434 Passed (L/592)--1.0 D + 1.0 S (Alt Spans) System : Roof Member Type : Drop Beam Building Use : Residential Building Code : IBC 2018 Design Methodology : ASD Member Pitch : 0/12 •Deflection criteria: LL (L/360) and TL (L/240). •Overhang deflection criteria: LL (2L/360) and TL (2L/240). •Allowed moment does not reflect the adjustment for the beam stability factor. • Blocking Panels are assumed to carry no loads applied directly above them and the full load is applied to the member being designed. Bearing Length Loads to Supports (lbs) Supports Total Available Required Dead Snow Total Accessories 1 - Column - SPF 5.50"5.50"1.50"1324 2120 3444 Blocking 2 - Stud wall - SPF 5.50"5.50"1.50"622 988 1610 Blocking •Maximum allowable bracing intervals based on applied load. Lateral Bracing Bracing Intervals Comments Top Edge (Lu)10' o/c Bottom Edge (Lu)10' o/c Dead Snow Vertical Loads Location (Side)Tributary Width (0.90)(1.15)Comments 0 - Self Weight (PLF)0 to 10'N/A 10.4 -- 1 - Uniform (PSF)0 to 2' 6" (Front)5' 6"20.0 35.0 Snow - Porch 2 - Uniform (PSF)2' 6" to 10' (Front)4' 6"20.0 35.0 Snow - Porch 3 - Point (lb)2' 6" (Front)N/A 892 1440 Linked from: Drop Beam over Front Porch (H), Support 1 Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/document-library. The product application, input design loads, dimensions and support information have been provided by Custom; plan dated 10/26/2020. Weyerhaeuser Notes All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal. MEMBER REPORT PASSED Main Level, Drop Beam over Front Porch (V) 2 piece(s) 1 3/4" x 9 1/2" 1.55E TimberStrand® LSL ForteWEB Software Operator Job Notes 12/16/2020 6:09:37 PM UTCJeffrey Doty, Design Supervisor Lyman Lumber Company (952) 470-4866 jeff_doty@lymanlumber.com ForteWEB v3.1, Engine: V8.1.5.1, Data: V8.0.1.0 File Name: 7726 204th Street W, Lakeville, MN Topaz - The Brooke 7726 204th Street W, Lakeville, MN 12/16/2020; #24535 Page 14 / 26 Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (lbs)1241 @ 1 1/2"3825 (3.00")Passed (32%)--1.0 D + 1.0 S (All Spans) Shear (lbs)904 @ 1' 2 1/4"3493 Passed (26%)1.15 1.0 D + 1.0 S (All Spans) Moment (Ft-lbs)2561 @ 4' 4 1/2"5306 Passed (48%)1.15 1.0 D + 1.0 S (All Spans) Live Load Defl. (in)0.041 @ 4' 4 1/2"0.283 Passed (L/999+)--1.0 D + 1.0 S (All Spans) Total Load Defl. (in)0.067 @ 4' 4 1/2"0.425 Passed (L/999+)--1.0 D + 1.0 S (All Spans) System : Wall Member Type : Header Building Use : Residential Building Code : IBC 2018 Design Methodology : ASD •Deflection criteria: LL (L/360) and TL (L/240). •Allowed moment does not reflect the adjustment for the beam stability factor. •Applicable calculations are based on NDS. Bearing Length Loads to Supports (lbs) Supports Total Available Required Dead Snow Total Accessories 1 - Trimmer - SPF 3.00"3.00"1.50"475 766 1241 None 2 - Trimmer - SPF 3.00"3.00"1.50"475 766 1241 None •Maximum allowable bracing intervals based on applied load. Lateral Bracing Bracing Intervals Comments Top Edge (Lu)8' 9" o/c Bottom Edge (Lu)8' 9" o/c Dead Snow Vertical Loads Location (Side)Tributary Width (0.90)(1.15)Comments 0 - Self Weight (PLF)0 to 8' 9"N/A 8.6 -- 1 - Uniform (PSF)0 to 8' 9"5'20.0 35.0 Snow - Garage Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/document-library. The product application, input design loads, dimensions and support information have been provided by Custom; plan dated 10/26/2020. Weyerhaeuser Notes All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal. MEMBER REPORT PASSED Main Level, 8' Garage Door Opening 2 piece(s) 2 x 12 Spruce-Pine-Fir No. 1 / No. 2 ForteWEB Software Operator Job Notes 12/16/2020 6:09:37 PM UTCJeffrey Doty, Design Supervisor Lyman Lumber Company (952) 470-4866 jeff_doty@lymanlumber.com ForteWEB v3.1, Engine: V8.1.5.1, Data: V8.0.1.0 File Name: 7726 204th Street W, Lakeville, MN Topaz - The Brooke 7726 204th Street W, Lakeville, MN 12/16/2020; #24535 Page 15 / 26 Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (lbs)2328 @ 1 1/2"7613 (3.00")Passed (31%)--1.0 D + 1.0 S (All Spans) Shear (lbs)1984 @ 1' 2 7/8"9878 Passed (20%)1.15 1.0 D + 1.0 S (All Spans) Moment (Ft-lbs)9460 @ 8' 4 1/2"18346 Passed (52%)1.15 1.0 D + 1.0 S (All Spans) Live Load Defl. (in)0.244 @ 8' 4 1/2"0.550 Passed (L/811)--1.0 D + 1.0 S (All Spans) Total Load Defl. (in)0.646 @ 8' 4 1/2"0.825 Passed (L/306)--1.0 D + 1.0 S (All Spans) System : Wall Member Type : Header Building Use : Residential Building Code : IBC 2018 Design Methodology : ASD •Deflection criteria: LL (L/360) and TL (L/240). •Allowed moment does not reflect the adjustment for the beam stability factor. Bearing Length Loads to Supports (lbs) Supports Total Available Required Dead Snow Total Accessories 1 - Trimmer - SPF 3.00"3.00"1.50"1449 879 2328 None 2 - Trimmer - SPF 3.00"3.00"1.50"1449 879 2328 None •Maximum allowable bracing intervals based on applied load. Lateral Bracing Bracing Intervals Comments Top Edge (Lu)11' 9" o/c Bottom Edge (Lu)16' 9" o/c Dead Snow Vertical Loads Location (Side)Tributary Width (0.90)(1.15)Comments 0 - Self Weight (PLF)0 to 16' 9"N/A 13.0 -- 1 - Uniform (PSF)0 to 16' 9"3'20.0 35.0 Snow - Garage 2 - Uniform (PLF)0 to 16' 9"N/A 100.0 -Wall - Gable Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/document-library. The product application, input design loads, dimensions and support information have been provided by Custom; plan dated 10/26/2020. Weyerhaeuser Notes All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal. MEMBER REPORT PASSED Main Level, 16' Garage Door Opening 2 piece(s) 1 3/4" x 11 7/8" 1.55E TimberStrand® LSL ForteWEB Software Operator Job Notes 12/16/2020 6:09:37 PM UTCJeffrey Doty, Design Supervisor Lyman Lumber Company (952) 470-4866 jeff_doty@lymanlumber.com ForteWEB v3.1, Engine: V8.1.5.1, Data: V8.0.1.0 File Name: 7726 204th Street W, Lakeville, MN Topaz - The Brooke 7726 204th Street W, Lakeville, MN 12/16/2020; #24535 Page 16 / 26 Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (lbs)8250 @ 3"17128 (4.50")Passed (48%)--1.0 D + 1.0 L (All Spans) Shear (lbs)6611 @ 1' 8 1/2"15960 Passed (41%)1.00 1.0 D + 1.0 L (All Spans) Moment (Ft-lbs)32154 @ 8' 7/8"46671 Passed (69%)1.00 1.0 D + 1.0 L (All Spans) Live Load Defl. (in)0.321 @ 8' 2 1/4"0.400 Passed (L/598)--1.0 D + 1.0 L (All Spans) Total Load Defl. (in)0.453 @ 8' 2 1/4"0.800 Passed (L/424)--1.0 D + 1.0 L (All Spans) System : Floor Member Type : Flush Beam Building Use : Residential Building Code : IBC 2018 Design Methodology : ASD •Deflection criteria: LL (L/480) and TL (L/240). •Allowed moment does not reflect the adjustment for the beam stability factor. Bearing Length Loads to Supports (lbs) Supports Total Available Required Dead Floor Live Total Accessories 1 - Trimmer - SPF 4.50"4.50"2.17"2397 5853 8250 None 2 - Trimmer - SPF 4.50"4.50"1.79"2005 4807 6812 None •Maximum allowable bracing intervals based on applied load. Lateral Bracing Bracing Intervals Comments Top Edge (Lu)10' o/c Bottom Edge (Lu)16' 6" o/c Dead Floor Live Vertical Loads Location (Side)Tributary Width (0.90)(1.00)Comments 0 - Self Weight (PLF)0 to 16' 6"N/A 24.5 -- 1 - Uniform (PSF)0 to 3' 6" (Front)17'15.0 40.0 Floor - Upper Level 2 - Uniform (PSF)3' 6" to 11' 6" (Front)19'15.0 40.0 Floor - Upper Level 3 - Uniform (PSF)11' 6" to 16' 6" (Front)9'15.0 40.0 Floor - Upper Level 4 - Point (lb)11' 6" (Front)N/A 150 400 Floor - Stairs Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/document-library. The product application, input design loads, dimensions and support information have been provided by Custom; plan dated 10/26/2020. Weyerhaeuser Notes All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal. MEMBER REPORT PASSED Main Level, Flush Beam over Stairs/Great Room (H) 3 piece(s) 1 3/4" x 16" 2.0E Microllam® LVL ForteWEB Software Operator Job Notes 12/16/2020 6:09:37 PM UTCJeffrey Doty, Design Supervisor Lyman Lumber Company (952) 470-4866 jeff_doty@lymanlumber.com ForteWEB v3.1, Engine: V8.1.5.1, Data: V8.0.1.0 File Name: 7726 204th Street W, Lakeville, MN Topaz - The Brooke 7726 204th Street W, Lakeville, MN 12/16/2020; #24535 Page 17 / 26 Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (lbs)4653 @ 0 5709 (1.50")Passed (82%)--1.0 D + 0.75 L + 0.75 S (All Spans) Shear (lbs)8975 @ 2' 2"11854 Passed (76%)1.15 1.0 D + 1.0 S (All Spans) Moment (Ft-lbs)8853 @ 2' 3"17977 Passed (49%)1.15 1.0 D + 1.0 S (All Spans) Live Load Defl. (in)0.022 @ 2' 3"0.103 Passed (L/999+)--1.0 D + 1.0 S (All Spans) Total Load Defl. (in)0.043 @ 2' 3"0.154 Passed (L/859)--1.0 D + 1.0 S (All Spans) System : Wall Member Type : Header Building Use : Residential Building Code : IBC 2018 Design Methodology : ASD •Deflection criteria: LL (L/360) and TL (L/240). •Allowed moment does not reflect the adjustment for the beam stability factor. Bearing Length Loads to Supports (lbs) Supports Total Available Required Dead Floor Live Snow Total Accessories 1 - Trimmer - SPF 1.50"1.50"1.50"2219 1238 2008 5465 None 2 - Trimmer - SPF 6.00"6.00"2.91"5468 2042 5420 12930 None •Maximum allowable bracing intervals based on applied load. Lateral Bracing Bracing Intervals Comments Top Edge (Lu)3' 6" o/c Bottom Edge (Lu)3' 6" o/c Dead Floor Live Snow Vertical Loads Location (Side)Tributary Width (0.90)(1.00)(1.15)Comments 0 - Self Weight (PLF)0 to 3' 5 1/2"N/A 15.6 ---- 1 - Uniform (PSF)0 to 2' 3"16' 3"15.0 40.0 -Floor - Upper Level 2 - Uniform (PSF)2' 3" to 3' 5 1/2"21' 3"15.0 40.0 -Floor - Upper Level 3 - Point (lb)2' 3"N/A 6699 791 7428 Linked from: Flush Garage Middle (V), Support 2 Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/document-library. The product application, input design loads, dimensions and support information have been provided by Custom; plan dated 10/26/2020. Weyerhaeuser Notes All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal. MEMBER REPORT PASSED Main Level, Mudroom Entry Door 3 piece(s) 1 3/4" x 9 1/2" 1.55E TimberStrand® LSL ForteWEB Software Operator Job Notes 12/16/2020 6:09:37 PM UTCJeffrey Doty, Design Supervisor Lyman Lumber Company (952) 470-4866 jeff_doty@lymanlumber.com ForteWEB v3.1, Engine: V8.1.5.1, Data: V8.0.1.0 File Name: 7726 204th Street W, Lakeville, MN Topaz - The Brooke 7726 204th Street W, Lakeville, MN 12/16/2020; #24535 Page 18 / 26 Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (lbs)13302 @ 4 1/2"13302 (3.38")Passed (100%)--1.0 D + 1.0 S (All Spans) Shear (lbs)14031 @ 14' 10 3/4"22943 Passed (61%)1.15 1.0 D + 1.0 S (All Spans) Moment (Ft-lbs)72280 @ 8' 9"81355 Passed (89%)1.15 1.0 D + 1.0 S (All Spans) Live Load Defl. (in)0.292 @ 8' 9"0.408 Passed (L/670)--1.0 D + 1.0 S (All Spans) Total Load Defl. (in)0.547 @ 8' 9"0.816 Passed (L/358)--1.0 D + 1.0 S (All Spans) System : Floor Member Type : Flush Beam Building Use : Residential Building Code : IBC 2018 Design Methodology : ASD •Deflection criteria: LL (L/480) and TL (L/240). •Allowed moment does not reflect the adjustment for the beam stability factor. • Blocking Panels are assumed to carry no loads applied directly above them and the full load is applied to the member being designed. • At hanger supports, the Total Bearing dimension is equal to the width of the material that is supporting the hanger • ¹ See Connector grid below for additional information and/or requirements. Bearing Length Loads to Supports (lbs) Supports Total Available Required Dead Floor Live Snow Total Accessories 1 - Hanger on 20" SYP beam 4.50"Hanger¹3.38"6234 770 7475 14479 See note ¹ 2 - Beam - LSL 5.25"5.25"3.79"6699 791 7428 14918 Blocking •Maximum allowable bracing intervals based on applied load. Lateral Bracing Bracing Intervals Comments Top Edge (Lu)4' 3" o/c Bottom Edge (Lu)16' 8" o/c Connector: Simpson Strong-Tie Support Model Seat Length Top Fasteners Face Fasteners Member Fasteners Accessories 1 - Face Mount Hanger Connector not found N/A N/A N/A N/A •Refer to manufacturer notes and instructions for proper installation and use of all connectors. Dead Floor Live Snow Vertical Loads Location (Side)Tributary Width (0.90)(1.00)(1.15)Comments 0 - Self Weight (PLF)4 1/2" to 17'N/A 30.6 ---- 1 - Uniform (PLF)0 to 12' 6" (Front)N/A 80.0 --Wall - Upper Level 2 - Uniform (PSF)0 to 8' 9" (Front)5'20.0 -35.0 Snow - Garage 3 - Uniform (PSF)0 to 12' 6" (Front)13'20.0 -35.0 Snow - Main 4 - Point (lb)12' 6" (Front)N/A 4129 -4594 Roof Girder 5 - Uniform (PSF)0 to 17' (Front)1'15.0 40.0 -Floor - Upper Level 6 - Point (lb)8' 9" (Front)N/A 2915 881 3090 Linked from: GT5, Support 1 All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal. MEMBER REPORT PASSED Main Level, Flush Garage Middle (V) 3 piece(s) 1 3/4" x 20" 2.0E Microllam® LVL ForteWEB Software Operator Job Notes 12/16/2020 6:09:37 PM UTCJeffrey Doty, Design Supervisor Lyman Lumber Company (952) 470-4866 jeff_doty@lymanlumber.com ForteWEB v3.1, Engine: V8.1.5.1, Data: V8.0.1.0 File Name: 7726 204th Street W, Lakeville, MN Topaz - The Brooke 7726 204th Street W, Lakeville, MN 12/16/2020; #24535 Page 19 / 26 Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/document-library. The product application, input design loads, dimensions and support information have been provided by Custom; plan dated 10/26/2020. Weyerhaeuser Notes ForteWEB Software Operator Job Notes 12/16/2020 6:09:37 PM UTCJeffrey Doty, Design Supervisor Lyman Lumber Company (952) 470-4866 jeff_doty@lymanlumber.com ForteWEB v3.1, Engine: V8.1.5.1, Data: V8.0.1.0 File Name: 7726 204th Street W, Lakeville, MN Topaz - The Brooke 7726 204th Street W, Lakeville, MN 12/16/2020; #24535 Page 20 / 26 Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (lbs)1732 @ 5 1/2"1913 (1.50")Passed (91%)--1.0 D + 1.0 S (All Spans) Shear (lbs)1407 @ 1' 2 3/4"2872 Passed (49%)1.15 1.0 D + 1.0 S (All Spans) Moment (Ft-lbs)3554 @ 4' 6 3/4"3946 Passed (90%)1.15 1.0 D + 1.0 S (All Spans) Live Load Defl. (in)0.052 @ 4' 6 3/4"0.205 Passed (L/999+)--1.0 D + 1.0 S (All Spans) Total Load Defl. (in)0.156 @ 4' 6 3/4"0.410 Passed (L/633)--1.0 D + 1.0 S (All Spans) System : Floor Member Type : Flush Beam Building Use : Residential Building Code : IBC 2018 Design Methodology : ASD •Deflection criteria: LL (L/480) and TL (L/240). •Allowed moment does not reflect the adjustment for the beam stability factor. •Applicable calculations are based on NDS. • At hanger supports, the Total Bearing dimension is equal to the width of the material that is supporting the hanger • ¹ See Connector grid below for additional information and/or requirements. Bearing Length Loads to Supports (lbs) Supports Total Available Required Dead Floor Live Snow Total Accessories 1 - Hanger on 9 1/4" SPF beam 5.50"Hanger¹1.50"1284 183 639 2106 See note ¹ 2 - Trimmer - SPF 5.50"5.50"1.50"1252 178 621 2051 None •Maximum allowable bracing intervals based on applied load. Lateral Bracing Bracing Intervals Comments Top Edge (Lu)6' 11" o/c Bottom Edge (Lu)8' 7" o/c Connector: Simpson Strong-Tie Support Model Seat Length Top Fasteners Face Fasteners Member Fasteners Accessories 1 - Face Mount Hanger LUS210-2 2.00"N/A 8-16d 6-16d •Refer to manufacturer notes and instructions for proper installation and use of all connectors. Dead Floor Live Snow Vertical Loads Location (Side)Tributary Width (0.90)(1.00)(1.15)Comments 0 - Self Weight (PLF)5 1/2" to 9'N/A 7.0 ---- 1 - Uniform (PSF)0 to 9' (Front)1'15.0 40.0 -Floor - Upper 2 - Uniform (PLF)0 to 9' (Front)N/A 80.0 --Wall - Upper 3 - Uniform (PSF)0 to 9' (Front)1'20.0 -35.0 Snow - Garage 4 - Uniform (PLF)0 to 9' (Front)N/A 100.0 --Wall - Gable 5 - Uniform (PSF)0 to 9' (Front)3'20.0 -35.0 Snow - Main Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/document-library. The product application, input design loads, dimensions and support information have been provided by Custom; plan dated 10/26/2020. Weyerhaeuser Notes All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal. MEMBER REPORT PASSED Main Level, Flush Garage End (V) 2 piece(s) 2 x 10 Spruce-Pine-Fir No. 1 / No. 2 ForteWEB Software Operator Job Notes 12/16/2020 6:09:37 PM UTCJeffrey Doty, Design Supervisor Lyman Lumber Company (952) 470-4866 jeff_doty@lymanlumber.com ForteWEB v3.1, Engine: V8.1.5.1, Data: V8.0.1.0 File Name: 7726 204th Street W, Lakeville, MN Topaz - The Brooke 7726 204th Street W, Lakeville, MN 12/16/2020; #24535 Page 21 / 26 Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (lbs)8589 @ 3"17128 (4.50")Passed (50%)--1.0 D + 0.75 L + 0.75 S (All Spans) Shear (lbs)5951 @ 1' 2"10308 Passed (58%)1.00 1.0 D + 1.0 L (All Spans) Moment (Ft-lbs)14747 @ 4' 6"15633 Passed (94%)1.00 1.0 D + 1.0 L (All Spans) Live Load Defl. (in)0.214 @ 4' 5 1/16"0.275 Passed (L/463)--1.0 D + 0.75 L + 0.75 S (All Spans) Total Load Defl. (in)0.368 @ 4' 5 1/16"0.412 Passed (L/269)--1.0 D + 0.75 L + 0.75 S (All Spans) System : Wall Member Type : Header Building Use : Residential Building Code : IBC 2018 Design Methodology : ASD •Deflection criteria: LL (L/360) and TL (L/240). •Allowed moment does not reflect the adjustment for the beam stability factor. Bearing Length Loads to Supports (lbs) Supports Total Available Required Dead Floor Live Snow Total Accessories 1 - Trimmer - SPF 4.50"4.50"2.26"3613 4375 2260 10248 None 2 - Trimmer - SPF 4.50"4.50"2.25"3599 4375 2246 10220 None •Maximum allowable bracing intervals based on applied load. Lateral Bracing Bracing Intervals Comments Top Edge (Lu)8' 9" o/c Bottom Edge (Lu)8' 9" o/c Dead Floor Live Snow Vertical Loads Location (Side)Tributary Width (0.90)(1.00)(1.15)Comments 0 - Self Weight (PLF)0 to 8' 9"N/A 15.6 ---- 1 - Uniform (PSF)0 to 8' 9"9'15.0 40.0 -Floor - Main Level 2 - Uniform (PLF)0 to 8' 9"N/A 90.0 --Wall - Main Level 3 - Uniform (PSF)0 to 8' 9"7'10.0 40.0 -Floor - Deck 4 - Uniform (PSF)0 to 8' 9"9'15.0 40.0 -Floor - Upper Level 5 - Uniform (PLF)0 to 8' 9"N/A 80.0 --Wall - Upper Level 6 - Uniform (PSF)0 to 1' 3"11'20.0 -35.0 Snow - Main 7 - Uniform (PSF)6' 3" to 8' 9"13'20.0 -35.0 Snow - Main 8 - Point (lb)1' 3"N/A 844 -1444 Linked from: Bedroom #5 Window, Support 1 9 - Point (lb)6' 3"N/A 844 -1444 Linked from: Bedroom #5 Window, Support 2 Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/document-library. The product application, input design loads, dimensions and support information have been provided by Custom; plan dated 10/26/2020. Weyerhaeuser Notes All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal. MEMBER REPORT PASSED Lower Level, Family Room Window 3 piece(s) 1 3/4" x 9 1/2" 1.55E TimberStrand® LSL ForteWEB Software Operator Job Notes 12/16/2020 6:09:37 PM UTCJeffrey Doty, Design Supervisor Lyman Lumber Company (952) 470-4866 jeff_doty@lymanlumber.com ForteWEB v3.1, Engine: V8.1.5.1, Data: V8.0.1.0 File Name: 7726 204th Street W, Lakeville, MN Topaz - The Brooke 7726 204th Street W, Lakeville, MN 12/16/2020; #24535 Page 22 / 26 Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (lbs)2619 @ 1 1/2"5738 (3.00")Passed (46%)--1.0 D + 0.75 L + 0.75 S (All Spans) Shear (lbs)1390 @ 1' 1/4"3746 Passed (37%)1.00 1.0 D + 1.0 L (All Spans) Moment (Ft-lbs)3663 @ 4' 3"5147 Passed (71%)1.00 1.0 D + 1.0 L (All Spans) Live Load Defl. (in)0.060 @ 4' 3"0.275 Passed (L/999+)--1.0 D + 1.0 L (All Spans) Total Load Defl. (in)0.108 @ 4' 3"0.412 Passed (L/917)--1.0 D + 1.0 L (All Spans) System : Wall Member Type : Header Building Use : Residential Building Code : IBC 2018 Design Methodology : ASD •Deflection criteria: LL (L/360) and TL (L/240). •Allowed moment does not reflect the adjustment for the beam stability factor. •Applicable calculations are based on NDS. Bearing Length Loads to Supports (lbs) Supports Total Available Required Dead Floor Live Snow Total Accessories 1 - Trimmer - SPF 3.00"3.00"1.50"1520 1020 446 2986 None 2 - Trimmer - SPF 3.00"3.00"1.50"1520 1020 446 2986 None •Maximum allowable bracing intervals based on applied load. Lateral Bracing Bracing Intervals Comments Top Edge (Lu)8' 6" o/c Bottom Edge (Lu)8' 6" o/c Dead Floor Live Snow Vertical Loads Location (Side)Tributary Width (0.90)(1.00)(1.15)Comments 0 - Self Weight (PLF)0 to 8' 6"N/A 10.6 ---- 1 - Uniform (PSF)0 to 8' 6"6'15.0 40.0 -Floor - Main Level 2 - Uniform (PLF)0 to 8' 6"N/A 90.0 --Wall - Main Level 3 - Point (lb)0 N/A 710 -446 Linked from: Dining Room Window Rear, Support 1 4 - Point (lb)8' 6"N/A 710 -446 Linked from: Dining Room Window Rear, Support 2 Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/document-library. The product application, input design loads, dimensions and support information have been provided by Custom; plan dated 10/26/2020. Weyerhaeuser Notes All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal. MEMBER REPORT PASSED Lower Level, Games Room Window Rear 3 piece(s) 2 x 10 Spruce-Pine-Fir No. 1 / No. 2 ForteWEB Software Operator Job Notes 12/16/2020 6:09:37 PM UTCJeffrey Doty, Design Supervisor Lyman Lumber Company (952) 470-4866 jeff_doty@lymanlumber.com ForteWEB v3.1, Engine: V8.1.5.1, Data: V8.0.1.0 File Name: 7726 204th Street W, Lakeville, MN Topaz - The Brooke 7726 204th Street W, Lakeville, MN 12/16/2020; #24535 Page 23 / 26 Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (lbs)2948 @ 1 1/2"7613 (3.00")Passed (39%)--1.0 D + 1.0 L (All Spans) Shear (lbs)2328 @ 1' 1/2"6872 Passed (34%)1.00 1.0 D + 1.0 L (All Spans) Moment (Ft-lbs)5493 @ 2' 9"10422 Passed (53%)1.00 1.0 D + 1.0 L (All Spans) Live Load Defl. (in)0.055 @ 2' 9"0.175 Passed (L/999+)--1.0 D + 1.0 L (All Spans) Total Load Defl. (in)0.086 @ 2' 9"0.262 Passed (L/732)--1.0 D + 1.0 L (All Spans) System : Wall Member Type : Header Building Use : Residential Building Code : IBC 2018 Design Methodology : ASD •Deflection criteria: LL (L/360) and TL (L/240). •Allowed moment does not reflect the adjustment for the beam stability factor. Bearing Length Loads to Supports (lbs) Supports Total Available Required Dead Floor Live Snow Total Accessories 1 - Trimmer - SPF 3.00"3.00"1.50"1085 1864 -138 2949/- 138 None 2 - Trimmer - SPF 3.00"3.00"1.50"1085 1864 -138 2949/- 138 None •Maximum allowable bracing intervals based on applied load. Lateral Bracing Bracing Intervals Comments Top Edge (Lu)5' 6" o/c Bottom Edge (Lu)5' 6" o/c Dead Floor Live Snow Vertical Loads Location (Side)Tributary Width (0.90)(1.00)(1.15)Comments 0 - Self Weight (PLF)0 to 5' 6"N/A 10.4 ---- 1 - Uniform (PSF)0 to 5' 6"9'15.0 40.0 -Floor - Main Level 2 - Uniform (PLF)0 to 5' 6"N/A 90.0 --Wall - Main Level 3 - Point (lb)2' 9"N/A 875 1747 -275 Linked from: Great Room Window Rear, Support 3 Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/document-library. The product application, input design loads, dimensions and support information have been provided by Custom; plan dated 10/26/2020. Weyerhaeuser Notes All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal. MEMBER REPORT PASSED Lower Level, Bedroom #4 Window 2 piece(s) 1 3/4" x 9 1/2" 1.55E TimberStrand® LSL ForteWEB Software Operator Job Notes 12/16/2020 6:09:37 PM UTCJeffrey Doty, Design Supervisor Lyman Lumber Company (952) 470-4866 jeff_doty@lymanlumber.com ForteWEB v3.1, Engine: V8.1.5.1, Data: V8.0.1.0 File Name: 7726 204th Street W, Lakeville, MN Topaz - The Brooke 7726 204th Street W, Lakeville, MN 12/16/2020; #24535 Page 24 / 26 Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (lbs)3174 @ 1 1/2"3825 (3.00")Passed (83%)--1.0 D + 1.0 L (All Spans) Shear (lbs)1833 @ 1' 1/4"2498 Passed (73%)1.00 1.0 D + 1.0 L (All Spans) Moment (Ft-lbs)3449 @ 2' 5"3431 Passed (100%)1.00 1.0 D + 1.0 L (All Spans) Live Load Defl. (in)0.034 @ 2' 5"0.153 Passed (L/999+)--1.0 D + 1.0 L (All Spans) Total Load Defl. (in)0.047 @ 2' 5"0.229 Passed (L/999+)--1.0 D + 1.0 L (All Spans) System : Wall Member Type : Header Building Use : Residential Building Code : IBC 2018 Design Methodology : ASD •Deflection criteria: LL (L/360) and TL (L/240). •Allowed moment does not reflect the adjustment for the beam stability factor. •Applicable calculations are based on NDS. Bearing Length Loads to Supports (lbs) Supports Total Available Required Dead Floor Live Total Accessories 1 - Trimmer - SPF 3.00"3.00"2.49"878 2296 3174 None 2 - Trimmer - SPF 3.00"3.00"2.49"878 2296 3174 None •Maximum allowable bracing intervals based on applied load. Lateral Bracing Bracing Intervals Comments Top Edge (Lu)6" o/c Bottom Edge (Lu)4' 10" o/c Dead Floor Live Vertical Loads Location (Side)Tributary Width (0.90)(1.00)Comments 0 - Self Weight (PLF)0 to 4' 10"N/A 7.0 -- 1 - Uniform (PSF)0 to 4' 10"23' 9"15.0 40.0 Floor - Main Level Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/document-library. The product application, input design loads, dimensions and support information have been provided by Custom; plan dated 10/26/2020. Weyerhaeuser Notes All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal. MEMBER REPORT PASSED Lower Level, Hallway Opening 2 piece(s) 2 x 10 Spruce-Pine-Fir No. 1 / No. 2 ForteWEB Software Operator Job Notes 12/16/2020 6:09:37 PM UTCJeffrey Doty, Design Supervisor Lyman Lumber Company (952) 470-4866 jeff_doty@lymanlumber.com ForteWEB v3.1, Engine: V8.1.5.1, Data: V8.0.1.0 File Name: 7726 204th Street W, Lakeville, MN Topaz - The Brooke 7726 204th Street W, Lakeville, MN 12/16/2020; #24535 Page 25 / 26 Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (lbs)6772 @ 1 1/2"11419 (3.00")Passed (59%)--1.0 D + 1.0 L (All Spans) Shear (lbs)5572 @ 1' 5"13965 Passed (40%)1.00 1.0 D + 1.0 L (All Spans) Moment (Ft-lbs)26246 @ 8'36387 Passed (72%)1.00 1.0 D + 1.0 L (All Spans) Live Load Defl. (in)0.375 @ 8'0.394 Passed (L/504)--1.0 D + 1.0 L (All Spans) Total Load Defl. (in)0.529 @ 8'0.788 Passed (L/357)--1.0 D + 1.0 L (All Spans) System : Floor Member Type : Flush Beam Building Use : Residential Building Code : IBC 2018 Design Methodology : ASD •Deflection criteria: LL (L/480) and TL (L/240). •Allowed moment does not reflect the adjustment for the beam stability factor. Bearing Length Loads to Supports (lbs) Supports Total Available Required Dead Floor Live Total Accessories 1 - Trimmer - SPF 3.00"3.00"1.78"1972 4800 6772 None 2 - Trimmer - SPF 3.00"3.00"1.78"1972 4800 6772 None •Maximum allowable bracing intervals based on applied load. Lateral Bracing Bracing Intervals Comments Top Edge (Lu)11' 3" o/c Bottom Edge (Lu)16' o/c Dead Floor Live Vertical Loads Location (Side)Tributary Width (0.90)(1.00)Comments 0 - Self Weight (PLF)0 to 16'N/A 21.5 -- 1 - Uniform (PSF)0 to 16' (Front)15'15.0 40.0 Floor - Main Level Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/document-library. The product application, input design loads, dimensions and support information have been provided by Custom; plan dated 10/26/2020. Weyerhaeuser Notes All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal. MEMBER REPORT PASSED Lower Level, Flush Game (H) 3 piece(s) 1 3/4" x 14" 2.0E Microllam® LVL ForteWEB Software Operator Job Notes 12/16/2020 6:09:37 PM UTCJeffrey Doty, Design Supervisor Lyman Lumber Company (952) 470-4866 jeff_doty@lymanlumber.com ForteWEB v3.1, Engine: V8.1.5.1, Data: V8.0.1.0 File Name: 7726 204th Street W, Lakeville, MN Topaz - The Brooke 7726 204th Street W, Lakeville, MN 12/16/2020; #24535 Page 26 / 26 Date Certificate Posted X Passive (No Fan) Active (With fan and monometer or other system monitoring device) Location (or future location) of Fan: Other Please Describe Here R-15 X R-20 X R-20 X R-20 X R-49 X R-49 X R-30 X R-30 X X Not applicable, all ducts located in conditioned space X Not required per mech. code Passive Powered Interlocked with exhaust device. Describe: Input in BTUS: 90,000 Capacity in Gallons: Other, describe: AFUE or HSPF% 95 Cfm's " round duct OR " metal duct Not required per mech. code X Passive X Low: Other, describe: Low: Location of fan(s), describe: Cfm's X " round duct OR 6" flex " metal duct City Mailing Address of the Dwelling or Dwelling Unit Combustion Air Select a Type Location of duct or system: 3 Below Entire Slab Rigid, Extruded Polystyrene Ceiling, flat Per R401.3 Certificate. A building certificate shall be posted on or in the electrical distribution panel.1/20/2021 New Construction Energy Code Compliance Certificate Name of Residential Contractor One Ten Ten Homes, LLC MN License Number Lakeville7726 204th St. BC730925 Mechanical room 110Heat Recover Ventilator (HRV) Capacity in cfms: Energy Recover Ventilator (ERV) Capacity in cfms: 78453 Heating Gain Cooling Load Fuel Type Solar Heat Gain Coefficient (SHGC): Windows & Doors Ceiling, vaulted Bay Windows or cantilevered areas Floors over unconditioned area Rim Joist (2nd Floor+) 0.28 Appliances THERMAL ENVELOPE Foam Open Cell Wall Rigid, Isocynurate Perimeter of Slab on Grade RADON CONTROL SYSTEM Non or Not Applicable Cooling SystemTotal R-Value of all Types of InsulationType: Check All That Apply Mineral Fiberboard Insulation Location Foam, Closed Cell0.21 Describe other insulated areas Fiberglass, BlownFiberglass, Batts Foundation Wall R-value Average U-Factor (excludes skylights and one door ) U: Duct system air tightness: Building envelope air tightness: Rim Joist (1st Floor) GPVL5000L 13ACX036P Model Heating System Natural Gas Lennox Location of duct or system: Heating or Cooling Ducts Outside Conditioned Spaces Electric Make-up Air Select a Type AO Smith Domestic Water Heater MECHANICAL SYSTEMS Rating or Size Efficiency 13 Select Type Describe any additional or combined heating or cooling systems if installed: (e.g. two furnaces or air source heat pump with gas back-up furnace): 35582Residential Load Calculation SEER /EER 200 Total ventilation (intermittent + continuous) rate in cfms: Balanced Ventilation capacity in cfms: High: High: MECHANICAL VENTILATION SYSTEM Capacity continuous ventilation rate in cfms: ML193UH09048C Heating Loss Manufacturer Lennox Natural Gas Output in Tons: 350 Builders Associaton of Minnesota version 101014 NEW RESIDENTIAL CONSTRUCTION SWPPP VERIFICATION This form must be completed and submitted with all new residential permit applications. New residential building permits WILL NOT be issued without this completed form. Project Site Address: _____________________________________________________________________ Company Name: _________________________________________________________________________ Primary Contact: _________________________________________________________________________ Phone # (24 hr Contact): ______________________ Email: ______________________________________ Description of Land Disturbing Activity: _____________________________________________________ NPDES Construction Stormwater Permit # C000 ___ ___ ___ ___ ___ or # SUB00 ___ ___ ___ ___ ___ If you are not covered under a NPDES Construction Stormwater Permit administered by the MPCA, an erosion and sediment control plan MUST be submitted with the residential building permit application. Contact information of person CERTIFIED to provide weekly onsite erosion and sediment control inspections and corrective actions: Name of Person: ________________________________Company: _______________________________ Phone # (24 hr Contact): ______________________ Email: ______________________________________ Entity that Provided Training: ________________________ Certification Expiration Date: ____________ NOTE: Prior to any land-disturbing activity, all erosion and sediment controls must be installed on the project site and on individual lots. No land disturbing activity may begin until a residential building permit has been issued. I understand, the above information to be true and I will have read, understood, and accepted all terms and conditions of the National Pollutant Discharge Elimination System (NPDES) Permit (MN R 100001). The City of Lakeville may issue a STOP WORK ORDER; withhold building inspections; or, draw on securities/escrows to bring the site into compliance with the NPDES Construction Stormwater Permit (MN R 100001) or erosion and sediment control plan. Signature: ________________________________________________ Date:_________________________ Contact the City of Lakeville with questions at erosion@lakevillemn.gov or 952-985-4500 * If awaiting a MPCA permit transfer, provide MPCA proof of transfer submittal e-mail along with this form to erosion@lakevillemn.gov “The permittee(s) shall ensure that the individuals are trained by local, state, federal agencies, professional organizations or other entities in erosion prevention, sediment control, permanent Stormwater management and the Minnesota NPDES/SDS Construction Stormwater Permit.” (NPDES Construction Stormwater Permit, MPCA) “The permittee(s) must ensure that a trained person (as identified in Part III.A.3.a) will routinely inspect the entire construction site at least once every seven (7) days during active construction and within 24 hours after a rainfall event greater than 0.5 inches in 24 hours.” (NPDES Construction Stormwater Permit, MPCA) X KP 01/29/21