HomeMy WebLinkAboutLA187573 - 20998 Junco Trail 1.14.21PAGE SIZEJOB NUMBER B SITE NUMBER DRAWING NUMBER SCALE DATEDESCRIPTIONREVREVISION HISTORYREVDRWDRWCHKDRW PROJECT ADDRESS 20998 JUNCO TRAIL,LAKEVILLE, MN 55044 0 DRAFT REVIEW DRAWING TITLE PROJECT OWNER CONTRACTOR: 12/21/20SK TEL. NO. 1-800-467-4562 AHJ APN. MIKE JORDAN - 15485 UTILITY COMPANY 226481104080 EMPIRE SOLARGROUP WWW.EMPIRESOLARGROUP.COM 1 COMMENTS INCORPORATED 01/04/20DG LAKEVILLE 2 COMMENTS INCORPORATED 01/06/21AP PV-01 COVER SHEET VICINITY VIEW PROJECT LOCATION DESIGN CRITERIA WIND SPEED: 115 MPH EXPOSURE CATEGORY: B SNOW LOAD: 5 PSF OCCUPANCY: II N.T.S. INDEX/INDICATORS PV-01 COVER SHEET PV-02 SITE PLAN PV-03 ROOF PLAN PV-04 SINGLE LINE DIAGRAM PV-05 MOUNTING DETAIL PV-06 LABELS AND PLACARD PV-07 INTERCONNECTIONPHOTOS PV-08 DATASHEET FL-01 BOM FL-02 STRING PLAN FL-03 ASBUILT FL-04 OPTIMIZER MAP FL-05 JOB CHECK SHEET ABBREVIATIONS (E)EXISTING (N)NEWGNDGROUNDPNLPANEL BOARD OR PANEL J-BOX JUNCTION BOXMONMONITORING MSP MAIN SERVICE PANELMONMONITORING PVC POLYVINYL CHLORIDEEMT ELECTRIC METAL TUBING FMC FLEXIBLE METAL CONDUIT USE UNDERGROUND SERVICE ENTRANCENEMANATIONAL ELECTRIC MANUFACTURES ASSOCIATIONWWATTS KW 1,000 WATTSMMETER GENERAL NOTES: 1.1.1 PROJECT NOTES:1.1.2 THIS PHOTOVOLTAIC (PV) SYSTEM SHALL COMPLY WITH THE LISTING AND INSTALLATION INSTRUCTIONS, AND THE RELEVANT CODES APPLICABLE CODES.1.1.3 THE UTILITY INTERCONNECTION APPLICATION MUST BE APPROVED AND PV SYSTEM INSPECTED PRIOR TO PARALLEL OPERATION.1.1.4 GROUND FAULT DETECTION AND INTERRUPTION (GFDI) DEVICE IS INTEGRATED WITH THE MICROINVERTER IN ACCORDANCE WITH NEC690.5(A).1.1.5 ALL PV SYSTEM COMPONENTS; MODULES, UTILITY-INTERACTIVE INVERTERS, AND SOURCE CIRCUIT COMBINER BOXES ARE IDENTIFIEDAND LISTED FOR USE IN PHOTOVOLTAIC SYSTEMS AS REQUIRED BY NEC 690.4 & NEC 690.60:PV MODULES: UL1703, IEC61730, AND IEC61215, AND NFPA 70 CLASS C FIRE.INVERTERS: UL 1741 CERTIFIED, IEEE 1547, 929, 519. COMBINER BOX(ES): UL 1703 OR UL 1741 ACCESSORY. 1.1.6 MAX DC VOLTAGE CALCULATED USING MANUFACTURER PROVIDEDTEMP COEFFICIENT FOR VOC. IF UNAVAILABLE, MAX DC VOLTAGE CALCULATED ACCORDING TO NEC 690.7.1.1.7 ALL INVERTERS, PHOTOVOLTAIC MODULES, PHOTOVOLTAIC PANELS, AND SOURCE CIRCUIT COMBINERS INTENDED FOR USE IN APHOTOVOLTAIC POWER SYSTEM WILL BE IDENTIFIED AND LISTED FOR THE APPLICATION PER 690.4 (D). SHALL BE INSTALLED ACCORDING TOANY INSTRUCTIONS FROM LISTING OR LABELING [NEC 110.3]. 1.1.8 ALL SIGNAGE TO BE PLACED IN ACCORDANCE WITH LOCAL BUILDING CODE. IF EXPOSED TO SUNLIGHT, IT SHALL BE UV RESISTANT. ALLPLAQUES AND SIGNAGE WILL BE INSTALLED AS REQUIRED BY THE NEC AND AHJ. 1.2.1 SCOPE OF WORK:1.2.2 PRIME CONTRACTOR IS RESPONSIBLE FOR THE DESIGN AND SPECIFICATIONS OF THE GRID-TIED PHOTOVOLTAIC SYSTEM RETROFIT.PRIME CONTRACTOR WILL BE RESPONSIBLE FOR COLLECTING EXISTINGONSITE REQUIREMENTS TO DESIGN, SPECIFY, AND INSTALL THEEXTERIOR ROOF-MOUNTED PORTION OF THE PHOTOVOLTAIC SYSTEMSDETAILED IN THIS DOCUMENT. AERIAL VIEW SYSTEM INFORMATION SYSTEM SIZE (kW):8.03 NO. OF MODULES:22 SITE INFORMATION PROJECT NAME:MIKE JORDAN PROJECT ADDRESS:20998 JUNCO TRAIL,LAKEVILLE, MN 55044 INVERTERS:1 (N)SOLAREDGE SE7600H-US (240V) (N)SOLARIA POWERXT-365R-PD CODES 2017 NATIONAL ELECTRIC CODE (NEC).2018 INTERNATIONAL BUILDING CODE (IBC) 2003 EDITION.2018 INTERNATIONAL RESIDENTIAL CODE (IRC) 2000 EDITION.2018 INTERNATIONAL MECHANICAL CODE (IMC). 2018 INTERNATIONAL PLUMBING CODE (IPC).2018 INTERNATIONAL EXISTING BUILDING CODE (IEBC). PARCEL MAP DRIVEWAYYYYY 121'-1" 133'-6" 183'-6" 33'-4" 123'-3"123'-3" 53'-8" 31'-1"56'-2"48'-7"77'-4" 73'-2"----JANCO TRAIL----70'-8" ----210TH ST W---- 10'10'10'10'10'10'5'5' ARRAY AZIMUTH224 & 134DEGREES W NN MAIN SERVICE PANEL (E / INSIDE) CONDUIT RUN (ON ROOF) JUNCTION BOX (ON ROOF) UTILITY METER (E) PV MODULE(N) PHOTOVOLTAIC SYSTEM UTILITY DISCONNECT SWITCH (N) FIRE SETBACKS (3' MIN.) INVERTER (N/ OUTSIDE) RESIDENCE OPTIMIZER(N) ROOF ACCESS POINT PV PRODUCTION METER 1 2 3 4 5 6 7 PAGE SIZEJOB NUMBER B SITE NUMBER DRAWING NUMBER SCALE DATEDESCRIPTIONREVREVISION HISTORYREVDRWDRWCHKDRW PROJECT ADDRESS 20998 JUNCO TRAIL,LAKEVILLE, MN 55044 0 DRAFT REVIEW DRAWING TITLE PROJECT OWNER CONTRACTOR: 12/21/20SK TEL. NO. 1-800-467-4562 AHJ APN. MIKE JORDAN - 15485 UTILITY COMPANY 226481104080 EMPIRE SOLARGROUP WWW.EMPIRESOLARGROUP.COM 1 COMMENTS INCORPORATED 01/04/20DG LAKEVILLE 2 COMMENTS INCORPORATED 01/06/21AP PV-02 SITE PLAN 1"=30' 0 Scale:(For 11x17 Print)1" = 30 15 30'60' MODULE ALLOCATION ROOF PLANE A B C D E AZIMUTH 224 134 TILT 30 30 # OF MODULES 16 6 8 9 PROPERTY LINE 5' FIELD VERIFY ALL MEASUREMENTS.3FT MINIMUM FIREMAN ACCESS. 24/7 UNESCORTED KEYLESS ACCESS IS TO BE PROVIDED FOR ALL UTILITY EQUIPMENT NOTE: SYSTEM AC OUTPUT:7.6 kW SYSTEM DC INPUT:8.03 kW 10 7 510 9 3 1 11 12 ARRAY AZIMUTH 224 & 134 DEGREES W PAGE SIZEJOB NUMBER B SITE NUMBER DRAWING NUMBER SCALE DATEDESCRIPTIONREVREVISION HISTORYREVDRWDRWCHKDRW PROJECT ADDRESS 20998 JUNCO TRAIL,LAKEVILLE, MN 55044 0 DRAFT REVIEW DRAWING TITLE PROJECT OWNER CONTRACTOR: 12/21/20SK TEL. NO. 1-800-467-4562 AHJ APN. MIKE JORDAN - 15485 UTILITY COMPANY 226481104080 EMPIRE SOLARGROUP WWW.EMPIRESOLARGROUP.COM 1 COMMENTS INCORPORATED 01/04/20DG LAKEVILLE 2 COMMENTS INCORPORATED 01/06/21AP PV-03 ROOF PLAN 1"= 10' 0 Scale: (For 11x17 Print) 1" = 10' 5'10'15' LOCATION OF ATTACHMENT POINTS FIRE SETBACKS (3' MIN)2X4 TRUSSES @24" O.C. ARRAY-1 ARRAY-2 PAGE SIZEJOB NUMBER B SITE NUMBER DRAWING NUMBER SCALE DATEDESCRIPTIONREVREVISION HISTORYREVDRWDRWCHKDRW PROJECT ADDRESS 20998 JUNCO TRAIL,LAKEVILLE, MN 55044 0 DRAFT REVIEW DRAWING TITLE PROJECT OWNER CONTRACTOR: 12/21/20SK TEL. NO. 1-800-467-4562 AHJ APN. MIKE JORDAN - 15485 UTILITY COMPANY 226481104080 EMPIRE SOLARGROUP WWW.EMPIRESOLARGROUP.COM 1 COMMENTS INCORPORATED 01/04/20DG LAKEVILLE 2 COMMENTS INCORPORATED 01/06/21AP PV-04 SINGLE LINE DIAGRAM N.T.S. CALCULATIONS MAXIMUM DC CURRENT (A)OPTIMIZER X 1.25 18.75 OPERATING DC CURRENT (A)MODULE IMP 9.16 AC OUTPUT (A)(INVERTER) INVERTER IAC X 1.25 40.0 TOTAL AC OUTPUT (A)40.0 MAXIMUM DC VOLTAGE (V)TEMP. COEFF. 561.2 DC OPERATING VOLTAGE (V)(MOD./STRING)X MOD. VMP 438.9 MAIN SERVICE PANEL INFO VOLTAGE 240 V PHASES 1 BOX/BUS RATING 200 A MAIN BREAKER RATING 150 A SYSTEM INFORMATION # OF MODULES 22 # OF STRINGS 2 # OF MODULES PER STRING 11 11 TOTAL POWER (kW)8.03 INTERCONNECTION 120% RULE (NEC705.12(D)(2)) SOLAR BREAKER +MAIN BREAKER 190 MSP RATING X 120%240 PV MODULE SPECIFICATIONS MAKE (N)SOLARIAPOWERXT-365R-PD NOMINAL OUTPUT POWER (W)365 EQUIPMENT KEY TYPE DESCRIPTION 1 PV MODULE (N)SOLARIA POWERXT-365R-PD 2 INVERTER (N)SOLAREDGE SE7600H-US (240V) 3 DC DISCONNECT INVERTER INTEGRATED 4 UTILITY DISCONNECT PV SYSTEM UTILITY DISCONNECT SW(VISIBLE OPEN, NO FUSES) SQUARE D 60A, 2P,240VAC NEMA 3R 5 MAIN SERVICE PANEL (E)MAIN SERVICE PANEL 200A RATED WITH 150AMAIN BREAKER 6 OPTIMIZERS SOLAREDGE POWER OPTIMIZERS P400 7 PV PRODUCTIONMETER(N)PV METER 1-PHASE, 3-WIRED DESCRIPTION CONDUCTORSIZE APPROXIMATE AREAOF CONDUCTOR (NECCHAPTER-9 TABLE-5) # OF CONDUCTORSPER CONDUIT CONDUITSIZE NOMINAL INTERNAL AREAOF CONDUIT IN SQ.INCH(NEC CHAPTER-9 TABLE-4) CONDUIT/WIREFILL PERCENT FILL FACTOR(NEC 2014 TABLE310.15(B)(3)(a)) AMBIENT TEMP. IN DEGREECELCIUS TEMP.ADDER(NEC 2014 Table310.15(B)(3)(c)) TOTALTEMP INDEGREECELCIUS TEMP CORR. FACTOR(NEC-2014TABLE-310.15(B)(2)(a)) CONDUCTORRATING IN AMPERE(NEC-2014TABLE-310.15(B)(16)) DERATEDCURRENTRATING INAMPERE OCPD(NEC-2014ARTICLE-690.8 ) JUNCTION BOX TO INVERTER 10 AWG 0.0211 4 3/4"EMT 0.533 15.83%0.8 32 22 54 0.76 40 24.32 20A INVERTER TO POINT OF INTERCONNECTION 8 AWG 0.0366 3 3/4"EMT 0.533 20.60%1 32 0 32 0.96 55 52.80 40A INVERTER SPECIFICATION MAKE SOLAREDGE SE7600H-US (HD-WAVE) AC CAPACITY 7.6 OUTPUT POWER 7.6 PHASE 1 VOLTS 240 V OUTPUT CURRENT 32 A INTERCONNECTION TYPE PRIMARY INTERCONNECTION GGGG GGGG GGGG GGGG GGGG GGGG IRONRIDGE FLASHFOOT 2 (E) COMPOSITE SHINGLE (E) RAFTERS SOLAR MODULE IRONRIDGE XR-100 RAIL SIDE VIEW FLASHING 3 1/2" x 5/16 WITH 2.5 MINLAG SCREW EMBEDMENT TOP VIEW FRONT VIEW PV MODULE FRAME IRONRIDGE RAIL IRONRIDGE CAMO END CLAMP PV MODULE FRAME IRONRIDGE RAILIRONRIDGE CAMO END CLAMP PAGE SIZEJOB NUMBER B SITE NUMBER DRAWING NUMBER SCALE DATEDESCRIPTIONREVREVISION HISTORYREVDRWDRWCHKDRW PROJECT ADDRESS 20998 JUNCO TRAIL,LAKEVILLE, MN 55044 0 DRAFT REVIEW DRAWING TITLE PROJECT OWNER CONTRACTOR: 12/21/20SK TEL. NO. 1-800-467-4562 AHJ APN. MIKE JORDAN - 15485 UTILITY COMPANY 226481104080 EMPIRE SOLARGROUP WWW.EMPIRESOLARGROUP.COM 1 COMMENTS INCORPORATED 01/04/20DG LAKEVILLE 2 COMMENTS INCORPORATED 01/06/21AP PV-05 MOUNTING DETAILS &BOM N.T.S. ATTACHMENT TYPE: IRONRIDGE FLASHFOOT 2 WITH IRONRIDGE XR-100 RAILS MODULE WEIGHT: 48 LBS MODULE DIMENSIONS: 5.31' X 3.66' MODULE WEIGHT/ SQ. FOOT: 2.36 LBS TOTAL NO. OF MODULES: 22 TOTAL MODULE WEIGHT: 1056 LBS ATTACHMENT DETAILS(N.T.S.)1 1 4 (E) 200A MAIN PANEL (N) INVERTER (N) PHOTOVOLTAIC SYSTEM UTILITY DISCONNECT SWITCH TOARRAY 6 DUAL POWER SUPPLY PHOTOVOLTAIC AC DISCONNECT OPERATING CURRENT 32 AMPSOPERATING VOLTAGE 240 VOLTS LABEL-1: LABEL-2: WARNING-ELECTRIC SHOCK HAZARD DO NOT TOUCH TERMINALS TERMINALS ON BOTH LINE AND LOAD SIDE MAY BE ENERGIZED IN THE OPEN POSITION LABEL-5: LABELS TO BE BAKE LITE RED WITH WHITE LETTER ANDFASTENED BY BEING BOLTED OR RIVETED IN PLACE WARNING: PHOTOVOLTAICPOWER SOURCE LABEL-6: LABEL 6 IS REFLECTIVE WEATHER RESISTENT STICKER TO BE PLACED ON ALL INTERIOR AND EXTERIOR DC CONDUIT, RACEWAYS, ENCLOSURES, AND CABLE ASSEMBLIES EVERY 10', WITHIN 1' OF TURNS OR BENDS, AND1' ABOVE AND BELOW ALL PENETRATIONS ON DC CONDUIT. REQUIRED SIGNAGE: 2017 NEC CODES, ARTICLE 690 PHOTOVOLTAIC DC DISCONNECT LABEL-3: INVERTER-1 OPERATING CURRENT OPERATING VOLTAGEMAX SYSTEM VOLTAGE SHORT CIRCUIT CURRENT PHOTOVOLTAIC SYSTEM AC DISCONNECT 20 AMPS 400 VOLTS480 VOLTS 20 AMPS WARNING: INVERTER OUTPUT CONNECTION;DO NOT RELOCATE THIS OVERCURRENT DEVICE LABEL-7: LABEL-8: PHOTOVOLTAIC SYSTEM DEDICATED KWH METER LABEL-9: PHOTOVOLTAIC POWER SOURCE BREAKER ARE BACKFEEDING DO NOT RELOCATE LABEL- 10: SOLAR PV SYSTEM EQUIPPED WITHRAPID SHUTDOWN TURN RAPID SHUTDOWN SWITCH TO THE "OFF"POSITION TO SHUT DOWN PV SYSTEM AND REDUCE SHOCKHAZARD IN THE ARRAY 4 2 1 7 9 LABEL-4: WARNING-ELECTRIC SHOCK HAZARD IF A GROUND FAULT IS INDICATED THEN THE NORMALLY GROUNDED CONDUCTORS MAY BE ENERGIZED AND UNGROUNDED 3 5 10 DETAIL 1: LOCATION OF MAIN SERVICE PANEL MOUNTED ON INTERIOR SOUTH EAST WALL OF THE HOUSE AND UTILITY METER, UTILITY DISCONNECT, PV PRODUCTION METER AND INVERTER ON EXTERIOR SOUTH EAST WALL OF THE HOUSE. (E) UTILITY METER (N) PV PRODUCTION METER PAGE SIZEJOB NUMBER B SITE NUMBER DRAWING NUMBER SCALE DATEDESCRIPTIONREVREVISION HISTORYDRWCHK PROJECT ADDRESS 20998 JUNCO TRAIL,LAKEVILLE, MN 55044 0 DRAFT REVIEW DRAWING TITLE PROJECT OWNER CONTRACTOR: 12/21/20SK TEL. NO. 1-800-467-4562 AHJ APN. MIKE JORDAN - 15485 UTILITY COMPANY 226481104080 EMPIRE SOLARGROUP WWW.EMPIRESOLARGROUP.COM 1 COMMENTS INCORPORATED 01/04/20DG LAKEVILLE 2 COMMENTS INCORPORATED 01/06/21AP PV-6.1 LABELS N.T.S. PAGE SIZEJOB NUMBER B SITE NUMBER DRAWING NUMBER SCALE DATEDESCRIPTIONREVREVISION HISTORYDRWCHK PROJECT ADDRESS 20998 JUNCO TRAIL,LAKEVILLE, MN 55044 0 DRAFT REVIEW DRAWING TITLE PROJECT OWNER CONTRACTOR: 12/21/20SK TEL. NO. 1-800-467-4562 AHJ APN. MIKE JORDAN - 15485 UTILITY COMPANY 226481104080 EMPIRE SOLARGROUP WWW.EMPIRESOLARGROUP.COM 1 COMMENTS INCORPORATED 01/04/20DG LAKEVILLE 2 COMMENTS INCORPORATED 01/06/21AP PV-6.2 PLACARD N.T.S. PV ARRAY ON ROOF N ES W CAUTION POWER TO THIS BUILDING IS ALSO SUPPLIED FROM THE FOLLOWING SOURCES WITH DISCONNECTS LOCATED AS SHOWN: 20998 JUNCO TRL., LAKEVILLE , MN 55044 UTILITY METER(EXTERIOR)MAIN SERVICE PANEL(INTERIOR)UTILITY METER(EXTERIOR)UTILITY METER(EXTERIOR)AC DISCONNECT BOX(EXTERIOR) INVERTER(EXTERIOR)PV PROUCTION METER(EXTERIOR)INVERTER(EXTERIOR) PAGE SIZEJOB NUMBER B SITE NUMBER DRAWING NUMBER SCALE DATEDESCRIPTIONREVREVISION HISTORYDRWCHK PROJECT ADDRESS 20998 JUNCO TRAIL,LAKEVILLE, MN 55044 0 DRAFT REVIEW DRAWING TITLE PROJECT OWNER CONTRACTOR: 12/21/20SK TEL. NO. 1-800-467-4562 AHJ APN. MIKE JORDAN - 15485 UTILITY COMPANY 226481104080 EMPIRE SOLARGROUP WWW.EMPIRESOLARGROUP.COM 1 COMMENTS INCORPORATED 01/04/20DG LAKEVILLE 2 COMMENTS INCORPORATED 01/06/21AP PV-6.3 PLACARD N.T.S. PV ARRAY ON ROOF N ES W CAUTION POWER TO THIS BUILDING IS ALSO SUPPLIED FROM THE FOLLOWING SOURCES WITH DISCONNECTS LOCATED AS SHOWN: 20998 JUNCO TRL., LAKEVILLE , MN 55044 UTILITY METER(EXTERIOR)MAIN SERVICE PANEL(INTERIOR)UTILITY METER(EXTERIOR)UTILITY METER(EXTERIOR)AC DISCONNECT BOX(EXTERIOR) INVERTER(EXTERIOR)PV PROUCTION METER(EXTERIOR)INVERTER(EXTERIOR) PAGE SIZEJOB NUMBER B SITE NUMBER DRAWING NUMBER SCALE DATEDESCRIPTIONREVREVISION HISTORYREVDRWDRWCHKDRW PROJECT ADDRESS 20998 JUNCO TRAIL,LAKEVILLE, MN 55044 0 DRAFT REVIEW DRAWING TITLE PROJECT OWNER CONTRACTOR: 12/21/20SK TEL. NO. 1-800-467-4562 AHJ APN. MIKE JORDAN - 15485 UTILITY COMPANY 226481104080 EMPIRE SOLARGROUP WWW.EMPIRESOLARGROUP.COM 1 COMMENTS INCORPORATED 01/04/20DG LAKEVILLE 2 COMMENTS INCORPORATED 01/06/21AP PV-07 INTERCONNECTIONPHOTO N.T.S. PAGE SIZEJOB NUMBER B SITE NUMBER DRAWING NUMBER SCALE DATEDESCRIPTIONREVREVISION HISTORYREVDRWDRWCHKDRW PROJECT ADDRESS 20998 JUNCO TRAIL,LAKEVILLE, MN 55044 0 DRAFT REVIEW DRAWING TITLE PROJECT OWNER CONTRACTOR: 12/21/20SK TEL. NO. 1-800-467-4562 AHJ APN. MIKE JORDAN - 15485 UTILITY COMPANY 226481104080 EMPIRE SOLARGROUP WWW.EMPIRESOLARGROUP.COM 1 COMMENTS INCORPORATED 01/04/20DG LAKEVILLE 2 COMMENTS INCORPORATED 01/06/21AP FL-01 BOM N.T.S. BILL OF MATERIAL EQUIPMENT MAKE QUANTITY MODULE (N)SOLARIA POWERXT-365R-PD 22 INVERTER (N)SOLAREDGE SE7600H-US (240V)1 PV BREAKERS (N)40A/2P 1 END CLAMPS MODULE END CLAMP STANDARD 12 MID CLAMPS MODULE MIDDLE CLAMP SET STANDARD(INTEGRATED GROUNDING)38 MOUNTING POINTS IRONRIDGE FLASH FOOT 2 44 MOUNTING RAILS IRONRIDGE XR100 16 UTILITY DISCONNECT PV SYSTEM UTILITY DISCONNECT SW(VISIBLE OPEN, NO FUSES) SQUARE D 60A, 2P,240VAC NEMA 3R 1 OPTIMIZERS SOLAREDGE POWER OPTIMIZERS P400 22 PV PRODUCTION METER(N)PV METER 1-PHASE, 3-WIRED 1 PAGE SIZEJOB NUMBER B SITE NUMBER DRAWING NUMBER SCALE DATEDESCRIPTIONREVREVISION HISTORYREVDRWDRWCHKDRW PROJECT ADDRESS 20998 JUNCO TRAIL,LAKEVILLE, MN 55044 0 DRAFT REVIEW DRAWING TITLE PROJECT OWNER CONTRACTOR: 12/21/20SK TEL. NO. 1-800-467-4562 AHJ APN. MIKE JORDAN - 15485 UTILITY COMPANY 226481104080 EMPIRE SOLARGROUP WWW.EMPIRESOLARGROUP.COM 1 COMMENTS INCORPORATED 01/04/20DG LAKEVILLE 2 COMMENTS INCORPORATED 01/06/21AP FL-02 STRING PLAN N.T.S. STRING-1 STRING-2 PAGE SIZEJOB NUMBER B SITE NUMBER DRAWING NUMBER SCALE DATEDESCRIPTIONREVREVISION HISTORYREVDRWDRWCHKDRW PROJECT ADDRESS 20998 JUNCO TRAIL,LAKEVILLE, MN 55044 0 DRAFT REVIEW DRAWING TITLE PROJECT OWNER CONTRACTOR: 12/21/20SK TEL. NO. 1-800-467-4562 AHJ APN. MIKE JORDAN - 15485 UTILITY COMPANY 226481104080 EMPIRE SOLARGROUP WWW.EMPIRESOLARGROUP.COM 1 COMMENTS INCORPORATED 01/04/20DG LAKEVILLE 2 COMMENTS INCORPORATED 01/06/21AP FL-03 ASBUILT N.T.S. DRAW IN FINAL LOCATION OF EQUIPMENT 1.PANELS2.BRANCHS3.INVERTER(S)4.MAIN PANEL5.SUBPANEL (IF PRESENT)6.DISCONNECT(S) (IF PRESENT)7.ROOF ELECTRICAL PENETRATION8.CONDUIT ROUTES 9.COMMUNICATION WIRE RUNS 10.MONITORING EQUIPMENT PAGE SIZEJOB NUMBER B SITE NUMBER DRAWING NUMBER SCALE DATEDESCRIPTIONREVREVISION HISTORYREVDRWDRWCHKDRW PROJECT ADDRESS 20998 JUNCO TRAIL,LAKEVILLE, MN 55044 0 DRAFT REVIEW DRAWING TITLE PROJECT OWNER CONTRACTOR: 12/21/20SK TEL. NO. 1-800-467-4562 AHJ APN. MIKE JORDAN - 15485 UTILITY COMPANY 226481104080 EMPIRE SOLARGROUP WWW.EMPIRESOLARGROUP.COM 1 COMMENTS INCORPORATED 01/04/20DG LAKEVILLE 2 COMMENTS INCORPORATED 01/06/21AP FL-04 OPTIMIZERMAP N.T.S. Inverter ZigBee Sticker Model Serial # #of Modules per Branch MAPPING INSTRUCTIONS: 1.REMOVE THE 'SQUARE' OPTIMIZER OR ENPHASE STICKER ANDPLACE NEATLY ON THE APPROPRIATE NUMBERED SPACE.2.WRITE THE CORRESPONDING NUMBER ON THE APPROPRIATEPANEL WITHIN THE ARRAY. 3.ATTACH THE SQUARE INVERTER STICKER (AND ZIGBEE STICKER IF REQ'D) IN SPACE PROVIDED. Branch Information String 1 Panel 1 - 11 String 2 Panel 12 - 22 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 MODULE ALLOCATION ROOF PLANE A B C D E AZIMUTH 224 134 TILT 30 30 # OF MODULES 16 6 PAGE SIZEJOB NUMBER B SITE NUMBER DRAWING NUMBER SCALE DATEDESCRIPTIONREVREVISION HISTORYREVDRWDRWCHKDRW PROJECT ADDRESS 20998 JUNCO TRAIL,LAKEVILLE, MN 55044 0 DRAFT REVIEW DRAWING TITLE PROJECT OWNER CONTRACTOR: 12/21/20SK TEL. NO. 1-800-467-4562 AHJ APN. MIKE JORDAN - 15485 UTILITY COMPANY 226481104080 EMPIRE SOLARGROUP WWW.EMPIRESOLARGROUP.COM 1 COMMENTS INCORPORATED 01/04/20DG LAKEVILLE 2 COMMENTS INCORPORATED 01/06/21AP FL-05 JOB CHECKSHEET N.T.S. CREW LEAD: __________________________________ DATE: ________________________________________ Y N PHOTO CHECKLIST DONE (SEE RIGHT)? Y N PERMIT LEFT FOR INSPECTION?WHERE? _______________ Y N JOBSITE CLEANED UP? Y N CONDUIT PAINTED? Y N STICKERS & PLACARDS INSTALLED? Y N DAMAGE REPAIRS NEEDED? Y N JOB PHOTOS TAKEN Y N OPTIMIZER/MICROINVERTER MAP FILLED OUT? Y N CLIENT WALK THROUGH COMPLETED? Y N YARD SIGN INSTALLED? Y N WAS SYSTEM LEFT ON? INVERTER INFORMATION STRING VOLTAGE 1 2 3 4 BRAND: MODEL: LOCATION: SERIAL: 1 2 3 4 5 6 BRAND: MODEL: LOCATION: SERIAL: 1 2 3 4 5 6 BRAND: MODEL: LOCATION: SERIAL: 1 2 3 4 5 6 BRAND: MODEL: LOCATION: SERIAL: 1 2 3 4 5 6 PHOTO CHECKLIST INVERTER WIRING SERIAL NUMBERS STRING DIAGRAM MOUNTING CONDUIT CONNECTIONS LABELING MAIN PANEL BREAKER TIE IN LOCATION WIRING CONDUIT CONNECTION LABELING GEC DISCONNECT WIRING MOUNTING (CLEARANCES) CONDUIT CONNECTION LABELING CONDUIT (SHOW FULL RUN) ATTIC CONDUIT EXTERIOR CONDUIT JUNCTION BOXES WIRING WEEP HOLE CONDUIT CONNECTION LABELING FLASHING UP CLOSE STEPPED BACK CONDUIT PENETRATION BEFORE SEALANT AFTER SEALANT COMBINER BOXES WIRING WEEP HOLE CONDUIT CONNECTION LABELING ROOFING MATERIAL UNDER ARRAY BEFORE MODULES AROUND ARRAY AFTER MODULES RAIL MOUNTING HARDWARE STEP BACK VIEW ARRAY WIRING HOME RUNS JUMPERS ATTIC PENETRATIONS GROUNDING WIRE OPTIMIZERS FINISHED ARRAY INVERTER OTHER ITEMS NEEDED? PAGE SIZEJOB NUMBER B SITE NUMBER DRAWING NUMBER SCALE DATEDESCRIPTIONREVREVISION HISTORYREVDRWDRWCHKDRW PROJECT ADDRESS 20998 JUNCO TRAIL,LAKEVILLE, MN 55044 0 DRAFT REVIEW DRAWING TITLE PROJECT OWNER CONTRACTOR: 12/21/20SK TEL. NO. 1-800-467-4562 AHJ APN. MIKE JORDAN - 15485 UTILITY COMPANY 226481104080 EMPIRE SOLARGROUP WWW.EMPIRESOLARGROUP.COM 1 COMMENTS INCORPORATED 01/04/20DG LAKEVILLE 2 COMMENTS INCORPORATED 01/06/21AP PV-08.1 MODULEDATASHEET N.T.S. PAGE SIZEJOB NUMBER B SITE NUMBER DRAWING NUMBER SCALE DATEDESCRIPTIONREVREVISION HISTORYREVDRWDRWCHKDRW PROJECT ADDRESS 20998 JUNCO TRAIL,LAKEVILLE, MN 55044 0 DRAFT REVIEW DRAWING TITLE PROJECT OWNER CONTRACTOR: 12/21/20SK TEL. NO. 1-800-467-4562 AHJ APN. MIKE JORDAN - 15485 UTILITY COMPANY 226481104080 EMPIRE SOLARGROUP WWW.EMPIRESOLARGROUP.COM 1 COMMENTS INCORPORATED 01/04/20DG LAKEVILLE 2 COMMENTS INCORPORATED 01/06/21AP PV-08.2 N.T.S. INVERTERDATASHEET PAGE SIZEJOB NUMBER B SITE NUMBER DRAWING NUMBER SCALE DATEDESCRIPTIONREVREVISION HISTORYREVDRWDRWCHKDRW PROJECT ADDRESS 20998 JUNCO TRAIL,LAKEVILLE, MN 55044 0 DRAFT REVIEW DRAWING TITLE PROJECT OWNER CONTRACTOR: 12/21/20SK TEL. NO. 1-800-467-4562 AHJ APN. MIKE JORDAN - 15485 UTILITY COMPANY 226481104080 EMPIRE SOLARGROUP WWW.EMPIRESOLARGROUP.COM 1 COMMENTS INCORPORATED 01/04/20DG LAKEVILLE 2 COMMENTS INCORPORATED 01/06/21AP PV-08.3 N.T.S. INVERTERDATASHEET PAGE SIZEJOB NUMBER B SITE NUMBER DRAWING NUMBER SCALE DATEDESCRIPTIONREVREVISION HISTORYREVDRWDRWCHKDRW PROJECT ADDRESS 20998 JUNCO TRAIL,LAKEVILLE, MN 55044 0 DRAFT REVIEW DRAWING TITLE PROJECT OWNER CONTRACTOR: 12/21/20SK TEL. NO. 1-800-467-4562 AHJ APN. MIKE JORDAN - 15485 UTILITY COMPANY 226481104080 EMPIRE SOLARGROUP WWW.EMPIRESOLARGROUP.COM 1 COMMENTS INCORPORATED 01/04/20DG LAKEVILLE 2 COMMENTS INCORPORATED 01/06/21AP PV-08.4 RACKINGDATASHEET N.T.S. PAGE SIZEJOB NUMBER B SITE NUMBER DRAWING NUMBER SCALE DATEDESCRIPTIONREVREVISION HISTORYREVDRWDRWCHKDRW PROJECT ADDRESS 20998 JUNCO TRAIL,LAKEVILLE, MN 55044 0 DRAFT REVIEW DRAWING TITLE PROJECT OWNER CONTRACTOR: 12/21/20SK TEL. NO. 1-800-467-4562 AHJ APN. MIKE JORDAN - 15485 UTILITY COMPANY 226481104080 EMPIRE SOLARGROUP WWW.EMPIRESOLARGROUP.COM 1 COMMENTS INCORPORATED 01/04/20DG LAKEVILLE 2 COMMENTS INCORPORATED 01/06/21AP PV-08.5 ATTACHMENTDATASHEET N.T.S.