Loading...
HomeMy WebLinkAboutLA187320 - 20295 Hampton Ave update 1.6.21 Wyssling Consulting 76 North Meadowbrook Drive Alpine, UT 84004 Scott E. Wyssling, PE, PP, CME office (201) 874-3483 swyssling@wysslingconsulting.com December 29, 2020 Everlight Solar Construction PO Box 930550 Verona, WI 53593 Re: Engineering Services Turner Residence 20295 Hampton Avenue, Lakeville, MN 12.604 kW System To Whom It May Concern: Pursuant to your request, we have reviewed the following information regarding solar panel installation on the roof of the above referenced home: 1. Site Visit/Verification Form prepared by an Everlight Solar representative identifying specific site information including size and spacing of rafters for the existing roof structure. 2. Design drawings of the proposed system including a site plan, roof plan and connection details for the solar panels. This information was prepared by Everlight Solar and will be utilized for approval and construction of the proposed system. 3. Photographs of the interior and exterior of the roof system identifying existing structural members and their conditions. Based on the above information we have evaluated the structural capacity of the existing roof system to support the additional loads imposed by the solar panels and have the following comments related to our review and evaluation: Description of Residence: The existing residence is typical wood framing construction with the roof system consisting of truss system with all chords constructed of 2 x 4 dimensional lumber at 24” on center. The attic space is unfinished and photos indicate that there was free access to visually inspect the size and condition of the roof rafters. All wood material utilized for the roof system is assumed to be Doug-Fir #2 or better with standard construction components. The existing roofing material consists of composite asphalt shingles. Photos of the dwelling also indicate that there is a permanent foundation. A. Loading Criteria Used • 115 MPH wind loading based on ASCE 7-16 Exposure Category “C” at a slope of 35 degrees • 7 PSF = Dead Load roofing/framing Live Load = 20 PSF Snow Load = 50 PSF • 3 PSF = Dead Load solar panels/mounting hardware Total Dead Load =10 PSF The above values are within acceptable limits of recognized industry standards for similar structures in accordance with the Minnesota Residential Code (2018 IRC). Analysis performed of the existing roof structure utilizing the above loading criteria indicates that the existing rafters will support the additional panel loading without damage, if installed correctly. Page 2 of 2 B. Solar Panel Anchorage 1. The solar panels shall be mounted in accordance with the most recent “IronRidge Solar Installation Manual”, which can be found on the IronRidge Solar website (http://ironridgesolar.com/). If during solar panel installation, the roof framing members appear unstable or deflect non-uniformly, our office should be notified before proceeding with the installation. 2. Maximum allowable pullout per lag screw is 235 lbs/inch of penetration as identified in the National Design Standards (NDS) of timber construction specifications for Doug-Fir (North Lumber) assumed. Based on our evaluation, the pullout value, utilizing a penetration depth of 2 ½”, is less than what is allowable per connection and therefore is adequate. Based on the variable factors for the existing roof framing and installation tolerances, using a thread depth of 2 ½” with a minimum size of 5/16” lag screw per attachment point for panel anchor mounts should be adequate with a sufficient factor of safety. 3. Considering the roof slopes, the size, spacing, condition of roof, the panel supports shall be placed no greater than 48” o/c. 4. Panel supports connections shall be staggered to distribute load to adjacent trusses. Based on the above evaluation, it is the opinion of this office that with appropriate panel anchors being utilized the roof system will adequately support the additional loading imposed by the solar panels. This evaluation is in conformance with the Minnesota Residential Code (2018 IRC), current industry standards, and is based on information supplied to us at the time of this report. Should you have any questions regarding the above or if you require further information do not hesitate to contact me. Very truly yours, Scott E. Wyssling, PE Minnesota License No. 57927 SITE INFORMATION: Kristin Turner 20295 Hampton Ave, Lakeville, MN 55044 MAX CONTINUOUS AC SYSTEM SIZE: 12.604 kW AC DC SYSTEM SIZE: 15.18 kW DC Lat, Long: 44.6551258 , -93.2299848999999 (46) Silfab SIL-330 NL PV MODULES (23) AP Systems YC600 INVERTERSCONTRACTOR INFORMATION:Everlight Solar ConstructionPO Box 930550Verona, WI 53593License# DCQ-111802116833.786.4387 ext. 701Xcel Energy MNPV01 COVER PAGE PV02 PROPERTY PLAN PV03 ROOF PLAN PV04 ROOF ATTACHMENTS + BOM PV05 MOUNTING DETAIL PV06 ELECTRICAL DIAGRAM PV07 LABELS PV08 PLACARD PV09 SITE PHOTOS DATE: December 23, 2020 PV01 PAGE: SHEET NAME: COVER PAGE DRAWN BY: SoloCAD GENERAL NOTES: 1.INSTALLATION OF SOLAR PHOTOVOLTAIC SYSTEM SHALL BE IN ACCORDANCE WITH NEC ARTICLE 690, AND ALL OTHER APPLICABLE NEC CODES WHERE NOTED OR EXISTING. 2.PROPER ACCESS AND WORKING CLEARANCE AROUND EXISTING AND PROPOSED ELECTRICAL EQUIPMENT WILL COMPLY WITH NEC ARTICLE 110. 3.ALL WIRES, INCLUDING THE GROUNDING ELECTRODE CONDUCTOR SHALL BE PROTECTED FROM PHYSICAL DAMAGE IN ACCORDANCE WITH NEC ARTICLE 250 4.THE PV MODULES ARE CONSIDERED NON-COMBUSTIBLE; THIS SYSTEM IS UTILITY INTERACTIVE PER UL 1741 AND DOES NOT INCLUDE STORAGE BATTERIES OR OTHER ALTERNATIVE STORAGE SOURCES. 5.ALL DC WIRES SHALL BE SIZED ACCORDING TO [NEC 690.8] 6.DC CONDUCTORS SHALL BE WITHIN PROTECTED RACEWAYS IN ACCORDANCE WITH [NEC 690.31] 7.ALL SIGNAGE TO BE PLACED IN ACCORDANCE WITH LOCAL JURISDICTIONAL BUILDING CODE. APPLICABLE GOVERNING CODES: DESCRIPTION OF DESIGN: INSTALLATION OF GRID -TIED, UTILITY INTERACTIVE PHOTOVOLTAIC SYSTEM AERIAL VIEW:STREET VIEW:SHEET INDEX: EQUIPMENT: MAX CONTINUOUS AC SYSTEM SIZE: 12.604 kW AC DC SYSTEM SIZE: 15.18 kW DC (46) Silfab SIL-330 NL PV MODULES (23) AP Systems YC600 INVERTERS RACKING: SolarRoofHook - 48" O.C. SITE SPECIFICATIONS: OCCUPANCY: R-3 ZONING: RESIDENTIAL2020 NEC 2020 MRC 2020 MFC 2020 MBC SITE INFORMATION: Kristin Turner 20295 Hampton Ave, Lakeville, MN 55044 MAX CONTINUOUS AC SYSTEM SIZE: 12.604 kW AC DC SYSTEM SIZE: 15.18 kW DC Lat, Long: 44.6551258 , -93.2299848999999 (46) Silfab SIL-330 NL PV MODULES (23) AP Systems YC600 INVERTERSMMSPACINVCONTRACTOR INFORMATION:Everlight Solar ConstructionPO Box 930550Verona, WI 53593License# DCQ-111802116833.786.4387 ext. 701Xcel Energy MNDATE: December 23, 2020 PV02 PAGE: SHEET NAME: PROPERTY PLAN DRAWN BY: SoloCAD SCALE: EQUIPMENT LEGEND: INVERTER VISIBLE, LOCKABLE, LABELED AC DISCONNECT METER SOCKET (FOR UTILITY PV METER) UTILITY METER MAIN SERVICE PANEL LC LOAD CENTER FIRE ACCESS PATHWAY (3' TYP) C INV PV AC MSP M COMBINER BOX PROPERTY LINE MP3 PITCH: 35° AZIMUTH: 160°20295 Hampton AveMP2 PITCH: 35° AZIMUTH: 250°FRONT OF HOMEMP1 PITCH: 35° AZIMUTH: 70° BATT BATTERY(IES) VISIBLE, LOCKABLE, LABELED AC DISCONNECT LOCATED WITHIN 10' OF UTILITY METER1" = 13.39' 84'-0" 128'-2"NO CLEARANCE ISSUES AROUND HOME OR SOLAR ARRAY 24/7 UNESCORTED KEYLESS ACCESS SHALL BE PROVIDED TO XCEL ENERGY FOR ALL XCEL ENERGY OWNED METERS AND DISCONNECTS. ALL PV EQUIPMENT INSTALLED WITHIN 10' OF UTILITY METER CASE# 04249303 SOLAR ARRAY INVERTERS BEHIND PANELS SITE INFORMATION: Kristin Turner 20295 Hampton Ave, Lakeville, MN 55044 MAX CONTINUOUS AC SYSTEM SIZE: 12.604 kW AC DC SYSTEM SIZE: 15.18 kW DC Lat, Long: 44.6551258 , -93.2299848999999 (46) Silfab SIL-330 NL PV MODULES (23) AP Systems YC600 INVERTERSMMSPACINVCONTRACTOR INFORMATION:Everlight Solar ConstructionPO Box 930550Verona, WI 53593License# DCQ-111802116833.786.4387 ext. 701Xcel Energy MNMP3 PITCH: 35° AZIMUTH: 160° DATE: December 23, 2020 PV03 PAGE: SHEET NAME: ROOF PLAN DRAWN BY: SoloCAD EQUIPMENT LEGEND: INVERTER VISIBLE, LOCKABLE, LABELED AC DISCONNECT METER SOCKET (FOR UTILITY PV METER) UTILITY METER MAIN SERVICE PANEL LC LOAD CENTER FIRE ACCESS PATHWAY (3' TYP) C INV PV AC MSP M COMBINER BOX FRONT OF HOMEMP2 PITCH: 35° AZIMUTH: 250° MP1 PITCH: 35° AZIMUTH: 70° BATT BATTERY(IES) VISIBLE, LOCKABLE, LABELED AC DISCONNECT LOCATED WITHIN 10' OF UTILITY METER 3'-0" TYP 1'-6" TYP. MMSPACINV SITE INFORMATION: Kristin Turner 20295 Hampton Ave, Lakeville, MN 55044 MAX CONTINUOUS AC SYSTEM SIZE: 12.604 kW AC DC SYSTEM SIZE: 15.18 kW DC Lat, Long: 44.6551258 , -93.2299848999999 (46) Silfab SIL-330 NL PV MODULES (23) AP Systems YC600 INVERTERSCONTRACTOR INFORMATION:Everlight Solar ConstructionPO Box 930550Verona, WI 53593License# DCQ-111802116833.786.4387 ext. 701EQUIPMENT INFORMATION: RAIL MANUFACTURER IronRidge RAIL PART NUMBER XR-10 ATTACHMENTS Quickbolt ATTACHMENT QTY 78 MIDCLAMP QTY 82 ENDCLAMP QTY 20 SPLICE QTY 14 ROOF INFO: ROOF TYPE asphalt_shingle ROOF FRAMING traditional_framing RAFTER/TOP CHORD SIZE 2x4 RAFTER/TOP CHORD SPACING 24 ATTACHMENT SPACING 48Xcel Energy MNDATE: December 23, 2020 PV04 PAGE: SHEET NAME: ROOF ATTACHMENTS + BOM DRAWN BY: SoloCAD ROOF ATTACHMENT COUNT:78 PV MODULE COUNT:46 ARRAY AREA:MODULE COUNT * 18.06ft² = 830.76 ROOF AREA:2395 ft² PERCENT OF ROOF COVERED:35% ARRAY WEIGHT:MODULE COUNT * 50lbs = 2300 DISTRIBUTED LOAD:ARRAY LBS/ATTACHMENTS = 29.49 POINT LOAD: (lbs/ft²)(ARRAY) WEIGHT/AREA = 2.77 lbs/ft² PHOTOVOLTAIC ARRAY STRUCTURAL CRITERIA: RAIL L-FOOT/ATTACHMENT BRACKET (E) ROOF FRAMING 5/16" STAINLESS STEEL LAG-BOLT WITH 2-1/2" MIN. EMBEDMENT AND FLAT WASHER FLASHING PV MODULE (E) COMP SHINGLE ROOF (1 LAYER) RAIL END CLAMP PV MODULE MID CLAMP PV MODULE 4" 2 1 2" MIN. DEPTH RAIL RAIL FLASHING & LAG-BOLT 2'-8" MIN - 3'-10" MAX 3 RAIL PV MODULE " MAX."1'-8" MAX. 21 FRONT VIEW 10" MIN - 1'-4" MAX2'-8" MIN - 3'-10" MAX 10" MIN - 1'-4" MAX SIDE VIEW (E) RAFTER/TOP CHORDS (E) RAFTER/TOP CHORD DETAIL, MOUNTING AND FLASHING END CLAMP DETAILS MID CLAMP DETAILS 3 21 SITE INFORMATION: Kristin Turner 20295 Hampton Ave, Lakeville, MN 55044 MAX CONTINUOUS AC SYSTEM SIZE: 12.604 kW AC DC SYSTEM SIZE: 15.18 kW DC Lat, Long: 44.6551258 , -93.2299848999999 (46) Silfab SIL-330 NL PV MODULES (23) AP Systems YC600 INVERTERSCONTRACTOR INFORMATION:Everlight Solar ConstructionPO Box 930550Verona, WI 53593License# DCQ-111802116833.786.4387 ext. 701EQUIPMENT INFORMATION: RAIL MANUFACTURER IronRidge RAIL PART NUMBER XR-10 ATTACHMENTS Quickbolt ATTACHMENT QTY 78 MIDCLAMP QTY 82 ENDCLAMP QTY 20 SPLICE QTY 14 ROOF INFO: ROOF TYPE asphalt_shingle ROOF FRAMING traditional_framing RAFTER/TOP CHORD SIZE 2x4 RAFTER/TOP CHORD SPACING 24 ATTACHMENT SPACING 48Xcel Energy MNDATE: December 23, 2020 PV05 PAGE: SHEET NAME: MOUNTING DETAIL DRAWN BY: SoloCAD ROOF ATTACHMENT COUNT:78 PV MODULE COUNT:46 ARRAY AREA:MODULE COUNT * 18.06ft² = 830.76 ROOF AREA:2395 ft² PERCENT OF ROOF COVERED:35% ARRAY WEIGHT:MODULE COUNT * 50lbs = 2300 DISTRIBUTED LOAD:ARRAY LBS/ATTACHMENTS = 29.49 POINT LOAD: (lbs/ft²)(ARRAY) WEIGHT/AREA = 2.77 lbs/ft² PHOTOVOLTAIC ARRAY STRUCTURAL CRITERIA: (N) 70A FUSES 4 PV AC DISCONNECT FUSED, AIC 10kA VISIBLE, LOCKABLE, LABELED, OPEN 100A, 240V, 2-POLE (E) LOADS N G SUPPLY SIDE CONNECTION: NEC 230.46, NEC 230.79, NEC 705.12(A) (E) MAIN BREAKER (E)GROUNDING ELECTRODE INTERCONNECTION NOTES 1. GROUND FAULT PROTECTION IN ACCORDANCE WITH [NEC 215.9] & [NEC 230.95] 2. SUPPLY SIDE INTERCONNECTION ACCORDING TO [NEC705.12(A)] WITH SERVICE ENTRANCE CONDUCTORS IN ACCORDANCE WITH [NEC 240.21(B)] DISCONNECT NOTES 1. DISCONNECTING SWITCHES SHALL BE WIRED SUCH THAT WHEN THE SWITCH IS OPENED THE CONDUCTORS REMAINING LIVE ARE CONNECTED TO THE TERMINALS MARKED “LINE SIDE” (TYPICALLY THE UPPER TERMINALS) 2. AC DISCONNECT MUST BE ACCESSIBLE TO QUALIFIED UTILITY PERSONNEL, BE LOCKABLE, AND BE A VISIBLE-BREAK SWITCH. 3. FUSED AC DISCONNECT TO BE USED. (E)MAIN SERVICE PANEL 4 N G AC COMBINER BOX SOLAR LOADS ONLY UL 1741 COMPLIANT (N) 100A (4) 20A-2P J-BOX AC DC AC DC STRING [3] AC DC AC DC STRING [4] J-BOX J-BOX 3 1 1 2 2 AC DC AC DC STRING [2] J-BOX1 2 AC DC AC DC STRING [1] J-BOX1 2 (E) 120/240 VAC TO UTILITY GRID (E)UTILITY METER SITE INFORMATION: Kristin Turner 20295 Hampton Ave, Lakeville, MN 55044 MAX CONTINUOUS AC SYSTEM SIZE: 12.604 kW AC DC SYSTEM SIZE: 15.18 kW DC Lat, Long: 44.6551258 , -93.2299848999999 (46) Silfab SIL-330 NL PV MODULES (23) AP Systems YC600 INVERTERSCONTRACTOR INFORMATION:Everlight Solar ConstructionPO Box 930550Verona, WI 53593License# DCQ-111802116833.786.4387 ext. 7011 2 3 4(1) 12-2 TC-ER, THWN-2, COPPER (OR CODE APPROVED EQUIVALENT) (1) 6 AWG BARE, COPPER (GROUND) (1) 10 AWG THWN-2, or THHN, or 10/2 NM-B COPPER - (POSITIVE) (1) 10 AWG THWN-2, or THHN, or 10/2 NM-B COPPER - (NEGATIVE) (1) 10 AWG THWN-2, or THHN, or 10/2 NM-B COPPER - (GROUND) (1) 3/4" LIQUID TIGHT OR EMT OR FMC (OR CODE APPROVED EQUIVALENT) (4) 10 AWG THHN/THWN-2, COPPER - (L1) (4) 10 AWG THHN/THWN-2 COPPER - (L2) (1) 8 AWG THHN/THWN-2 (GROUND) CONDUIT: 1" LIQUID TIGHT OR EMT (OR CODE APPROVED EQUIVALENT) (1) 4 AWG THWN-2 COPPER - (L1) (1) 4 AWG THWN-2 COPPER - (L2) (1) 4 AWG THWN-2 COPPER - (NEUTRAL) (1) 8 AWG THWN-2 COPPER - (GROUND) (1) CONDUIT: 1" LIQUID TIGHT OR EMT (OR CODE APPROVED EQUIVALENT) SERVICE EQUIPMENT & PV OCPD RATINGS MAIN BREAKER RATING 150A MAIN SERVICE BUS RATING 150A PV OCPD RATING 70A AC VOLTAGE 240V AC DISCONNECT RATING 100A STRINGS: STRING 1 14 PV MODULES STRING 2 14 PV MODULES STRING 3 14 PV MODULES STRING 4 4 PV MODULES Xcel Energy MNDATE: December 23, 2020 PV06 PAGE: SHEET NAME: ELECTRICAL DIAGRAM DRAWN BY: SoloCAD WIRE SCHEDULE EQUIPMENT SCHEDULE: TYPE:QTY:DESCRIPTION:RATING: MODULES:(46)Silfab SIL-330 NL 330 W INVERTERS:(23)AP Systems YC600 548 W AC DISCONNECT(S):(1)PV AC DISCONNECT, 240V, 2-POLE 100 A GROUNDING & GENERAL NOTES: 1. A SECOND FACILITY GROUNDING ELECTRODE IS NOT REQUIRED PER [NEC 690.47(C)(3)] 2. PV INVERTER IS UNGROUNDED, TRANSFORMER-LESS TYPE. 3. DC GEC AND AC EGC TO REMAIN UNSPLICED, OR SPLICED TO EXISTING ELECTRODE 4. ANY EXISTING WIRING INVOLVED WITH PV SYSTEM CONNECTION THAT IS FOUND TO BE INADEQUATE PER CODE SHALL BE CORRECTED PRIOR TO FINAL INSPECTION. 5. JUNCTION BOX QUANTITIES, AND PLACEMENT SUBJECT TO CHANGE IN THE FIELD - JUNCTION BOXES DEPICTED ON ELECTRICAL DIAGRAM REPRESENT WIRE TYPE TRANSITIONS. 6. AC DISCONNECT NOTED IN EQUIPMENT SCHEDULE OPTIONAL IF OTHER AC DISCONNECTING MEANS IS LOCATED WITHIN 10' OF SERVICE DISCONNECT. CASE# 04249303 DESIGN SHALL MEET NEC REQUIREMENTS 2' VARIES PV UTILITY AC DISCONNECT REFERENCE POINT OF APPLICABILITY MAXIMUM INPUT VOLTAGE 55V MAXIMUM INPUT CURRENT 12A X2 NOMINAL OUTPUT VOLTAGE 240V NOMINAL OUTPUT CURRENT 2.28A 1-PHASE 60HZ UL1741 LISTED AP Systems YC600 (240V) SPECS 240V RATED SERVICE MAIN PANEL LOCATED IN BASEMENT SITE INFORMATION: Kristin Turner 20295 Hampton Ave, Lakeville, MN 55044 MAX CONTINUOUS AC SYSTEM SIZE: 12.604 kW AC DC SYSTEM SIZE: 15.18 kW DC Lat, Long: 44.6551258 , -93.2299848999999 (46) Silfab SIL-330 NL PV MODULES (23) AP Systems YC600 INVERTERSCONTRACTOR INFORMATION:Everlight Solar ConstructionPO Box 930550Verona, WI 53593License# DCQ-111802116833.786.4387 ext. 701LABEL VALUES: DESCRIPTION VALUE: DC IMP:9.92 DC VMP:33.3 DC VOC:40.5 DC ISC:SEE DATASHEET DC SYSTEM SIZE (W):15180 AC OPERATING CURRENT:SEE DATASHEET AC VOLTAGE:240Xcel Energy MNDATE: December 23, 2020 PV07 PAGE: SHEET NAME: LABELS DRAWN BY: SoloCAD LABEL 3 AT POINT OF INTERCONNECTION, MARKED AT AC DISCONNECTING MEANS. [NEC 690.54, NEC 690.13 (B)] LABEL 4 AT POINT OF INTERCONNECTION FOR EQUIPMENT CONTAINING OVERCURRENT DEVICES IN CIRCUTS SUPPLYING POWER TO A BUSBAR OR CONDUCTOR SUPPLIED FORM MULTIPLE SOURCES, EACH SERVICE EQUIPMENT AND ALL ELECTRIC POWER PRODUCTION SOURCE LOCATIONS. [NEC 705.12(B)(3)] LABEL 5 PLACED ADJACENT TO THE BACK-FED BREAKER FROM THE INVERTER IF TIE IN CONSISTS OF LOAD SIDE CONNECTION TO BUSBAR. [NEC 705.12(D)(2)(3)(b)] *ELECTRICAL DIAGRAM SHOWN ABOVE IS FOR LABELING PURPOSES ONLY. NOT AN ACTUAL REPRESENATION OF EQUIPMENT AND CONNECTIONS TO BE INSTALLED. LABEL LOCATIONS PRESENTED MAY VERY DEPENDING ON TYPE OF INTERCONNECTION METHOD AND LOCATION PRESENTED ON PV5 OF 3 LINE DIAGRAM. PV5 LINE DIAGRAM TO REFLECT ACTUAL REPRESENTATION OF PROPOSED SCOPE OF WORK. JUNCTION BOX OR COMBINER BOX MAIN SERVICE PANEL AC DISCONNECT EXISTING SUB PANEL (IF WHERE POINT OF INTERCONNECTION IS MADE) PV COMBINER SUBPANEL - IF USED TO COMBINE PV OUTPUT CIRCUITS AC DC INVERTER (S) INTEGRATED DC DISCONNECT 2 3 47 3 9 5 (ONLY IF PV INTERCONNECTION CONSISTS OF LOAD SIDE BREAKER) 6 10 1 1 1 1 4 5 (ONLY IF PV INTERCONNECTION CONSISTS OF LOAD SIDE BREAKER) 4 6 3 LABELING DIAGRAM: 12 11 8OR LABEL 6 AT DIRECT-CURRENT EXPOSED RACEWAYS, CABLE TRAYS, COVERS AND ENCLOSURES OF JUNCTION BOXES, AND OTHER WIRING METHODS; SPACED AT MAXIMUM 10FT SECTION OR WHERE SEPARATED BY ENCLOSURES, WALLS, PARTITIONS, CEILINGS, OR FLOORS. [NEC 690.31(G)(3&4)] LABEL 10 (ONLY IF 3 OR MORE SUPPLY SOURCES TO A BUSBAR) SIGN LOCATED AT LOAD CENTER IF IT CONTAINS 3 OR MORE POWER SOURCES. [NEC 705.12(D)(2)(3)(C)] LABEL 9 SIGN LOCATED AT RAPID SHUT DOWN DISCONNECT SWITCH [NEC 690.56(C)(3)]. LABEL 7 FOR PV SYSTEMS THAT SHUT DOWN THE ARRAY AND CONDUCTORS LEAVING THE ARRAY: SIGN TO BE LOCATED ON OR NO MORE THAN 3 FT AWAY FROM SERVICE DISCONNECTING MEANS TO WHICH THE PV SYSTEMS ARE CONNECTED AND SHALL INDICATE THE LOCATION OF ALL IDENTIFIED RAPID SHUTDOWN SWITCHES IF NOT AT THE SAME LOCATION. [NEC 690.56(C)(1)(A)] LABEL 8 FOR PV SYSTEMS THAT ONLY SHUT DOWN CONDUCTORS LEAVING THE ARRAY: SIGN TO BE LOCATED ON OR NO MORE THAN 3 FT AWAY FROM SERVICE DISCONNECTING MEANS TO WHICH THE PV SYSTEMS ARE CONNECTED AND SHALL INDICATE THE LOCATION OF ALL IDENTIFIED RAPID SHUTDOWN SWITCHES IF NOT AT THE SAME LOCATION. [NEC 690.56(C)(1)(B)] LABEL 11 PLACARD TO BE PLACED AT THE MAIN BILLING METER PER XCEL ENERGY. LABEL 12 PLACARD TO BE PLACED AT AC DISCONNECT PER XCEL ENERGY. LABEL 1 FOR PV DISCONNECTING MEANS WHERE ALL TERMINALS OF THE DISCONNECTING MEANS MAY BE ENERGIZED IN THE OPEN POSITION. [NEC 690.13(B), NEC 705.22] LABEL 2 AT EACH DC DISCONNECTING MEANS, INCLUDING THE DC DISCONNECT AT THE INVERTER. [NEC 690.53, NEC 690.13(B)] LABEL 13 SIGN LOCATED AT MAIN SERVICE DISCONNECTING MEANS IF ALL ELECTRICAL POWER SOURCE DISCONNECTING MEANS ARE GROUPED WITHIN 10' AND LINE OF SITE OF MAIN SERVICE DISCONNECT [NEC 690.56(B) & NEC 705.10]. LABEL 14 SIGN LOCATED AT AC COMBINER BOX FOR ALL MICRO-INVERTER / AC MODULE INSTALLS (IF APPLICABLE). 13 14 LABELING NOTES: 1.LABELS CALLED OUT ACCORDING TO ALL COMMON CONFIGURATIONS. ELECTRICIAN TO DETERMINE EXACT REQUIREMENTS IN THE FIELD PER CURRENT NEC AND LOCAL CODES AND MAKE APPROPRIATE ADJUSTMENTS. 2.LABELING REQUIREMENTS BASED ON THE 2014 NATIONAL ELECTRIC CODE, OSHA STANDARD 19010.145, ANSI Z535. 3.MATERIAL BASED ON THE REQUIREMENTS OF THE AUTHORITY HAVING JURISDICTION. 4.LABELS TO BE OF SUFFICIENT DURABILITY TO WITHSTAND THE ENVIRONMENT INVOLVED [NEC 110.21] 5.LABELS TO BE A MINIMUM LETTER HEIGHT OF 3/8", WHITE ON RED BACKGROUND; REFLECTIVE, AND PERMANENTLY AFFIXED [IFC 605.11.1.1] 3 4 1 52 240 0 0 MMSPACINV SITE INFORMATION: Kristin Turner 20295 Hampton Ave, Lakeville, MN 55044 MAX CONTINUOUS AC SYSTEM SIZE: 12.604 kW AC DC SYSTEM SIZE: 15.18 kW DC Lat, Long: 44.6551258 , -93.2299848999999 (46) Silfab SIL-330 NL PV MODULES (23) AP Systems YC600 INVERTERSCONTRACTOR INFORMATION:Everlight Solar ConstructionPO Box 930550Verona, WI 53593License# DCQ-111802116833.786.4387 ext. 701Xcel Energy MNPOWER TO THIS BUILDING IS ALSO SUPPLIED FROM ROOF MOUNTED SOLAR ARRAYS WITH SAFETY DISCONNECTS AS SHOWN: CAUTION DIRECTORY PERMANENT PLAQUE OR DIRECTORY PROVIDING THE LOCATION OF THE SERVICE DISCONNECTING MEANS AND THE PHOTOVOLTAIC SYSTEM. (ALL PLAQUES AND SIGNAGE WILL BE INSTALLED AS OUTLINED WITHIN: NEC 690.56(B)&(C), [NEC 705.10]) DATE: December 23, 2020 PV08 PAGE: SHEET NAME: PLACARD DRAWN BY: SoloCAD PV ARRAY MAIN DISTRIBUTION UTILITY DISCONNECT 20295 Hampton Ave, Lakeville MN 55044 FRONT OF HOMEAC DISCONNECT INVERTER & RAPID SHUTDOWN DC DISCONNECT SWITCH SITE INFORMATION: Kristin Turner 20295 Hampton Ave, Lakeville, MN 55044 MAX CONTINUOUS AC SYSTEM SIZE: 12.604 kW AC DC SYSTEM SIZE: 15.18 kW DC Lat, Long: 44.6551258 , -93.2299848999999 (46) Silfab SIL-330 NL PV MODULES (23) AP Systems YC600 INVERTERSCONTRACTOR INFORMATION:Everlight Solar ConstructionPO Box 930550Verona, WI 53593License# DCQ-111802116833.786.4387 ext. 701Xcel Energy MNDATE: December 23, 2020 PV09 PAGE: SHEET NAME: SITE PHOTOS DRAWN BY: SoloCAD SITE PHOTOS: SITE INFORMATION: Kristin Turner 20295 Hampton Ave, Lakeville, MN 55044 MAX CONTINUOUS AC SYSTEM SIZE: 12.604 kW AC DC SYSTEM SIZE: 15.18 kW DC Lat, Long: 44.6551258 , -93.2299848999999 (46) Silfab SIL-330 NL PV MODULES (23) AP Systems YC600 INVERTERSCONTRACTOR INFORMATION:Everlight Solar ConstructionPO Box 930550Verona, WI 53593License# DCQ-111802116833.786.4387 ext. 701Xcel Energy MNDATE: December 23, 2020 PV09 PAGE: SHEET NAME: SITE PHOTOS DRAWN BY: SoloCAD SITE PHOTOS: SITE INFORMATION: Kristin Turner 20295 Hampton Ave, Lakeville, MN 55044 MAX CONTINUOUS AC SYSTEM SIZE: 12.604 kW AC DC SYSTEM SIZE: 15.18 kW DC Lat, Long: 44.6551258 , -93.2299848999999 (46) Silfab SIL-330 NL PV MODULES (23) AP Systems YC600 INVERTERSCONTRACTOR INFORMATION:Everlight Solar ConstructionPO Box 930550Verona, WI 53593License# DCQ-111802116833.786.4387 ext. 701Xcel Energy MNDATE: December 23, 2020 PV09 PAGE: SHEET NAME: SITE PHOTOS DRAWN BY: SoloCAD SITE PHOTOS: SITE INFORMATION: Kristin Turner 20295 Hampton Ave, Lakeville, MN 55044 MAX CONTINUOUS AC SYSTEM SIZE: 12.604 kW AC DC SYSTEM SIZE: 15.18 kW DC Lat, Long: 44.6551258 , -93.2299848999999 (46) Silfab SIL-330 NL PV MODULES (23) AP Systems YC600 INVERTERSCONTRACTOR INFORMATION:Everlight Solar ConstructionPO Box 930550Verona, WI 53593License# DCQ-111802116833.786.4387 ext. 701Xcel Energy MNDATE: December 23, 2020 PV09.1 PAGE: SHEET NAME: SITE PHOTOS DRAWN BY: SoloCAD SITE PHOTOS: SITE INFORMATION: Kristin Turner 20295 Hampton Ave, Lakeville, MN 55044 MAX CONTINUOUS AC SYSTEM SIZE: 12.604 kW AC DC SYSTEM SIZE: 15.18 kW DC Lat, Long: 44.6551258 , -93.2299848999999 (46) Silfab SIL-330 NL PV MODULES (23) AP Systems YC600 INVERTERSCONTRACTOR INFORMATION:Everlight Solar ConstructionPO Box 930550Verona, WI 53593License# DCQ-111802116833.786.4387 ext. 701Xcel Energy MNDATE: December 23, 2020 PV09.2 PAGE: SHEET NAME: SITE PHOTOS DRAWN BY: SoloCAD SITE PHOTOS: SITE INFORMATION: Kristin Turner 20295 Hampton Ave, Lakeville, MN 55044 MAX CONTINUOUS AC SYSTEM SIZE: 12.604 kW AC DC SYSTEM SIZE: 15.18 kW DC Lat, Long: 44.6551258 , -93.2299848999999 (46) Silfab SIL-330 NL PV MODULES (23) AP Systems YC600 INVERTERSCONTRACTOR INFORMATION:Everlight Solar ConstructionPO Box 930550Verona, WI 53593License# DCQ-111802116833.786.4387 ext. 701Xcel Energy MNDATE: December 23, 2020 PV09.3 PAGE: SHEET NAME: SITE PHOTOS DRAWN BY: SoloCAD CASE# 04249303 Tech Brief Solar Is Not Always Sunny Over their lifetime, solar panels experience countless extreme weather events. Not just the worst storms in years, but the worst storms in 40 years. High winds capable of ripping panels from a roof, and snowfalls weighing enough to buckle a panel frame. XR Rails are the structural backbone preventing these results. They resist uplift, protect against buckling and safely and efficiently transfer loads into the building structure. Their superior spanning capability requires fewer roof attachments, reducing the number of roof penetrations and the amount of installation time. XR Rail Family Force-Stabilizing Curve Sloped roofs generate both vertical and lateral forces on mounting rails which can cause them to bend and twist. The curved shape of XR Rails is specially designed to increase strength in both directions while resisting the twisting. This unique feature ensures greater security during extreme weather and a longer system lifetime. Compatible with Flat & Pitched Roofs Roof Mount utilizes XR Rails, along with optional all-in-one attachments, to secure systems flush against residential roofs. Corrosion-Resistant Materials XR Rails are compatible with FlashFoot and other pitched roof attachments. IronRidge offers a range of tilt leg options for flat roof mounting applications. All XR Rails are made of 6000-series aluminum alloy, then protected with an anodized finish. Anodizing prevents surface and structural corrosion, while also providing a more attractive appearance. XR Rail Family The XR Rail Family offers the strength of a curved rail in three targeted sizes. Each size supports specific design loads, while minimizing material costs. Depending on your location, there is an XR Rail to match. © 2020 IronRidge, Inc. All rights reserved. Visit www.ironridge.com or call 1-800-227-9523 for more information. Version 1.20 Tech Brief Rail Selection The table below was prepared in compliance with applicable engineering codes and standards.* Values are based on the following criteria: ASCE 7-16, Gable Roof Flush Mount, Roof Zones 1 & 2e, Exposure B, Roof Slope of 8 to 20 degrees and Mean Building Height of 30 ft. Visit IronRidge.com for detailed certification letters. Load Rail Span Snow (PSF)Wind (MPH)4’5’ 4”6’8’10’12’ None 90 120 140 XR10 XR100 XR1000 160 20 90 120 140 160 30 90 160 40 90 160 80 160 120 160 XR100 XR100 is the ultimate residential mounting rail. It supports a range of wind and snow conditions, while also maximizing spans up to 10 feet. • 10’ spanning capability• Heavy load capability• Clear & black anodized finish• Internal splices available XR10 XR10 is a sleek, low-profile mounting rail, designed for regions with light or no snow. It achieves spans up to 6 feet, while remaining light and economical. • 6’ spanning capability• Moderate load capability• Clear & black anodized finish• Internal splices available XR1000 XR1000 is a heavyweight among solar mounting rails. It’s built to handle extreme climates and spans up to 12 feet for commercial applications. • 12’ spanning capability• Extreme load capability• Clear anodized finish• Internal splices available *Table is meant to be a simplified span chart for conveying general rail capabilities. Use approved certification letters for actual design guidance. THESE SHEETS, DESIGNS, AND SPECS ARE PROPERTY OF SUN INCORPORATED. NO PART SHALL BE DUPLICATED OR USED FOR NONE OTHER THAN ITS SPECIFIC PROJECT WITHOUT WRITTEN CONSENT FROM SUN INCORPORATED.MOUNT SHEETSheet: 5File: \\SUN-SERVER\Sun Incorporated Jobs Master\Equipment\MOUNTS\QUICK MOUNT\QMPV-datasheet-QMHSS-LS-QuickHookSM-web.pdfMissing or invalid referenceSheet: 2File: \\SUN-SERVER\Sun Incorporated Jobs Master\Equipment\MOUNTS\QUICK MOUNT\QMPV-datasheet-QMHSS-LS-QuickHookSM-web.pdfMissing or invalid reference