Loading...
HomeMy WebLinkAboutLA185474 -Approved Carlin IronRidge Racking Report UpdatedSystem Weight Total system weight 2,318.1 lbs Weight/attachment 29.7 lbs Racking weight 333.7 lbs Distributed weight 2.6 psf Load Assumptions Wind exposure B Wind speed 110 mph Ground snow load 50 psf Attachment spacing portrait 4.0' Site Elevation 1038.0 ft SDS 0.051 Span Details XR100 - Portrait Zone Module Position Max span Max cantilever Zone 1/2e/2r Normal 5' 11"2' 4" Zone 2n/3r Normal 5' 11"2' 4" Zone 3e Normal 5' 11"2' 4" Reaction Forces XR100 - Portrait Zone Module Position Down (lbs) Uplift (lbs) Lateral (lbs) Zone 1/2e/2r Normal 291 155 144 Zone 2n/3r Normal 291 179 144 Zone 3e Normal 291 228 144 Project Details Name Jason Carlin Date 10/27/2020 Location 17598 Heidelberg Way, Lakeville, MN 55044 Total modules 40 Module Jinko: JKM400M-72HL-V (40mm)Total watts 16,000 Dimensions 79.06" x 39.45" x 1.57" (2008.0mm x 1002.0mm x 40.0mm)Attachments 78 ASCE 7-16 Roof Information Roof material Comp Shingle Building height 30 ft Roof attachment Flashfoot2 Roof slope 30 ° Attachment hardware Square Risk category II Roof shape Gable Last updated by Iron Ridge on 10/27/20 06:42 AM Page 1 of 7 Jason Carlin (#693361) pitched roof 28357 INDUSTRIAL BLVD., HAYWARD, CA 94545 Roof Section 1 Definition Roof Section Weights Roof Section (all segments) 20 modules Total weight: 1,148.1 lbs Provided rail: 136' [8 x 17'] Portrait orientation Weight/attachment: 28.7 lbs Attachments: 40 Graphical entry Total Area: 442.4 sq ft Splices: 0 Distributed weight: 2.6 psf Clamps: 48 Diagram 39' 10"13' 2"Segments Columns Length Cantilever Rail Attachments Splices Clamps 5 16' 9"4"34' [2 x 17']10 0 12 Row segment totals (x 4) →136' [8 x 17']40 0 48 Roof Section 2 Definition Roof Section Weights Roof Section (all segments) 12 modules Total weight: 686.0 lbs Provided rail: 84' [6 x 14'] Portrait orientation Weight/attachment: 34.3 lbs Attachments: 20 Graphical entry Total Area: 263.3 sq ft Splices: 4 Distributed weight: 2.6 psf Clamps: 26 Diagram 39' 10"6' 7"Segments Columns Length Cantilever Rail Attachments Splices Clamps 12 40'2'84' [6 x 14']20 4 26 Last updated by Iron Ridge on 10/27/20 06:42 AM Page 2 of 7 Jason Carlin (#693361) pitched roof 28357 INDUSTRIAL BLVD., HAYWARD, CA 94545 Roof Section 3 Definition Roof Section Weights Roof Section (all segments) 4 modules Total weight: 253.5 lbs Provided rail: 56' [4 x 14'] Portrait orientation Weight/attachment: 25.4 lbs Attachments: 10 Graphical entry Total Area: 89.2 sq ft Splices: 0 Distributed weight: 2.8 psf Clamps: 12 Diagram 9' 11"13' 2"Segments Columns Length Cantilever Rail Attachments Splices Clamps 1 3' 5"0"28' [2 x 14']4 0 4 3 10' 1"1' 1"28' [2 x 14']6 0 8 Roof Section 4 Definition Roof Section Weights Roof Section (all segments) 4 modules Total weight: 230.5 lbs Provided rail: 28' [2 x 14'] Portrait orientation Weight/attachment: 28.8 lbs Attachments: 8 Graphical entry Total Area: 88.4 sq ft Splices: 0 Distributed weight: 2.6 psf Clamps: 10 Diagram 13' 3"6' 7"Segments Columns Length Cantilever Rail Attachments Splices Clamps 4 13' 5"8"28' [2 x 14']8 0 10 Last updated by Iron Ridge on 10/27/20 06:42 AM Page 3 of 7 Jason Carlin (#693361) pitched roof 28357 INDUSTRIAL BLVD., HAYWARD, CA 94545 Side View (portrait) 30° BUILDING STRUCTURE ROOF MEMBRANE FLASHFOOT2 RAIL PV MODULE Front View (portrait) ATTACHMENT SPAN 4.0’ BUILDING STRUCTURE ROOF MEMBRANE FLASHFOOT2 RAIL PV MODULE Last updated by Iron Ridge on 10/27/20 06:42 AM Page 4 of 7 Jason Carlin (#693361) pitched roof 28357 INDUSTRIAL BLVD., HAYWARD, CA 94545 Splice Details XR100 SIDE-FACING SLOT INTERNAL SPLICE TOP-FACING SLOT Splice Connection INTERNAL SPLICE RAIL SELF-DRIVING SCREW Clamp Detail Mid Clamp, Plan UNIVERSAL FASTENING OBJECT PV MODULE FRAME Mid Clamp, Front RAIL PV MODULEFRAME UNIVERSALFASTENINGOBJECT End Clamp, Plan STOPPERSLEEVE UNIVERSALFASTENINGOBJECT PV MODULEFRAME RAIL 1” End Clamp, Front PV MODULEFRAME RAIL UNIVERSALFASTENINGOBJECT STOPPERSLEEVE1” FlashFoot2 Detail Plan View 9” 12” 2 “316 Side View 1 “1116 Perspective View Front View 1 “58 3 “516 “516 Last updated by Iron Ridge on 10/27/20 06:42 AM Page 5 of 7 Jason Carlin (#693361) pitched roof 28357 INDUSTRIAL BLVD., HAYWARD, CA 94545 Grounding Diagram * Grounding Lugs and Wire are not required in systems using Enphase microinverters. UFO Clamp Fault Current Ground Path Min 10 AWG Copper Wire * Grounding Lug * Bonded Splice (Rail Connection) Last updated by Iron Ridge on 10/27/20 06:42 AM Page 6 of 7 Jason Carlin (#693361) pitched roof 28357 INDUSTRIAL BLVD., HAYWARD, CA 94545 Bill of Materials Part Spares Total Qty Rails & Splices XR-100-204A XR100, Rail 204" (17 Feet) Clear 0 8 XR-100-168A XR100, Rail 168" (14 Feet) Clear 0 12 XR-100-SPLC-M1 XR100 Bonded Splice (Incl. Self-tapping Screws)0 4 Clamps & Grounding UFO-CL-01-A1 Universal Module Clamp, Clear 0 96 UFO-STP-40MM-M1 Stopper Sleeve, 40MM, Mill 0 32 XR-LUG-03-A1 Grounding Lug, Low Profile 0 8 Attachments FF2-01-M2 FlashFoot2, Mill 0 78 BHW-SQ-02-A1 Square-Bolt Bonding Hardware 0 78 Last updated by Iron Ridge on 10/27/20 06:42 AM Page 7 of 7 Jason Carlin (#693361) pitched roof 28357 INDUSTRIAL BLVD., HAYWARD, CA 94545