Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
LA188706 - Approved Permit Packet - Steege
C O N T R A C T O RMOXIE SOLAR(855) 669-4387INFO@MOXIESOLAR.COM323 W CHERRY STNORTH LIBERTY, IA 52317O W N E RTIMOTHY (TIM)STEEGE(651) 245-0113TIMSTEEGE@GMAIL.COM19344 HUXLEY AVELAKEVILLE, MN 55044A H JU T I L T YR E V I S I O N SPROJECT NAME: STEEGE, TIMOTHY (TIM)MN-3181-102/17/21 PLAN SETCLDAKOTA ELECTRICASSOCIATION(651) 463-6212LAKEVILLE, MN(952) 985-440020195 HOLYOKE AVELAKEVILLE, MN 55044DESIGN SUMMARY01DESIGN SUMMARY·SIZE: 7.680 kW PV Solar System (24 modules)·STYLE: Residential, asphalt shingle roof, flush mount, grid tied, net-metered·LOCATION: Northeast facing roof of home·ORIENTATION: Portrait, 27° pitch, 68° azimuth·MODULE: Hanwha Q.PEAK DUO L-G5 320W, 66.4"x 39.4"x 1.26" thick, 41.3 lbs·RACKING: Iron Ridge XR-100 with asphalt shingle roof flashings·INVERTER: Enphase IQ7+ MicroInverters·VOLTAGE: 120/240V, 1Φ·MONITORING: Enphase Enlighten Online Monitoring·ADDITIONAL WORK: NoneTHIS DISTRIBUTED GENERATION FACILITY WAS INSTALLEDIN ACCORDANCE WITH THE CURRENT STATE ADOPTEDNATIONAL ELECTRICAL CODE101SITE MAPNO SCALENPV Solar ArrayRoof of buildingEnphase MicroinverterArrayPV Solar Dedicated Load CenterBuilding ExteriorMain Service PanelBuilding InteriorUtility MeterBuilding ExteriorML CPAC Solar DisconnectBuilding ExteriorDMDP 55'14'16'-7"49'-10"11'3'C O N T R A C T O RMOXIE SOLAR(855) 669-4387INFO@MOXIESOLAR.COM323 W CHERRY STNORTH LIBERTY, IA 52317O W N E RTIMOTHY (TIM)STEEGE(651) 245-0113TIMSTEEGE@GMAIL.COM19344 HUXLEY AVELAKEVILLE, MN 55044A H JU T I L T YR E V I S I O N SPROJECT NAME: STEEGE, TIMOTHY (TIM)MN-3181-102/17/21 PLAN SETCLDAKOTA ELECTRICASSOCIATION(651) 463-6212LAKEVILLE, MN(952) 985-440020195 HOLYOKE AVELAKEVILLE, MN 55044BUILD SUMMARY02BUILD SUMMARY·MODULE: QTY (24) Q.PEAK DUO L-G5 320W, 66.4"x 39.4"x 1.26" thick, 41.3 lbs·STRUCTURE: Wood prefabricated 2"x 4" trusses @ 24" OC·RACKING: Iron Ridge XR-100 with asphalt shingle roof flashing. Run rails across the trusses. Penetrate every 4ft or less into trusses. Installer must verify allpenetrations are secure and centered in wood members. Any damaged wood members must be repaired immediately by scab, sister, or full replacement. Max RailOverhang = 19” from last attachment point. Module Overhang = 18”·ACCESS: 1-story residence·INVERTERS: Mount microinverters at module locations·MONITORING: Enphase Enlighten online monitoring·ADDITIONAL WORK: None102ARRAY DESIGNNO SCALE C O N T R A C T O RMOXIE SOLAR(855) 669-4387INFO@MOXIESOLAR.COM323 W CHERRY STNORTH LIBERTY, IA 52317O W N E RTIMOTHY (TIM)STEEGE(651) 245-0113TIMSTEEGE@GMAIL.COM19344 HUXLEY AVELAKEVILLE, MN 55044A H JU T I L T YR E V I S I O N SPROJECT NAME: STEEGE, TIMOTHY (TIM)MN-3181-102/17/21 PLAN SETCLDAKOTA ELECTRICASSOCIATION(651) 463-6212LAKEVILLE, MN(952) 985-440020195 HOLYOKE AVELAKEVILLE, MN 55044ELECTRICAL03103ONE-LINE ELECTRICAL DIAGRAM - 7.680 KW (DC)NO SCALEPV ACDISCONNECTBACK-FED BREAKER &EXISTING MAIN PANELUTILITY METER679W4W6200A, 2P40A, 2PEQUIPMENT SCHEDULETAGITEMMAKEMODELVOLTAGEQTYLOCATION1MODULEHANWHAQ.PEAK DUO L-G5320WDC24ROOF TOP2MICROINVERTERENPHASEIQ7PLUS-72-2-US290W (AC)120/240V, 1Φ24ROOF TOP3JUNCTION BOXVYNCHIERRJ1120/240V, 1Φ2ROOF TOP4BREAKERSEATON20A, 2-POLE BR220120/240V, 1Φ2LOAD CENTER5LOAD CENTERENPHASEIQ COMBINERX-IQ-AM1-240-3ES120/240V, 1Φ1BLD EXTERIOR6DISCONNECTEATON60A ENCLOSURENON FUSED120/240V, 1Φ1BLD EXTERIOR7BACK-FEDBREAKEREATON40A, 2-POLEBR240120/240V, 1Φ1MAIN PANEL8MAIN PANELEATON200A ENCLOSURE200A MAIN120/240V, 1Φ1BLD INTERIOR9UTILITY METERITRONCL200120/240V, 1Φ1BLD EXTERIORWIRE SCHEDULETAGRUNCONDUCTORTYPEGAUGECONDUITRUNLENGTHW1PV HOMERUNSQ-CABLE#12-60 FTW2JUNCTION BOX TO LOAD CENTERTHWN-2, Cu#1034"30 FTW3LOAD CENTER TO DISCONNECTTHWN-2, Cu#81"5 FTW4DISCONNECT TO BACK-FEDTHWN-2, Cu#81"5 FTW5GROUND ELECTRODEBARE, Cu#6--W6EQUIPMENT GROUNDTHWN-2, Cu#6 (MIN)-100 FTS1S2MODULE & MICROINVERTERJUNCTIONBOXRAPID SHUTDOWN ENABLED3W5BREAKERS & ENPHASELOAD CENTER45W3W1S1STRING OF 13JB20A, 2PW1S2STRING OF 9JB20A, 2PW2W2812 C O N T R A C T O RMOXIE SOLAR(855) 669-4387INFO@MOXIESOLAR.COM323 W CHERRY STNORTH LIBERTY, IA 52317O W N E RTIMOTHY (TIM)STEEGE(651) 245-0113TIMSTEEGE@GMAIL.COM19344 HUXLEY AVELAKEVILLE, MN 55044A H JU T I L T YR E V I S I O N SPROJECT NAME: STEEGE, TIMOTHY (TIM)MN-3181-102/17/21 PLAN SETCLDAKOTA ELECTRICASSOCIATION(651) 463-6212LAKEVILLE, MN(952) 985-440020195 HOLYOKE AVELAKEVILLE, MN 55044DETAILS & CALCULATIONS04204304PHOTOVOLTAIC MARKING AND LABELINGNO SCALECODE REVIEW & CALCULATIONSSYSTEM AC DISCONNECT AT SERVICEPHOTOVOLTAIC SYSTEM AC DISCONNECTMAXIMIM OPERATING AC CURRENT:NOMINAL OPERATING AC VOLTAGE:29.04 AMPS120/240 VAC104MODULE AND MICROINVERTER CONNECTION DETAILNO SCALESOLAR PHOTOVOLTAIC (PV) SYSTEM WITH ENPHASEInverter Type: Enphase IQ7+ MicroInverterMinimum String Length: N/AMaximum String Length: 13Nominal String AC Voltage: 240V (AC)Nominal Output Current (Per MicroInverter): 1.21ANEC 690.8 CIRCUIT SIZING AND CURRENT690.8(A)(1): Photovoltaic Source Circuit CurrentsModule to MicroInverter Imax = 1.21A x 24 x 125% = 36.30A690.8(A)(3): Inverter Output Circuit Current.MicroInverter Rated Continuous Output Power = 290WMicroInverter rated Continuous Output Current = 1.21ASystem Imax = 36.30ANEC 690.9 OVERCURRENT PROTECTION690.9(B): Overcurrent Device RatingsDisconnect Fuse: 1.21A x 24 x 125% = 36.30A -> 40A OCPDNEC 690.12 RAPID SHUTDOWN OF PV SYSTEMS ON BUILDINGSPLAN: Rapid Shutdown enabled disconnect shall be located next to the service and be labeledin accordance with 690.56(B) and (C).Hanwha Q.PEAK DUO L-G5 320WNEC 690.7 MAXIMUM VOLTAGE690.7(A): Maximum Photovoltaic System VoltageQ.PEAK DUO L-G5 320W Module Voc = 40.56VModule Vmax = ((-40°C)-25°C)(-0.0027V/°C)(40.56V)+(40.56V) = 47.68V (DC)Module Vmax Output = 47.68V (DC) < IQ7+ MAX Input = 60V (DC)IRONRIDGE ASPHALT SHINGLE FLASHING DETAILNO SCALE Q.ANTUM TECHNOLOGY: LOW LEVELISED COST OF ELECTRICITY Higher yield per surface area, lower BOS costs, higher power classes, and an efficiency rate of up to 19.6 %. INNOVATIVE ALL-WEATHER TECHNOLOGY Optimal yields, whatever the weather with excellent low-light and temperature behaviour. ENDURING HIGH PERFORMANCE Long-term yield security with Anti LID Technology, Anti PID Technology1, Hot-Spot Protect and Traceable Quality Tra.Q™. EXTREME WEATHER RATING High-tech aluminium alloy frame, certified for high snow (5400 Pa) and wind loads (4000 Pa). A RELIABLE INVESTMENT Inclusive 12-year product warranty and 25-year linear performance warranty2. STATE OF THE ART MODULE TECHNOLOGY Q.ANTUM DUO combines cutting edge cell separation and innovative wiring with Q.ANTUM Technology. 1 APT test conditions according to IEC/TS 62804-1:2015, method B (−1500 V, 168 h) 2 See data sheet on rear for further information. YIELD SECURITY ANTI PID TECHNOLOGY(APT) HOT-SPOT PROTECT(HSP) TRACEABLE QUALITY(TRA.QTM) ANTI LID TECHNOLOGY(ALT) www.VDEinfo.comID. 40032587 Quality Tested high reliabilitylow degradationoptimized durabilitycontinous line monitoring 11/2016 EN THE IDEAL SOLUTION FOR: Rooftop arrays on residential buildings Q.PEAK DUO BLK-G5 310-325 ENDURING HIGH PERFORMANCE DETAIL A 16 mm 8.5 mm24.5 mm 980 mm 1685 mm 4 × Mounting slots (DETAIL A) Frame 1000 mm 951 mm 32 mm 8 × Drainage holes 352.5 mm EN 4 × Grounding points ø 4.5 mm 1100 mm 1100 mm Label EN RELATIVE EFFICIENCYCOMPARED TO NOMINAL POWER [%]100 95 90 85 80 75 155 2520010YEARS 98 Q CELLS Industry standard for tiered warranties* Industry standard for linear warranties* *Standard terms of guarantee for the 10 PV companieswith the highest production capacity in 2014 (as at: September 2014) 200 400 600 800 1000 110 100 90 80RELATIVE EFFICIENCY [%]IRRADIANCE [W/m²] α [% / K]+0.04 β [% / K]−0.27 γ [% / K]−0.36 NMOT [°C]43 ± 3 [V]1000 Class II [A]20 C / TYPE 2 [Pa]3600 / 2667 −40 °C - +85 °C [Pa]5400 / 4000 24t 40' HC 310 315 320 325 [W]310 315 320 325 [A]9.83 9.89 9.94 10.00 [V]40.02 40.29 40.56 40.83 [A]9.36 9.41 9.47 9.52 [V]33.12 33.46 33.80 34.14 [%]≥ 18.4 ≥ 18.7 ≥ 19.0 ≥ 19.3 [W]232.0 235.8 239.5 243.3 [A]7.92 7.97 8.01 8.05 [V]37.73 37.99 38.24 38.50 [A]7.37 7.41 7.45 7.49 [V]31.50 31.82 32.14 32.46 1730 mm 1040 mm 1208 mm 634.4 kg 1760 mm 1150 mm 1190 mm 642 kg Hanwha Q CELLS GmbH Sonnenallee 17-21, 06766 Bitterfeld-Wolfen, Germany | TEL +49 (0)3494 66 99-23444 | FAX +49 (0)3494 66 99-23000 | EMAIL sales@q-cells.com | WEB www.q-cells.com Note: Installation instructions must be followed. See the installation and operating manual or contact our technical service department for further information on approved installation and use of this product. Q CELLS supplies solar modules in two different stacking methods, depending on the location of manufacture (modules are packed horizontally or vertically). You can find more detailed information in the document “Packaging and Transport Information”, available from Q CELLS. Q CELLS PERFORMANCE WARRANTY PERFORMANCE AT LOW IRRADIANCE At least 98 % of nominal power dur- ing first year. Thereafter max. 0.54 % degradation per year. At least 93.1 % of nominal power up to 10 years. At least 85 % of nominal power up to 25 years. All data within measurement toler- ances. Full warranties in accordance with the warranty terms of the Q CELLS sales organisation of your respective country.Typical module performance under low irradiance conditions in comparison to STC conditions (25 °C, 1000 W/m2).Specifications subject to technical changes © Q CELLS Q.PEAK DUO BLK-G5_310-325_2020-04_Rev02_ENPROPERTIES FOR SYSTEM DESIGN Maximum System Voltage VSYS PV module classification Maximum Reverse Current IR Fire Rating based on ANSI / UL 61730 Max. Design Load, Push / Pull Permitted Module Temperature on Continuous DutyMax. Test Load, Push / Pull ELECTRICAL CHARACTERISTICS POWER CLASS MINIMUM PERFORMANCE AT STANDARD TEST CONDITIONS, STC1 (POWER TOLERANCE +5 W / −0 W)MinimumPower at MPP1 PMPP Short Circuit Current1 ISC Open Circuit Voltage1 VOC Current at MPP IMPP Voltage at MPP VMPP Efficiency1 η MINIMUM PERFORMANCE AT NORMAL OPERATING CONDITIONS, NMOT2 MinimumPower at MPP PMPP Short Circuit Current ISC Open Circuit Voltage VOC Current at MPP IMPP Voltage at MPP VMPP 1Measurement tolerances PMPP ± 3 %; ISC; VOC ± 5 % at STC: 1000 W/m2, 25 ± 2 °C, AM 1.5 according to IEC 60904-3 • 2800 W/m², NMOT, spectrum AM 1.5 MECHANICAL SPECIFICATION Format 1685 mm × 1000 mm × 32 mm (including frame) Weight 18.7 kg Front Cover 3.2 mm thermally pre-stressed glass with anti-reflection technology Back Cover Composite film Frame Black anodised aluminium Cell 6 × 20 monocrystalline Q.ANTUM solar half cells Junction box 53-101 mm × 32-60 mm × 15-18 mm Protection class IP67, with bypass diodes Cable 4 mm² Solar cable; (+) ≥ 1100 mm, (−) ≥ 1100 mm Connector Stäubli MC4, Hanwha Q CELLS HQC4; IP68 TEMPERATURE COEFFICIENTS Temperature Coefficient of ISC Temperature Coefficient of VOC Temperature Coefficient of PMPP Nominal Module Operating Temperature QUALIFICATIONS AND CERTIFICATES PACKAGING INFORMATION VDE Quality Tested, IEC 61215:2016; IEC 61730:2016. This data sheet complies with DIN EN 50380. Horizontal packaging 30 pallets 26 pallets 32 modules Vertical packaging 30 pallets 26 pallets 32 modules The high-powered smart grid-ready Enphase IQ 7 Micro™ and Enphase IQ 7+ Micro™ dramatically simplify the installation process while achieving the highest system efficiency. Part of the Enphase IQ System, the IQ 7 and IQ 7+ Microinverters integrate with the Enphase IQ Envoy™, Enphase IQ Battery™, and the Enphase Enlighten™ monitoring and analysis software. IQ Series Microinverters extend the reliability standards set forth by previous generations and undergo over a million hours of power-on testing, enabling Enphase to provide an industry-leading warranty of up to 25 years. Enphase IQ 7 and IQ 7+ Microinverters To learn more about Enphase offerings, visit enphase.com Data SheetEnphase MicroinvertersRegion: AMERICAS Easy to Install • Lightweight and simple • Faster installation with improved, lighter two-wire cabling • Built-in rapid shutdown compliant (NEC 2014 & 2017) Productive and Reliable • Optimized for high powered 60-cell/120 half-cell and 72- cell/144 half-cell* modules • More than a million hours of testing • Class II double-insulated enclosure • UL listed Smart Grid Ready • Complies with advanced grid support, voltage and frequency ride-through requirements • Remotely updates to respond to changing grid requirements • Configurable for varying grid profiles • Meets CA Rule 21 (UL 1741-SA) * The IQ 7+ Micro is required to support 72-cell/144 half-cell modules. 1. No enforced DC/AC ratio. See the compatibility calculator at https://enphase.com/en-us/support/module-compatibility. 2. Nominal voltage range can be extended beyond nominal if required by the utility.3. Limits may vary. Refer to local requirements to define the number of microinverters per branch in your area. To learn more about Enphase offerings, visit enphase.com © 2020 Enphase Energy. All rights reserved. Enphase, the Enphase logo, Enphase IQ 7, Enphase IQ 7+, Enphase IQ Battery, Enphase Enlighten, Enphase IQ Envoy, and other trademarks or service names are the trademarks of Enphase Energy, Inc. Data subject to change. 2020-08-12 INPUT DATA (DC) IQ7-60-2-US IQ7PLUS-72-2-US Commonly used module pairings¹235 W - 350 W +235 W - 440 W + Module compatibility 60-cell/120 half-cell PV modules only 60-cell/120 half-cell and 72-cell/144 half-cell PV modules Maximum input DC voltage 48 V 60 V Peak power tracking voltage 27 V - 37 V 27 V - 45 V Operating range 16 V - 48 V 16 V - 60 V Min/Max start voltage 22 V / 48 V 22 V / 60 V Max DC short circuit current (module Isc)15 A 15 A Overvoltage class DC port II II DC port backfeed current 0 A 0 A PV array configuration 1 x 1 ungrounded array; No additional DC side protection required; AC side protection requires max 20A per branch circuit OUTPUT DATA (AC) IQ 7 Microinverter IQ 7+ Microinverter Peak output power 250 VA 295 VA Maximum continuous output power 240 VA 290 VA Nominal (L-L) voltage/range²240 V / 211-264 V 208 V / 183-229 V 240 V / 211-264 V 208 V / 183-229 V Maximum continuous output current 1.0 A (240 V)1.15 A (208 V)1.21 A (240 V)1.39 A (208 V) Nominal frequency 60 Hz 60 Hz Extended frequency range 47 - 68 Hz 47 - 68 Hz AC short circuit fault current over 3 cycles 5.8 Arms 5.8 Arms Maximum units per 20 A (L-L) branch circuit³16 (240 VAC)13 (208 VAC)13 (240 VAC)11 (208 VAC) Overvoltage class AC port III III AC port backfeed current 18 mA 18 mA Power factor setting 1.0 1.0 Power factor (adjustable)0.85 leading ... 0.85 lagging 0.85 leading ... 0.85 lagging EFFICIENCY @240 V @208 V @240 V @208 V Peak efficiency 97.6 %97.6 %97.5 %97.3 % CEC weighted efficiency 97.0 %97.0 %97.0 %97.0 % MECHANICAL DATA Ambient temperature range -40ºC to +65ºC Relative humidity range 4% to 100% (condensing) Connector type MC4 (or Amphenol H4 UTX with additional Q-DCC-5 adapter) Dimensions (HxWxD)212 mm x 175 mm x 30.2 mm (without bracket) Weight 1.08 kg (2.38 lbs) Cooling Natural convection - No fans Approved for wet locations Yes Pollution degree PD3 Enclosure Class II double-insulated, corrosion resistant polymeric enclosure Environmental category / UV exposure rating NEMA Type 6 / outdoor FEATURES Communication Power Line Communication (PLC) Monitoring Enlighten Manager and MyEnlighten monitoring options.Both options require installation of an Enphase IQ Envoy. Disconnecting means The AC and DC connectors have been evaluated and approved by UL for use as the load-break disconnect required by NEC 690. Compliance CA Rule 21 (UL 1741-SA)UL 62109-1, UL1741/IEEE1547, FCC Part 15 Class B, ICES-0003 Class B, CAN/CSA-C22.2 NO. 107.1-01 This product is UL Listed as PV Rapid Shut Down Equipment and conforms with NEC 2014, NEC 2017, and NEC 2020 section 690.12 and C22.1-2015 Rule 64-218 Rapid Shutdown of PV Systems, for AC and DC conductors, when installed according manufacturer’s instructions. Enphase IQ 7 and IQ 7+ Microinverters Cut Sheet See Description / Length 2.44 .58 1.25 2.34 1.99 .66 .46 APPROVED MATERIALS: 6005-T6, 6005A-T61, 6105-T5, 6N01-T6 (34,000 PSI YIELD STRENGTH MINIMUM) XR100 Rail v1.1 RESIDENTIAL BUILDING PERMIT APPLICATION CITY OF LAKEVILLE BUILDING INSPECTIONS DEPARTMENT 20195 HOLYOKE AVENUE LAKEVILLE, MN 55044 952-985-4440 Office Use Only __________________ Permit Number ___________________ Received By ___________________ Date Received ___________________ Fee Total SITE ADDRESS: MAILING ADDRESS: CITY: STATE: ZIP: JOB DESCRIPTION:__________________________________ MASTER PLAN: (Number or Address)____________________ LIST OTHER STRUCTURES ON PROPERTY:_______________________________________________________________ ESTIMATED VALUATION: PROPOSED START DATE: END DATE: (New Residential Only): LEGAL DESCRIPTION: LOT: _____ BLOCK: _____ SUBDIVISION: APPLICANT IS: RESIDENT OWNER CONTRACTOR EMAIL NEW MODEL HOME: YES NO (IF YES – ADMINISTRATIVE PERMIT REQUIRED) PLEASE FILL OUT THE FOLLOWING COMPLETELY (All Contractor information must be as listed on State License) RESIDENT OWNER NAME:_______________________________________________________________________________ HOME PHONE #:_____________________________ CELL PHONE:___________________________ GENERAL CONTRACTOR Homeowner Contractor CONTRACTOR:_______________________________________________________________________ LICENSE #:BC______________ LEAD CERTIFICATE#_______________ (PRE 1978 STRUCTURE) OFFICE PHONE #:_____________________________ CELL PHONE:___________________________ ADDRESS:____________________________ CITY:________________ ST:______ ZIP:____________ PLUMBING WORK Homeowner Contractor CONTRACTOR:__________________________________________LICENSE #: PM______________ OFFICE PHONE #:_____________________________ CELL PHONE:___________________________ ADDRESS:____________________________ CITY:________________ ST:______ ZIP:____________ MECHANICAL WORK Homeowner Contractor CONTRACTOR:________________________________________ _______________________________ OFFICE PHONE #:_____________________________ CELL PHONE:___________________________ ADDRESS:____________________________ CITY:________________ ST:______ ZIP:____________ BOND #:_______________________________________ EXPIRATION DATE____________________ SEWER/WATER CONTRACTOR New Construction Only NAME:________________________________________________ ______________________________ HOME PHONE _____________________________ CELL PHONE:______________________________ BOND #:_______________________________________ EXPIRATION DATE____________________ INTEREST EARNINGS ON THE ESCROW ACCOUNTS, IF ANY, ARE RETAINED BY THE CITY TO OFFSET THE ADMINISTRATIVE COSTS ASSOCIATED WITH PROCESSING THE ESCROW APPLICATION AND REFUND. I HEREBY APPLY FOR A BUILDING PERMIT AND I ACKNOWLEDGE THAT THE INFORMATION ABOVE IS COMPLETE AND ACCURATE; THAT THE WORK WILL BE IN CONFORMANCE WITH THE ORDINANCES AND CODES OF THE CITY AND WITH THE STATE BUILDING CODE, THAT I UNDERSTAND THIS IS NOT A PERMIT AND WORK IS NOT TO START WITHOUT A PERMIT AND THAT THE WORK WILL BE IN ACCORDANCE WITH THE APPROVED PLAN. NAME OF APPLICANT (Please Print)DATE APPLICANT’S SIGNATURE: www.lakevillemn.gov 0.00 19344 Huxley Avenue, Lakeville, MN 55044 19344 Huxley Avenue, Lakeville MN 55044 installing 7.68 kW roof mount solar system 19344 Huxley Avenue Steege, Timothy (Tim) 651-245-0113 651-245-0113 RESIDENTIAL BUILDING PERMIT APPLICATION PAGE 2 OFFICE USE ONLY BUILDING PERMIT TYPE REQUIRED INSPECTIONS SINGLE FAMILY DWELLING BUILDING DUPLEX AS BUILT TOWNHOUSE UNITS BUILDING FINAL DETACHED TOWN HOUSE UNIT DECK FOOTING CONDO FIREPLACE ACESSORY BUILDING FOOTING REROOF FOUNDATION RESIDE FRAMING PORCH FRAMING GARAGES INSULATION RES ADDN/REPAIR/RMDL DECK PORCH GARAGES LATH LOWER LEVEL FINISH LOWER LEVEL FINAL ADDITION OTHER FOUNDATION ONLY PORCH FOOTING MISCELLANEOUS POURED WALL DEMO SEPTIC TANK REMOVAL MOVED SITE MECHANICAL CITY BUILDING VALUATION: $AIR TEST FINAL BUILDING PERMIT FEES ROUGH-IN $PERMIT FEE PLUMBING $PLAN CHECK FINAL $SURCHARGE ROUGH-IN $METRO SAC METER SIZE $CITY WATER HOOKUP UNIT PRESSURE REDUCING VALVE $CITY SEWER HOOKUP UNIT SEWER/WATER $LANDSCAPE ESCROW SEWER/WATER $TREE ESCROW FINAL $MISC ESCROW STREET DRAINTILE $PLUMBING BUILDING INFORMATION $MECHANICAL TYPE OF CONSTRUCTION $SEWER WATER ZONING $OTHER CODE EDITION $TOTAL FIRE SUPPRESSION SYSTEM OCCUPANCY GROUP APPROVED BY: BUILDING INSPECTOR: Date: PLUMBING/MECHANICAL INSPECTOR: Date: COMMENTS: 65% 0.00 ELECTRICAL PERMIT APPLICATION CITY OF LAKEVILLE BUILDING INSPECTIONS DEPARTMENT 20195 HOLYOKE AVENUE LAKEVILLE, MN 55044 952-985-4440 Office Use Only ___________________ Permit Number ___________________ Received By ___________________ Date Received ___________________ Fee Total DATE YOUR E-MAIL ADDRESS SITE ADDRESS TENANT SUITE NO. THE APPLIANT IS: RESIDENT OWNER CONTRACTOR RESIDENT OWNER NAME_________________________________________________________________________ ADDRESS______________________________________________________________________ CITY _____________________________ STATE_____________ ZIP _____________________ DAYTIME PHONE # WHERE YOU CAN BE REACHED ______________________________ CONTRACTOR Company name must be as appears on State License COMPANY NAME_______________________________________LICENSE #EA___________ ADDRESS_____________________________________________________________________ CITY _____________________________ STATE_____________ ZIP _____________________ OFFICE PHONE # ________________________ FAX #_______________________________ CONTACT NAME______________________________________ PHONE__________________ PERMIT TYPE SINGLE FAMILY TWO FAMILY TOWNHOUSE Meter Bank Single Meter MULTI-FAMILY COMMERCIAL / INDUSTRIAL MANUFACTURED HOME (Contractor Only) INSTITUTIONAL SWIMMING POOL UNDEFINED FIRE ALARM POWER SIGN OTHER (see description) Residential Addition/ Remodel Permits Available on-line TYPE OF WORK NEW MAINTENANCE/REPAIR ADDITION TENANT FINISH ALTER / REMODEL DEMOLITION Only Licensed Electrical Contractors can do work in a Townhouse that has meter bank instead of single meters attached to the units. Only Licensed Electrical Contractors can do work in Manufactured Home Parks. RESIDENTIAL FEES: New Construction: $135.00 + $1.00 State Surcharge (up to three trips) Repairs: + $1.00 State Surcharge (one trip) Additions, Remodel, Lower Level: $70.00 + $1.00 State Surcharge (two trips) COMMERCIAL FEES: Minimum of + $1.00 State Surcharge (one trip)---Remodel Minimum $70.00+$1.00 State Surcharge (two trips) JOB COST: $ Example: $12,000 Job Cost 1-1/2% of contract cost up to $10,000 $10,000.00 x 1.5% = $150.00 1% of cost above $10,000 plus surcharge + $ 2,000.00 x 1% = + 20.00 (Surcharge = Contract Cost x .0005) + $12,000 x.0005 = + 6.00 TOTAL = = $176.00 I hereby apply for an electrical permit and I acknowledge that the information above is complete and accurate; that the work will be in conformance with the ordinances and codes of the City of Lakeville and with the Minnesota Electrical Act; that I understand this is not a permit but only an application for a permit and work is not to start without a permit; that the work will be in accordance with the approved plan in the case of all work which requires review and approval of plans. NAME OF APPLICANT (Please Print) SIGNATURE OF APPLICANT: PLEASE NOTE: SEPARATE PERMITS ARE REQUIRED FOR ANY BUILDING, MECHANICAL & PLUMBING WORK www.lakevillemn.gov $40.00 $40.00 DETAILED DESCRIPTION OF WORK: $0.00 0.00 19344 Huxley Avenue, Lakeville, MN 55044 Stegge, Timothy (Tim) x Stegge, Timothy (Tim) 19344 Huxley Avenue Lakeville MN 55044 651-245-0113 installing 7.68 kW roof mount solar system FOR OFFICE USE ONLY: TYPE OF WORK INSPECTIONS NEW FINAL ADDITION FIRE ACCEPTANCE TEST ALTER/REMODEL IN FOOR HEAT ROUGH-IN SERVICE TRENCH PERMIT FEE PERMIT FEE: $ SURCHARGE: $ OTHER: $ TOTAL: $ PERMIT ISSUED BY: DATE: 0.00 COMMENTS: