Loading...
HomeMy WebLinkAboutLA186552 - Approved plansCOMPANY INFORMATION CLIENT INFORMATION SYSTEM DETAILS PROJECT-PAGE TITLE ALL ENERGY SOLAR, INC 1264 ENERGY LANE ST PAUL, MN 55108 (800) 620-3370 INFO@ALLENERGYSOLAR.COM PAGE NUMBER A0 REVISIONS LAST: 11/23/20 BX AZIMUTH NOTES: 1. (30) ENPHASE IQ7PLUS INVERTER(S) 2. ARRAY 1: 33° TILT, 180° AZIMUTH 3. ARRAY 2: (Array 2 Tilt)° TILT, (Array 2 Azimuth)° AZIMUTH 6. ARRAY 3: (Array 3 Tilt)° TILT, (Array 3 Azimuth)° AZIMUTH 7. ARRAY 4: (Array 4 Tilt)° TILT, (Array 4 Azimuth)° AZIMUTH COVER PAGE MICHELLE BIGGS 19751 HENNING AVE LAKEVILLE, MN 55044 PO 39974 N HENNING AVE ARRAY 1 REC 365 30 FLUSH ROOF MOUNT 10.95 Panel Type # of Panels System Size (kW) COMPANY INFORMATION CLIENT INFORMATION SYSTEM DETAILS PROJECT-PAGE TITLE ALL ENERGY SOLAR, INC 1264 ENERGY LANE ST PAUL, MN 55108 (800) 620-3370 INFO@ALLENERGYSOLAR.COM PAGE NUMBER A1 REVISIONS LAST: 11/23/20 BX AZIMUTH ACCOUNT: 200010016138 PREMISE: METER: I077072999 PROPERTY MAP N MICHELLE BIGGS 19751 HENNING AVE LAKEVILLE, MN 55044 PO 39974 NOTES: 1. (30) ENPHASE IQ7PLUS INVERTER(S) = 8.7kW AC 2. ARRAY 1: 180° AZIMUTH, 33° TILT (30) REC 365W = 10.95kW 3. ARRAY 2: (Array 2 Azimuth)° AZIMUTH, (Array 2 Tilt)° TILT ((Array 2 Panel Qty)) REC 365W = (Array 2 kW)kW 4. ARRAY 3: (Array 3 Azimuth)° AZIMUTH, (Array 3 Tilt)° TILT ((Array 3 Panel Qty)) REC 365W = (Array 3 kW)kW 5. ARRAY 4: (Array 4 Azimuth)° AZIMUTH, (Array 4 Tilt)° TILT ((Array 4 Panel Qty)) REC 365W = (Array 4 kW)kW ARRAY 1 HENNING AVE BOS SOLAR MODULES COVER ~21% OF ROOF PLAN FIRE CODE ACCESS PATHWAYS COMPANY INFORMATION CLIENT INFORMATION SYSTEM DETAILS PROJECT-PAGE TITLE ALL ENERGY SOLAR, INC 1264 ENERGY LANE ST PAUL, MN 55108 (800) 620-3370 INFO@ALLENERGYSOLAR.COM PAGE NUMBER A2 REVISIONS LAST: 11/23/20 BX NOTES: 1. ELEVATIONS MAY VARY DEPENDING ON GROUND ELEVATION BUT ARE DRAWN TO THE BEST OF OUR ABILITY 2. 2x4 TRUSS 24" OC ELEVATION DRAWINGS MICHELLE BIGGS 19751 HENNING AVE LAKEVILLE, MN 55044 PO 39974 SETBACKS: 18" FROM RIDGE 36" FROM EDGE SOUTH ELEVATION WEST ELEVATION FIRE CODE ACCESS PATHWAYS 34'-9"33'-7"25'-2"24'-0" COMPANY INFORMATION CLIENT INFORMATION SYSTEM DETAILS PROJECT-PAGE TITLE ALL ENERGY SOLAR, INC 1264 ENERGY LANE ST PAUL, MN 55108 (800) 620-3370 INFO@ALLENERGYSOLAR.COM PAGE NUMBER A3 REVISIONS LAST: 11/23/20 BX AZIMUTH ACCOUNT: 200010016138 PREMISE: METER: I077072999 SITE MAP N MICHELLE BIGGS & DAVID BIGGS 19751 HENNING AVE LAKEVILLE, MN 55044 PO 39974 NOTES: 1. (30) ENPHASE IQ7PLUS INVERTER(S) = 8.7kW AC 2. ARRAY 1: 180° AZIMUTH, 33° TILT (30) REC 365W = 10.95kW 3. ARRAY 2: (Array 2 Azimuth)° AZIMUTH, (Array 2 Tilt)° TILT ((Array 2 Panel Qty)) REC 365W = (Array 2 kW)kW 4. ARRAY 3: (Array 3 Azimuth)° AZIMUTH, (Array 3 Tilt)° TILT ((Array 3 Panel Qty)) REC 365W = (Array 3 kW)kW 5. ARRAY 4: (Array 4 Azimuth)° AZIMUTH, (Array 4 Tilt)° TILT ((Array 4 Panel Qty)) REC 365W = (Array 4 kW)kW NOTES: 1. LOCATION OF SERVICE PANEL AND ELECTRICAL EQUIPMENT ARE SHOWN. FINAL LOCATION MAY CHANGE 2. LOCATION OF SERVICE PANEL AND ADDITIONAL ELECTRICAL EQUIPMENT NOT DRAWN TO SCALE 3. PV INTERCONNECTION IS A SECONDARY INTERCONNECTION 4. AC DISCONNECT AND PRODUCTION METER IN READILY ACCESSIBLE LOCATION WITHIN 10' OF MAIN SERVICE METER/BI-DIRECTIONAL METER. 24/7 UNESCORTED KEYLESS ACCESS TO BE PROVIDED FOR UTILITY AC DISCONNECT, PV PRODUCTION METER, & BI- DIRECTIONAL METER. 5. PV EQUIPMENT SHALL BE INSTALLED IN ACCORDANCE WITH NEC 690 AND POSTED WITH APPLICABLE WARNINGS, SIGNAGE, AND PLAQUES PER NEC 705-10, 690-17, & 690-64 (b)(5). 6. CIRCUITS: (3) CIRCUIT(S) OF 10 (20AMPS EACH) ((Qty of circuits with the number of inverters optimizers above)) CIRCUIT(S) OF (Qty of inverters/optimizers in a circuit/string) ([Amps] (If Enphase. Based on 15 or 20A breakers)AMPS EACH) ((Qty of circuits with the number of inverters optimizers above)) CIRCUIT(S) OF (Qty of inverters/optimizers in a circuit/string) ([Amps] (If Enphase. Based on 15 or 20A breakers)AMPS EACH) ((Qty of circuits with the number of inverters optimizers above)) CIRCUIT(S) OF (Qty of inverters/optimizers in a circuit/string) ([Amps] (If Enphase. Based on 15 or 20A breakers)AMPS EACH) ((Qty of circuits with the number of inverters optimizers above)) CIRCUIT(S) OF (Qty of inverters/optimizers in a circuit/string) ([Amps] (If Enphase. Based on 15 or 20A breakers)AMPS EACH) 1 2 3 4 5 6 LABELS LOCATED ON PV PRODUCTION METER, BI- DIRECTIONAL METER, AC DISCONNECT(S), INVERTER(S), AND APPROPRIATE LABELS ON MAIN ELECTRIC SERVICE. ALL LABELS ARE PERMANENT, WEATHERPROOF, AND DURABLE THERE ARE NO CLEARANCE ISSUES DUE TO OVERHEAD POWERLINES. CALL-OUTS: 1: SOLAR PANELS 2: INVERTERS 3: ENPHASE IQ COMBINER PANEL 4: UTILITY AC DISCONNECT 5: PV PRODUCTION METER 6: MAIN ELECTRIC SERVICE 7: BI-DIRECTIONAL METER 8: OFF PEAK METER DISTANCES SOLAR PANELS - INVERTERS: 5' MAX INVERTERS - IQ COMBINER PANEL: 75' MAX IQ COMBINER PANEL - UTILITY AC DISCONNECT: 2' UTILITY AC DISCONNECT - PV PRODUCTION METER: 2' PV PRODUCTION METER - MAIN ELECTRIC SERVICE: 5' MAIN ELECTRIC SERVICE - BI-DIRECTIONAL METER: 5' 7 <10'80' HIBBING WAY HENNING AVE ARRAY 1 8 COMPANY INFORMATION CLIENT INFORMATION SYSTEM DETAILS PROJECT-PAGE TITLE ALL ENERGY SOLAR, INC 1264 ENERGY LANE ST PAUL, MN 55108 (800) 620-3370 INFO@ALLENERGYSOLAR.COM PAGE NUMBER A4 REVISIONS LAST: 11/23/20 BX *STRINGING TO BE DETERMINED ON SITE 2x4 TRUSS 24" OC RAIL AND STRINGING DIAGRAM AZIMUTH <aCustName(s)> <aCustAddress1> <aCustAddress2> <aCustAddress3> PO <aCustPONumber> N MICHELLE BIGGS 19751 HENNING AVE LAKEVILLE, MN 55044 PO 39974 SNAP-N-RACKSNR FLASHING MODULE 2x4 TRUSS 24" OC (30) REC REC365AA MODULES (30) ENPHASE IQ7PLUS INVERTER(S) CIRCUITS: (3) CIRCUIT(S) OF 10 MICROS ((Qty of circuits with the number of inverters optimizers above)) CIRCUIT(S) OF (Qty of inverters/optimizers in a circuit/string) MICROS ((Qty of circuits with the number of inverters optimizers above)) CIRCUIT(S) OF (Qty of inverters/optimizers in a circuit/string) MICROS ((Qty of circuits with the number of inverters optimizers above)) CIRCUIT(S) OF (Qty of inverters/optimizers in a circuit/string) MICROS ((Qty of circuits with the number of inverters optimizers above)) CIRCUIT(S) OF (Qty of inverters/optimizers in a circuit/string) MICROS SNAP-N-RACK MOUNTING HARDWARE: 1. (73) L-FEET 2. (10) RAIL SPLICES 3. CLAMPS (48) MIDCLAMPS (24) ENDCLAMPS 4. RAIL LENGTHS: (20) 168" RAILS LEGEND: TERM CAP: OPEN END: MAX CIRCUIT LENGTH (120/240V) 15A BREAKER 20A BREAKER ENPHASE IQ7 12 16 ENPHASE IQ7+9 13 ENPHASE IQ7X 9 12 ENPHASE IQ7A 8 11 102"39'-9"98" 31" 14'-9" 18" 36" ROOFTECH MINI ATTACHMENTS FIRE CODE ACCESS PATHWAYS COMPANY INFORMATION CLIENT INFORMATION SYSTEM DETAILS PROJECT-PAGE TITLE ALL ENERGY SOLAR, INC 1264 ENERGY LANE ST PAUL, MN 55108 (800) 620-3370 INFO@ALLENERGYSOLAR.COM PAGE NUMBER A5 REVISIONS LAST: 11/23/20 BX *DISTANCES NOT TO SCALE SYSTEM SIZE: 10.95kW DC MAXIMUM POWER: 8.7 kW AC OPERATING VOLTAGE: 120/240V MAXIMUM CURRENT: 36.3A ACCOUNT: 200010016138 PREMISE: METER: I077072999 NOTES: 1. DESIGN MEETS NEC CODE AND SHALL BE INSTALLED IN ACCORDANCE WITH NEC 690 AND POSTED WITH APPLICABLE WARNINGS, SIGNAGE, AND PLAQUES PER NEC 705-10, 690- 17, & 690-64 (b) (5) 2. SOLAR MODULES, INVERTERS, AND CORRESPONDING ELECTRICAL EQUIPMENT ARE LISTED. 3. INVERTERS ARE UL 1741 LISTED 4. PV INTERCONNECTION IS A SECONDARY INTERCONNECTION ELECTRICAL LINE DIAGRAM TO UTILITY MICHELLE BIGGS & DAVID BIGGS 19751 HENNING AVE LAKEVILLE, MN 55044 PO 39974 5' MAX ENPHASE IQ COMBINER PANEL 120/240V: 125A: 1 PHASE PLACARD INDICATING "NO LOAD TO BE SERVED" SEE LABEL(S) 10, 13, 14, 16, 19 ON FOLLOWING PAGES UTILITY AC DISCONNECT VISIBLE-OPEN TYPE, LOCKABLE, READILY ACCESSIBLE 1 PHASE, 60A, 120/240V SEE LABEL(S) 10, 14, 15, 16, 18, 19, 20 ON FOLLOWING PAGES 5' EXISTING CONDUIT AC DC 2' MAX 3/4" EMT: (2) #8 THWN (1) #10 NEUTRAL (1) #10 GROUND SQUARE D LOAD PANEL SEE LABEL(S) 14, 16, 35, 36, 37 ON FOLLOWING PAGES 120/240V 225A RATED BUS 200A MAIN 50A REC REC365AA RATED POWER AT STC:365W VMP:37.10V IMP:9.85A VOC:44.00V ISC:10.52A MODULE DETAILS: (30) (30) REC REC365AA 10.95kW (30) ENPHASE IQ7PLUS 120/240V (3) CIRCUIT(S) OF 10 (20A EA) ((Qty of circuits with the number of inverters optimizers above)) CIRCUIT(S) OF (Qty of inverters/optimizers in a circuit/string) ([Amps] (If Enphase. Based on 15 or 20A breakers)A EA) ((Qty of circuits with the number of inverters optimizers above)) CIRCUIT(S) OF (Qty of inverters/optimizers in a circuit/string) ([Amps] (If Enphase. Based on 15 or 20A breakers)A EA) ((Qty of circuits with the number of inverters optimizers above)) CIRCUIT(S) OF (Qty of inverters/optimizers in a circuit/string) ([Amps] (If Enphase. Based on 15 or 20A breakers)A EA) ((Qty of circuits with the number of inverters optimizers above)) CIRCUIT(S) OF (Qty of inverters/optimizers in a circuit/string) ([Amps] (If Enphase. Based on 15 or 20A breakers)A EA) INVERTER DETAILS: ENPHASE IQ7PLUS-72-2-US Rating: 290 W CEC Weighted Efficiency: 97 % Max DC Voltage: 60.V V Max AC Output Current: 1.21 A Nominal Voltage Range: 240V / 211-264V (1-Phase) Nominal Frequency: 60 Hz DAKOTA ELECTRIC ASSOCIATION BI-DIRECTIONAL METER 120/240V, 1-PHASE, 3-WIRE SEE LABEL(S) 41, 42, 43 ON FOLLOWING PAGES 75' MAX 3/4" EMT: (6) #10 THWN (1) #10 GROUND 2' MAX 3/4" EMT: (2) #6 THWN (1) #6 NEUTRAL (1) #10 GROUND 5' MAX 3/4" EMT: (2) #6 THWN (1) #6 NEUTRAL (1) #10 GROUND DAKOTA ELECTRIC ASSOCIATION PRODUCTION METER 120/240V, 200A WITH BYPASS 1-PHASE, 3-WIRE SEE LABEL(S) 21 ON FOLLOWING PAGES LINE/ TOP LOAD/ BOTTOM COMPANY INFORMATION CLIENT INFORMATION SYSTEM DETAILS PROJECT-PAGE TITLE ALL ENERGY SOLAR, INC 1264 ENERGY LANE ST PAUL, MN 55108 (800) 620-3370 INFO@ALLENERGYSOLAR.COM PAGE NUMBER A6 REVISIONS LAST: 11/23/20 BX LABELS ARE WEATHERPROOF, DURABLE, PERMANENTLY MOUNTED, AND COMPLY WITH NEC 690 ACCOUNT: 200010016138 PREMISE: METER: I077072999 LABELS MICHELLE BIGGS & DAVID BIGGS 19751 HENNING AVE LAKEVILLE, MN 55044 PO 39974 COMPANY INFORMATION CLIENT INFORMATION SYSTEM DETAILS PROJECT-PAGE TITLE ALL ENERGY SOLAR, INC 1264 ENERGY LANE ST PAUL, MN 55108 (800) 620-3370 INFO@ALLENERGYSOLAR.COM PAGE NUMBER A7 REVISIONS LAST: 11/23/20 BX LABELS 2 LABELS ARE WEATHERPROOF, DURABLE, PERMANENTLY MOUNTED, AND COMPLY WITH NEC 690 ACCOUNT: 200010016138 PREMISE: METER: I077072999 43 18 HOUSE SERVICE DISCONNECT (INSIDE) MICHELLE BIGGS & DAVID BIGGS 19751 HENNING AVE LAKEVILLE, MN 55044 PO 39974 CAUTION:MULTIPLE SOURCES OF POWER: N All Energy Solar www.allenergysolar.com (800) 620-3370 SOLAR ARRAY PV DISCONNECT PV COMBINER PANEL INTERCONNECTION DISCONNECT SWITCH 17 DUAL POWER SOURCE PHOTOVOLTAIC CIRCUIT Operating Voltage: 120/240 Maximum Current: 36.3 Amps Maximum Power: 8.7 KW MAXIMUM VOLTAGE MAXIMUM CIRCUIT CURRENT MAX RATED OUTPUT CURRENT OF THE CHARGE CONTROLLER OR DC-TO-DC CONVERTER (IF INSTALLED) 22 P H O T O V O L T A I C D C D I S C O N N E C T 23