Loading...
HomeMy WebLinkAbout18221 Hamel Drive SurveyLot 15, Block 1, PINNACLE RESERVE AT AVONLEA 3RD ADDITION, DakotaCounty, MinnesotaPROPERTY DESCRIPTIONSURVEYOR'S CERTIFICATEDenotes set spikeDenotes set iron monumentDenotes found iron monumentDenotes proposed drainageDenotes top of curbDenotes existing elevationDenotes proposed elevationPHONE: 952.890.6044 www.jrhinc.com PLANNERS / ENGINEERS / SURVEYORS CERTIFICATE OF SURVEY FORDRAWN BYDATEREVISIONSPLM/NDGCAD FILEPROJECT NO.SHEET 1 OF 1Lot 15, Block 1, PINNACLE RESERVE AT AVONLEA 3RD ADDITION, Dakota County, MinnesotaI hereby certify that this survey, plan or report was prepared by me or undermy direct supervision and that I am a duly Licensed Land Surveyor under thelaws of the State of Minnesota. That this survey does not purport to show allimprovements, easements or encroachments, to the property except asshown thereon.Signed this 19th day of February, 2021Marcus F. Hampton, MN L.S. No. 474812/19/2021410228.dwg4102282999 WEST C.R. 42, SUITE 100, BURNSVILLE, MN 553061. Bearings are based on the recorded plat.2. Building dimensions shown are for horizontal and vertical placement ofstructure only. See architectural plans for building and foundationdimensions.3. No specific soils investigation has been completed on this lot by JamesR. Hill, Inc. the suitability of soils to support the specific house proposedis not the responsibility of James R. Hill, Inc. or the surveyor.4. No specific title search for existence or non-existence of recorded orun-recorded easements has been conducted by the surveyor as a partof this survey. Only easements per the recorded plat are shown.5. Proposed grades shown were taken from the grading &/ordevelopment plan prepared by Westwood Professional Services, Inc.6. Grading plan date/revision date: October 5, 20207. Plan No. 5470-B 'JORDAN'NOTES18221 Hamel Drive, Lakeville, MinnesotaPROPERTY ADDRESSLot = 10,375 sq. ft.House/Garage = 2,246 sq. ft.Porch = 114 sq. ft.Driveway = 753 sq. ft.Sidewalk = 59 sq. ft.Total Impervious = 3,172 sq. ft. or 30.5% of lotHARD COVER CALCULATIONSProposedGarage Floor @ Front = 1019.4Garage Top of Block = 1019.8House Top of Block = 1019.8Lowest Floor = 1011.8Top of Block at Egress Window = 1015.0FLOOR ELEVATIONSTop nut of hydrant located at Lots 15 and 16, Block 1 = 1017.72BENCHMARKPlanning DepartmentApprovedDate:__________________03/12/2021dmorey*Draintile connection required.ENGINEERING REVIEWEDDate:__________________03/12/2021lvlasatyThe curb box, drain tile cleanout, and catchbasin(if applicable) must be inspected andaccepted before As-Built escrow monies willbe released. All structures must be flushwith the sod. This will be scheduled with thelandscape inspection.*Maintain 6" between bottom of siding and sod.*No structures in easements.EROSION CONTROL MUST BE INSTALLED BEFORE EXCAVATION