Loading...
HomeMy WebLinkAboutLA188588 9185 187th St W Permit PackRESIDENTIAL BUILDING PERMIT APPLICATION PAGE 2 OFFICE USE ONLY BUILDING PERMIT TYPE REQUIRED INSPECTIONS SINGLE FAMILY DWELLING BUILDING DUPLEX AS BUILT TOWNHOUSE UNITS BUILDING FINAL DETACHED TOWN HOUSE UNIT DECK FOOTING CONDO FIREPLACE ACESSORY BUILDING FOOTING REROOF FOUNDATION RESIDE FRAMING PORCH FRAMING GARAGES INSULATION RES ADDN/REPAIR/RMDL DECK PORCH GARAGES LATH LOWER LEVEL FINISH LOWER LEVEL FINAL ADDITION OTHER FOUNDATION ONLY PORCH FOOTING MISCELLANEOUS POURED WALL DEMO SEPTIC TANK REMOVAL MOVED SITE MECHANICAL CITY BUILDING VALUATION: $AIR TEST FINAL BUILDING PERMIT FEES ROUGH-IN $PERMIT FEE PLUMBING $PLAN CHECK FINAL $SURCHARGE ROUGH-IN $METRO SAC METER SIZE $CITY WATER HOOKUP UNIT PRESSURE REDUCING VALVE $CITY SEWER HOOKUP UNIT SEWER/WATER $LANDSCAPE ESCROW SEWER/WATER $TREE ESCROW FINAL $MISC ESCROW STREET DRAINTILE $PLUMBING BUILDING INFORMATION $MECHANICAL TYPE OF CONSTRUCTION $SEWER WATER ZONING $OTHER CODE EDITION $TOTAL FIRE SUPPRESSION SYSTEM OCCUPANCY GROUP APPROVED BY: BUILDING INSPECTOR: Date: PLUMBING/MECHANICAL INSPECTOR: Date: COMMENTS: 20195 Holyoke Avenue, Lakeville, MN 55044 952-985-4400  952-985-4499 fax www.lakevillemn.gov Sewer & Water Tie Card Address:________________________________________ Contractor:______________________________________ Permit Number:__________________________________ Final Date:________________ Street Drain-Tile:______ Size of Water Service: 1” Comments: AIRTEST SANITARY OVER 20’/2 FITTINGS THIS CARD MUST BE COMPLETED AND ON-SITE AT TIME OF SEWER & WATER INSPECTION Secure door closed until deck isconstructed with a separate permit.Concept Approval ONLYSubject to Field InspectionInspectorDate2020MN BldgCode03/05/2021dmathews UFER Ground-Provide 20' Rebar in footing and stubup near electrical service panel.-6/4 nailing on front and back walls-4" o.c. around openings on front and back walls. Temper ifwithin 60"of tub floor.PFHPFHPFHPFH-6/4 nailing on front and back walls-4" o.c. around openings on front and back walls.-6/4 nailing on front and back walls-4" o.c. around openings on front and back walls.-Min. 15" clearance to anyobstruction from center ofW.C., 24" in front(typ).CO Hebert Homes HVAC Load Calculations for Hebert Homes 9185 187th St W Lakeville,mn Prepared By: Randy Andrews Lofgren Heating 5708 Upper 147th Street West Apple Vallley, MN 55124 Monday, January 25, 2021 Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Lofgren Htg. & A/C Hebert Homes Farmington, MN 55024 Page 2 Project Report General Project Information Project Title:Hebert Homes Project Date:Monday, January 25, 2021 Client Name:Hebert Homes Client Address:9185 187th St W Client City:Lakeville,mn Company Name:Lofgren Heating Company Representative:Randy Andrews Company Address:5708 Upper 147th Street West Company City:Apple Vallley, MN 55124 Company E-Mail Address:rrandrews@lofgrenheating-ac.com Design Data Reference City:Minneapolis, Minnesota Building Orientation:Front door faces Southeast Daily Temperature Range:Medium Latitude:44 Degrees Elevation:834 ft. Altitude Factor:0.970 Elevation Sensible Adj. Factor:1.000 Elevation Total Adj. Factor:1.000 Elevation Heating Adj. Factor:1.000 Elevation Heating Adj. Factor:1.000 Outdoor Outdoor Outdoor Indoor Indoor Grains Dry Bulb Wet Bulb Rel.Hum Rel.Hum Dry Bulb Difference Winter:-15 -15.33 80%n/a 72 n/a Summer:88 72 47%50%75 29 Check Figures Total Building Supply CFM:997 CFM Per Square ft.:0.283 Square ft. of Room Area:3,524 Square ft. Per Ton:1,467 Volume (ft³) of Cond. Space:31,716 Building Loads Total Heating Required Including Ventilation Air:44,835 Btuh 44.835 MBH Total Sensible Gain:21,616 Btuh 81 % Total Latent Gain:5,114 Btuh 19 % Total Cooling Required Including Ventilation Air:26,730 Btuh 2.23 Tons (Based On Sensible + Latent) 2.40 Tons (Based On 75% Sensible Capacity) Notes Calculations are based on 8th edition of ACCA Manual J. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads. C:\ ...\9185 187TH ST LAKEVILLE 01252021.rhv Monday, January 25, 2021, 12:14 PM Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Lofgren Htg. & A/C Hebert Homes Farmington, MN 55024 Page 3 Load Preview Report Scope Has AED Net Ton ft.² /Ton Area Sen Gain Lat Gain Net Gain Sen Loss Sys Htg CFM Sys Clg CFM Sys Act CFM Duct Size Building 2.23 1,582 3,524 21,616 5,114 26,730 44,835 839 997 997 System 1 No 2.23 1,582 3,524 21,616 5,114 26,730 44,835 839 997 997 18x10 Ventilation 340 1,352 1,692 4,550 Zone 1 3,524 21,276 3,762 25,038 40,285 839 997 997 18x10 1-Upper Level 1,762 16,784 2,664 19,448 24,670 514 786 786 9--6 2-Lower Level 1,762 4,493 1,098 5,591 15,615 325 210 210 2--6 C:\ ...\9185 187TH ST LAKEVILLE 01252021.rhv Monday, January 25, 2021, 12:14 PM Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Lofgren Htg. & A/C Hebert Homes Farmington, MN 55024 Page 4 Total Building Summary Loads Component Description Area Quan Sen Loss Lat Gain Sen Gain Total Gain 4A-1a-o: Glazing-Double pane low-e (e = 0.20 or less), operable window, e=0.20 on surface 2, wood with metal clad frame, u-value 0.32, SHGC 0.33 311 8,659 0 7,925 7,925 11N: Door-Metal - Polystyrene Core 42 1,278 0 352 352 12F-0sw: Wall-Frame, R-21 insulation in 2 x 6 stud cavity, no board insulation, siding finish, wood studs 1843 10,423 0 1,593 1,593 15B0-10sf-10: Wall-Basement, , R-10 board insulation to floor, no interior finish, 10' floor depth 1188 5,065 0 0 0 16B-50: Roof/Ceiling-Under Attic with Insulation on Attic Floor (also use for Knee Walls and Partition Ceilings), Vented Attic, No Radiant Barrier, Dark Asphalt Shingles or Dark Metal, Tar and Gravel or Membrane, R-50 insulation 1762 3,066 0 1,692 1,692 21A-24-c: Floor-Basement, Concrete slab, any thickness, 2 or more feet below grade, no insulation below floor, carpet covering, shortest side of floor slab is 24' wide 1762 3,832 0 0 0 Subtotals for structure:32,323 0 11,562 11,562 People:7 1,400 1,610 3,010 Equipment:1,500 6,000 7,500 Lighting:0 0 0 Ductwork:0 0 0 0 Infiltration: Winter CFM: 86, Summer CFM: 45 7,962 862 619 1,481 Ventilation: Winter CFM: 140, Summer CFM: 70 4,550 1,352 340 1,692 AED Excursion:0 0 1,485 1,485 Total Building Load Totals:44,835 5,114 21,616 26,730 Check Figures Total Building Supply CFM:997 CFM Per Square ft.:0.283 Square ft. of Room Area:3,524 Square ft. Per Ton:1,467 Volume (ft³) of Cond. Space:31,716 Building Loads Total Heating Required Including Ventilation Air:44,835 Btuh 44.835 MBH Total Sensible Gain:21,616 Btuh 81 % Total Latent Gain:5,114 Btuh 19 % Total Cooling Required Including Ventilation Air:26,730 Btuh 2.23 Tons (Based On Sensible + Latent) 2.40 Tons (Based On 75% Sensible Capacity) Notes Calculations are based on 8th edition of ACCA Manual J. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads. C:\ ...\9185 187TH ST LAKEVILLE 01252021.rhv Monday, January 25, 2021, 12:14 PM Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Lofgren Htg. & A/C Hebert Homes Farmington, MN 55024 Page 5 Building Pie Chart Building Loss 44,835 Btuh Floor 9% Roof 7% Wall 35% Glass 19% Door 3% Infiltration 18% Ventilation 10% Building Gain 26,730 Btuh Roof 6% Wall 6% Glass 30% Door 1% People 11% Equipment 28% Infiltration 6% Ventilation 6% AED Excursion 6% C:\ ...\9185 187TH ST LAKEVILLE 01252021.rhv Monday, January 25, 2021, 12:14 PM Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Lofgren Htg. & A/C Hebert Homes Farmington, MN 55024 Page 6 System 1 Whole House Summary Loads Component Description Area Quan Sen Loss Lat Gain Sen Gain Total Gain 4A-1a-o: Glazing-Double pane low-e (e = 0.20 or less), operable window, e=0.20 on surface 2, wood with metal clad frame, u-value 0.32, SHGC 0.33 311 8,659 0 7,925 7,925 11N: Door-Metal - Polystyrene Core 42 1,278 0 352 352 12F-0sw: Wall-Frame, R-21 insulation in 2 x 6 stud cavity, no board insulation, siding finish, wood studs 1843 10,423 0 1,593 1,593 15B0-10sf-10: Wall-Basement, , R-10 board insulation to floor, no interior finish, 10' floor depth 1188 5,065 0 0 0 16B-50: Roof/Ceiling-Under Attic with Insulation on Attic Floor (also use for Knee Walls and Partition Ceilings), Vented Attic, No Radiant Barrier, Dark Asphalt Shingles or Dark Metal, Tar and Gravel or Membrane, R-50 insulation 1762 3,066 0 1,692 1,692 21A-24-c: Floor-Basement, Concrete slab, any thickness, 2 or more feet below grade, no insulation below floor, carpet covering, shortest side of floor slab is 24' wide 1762 3,832 0 0 0 Subtotals for structure:32,323 0 11,562 11,562 People:7 1,400 1,610 3,010 Equipment:1,500 6,000 7,500 Lighting:0 0 0 Ductwork:0 0 0 0 Infiltration: Winter CFM: 86, Summer CFM: 45 7,962 862 619 1,481 Ventilation: Winter CFM: 140, Summer CFM: 70 4,550 1,352 340 1,692 AED Excursion:0 0 1,485 1,485 System 1 Whole House Load Totals:44,835 5,114 21,616 26,730 Check Figures Supply CFM:997 CFM Per Square ft.:0.283 Square ft. of Room Area:3,524 Square ft. Per Ton:1,467 Volume (ft³) of Cond. Space:31,716 System Loads Total Heating Required Including Ventilation Air:44,835 Btuh 44.835 MBH Total Sensible Gain:21,616 Btuh 81 % Total Latent Gain:5,114 Btuh 19 % Total Cooling Required Including Ventilation Air:26,730 Btuh 2.23 Tons (Based On Sensible + Latent) 2.40 Tons (Based On 75% Sensible Capacity) Notes Calculations are based on 8th edition of ACCA Manual J. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads. C:\ ...\9185 187TH ST LAKEVILLE 01252021.rhv Monday, January 25, 2021, 12:14 PM Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Lofgren Htg. & A/C Hebert Homes Farmington, MN 55024 Page 7 Detailed Room Loads - Room 1 - Upper Level (Average Load Procedure) General Calculation Mode:Htg. & clg.Occurrences:1 Room Length:1,762.0 ft.System Number:1 Room Width:1.0 ft.Zone Number:1 Area:1,762.0 sq.ft.Supply Air:786 CFM Ceiling Height:9.0 ft.Supply Air Changes:3.0 AC/hr Volume:15,858.0 cu.ft.Req. Vent. Clg:0 CFM Number of Registers:9 Actual Winter Vent.:86 CFM Runout Air:87 CFM Percent of Supply.:11 % Runout Duct Size:6 in.Actual Summer Vent.:55 CFM Runout Air Velocity:445 ft./min.Percent of Supply:7 % Runout Air Velocity:445 ft./min.Actual Winter Infil.:66 CFM Actual Loss:0.124 in.wg./100 ft.Actual Summer Infil.:34 CFM Item Description Area Quantity -U- Value Htg HTM Sen Loss Clg HTM Lat Gain Sen Gain NW-Wall-12F-0sw 56 X 9 352 0.065 5.7 1,991 0.9 0 304 SE-Wall-12F-0sw 56 X 9 430 0.065 5.7 2,432 0.9 0 372 SW-Wall-12F-0sw 38 X 9 313 0.065 5.7 1,770 0.9 0 271 NE-Wall-12F-0sw 38 X 9 336 0.065 5.7 1,900 0.9 0 290 SE-Door-11N 3 X 7 21 0.350 30.5 639 8.4 0 176 SW-Door-11N 3 X 7 21 0.350 30.5 639 8.4 0 176 NW-Gls-4A-1a-o shgc-0.33 0%S 152 0.320 27.8 4,232 24.1 0 3,669 SE-Gls-4A-1a-o shgc-0.33 0%S 53 0.320 27.8 1,476 31.0 0 1,642 SW-Gls-4A-1a-o shgc-0.33 0%S 8 0.320 27.8 223 31.0 0 248 NE-Gls-4A-1a-o shgc-0.33 0%S 6 0.320 27.8 167 24.2 0 145 UP-Ceil-16B-50 1762 X 1 1762 0.020 1.7 3,066 1.0 0 1,692 Subtotals for Structure:18,535 0 8,985 Infil.: Win.: 66.1, Sum.: 34.4 1,692 3.626 6,135 0.282 664 477 AED Excursion:1,172 People: 200 lat/per, 230 sen/per:5 1,000 1,150 Equipment:1,000 5,000 Room Totals:24,670 2,664 16,784 C:\ ...\9185 187TH ST LAKEVILLE 01252021.rhv Monday, January 25, 2021, 12:14 PM Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Lofgren Htg. & A/C Hebert Homes Farmington, MN 55024 Page 8 Detailed Room Loads - Room 2 - Lower Level (Average Load Procedure) General Calculation Mode:Htg. & clg.Occurrences:1 Room Length:1,762.0 ft.System Number:1 Room Width:1.0 ft.Zone Number:1 Area:1,762.0 sq.ft.Supply Air:210 CFM Ceiling Height:9.0 ft.Supply Air Changes:0.8 AC/hr Volume:15,858.0 cu.ft.Req. Vent. Clg:0 CFM Number of Registers:2 Actual Winter Vent.:54 CFM Runout Air:105 CFM Percent of Supply.:26 % Runout Duct Size:6 in.Actual Summer Vent.:15 CFM Runout Air Velocity:536 ft./min.Percent of Supply:7 % Runout Air Velocity:536 ft./min.Actual Winter Infil.:20 CFM Actual Loss:0.179 in.wg./100 ft.Actual Summer Infil.:10 CFM Item Description Area Quantity -U- Value Htg HTM Sen Loss Clg HTM Lat Gain Sen Gain NW-Wall-12F-0sw 56 X 9 412 0.065 5.7 2,330 0.9 0 356 SE-Wall-15B0-10sf-10 56 X 9 504 0.049 4.3 2,149 0.0 0 0 SW-Wall-15B0-10sf-10 38 X 9 342 0.049 4.3 1,458 0.0 0 0 NE-Wall-15B0-10sf-10 38 X 9 342 0.049 4.3 1,458 0.0 0 0 NW-Gls-4A-1a-o shgc-0.33 0%S 92 0.320 27.8 2,561 24.1 0 2,221 Floor-21A-24 1 X 1762 1762 0.025 2.2 3,832 0.0 0 0 Subtotals for Structure:13,788 0 2,577 Infil.: Win.: 19.7, Sum.: 10.2 504 3.625 1,827 0.282 198 142 AED Excursion:314 People: 200 lat/per, 230 sen/per:2 400 460 Equipment:500 1,000 Room Totals:15,615 1,098 4,493 C:\ ...\9185 187TH ST LAKEVILLE 01252021.rhv Monday, January 25, 2021, 12:14 PM Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Lofgren Htg. & A/C Hebert Homes Farmington, MN 55024 Page 9 System 1 Room Load Summary No Room Name Area SF Htg Sens Btuh Min Htg CFM Run Duct Size Run Duct Vel Clg Sens Btuh Clg Lat Btuh Min Clg CFM Act Sys CFM ---Zone 1--- 1 Upper Level 1,762 24,670 514 9-6 445 16,784 2,664 786 786 2 Lower Level 1,762 15,615 325 2-6 536 4,493 1,098 210 210 Ventilation 4,550 340 1,352 System 1 total 3,524 44,835 839 21,616 5,114 997 997 System 1 Main Trunk Size:18x10 in. Velocity:797 ft./min Loss per 100 ft.:0.100 in.wg Cooling System Summary Cooling Tons Sensible/Latent Split Sensible Btuh Latent Btuh Total Btuh Net Required:2.23 81% / 19%21,616 5,114 26,730 Recommended:2.40 75% / 25%21,616 7,205 28,822 Actual:1.00 77% / 23%9,240 2,760 12,000 Equipment Data Heating System Cooling System Type:Natural Gas Furnace Standard Air Conditioner Model:QC-F38-E78-G QC-C12 Indoor Model:S12 Brand:Quikcool FE Series Quikcool AS Series Description:Hi Efficiency Furnace Standard Efficiency Air Condit Efficiency:78.3 AFUE 12.4 SEER Sound:8.1 bels Capacity:38,000 Btuh 12,000 Btuh Sensible Capacity:n/a 9,240 Btuh Latent Capacity:n/a 2,760 Btuh C:\ ...\9185 187TH ST LAKEVILLE 01252021.rhv Monday, January 25, 2021, 12:14 PM 02/25/21 X KP