HomeMy WebLinkAboutLA188588 9185 187th St W Permit PackRESIDENTIAL BUILDING PERMIT APPLICATION
PAGE 2
OFFICE USE ONLY
BUILDING PERMIT TYPE REQUIRED INSPECTIONS
SINGLE FAMILY DWELLING BUILDING
DUPLEX AS BUILT
TOWNHOUSE UNITS BUILDING FINAL
DETACHED TOWN HOUSE UNIT DECK FOOTING
CONDO FIREPLACE
ACESSORY BUILDING FOOTING
REROOF FOUNDATION
RESIDE FRAMING
PORCH FRAMING
GARAGES
INSULATION
RES ADDN/REPAIR/RMDL
DECK
PORCH
GARAGES LATH
LOWER LEVEL FINISH LOWER LEVEL FINAL
ADDITION OTHER
FOUNDATION ONLY PORCH FOOTING
MISCELLANEOUS POURED WALL
DEMO SEPTIC TANK REMOVAL
MOVED SITE
MECHANICAL
CITY BUILDING VALUATION: $AIR TEST
FINAL
BUILDING PERMIT FEES ROUGH-IN
$PERMIT FEE PLUMBING
$PLAN CHECK FINAL
$SURCHARGE ROUGH-IN
$METRO SAC METER SIZE
$CITY WATER HOOKUP UNIT PRESSURE REDUCING VALVE
$CITY SEWER HOOKUP UNIT SEWER/WATER
$LANDSCAPE ESCROW SEWER/WATER
$TREE ESCROW FINAL
$MISC ESCROW STREET DRAINTILE
$PLUMBING BUILDING INFORMATION
$MECHANICAL TYPE OF CONSTRUCTION
$SEWER WATER ZONING
$OTHER CODE EDITION
$TOTAL FIRE SUPPRESSION SYSTEM
OCCUPANCY GROUP
APPROVED BY:
BUILDING INSPECTOR: Date:
PLUMBING/MECHANICAL
INSPECTOR: Date:
COMMENTS:
20195 Holyoke Avenue, Lakeville, MN 55044
952-985-4400 952-985-4499 fax
www.lakevillemn.gov
Sewer & Water Tie Card
Address:________________________________________
Contractor:______________________________________
Permit Number:__________________________________
Final Date:________________
Street Drain-Tile:______
Size of Water Service: 1”
Comments: AIRTEST SANITARY OVER 20’/2 FITTINGS
THIS CARD MUST BE COMPLETED AND ON-SITE AT TIME
OF SEWER & WATER INSPECTION
Secure door closed until deck isconstructed with a separate permit.Concept Approval ONLYSubject to Field InspectionInspectorDate2020MN BldgCode03/05/2021dmathews
UFER Ground-Provide 20' Rebar in footing and stubup near electrical service panel.-6/4 nailing on front and back walls-4" o.c. around openings on front and back walls.
Temper ifwithin 60"of tub floor.PFHPFHPFHPFH-6/4 nailing on front and back walls-4" o.c. around openings on front and back walls.-6/4 nailing on front and back walls-4" o.c. around openings on front and back walls.-Min. 15" clearance to anyobstruction from center ofW.C., 24" in front(typ).CO
Hebert Homes
HVAC Load Calculations
for
Hebert Homes
9185 187th St W
Lakeville,mn
Prepared By:
Randy Andrews
Lofgren Heating
5708 Upper 147th Street West
Apple Vallley, MN 55124
Monday, January 25, 2021
Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc.
Lofgren Htg. & A/C Hebert Homes
Farmington, MN 55024 Page 2
Project Report
General Project Information
Project Title:Hebert Homes
Project Date:Monday, January 25, 2021
Client Name:Hebert Homes
Client Address:9185 187th St W
Client City:Lakeville,mn
Company Name:Lofgren Heating
Company Representative:Randy Andrews
Company Address:5708 Upper 147th Street West
Company City:Apple Vallley, MN 55124
Company E-Mail Address:rrandrews@lofgrenheating-ac.com
Design Data
Reference City:Minneapolis, Minnesota
Building Orientation:Front door faces Southeast
Daily Temperature Range:Medium
Latitude:44 Degrees
Elevation:834 ft.
Altitude Factor:0.970
Elevation Sensible Adj. Factor:1.000
Elevation Total Adj. Factor:1.000
Elevation Heating Adj. Factor:1.000
Elevation Heating Adj. Factor:1.000
Outdoor Outdoor Outdoor Indoor Indoor Grains
Dry Bulb Wet Bulb Rel.Hum Rel.Hum Dry Bulb Difference
Winter:-15 -15.33 80%n/a 72 n/a
Summer:88 72 47%50%75 29
Check Figures
Total Building Supply CFM:997 CFM Per Square ft.:0.283
Square ft. of Room Area:3,524 Square ft. Per Ton:1,467
Volume (ft³) of Cond. Space:31,716
Building Loads
Total Heating Required Including Ventilation Air:44,835 Btuh 44.835 MBH
Total Sensible Gain:21,616 Btuh 81 %
Total Latent Gain:5,114 Btuh 19 %
Total Cooling Required Including Ventilation Air:26,730 Btuh 2.23 Tons (Based On Sensible + Latent)
2.40 Tons (Based On 75% Sensible
Capacity)
Notes
Calculations are based on 8th edition of ACCA Manual J.
All computed results are estimates as building use and weather may vary.
Be sure to select a unit that meets both sensible and latent loads.
C:\ ...\9185 187TH ST LAKEVILLE 01252021.rhv Monday, January 25, 2021, 12:14 PM
Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc.
Lofgren Htg. & A/C Hebert Homes
Farmington, MN 55024 Page 3
Load Preview Report
Scope
Has
AED
Net
Ton
ft.²
/Ton Area
Sen
Gain
Lat
Gain
Net
Gain
Sen
Loss
Sys
Htg
CFM
Sys
Clg
CFM
Sys
Act
CFM
Duct
Size
Building 2.23 1,582 3,524 21,616 5,114 26,730 44,835 839 997 997
System 1 No 2.23 1,582 3,524 21,616 5,114 26,730 44,835 839 997 997 18x10
Ventilation 340 1,352 1,692 4,550
Zone 1 3,524 21,276 3,762 25,038 40,285 839 997 997 18x10
1-Upper Level 1,762 16,784 2,664 19,448 24,670 514 786 786 9--6
2-Lower Level 1,762 4,493 1,098 5,591 15,615 325 210 210 2--6
C:\ ...\9185 187TH ST LAKEVILLE 01252021.rhv Monday, January 25, 2021, 12:14 PM
Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc.
Lofgren Htg. & A/C Hebert Homes
Farmington, MN 55024 Page 4
Total Building Summary Loads
Component
Description
Area
Quan
Sen
Loss
Lat
Gain
Sen
Gain
Total
Gain
4A-1a-o: Glazing-Double pane low-e (e = 0.20 or less),
operable window, e=0.20 on surface 2, wood with
metal clad frame, u-value 0.32, SHGC 0.33
311 8,659 0 7,925 7,925
11N: Door-Metal - Polystyrene Core 42 1,278 0 352 352
12F-0sw: Wall-Frame, R-21 insulation in 2 x 6 stud
cavity, no board insulation, siding finish, wood studs
1843 10,423 0 1,593 1,593
15B0-10sf-10: Wall-Basement, , R-10 board insulation to
floor, no interior finish, 10' floor depth
1188 5,065 0 0 0
16B-50: Roof/Ceiling-Under Attic with Insulation on Attic
Floor (also use for Knee Walls and Partition
Ceilings), Vented Attic, No Radiant Barrier, Dark
Asphalt Shingles or Dark Metal, Tar and Gravel or
Membrane, R-50 insulation
1762 3,066 0 1,692 1,692
21A-24-c: Floor-Basement, Concrete slab, any thickness,
2 or more feet below grade, no insulation below floor,
carpet covering, shortest side of floor slab is 24' wide
1762 3,832 0 0 0
Subtotals for structure:32,323 0 11,562 11,562
People:7 1,400 1,610 3,010
Equipment:1,500 6,000 7,500
Lighting:0 0 0
Ductwork:0 0 0 0
Infiltration: Winter CFM: 86, Summer CFM: 45 7,962 862 619 1,481
Ventilation: Winter CFM: 140, Summer CFM: 70 4,550 1,352 340 1,692
AED Excursion:0 0 1,485 1,485
Total Building Load Totals:44,835 5,114 21,616 26,730
Check Figures
Total Building Supply CFM:997 CFM Per Square ft.:0.283
Square ft. of Room Area:3,524 Square ft. Per Ton:1,467
Volume (ft³) of Cond. Space:31,716
Building Loads
Total Heating Required Including Ventilation Air:44,835 Btuh 44.835 MBH
Total Sensible Gain:21,616 Btuh 81 %
Total Latent Gain:5,114 Btuh 19 %
Total Cooling Required Including Ventilation Air:26,730 Btuh 2.23 Tons (Based On Sensible + Latent)
2.40 Tons (Based On 75% Sensible
Capacity)
Notes
Calculations are based on 8th edition of ACCA Manual J.
All computed results are estimates as building use and weather may vary.
Be sure to select a unit that meets both sensible and latent loads.
C:\ ...\9185 187TH ST LAKEVILLE 01252021.rhv Monday, January 25, 2021, 12:14 PM
Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc.
Lofgren Htg. & A/C Hebert Homes
Farmington, MN 55024 Page 5
Building Pie Chart
Building
Loss
44,835
Btuh
Floor 9%
Roof 7%
Wall 35%
Glass 19%
Door 3%
Infiltration 18%
Ventilation 10%
Building
Gain
26,730
Btuh
Roof 6%
Wall 6%
Glass 30%
Door 1%
People 11%
Equipment 28%
Infiltration 6%
Ventilation 6%
AED Excursion 6%
C:\ ...\9185 187TH ST LAKEVILLE 01252021.rhv Monday, January 25, 2021, 12:14 PM
Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc.
Lofgren Htg. & A/C Hebert Homes
Farmington, MN 55024 Page 6
System 1 Whole House Summary Loads
Component
Description
Area
Quan
Sen
Loss
Lat
Gain
Sen
Gain
Total
Gain
4A-1a-o: Glazing-Double pane low-e (e = 0.20 or less),
operable window, e=0.20 on surface 2, wood with
metal clad frame, u-value 0.32, SHGC 0.33
311 8,659 0 7,925 7,925
11N: Door-Metal - Polystyrene Core 42 1,278 0 352 352
12F-0sw: Wall-Frame, R-21 insulation in 2 x 6 stud
cavity, no board insulation, siding finish, wood studs
1843 10,423 0 1,593 1,593
15B0-10sf-10: Wall-Basement, , R-10 board insulation to
floor, no interior finish, 10' floor depth
1188 5,065 0 0 0
16B-50: Roof/Ceiling-Under Attic with Insulation on Attic
Floor (also use for Knee Walls and Partition
Ceilings), Vented Attic, No Radiant Barrier, Dark
Asphalt Shingles or Dark Metal, Tar and Gravel or
Membrane, R-50 insulation
1762 3,066 0 1,692 1,692
21A-24-c: Floor-Basement, Concrete slab, any thickness,
2 or more feet below grade, no insulation below floor,
carpet covering, shortest side of floor slab is 24' wide
1762 3,832 0 0 0
Subtotals for structure:32,323 0 11,562 11,562
People:7 1,400 1,610 3,010
Equipment:1,500 6,000 7,500
Lighting:0 0 0
Ductwork:0 0 0 0
Infiltration: Winter CFM: 86, Summer CFM: 45 7,962 862 619 1,481
Ventilation: Winter CFM: 140, Summer CFM: 70 4,550 1,352 340 1,692
AED Excursion:0 0 1,485 1,485
System 1 Whole House Load Totals:44,835 5,114 21,616 26,730
Check Figures
Supply CFM:997 CFM Per Square ft.:0.283
Square ft. of Room Area:3,524 Square ft. Per Ton:1,467
Volume (ft³) of Cond. Space:31,716
System Loads
Total Heating Required Including Ventilation Air:44,835 Btuh 44.835 MBH
Total Sensible Gain:21,616 Btuh 81 %
Total Latent Gain:5,114 Btuh 19 %
Total Cooling Required Including Ventilation Air:26,730 Btuh 2.23 Tons (Based On Sensible + Latent)
2.40 Tons (Based On 75% Sensible
Capacity)
Notes
Calculations are based on 8th edition of ACCA Manual J.
All computed results are estimates as building use and weather may vary.
Be sure to select a unit that meets both sensible and latent loads.
C:\ ...\9185 187TH ST LAKEVILLE 01252021.rhv Monday, January 25, 2021, 12:14 PM
Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc.
Lofgren Htg. & A/C Hebert Homes
Farmington, MN 55024 Page 7
Detailed Room Loads - Room 1 - Upper Level (Average Load Procedure)
General
Calculation Mode:Htg. & clg.Occurrences:1
Room Length:1,762.0 ft.System Number:1
Room Width:1.0 ft.Zone Number:1
Area:1,762.0 sq.ft.Supply Air:786 CFM
Ceiling Height:9.0 ft.Supply Air Changes:3.0 AC/hr
Volume:15,858.0 cu.ft.Req. Vent. Clg:0 CFM
Number of Registers:9 Actual Winter Vent.:86 CFM
Runout Air:87 CFM Percent of Supply.:11 %
Runout Duct Size:6 in.Actual Summer Vent.:55 CFM
Runout Air Velocity:445 ft./min.Percent of Supply:7 %
Runout Air Velocity:445 ft./min.Actual Winter Infil.:66 CFM
Actual Loss:0.124 in.wg./100 ft.Actual Summer Infil.:34 CFM
Item
Description
Area
Quantity
-U-
Value
Htg
HTM
Sen
Loss
Clg
HTM
Lat
Gain
Sen
Gain
NW-Wall-12F-0sw 56 X 9 352 0.065 5.7 1,991 0.9 0 304
SE-Wall-12F-0sw 56 X 9 430 0.065 5.7 2,432 0.9 0 372
SW-Wall-12F-0sw 38 X 9 313 0.065 5.7 1,770 0.9 0 271
NE-Wall-12F-0sw 38 X 9 336 0.065 5.7 1,900 0.9 0 290
SE-Door-11N 3 X 7 21 0.350 30.5 639 8.4 0 176
SW-Door-11N 3 X 7 21 0.350 30.5 639 8.4 0 176
NW-Gls-4A-1a-o shgc-0.33 0%S 152 0.320 27.8 4,232 24.1 0 3,669
SE-Gls-4A-1a-o shgc-0.33 0%S 53 0.320 27.8 1,476 31.0 0 1,642
SW-Gls-4A-1a-o shgc-0.33 0%S 8 0.320 27.8 223 31.0 0 248
NE-Gls-4A-1a-o shgc-0.33 0%S 6 0.320 27.8 167 24.2 0 145
UP-Ceil-16B-50 1762 X 1 1762 0.020 1.7 3,066 1.0 0 1,692
Subtotals for Structure:18,535 0 8,985
Infil.: Win.: 66.1, Sum.: 34.4 1,692 3.626 6,135 0.282 664 477
AED Excursion:1,172
People: 200 lat/per, 230 sen/per:5 1,000 1,150
Equipment:1,000 5,000
Room Totals:24,670 2,664 16,784
C:\ ...\9185 187TH ST LAKEVILLE 01252021.rhv Monday, January 25, 2021, 12:14 PM
Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc.
Lofgren Htg. & A/C Hebert Homes
Farmington, MN 55024 Page 8
Detailed Room Loads - Room 2 - Lower Level (Average Load Procedure)
General
Calculation Mode:Htg. & clg.Occurrences:1
Room Length:1,762.0 ft.System Number:1
Room Width:1.0 ft.Zone Number:1
Area:1,762.0 sq.ft.Supply Air:210 CFM
Ceiling Height:9.0 ft.Supply Air Changes:0.8 AC/hr
Volume:15,858.0 cu.ft.Req. Vent. Clg:0 CFM
Number of Registers:2 Actual Winter Vent.:54 CFM
Runout Air:105 CFM Percent of Supply.:26 %
Runout Duct Size:6 in.Actual Summer Vent.:15 CFM
Runout Air Velocity:536 ft./min.Percent of Supply:7 %
Runout Air Velocity:536 ft./min.Actual Winter Infil.:20 CFM
Actual Loss:0.179 in.wg./100 ft.Actual Summer Infil.:10 CFM
Item
Description
Area
Quantity
-U-
Value
Htg
HTM
Sen
Loss
Clg
HTM
Lat
Gain
Sen
Gain
NW-Wall-12F-0sw 56 X 9 412 0.065 5.7 2,330 0.9 0 356
SE-Wall-15B0-10sf-10 56 X 9 504 0.049 4.3 2,149 0.0 0 0
SW-Wall-15B0-10sf-10 38 X 9 342 0.049 4.3 1,458 0.0 0 0
NE-Wall-15B0-10sf-10 38 X 9 342 0.049 4.3 1,458 0.0 0 0
NW-Gls-4A-1a-o shgc-0.33 0%S 92 0.320 27.8 2,561 24.1 0 2,221
Floor-21A-24 1 X 1762 1762 0.025 2.2 3,832 0.0 0 0
Subtotals for Structure:13,788 0 2,577
Infil.: Win.: 19.7, Sum.: 10.2 504 3.625 1,827 0.282 198 142
AED Excursion:314
People: 200 lat/per, 230 sen/per:2 400 460
Equipment:500 1,000
Room Totals:15,615 1,098 4,493
C:\ ...\9185 187TH ST LAKEVILLE 01252021.rhv Monday, January 25, 2021, 12:14 PM
Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc.
Lofgren Htg. & A/C Hebert Homes
Farmington, MN 55024 Page 9
System 1 Room Load Summary
No
Room
Name
Area
SF
Htg
Sens
Btuh
Min
Htg
CFM
Run
Duct
Size
Run
Duct
Vel
Clg
Sens
Btuh
Clg
Lat
Btuh
Min
Clg
CFM
Act
Sys
CFM
---Zone 1---
1 Upper Level 1,762 24,670 514 9-6 445 16,784 2,664 786 786
2 Lower Level 1,762 15,615 325 2-6 536 4,493 1,098 210 210
Ventilation 4,550 340 1,352
System 1 total 3,524 44,835 839 21,616 5,114 997 997
System 1 Main Trunk Size:18x10 in.
Velocity:797 ft./min
Loss per 100 ft.:0.100 in.wg
Cooling System Summary
Cooling
Tons
Sensible/Latent
Split
Sensible
Btuh
Latent
Btuh
Total
Btuh
Net Required:2.23 81% / 19%21,616 5,114 26,730
Recommended:2.40 75% / 25%21,616 7,205 28,822
Actual:1.00 77% / 23%9,240 2,760 12,000
Equipment Data
Heating System Cooling System
Type:Natural Gas Furnace Standard Air Conditioner
Model:QC-F38-E78-G QC-C12
Indoor Model:S12
Brand:Quikcool FE Series Quikcool AS Series
Description:Hi Efficiency Furnace Standard Efficiency Air Condit
Efficiency:78.3 AFUE 12.4 SEER
Sound:8.1 bels
Capacity:38,000 Btuh 12,000 Btuh
Sensible Capacity:n/a 9,240 Btuh
Latent Capacity:n/a 2,760 Btuh
C:\ ...\9185 187TH ST LAKEVILLE 01252021.rhv Monday, January 25, 2021, 12:14 PM
02/25/21 X
KP