Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
LA189704 Solar - Elec
1264 Energy Lane 55108 (651) 842-9404 Colin Buechel All Energy Solar 667674 St. Paul MN Installation of a flush mount solar array on the roof of the residence X Colin Buechel COMPANY INFORMATION CLIENT INFORMATION SYSTEM DETAILS PROJECT-PAGE TITLE ALL ENERGY SOLAR, INC 1264 ENERGY LANE ST PAUL, MN 55108 (800) 620-3370 INFO@ALLENERGYSOLAR.COM PAGE NUMBER A4 REVISIONS LAST: 04/8/21 BX AZIMUTH ACCOUNT: 200010034220 PREMISE: METER: 1ND89990969 SITE MAP N DARREN HOUSE 8826 191ST CT LAKEVILLE, MN 55044 PO 33132 NOTES: 1. (29) ENPHASE IQ7PLUS INVERTER(S) = 8.41kW AC 2. ARRAY 1: 180° AZIMUTH, 26° TILT (29) REC 365W = 10.585kW 3. ARRAY 2: (Array 2 Azimuth)° AZIMUTH, (Array 2 Tilt)° TILT ((Array 2 Panel Qty)) REC 365W = (Array 2 kW)kW 4. ARRAY 3: (Array 3 Azimuth)° AZIMUTH, (Array 3 Tilt)° TILT ((Array 3 Panel Qty)) REC 365W = (Array 3 kW)kW 5. ARRAY 4: (Array 4 Azimuth)° AZIMUTH, (Array 4 Tilt)° TILT ((Array 4 Panel Qty)) REC 365W = (Array 4 kW)kW NOTES: 1. LOCATION OF SERVICE PANEL AND ELECTRICAL EQUIPMENT ARE SHOWN. FINAL LOCATION MAY CHANGE 2. LOCATION OF SERVICE PANEL AND ADDITIONAL ELECTRICAL EQUIPMENT NOT DRAWN TO SCALE 3. PV INTERCONNECTION IS A SECONDARY INTERCONNECTION 4. AC DISCONNECT AND PRODUCTION METER IN READILY ACCESSIBLE LOCATION WITHIN 10' OF MAIN SERVICE METER/BI-DIRECTIONAL METER. 24/7 UNESCORTED KEYLESS ACCESS TO BE PROVIDED FOR UTILITY AC DISCONNECT, PV PRODUCTION METER, & BI-DIRECTIONAL METER. 5. PV EQUIPMENT SHALL BE INSTALLED IN ACCORDANCE WITH NEC 690 AND POSTED WITH APPLICABLE WARNINGS, SIGNAGE, AND PLAQUES PER NEC 705-10, 690-17, & 690-64 (b)(5). 6. CIRCUITS: (2) CIRCUIT(S) OF 8 (15AMPS EACH) (1) CIRCUIT(S) OF 13 (20AMPS EACH) ((Qty of circuits with the number of inverters optimizers above)) CIRCUIT(S) OF (Qty of inverters/optimizers in a circuit/string) ([Amps] (If Enphase. Based on 15 or 20A breakers)AMPS EACH) ((Qty of circuits with the number of inverters optimizers above)) CIRCUIT(S) OF (Qty of inverters/optimizers in a circuit/string) ([Amps] (If Enphase. Based on 15 or 20A breakers)AMPS EACH) ((Qty of circuits with the number of inverters optimizers above)) CIRCUIT(S) OF (Qty of inverters/optimizers in a circuit/string) ([Amps] (If Enphase. Based on 15 or 20A breakers)AMPS EACH) 1 2 3 4 5 6 CALL-OUTS: 1: SOLAR PANELS 2: INVERTERS 3: ENPHASE IQ COMBINER PANEL 4: UTILITY FUSED AC DISCONNECT 5: PV PRODUCTION METER 6: BI-DIRECTIONAL METER 7: MAIN ELECTRIC SERVICE DISTANCES SOLAR PANELS - INVERTERS: 5' MAX INVERTERS - IQ COMBINER PANEL: 75' MAX IQ COMBINER PANEL - UTILITY FUSED AC DISCONNECT: 2' UTILITY FUSED AC DISCONNECT - PV PRODUCTION METER: 2' PV PRODUCTION METER - BI-DIRECTIONAL METER: 2' BI-DIRECTIONAL METER - MAIN ELECTRIC SERVICE: 2' LABELS LOCATED ON PV PRODUCTION METER, BI- DIRECTIONAL METER, AC DISCONNECT(S), INVERTER(S), AND APPROPRIATE LABELS ON MAIN ELECTRIC SERVICE. ALL LABELS ARE PERMANENT, WEATHERPROOF, AND DURABLE THERE ARE NO CLEARANCE ISSUES DUE TO OVERHEAD POWERLINES. 7 <10'425' HUXLEY AVE 191ST CT ARRAY 1 COMPANY INFORMATION CLIENT INFORMATION SYSTEM DETAILS PROJECT-PAGE TITLE ALL ENERGY SOLAR, INC 1264 ENERGY LANE ST PAUL, MN 55108 (800) 620-3370 INFO@ALLENERGYSOLAR.COM PAGE NUMBER A5 REVISIONS LAST: 04/8/21 BX *DISTANCES NOT TO SCALE NOTES: 1. DESIGN MEETS NEC CODE AND SHALL BE INSTALLED IN ACCORDANCE WITH NEC 690 AND POSTED WITH APPLICABLE WARNINGS, SIGNAGE, AND PLAQUES PER NEC 705-10, 690- 17, & 690-64 (b) (5) 2. SOLAR MODULES, INVERTERS, AND CORRESPONDING ELECTRICAL EQUIPMENT ARE LISTED. 3. INVERTERS ARE UL 1741 LISTED 4. PV INTERCONNECTION IS A SECONDARY INTERCONNECTION SYSTEM SIZE: 10.585kW DC MAXIMUM POWER: 8.41 kW AC OPERATING VOLTAGE: 120/240V MAXIMUM CURRENT: 35.09A ACCOUNT: 200010034220 PREMISE: METER: 1ND89990969 ELECTRICAL LINE DIAGRAM TO UTILITY DARREN HOUSE 8826 191ST CT LAKEVILLE, MN 55044 PO 33132 AC DC UTILITY FUSED AC DISCONNECT VISIBLE-OPEN TYPE, LOCKABLE, READILY ACCESSIBLE 1 PHASE, 60A, 120/240V SEE LABEL(S) 10, 14, 15, 16, 20, 35 ON FOLLOWING PAGES 2' EXISTING CONDUIT 5' MAX LINETAP INSIDE MAIN ELECTRICAL PANEL VIA UL-LISTED POLARIS LUGS 120/240V 200A RATED BUS 200A MAIN EATON LOAD PANEL SEE LABEL(S) 18 ON FOLLOWING PAGES REC REC365AA RATED POWER AT STC:365W VMP:37.10V IMP:9.85A VOC:44.00V ISC:10.52A MODULE DETAILS: (29)50ADAKOTA ELECTRIC ASSOCIATION BI-DIRECTIONAL METER 120/240V, 1-PHASE, 3-WIRE SEE LABEL(S) 41, 42 ON FOLLOWING PAGES (29) REC REC365AA 10.585kW (29) ENPHASE IQ7PLUS 120/240V (2) CIRCUIT(S) OF 8 (15A EA) (1) CIRCUIT(S) OF 13 (20A EA) ((Qty of circuits with the number of inverters optimizers above)) CIRCUIT(S) OF (Qty of inverters/optimizers in a circuit/string) ([Amps] (If Enphase. Based on 15 or 20A breakers)A EA) ((Qty of circuits with the number of inverters optimizers above)) CIRCUIT(S) OF (Qty of inverters/optimizers in a circuit/string) ([Amps] (If Enphase. Based on 15 or 20A breakers)A EA) ((Qty of circuits with the number of inverters optimizers above)) CIRCUIT(S) OF (Qty of inverters/optimizers in a circuit/string) ([Amps] (If Enphase. Based on 15 or 20A breakers)A EA) INVERTER DETAILS: ENPHASE IQ7PLUS-72-2-US Rating: 290 W CEC Weighted Efficiency: 97 % Max DC Voltage: 60.V V Max AC Output Current: 1.21 A Nominal Voltage Range: 240V / 211-264V (1-Phase) Nominal Frequency: 60 Hz 75' MAX 3/4" EMT: (6) #10 THWN (1) #10 GROUND 2' MAX 3/4" EMT: (2) #8 THWN (1) #10 NEUTRAL (1) #10 GROUND [%]% VOLTAGE DROP [Trench distance]' MAX [Minimum 1]" PVC: (2) #[wire size] THWN (1) #10 NEUTRAL (1) #10 GROUND ENPHASE IQ COMBINER PANEL 120/240V 125A 1 PHASE PLACARD INDICATING "NO LOAD TO BE SERVED" SEE LABEL(S) 16, 18, 24 ON FOLLOWING PAGES 2' MAX 3/4" EMT: (2) #6 THWN (1) #6 NEUTRAL (1) #10 GROUND 2' MAX 3/4" EMT: (2) #6 THWN (1) #6 NEUTRAL (1) #10 GROUND DAKOTA ELECTRIC ASSOCIATION PRODUCTION METER 120/240V, 200A WITH BYPASS 1-PHASE, 3-WIRE SEE LABEL(S) 21 ON FOLLOWING PAGES LINE/ TOP LOAD/ BOTTOM COMPANY INFORMATION CLIENT INFORMATION SYSTEM DETAILS PROJECT-PAGE TITLE ALL ENERGY SOLAR, INC 1264 ENERGY LANE ST PAUL, MN 55108 (800) 620-3370 INFO@ALLENERGYSOLAR.COM PAGE NUMBER A6 REVISIONS LAST: 04/8/21 BX LABELS ARE WEATHERPROOF, DURABLE, PERMANENTLY MOUNTED, AND COMPLY WITH NEC 690 ACCOUNT: 200010034220 PREMISE: METER: 1ND89990969 LABELS DARREN HOUSE 8826 191ST CT LAKEVILLE, MN 55044 PO 33132 PHOTOVOLTAIC AC DISCONNECT MAXIMUM AC OPERATING CURRENT: NOMINAL OPERATING AC VOLTAGE: P H O T O V O L T A I C A C D I S C O N N E C T MAIN PHOTOVOLTAIC SYSTEM DISCONNECT CAUTION: SOLAR ELECTRIC SYSTEM CONNECTED ! WARNING DUAL POWER SOURCE SECOND SOURCE IS PHOTOVOLTAIC SYSTEM WARNING: PHOTOVOLTAIC POWER SOURCE WARNING! ELECTRICAL SHOCK HAZARD DO NOT TOUCH TERMINALS TERMINALS ON BOTH LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION RAPID SHUTDOWN SWITCH FOR SOLAR PV SYSTEM 16 13 15 41 42 14 5: EXPOSED DC CONDUIT, JUNCTION BOXES, ECT. 8: 10 HOUSE METER 21 PV PRODUCTION METER TURN RAPID SHUTDOWN SWITCH TO THE "OFF" POSITION TO SHUT DOWN PV SYSTEM AND REDUCE SHOCK HAZARD IN THE ARRAY SOLAR PV SYSTEM EQUIPPED WITH RAPID SHUTDOWN SOLAR ELECTRIC PV PANELS 35 MAXIMUM DC VOLTAGE OF PV SYSTEM 7 PHOTOVOLTAIC DC DISCONNECT 6 ! POWER SOURCE OUTPUT CONNECTION. DO NOT RELOCATE THIS OVERCURRENT DEVICE. WARNING PV SYSTEM CIRCUIT BREAKER IS BACKFED CAUTION 36 37 UTILITY AC DISCONNECT 20INTERCONNECTION DISCONNECT SWITCH 17 COMPANY INFORMATION CLIENT INFORMATION SYSTEM DETAILS PROJECT-PAGE TITLE ALL ENERGY SOLAR, INC 1264 ENERGY LANE ST PAUL, MN 55108 (800) 620-3370 INFO@ALLENERGYSOLAR.COM PAGE NUMBER A7 REVISIONS LAST: 04/8/21 BX LABELS 2 LABELS ARE WEATHERPROOF, DURABLE, PERMANENTLY MOUNTED, AND COMPLY WITH NEC 690 ACCOUNT: 200010034220 PREMISE: METER: 1ND89990969 43 18 DARREN HOUSE 8826 191ST CT LAKEVILLE, MN 55044 PO 33132 CAUTION:MULTIPLE SOURCES OF POWER: N All Energy Solar www.allenergysolar.com (800) 620-3370 SOLAR ARRAY PV COMBINER PANEL HOUSE SERVICE DISCONNECT (BASEMENT) MAIN PV DISCONNECT INTERCONNECTION DISCONNECT SWITCH 17 DUAL POWER SOURCE PHOTOVOLTAIC CIRCUIT Operating Voltage: 120/240 Maximum Current: 35.09 Amps Maximum Power: 8.41 KW MAXIMUM VOLTAGE MAXIMUM CIRCUIT CURRENT MAX RATED OUTPUT CURRENT OF THE CHARGE CONTROLLER OR DC-TO-DC CONVERTER (IF INSTALLED) 22 24 NOTICEPV COMBINER PANEL ONLY NO LOADS EMERGENCY DISCONNECT SERVICE DISCONNECT 15 α experience performance 375 wp Power rec Alphα black Series ELIGIBLE FOR www.recgroup.com 28 [1.1] 1721±2.5 [67.75 ±0.1] 802 [31.5]455 [17.9]975±2.5 [38.4±0.1]1016±2.5 [40 ±0.1]17 [0.7]45 [1.5] 1000 [39] 1200 [47] Scale: 1:1.57 11±0.2 [0.43 ±0.8]6.6±0.2 [0.26 ±0.08]20.5±0.5 [0.78 ±0.08] 30 [1.18] 22.5 [0.9] 621 ±3 [24.5 ±0.12] GR GR GR Ref: PM-DS-12-02-Rev- D2 07.20Specifications subject to change without notice.CERTIFICATIONS WARRANTY LOW LIGHT BEHAVIOUR TEMPERATURE RATINGS* MAXIMUM RATINGS Measurements in mm [in] 100 200 300 400 500 600 700 800 900 1000 85 90 95 100 105 Irradiance (W/m²) Typical low irradiance performance of module at STC:Rel. Efficiency (%)Nominal Module Operating Temperature:44°C (±2°C) Temperature coefficient of PMAX:-0.26 %/°C Temperature coefficient of VOC:-0.24 %/°C Temperature coefficient of ISC:0.04 %/°C *The temperature coefficients stated are linear values Operational temperature:-40 ... +85°C Maximum system voltage:1000 V Design load (+): snow Maximum test load (+): 4666 Pa (97.5 lbs/sq ft)+ 7000 Pa (146 lbs/sq ft)* Design load (-): wind Maximum test load (-): 2666 Pa (55.6 lbs/sq ft)+ 4000 Pa (83.5 lbs/sq ft)* Max series fuse rating:25 A Max reverse current:25 A + Calculated using a safety factor of 1.5 * See installation manual for mounting instructions IEC 61215:2016, IEC 61730:2016, UL 1703, UL 61730 IEC 62804 PID IEC 61701 Salt Mist IEC 62716 Ammonia Resistance UL 1703 Fire Type Class 2 IEC 62782 Dynamic Mechanical Load IEC 61215-2:2016 Hailstone (35mm) AS4040.2 NCC 2016 Cyclic Wind Load ISO 14001:2004, ISO 9001:2015, OHSAS 18001:2007, IEC 62941 Standard REC ProTrust Installed by an REC Certified Solar Professional No Yes Yes System Size All ≤25 kW 25-500 kW Product Warranty (yrs)20 25 25 Power Warranty (yrs)25 25 25 Labor Warranty (yrs)0 25 10 Power in Year 1 98%98%98% Annual Degradation 0.25%0.25%0.25% Power in Year 25 92%92%92% See warranty documents for details. Conditions apply. ELECTRICAL DATA Product Code*: RECxxxAA Black Power Output - PMAX (Wp) 355 360 365 370 375 Watt Class Sorting - (W)-0/+5 -0/+5 -0/+5 -0/+5 -0/+5 Nominal Power Voltage - VMPP (V) 36.4 36.7 37.1 37.4 37.8 Nominal Power Current - IMPP (A) 9.77 9.82 9.85 9.9 9.94 Open Circuit Voltage - VOC (V) 43.6 43.9 44.0 44.1 44.2 Short Circuit Current - ISC (A) 10.47 10.49 10.52 10.55 10.58 Power Density (W/sq ft)18.88 19.15 19.41 19.68 19.94 Panel Efficiency (%) 20.3 20.6 20.9 21.2 21.4 Power Output - PMAX (Wp)271 274 278 282 286 Nominal Power Voltage - VMPP (V) 34.3 34.6 35.0 35.2 35.6 Nominal Power Current - IMPP (A) 7.89 7.93 7.96 8.00 8.03 Open Circuit Voltage - VOC (V) 41.1 41.4 41.5 41.6 41.6 Short Circuit Current - ISC (A) 8.46 8.47 8.50 8.52 8.55 Values at standard test conditions (STC: air mass AM 1.5, irradiance 10.75 W/sq ft (1000 W/m²), temperature 77°F (25°C), based on a production spread with a tolerance of PMAX, VOC & ISC ±3% within one watt class. Nominal module operating temperature (NMOT: air mass AM 1.5, irradiance 800 W/m², temperature 68°F (20°C), windspeed 3.3 ft/s (1 m/s). * Where xxx indicates the nominal power class (PMAX) at STC above. GENERAL DATA Cell type: 120 half-cut cells with REC heterojunction cell technology 6 strings of 20 cells in series Glass:0.13 in (3.2 mm) solar glass with anti-reflection surface treatment Backsheet:Highly resistant polymeric construction (black) Frame:Anodized aluminum (black) Junction box:3-part, 3 bypass diodes, IP67 rated in accordance with IEC 62790 Connectors:Stäubli MC4 PV-KBT4/KST4, 12 AWG (4 mm²) in accordance with IEC 62852 IP68 only when connected Cable:12 AWG (4 mm²) PV wire, 39 + 47 in (1 + 1.2 m)in accordance with EN 50618 Dimensions:67.8 x 40 x 1.2 in (1721 x 1016 x 30 mm) 18.8 sq ft (1.75 m²) Weight:43 lbs (19.5 kg) Origin:Made in Singapore STC NMOTREC ALPHα BLACK SERIESPRODUCT DATASHEET REC Group is an international pioneering solar energy company dedicated to empowering consumers with clean, affordable solar power in order to facilitate global energy transitions. Committed to quality and innovation, REC offers photovoltaic modules with leading high quality, backed by an exceptional low warranty claims rate of less than 100ppm. Founded in Norway in 1996, REC employs 2,000 people and has an annual solar panel capacity of 1.8 GW. With over 10 GW installed worldwide, REC is empowering more than 16 million people with clean solar energy. REC Group is a Bluestar Elkem company with headquarters in Norway, operational headquarters in Singapore, and regional bases in North America, Europe, and Asia-Pacific. The high-powered smart grid-ready Enphase IQ 7 Micro™ and Enphase IQ 7+ Micro™ dramatically simplify the installation process while achieving the highest system efficiency. Part of the Enphase IQ System, the IQ 7 and IQ 7+ Microinverters integrate with the Enphase IQ Envoy™, Enphase IQ Battery™, and the Enphase Enlighten™ monitoring and analysis software. IQ Series Microinverters extend the reliability standards set forth by previous generations and undergo over a million hours of power-on testing, enabling Enphase to provide an industry-leading warranty of up to 25 years. Enphase IQ 7 and IQ 7+ Microinverters To learn more about Enphase offerings, visit enphase.com Data SheetEnphase MicroinvertersRegion: AMERICAS Easy to Install • Lightweight and simple • Faster installation with improved, lighter two-wire cabling • Built-in rapid shutdown compliant (NEC 2014 & 2017) Productive and Reliable • Optimized for high powered 60-cell and 72-cell* modules • More than a million hours of testing • Class II double-insulated enclosure • UL listed Smart Grid Ready • Complies with advanced grid support, voltage and frequency ride-through requirements • Remotely updates to respond to changing grid requirements • Configurable for varying grid profiles • Meets CA Rule 21 (UL 1741-SA) * The IQ 7+ Micro is required to support 72-cell modules. 1. No enforced DC/AC ratio. See the compatibility calculator at https://enphase.com/en-us/support/module-compatibility. 2. Nominal voltage range can be extended beyond nominal if required by the utility.3. Limits may vary. Refer to local requirements to define the number of microinverters per branch in your area. To learn more about Enphase offerings, visit enphase.com © 2018 Enphase Energy. All rights reserved. All trademarks or brands used are the property of Enphase Energy, Inc. 2018-05-24 INPUT DATA (DC) IQ7-60-2-US / IQ7-60-B-US IQ7PLUS-72-2-US / IQ7PLUS-72-B-US Commonly used module pairings¹235 W - 350 W +235 W - 440 W + Module compatibility 60-cell PV modules only 60-cell and 72-cell PV modules Maximum input DC voltage 48 V 60 V Peak power tracking voltage 27 V - 37 V 27 V - 45 V Operating range 16 V - 48 V 16 V - 60 V Min/Max start voltage 22 V / 48 V 22 V / 60 V Max DC short circuit current (module Isc)15 A 15 A Overvoltage class DC port II II DC port backfeed current 0 A 0 A PV array configuration 1 x 1 ungrounded array; No additional DC side protection required; AC side protection requires max 20A per branch circuit OUTPUT DATA (AC) IQ 7 Microinverter IQ 7+ Microinverter Peak output power 250 VA 295 VA Maximum continuous output power 240 VA 290 VA Nominal (L-L) voltage/range²240 V / 211-264 V 208 V / 183-229 V 240 V / 211-264 V 208 V / 183-229 V Maximum continuous output current 1.0 A (240 V)1.15 A (208 V)1.21 A (240 V)1.39 A (208 V) Nominal frequency 60 Hz 60 Hz Extended frequency range 47 - 68 Hz 47 - 68 Hz AC short circuit fault current over 3 cycles 5.8 Arms 5.8 Arms Maximum units per 20 A (L-L) branch circuit³16 (240 VAC)13 (208 VAC)13 (240 VAC)11 (208 VAC) Overvoltage class AC port III III AC port backfeed current 0 A 0 A Power factor setting 1.0 1.0 Power factor (adjustable)0.7 leading ... 0.7 lagging 0.7 leading ... 0.7 lagging EFFICIENCY @240 V @208 V @240 V @208 V Peak CEC efficiency 97.6 %97.6 %97.5 %97.3 % CEC weighted efficiency 97.0 %97.0 %97.0 %97.0 % MECHANICAL DATA Ambient temperature range -40ºC to +65ºC Relative humidity range 4% to 100% (condensing) Connector type (IQ7-60-2-US & IQ7PLUS-72-2-US)MC4 (or Amphenol H4 UTX with additional Q-DCC-5 adapter) Connector type (IQ7-60-B-US & IQ7PLUS-72-B-US)Friends PV2 (MC4 intermateable). Adaptors for modules with MC4 or UTX connectors:- PV2 to MC4: order ECA-S20-S22- PV2 to UTX: order ECA-S20-S25 Dimensions (WxHxD)212 mm x 175 mm x 30.2 mm (without bracket) Weight 1.08 kg (2.38 lbs) Cooling Natural convection - No fans Approved for wet locations Yes Pollution degree PD3 Enclosure Class II double-insulated, corrosion resistant polymeric enclosure Environmental category / UV exposure rating NEMA Type 6 / outdoor FEATURES Communication Power Line Communication (PLC) Monitoring Enlighten Manager and MyEnlighten monitoring options.Both options require installation of an Enphase IQ Envoy. Disconnecting means The AC and DC connectors have been evaluated and approved by UL for use as the load-break disconnect required by NEC 690. Compliance CA Rule 21 (UL 1741-SA)UL 62109-1, UL1741/IEEE1547, FCC Part 15 Class B, ICES-0003 Class B, CAN/CSA-C22.2 NO. 107.1-01 This product is UL Listed as PV Rapid Shut Down Equipment and conforms with NEC-2014 and NEC-2017 section 690.12 and C22.1-2015 Rule 64-218 Rapid Shutdown of PV Systems, for AC and DC conductors, when installed according manufacturer’s instructions. Enphase IQ 7 and IQ 7+ Microinverters