Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
19278 Impala Ave
CITY OF LAKEVILLE CERTIFICATION OF GRADING AND FINAL PLACEMENT OF IRON MONUMENTS Building Permit #: Legal Description: Lot 7 Block 4 Subdivision: SUMMERLYN 6TH ADDITION Address: 19278 Impala Avenue. Lakeville. Minnesota RECEIVED By Christina Orlowsky at 12:10 pm, Jul 29, 2020 We -F hereby certify that on 23rd day of July , 2020 an inspection of this property was conducted by me or under my direct supervision and that the as -built grades, elevations and drainage patterns of the site and building are in conformance with the grading plan approved by the City Engineer or amendments previously approved by the City Engineer. In addition, all property corner monuments are in place as of this date. Exceptions noted. I hereby certify that this survey, plan or report was prepared by me or under my direct supervision and that I am a duly Licensed Land Surveyor under the laws of the State of Minnesota. Print Name: �i9P .ter J! Hawkinson 9 Si nature: / i Date: July 27, 2020 MN License #: 42299 NOTE: ATTACH A COPY OF THE CERTIFICATE OF SURVEY SHOWING ALL AS - BUILT GRADES, ELEVATIONS AND DRAINAGE PATTERNS Approved subdivision grading plans should be obtained from the property owner or developer. General questions relating to the building permit should be directed to the Building Inspections Department at 952-985-4440. Questions relating to grading should be directed to the Engineering Department at 952-985-4500. Prior to release of the Grading Security, this document shall be filed with: City of Lakeville Engineering Department 20195 Holyoke Avenue Lakeville, MN 55044 11x17 30 1044.2 1044 3 1044 9 1044.5 1045.6 1044 5 x 1045.2 1044.9 X r1044.4 1044 3 N00°02%3E 30I < 0 / I ▪ ▪ 1043 3 M 1043.4 O x 1043.8 1045 4 1043 8 1045.6 t7 1044.3 _O 1044.3 44 3 1044. ❑ ■ f___11) 1Op4.7� / /c 1045 4 / 10460 x 1044 5 JO I 1046.2 1046.3 10463 1046.4 1046 7 10 .0 X ) 046 3 X 1037.2 IIIgg 104 !4 x .1045.7 10 •.1 Ji. � 110453 01 1044.21039.6 / 1044.2 I X`��■ 10451$44: •••� •'��17 1039.6X 1�378 10357 10 x 10441 10439 ■X •���`1041.6 1040.5�����������•: „k„_.... �Oe3... , X 1033.3 /X 1/AA327 1042 3 x 1037 71 X 1034 3_ -4S O _ 10301 9X X 1042 5 X 1038.7 1034 9 V - X 1032.8 • X 43 0 x Inv) o X 103E 6 1045 7 X 1044.6 X1044.0 S?2 °36'31., yo�'Se x 1043 5 X 1043 6 X 1037 8 x 1043.1` x 1043.1 X 1038.2 x 1044 5 1041 3 Xi 42 �1/•.... X 1038. 1046 5 \ X X 1039,0 1037 0 1045.6 �' 1043 8 x 1041 3 X 1038.1 X 1037.8 Sodded X 1036 4 1035.6 X 1040.9 X 1036.7 1038 4 1038 1 X 1038 1 X 1037 9 X 1037 6 7 X 1042 2 Construction Notes: 1. Install rock construction entrance. 2 Install silt fence as needed for erosion control. 3. Sidewalks shall drain away from house a minimum of 1.0%. 4 Contractor must verify driveway design 5. Contractor must verify service elevation prior to construction. 6 Add or remove foundation ledge as required. X 1040 8 Sodded X 1038 9 General Notes: 1. Grading plan by Pioneer Engineering last dated 01/26/17 was used to determine proposed elevations shown herein. 2. This survey does not purport to show improvements or encroachments, except as shown, as surveyed by me or under my direct supervision. 3. Proposed building dimensions shown are for horizontal location of structures on the lot only. Contact builder prior to construction for approved construction plans 4. No specific soils investigation has been performed on this lot by the surveyor The suitability of soils to support the specific house proposed is not the responsibility of the surveyor. 5. This certificate does not purport to show easements other than those shown on the recorded plat. 6. Bearings shown are based on an assumed datum. X 1036 9 X 1036 3 N89°53'33"W ^I If, Af, Ar-DI \it\ I .;IJIVIIVIL_I \L_ I IN CO < 1038 8 x 1038.2 X 1034 8 X 1037.7 X 1032 7 • Denotes iron pipe 4•63 • X 000 00 ( 000 00 ) 1031 9 X 1032.1 120.04 TI I 1 r1 Denotes service Denotes television box Denotes electric box Denotes telephone box Denotes existing elevation Denotes proposed elevation Denotes drainage flow direction Denotes spike Denotes conservation post Denotes proposed retaining wall designed and built by others. , 129.25 X 1034 9 X 1034.0 x 1031 9X 1029 6 CO 1029 8 0 X 1028 4 ` x 1033. • 031 7 1029.1 X 1034.8 /J JO X 1036.5 X2 /X1031 10334 / / X 1035.4 / ••-. 43 /10 a ` aC � / X/ 6) 1034.8 / C F o rn a 1029.5 X 1028.4 1030 10288 x 1028 3 X 1029.6 1031 6 X 1030.3 (1032.2) X 1029 4^ 1030.8 1029 8 X 1032 0 X 10321 Graded X 1031 9 A r\r11Tlr\N I /-\LJLJI I I Lot area = 9533 sf House area = 1950 sf Porch area = 151 sf Sidewalk area = 41 sf Driveway area = 702 sf Total Impervious Area = 2844 sf Impervious Coverage = 29.8 % / REVISED 7/23/20 GRADING AS -BUILT Lowest opening elevation per grading plan :1038.5 Lowest floor elevation per grading plan : 1038.5 House elevations Lowest Floor Elevation Top Of Foundation Elev. Garage Slab Elev. (Proposed) / As -built : (1038.8) / 1038.8 :(1046.8) / 1046.7 © Door :(1046.5) / 1046.5 We hereby certify to Lennar Corporation that this survey, plan or report was prepared by me or under my direct supervision, and that I am a duly licensed Land Surveyor under the laws of the State of Minnesota, dated 07/22/19. BY Signed: iArleer Engineering, P.A. Peter J. HaLl ( ibn, trrotegonal Land surveyor Minnesota License No 42299 email-phawkinson@pioneereng.com 0' i 10' i 20' Scale: 1" = 20' Benchmark: Top Nut Hydrant Lot 10 Block 3 Elevation = 1046.12 Revisions 1 ) 07-24-19 Stake house 2) 07-29-19 Add wall 3 ) 07-23-20 Grading As -built • 2 o• soa •• 3 X3 w3 9 to 0 2 3 rn rn rn at •o 0 rn ▪ t9 N 0 o 10 N a W • � It 4. o 1r