19307 Impala Ave
CITY OF LAKEVILLE CERTIFICATION OF GRADING AND FINAL PLACEMENT OF IRON MONUMENTS Building Permit #: 169438 Legal Description: Lot 12 Block 1 RECEIVED By KHolloway at 8:46 am, Jun 02, 2020 Subdivision: SUMMERLYN 4TH ADDITION Address: 19307 Impala Aveneue We -F hereby certify that on 22nd day of Mav 2020 an inspection of this property was conducted by me or under my direct supervision and that the as -built grades, elevations and drainage patterns of the site and building are in conformance with the grading plan approved by the City Engineer or amendments previously approved by the City Engineer. In addition, all property corner monuments are in place as of this date. Exceptions noted. I hereby certify that this survey, plan or report was prepared by me or under my direct supervision and that I am a duly Licensed Land Surveyor under the laws of the State of Minnesota. Print Name: (/P .ter 1/ Hawkinson Signature: .( / Date: May 22, 20 MN License #: 42299 NOTE: ATTACH A COPY OF THE CERTIFICATE OF SURVEY SHOWING ALL AS - BUILT GRADES, ELEVATIONS AND DRAINAGE PATTERNS Approved subdivision grading plans should be obtained from the property owner or developer. General questions relating to the building permit should be directed to the Building Inspections Department at 952-985-4440. Questions relating to grading should be directed to the Engineering Department at 952-985-4500. Prior to release of the Grading Security, this document shall be filed with: City of Lakeville Engineering Department 20195 Holyoke Avenue Lakeville, MN 55044 11x17 A r X 1039 4 N N ▪ X 1037.7 X ° 1037 6 0 0 1037.3 X 10383 ) 0 x 1038 5 1037.7 • 1038.1 X 1038.3 r 1037.7 0 x1038,3( �-, 10 >`-�-. a 1037 x a 1038.0 0 .,., N N o E c o O X 1040 2 x 10313.9 S89°57'57"E X 1041.1 10395 Sodded X 1042 1 X 104p„3._ x11038.2 X 1039 3 1038.4 X 1037.9 1037 9 1037.2 /1 x 10// x1037 7 I x1038.9 X 1039 1 X 1039.0 X 1039.1 X 1039.6 1039.7 63.0‹ X 1039.6 12 x X 1038 6 1038.4 x 1040.2 x 1039.9 X 1039 8 X 1039.8 1041.1 1040 4 1040.3 1�4p_p- 1041.5 1040.4104o, / 21.4 X 1040.1 X 1040.2 X 1040 4 pp 104. X10402 10403; X1039.3 X 10399 10405 X 10431 X 1043 3 X 1040.7 136.07 House X 1042 4 X 1041 6 It OI 1T1-0472 O• II J 1044.1 X 1042.2 F t 34.1 x 1042 8 O 1044 x 1044.4 i uv.s?51 X 1044.0 x 1043 9 X 1043� -" 1u43.4 X 1044.4 x 1044.1 X 104 1045 2 1045.0 4 1 X 1044.4 toy J, 26.5 / ��„125.5�--1oa 1044. 1 043.9 • 4 1043.E njn .e 1042.3 301 O f04?t 810421.3 ❑ v • 1104 $0 10d2.7 �II 1042.9 ` 10A2 8 • 104211 x \. 1 1 6043 1042.3 ' I IU 4 1042.4 I 104 .7 1 1042.8 , 0 1044.6 1044.6 1044.1 045.1 1043 81 1045 0 1044 9 X 1045.7 1044 5 - 1044.5 1045 2 1044.8 / L_ /1036.0 X 1037.2 / 1036 2" i X 1037.3 X 1038 0 t0 X 1038.4 x 1036 5 In 1037 6 1035! 0 x 1036 8 to X 1036.7 Lot area =9562 SF House area =1857 SF Porch area =160 SF Sidewalk area =31 SF Driveway area =694 SF Total Impervious Area =2742 SF Impervious Coverage =28.7% X 1038 5 S89°57'57"E 9 1039.0 X 1039.6 Denotes proposed retaining wall designed and built by others • Denotes iron pipe Denotes service ® Denotes television box ▪ Denotes electric box ❑� Denotes telephone box 000.00 Denotes existing elevation 000.00 ) Denotes proposed elevation Denotes drainage flow direction • Denotes spike Construction Notes 1. Install rock construction entrance. 2 Install silt fence as needed for erosion control 3. Sidewalks shall drain away from house a minimum of 1.0%. 4 Contractor must verify driveway design. 5. Contractor must verify service elevation prior to construction. 6 Add or remove foundation ledge as required General Notes: 1. Grading plan by Pioneer Engineering last dated 2/25/15 was used to determine proposed elevations shown herein. 2. This survey does not purport to show improvements or encroachments, except as shown, as surveyed by me or under my direct supervision. 3. Proposed building dimensions shown are for horizontal location of structures on the lot only. Contact builder prior to construction for approved construction plans. 4 No specific soils investigation has been performed on this lot by the surveyor. The suitability of soils to support the specific house proposed is not the responsibility of the surveyor. 5. This certificate does not purport to show easements other than those shown on the recorded plat. 6. Bearings shown are based on an assumed datum. PItNEERneering, P.A, CIVn. ENGINEERS LAND PLANNERS LAND SURVEYORS LANDSCAPE ARCHITECTS 2422 Enterprise Dnve Ph. : (651) 681-1914 Mendota Heights, MN 55120 Fax: (651) 681-9488 www.ptoneereng com Project # .115225034 (Folder #: 7746'Drawn by MTW $ © Pioneer Engineering X 1042.2 X 10421 1042 8 House -67T- 1043 6 X X 1043.1*-Tc- X 1043. 1044 X tob 137.13 1043 1 10437 O X 1043 3 1043.0 1041 8 1042 7 1042 4 r) I x 1043 2 1041x7�p Sodded n • 1042 4 1042.f . 4 • .,4 v • • Lowest floor elevation per grading plan : 1037.7 House elevations Lowest Floor Elevation Top Of Foundation Elev. (Proposed) / As -built :(1037.8) / :(1045.8) / 1045.9 Garage Slab Elev. © Door :*(1044.8)* / T.O.F. Elevation © Lookout:(1041.0) / 1041.1 REVISED 05/22/20 GRADING AS -BUILT We hereby certify to Lennar Corporation that this survey, plan or report was prepared by me or under my direct supervision, and that I am a duly licensed Land Surveyor under the laws of the State of Minnesota, dated 04/12/19. Signed: BY: _ w resssrial Land Surveyor Minnesota License No. 42299 email-phawkinson@pioneereng.com eer Engineering, P A Lot 12, Block 1, SUMMERLYN 4TH ADDITION according to the recorded plat thereof Dakota County, Minnesota Address: 19307 Impala Avenue, Lakeville, Minnesota House Model: Sinclair 4007 Elevation: K3 Buyer: Spec v v 0 0 d 0' 10' 20' 111 Scale. 1" = 20' Benchmark Top Nut Hydrant Lots 15-16 Block 1 Elevation = 1033.27 Revisions 1) 04-15-19 Stake house 2) 05-13-19 Add retammg wall 3) 08-07-19 Re -stake house 4 ) 05-22-20 Grading As -built Certificate of Survey for: Lennar Corporation 16305 36th Ave N Ste #600 Plymouth, MN 55446-4270 Phone: (952) 249-3000 / Fax: (952) 404-1909 tr