Loading...
HomeMy WebLinkAbout19763 Henning Ave Survey(1053.1)XGARAGEPROPOSEDHOUSETNH1060.13FD IPOS 38.09 HUB=1057.40OS 48.51 HUB=1052.46 FD IPFD IPOS 31.66 HUB=1052.51 OS 36.41 HUB=1055.67C.O.C.O.FD IPSERVR:1055.90R:1057.32R:1057.88PORCHPORCHEXISTINGHOUSEHENNING AVENUE105 55510 10 10 S00°14'50"W 130.00 S89°56'24"W 95.00N89°56'24"E 95.00N00°14'50"E 130.00 5.92 21.50 33.83 16.83 3.00 14.83 3.17 10.00 17.33 11.17 24.50 11.00 2.00 20.50 14.17 9.67 4.00 11.6730.36 14.8927.1052.64DRAINAGE &UTILITY EASEMENT1056.91056.91056.21055.91055.41055.41062.31053.81059.7 1060.0 1057.31056.41048.61054.51055.91055.71054.11052.51052.41052.31052.5(1058.10)(1057.5)(1056.0)(1054.5)(1048.6)(1057.7)(1057.4)(1052.5) (1052.5)(1057.1)FUTURE SIDEWALK(1056.8)1057.9 LOOKOUT(1057.7)VACANT LOT 4.1%(1053.1)1052.01050.01051.9 (1051.6)DENOTES EXISTING CATCH BASINDENOTES EXISTING HYDRANTDENOTES EXISTING SANITARY MANHOLEDENOTES EXISTING STORM MANHOLEDENOTES EXISTING UTILITY BOXDENOTES EXISTING SERVICE OR CLEANOUTDENOTES IRON MONUMENT FOUNDDENOTES IRON MONUMENT SETDENOTES EXISTING POWER POLEDENOTES EXISTING LIGHT POLEDENOTES EXISTING CONSERVATION POSTOR WET LAND BUFFER POSTDENOTES EXISTING TREE8" TREE000.0DENOTES WOOD HUBDENOTES NAILDENOTES EXISTING RETAINING WALLDENOTES PROPOSED RETAINING WALLDENOTES EXISTING ELEVATIONDENOTES PROPOSED ELEVATIONDENOTES AS BUILT ELEVATION(000.0)000.0DENOTES EXISTING TREELINEDENOTES DIRECTION OF SURFACE DRAINAGEDENOTES EXISTING FENCELEGENDDENOTES EXISTING F.E.S.LOT AREA : 12,350 SQ. FT.HOUSE AREA : 1,894 SQ. FT.PORCH AREA : 166 SQ. FT.DRIVEWAY AREA : 851 SQ. FT.SIDEWALK AREA : 44 SQ. FT.BUILDING COVERAGE AREA : 2060 SQ. FT. (16.7%)CERTIFICATE OF SURVEYLegal Description:= FINISHED GARAGE FLOOR ELEVATION= BASEMENT FLOOR ELEVATION= TOP OF FOUNDATION ELEVATION(1058.10)(1058.43)(1050.43)1. No specific soils investigation has been performed on this lotby the surveyor. The suitability of the soils to support thespecific house is not the responsibility of the surveyor.2.No title information was provided for this survey. This surveydoes not purport to show all easements of record.3. See architectural plans for final building dimensions.NOTES 1. 1050.1 LOW FLOOR 2. ROCK CONSTRUCTION ENTRANCE AT DRIVEWAY. 3. SILT FENCE AT GRADING LIMITS. 4. DRIVEWAY WIDTH AT RIGHT-OF-WAY IS 24' WITHOUT PERMITREVISED 05-18-2021: REMOVE SIDE LOOKOUTS AND RETAINING WALL.Zoning = RS-3FY - 30'SY - 10' Interior, 20' CornerRY - 30'SY Buffer - 30'RY Buffer - 50'*Draintile connection required.ENGINEERING REVIEWEDDate:__________________05/24/2021jpesikThe curb box, drain tile cleanout, and catchbasin(if applicable) must be inspected andaccepted before As-Built escrow monies willbe released. All structures must be flushwith the sod. This will be scheduled with thelandscape inspection.EROSION CONTROL MUST BE INSTALLED BEFORE EXCAVATION*Maintain 6" between bottom of siding and sod.*No structures in easements.