Loading...
HomeMy WebLinkAboutLA191642 - 17858 Hamburg Ave Permit PackRESIDENTIAL BUILDING PERMIT APPLICATION CITY OF LAKEVILLE BUILDING INSPECTIONS DEPARTMENT 20195 HOLYOKE AVENUE LAKEVILLE, MN 55044 952-985-4440 Office Use Only __________________ Permit Number ___________________ Received By ___________________ Date Received ___________________ Fee Total SITE ADDRESS: MAILING ADDRESS: CITY: STATE: ZIP: JOB DESCRIPTION:__________________________________ MASTER PLAN: (Number or Address)____________________ LIST OTHER STRUCTURES ON PROPERTY:_______________________________________________________________ ESTIMATED VALUATION: PROPOSED START DATE: END DATE: (New Residential Only): LEGAL DESCRIPTION: LOT: _____ BLOCK: _____ SUBDIVISION: APPLICANT IS: RESIDENT OWNER CONTRACTOR EMAIL NEW MODEL HOME: YES NO (IF YES – ADMINISTRATIVE PERMIT REQUIRED) PLEASE FILL OUT THE FOLLOWING COMPLETELY (All Contractor information must be as listed on State License) RESIDENT OWNER NAME:_______________________________________________________________________________ HOME PHONE #:_____________________________ CELL PHONE:___________________________ GENERAL CONTRACTOR Homeowner Contractor CONTRACTOR:_______________________________________________________________________ LICENSE #:BC______________ LEAD CERTIFICATE#_______________ (PRE 1978 STRUCTURE) OFFICE PHONE #:_____________________________ CELL PHONE:___________________________ ADDRESS:____________________________ CITY:________________ ST:______ ZIP:____________ PLUMBING WORK Homeowner Contractor CONTRACTOR:__________________________________________LICENSE #: PM______________ OFFICE PHONE #:_____________________________ CELL PHONE:___________________________ ADDRESS:____________________________ CITY:________________ ST:______ ZIP:____________ MECHANICAL WORK Homeowner Contractor CONTRACTOR:________________________________________ _______________________________ OFFICE PHONE #:_____________________________ CELL PHONE:___________________________ ADDRESS:____________________________ CITY:________________ ST:______ ZIP:____________ BOND #:_______________________________________ EXPIRATION DATE____________________ SEWER/WATER CONTRACTOR New Construction Only NAME:________________________________________________ ______________________________ HOME PHONE _____________________________ CELL PHONE:______________________________ BOND #:_______________________________________ EXPIRATION DATE____________________ INTEREST EARNINGS ON THE ESCROW ACCOUNTS, IF ANY, ARE RETAINED BY THE CITY TO OFFSET THE ADMINISTRATIVE COSTS ASSOCIATED WITH PROCESSING THE ESCROW APPLICATION AND REFUND. I HEREBY APPLY FOR A BUILDING PERMIT AND I ACKNOWLEDGE THAT THE INFORMATION ABOVE IS COMPLETE AND ACCURATE; THAT THE WORK WILL BE IN CONFORMANCE WITH THE ORDINANCES AND CODES OF THE CITY AND WITH THE STATE BUILDING CODE, THAT I UNDERSTAND THIS IS NOT A PERMIT AND WORK IS NOT TO START WITHOUT A PERMIT AND THAT THE WORK WILL BE IN ACCORDANCE WITH THE APPROVED PLAN. NAME OF APPLICANT (Please Print)DATE APPLICANT’S SIGNATURE: www.lakevillemn.gov Nick Reimler RESIDENTIAL BUILDING PERMIT APPLICATION PAGE 2 OFFICE USE ONLY BUILDING PERMIT TYPE REQUIRED INSPECTIONS SINGLE FAMILY DWELLING BUILDING DUPLEX AS BUILT TOWNHOUSE UNITS BUILDING FINAL DETACHED TOWN HOUSE UNIT DECK FOOTING CONDO FIREPLACE ACESSORY BUILDING FOOTING REROOF FOUNDATION RESIDE FRAMING PORCH FRAMING GARAGES INSULATION RES ADDN/REPAIR/RMDL DECK PORCH GARAGES LATH LOWER LEVEL FINISH LOWER LEVEL FINAL ADDITION OTHER FOUNDATION ONLY PORCH FOOTING MISCELLANEOUS POURED WALL DEMO SEPTIC TANK REMOVAL MOVED SITE MECHANICAL CITY BUILDING VALUATION: $AIR TEST FINAL BUILDING PERMIT FEES ROUGH-IN $PERMIT FEE PLUMBING $PLAN CHECK FINAL $SURCHARGE ROUGH-IN $METRO SAC METER SIZE $CITY WATER HOOKUP UNIT PRESSURE REDUCING VALVE $CITY SEWER HOOKUP UNIT SEWER/WATER $LANDSCAPE ESCROW SEWER/WATER $TREE ESCROW FINAL $MISC ESCROW STREET DRAINTILE $PLUMBING BUILDING INFORMATION $MECHANICAL TYPE OF CONSTRUCTION $SEWER WATER ZONING $OTHER CODE EDITION $TOTAL FIRE SUPPRESSION SYSTEM OCCUPANCY GROUP APPROVED BY: BUILDING INSPECTOR: Date: PLUMBING/MECHANICAL INSPECTOR: Date: COMMENTS: 20195 Holyoke Avenue, Lakeville, MN 55044 952-985-4400  952-985-4499 fax www.lakevillemn.gov Sewer & Water Tie Card Address:________________________________________ Contractor:______________________________________ Permit Number:__________________________________ Final Date:________________ Street Drain-Tile:______ Size of Water Service: 1” Comments: AIRTEST SANITARY OVER 20’/2 FITTINGS THIS CARD MUST BE COMPLETED AND ON-SITE AT TIME OF SEWER & WATER INSPECTION 19GENERAL NOTES:1. ALL DOOR AND WINDOW HEADERS TO BE S.P.F. #2 OR BETTER, SEE PLANS FOR SIZES.2. HOUSE TO BE BUILT PER CURRENT I.R.C. CODES.3. VERIFY GRADES AND ADJUST FOUNDATION/FOOTING STEPS AS NEEDED.4. SEE PLANS FOR CEILING HEIGHTS5. 4' HIGH POURED FDN. WALLS STD.6. FLOOR PLAN DIMENSIONS ARE TO FACE OF FRAMING AND FOUNDATION.7. ALL TRADES & SUPPLIERS TO REVIEW & VERIFY INFORMATION PERTINENT TO THEIR WORK AND NOTIFY CONST. OF ANYDISCREPANCIES PRIOR TO CONSTRUCTION.8. NOTED CABINET SIZES ARE +/- AND TO BE FIELD VERIFIED.9. TRADES TO VERIFY BASE AND TRIM SIZE PRIOR TO CONSTRUCTION.10. ALL WALLS MORE THAN 10' H. TO BE S.P.F. #2 OR BETTER. 11. EXTERIOR ELEVATIONS ARE CONCEPTUAL ONLY:HOME SITE, FILL AND TOPOGRAPHY WILL DICTATEACTUAL GRADES AND MAY VARY FROM THOSE SHOWN ON THE PLAN.12. NOTE: SUBFLOOR JOINTS SHALL BESTAGGERED FROM FLOOR TRUSS ORJOIST JOINTSOFSHEET07-00-BUYERPROJECT #BUYER S/OBUYER S/OREVISIONS:STARTED:AGENT:XXLOT 3, BLOCK 10 SUMMER'S CREEK 17858 HAMBURG DR. LAKEVILLE, MN "NANTUCKET" 1650 VILLA HOME MARK ELLIOTT HOMES1-7-2021 PERMIT1-7-2021 REDLINES5-24-21 GARAGE6-1-21 CALCSREAR ELEVATIONSCALE: 3/16" = 1'-0"FRONT ELEVATIONSCALE: 1/4" = 1'-0"SEE ROOF PLAN FORROOF PITCHES ANDOVERHANGS25'-6"CONC. PORCH4" TRIM TYP.6:12ALUM. SOFFIT& FASCIA30 YR. ARCH. ASPHALT SHINGLES 6" TRIM9'-1 1/8"T.O. SUBFLR.T.O. PLATE 1'-8 1/4"T.O. FDN.9'-1 1/8"@ GARAGET.O. PLATE 121212122'-6"T.O. (2) 3054 SH (BLACKENED)12" CANT.10" TRIMC/LLP SMARTSIDEBOARD & BATTENT.O. FDN.10'-4"FP CHASE24"x60" FALSELP PANEL14" LP COLUMN 14" LP COLUMN 14" LP COLUMN 6'-9" 1'-6"@ GARAGE12" SHINGLED EYEBROW10" LP WRAP HEADER2x OVER 6" TRIM2x OVER 6" TRIMSTONE TOTAL: 88 SQ. FT. (31.3%)TOTAL SQ. FT.: 269 SQ. FT.MATERIAL CALCULATIONS: FRONT ELEV.LP LAP SIDING TOTAL: 30 SQ. FT. (10.7%)LP B&B TOTAL: 129.3 SQ. FT. (46.0%)LP PANEL: 34 SQ. FT. (12.1%)STONE TOTAL: 142 SQ. FT. (9.8%)TOTAL SQ. FT.: 1,900MATERIAL CALCULATIONS: ALL ELEV.LP LAP SIDING TOTAL: 1112 SQ. FT. (76.4%)LP B&B TOTAL: 168 SQ. FT. (11.6%)LP PANEL: 34 SQ. FT. (2.3%)WFPT.O. PLATE9'-1 1/8"T.O. SUBFLR.T.O. FDN.1'-8 1/4"12" CANT.WFPWFPWFPSEE ROOF PLANFOR PITCHES ANDOVERHANGSALUM. SOFFIT& FASCIA6:12LP SIDING PER SPECSMETAL CORNERS4" VINYL TRIM @ WDWS. & DOORS TYP.10" TRIMConcept Approval ONLYSubject to Field InspectionInspectorDate2020MN BldgCode06/01/2021dmathews EXTERIOR ELEVATIONS ARE CONCEPTUAL ONLY: HOME SITE, FILL AND TOPOGRAPHY WILL DICTATE ACTUAL GRADES AND MAY VARY FROM THOSE SHOWN ON THE PLAN.2 9 07-00-BUYERPROJECT # BUYER S/O BUYER S/O REVISIONS: STARTED: AGENT:X XLOT 3, BLOCK 10 SUMMER'S CREEK17858 HAMBURG DR. LAKEVILLE, MN"NANTUCKET" 1650 VILLA HOMEMARK ELLIOTT HOMES1-7-2021 PERMIT 1-7-2021 REDLINES 5-24-21 GARAGE 6-1-21 CALCS OF SHEET SIDE ELEVATION SIDE ELEVATION SCALE: 3/16" = 1'-0" SCALE: 3/16" = 1'-0" ALUM. SOFFIT & FASCIA 12 6 T.O. PLATE 9'-1 1/8"T.O. SUBFLR. T.O. FDN.1'-8 1/4"12 6 10" TRIM 12" CANT. FP VENT SEE ROOF PLAN FOR PITCHES AND OVERHANGS 12:12 14" LP COLUMNLP SIDING PER SPECS LP CORNERS 4" LP TRIM @ WDWS. & DOORS TYP. @ GARAGE 9'-1 1/8"T.O. FDN.A/C UNIT T.O. PLATE 9'-1 1/8"T.O. SUBFLR. T.O. FDN.1'-8 1/4"10" TRIM LP CORNERS 4" LP TRIM @ WDWS. & DOORS TYP. 12 6 12 6 LP SIDING PER SPECS T.O. PLATE SEE ROOF PLAN FOR PITCHES AND OVERHANGS 8" TRIM 12:12 12:12 SCALE: 3/16" = 1'-0" FOUNDATION PLAN 3 9 07-00-BUYERPROJECT # BUYER S/O BUYER S/O REVISIONS: STARTED: AGENT:X XLOT 3, BLOCK 10 SUMMER'S CREEK17858 HAMBURG DR. LAKEVILLE, MN"NANTUCKET" 1650 VILLA HOMEMARK ELLIOTT HOMES1-7-2021 PERMIT 1-7-2021 REDLINES 5-24-21 GARAGE 6-1-21 CALCS OF SHEET A/C UNIT w/ BRACKET FURN F.D. WH MECH. / STORAGE WS FUT. 3068F U T . 2 6 6 8 FUT. BDRM. #5 FUT. FAMILY ROOM R.I. BATH FUT. 36" V. CONC. H.B. H.B. 2" LEDGE TYP. TO PROVIDE ADD'L. SUPPORT FOR FILL FOR SLAB TYP. FND @ HOUSE / GARAGE 10" POURED CONC. W/ 4" LEDGE INSIDE 20X8 CONC. FTG. 2" FOAM SUMP H20 4" LEDGE TYP. FND @ STOOP 10" POURED CONC. W/ 4" LEDGE INSIDE 20X8 CONC. FTG. UNEXCAVATED 2" NOTE: NO DRYWALL @ CLG. REQUIRED IN THIS AREA - FIRE BLOCK @ PERIMETEROF OPNG. (80 SQ. FT. MAX.) 6"2" RADON VENT TO TERMINATE IN SUMP BASKET GARAGE/HOUSE COMMON WALL SEE FIRST FLOOR FOR GARAGE DOOR SIZE FOR M.O. NOTE: 4" LEDGE 2"CONC. CONC. 3 1/2'' CONC. FLOOR TYP. FND @ HOUSE 8" POURED CONC. (9' H.) 20X8 FTG REBAR PER CODE TYP. FND @ BRG. WALL 2x4 STUDS 16" O.C. 16X8 FTG REBAR PER CODE 4" CONC. CURB KITCHEN ISLAND ABV. FLR. TRUSS CO. FUT. 2 468 OPT. 2-2x10 (DR) 5/0 BI-PASS (9'-0"x11'-10") (25'-62"x12'-6") RADON VENT NOTE: EXTERIOR HOUSE AND GARAGE/HOUSE COMMON FDN. WALLS TO BE HELD 2'' IN. DIMENSIONS SHOWN ARE TO FACE OF 2'' EXTERIOR RIGID INSULATION & FRAMING ABOVE TO BE 5000 PSI CONC. NOTE: ALL FOOTINGS 2'' MIN. 2x8 TREATED SILL-OVERHANG FDN. 1 1/2''8"2" TYP. SIDE WALL DETAIL FOUND. HELD IN 2" FOR INSULATION NOTE: (TYP.) 8'-4" POURED FDN. APPROX. 1,634 NET SQ. FT. FILL FOR SLAB UP 17 R (10" T., 7-3/4" MAX. R.)56'-0"6'-0"50'-0"56'-0"33'-0"19'-4"13'-8"8'-0"14'-6"2'-6"40'-0" 19'-6" 13'-0"6'-0" & HOUSE/PORCH 18" FLR. TRUSSES19.2" O.C. SPACING3-9 1/2" LSL (DR) FOUND. HELD IN 2" FOR INSULATION NOTE: (TYP.) FUT. 206832x60FUT.TUB / SH SMOKECM / 12" CANT. ABV.2x6 BRG.2x6 BRG.18" FLR. TRUSSES19.2" O.C. SPACING9'-4"' H. FOUND. WALL @ FRONT OF HOME NOTE: 9'-4" H. FOUND. WALL@ FRONT OF HOME NOTE: w/ TOP HUNG TRUSSES w/ TOP HUNG TRUSSES 9'-4" H. FOUND. WALL @ FRONT OF HOME NOTE: w/ TOP HUNG TRUSSES 11'-1 1/2"3'-2 1/2"9'-9 3/4"15'-10 1/4" 11'-8 3/4"3'-2"1'-3"3'-0"7'-10"13'-0 1/4"3'-9"3'-10"7'-1 1/2"21'-3"11'-6"17'-3"9'-1 1/2"10'-4" 30"x30" CONC.PAD FTG. 6x6 COL. 2-2x10 (DR) 2-2x10 (FL) (2) TR 3-9 1/2" LSL (DR)5'-5"2'-11"2'-9" 2" FOAM 8"18" FLR. TRUSSES19.2" O.C. SPACINGREBAR PER CODE 2" RIGID INSUL. (INSIDE) CONC. FOUND. WALLS 2x6 STUDS @ 16" O.C. ON 20"x8" CONT. CONC. FTGS. 4'-0" H. x 8" W. POURED EXTERIOR WALK-OUT WALLS 1 TRTD. PLATE ON2"2"2"2" 40'-0" 8'-10"11'-6"12'-11"6'-9" 2'-4"22'-6"6"4" 10" 2x8 TREATED SILL OVERHANG FDN. 2'' GARAGE SLAB 2'' RIGID INSUL. MAIN FLR 6"21'-0" 6'x6'-8" PATIO DR.4060 SH @ 7'3660 SH @ 7'4860 PICT. @ 7'3660 SH @ 7' 2-9 1/2" LSL 2-9 1/2" LSL 2-9 1/2" LSL (CONT.) 4 1/2"4 1/2" Interior BWP Above UFER Ground -Provide 20' Rebar in footing and stub up near electrical service panel. SCALE: 3/16" = 1'-0" MAIN FLOOR PLAN 4 9 07-00-BUYERPROJECT # BUYER S/O BUYER S/O REVISIONS: STARTED: AGENT:X XLOT 3, BLOCK 10 SUMMER'S CREEK17858 HAMBURG DR. LAKEVILLE, MN"NANTUCKET" 1650 VILLA HOMEMARK ELLIOTT HOMES1-7-2021 PERMIT 1-7-2021 REDLINES 5-24-21 GARAGE 6-1-21 CALCS OF SHEETP.H.TBTR DW GAS RANGEMICRO ABV. FLUSH OH. LNDRY. DRYERWASHER 9' CLG. / LVP WIRE SH. 29 (OPT. UPPERS) 39 (VENT TO OUTSIDE) NOTE: - STD. BASE & CASING TO BE PRINCETON - 1/2 WALL w/ WD. CAP & INVERTED CASING NOTE: 2X6 EXT. WALLS U.N.O. 2X4 INT. WALLS U.N.O. - 42" UPPER CABINETS DOOR ROUGH OPENINGS: 83" HEIGHT 82" OVER VINYL CERAMIC TILE & WOOD 82" OVER CARPET SRO = SHEET ROCKED OPNG BIFOLD DOORS: PREHUNG UNITS: 2" WIDER THAN DOOR (EXAMPLE: 2668 ) 1 3/8" WIDER THAN DOOR FINISH SIZE NOTED ON PLAN CO = CASED OPENING ( WOOD ) (EXAMPLE: 2668 ) FINISH SIZE NOTED ON PLAN RO. 1 1/2" WIDER, 83" HIGH R.O. 1" WIDER, 83" HIGH PER SPECS DRIVEWAY NOTE: REF. 49 KITCHEN 9' CLG. / LVP 12'-3" x 12'-6" (155 SQ. FT.) 59 BUILT-INS79 LVL GREAT ROOM 9' CLG. / LVP FLR.36" GAS F.P.12'-8" x 13'-0" (167 SQ. FT.) / LVP 42" W. CONC. SIDEWALK OPT.FIBRGLS. 60x36 SHWR. UNIT 5'-0"210682-9 1/2" LSL2x6 FOYER 9' CLG. / LVP 6'-11" x 7'-1" (51 SQ. FT.) PORCH CONCRETE O. BATH 9' CLG. / VIN. 2x6 WALLS U.N.O. 4" SLOPED CONC. GARAGE CEIL. TO BE 5/8" TYPE 'X'GYP. BD. WALLS TO BE 1/2" GYP.SHEATHING. ALL WALLS & CEILINGS TOHAVE ONE COAT FIRETAPE GARAGE SLOPE CONC.6'x8' PATIO DR. 16'x7' O.H.D. R.O. 16'-1" FRAMING O. CLST 8' CLG. / CARPET36" VAN. BATH 2 BEDROOM #2 2 6 6 8 3648 SH @ 8'9' CLG. / CARPET 9' CLG. / VIN. 1/2 WALL w/ WD. CAP MANUF. TRUSSES24 O.C.OPT. BUFFET CABS.(12'-0"x12'-0") EXTERIOR FLOOR PLAN DIMENSIONS ARE TO OUTSIDE OF SHEATHING, INTERIOR DIMENSIONS ARE TO FRAMING. NOTE: ALL DRS/ WIN.'S REQUIRE 4" ON SIDES FOR CASING NOTE: 2X6 EXT. WALLS U.N.O. 2X4 INT. WALLS U.N.O. HEADER SPANS: UP TO 4'-11'' = 1 TRIMMER 5'-0'' AND BIGGER = 2 TRIMMERS UNLESS NOTED OTHERWISE INDICATES LOCATION OF SOLID BRG.32x60FGLS.TUB / SH (134 SQ. FT.) OWNERS BDRM. 9' CLG. / CARPET (12'-6"x13'-0") (164 SQ. FT.) SMOKECM / SD 2 - 4072 SH @ 8' UP 17 R (10" T., 7-3/4" MAX. R.) 2x6 8/0 H. SOFFIT MANUF. TRUSSES 24 O.C.ATTICACCESSAPPROX. 465 SQ. FT. MUDRM. 9' CLG. / LVP BENCH / APPROX. 9'-0'' CLG. @ MAIN LEVEL APPROX. 1,634 SQ. FT. HOOKS3068 MTL.3080 MTL.R&SH2668R&SH24682668 2068 R&SH R&SHLINEN SH. 9' CLG. / CARPET 9' CLG. 8' SOFFIT2 8 6 8 8' SOFFIT (5) SH. (5) SH. 9' CLG. / LVP 2 6 6 8R&SHR&SH36" VAN. LIN.CAB. 30683068 PKT.FLDG. C'TOP.(OPEN UNDER)2 - 4072 SH @ 8'60" VAN. DINING 9' CLG. / LVP FLR.10'-0" x 9'-0" (90 SQ. FT.) 3672 SH @ 8'3672 SH @ 8'4872 PICT. @ 8'MANUF. TRUSSES24 O.C.40'-0" 8'-10"11'-6"12'-11"6'-9"56'-0"6'-0"50'-0"5'-0 1/2"5'-5 1/2"12'-8 3/4"7"3'-11"5'-2 1/2"4'-4 3/4"6'-2 1/4"6'-6 1/2"56'-0"6"22'-6"3'-2"8'-8 3/4"11'-9 3/4"5'-3 3/4"8'-0"14'-6"2'-6"40'-0" 19'-0"21'-0" 13'-0"6'-0" 6'-6"6'-6" 10'-6"10'-6" RADON VENT 2x6 PA 2-7 1/4" LSL (DR)LP SOFFIT SD SMOKE CM / OPT. VAULT 69 19 BUILT-INSOPT.OPT. 2-2668 PKT.2'-4 1/4"1'-10 1/2"2424 PICT. @ 8'2424 PICT. @ 8'2'-0 1/2"2'-0 1/2"or 3068 BARN DR.OPT. EXP.ISLAND LINE OF STONE2448 SH @ 8'WD. STEP 4'-4" 5'-9"6'-0 3/4" 6'-0 3/4" 4'-8 3/4"12'-11 1/4" 7'-1 1/4" 2'-0" 1'-4" 7'-10"15'-0 1/2" 2'-7 1/2"2'-4"6'-2 3/4"3'-6"3'-0 1/2"4'-0"2'-8 1/4"2'-0"6'-0"5'-0"12" CANT.9'-4"5'-2"2'-6"36" H. WALL w/ WD. CAP 1'-3"2 3/4" 2'-11 1/2"7 3/4"6'-4 1/4"7'-8"4'-0"9'-8"3'-9"3'-10"3'-5"3'-5"3'-0"3'-0"3'-0"2-2x102-2x102-2x102-2x104 1/2"4 1/2" 8'-10 1/2"MANUF. TRUSSES24 O.C.FP CHASE FALSE 2-9 1/2" LSL (CONT.)2-9 1/2" LSL 2-2x10 (2) TR (2) TR 2-2x10 2-9 1/2" LSL P.H. TR TB 59 3068 PKT. 3'-5" 2-7 1/4" LSL (DR)14" LP COL. 4x4 TRTD. COL. 19'-6" 4"6'-1"13'-8"2'-3 1/4"11'-6 3/4"33'-0"5'-6"210687'-9 1/4"2668 (5) SH.246812'-9"4" TR 12'-8"ELEC. MICRO/ OVEN OPT. UPGRADED KITCHEN DW GAS COOKTOPHOOD VENT ABV.(VENT TO OUTSIDE) REF. KITCHEN OPT. EXP.ISLAND 2 9 39 5'-8 1/4"Girder Truss per sections. CS-PF CS-PF(3)14" LVL -Min. 15" clearance to any obstruction from center of W.C., 24" in front(typ). 5 9 07-00-BUYERPROJECT # BUYER S/O BUYER S/O REVISIONS: STARTED: AGENT:X XLOT 3, BLOCK 10 SUMMER'S CREEK17858 HAMBURG DR. LAKEVILLE, MN"NANTUCKET" 1650 VILLA HOMEMARK ELLIOTT HOMES1-7-2021 PERMIT 1-7-2021 REDLINES 5-24-21 GARAGE 6-1-21 CALCS OF SHEET SCALE: 1/4" = 1'-0" SECTION1 5 N.T.S. HOUSE / DECK CONNECTION DETAIL4 5 3/4" T & G FLOOR NOTE: SUBFLOOR JOINTS SHALL BESTAGGERED FROM FLOOR TRUSS ORJOIST JOINTS R=0.61 R=49.00 R=50.25 R=0.58 R=.061 TOTAL TRUSSES - 24" OC BLOWN INSULATION INTERIOR AIR FILM VAPOR BARRIER 15/32" OSB SHTG. 15# FELT EXTERIOR AIR FILM ICE AND SNOW SHIELD 30 YR. ARCH. ASPHALT SHINGLES 5/8" GYP BD ALUM. SOFFIT & FASCIA 1/2" GYP BD INTERIOR AIR FILM TOTAL SIDING PER SPECS 2x6 STUDS 16" OC R=1.06 R= R= R=21.00 R=0.45 R=0.17 R=23.36 VAPOR BARRIER FULL WALL BATT INSUL. EXTERIOR AIR FILM R=0.68 7/16" OSB SHTG. 8" AGGREGATE 6 MIL POLY. LAP SEAMS 12"1'-4"HEEL HT.1/2" GYP. SHEATHING ON GARAGE WALLS5/8" TYPE 'X' GYP. BD. ON GARAGE CEILS. 18" FLOOR TRUSSES1'-6 3/4"9'-1 1/8"T.O. LOOKOUT T.O. SUBFLR. T.O. PLATE TRUSSES @ 24" O.C. (DESIGNED BY MFR) 6 12 R-49 INSUL.9'-4"GARAGE 4" SLOPED CONC. W/ REBAR PER ENGINEERS REPORT 9'-4" POURED WALL DRAIN TILE 10" POURED WALL R-5 INSUL. ATINTERIOR FOUND.9'-1 1/8"O. BATH OWNERS BDRM. 20x8 CONC. FTG.16x8 CONC. FTG. 16x8 CONC. FTG. NOTE: TOP HUNG TRUSSES AT FRONT OF HOME (10'-0" H. FDN. WALL) SPRAY FOAM RIM SPRAY FOAM RIM 8'-2" +/-FOUND. HELD IN 2" FOR INSULATION TYP. NOTE: (INSUL. FLUSH w/ SHTG.) CANT. 2x8 SILL PLT. 1-1/2" 3 1/2" CONC. FLOOR 2" RIGID INSULATION R-10 w/ WATCHDOG WATERPROOF COATING AROUND HOUSE FOUND.8 1/4"FUT. BDRM. #5 R.I. BATH 8 1/4"4"6"HEEL HT.6 12 WITH SILL SEALER 2x6 TREATED SILL PER CITY CODE ANCHOR STRAPS 3/4" RIGID INSUL. FOR THERMAL BREAKGRADE RIGID INSUL. JOIST W/ 2-3/8" LAG BOLTS ICE & WATER EXTENDS 5" UP SHEATING UNDER INSTALL TOP OF LEDGER 3 5/8" BELOW TOP OF 3/4" SUBFLOOR (THIS ALLOWS 5/4 X 4 THRESHOLD AT DOOR) HANGER TREATED 2X10 LEDGER RUN HOUSE WRAP BEHIND LEDGER (LEAVE 6" TAIL @ TOP, BOTTOM, & SIDES) HOUSEWRAP @ 24" O.C. -OR- EMBED 2" MIN. 8 INCHES O.C. MAX OR EQUAL,W/ "LEDERLOK" FASTENERS CONT. 2X4 RIBBON SPRAY FOAM INSUL. R-21 MIN. RIM BOARD TREATEDJOIST JOIST RIM BD.SKIRT 1" HOUSE END OF DECK HOUSE LATERAL LOAD SIMPSON DTT1Z DECK-TO CONNECTOR - (4) PER DECK OR 8-10DX1 1/2" NAILS 6-SD#9X1 1/2" SCREWS HDG WASHER OR SDWH 3/8" HDG LAG SCREW WITH TIMBER-HEX HDG SCREW (SHOWN) INTO TOP PLATE, STUDS, OR HEADER CONT. 2X8 RIBBON DRAIN TILE 3/4" WASHED ROCK CONTINUOUS UNDER SLAB0'-16" SILT FABRIC FOUNDATION WALL CONC. FTG. 4" DRAIN TILE 2 SCALE: NO SCALE5 TOP OF FDN.RIM DETAIL3 SCALE: NO SCALE5 2" RIGID INSULATION R-10 w/ WATCHDOG WATERPROOF COATING AROUND HOUSE FOUND. 2" RIGID INSULATION R-10 w/ WATCHDOG WATERPROOF COATING AROUND HOUSE FOUND. 2x8 TRTD. SILL SHEATHING FLUSH WITH INSULATION NOTE: FOUNDATION TO BE HELD IN 2" FROMSHEATHING & OUTSIDE DIMENSIONS. CANTED 1-1/2" 6907-00-BUYERPROJECT #BUYER S/OBUYER S/OREVISIONS:STARTED:AGENT:XXLOT 3, BLOCK 10 SUMMER'S CREEK 17858 HAMBURG DR. LAKEVILLE, MN "NANTUCKET" 1650 VILLA HOME MARK ELLIOTT HOMES1-7-2021 PERMIT1-7-2021 REDLINES5-24-21 GARAGE6-1-21 CALCSOFSHEETSCALE: 1/4" = 1'-0"SECTION16N.T.S.PORTAL FRAME DETAIL26N.T.S.RADON DETAIL364" LEDGE11 7/8" OSB STRINGERW/ 2X4 BRACING10 1/2" BULLNOSE LSL TREAD1X8 PINE S4S RISERNOTE:MAX RISE= 7 3/4"MIN. RUN= 10"6'-8" CLEAR HEADROOMBATH 2BEDROOM #2GREAT RM.3/4" T & G FLOORNOTE: SUBFLOOR JOINTS SHALL BESTAGGERED FROM FLOOR TRUSS ORJOIST JOINTS8" AGGREGATE6 MIL POLY. LAP SEAMS 12"18" FLOOR TRUSSES9'-1 1/8"T.O. SUBFLR.T.O. PLATETRUSSES @ 24" O.C.(DESIGNED BY MFR)R-49 INSUL.9'-4"W/ REBAR PERENGINEERS REPORT9'-4" POURED WALLDRAIN TILE 10" POURED WALLR-5 INSUL. ATINTERIOR FOUND.20x8 CONC. FTG.16x8 CONC. FTG.NOTE: TOP HUNG TRUSSESAT FRONT OF HOME(10'-0" H. FDN. WALL)SPRAY FOAM RIMSPRAY 8'-2" +/-FOUND. HELD IN 2"FOR INSULATION TYP.NOTE:(INSUL. FLUSH w/ SHTG.)CANT. 2x8 SILL PLT. 1-1/2"3 1/2" CONC. FLOORCONC. STOOP2" RIGID INSULATIONR-10 w/ WATCHDOGWATERPROOF COATINGAROUND HOUSE FOUND.PORCHMECH. / STORAGEFUT. FAMILY ROOMKITCHEN8 1/4"35ALUM. SOFFIT & FASCIA1'-4"HEEL HT.612 FOAM RIM6121'-6 3/4"T.O. LOOKOUTSIMPSON STRONG TIE Ab46zHEADERHURRICANE CLIP ATTACHEDTO COLUMN& BEAMTAPEREDLP COLUMN6124x4 TRTD. COL.2x OVER 10" TRIMGIRDER1'-6"1'-2"WITH SILL SEALER2x6 TREATED SILLPER CITY CODEANCHOR STRAPS3/4" RIGID INSUL. FOR THERMAL BREAK20X8GRADERIGID INSUL.SIMPSON STHD14 HOLD DOWNSIMPSON LSTA36 STRAP ON INSIDE FACE OF WALL5/8" ANCHOR BOLT1/2" OSB SHEATHINGHEADER- SEE PLAN FOR SIZEFASTEN SHEATHING TO HEADER WITH 8d COMMON ORGALVANIZED BOX NAILS IN 3" GRID PATTERN ASSHOWN, AND 3" O.C. IN ALL FRAMING MEMBERS TYP.SHEATHING SPLICE (IF NEEDED) MUST BELOCATED WITH-IN 24" OF THE MID HEIGHTOF THE DOOR OPENING. PROVIDE 2-2X6BLOCKING BEHIND SPLICEFASTEN TOP PLATE TO HEADER WITH2 ROWS OF 16d SINKER NAILS 3" O.C.BLOCK BACK SIDE OF HEADER FLUSH WITH STUDSAT STRAP LOCATIONSUNEXCAVATED SOILALL SLABS WILL HAVE A MIN. 4" CLEAN AGGREGATE, COVERED BY6 MIL POLY. THIS POLY WILL HAVE 12" LAP AT ALL SEAMS. ALL TEARS ORPUNCTURES WILL BE SEALED OR COVERED BY POLY. ALL OPENINGS WILL BESEALED USING POLYURETHANE CAULK OR ELASTOMERIC SEALANT AT ALL OPNGS.AN INSTALLED 3" GASTIGHT PVC PIPE WILL BE CONNECTED TO THE DRAINTILE SYSTEM. A "T" FITTING WILL BE INSTALLED WITH 10 L.F. EACH ENDOF THE "T", OF PERFORATED PIPE, INTO THE DRAIN TILE SYSTEM. THE SHORTEST ROUTE WILL BE USED TO EXIT THE ROOF SYSTEM, WITH A MAX. OF 2 90DEGREE ELBOWS. IN UNCONDITIONED AREAS, THE RADON EXHAUST PIPE WILLBE INSULATED WITH AN R4 SLEEVE. THIS PIPE WILL BE LABELED "PASSIVERADON" AT ALL ACCESSIBLE LOCATIONS.AT ROOF EXIT LOCATIONS, MAINTAIN A 10' DISTANCE TO ANY WINDOWLOCATION, 2' BELOW EXHAUST POINT AND ANY ADJACENT STRUCTURE. THELOCATION OF THE EXIT POINT, IN TRUSS AREA, WILL BE CLEAR OF ANYOBSTRUCTIONS WITHIN 24" HORIZONTALLY AND 36" VERTICALLY. INSTALL AN OUTLET AND PULL CHORD LIGHT FOR FUTURE EXHAUST FANADDITION. 7 9 07-00-BUYERPROJECT # BUYER S/O BUYER S/O REVISIONS: STARTED: AGENT:X XLOT 3, BLOCK 10 SUMMER'S CREEK17858 HAMBURG DR. LAKEVILLE, MN"NANTUCKET" 1650 VILLA HOMEMARK ELLIOTT HOMES1-7-2021 PERMIT 1-7-2021 REDLINES 5-24-21 GARAGE 6-1-21 CALCS OF SHEET SCALE: 3/16" = 1'-0" ROOF PLAN1 7 2'-0"RIDGE 1'-0"6:122'-0"RIDGE1'-6"12:126:121'-0" NOTE: SEE ROOF TRUSS LAYOUT FOR TRUSS DIRECTION AND GIRDER LOCATIONS PROVIDED BY MANUFACTURER PROVIDE ATTIC VENTILATION EQUAL TO 1/150th ATTIC AREA. IF 50% OR MORE IS PROVIDED IN UPPER PORTION OF THE ROOF AND REMAINDER IS PROVIDED IN SOFFIT VENTS, IT MAY BE REDUCED TO 1/300th ATTIC AREA. ICE AND WATER SHIELD 6'-0" IN FROM EAVES 1'-6" ON EACH SIDE OF VALLEY WHERE WALLS MEET ROOF ICE & WATER SHIELD SHOULD RUN UP WALL 1'-6" AND OUT FROM WALL 1'-6" NOTE: NOTE: NOTE: 12:12 1'-6"1'-0"VALLEYVALLEY4'-4 1/8"7'-0"VALLEYVALLEYRIDGE SCALE: 1/4" = 1'-0" MAIN FLR. ELECTRICAL PLAN 8 9 07-00-BUYERPROJECT # BUYER S/O BUYER S/O REVISIONS: STARTED: AGENT:X XLOT 3, BLOCK 10 SUMMER'S CREEK17858 HAMBURG DR. LAKEVILLE, MN"NANTUCKET" 1650 VILLA HOMEMARK ELLIOTT HOMES1-7-2021 PERMIT 1-7-2021 REDLINES 5-24-21 GARAGE 6-1-21 CALCS OF SHEET SCALE: 1/4" = 1'-0" LOWER LEVEL ELECTRICAL PLAN SS TVABV. FP.NOTE: TECH TUBE TV W.P.RGH.-IN FAN G.F.I.P.S3S3OPT. LTS.PENDANT 3 SS C/L 7'-6"3'-2"4'-9 1/2"TV DW GAS RANGEMICRO ABV. LNDRY. DRYERWASHER (VENT TO OUTSIDE) REF. KITCHEN GREAT ROOM FOYER PORCH O. BATH GARAGE O. CLST BATH 2 BEDROOM #2 OWNERS BDRM. SMOKECM / SD ATTICACCESSMUDRM. DINING SD SMOKECM / G.F.I.P. S G.F.I.P.G.F.I.P.W.P. S S S S S SS 3 S3S3S4G.F.I.P.S3S3SS3 S3 S3 S3 S3 SSS3DISP S SS3 S TO LIGHT RGH.-IN FANOPT. SS G.F.I.P. GDO S G.F.I.P.SELEC.DUPLEX CONVENIENCE OUTLET DUPLEX OUTLET ABOVE COUNTER WEATHERPROOF DUPLEX OUTLET HALF-SWITCHED DUPLEX OUTLET DUPLEX OUTLET IN FLOOR 220 VOLT OUTLET WALL SWITCH THREE-WAY SWITCH FOUR-WAY SWITCH CEILING MOUNTED INCANDESCENT LIGHT FIXTURE WALL MOUNTED INCANDESCENT LIGHT FIXTURE RECESSED INCANDESCENT LIGHT FIXTURE LIGHT FIXTURE WITH PULL CHAIN TRACK LIGHT FLOURESCENT LIGHT FIXTURE EXHAUST FAN EXHAUST FAN/LIGHT COMBINATION CHIMES (OPTIONAL) SMOKE DETECTOR TELEPHONE (OPTIONAL) TELEVISION (OPTIONAL) THERMOSTAT ELECTRIC METER ELECTRIC PANEL SPEAKER (OPTIONAL) TV T M CH SD P.C. S S S 4 3 W.P. ELECTRICAL KEY DUPLEX OUTLET (GROUND FAULT PROTECTED)G.F.I.P. RECESSED INCANDESCENT EYE BALL FIXTURE CARBON MONOXIDE DETECTORCM GARAGE DOOR OPENER OUTLETGDO FLUORESCENT LIGHT PER SPEC FAN/LIGHT COMBO PREWIRE, PROVIDE ADEQUATE SUPPORT 4 BULB FIXTURE 3 BULB FIXTURE 200 AMP SERVICE LIGHTING PACKAGE: T.B.D. LINE TO DRYER: T.B.D.G.F.I.P.EXCH.AIRFURN F.D. WH MECH. / STORAGE WS FUT. BDRM. #5 FUT. FAMILY ROOM R.I. BATH SUMP H20 OPT. RADON VENT SMOKE CM / S S3S TO LIGHT A/C UNIT w/ BRACKET G.F.I.P.G.F.I.P.S 9 9 07-00-BUYERPROJECT # BUYER S/O BUYER S/O REVISIONS: STARTED: AGENT:X XLOT 3, BLOCK 10 SUMMER'S CREEK17858 HAMBURG DR. LAKEVILLE, MN"NANTUCKET" 1650 VILLA HOMEMARK ELLIOTT HOMES1-7-2021 PERMIT 1-7-2021 REDLINES 5-24-21 GARAGE 6-1-21 CALCS OF SHEET49" +/-NO HEARTH PER SPECS 12" SURROUND @ FRONT ONLY GATHERING RM. F.P. ELEV. 9 1 SCALE: 3/8"=1'-0" MANTLE PER SPECS 3'-0"3'-0" 5'-0" 4 KITCHEN ELEV. 9 SCALE: 3/8"=1'-0" 67" FIN. 2 KITCHEN ELEV. 9 SCALE: 3/8"=1'-0" 2'-0" REFRIG. SPACE2'-0"3'-0" 24" DEEP CROWN MLDG END PANEL 2'-0" 3 KITCHEN ELEV. 9 SCALE: 3/8"=1'-0" (SHTRCK. @ SIDES) 60" TV (REF. ONLY) 3'-8 1/2"2'-0"3'-0"2'-0" 12'-6" D.W. SPACE SINK 1'-6"3'-0" CROWN 4'-6"3'-0" MLDG 2'-0"2'-6" 15" D. MICRO RANGE SPACE (VENT TO OUTSIDE) 1'-6" 1'-9" 3'-0" OPT. BUILT-INS 3'-0" 1'-0"1'-9"3'-0"12'-3" 1'-0" OPT. BUILT-INS 3'-8 1/4" 36" W. GAS F.P. R.O. 37"x 34 3/4" x 16 1/4"2'-11 1/4"5'-0" BATH 2 ELEV. 9 6 SCALE: 1/4"=1'-0"7'-0"MIRROR SPACE WASH. LNDRY. ELEV. SCALE: 3/8"=1'-0" DRYER SPACE30"CROWN MOULDING 9 8 C'TOP RAISED OPT. 2" SUPPORT w/ FRONT LOAD W&D3'-5"2'-11 1/4"3'-0"7'-0"WALL MOUNT 7'-9" O. BATH ELEV. 9 7 SCALE: 3/8"=1'-0" 3'-0"1'-9"3'-0" MARBLE C'TOP.WHITE CULT. NOTE: OPT. w/ RAISED TOP WALL MOUNT MIRROR MARBLE C'TOP.WHITE CULT. NOTE: 5 OPT. BUILT-INS @ DINING ELEV. 9 SCALE: 3/8"=1'-0" CROWN MOULDING GRANITE TOP w/ OPT. BUILT-INSGLASSGLASSGLASS GLASSNOTE: PUCK LTS. AT GLASS DOORS 15" D. 1'-9"1'-9"5'-5 1/4" 2'-6"2'-6" 2 UPGRADED KITCHEN ELEV. 9 SCALE: 3/8"=1'-0" 3'-0"2'-0" 12'-6" D.W. SPACE SINK 1'-0"10" CROWN 2'-4"2'-6" MLDG 3'-0"3'-0"1'-0" 2'-0" REFRIG. SPACE2'-0"3'-0" 24" DEEP CROWN MLDG END PANEL 2'-0" 3 9 SCALE: 3/8"=1'-0" 2'-6" 15" D. 1'-6" 1'-9" 3'-0" 1'-0"1'-9" 12'-3" UPGRADED KITCHEN ELEV. COOKTOPOVEN / MICRO 2'-8" (VENT TO OUTSIDE) HOOD VENT BW 07-00-BUYERPROJECT # BUYER S/O BUYER S/O REVISIONS: STARTED: AGENT:X XLOT 3, BLOCK 10 SUMMER'S CREEK17858 HAMBURG DR. LAKEVILLE, MN"NANTUCKET" 1650 VILLA HOMEMARK ELLIOTT HOMES1-7-2021 PERMIT 1-7-2021 REDLINES 5-24-21 GARAGE 6-1-21 CALCS N.T.S. MAIN LEVEL BRACEWALL2 BW N.T.S. BRACEWALL DETAILS3 BW N.T.S. LOWER LEVEL BRACEWALL1 BW GARAGE PORTAL FRAMING PER BUILDING CODE IRC R602.10.6.4 BRACED WALL METHOD CS-WSPBRACED WALLLINE 1BRACED WALL LINE ABRACED WALLLINE 2BRACED WALLLINE B BRACED WALL LINE C4'-0" PANEL4'-0" PANEL8'-0" GYP. PANEL 2'-11" PANEL LNDRY. DRYERWASHER KITCHEN GREAT ROOM FOYER PORCH O. BATH GARAGE O. CLST BATH 2 BEDROOM #2 OWNERS BDRM.ATTICACCESSMUDRM. DINING 3'-6" PANEL3'-1" PANEL6'-7" PANEL3'-5" PANEL 4'-0" PANEL4'-0" PANEL4'-0" PANEL4'-0" PANEL4'-0" PANEL5'-7" GYP. PANEL4'-2" GYP. PANEL 3'-2" GYP. PANEL 3'-6" PANEL 1'-9" PANEL 1'-9" PANEL 7'-6" PANELMIN. 3''x11 1/4'' NET HEADER(STEEL HDR. PROHIBITED) EXTENT OF HEADER W/ SINGLE PORTAL FRAME ONE BRACED WALL PANEL 10'-0'' MAX. HEIGHT(TOP OF HDR.)TOP OF FDN.TOP OF CONC FLOOR AT OPENING MIN. 2-2x4 FRAMING STUD POST CONTINUOUS HEADER WITH DOUBLE PORTAL FRAMES TWO BRACED WALL PANELS 6' TO 18' OPENING FASTEN TOP PLATE TO HEADER W/ 2 ROWS OF 16d SINKER NAILS @ 3'' O.C. TYP. 1000 LB. STRAP OPPOSITE SIDE OF SHEATHING FASTEN SHEATHING TO HEADER W/ 8dCOMMON OR GALV. BOX NAILS IN 3'' GRID PATTERN SHOWN AND 3'' O.C. IN ALLFRAMING(STUDS, BLOCK'G AND SILLS)TYP. MIN. WIDTH PER TABLE R602.10.5 3/8'' MIN. WOOD STRUCTURAL PANEL SHEATH'G. MIN. 2-2x4 MIN. 4200 LB. TIE DOWN DEVICE(EMBED INTO FOUNDATION AND NAILED INTO FRAMING MIN. (2) 1/2'' DIA. ANCHOR BOLT INSTALLED PER R403.1.6 W SEE LEFT FOR TYP. PORTALFRAME CONST. FOR A PANEL SPLICE(IF NEEDED) PANELEDGES SHALL BE BLOCKED AND OCCURWITHIN 24'' OF MID-HEIGHT. ONE ROW OF TYP. SHEATH'G. TOFRAMING NAILING ISREQUIRED. IF 2x4 BLOCK'G. IS USEDTHE 2x4'S MUST BE NAILEDTOGETHER W/ 3 16d SINKER NAILS W/ 2''x2''x3/16'' PLATE WASHER12'-0'' MAX. HEIGHT(TOP OF WALL)FULL HEIGHT OF WALL - SEE TO RIGHT FOR SPLICESPONY WALL HT.EXTENT OF HEADER TENSION STRAP PER TABLE R602.10.6.4 (ONOPPOSITE SIDE OF SHEATHING ANCHOR BOLTSPER SECTIONR403.1.6 BRACED WALL LINE CONTINUOUSLYSHEATHED WITHWOOD STRUCTURAL PANELS TOP OF FLOOR AT OPENING FLOOR FRAMING ASSEMBLY PER PLAN W/ WOOD STRUCTURAL PANEL SHEATHING TOP OF FLOOR AT OPENING FLOOR FRAMING ASSEMBLY PER PLAN WOOD STRUCTURAL PANEL SHEATHINGTO TOP OF BAND OR RIM JOIST NAIL SOLE PLATE TO FLRFRAMING PER TABLE R602.3(1) (2) FRAMING ANCHORS APPLIED ACROSSSHEATHING JOINT WITH A CAPACITY OF670# IN HORIZ. AND VERT. DIRECTIONS SEE LEFT FORTYP. PORTAL FRAME CONST. ON CONCRETE FOUNDATION ON RAISED WOOD FLOOR - FRAMING ANCHOR OPTION TOP OF FLOOR AT OPENING FLOOR FRAMING ASSEMBLY PER PLAN W/ WOOD STRUCTURAL PANEL SHEATHING TOP OF FLOOR AT OPENING FLOOR FRAMING ASSEMBLY PER PLAN WOOD STRUCTURAL PANEL SHEATHING TO TOP OF BAND OR RIM JOIST NAIL SOLE PLATE TO FLR FRAMING PERTABLE R602.3(1) SEE LEFT FOR TYP. PORTALFRAME CONST. ON RAISED WOOD FLOOR - OVERLAP FLOOR OPTION MIN. OVERLAP 9 1/4''WOOD STRUCTURAL PANEL SHEATHING CONTINUOUS OVER BAND OR RIM JOIST MIN. OVERLAP 9 1/4''ATTACH TO RIM/BAND JOIST W/ 8d COMMON NAILS AT 3'' O.C. AS SHOWN DBL TOP PLATE BOTTOM PLATE STUDS AT 16'' O.C. W/ 6d NAILS @ 6'' O.C. 4'-0"8'-0'' MIN., SEE PLANINTERMEDIATE 6''3"W/ 6d NAILS @ 3'' O.C. EDGES NAILED BRACED WALLLINE A-1 FUT. BDRM. #5 FUT. FAMILY ROOM 4'-0" PANEL3'-5" PANEL 2'-7 1/2" PANEL3'-1 1/2" PANEL NEW RESIDENTIAL CONSTRUCTION SWPPP VERIFICATION This form must be completed and submitted with all new residential permit applications. A National Pollutant Discharge Elimination System (NPDES) Construction Stormwater Permit is required for “Construction activity that results in land disturbance of equal to or greater than one (1) acre or if a project is part of a common plan of development that will ultimately disturb greater than one (1) acre,” (NPDES Permit, Section 1.2). Project Site Address: _____________________________________________________________________ Company Name: _________________________________________________________________________ *Primary Company Contact: _________________________________________________________________ *Should a site be deemed noncompliant, this individual will be notified Phone #: ____________________________ Email: ______________________________________________ If you are not covered under a NPDES Construction Stormwater Permit administered by the Minnesota Pollution Control Agency (MPCA), an erosion and sediment control plan MUST be approved as part of the residential building permit application. “Permittees must ensure a trained person will inspect the entire construction site at least once every seven (7) days during active construction and within 24 hours after a rainfall event greater than ½ inch in 24 hours,” (NPDES Permit, Section 11.2). The City of Lakeville reserves the right to request weekly inspection logs. The City of Lakeville may issue a STOP WORK ORDER; withhold building inspections; or, draw on securities/escrows to bring the site into compliance with the NPDES Construction Stormwater Permit (MN R 100001) or erosion and sediment control plan. Contact information of person CERTIFIED to provide weekly onsite erosion and sediment control inspections and corrective actions: Name: ____________________________________ Company: ___________________________________ Phone # (24 hr Contact): ______________________ Email: ______________________________________ Entity that Provided Training: __________________________ Certification Expiration Date: ____________ NOTE: Prior to any land-disturbing activity, all erosion and sediment controls must be installed I understand the above information to be accurate and I have read, understood, and accepted all terms and conditions of the NPDES Permit (MN R 100001). Signature: ________________________________________________ Date:_________________________ Contact the City of Lakeville with questions at erosion@lakevillemn.gov or 952-985-4500 Nick Reimler X02/04/21 KP