Loading...
HomeMy WebLinkAboutLA192148 THE FOLLOWING INFORMATION MUST BE INCLUDED WITH YOUR APPLICATION:  Payment for amount of permit.  For freestanding/monument/pylon sign - a site plan with setback from property line dimensions and art work with dimensions of sign, and engineered design for footings and foundation.  For wall sign, art work with dimensions of sign and drawings of building façade showing location of sign.  If illuminated or if electrical services are needed, a separate electrical permit is required.  If leased space, need to include a letter of approval from the property owner. BUSINESS INFORMATION Name__________________________________________________________________________________ Address________________________________________________________________________________ City ____________________________________State__________________ Zip _____________________ Contact _____________________________________Day Phone # ________________________________ Email Address __________________________________________________________________________ PROPERTY OWNER Name__________________________________________________________________________________ Address________________________________________________________________________________ City ____________________________________State__________________ Zip _____________________ Contact _____________________________________Day Phone # ________________________________ Email Address __________________________________________________________________________ SIGN CONTRACTOR Company Name _________________________________________________________________________ Address________________________________________________________________________________ City ___________________________________ State___________________ Zip _____________________ Contact _____________________________________Day Phone # ________________________________ Email Address __________________________________________________________________________ SIGN DESCRIPTION  Electronic ($100 per sign plus completion of electronic sign license, see Page 2)  Permanent ($75 per sign)  Temporary ($50 per event, up to 60 days per year. Max of one temp sign displayed at a time.) Temporary sign displayed dates: START DATE ________________________ END DATE ________________________ Sign Type and Dimensions  Wall Sign: Width ____________ Height: _______________ Square feet _____________________________  Freestanding: Face Width_________ Height____________ Sq. ft__________ Overall Sign Height _________ Setbacks: Front _________ Side ____________  Temporary Width___________ Height ______________ Sign Square Feet______________________ Display location _______________________ Illuminated Sign:  Internally illuminated  Externally illuminated  Not illuminated Type of Work:  New Sign  Replacement Sign  Alter Existing Sign Changeable Copy:  No Changeable Copy  Manual Changeable Copy  Electronic Changeable Copy (Electronic sign will require annual license review & renewal, see Page 2) Applicant Signature: ____________________________________________Date:_________________ Applicant Printed Name: _______________________________________________________________ SIGN PERMIT APPLICATION & ELECTRONIC SIGN LICENSE City of Lakeville – Planning Department 20195 Holyoke Avenue - Lakeville, MN 55044 952.985.4420 - www.lakevillemn.gov LA192148monument sign SIGN PERMIT APPLICATION & ELECTRONIC SIGN LICENSE Page 2 Electronic Display/Changeable Copy Sign License Single occupancy building with gross floor area over 100,000 sq. ft. within the C-3 District and within the Freeway Corridor District. By signing below you are certifying the electronic signage meets the following performance standards: 1.The display sign shall not change more than once every twenty four (24) hours. 2.The display sign shall not include scrolling, flashing, animation, or other effects. 3.The display must be static and the transition from one static display to another must be instantaneous without special effects. 4.The display image or message must be self-contained, without continuation in content to the next image or message. 5.The brightness of the sign shall not exceed 5,000 NITS after sunrise and before sunset or 500 NITS after sunset and before sunrise each day. 6.The sign shall be equipped with an automatic dimmer control or other mechanism that automatically controls the sign’s brightness to comply with this condition. 7.The display must be designed and equipped to freeze the device in one position if a malfunction of the electronic display occurs. 8.The display must also be equipped with a means to immediately discontinue the display if it malfunctions, and the sign owner must immediately stop the electronic display when notified by the City that it is not complying with the stipulations of this section. 9.The sign shall comply with Chapter 23 of the Zoning Ordinance. Signature_______________________________________ Date______________________________ Print Name______________________________________ Email ________________________________ EXPIRATION AND RENEWAL OF LICENSE: •All licenses expire on December 31st of each year. •License may be renewed only by making application as provided in Section 3-22-4 of the City Code. •Application for renewal shall be made at least sixty (60) days before the expiration date. •Each renewal license shall be issued for a maximum period of one (1) year. •Annual license renewal fee is $50.00 Office Use Only Sign Permit Type: Permanent Sign _____ Temporary Sign _____ Electronic Sign _____ Work Type: New _____ Addition _____ Repair _____ Demolish_____ Replace _____ Alter/Remodel _____ Move _____ Owner: Public _____ Private _____ Zoning District: Commercial _____ Industrial _____ Residential_____ Freeway Corridor _____ Required Inspections: Footing _____ Final _____ Permit Fee: Permit Fee _____________ Miscellaneous ___________ Total ___________________ Comments: ________________________ ________________________ ________________________ ________________________ ________________________ ________________________ ________________________ Approved by:____________________________ Date:___________________________________ (REVISED JUNE 2017) 6-22-21 Allyn G. Kuennen akuennen@lakevillemn.gov (Fee Waived) (Fee Waived) X X X X X X X *Footings only to be installed at this time. Sign portion not permitted until property is platted or lot line is adjusted. *Footing inspection required - call 952.985.4440 for appt. *Email kjenson@lakevillemn.gov after install for final inspection. 24 June 2021 EX PROPERTY LINELEGENDEX CURB AND GUTTERKEOKUK AVENUE15' PARKING SETBACK30' BUILDINGSETBACKPROPOSED LIQUOR STORELOT 2, BLOCK 1F.F.E. 107417,175 ± SFLOT 3, BLOCK 1TASTINGROOM(ALTERNATE)ϭϴΖϮϰΖϮϬΖϮϬΖϮϰΖϭϴΖϮϬΖϭϬΖh/>/E'^d<ϱΖWZ</E'^d<ϵΖϯϬΖϴΖϰ͘ϱΖϮϱΖϮϰΖϮϰΖϮϬΖϭϮΖϮϰΖϭϴΖϭϬΖϮϬΖϲϵΖϱϮΖϱΖϰΖϭϴΖϱ͘ϱΖϵΖϭϮΖEXISTINGPROPERTY LINEALTERNATEPROPERTYLINE1669152418TRUCKDOCK8TRANSFORMERPADPROOF OFPARKING(TYP.)BID ALTERNATETRUNCATEDDOMES(TYP.)AAAAAAAINSTALL 30"X30" R1-1 STOPSIGN (PAID AS INSTALL SIGN 1)AND STOP BARBBEGINTIPOUT CURBENDTIPOUT CURBLIGHTING (SEEARCHITECTURALPLANS)CBEGIN TRANSITIONTO 0" HEIGHT CURB0" HEIGHT CURBB618 CURB AND GUTTERALONG KEOKUK AVENUEB612 CURB ANDGUTTER (TYP.)END TIPOUT CURBBEGIN TIPOUT CURBHEAVY DUTYCONCRETEMONUMENT SIGN (SEEARCHITECTURAL PLANS)PYLON SIGN (SEEARCHITECTURAL PLANS)PROPOSED PROPERTY LINEPROPOSED CURB AND GUTTERPROPOSED CONCRETE PAVEMENTAPEDESTRIAN CURB RAMPBACCESSIBLE PARKING SIGN(PAID AS INSTALL SIGN 2)CONCRETE DRIVEWAY APRON (SEE DETAILS)CNO. BY DATEREVISIONSDATEITEMDESIGNEDCHECKEDFILESTATE AID PROJECT NO.DAKOTA COUNTY PROJECT NO.CITY OF LAKEVILLE PROJECT NO.I hereby certify that this plan was prepared by me or under my directsupervision and that I am a duly Licensed Professional Engineer underthe laws of the state of MinnesotaDate:Reg. No.11/20/2042839.#-'8+..'.+37145176*5+6'2.#061811/20/20- 3 CO 3.1.21PR 2 COMMENTS20-24SOUTHERN PARCEL - SITE DATA SUMMARYZONEC-3, GENERAL COMMERCIALDISTRICTTOTAL SITE AREA136,681 SFPROPOSED PERVIOUS63,153 SFPROPOSED IMPERVIOUS73,528 SFFRONT SETBACK30 FT (BUILDING), 15 FT (PARKING)SIDE AND REAR SETBACK10 FT (BUILDING), 5 FT (PARKING)SOUTHERN PARCEL - PARKING SUMMARYPARKING RATIO REQUIRED1 STALL/200 SF FLOOR AREA(1 STALL/3 SEATS OF TASTING ROOM)STANDARD STALLS PROVIDED93 STALLSADA STALLS PROVIDED4 STALLSTOTAL STALLS REQUIRED77 STALLS(105 STALLS WITH TASTING ROOM)TOTAL STALLS PROVIDED96 STALLS (105 STALLS WITH PROOF)LAKEVILLE COMMERCE CENTEREXISTING LOTSLOT 2, BLOCK 1 136,681 SF (3.14 ACRES)LOT 3, BLOCK 1 59,868 SF (1.37 ACRES)LAKEVILLE COMMERCE CENTERALTERNATE LOTSLOT 2, BLOCK 1116,873 SF (2.68 ACRES)LOT 3, BLOCK 179,676 SF (1.83 ACRES)3LA192148 CONC BLOCK FOUNDATION; - SEE STRUCTURAL THRU WALL METAL FLASHING METAL FLASHING 12" CONC BLOCKS GROUTED SOLID GROUT SOLID T.O. PRECAST BEYOND 2 3 4"2' - 0"4" CONC. BLOCK FOUNDATION; SEE STRUCTURAL BRICK #1 OVER 12" CMU PILLAR MESSAGE CENTER DETAILS (BY GC): DOUBLE-SIDED MANUFACTURER: DAKTRONICS RESOLUTION: 15.85MM CABINET DIMENSIONS 4'-8" X 8'-1" VIEWABLE DIMENSIONS: 4'-2" X 7'-10" COMMUNICATION: 4G LTE WIRELESS COMMUNICATION 2' - 0"1' - 0"6"1' - 0"6"4' - 8"4"2' - 3" 8' - 2"3' - 4" METAL SIGN BOX W/ POLYCARBONATE FACE PRECAST WALL CAP 2 L5.0 LAKEVILLE LOGO DETAILS: (FURTHEST TO STREET ON BOTH SIDES) LAYER #1: 1/8" ALUMINUM BACKER DIGITAL PRINT APPLIED TO FACE LAYER #2: 1/4" ALUMINUM OVERLAY/CUT OUT PAINTED MP00374 BLUE MOUNTING: FLUSH-STUD, EPOXY MOUNTED TO STONE/BASE NOTE: DOUBLE FACE SIGN2 2 10' - 0"ELECTRONIC MESSAGE CENTER 9' - 8"FROST FOOTING CONCRETE BASE -SEE STRUCTURAL2' - 0"6"2' - 0"6"4' - 0"2' - 0"11' - 0"19' - 0"2' - 0"6' - 0"2' - 0" BRICK #1 OVER STEEL STRUCTURE METAL SIGN BOX W/ BLACK FINISH METAL SIGN BOX W/ POLYCARBONATE FACE 6 L5.0 PRECAST WALL CAP EXPOSED I BEAM TO BE PAINTED CITY LOGO ON POLYCARBONATE FACE W/ BACKLIGHTING NOTE: DOUBLE FACE SIGN 2 T.O. PRECAST BEYOND 11"11"2 INDIVIDUAL LETTERS W/ INTERNAL BACKLIGHTING METAL SIGN BOX W/ ROUTED FACE AND BLACK FINISH 3 5 5 WEEP VENTS ALL 4 SIDES SOLID GROUT AIR CAVITY BETWEEN ALL STEEL AND MASONRY UNITS BELOW GRADE, CHAMPHER TOP FOR POSITIVE SLOPE TO WEEP VENTS APPLY BUTUMASTIC COATING TO ALL STEEL BELOW PROPOSDED GRADE ELEVATIONS PER CIVIL GRADE SEE CIVIL 0"-11'-0" 6 6 L5.0 2' - 0"6' - 0"2' - 0"2' - 0"33 2 L5.0 2' - 0"3' - 4"8' - 2" 3' - 4" 3 7' - 6"10' - 0"10' - 0"T U S H I E M O NT G O M ER Y A R C H I T E C T S 7645 LYNDALE AVENUE SOUTH, #100 MINNEAPOLIS, MINNESOTA 55423 -4084 612 . 861 . 9636 FAX: 612 . 861. 9632 W W W . T M I A R C H I T E C T S . C O M PREPARED FOR: Revisions & Addendums © 2020 Tushie Montgomery & Associates, Inc. 06/25/2020 - DD PRICING SET 10/20/2020 - BID PACKAGE #1 - STEEL 10/29/2020 - BP1 - ADDENDUM #1 11/23/2020 - BID PACKAGE #2 11/24/2020 - PROPOSAL REQUEST #1 12/04/2020 - BP2 - ADDENDUM #1 12/08/2020 - BP2 - ADDENDUM #2 ALL ARCHITECTURAL AND ENGINEERING DRAWINGS ARE IN CONFIDENCE AND DISSEMINATION MAY NOT BE MADE WITHOUT PRIOR WRITTEN CONSENT OF THE ARCHITECT. ALL COMMON LAW RIGHTS OF COPYRIGHT AND OTHERWISE, ARE HEREBY SPECIFICALLY RESERVED. I HEREBY CERTIFY THAT THIS PLAN, SPECIFICATION, OR REPORT WAS PREPARED BY ME OR UNDER MY DIRECT SUPERVISION AND THAT I AM A DULY LICENSED LANDSCAPE ARCHITECT UNDER THE LAWS OF THE STATE OF MINNESOTA. Gary Tushie City of Lakeville PRINT NAME: SIGNATURE: DATE: 12/08/20 LICENSE #: 15146 # Revision KeyLAKEVILLE LIQUOR SOUTH20880 KEOKUK AVE.L5.0 SIGNAGE DETAIL 219129A SCALE 1/2" = 1'-0" 2 MONUMENT SIGN SECTION SCALE 1/2" = 1'-0" 3 MONUMENT SIGN ELEVATION SCALE 1/2" = 1'-0" 4 PYLON SIGN ELEVATION SCALE 1/2" = 1'-0" 1 PYLON SIGN PLAN SCALE 1/2" = 1'-0" 5 MONUMENT SIGN PLAN SCALE 1/2" = 1'-0"6 PYLON SIGN SECTION 2 BP2 - Addendum #1 12/04/2020 3 BP2 - Addendum #2 12/08/2020 4 Proposal Request #2 03/01/2021 5 Proposal Request #3 04/09/2021 6 Proposal Request #4 05/28/2021 4 5