Loading...
HomeMy WebLinkAbout17856 Element AveLA180639 EXISTI N G HOUS E EXISTI N G HOUS E GARAG E ELEMENT A V E N U E TNH 926. 1 9 GAR F L O O R 926. 3 2 SERV GAR FLOOR 925.54 C.O. R:916.81 C.O. R:922.86 R:92 3. 5 1 923.0 923. 5 923. 7 923.1 922.9 922.9 (924 .8 ) (918 .3 )(917.8)(924.4)(925. 6) (916.9) (916.8) (923.3)(924. 0)9.4%101010105 5 5 5 EX. SODEX. SODEX. SODEX. SOD N59°42'11" E 20.1 3 Δ =3 0 °1 0 '4 4 " R =1 3 4 .6 7 7 0 .9 3 N89°52'55"E 35.00 120.06N00°07'05"W120.01S3 0 ° 1 7 ' 4 9 "E 61.00 S78°25'36"W 926. 3 925. 6 918. 3 918.1 925.5 PORC H 10.0 0 30.5025.33(926. 0 0 ) (918. 5 ) (923. 8 ) 9.50 4 .00 11.67 33 .67 17.00 3 .00 3 .00 10.00 17 .17 11.17 24 .67 11.00 2 .00 20.67 14 .17 5 .92 21.1 7 FBWO26.67 (918. 5 ) EXTR A E X P O S E D FOUN D A TI O N GARAGE EXISTING HOUSE GARA G E DROP - 1 C 25.9 FD IP #19 0 8 6 FD IP FD IP #22036 27.4 6.6% 3 .00 3 .00 14.67 DENOTES EXISTING CATCH BASIN DENOTES EXISTING HYDRANT DENOTES EXISTING SANITARY MANHOLE DENOTES EXISTING STORM MANHOLE DENOTES EXISTING UTILITY BOX DENOTES EXISTING SERVICE OR CLEANOUT DENOTES IRON MONUMENT FOUND DENOTES IRON MONUMENT SET DENOTES EXISTING POWER POLE DENOTES EXISTING LIGHT POLE DENOTES EXISTING CONSERVATION POST OR WET LAND BUFFER POST DENOTES EXISTING TREE8" TREE 000.0 DENOTES WOOD HUB DENOTES NAIL DENOTES EXISTING RETAINING WALL DENOTES PROPOSED RETAINING WALL DENOTES EXISTING ELEVATION DENOTES PROPOSED ELEVATION DENOTES AS BUILT ELEVATION (000.0) 000.0 DENOTES EXISTING TREELINE DENOTES DIRECTION OF SURFACE DRAINAGE DENOTES EXISTING FENCE LEGEND DENOTES EXISTING F.E.S. LOT AREA : 11,570 SQ. FT. HOUSE AREA : 1,893 SQ. FT. BUILDING COVERAGE AREA : 2,056 SQ. FT. (17.8%) PORCH AREA : 163 SQ. FT. Legal Description: = FINISHED GARAGE FLOOR ELEVATION = BASEMENT FLOOR ELEVATION = TOP OF FOUNDATION ELEVATION HOUSE FINAL GRADE AS-BUILT SURVEY (926.00) (927.00) (919.00) 1. No specific soils investigation has been performed on this lot by the surveyor. The suitability of the soils to support the specific house is not the responsibility of the surveyor. 2.No title information was provided for this survey. This survey does not purport to show all easements of record. 3. See architectural plans for final building dimensions. AREAS: = TOP OF FOUNDATION ELEVATION GARAGE(926.33) BENCHMARK: TNH AT LOT6 BLOCK 2. ELEVATION = 926.19 NOTES: 1. 8'- 4" POURED FOUNDATION. 2. DROP GARAGE 1-COURSE 3. LOWEST ALLOWED FLOOR ELEVATION = 918.4. NOTE: SURVEY PREPARED USING GRADING PLAN PREPARED BY PIONEER ENGINEERING DATED 11-27-17, REVISED 06-20-18. 11x17