Loading...
HomeMy WebLinkAboutLA183985 Revised PlanUP 7'-0 1/16" 2' 1'1' 1'3'2'8'8' 1'-4"2'Finished Grade 5/4 Compostie Decking2X10 Treated JoistsJoist Hanger Deck LedgerLag BoltsDeck Flashing Finished Grade Double 2x10 Rim Beam Triple 2x10 Beam Min. 42" Deep Post AnchorStandoff Bracket Double 2x10 Beam Double 2x10 Rim Beam Kent Lee 16566 Draft Horse Blvd Lakeville MN 55044 2X12 Treated Stringers36" Gripable railing11" treads7.75" Max riser height Trex DeckingW/ Hidden Fasteners 12" Pier Footings6x6 Treated Posts 6x6 Treated Posts 24" Max Cantilever 24" FootingsW/ 6x6 posts Double 2x10 Treated beam1/2" Carriage Bolts Existing Exterior Wall Trex Signiture Series Railing36" High Railing3.75" Max Baluster Spacing 6X6 Cedar Posts DBL. 2X10 Beam Engineered scissor trusses2X6 SPF Sub Fascia 2X6 Cedar Cap 2X4 SPF Knee Walls1/2" OSB Wall Sheathing LP Smartside Vinyl Double hung windows Exterior Porch CedarWrapped in Aluminum Asphalt Roof Shingles15# Tar Paper Aluminum Soffit and Fascia Windows within 24" of doors must be tempered. Concept Approval ONLY Subject to Field Inspection Inspector Date 2020 MN Bldg Code 07/06/2021dmathews Revised plans to switch from screens to windows.