Loading...
HomeMy WebLinkAboutItem 5 continued discussion of ZO amendments 3601 Thurston Avenue Anoka, MN 55303 763.231.5840 TPC@PlanningCo.com 1 MEMORANDUM TO: Daryl Morey FROM: D. Daniel Licht, AICP DATE: 7 July 2021 RE: Lakeville – Zoning Ordinance TPC FILE: 135.01 BACKGROUND The Planning Department initiates an annual review of the Zoning Ordinance, Subdivision Ordinance, and/or City Code to address issues identified in the course of ongoing administration of the City’s development regulations and review of development applications. The Planning Commission held a public hearing on 20 May 2021 to consider proposed updates of the Zoning Ordinance and City Code prepared by City staff and reviewed previously by the Planning Commission and City Council during work sessions. The public hearing was closed and the Planning Commission made recommendations to the City Council for approval of the proposed amendments. The City Council at their meeting on 7 June 2021 adopted the majority of the proposed amendments as recommended by the Planning Commission, but referred the issue of design standards for motor fuel facilities back to the Planning Commission after new information was presented. City staff is also presenting additional language allowing for shared freestanding signs on abutting properties within commercial zoning districts. Amendment of these sections of the Zoning Ordinance were previously noticed as part of the public hearing held by the Planning Commission and no additional notice is required. Exhibits:  Draft ordinance  Shared freeway corridor commercial sign example  Motor fuel canopy elevation example 2 ANALYSIS Shared Signs. The City acquired two abutting lots within the Lakeville Commerce Center plat located west of I-35 and north of 210th Street (CSAH 70). The lots abut I-35 to the east and Keokuk Avenue to the west. The City is developing the south lot with a Lakeville Liquors store and may market the north lot for sale. Administration staff proposed the concept of placing a freestanding pylon sign on one lot oriented to be visible from I-35 and a second freestanding monument sign on the second lot oriented to Keokuk Avenue. Each sign is proposed to display information for the businesses located on each lot. The Zoning Ordinance currently allows one freestanding sign per property and prohibits off- premises signage. Section 11-23-15.Q of the Zoning Ordinance also allows abutting commercial lots to share a single freestanding sign with the same area and height allowances of a single sign. The Burger King and Amoco at I-35 and CSAH 50 are believed to be the only businesses that utilized this provision, but have ceased operations and the sign was removed. The premise of the provision is that it results in a reduction in the number of signs within a given area by combining two freestanding signs into one while increasing visibility for the businesses. The situation presented by the City lots is more unique. The double frontage of the lots to I-35 and Keokuk Avenue creates opportunity for visibility from the freeway corridor and the need for identification from the interior street for directional purposes. We would recommend that a provision be included in the Zoning Ordinance allowing the two proposed signs requiring that one be a freeway-oriented sign and the other located adjacent to the street accesses. with appropriate area and height standards specific to each purpose. The number of signs would not be reduced through this version of a shared arrangement, but the cumulative height and area of freestanding signs allowed separately for the two lots would be. The proposed Zoning Ordinance provision would also include requirements for shared ownership and maintenance agreements to be recorded with each property as part of the sign permit approval. This provision is proposed to be limited to properties within the Freeway Corridor District abutting I-35. And although initiated based on the circumstances of the City owned properties, the proposed Zoning Ordinance amendment allowing abutting commercial lots to share freestanding sign structures would apply to all properties within the I-35 Freeway Corridor District. Motor Fuel Canopies. The owner of the former Hi-Hi Market, which is a convenience store/motor fuel facility located at 8333 210th Street, has proposed exterior remodeling as part of a franchise rebranding that would include LED lighting and colored bands on the canopy. Section 11-37-3.E and Section 11-37-7.B of the Zoning Ordinance require the exterior finish for motor fuel facilities utilize earth tone colors. These sections further allow that 10 percent of the building facade may contain contrasting colors and that the canopy may have contrasting color bands or accent lines not to exceed an accumulative width of four inches provided they not be illuminated. Section 11-16-17.B.1.c of the Zoning Ordinance regulating exterior lighting 3 generally for commercial, industrial, and institutional uses also states that lighting of the facades of a building may only utilize illuminating devices mounted on top and facing downward onto the structure. The Planning Commission initially addressed changes to the Zoning Ordinance recommending allowing LED lighting to be installed on the canopy provided that it not face abutting residential properties and that there are controls for the intensity of the lighting. The property owner presented City staff with plans for the proposed canopy changes on 7 June 2021 just prior to the City Council meeting. The proposed elevations include the LED lighting but also colored bands consistent with the branding of this motor fuel facility identity. The proposed color bands are 26 inches in height and include a 6.5-inch LED lighting stripe mounted on the 36-inch height of the canopy elevation. The sign plan also illustrates that the canopy supports utilize contrasting blue color. While the LED lighting would be allowed by the ordinance amendment as originally drafted, the width of the color bands and LED lighting conflict with the existing limit of 4-inch stripes for such franchise identification. The limitation on the use of non-earth tone, contrasting colors was established with the Motor Fuel Facilities Study completed during the 1990s and subsequent amendments to the Zoning Ordinance. The basis of the limitations has been that motor fuel facilities used contrasting color on the exterior elevations of the principal building and canopy for branding identification essentially as an expansion of signage for the location. Consistent with the purpose and intent of exterior material requirements and sign ordinance provisions of the Zoning Ordinance, community aesthetics are to supersede corporate identity. In consideration of the intent of the color banding on the motor fuel canopy, our office recommends that the Zoning Ordinance provisions be further modified. Use of contrasting colors, including LED lighting is to be allowed on the canopy elevations not facing abutting residential properties. The extent of the contrasting colors and LED lighting would not be allowed to exceed 75 percent of the canopy elevation that it is affixed to. The existing provision of the Zoning Ordinance that placement of a wall sign upon the canopy would be in lieu of wall signs on the principal building would remain. This approach reflects the purpose of the colored banding for business identification purposes but is consistent with the intent of the exterior finish and sign provisions of the Zoning Ordinance. CONCLUSION The Planning Commission will consider the additional amendments to the Zoning Ordinance at their meeting on 15 July 2021. City staff recommends approval of the proposed Zoning Ordinance amendments in the form attached hereto. c. Justin Miller, City Administrator Andrea McDowell-Poehler, City Attorney 1 ORDINANCE NO. _________ CITY OF LAKEVILLE DAKOTA COUNTY, MINNESOTA AN ORDINANCE AMENDING THE LAKEVILLE CITY CODE. THE CITY COUNCIL OF THE CITY OF LAKEVILLE, MINNESOTA ORDAINS: Section 1. Section 11-23 -19.F of the Zoning Ordinance (Signs – District Regulations) is hereby amended to add the following provisions: 2. Separate commercial uses on properties with a common lot line that abut a principal arterial roadway may each locate a sign on the allowed freestanding structure for each lot subject to approval by the Zoning Administrator; provided, that: a. Location: (1) One (1) of the allowed signs shall be located in a yard abutting the street to which at least one (1) of the lots have access. (2) One (1) of the allowed signs shall be located in a yard abutting th e principal arterial right-of-way. b. The sign in the yard abutting the street to which the lot(s) have access may not exceed one hundred (100) square feet each side with a maximum height of twenty feet (20'). c. The sign in the yard abutting the principal arterial right-of-way shall comply with the following provisions: (1) Area: The area of a sign may not exceed one hundred fifty (150) square feet each side, except that the area of a sign for single occupancy buildings with a gross floor area of one hundred thousand (100,000) square feet or larger shall not exceed four hundred (400) square feet. (2) Height: (A) The maximum height of the sign shall not exceed thirty feet (30'), except that the height of the sign for single occupancy buildings with a gross floor area of one hundred thousand (100,000) square feet or larger shall not exceed fifty feet (50'). 2 (B) For convenience food, hotel, motor fuel and restaurant uses developed on properties with an elevation below that of the centerline of I-35, measured at the closest distance between the sign location and centerline of I-35, the height of a freestanding sign may increase to be not more than thirty feet (30') above the centerline elevation of I-35 with a total height not to exceed seventy feet (70'). d. An agreement addressing construction, maintenance, and repair responsibilities and access rights is established and filed with the Dakota County Recorder with the titles of the two (2) properties involved in the collocated freestanding sign(s) prior to issuance of a sign permit with amendment or cancellation of the agreement allowed only upon written approval by the Zoning Administrator. Section 2. Section 11-37 -3.E.6 of the Zoning Ordinance (Motor Fuel Facilities – Motor Fuel Sales, Not Including Truck Stops or Automobile Repair) is hereby amended to read as follows: 6. Use of contrasting colors not defined as earth tones: a. Ten percent (10%) of the principal building facade may contain contrasting colors. Contrasting colors shall be those colors not defined as earth tones. b. The canopy elevation(s) may have contrasting colors bands or accent lines not to exceed an accumulative width of four inches (4"). The color bands shall not illuminated.as follows: (1) The contrasting colors shall be located on ly on an elevation not facing a residential district and shall not be used on the canopy supports or other elements of the structure. (2) The area of the contrasting colors and wall sign(s) shall not exceed seventy-five (75%) of the area of an individual canopy elevation where it is allowed. (3) Use of lighting on the canopy elevation shall be limited to LED sources that is to be shielded and complies with the provisions of Section 11-23-15.F of this title. (4) The use of contrasting colors upon the canopy elevations shall be in lieu of a walls sign(s) mounted upon the principal building. Section 3. Section 11-37-3.F.4 of the Zoning Ordinance (Motor Fuel Facilities – Motor Fuel Sales, Not Including Truck Stops or Automobile Repair) is hereby amended to read as follows: 4. Canopy lighting shall consist of canister spotlights recessed into the canopy with no portion of the light source or fixture extending below the bottom 3 face of the canopy. Total canopy illumination may not exceed the limits established by subsection 11-16 -17.A of this title. The fascia of the canopy shall not be illuminated except as allowed by Section 11-37-3.E.6 of this title. Section 4. Section 11 -37-7.B.6.f of the Zoning Ordinance (Motor Fuel Facilities –Truck Stops or Automobile Repair) is hereby amended to read as follows: f. Use of contrasting colors not defined as earth tones: (1) Ten percent (10%) of the principal building facade may contain contrasting colors. Contrasting colors shall be those colors not defined as earth tones. (2) The canopy elevation(s) may have contrasting colors bands or accent lines not to exceed an accumulative width of four inches (4"). The color bands shall not illuminated.as follows: (A) The contrasting colors shall be located only on an elevation not facing a residential district and shall not be used on the canopy supports or other elements of the structure. (B) The area of the contrasting colors and wall sign(s) shall not exceed the seventy five percent (75 %) of the area of an individual canopy elevation where it is allowed. (C) Use of lighting on the canopy elevation shall be limited to LED sources that is to be shielded and complies with the provisions of Section 11-23-15.F of this title. (D) The use of contrasting colors upon the canopy elevations shall be in lieu of a walls sign(s) mounted upon the principal building. Section 5. Section 11 -37 -7.B.7.d of the Zoning Ordinance (Motor Fuel Facilities –Truck Stops) is hereby amended to read as follows: d. Canopy lighting shall consist of canister spotlights recessed into the canopy with no portion of the light source or fixture extending below the bottom face of the canopy. Total canopy illumination may not exceed the limits established by subsection 11 -16-17.A of this title. The fascia of the canopy shall not be illuminated as allowed by Section 11-37-7.B.6.f of this title. ADOPTED this ____ day of ________, 20 21 , by the City Council of the City of Lakeville, Minnesota. 4 CITY OF LAKEVILLE BY:_________________________________ Douglas P. Anderson, Mayor ATTEST:__________________________________ Charlene Friedges, City Clerk No Image Available Back ElevationNotes- Any Additional Fascia Should Be Removed. ACM Is Meant To Fit Over First Layer Of Fascia Only. - If Fascia Height Is Less Than 30” It Will Need To Be Built Up To At Least 30” Inches.Right ElevionLeft ElevationFront ElevationSignoff indicates that the above product has been permitted with any municipalities involved. By signing this document, the product will be manufactured to .Approved By:Date: MAP2 Northfield Plaza, Ste 211 Northfield, IL 60093CANOPY 1 OF 1See Site Notes page for specific paint codes and contact info. *REMOVE ALL EXISTING SIGNAGE*EH1IJLH2MB Install Dimensional Bullnose Fascia With Light BarC Install Flat ACM With Decal Applied With No Lightbar DInstall New White ACMFederal Heath SuppliedJobber SuppliedPaint Existing Flat ACM WhiteLeave WhiteInstall Bullnose DecalFInstall Amoco T&O 34” T&O (restricted P&Z only)60” T&O30” T&0 (restricted P&Z only)36” T&OGInstall Amoco Channel Letters15” Channel Letters (restricted P&Z only)22” Channel LettersPaint Canopy Columns Amoco White & Amoco Dark Blue (Per Standards Shown on Note Page)Paint As Shown In GuideInstall Flag Signs 10'6" From The GroundApply Amoco Light Blue Stripe 10'0" From The GroundCanopy Corners:Are NOT 90°Are 90°Canopy Detail (Full Canopy Detail Page After Elevation)KCanopy Deck To Be Amoco WhiteThis is an original concept drawing created by Big Red Rooster Flow, LLC. It is submitted for use in connection with the project being planned for you by BRRFlow. All or any part of this design (except registered trademarks) remains the property of BRRFlow. This drawing is not to scale. For all questions regarding the scope of the project, please contact Emily Wendt 847.971.6981 or The Brand Image Adviser, Larry Rowlands 708.495.581436”48'1’-3”6’-2”1’-3”60” AMOCO letter logo signF3ODFHYDODQFHDQGVNLUWJUDSKLFVVRWKDWWKH\IRUPDFLUFOHB64536251665510'-6”sign10'-0”stripeIJH181'6951061151267581’-3”13’-3”1’-3”81'22” AMOCO letter logo signGB48'1’-3”6’-2”1’-3”60” AMOCO letter logo signFBD16' TO THE EDGEJOBBER: WORLD FUEL SERVICES SITE LEVEL: B DESIGNER: CONNOR DANIELS REVISON #: JR1ADDRESS: 8333 210TH ST W , LAKEVILLE , MN 55044SVB: 1182600DATE: 01.07.2021 CANOPY DETAIL74"15"15"60"26"bnoseequalequal36"fascia6.5”Amoco Lt BlueLensAmoco Dk BlueShaped ACM BullnoseAlign bottom of T&O Logo Signwith bottom of fascia74"15"15"60"26"bnoseequalequal36"fascia6.5”Amoco OrangeLensAmoco RedShaped ACM BullnoseAlign bottom of T&O Logo Signwith bottom of fasciaFF26"bnose5"5"36"fascia13’- 3"22”equalequal15"15"Amoco OrangeLensAmoco Lt BlueLensApproved By:Date: 2 Northfield Plaza, Ste 211 Northfield, IL 60093This is an original concept drawing created by Big Red Rooster Flow, LLC. It is submitted for use in connection with the project being planned for you by BRRFlow. All or any part of this design (except registered trademarks) remains the property of BRRFlow. This drawing is not to scale. For all questions regarding the scope of the project, please contact Emily Wendt 847.971.6981 or The Brand Image Adviser, Larry Rowlands 708.495.5814 CANOPY DETAILDispenser graphics should bow out in the direction of the perimeter of the canopy.storedirection ofswooshdirection ofswooshstreetLight ApproachCardBrochureHolderCall 1-888-BPHELPU(1-888-274-3578),option 3, 3, 3,2to order POP hardwareCrind Stripclearance16'-0"1'3" radius5/8"1/4"6"2 5/8"1 3/8"1"2'-0"Approved By:Date: 2 Northfield Plaza, Ste 211 Northfield, IL 60093This is an original concept drawing created by Big Red Rooster Flow, LLC. It is submitted for use in connection with the project being planned for you by BRRFlow. All or any part of this design (except registered trademarks) remains the property of BRRFlow. This drawing is not to scale. For all questions regarding the scope of the project, please contact Emily Wendt 847.971.6981 or The Brand Image Adviser, Larry Rowlands 708.495.5814 This is an original concept drawing created by Big Red Rooster Flow, LLC. It is submitted for use in connection with the project being planned for you by BRRFlow. All or any part of this design (except registered trademarks) remains the property of BRRFlow. This drawing is not to scale. For all questions regarding the scope of the project, please contact Emily Wendt 847.971.6981 or The Brand Image Adviser, Larry Rowlands 708.495.5814CRIND POPInsert and removecard quicklyorThis Sale$GallonsAlternate selection buttonsfor screen prompts aboveSEESCREENABOVE187PUSH HEREMINIMUM OCTANE RATING(R + M)/2 METHOD89PUSH HEREMINIMUM OCTANE RATING(R + M)/2 METHOD93PUSH HEREMINIMUM OCTANE RATING(R + M)/2 METHOD0000888800000000888800000000888800001*REMOVE ALL UNAPPROVED SIGNAGE FROM DISPENSERS*See Site notes page for specific paint codes and contact info. Crind Hardware Inverted Pump Sign Hardware (NY & NJ ONLY)Install Amoco Credit card acceptance decalInstall Amoco White Dispenser Riser Panel OverlayPanel surrounding electronics must be one of the following colors and/or any combination of Amoco Pearl, White, Grey, Beige and/or Black. Blue and Red are NOT approved Amoco colors. Current electronic panel meets Amoco Standards Current electronic panel DOES NOT meet Amoco standardsApply Amoco Branded Grade DecalsApply Please Prepay First DecalInstall Amoco Pump Appropriate skirt Install Amoco Branded Skirt (as shown) Apply Pump Numbers (Decal supplied should have Amoco Retail Red number with clear background)Install Driver Rewards Brochure HolderApply Regulatory Graphic provided by Amoco (Additional graphics may be required by your state.)Install applicable octane decalsInstall Correct Nozzle Covers (See Forecourt Notes Page)Install nozzle surround for Amoco Branded DieselInstall Amoco Branded Diesel Actuator ButtonApply vertical grade decal for Branded Amoco DieselApply Handicap decal Apply 10% Ethanol decal (As required by code)Install Amoco Spec Valance (as shown)Apply Riser DecalABCDEFGIJKLMNOPQRBIG RED ROOSTER FLOW2 Northfield Plaza, Ste 211 Northfield, IL 6009318"White RisersRRKQGBGFDJIOASPETSTDo not use phone while fueling decalTap to pay interfaceNotes4 NEW GILBARCO ENCORE 700S 3+0Insert and removecard quicklyorThis Sale$GallonsAlternate selection buttonsfor screen prompts aboveSEESCREENABOVE000088880000000088880000000088880000PUSH HERE87MINIMUM OCTANE RATING(R + M)/2 METHOD93PUSH HEREMINIMUM OCTANE RATING(R + M)/2 METHOD89PUSH HEREMINIMUM OCTANE RATING(R + M)/2 METHOD93PUSH HEREMINIMUM OCTANE RATING(R + M)/2 METHOD000088880000$These filler panels will need to be purchased through the dispenser manufacturer, Gilbarco. Amoco Parts will not provide this on the estimate.This is only needed if you are reimaging an existing dispenser and this area is an unapproved dispenser color (Red or Blue).CCUnless prior approval has been given by the Amoco Image Manager: The decals shown in this rendering are the only decals approved by Amoco. The failure to remove existing decals, or the installation of any additional decals will be considered non-compliant with Amoco Brand Standards.JOBBER: WORLD FUEL SERVICES ADDRESS: 8333 210TH ST W , LAKEVILLE , MN 55044SVB: 1182600 This is an original concept drawing created by Big Red Rooster Flow, LLC. It is submitted for use in connection with the project being planned for you by BRRFlow. All or any part of this design (except registered trademarks) remains the property of BRRFlow. This drawing is not to scale. For all questions regarding the scope of the project, please contact Emily Wendt 847.971.6981 or The Brand Image Adviser, Larry Rowlands 708.495.5814CRIND POPInsert and removecard quicklyorThis Sale$GallonsAlternate selection buttonsfor screen prompts aboveSEESCREENABOVENotes2 NEW GILBARCO ENCORE 700S 3+1 W AMOCO DIESELMINIMUM CETANE RATING40PUSH HERE00008888000000008888000000008888000000008888000087PUSH HEREMINIMUM OCTANE RATING(R + M)/2 METHOD89PUSH HEREMINIMUM OCTANE RATING(R + M)/2 METHOD93PUSH HEREMINIMUM OCTANE RATING(R + M)/2 METHOD11*REMOVE ALL UNAPPROVED SIGNAGE FROM DISPENSERS*See Site notes page for specific paint codes and contact info. Crind Hardware Inverted Pump Sign Hardware (NY & NJ ONLY)Install Amoco Credit card acceptance decalInstall Amoco White Dispenser Riser Panel OverlayPanel surrounding electronics must be one of the following colors and/or any combination of Amoco Pearl, White, Grey, Beige and/or Black. Blue and Red are NOT approved Amoco colors. Current electronic panel meets Amoco Standards Current electronic panel DOES NOT meet Amoco standardsApply Amoco Branded Grade DecalsApply Please Prepay First DecalInstall Amoco Pump Appropriate skirt Install Amoco Branded Skirt (as shown) Apply Pump Numbers (Decal supplied should have Amoco Retail Red number with clear background)Install Driver Rewards Brochure HolderApply Regulatory Graphic provided by Amoco (Additional graphics may be required by your state.)Install applicable octane decalsInstall Correct Nozzle Covers (See Forecourt Notes Page)Install nozzle surround for Amoco Branded DieselInstall Amoco Branded Diesel Actuator ButtonApply vertical grade decal for Branded Amoco DieselApply Handicap decal Apply 10% Ethanol decal (As required by code)Install Amoco Spec Valance (as shown)Apply Riser DecalABCDEFGIJKLMNOPQRBIG RED ROOSTER FLOW2 Northfield Plaza, Ste 211 Northfield, IL 6009318"White RisersRRKQGBFGCJDMNLSPEOAISTDo not use phone while fueling decalTap to pay interfaceUnless prior approval has been given by the Amoco Image Manager: The decals shown in this rendering are the only decals approved by Amoco. The failure to remove existing decals, or the installation of any additional decals will be considered non-compliant with Amoco Brand Standards.Insert and removecard quicklyorThis Sale$GallonsAlternate selection buttonsfor screen prompts aboveSEESCREENABOVE000088880000000088880000000088880000PUSH HERE87MINIMUM OCTANE RATING(R + M)/2 METHOD93PUSH HEREMINIMUM OCTANE RATING(R + M)/2 METHOD89PUSH HEREMINIMUM OCTANE RATING(R + M)/2 METHOD93PUSH HEREMINIMUM OCTANE RATING(R + M)/2 METHOD000088880000$These filler panels will need to be purchased through the dispenser manufacturer, Gilbarco. Amoco Parts will not provide this on the estimate.This is only needed if you are reimaging an existing dispenser and this area is an unapproved dispenser color (Red or Blue).CJOBBER: WORLD FUEL SERVICES ADDRESS: 8333 210TH ST W , LAKEVILLE , MN 55044SVB: 1182600 BUILDINGFASCIA DETAILJOBBER: WORLD FUEL SERVICES SITE LEVEL: B DESIGNER: CONNOR DANIELS REVISON #: JR1ADDRESS: 8333 210TH ST W , LAKEVILLE , MN 55044SVB: 1182600DATE: 01.06.2021The use of ANY color of red is prohibited when the ToGo image is NOT used. If the color red is used on the building without the ToGo treatment, you will need to repaint it before financial settlement can occur. Any prior gasoline brand markings or logos need to be removed.Note: It Is A Requirement That The Building Have A Store Name On It.No AMOCO image will be applied to the building (this includes no T&O/Channel Letter or the word “AMOCO”)YES, this location is receiving a Amoco “Togo” *image (Qty. 0 ). Install: 52" Illuminated Togo Sign 77" Illuminated Togo Sign 112" Illuminated Togo Sign *Note: ToGo sign to be centered over entry door and centered on the fascia above the gradient stripe.YES, this location is receiving a Amoco “Service” image. (Qty. 0 ). Install: 5' Service Decal 5' Service on ACM 5' Illuminated Service Sign 8' Service Decal 8' Service on ACM 8' Illuminated Service Sign 12' Illuminated Service SignExterior Building Walls to be painted BP Retail White (c.01) to be kept naturalBuilding Fascia to be Amoco Retail White (C.01) Paint Fascia Install new ACM Install VinylIs this location is receiving a Red Stripe? Yes No 2 Northfield Plaza, Ste 211 Northfield, IL 60093See Site Notes page for specific paint codes and contact info. *REMOVE ALL UNAPPROVED SIGNAGE FROM DISPENSERS*This is an original concept drawing created by Big Red Rooster Flow, LLC. It is submitted for use in connection with the project being planned for you by BRRFlow. All or any part of this design (except registered trademarks) remains the property of BRRFlow. This drawing is not to scale. For all questions regarding the scope of the project, please contact Emily Wendt 847.971.6981 or The Brand Image Adviser, Larry Rowlands 708.495.5814 Existing painted curbs need to bepainted BP Warm Gray (c.03). If curbing isunpainted, they may remain unpainted.Existing painted islands need to bepainted BP Warm Gray (c.03).If islands areunpainted, they may remain unpainted.For all questions regarding here to locate paints, contact your local Benjamin Moore, Sherwin Williams, or ICI Paints.Benjamin Moore877-626-5676www.benjaminmoore.comSherwin Williams847-330-6262www.sherwin-williams.comICI (now operated by Glidden)888-615-8169 Opt. 2Anchor Paint405-831-9446www.anchorpaint.comWaste ContainerSKU#: 8002866All in One -Front View Side View Overhead SKU#: 8002865All existing trash containers must be removed and replaced with Amoco approved containers.These containers must be Amoco approved colors.Paint BollardsTOP1/3 Amoco Red (c.02); BOTTOM 2/3 Amoco White (c.01). If bollards are stainless steel,they do not need to be painted.Curbs with integrated bollard are to be painted BP Warm Gray (c.03). TOP1/3 of integrated bollard to be painted Amoco Red (c.02). waterairairairvacuumvacuumwaterairvacuumairairwaterairvacuumSCALE: NTSDElevation - Vent Pipes and Light PolesPaint Vent Pipes and Light Poles White.C.L.BA3344SCALE: NTSBFront Elevation - Painted ColumnSCALE: NTSASide Elevation - Painted Column1.5"3"3"Amoco WhiteAmoco WhitePMS 3015refinish existingADA signs withnew colors.Amoco Lt BlueDECALAmoco WhiteAmoco Dk Ble10’-0"from grade3"10’-0"from grade6"10’-0"from gradeADA signs are only placed on the pump closest to the store. Specific pump shall be determined on a per-site basis.NOTE: the light blue stripes of all columnsshould all be at the same level, NOT eachindividual canopy column having the bluestripe 10’ from grade. Installers shouldmeasure the shortest column 10’ from grade, and then measure what is left to the top of thecolumn for the blue decoration. Use thisdimension for the remaining columns2211SCALE: NTSCElevation - Typical undercanopy (startergate)10’-6”2222111110’-6”Notes2 Northfield Plaza, Ste 211 Northfield, IL 60093Printing Concepts: 1. Open your PDF file through Adobe Acrobat and click the "File" tab > "Print…" This will cause a popup to appear on your screen. Locate the "Advanced" button to get to the next step.Select Print as ImageClicking the ‘Advanced' button will cause another popup to appear on your screen, this time you need to click the "Print as Image" button. With this, you are done! Just click "OK" and "Print."This is an original concept drawing created by Big Red Rooster Flow, LLC. It is submitted for use in connection with the project being planned for you by BRRFlow. All or any part of this design (except registered trademarks) remains the property of BRRFlow. This drawing is not to scale. For all questions regarding the scope of the project, please contact Emily Wendt 847.971.6981 or The Brand Image Adviser, Larry Rowlands 708.495.5814SKU #75820499 2 DOUBLE SIDED ISLAND CONVENIENCE CNTRNote: Any deviation form nozzle covers MUST have Amoco approval.Black = DieselGold = Ultimate (premium)Blue = Regularor single-nozzleSilver = Silver (mid-grade)Yelllow = E85(optional for diesel in WI)rver = Silverr(mid-grld = Ultimat(premBlack =DieYelllow =Eptionalel EXT ERIOR PAINT S PECIFIC ATION SAmoco Red- Sherwin Williams, SW6869, "Stop"- Glidden Professional, PPG Amoco Red (Custom Mix)C2BP Warm Gray - Pump Islands- Sherwin Williams, SW7053, "Adaptive Shade"- Glidden Professional, Order #A1860, Spec #40YY 25/074, "Gray Mountain"- Benjamin Moore, 2137-40, "Desert Twilight" - P28 DTM (Gallon)- Anchor Paint, BP Warm Gray - CC3068 (Acrylic), CC3115 (Oil)C3Amoco Gray - Store Wainscot- Sherwin Williams, SW7065, "Argos"- Glidden Professional, PPG1009-4 Gray StoneC4Amoco Light BluePantone Process BlueC (C100 M13 Y0 K0)C5Amoco Dark Blue- Sherwin Williams - SW6965, "Hyper Blue"- Glidden Professional, PPG Amoco Blue (Custom Mix)C6Amoco SilverMatch PMS 877CC710ADA BLU EADA/Handicap Blue~- Glidden Professional , "Handicap Blue", 25524 traffic paint- Sherwin Williams, TM2133, "Setfast Blue", Setfast marking latex- Benjamin Moo re, P58-30, "Handicap Blue", Safety/Zone marking latex- Anchor Paint, BP ADA Blue - CC3074~Handicap Blue paint is used for pavement striping and marking on site (as required).INT ERIOR PAIN TP1WALL PAINT - Eggshell finish- Glidden Professional, Order #A0090, Spec #40YY 79/168, "Candle Wax" - Sherwin Williams, SW6379, "Jersey Cream"- Benjamin Moore, OC-112, "Goldtone" - P28 DTM (Gallon)- Anchor Paint, Candlewax Interior - CC3072 (Eggshell Latex)P4PAINT FOR COFFEE BAC KWALL - Eggshell finish- Sherwin Williams, SW6866, "Heartthrob"P5PAINT FOR METAL CABINETRY - Eggshell finish- Glidden Professional, Order #A0731, "Dakota Land"P2PAINT FOR DROP CEILING & DOORS - Eggshell finish- Glidden Professional, Order #A1807, Spec #30YY 62/127, " Water Chestnut"- Sherwin Williams, SW6141, "Softer Tan"- Benjamin Moore, OC-11, "Clay Beige" - P28 DTM (Gallon)- Anchor Paint, Water Chestnut Interior - CC3073 (Eggshell Latex)P3PAINT FOR to go BACKWALL - Eggshell finish- Glidden Professional, Order #A0717, Spec #20YY 65/285, "Indian Corn"- Sherwin Williams, SW6380, "Humble Gold"- Benjamin Moore, 2160-50, "Oklahoma Wheat" - P28 DTM (Gallon)- Anchor Paint, Dark Pearl Interior - CC3070 (Eggshell Latex)White (Canopy Deck, Canopy Columns, Sto re Exterior)- Glidden Professional, Order #A0128, Spec #50GY 83/010, " White Wing"- Sherwin Williams, SW7006, "Extra White"- Benjamin Moore, OC-67, "Ice Mist" - P28 DTM (Gallon)- Anchor Paint, BP White - 4900 (Acrylic), 900 (Oil)C12 Northfield Plaza, Ste 211 Northfield, IL 60093This is an original concept drawing created by Big Red Rooster Flow, LLC. It is submitted for use in connection with the project being planned for you by BRRFlow. All or any part of this design (except registered trademarks) remains the property of BRRFlow. This drawing is not to scale. For all questions regarding the scope of the project, please contact Emily Wendt 847.971.6981 or The Brand Image Adviser, Larry Rowlands 708.495.5814