Loading...
HomeMy WebLinkAboutLA192729 - 17873 Graphite Lane Permit PackRESIDENTIAL BUILDING PERMIT APPLICATION CITY OF LAKEVILLE BUILDING INSPECTIONS DEPARTMENT 20195 HOLYOKE AVENUE LAKEVILLE, MN 55044 952-985-4440 Office Use Only __________________ Permit Number ___________________ Received By ___________________ Date Received ___________________ Fee Total SITE ADDRESS: MAILING ADDRESS: CITY: STATE: ZIP: JOB DESCRIPTION:__________________________________ MASTER PLAN: (Number or Address)____________________ LIST OTHER STRUCTURES ON PROPERTY:_______________________________________________________________ ESTIMATED VALUATION: PROPOSED START DATE: END DATE: (New Residential Only): LEGAL DESCRIPTION: LOT: _____ BLOCK: _____ SUBDIVISION: APPLICANT IS: RESIDENT OWNER CONTRACTOR EMAIL NEW MODEL HOME: YES NO (IF YES – ADMINISTRATIVE PERMIT REQUIRED) PLEASE FILL OUT THE FOLLOWING COMPLETELY (All Contractor information must be as listed on State License) RESIDENT OWNER NAME:_______________________________________________________________________________ HOME PHONE #:_____________________________ CELL PHONE:___________________________ GENERAL CONTRACTOR Homeowner Contractor CONTRACTOR:_______________________________________________________________________ LICENSE #:BC______________ LEAD CERTIFICATE#_______________ (PRE 1978 STRUCTURE) OFFICE PHONE #:_____________________________ CELL PHONE:___________________________ ADDRESS:____________________________ CITY:________________ ST:______ ZIP:____________ PLUMBING WORK Homeowner Contractor CONTRACTOR:__________________________________________LICENSE #: PM______________ OFFICE PHONE #:_____________________________ CELL PHONE:___________________________ ADDRESS:____________________________ CITY:________________ ST:______ ZIP:____________ MECHANICAL WORK Homeowner Contractor CONTRACTOR:________________________________________ _______________________________ OFFICE PHONE #:_____________________________ CELL PHONE:___________________________ ADDRESS:____________________________ CITY:________________ ST:______ ZIP:____________ BOND #:_______________________________________ EXPIRATION DATE____________________ SEWER/WATER CONTRACTOR New Construction Only NAME:________________________________________________ ______________________________ HOME PHONE _____________________________ CELL PHONE:______________________________ BOND #:_______________________________________ EXPIRATION DATE____________________ INTEREST EARNINGS ON THE ESCROW ACCOUNTS, IF ANY, ARE RETAINED BY THE CITY TO OFFSET THE ADMINISTRATIVE COSTS ASSOCIATED WITH PROCESSING THE ESCROW APPLICATION AND REFUND. I HEREBY APPLY FOR A BUILDING PERMIT AND I ACKNOWLEDGE THAT THE INFORMATION ABOVE IS COMPLETE AND ACCURATE; THAT THE WORK WILL BE IN CONFORMANCE WITH THE ORDINANCES AND CODES OF THE CITY AND WITH THE STATE BUILDING CODE, THAT I UNDERSTAND THIS IS NOT A PERMIT AND WORK IS NOT TO START WITHOUT A PERMIT AND THAT THE WORK WILL BE IN ACCORDANCE WITH THE APPROVED PLAN. NAME OF APPLICANT (Please Print)DATE APPLICANT’S SIGNATURE: www.lakevillemn.gov Nick Reimler RESIDENTIAL BUILDING PERMIT APPLICATION PAGE 2 OFFICE USE ONLY BUILDING PERMIT TYPE REQUIRED INSPECTIONS SINGLE FAMILY DWELLING BUILDING DUPLEX AS BUILT TOWNHOUSE UNITS BUILDING FINAL DETACHED TOWN HOUSE UNIT DECK FOOTING CONDO FIREPLACE ACESSORY BUILDING FOOTING REROOF FOUNDATION RESIDE FRAMING PORCH FRAMING GARAGES INSULATION RES ADDN/REPAIR/RMDL DECK PORCH GARAGES LATH LOWER LEVEL FINISH LOWER LEVEL FINAL ADDITION OTHER FOUNDATION ONLY PORCH FOOTING MISCELLANEOUS POURED WALL DEMO SEPTIC TANK REMOVAL MOVED SITE MECHANICAL CITY BUILDING VALUATION: $AIR TEST FINAL BUILDING PERMIT FEES ROUGH-IN $PERMIT FEE PLUMBING $PLAN CHECK FINAL $SURCHARGE ROUGH-IN $METRO SAC METER SIZE $CITY WATER HOOKUP UNIT PRESSURE REDUCING VALVE $CITY SEWER HOOKUP UNIT SEWER/WATER $LANDSCAPE ESCROW SEWER/WATER $TREE ESCROW FINAL $MISC ESCROW STREET DRAINTILE $PLUMBING BUILDING INFORMATION $MECHANICAL TYPE OF CONSTRUCTION $SEWER WATER ZONING $OTHER CODE EDITION $TOTAL FIRE SUPPRESSION SYSTEM OCCUPANCY GROUP APPROVED BY: BUILDING INSPECTOR: Date: PLUMBING/MECHANICAL INSPECTOR: Date: COMMENTS: 20195 Holyoke Avenue, Lakeville, MN 55044 952-985-4400  952-985-4499 fax www.lakevillemn.gov Sewer & Water Tie Card Address:________________________________________ Contractor:______________________________________ Permit Number:__________________________________ Final Date:________________ Street Drain-Tile:______ Size of Water Service: 1” Comments: AIRTEST SANITARY OVER 20’/2 FITTINGS THIS CARD MUST BE COMPLETED AND ON-SITE AT TIME OF SEWER & WATER INSPECTION 1 7SCALE: 1/4" = 1'-0" FRONT ELEVATION GENERAL NOTES: 1. ALL DOOR AND WINDOW HEADERS TO BE S.P.F. #2 OR BETTER, SEE PLANS FOR SIZES. 2. HOUSE TO BE BUILT PER CURRENT I.R.C. CODES. 3. VERIFY GRADES AND ADJUST FOUNDATION/FOOTING STEPS AS NEEDED. 4. SEE PLANS FOR CEILING HEIGHTS 5. 4' HIGH POURED FDN. WALLS STD. 6. FLOOR PLAN DIMENSIONS ARE TO FACE OF FRAMING AND FOUNDATION. 7. ALL TRADES & SUPPLIERS TO REVIEW & VERIFY INFORMATION PERTINENT TO THEIR WORK AND NOTIFY CONST. OF ANY DISCREPANCIES PRIOR TO CONSTRUCTION. 8. NOTED CABINET SIZES ARE +/- AND TO BE FIELD VERIFIED. 9. TRADES TO VERIFY BASE AND TRIM SIZE PRIOR TO CONSTRUCTION. 10. ALL WALLS MORE THAN 10' H. TO BE S.P.F. #2 OR BETTER. 11. EXTERIOR ELEVATIONS ARE CONCEPTUAL ONLY: HOME SITE, FILL AND TOPOGRAPHY WILL DICTATE ACTUAL GRADES AND MAY VARY FROM THOSE SHOWN ON THE PLAN. 12. NOTE: SUBFLOOR JOINTS SHALL BE STAGGERED FROM FLOOR TRUSS OR JOIST JOINTS OF SHEET 07-00-BUYERPROJECT # BUYER S/O BUYER S/O REVISIONS: STARTED: AGENT:X XLOT 9, BLOCK 12, SUMMERS CREEK17873 GRAPHITE LN., LAKEVILLE, MN"SONOMA" 1640 VILLA HOMEMARK ELLIOTT HOMES3-12-21 SELECT 4-22-2021 PERMIT SCALE: 1/8" = 1'-0" ROOF PLAN SEE ROOF PLAN FOR ROOF PITCHES AND OVERHANGS 25'-9"CONC. PORCH 4" TRIM TYP. 6:12 8'-2"T.O. 3648 FX ALUM. SOFFIT & FASCIA 30 YR. ARCH. ASPHALT SHINGLES 6" TRIM 14" LP COLUMNLP PANEL 9'-1 1/8"T.O. SUBFLR. T.O. PLATE 1'-8 1/4"T.O. FDN.9'-1 1/8"@ GARAGE T.O. PLATE 12 12 12 12 (BLACKENED)1'-0"6" TRIM12" CANT. 10" TRIM C/L T.O. FDN.11"@ DORMERT.O. PLATE 10'-0"FP CHASE 24"x60" FALSE 6" TRIMLP SIDING PER SPECS STONE CAP STONE TOTAL: 84.77 SQ. FT. (26.97%) TOTAL SQ. FT.: 314.26 MATERIAL CALCULATIONS: FRONT ELEV. LP LAP SIDING TOTAL: 31.28 SQ. FT. (9.95%) LP B/B TOTAL: 118.29 SQ. FT. (37.57%) LP TRIM / PANEL: 79.92 SQ. FT. (25.51%) STONE TOTAL: 107.24 SQ. FT. (8.7%) TOTAL SQ. FT.: 1,833.77 MATERIAL CALCULATIONS: ALL ELEV. LP LAP SIDING TOTAL: 1,179.50 SQ. FT. (36.9%) LP B/B TOTAL: 203.86 SQ. FT. (3.5%) LP TRIM / PANEL: 343.17 SQ. FT. (16.9%) LP SMARTSIDE BD. & BATTEN SIDING 12 12 12 12 12 12 12 12 6:12 LP SMARTSIDE BD. & BATTEN SIDING 6" TRIM T.O. PLATE 3.25 +/-:12 10'-3" 6'-7" 6" TRIM SADDLENOTE: SEE ROOF TRUSS LAYOUT FOR TRUSS DIRECTION AND GIRDER LOCATIONS PROVIDED BY MANUFACTURER PROVIDE ATTIC VENTILATION EQUAL TO 1/150th ATTIC AREA. IF 50% OR MORE IS PROVIDED IN UPPER PORTION OF THE ROOF AND REMAINDER IS PROVIDED IN SOFFIT VENTS, IT MAY BE REDUCED TO 1/300th ATTIC AREA. ICE AND WATER SHIELD 6'-0" IN FROM EAVES 1'-6" ON EACH SIDE OF VALLEY WHERE WALLS MEET ROOF ICE & WATER SHIELD SHOULD RUN UP WALL 1'-6" AND OUT FROM WALL 1'-6" NOTE: NOTE: NOTE: 1'-6"2'-0"RIDGERIDGE 2'-0"1'-6"6:126:1212:12 2'-0"1'-0"4'-11"1'-6" 1'-6"2'-0"1'-0" 12:12 RIDGE12:12 12:12 6:121'-0"12:12 12:12 12:12 12:12 6:123.25:121'-0"1'-6" 12:12 12:12 1'-0"1'-6"1'-6"4'-0"Concept Approval ONLY Subject to Field Inspection Inspector Date 2020 MN Bldg Code 07/13/2021dmathews EXTERIOR ELEVATIONS ARE CONCEPTUAL ONLY: HOME SITE, FILL AND TOPOGRAPHY WILL DICTATE ACTUAL GRADES AND MAY VARY FROM THOSE SHOWN ON THE PLAN.2 7 07-00-BUYERPROJECT # BUYER S/O BUYER S/O REVISIONS: STARTED: AGENT:X XLOT 9, BLOCK 12, SUMMERS CREEK17873 GRAPHITE LN., LAKEVILLE, MN"SONOMA" 1640 VILLA HOMEMARK ELLIOTT HOMES3-12-21 SELECT 4-22-2021 PERMIT OF SHEET SIDE ELEVATION SCALE: 3/16" = 1'-0" REAR ELEVATION SIDE ELEVATION SCALE: 3/16" = 1'-0" SCALE: 3/16" = 1'-0" @ GARAGE 9'-1 1/8"T.O. FDN.A/C UNIT T.O. PLATE 9'-1 1/8"T.O. SUBFLR. T.O. FDN.1'-8 1/4"12 6 12 6 T.O. PLATE ALUM. SOFFIT & FASCIA PER SPECS SEE ROOF PLAN FOR PITCHES AND OVERHANGS 12:12 12:12 12:12 10" TRIM ROOF LINE BEYOND 12:12 12:12 LP SIDING 12 3.25 4" LP TRIM @ WDWS. & DOORS TYP. 10" TRIM LP PANEL 12" CANT. FP VENT STONE4" LP TRIM @ WDWS. & DOORS TYP. WHERE INDICATED T.O. PLATE 9'-1 1/8"T.O. SUBFLR. T.O. FDN.1'-8 1/4"12 6 12 6 ALUM. SOFFIT & FASCIAPER SPECS SEE ROOF PLAN FOR PITCHES AND OVERHANGS 12:12 12:1212:12 12:12 10" TRIM LP SIDING 12 3.25 ROOF LINE BEYOND LP SIDING PER SPECS EGRESS SEE ROOF PLAN FOR PITCHES AND OVERHANGS ALUM. SOFFIT & FASCIA 6:12 LP SIDING PER SPECS 12 12 12 12 12 1212 12 T.O. PLATE 9'-1 1/8"T.O. SUBFLR. T.O. FDN.1'-8 1/4"4" LP TRIM @ WDWS. & DOORS TYP. 10" TRIM 10" TRIM EGRESS 6:12 12" CANT. Secure door closed until deck is constructed with a separate permit. SCALE: 3/16" = 1'-0" FOUNDATION PLAN 3 7 07-00-BUYERPROJECT # BUYER S/O BUYER S/O REVISIONS: STARTED: AGENT:X XLOT 9, BLOCK 12, SUMMERS CREEK17873 GRAPHITE LN., LAKEVILLE, MN"SONOMA" 1640 VILLA HOMEMARK ELLIOTT HOMES3-12-21 SELECT 4-22-2021 PERMIT OF SHEET A/C UNIT w/ BRACKET FURN F.D. WH MECH. 3068 2668 BDRM. #3 FAMILY ROOM L.L. BATH 36" V.CONC. H.B. H.B. 2" LEDGE TYP. TO PROVIDE ADD'L.SUPPORT FOR FILL FOR SLAB TYP. FND @ HOUSE / GARAGE 10" POURED CONC. W/ 4" LEDGE INSIDE 20X8 CONC. FTG. 2" FOAM SUMP H20 4" LEDGE 2" FOAM TYP. FND @ STOOP 12" POURED CONC. W/ 4" LEDGE INSIDE 20X8 CONC. FTG. UNEXCAVATED 2" NOTE: NO DRYWALL @ CLG. REQUIRED IN THIS AREA - FIRE BLOCK @ PERIMETER OF OPNG. (80 SQ. FT. MAX.) 6"2" RADON VENT TO TERMINATE IN SUMP BASKET 6" 4" 10" GARAGE/HOUSE COMMON WALL 2x8 TREATED SILL OVERHANG FDN. 2'' GARAGE SLAB 2'' RIGID INSUL. MAIN FLR SEE FIRST FLOOR FOR GARAGE DOOR SIZE FOR M.O. NOTE: 4" LEDGE 6"2"CARPET CARPET 3 1/2'' CONC. FLOOR TYP. FND @ HOUSE 8" POURED CONC (9'-0" H.) 20X8 FTG REBAR PER CODE TYP. FND @ BRG. WALL 2x4 STUDS 16" O.C. 16X8 FTG REBAR PER CODE 4" CONC. CURB KITCHEN ISLAND ABV. FLR. TRUSS CO. 2 4 6 8 18" FLR. TRUSSES19.2" O.C. SPACING2-2x10 (DR) (11'-3"x12'-7") (25'-6"x12'-6") RADON VENT NOTE: EXTERIOR HOUSE AND GARAGE/HOUSE COMMON FDN. WALLS TO BE HELD 2'' IN. DIMENSIONS SHOWN ARE TO FACE OF 2'' EXTERIOR RIGID INSULATION & FRAMING ABOVE TO BE 5000 PSI CONC.NOTE: ALL FOOTINGS 2'' MIN. 2x8 TREATED SILL-OVERHANGFDN. 1 1/2''8" 2" TYP. SIDE WALL DETAIL FOUND. HELD IN 2" FOR INSULATION NOTE: (TYP.)2"2"2"2" 9'-0" POURED FDN. APPROX. 1,678 NET SQ. FT. FILL FOR SLAB UP 17 R (10" T., 7-3/4" MAX. R.) 14'-6"12'-0"58'-0"6'-0"52'-0"66'-0"4'-0"29'-0"33'-0"10'-0"14'-0"10'-6 1/2"10'-0"12'-0"2'-0"19'-0"40'-0" 19'-0"21'-0" 19'-5 1/2" & HOUSE/PORCH 10'-9"10'-3"18" FLR. TRUSSES19.2" O.C. SPACINGFOUND. HELD IN 2" FOR INSULATION NOTE: (TYP.) 20682x10 TRTD. JOISTS16" O.C. SPACING3-2x10 TRTD. (FL) SMOKECM / 12" CANT. ABV.2x6 BRG. 2x6 BRG. 10'-0" H. FOUND. WALL @ FRONT OF HOME NOTE: 10'-0" H. FOUND. WALL @ FRONT OF HOME NOTE: w/ TOP HUNG TRUSSES w/ TOP HUNG TRUSSES 10'-0" H. FOUND. WALL @ FRONT OF HOME NOTE: w/ TOP HUNG TRUSSES 10'-2 1/2"3'-10 3/4"6'-8 3/4" 13'-1"3'-2"13'-9"10'-0"3'-9"3'-10"6'-4"19'-8 1/2"9'-2 1/2"19'-3"7'-0 1/2"12'-5" 30"x30" CONC. PAD FTG. 6x6 COL. 16" DIA. FROST FOOTING (60" D.) 6x6 TRTD. COL. 2-2x10 (FL) (2) TR 2-9 1/2" LSL (DR) 2 4 6 8 3'-2"2'-8"4'-0"3'-4 1/4"8'-0"9'-5 1/2"1'-5 1/4"20'-0" 40'-0" 6'-9"6'-9" 5'-0"4'-0"CONC. WDW WELL 3042 CSMT 2-9 1/2" LSL 3'-8"4'-11" 26'-6"13'-6" 2668STORAGE CONC. 2668OFFICE / BDRM. #4 CARPET (11'-0"x10'-2")5'-0"4'-0"CONC. WDW WELL3042 CSMT2-9 1/2" LSL3'-8"42" GAS F.P.2'-0" R&SH 2 - 2068 CLST. CARPET 5'-0"P.H. TR LVP FLR.(4) SH. LINENCARPET CARPET CARPET BAR SINK EXCH.AIR SD SMOKECM / TYP. FND @ HOUSE 8" POURED CONC (9'-0" H.) 20X8 FTG REBAR PER CODE WS FIBRGLS. 60x32 SHWR. UNIT HUMIDIFIER* APRILAIRE NOTE: OPNG. FOR NOTE: UC REFR.6'-0 1/4"6'-9"3/0 x 7/0 SRO3'-2"4'-0"8'-5"3'-10"2'-5"22'-9"5'-0"2'-10"TB8'-6"2'-2"(3)2x10 #1 SP or (3)2x12 #2 SP Provide footing below bearing wall. UFER Ground -Provide 20' Rebar in footing and stub up near electrical service panel. BWPs Above Smoke SCALE: 3/16" = 1'-0" MAIN FLOOR PLAN 4 7 07-00-BUYERPROJECT # BUYER S/O BUYER S/O REVISIONS: STARTED: AGENT:X XLOT 9, BLOCK 12, SUMMERS CREEK17873 GRAPHITE LN., LAKEVILLE, MN"SONOMA" 1640 VILLA HOMEMARK ELLIOTT HOMES3-12-21 SELECT 4-22-2021 PERMIT 6-7-2021 REV. #1 OF SHEET P.H.TBTR DW GAS RANGEHOODVENT ABV. FLUSH OH. LNDRY. DRYER WASHER 9' CLG. / LVP WIRE SH. (VENT TO OUTSIDE)NOTE: - STD. BASE & CASING TO BE PRINCETON - 1/2 WALL w/ WD. CAP & INVERTED CASING NOTE: 2X6 EXT. WALLS U.N.O. 2X4 INT. WALLS U.N.O. - 42" UPPER CABINETS DOOR ROUGH OPENINGS: 83" HEIGHT 82" OVER VINYL CERAMIC TILE & WOOD 82" OVER CARPET SRO = SHEET ROCKED OPNG BIFOLD DOORS: PREHUNG UNITS: 2" WIDER THAN DOOR (EXAMPLE: 2668 ) 1 3/8" WIDER THAN DOOR FINISH SIZE NOTED ON PLAN CO = CASED OPENING ( WOOD ) (EXAMPLE: 2668 ) FINISH SIZE NOTED ON PLAN RO. 1 1/2" WIDER, 83" HIGH R.O. 1" WIDER, 83" HIGH PER SPECS DRIVEWAY NOTE: REF. KITCHEN 9' CLG. / LVP13'-2" x 12'-6" (155 SQ. FT.) 3-16" LVL GREAT ROOM 9' CLG. / LVP FLR.42" GAS F.P.12'-8" x 15'-0" (196 SQ. FT.) / LVP 42" W. CONC. SIDEWALK FBRGLS. BASE 60x36 SHWR. C.T. WALLS 5'-0"21068FOYER 9' CLG. / LVP 5'-10" x 11'-8" (69 SQ. FT.) PORCH CONC. / BEADBD. CLG. O. BATH 9' CLG. / VIN. 2x6 WALLS U.N.O. 4" SLOPED CONC. GARAGE CEIL. TO BE 5/8" TYPE 'X' GYP. BD. WALLS TO BE 1/2" GYP.SHEATHING. ALL WALLS & CEILINGS TO HAVE ONE COAT FIRETAPE GARAGE 6'x8' PATIO DR. 16'x7' O.H.D. R.O. 16'-1" FRAMING O. CLST 8' CLG. / CARPET 36" VAN. BATH BEDROOM #2 / OFFICE 26683648 SH @ 8'9' CLG. / LVP FLR. w/ WD. CAPMANUF. TRUSSES24 O.C.(12'-3"x12'-0") EXTERIOR FLOOR PLAN DIMENSIONS ARE TO OUTSIDE OF SHEATHING, INTERIOR DIMENSIONS ARE TO FRAMING. NOTE: ALL DRS/ WIN.'S REQUIRE 4" ON SIDES FOR CASING NOTE: 2X6 EXT. WALLS U.N.O. 2X4 INT. WALLS U.N.O. HEADER SPANS: UP TO 4'-11'' = 1 TRIMMER 5'-0'' AND BIGGER = 2 TRIMMERS UNLESS NOTED OTHERWISE INDICATES LOCATION OF SOLID BRG. (150 SQ. FT.) OWNERS BDRM. BOX VAULT / CARPET (12'-6"x13'-7") (173 SQ. FT.) SMOKECM / SD 2 - 4072 SH @ 8' DN 17 R (10" T., 7-3/4" MAX. R.) 8/0 H. SOFFIT MANUF. TRUSSES24 O.C.ATTICACCESSAPPROX. 553 SQ. FT. MUDRM. 9' CLG. / LVP APPROX. 9'-0'' CLG. @ MAIN LEVEL APPROX. 1,678 SQ. FT. 3 0 6 8 M T L .3080 MTL.2468R&SH R&SH9' CLG. / LVP FLR.9' CLG. 8' SOFFIT 28682668R&SHR&SH36" VAN. LIN.CAB. 3068BASE CAB.w/ LTUB. 2 - 4072 SH @ 8'30" VAN. DINING 9' CLG. / LVP FLR.11'-0" x 14'-10" (168 SQ. FT.) 3672 SH @ 8'3672 SH @ 8'4872 PICT. @ 8' 3-SEASON PORCH DECKING PER SPECS MANUF. TRUSSES24 O.C.40'-0" 14'-6"12'-0" 8'-6"11'-10"6'-2" 6'-9"68'-0"6'-0"52'-0"12'-8"4'-10"5'-8"12'-8 3/4"7"4'-11"5'-2 1/2"5'-4 3/4"7'-8 1/4"5'-0 1/2"68'-0"4'-0"29'-0"33'-0"6'-9 1/2"14'-4"3'-2"10'-6 1/2"10'-0"12'-0"2'-0"19'-0"40'-0" 19'-0"21'-0" 13'-0"6'-0" 6'-7"6'-5" 10'-9"10'-3" RADON VENT SD SMOKECM / 2'-10 1/4"2'-4 1/2"2424 PICT. @ 8'2424 PICT. @ 8'2'-6 1/2"2'-6 1/2" 3068 BARN DR.2448 SH @ 8'5'-0"WD. STEP 3'-11 1/4"6'-0 3/4" 2'-0" 16'-10 1/2" 2'-7 1/2"2'-4"4'-0"5'-0"12" CANT.6'-4"8'-0"3'-9"3'-9"3'-0"3'-0"2-2x102-2x102-2x102-2x104 1/2"4 1/2"MANUF. TRUSSES24 O.C.FP CHASEFALSE 2-9 1/2" LSL (CONT.)2-9 1/2" LSL 2-2x10 (2) TR 2-2x10 P.H. TR 3068 PKT.3'-6"6'-0"3'-6"5'-0"13'-6" 6'-9" 26'-6"10'-0"21068TR R&SH R&SH 1/2 WALL R&SHR&SH 26689'-7 1/2"9'-6 1/2"2668 PANTRY 9' CLG. / LVP (5) SH. 9' CLG. / LVP 2468R&SH2/10 x 6/7 SRO6'-0 3/4"4'-3"2'-10 1/2"6'-8 3/4"7"2'-5"4'-8 1/2"5'-10"12'-2 3/4"7"6'-2 1/4"5'-7 3/4"2'-5 1/2"5'-7"4'-9 1/4" 1'-0" 11"5'-2"5'-10"2'-1"2'-5 1/4"2x65'-11 1/4" 3'-9" 8'-4" GIRDER TRUSS (3) 2x6 (3) 2x6 MANUF. TRUSSES 24 O.C. 9 1/2"7'-10 1/2"2'-3"3-9 1/2" LVL 2-2x10 60x32FBRGLS.SHWR. UNITPA 7"5'-0"5'-8"2'-10" 14" LP COL. 4"12'-0"2-7 1/4" LSL (DR)4"LP SOFFIT 4"4"7'-4" 2-7 1/4" LSL (DR)2-7 1/4" LSL (DR) F.D.(VERIFY LOCATION) INSTALL SHWR. NOTE: HEAD 4-6" HIGHER THAN STD. HT. * INSULATE WALLS& CLG. AT GARAGE NOTE: PROVIDE WIRING & GAS (FIELD VERIFY LOCATION)FOR FUT. HEATER 84" H. RADON VENT 2'-0" TYP. 8' CLG. 9' CLG. GIRDER TRUSS (3) 2x6 (3) 2x6(MATCH DR. HT.)2-11 7/8" LSL (FULL LENGTH)5460 SLIDER (MATCH DR. HT.) 2-2x10 9660 SLIDER 3'-1"4'-11"3068 MTL.F U L L L I T E 2-7 1/4" LSL (DR) SMOKE CM / 2'-0"TB 1 Temper Temper PFH PFH 6 8 8 5 7 07-00-BUYERPROJECT # BUYER S/O BUYER S/O REVISIONS: STARTED: AGENT:X XLOT 9, BLOCK 12, SUMMERS CREEK17873 GRAPHITE LN., LAKEVILLE, MN"SONOMA" 1640 VILLA HOMEMARK ELLIOTT HOMES3-12-21 SELECT 4-22-2021 PERMIT OF SHEET SCALE: 1/4" = 1'-0" SECTION1 5 N.T.S. HOUSE / DECK CONNECTION DETAIL4 5 3/4" T & G FLOOR NOTE: SUBFLOOR JOINTS SHALL BESTAGGERED FROM FLOOR TRUSS ORJOIST JOINTS R=0.61 R=49.00 R=50.25 R=0.58 R=.061 TOTAL TRUSSES - 24" OC BLOWN INSULATION INTERIOR AIR FILM VAPOR BARRIER 15/32" OSB SHTG. 15# FELT EXTERIOR AIR FILM ICE AND SNOW SHIELD 30 YR. ARCH. ASPHALT SHINGLES 5/8" GYP BD ALUM. SOFFIT & FASCIA 1/2" GYP BD INTERIOR AIR FILM TOTAL SIDING PER SPECS 2x6 STUDS 16" OC R=1.06 R= R= R=21.00 R=0.45 R=0.17 R=23.36 VAPOR BARRIER FULL WALL BATT INSUL. EXTERIOR AIR FILM R=0.68 7/16" OSB SHTG. 8" AGGREGATE6 MIL POLY. LAP SEAMS 12"10"HEEL HT.1/2" GYP. SHEATHING ON GARAGE WALLS 5/8" TYPE 'X' GYP. BD. ON GARAGE CEILS. 18" FLOOR TRUSSES9'-1 1/8"T.O. SUBFLR. T.O. PLATE TRUSSES @ 24" O.C. (DESIGNED BY MFR) 6 12 R-49 INSUL.10'-0"GARAGE 4" SLOPED CONC. W/ REBAR PER ENGINEERS REPORT 10'-0" POURED WALL DRAIN TILE 10" POURED WALL R-5 INSUL. ATINTERIOR FOUND.9'-9 1/8"O. BATH OWNERS BDRM. 20x8 CONC. FTG.16x8 CONC. FTG. 16x8 CONC. FTG. SPRAY FOAM RIM 8'-10" +/-FOUND. HELD IN 2" FOR INSULATION TYP. NOTE: (INSUL. FLUSH w/ SHTG.) CANT. 2x8 SILL PLT. 1-1/2"3 1/2" CONC. FLOOR 8 1/4"6"HEEL HT.6 12 8 1/4"2'-11" NOTE: TOP HUNG TRUSSES AT FRONT OF HOME (9'-4" H. FDN. WALL) SPRAY FOAM RIM 4"12"6 3/4" +/-1'-8 1/4"20x8 CONC. FTG. T.O. FOUND.9'-0"R-5 THERMAX AT INTERIOR FOUND. AS REQUIRED BDRM. #3 L.L. BATHCLST. 6 12 2'-0"12"GIRDER GIRDER 27'-0" JOIST W/ 2-3/8" LAG BOLTS ICE & WATER EXTENDS 5" UP SHEATING UNDER INSTALL TOP OF LEDGER 3 5/8" BELOW TOP OF 3/4" SUBFLOOR (THIS ALLOWS 5/4 X 4 THRESHOLD AT DOOR) HANGER TREATED 2X10 LEDGER RUN HOUSE WRAP BEHIND LEDGER (LEAVE 6" TAIL @ TOP, BOTTOM, & SIDES) HOUSEWRAP @ 24" O.C. -OR- EMBED 2" MIN.8 INCHES O.C. MAX OR EQUAL,W/ "LEDERLOK" FASTENERS CONT. 2X4 RIBBON SPRAY FOAM INSUL. R-21 MIN.RIM BOARD TREATED JOIST JOISTRIM BD.SKIRT 1" HOUSE END OF DECK HOUSE LATERAL LOAD SIMPSON DTT1Z DECK-TO CONNECTOR - (4) PER DECK OR 8-10DX1 1/2" NAILS 6-SD#9X1 1/2" SCREWS HDG WASHER OR SDWH 3/8" HDG LAG SCREW WITH TIMBER-HEX HDG SCREW (SHOWN) INTO TOP PLATE, STUDS, OR HEADER CONT. 2X8 RIBBON DRAIN TILE 3/4" WASHED ROCK CONTINUOUS UNDER SLAB0'-16" SILT FABRIC FOUNDATION WALL CONC. FTG. 4" DRAIN TILE 2 SCALE: NO SCALE5 TOP OF FDN.RIM DETAIL3 SCALE: NO SCALE5 2" RIGID INSULATION R-10 w/ WATCHDOG WATERPROOF COATING AROUND HOUSE FOUND. 2" RIGID INSULATION R-10 w/ WATCHDOG WATERPROOF COATING AROUND HOUSE FOUND. 2x8 TRTD. SILL SHEATHING FLUSH WITH INSULATION NOTE: FOUNDATION TO BE HELD IN 2" FROM SHEATHING & OUTSIDE DIMENSIONS. CANTED 1-1/2" 6 7 07-00-BUYERPROJECT # BUYER S/O BUYER S/O REVISIONS: STARTED: AGENT:X XLOT 9, BLOCK 12, SUMMERS CREEK17873 GRAPHITE LN., LAKEVILLE, MN"SONOMA" 1640 VILLA HOMEMARK ELLIOTT HOMES3-12-21 SELECT 4-22-2021 PERMIT OF SHEET SCALE: 1/4" = 1'-0" SECTION1 6 N.T.S. PORTAL FRAME DETAIL2 6 N.T.S. RADON DETAIL3 6 SIMPSON STRONG TIE Ab46z HEADER HURRICANE CLIP ATTACHED TO COLUMN & BEAM 11 7/8" OSB STRINGER W/ 2X4 BRACING 10 1/2" BULLNOSE LSL TREAD1X8 PINE S4S RISER NOTE: MAX RISE= 7 3/4" MIN. RUN= 10" 6'-8" CLEAR HEADROOM BATH BEDROOM #2 / OFFICEGREAT RM. 3/4" T & G FLOOR NOTE: SUBFLOOR JOINTS SHALL BESTAGGERED FROM FLOOR TRUSS ORJOIST JOINTS ALUM. SOFFIT & FASCIA 8" AGGREGATE6 MIL POLY. LAP SEAMS 12" 18" FLOOR TRUSSES9'-1 1/8"T.O. SUBFLR. T.O. PLATE TRUSSES @ 24" O.C. (DESIGNED BY MFR) R-49 INSUL.10'-0"W/ REBAR PERENGINEERS REPORT 9'-4" POURED WALL DRAIN TILE 10" POURED WALL R-5 INSUL. ATINTERIOR FOUND. 20x8 CONC. FTG.16x8 CONC. FTG. SPRAY FOAM RIM 8'-10" +/-FOUND. HELD IN 2" FOR INSULATION TYP. NOTE: (INSUL. FLUSH w/ SHTG.) CANT. 2x8 SILL PLT. 1-1/2" 3 1/2" CONC. FLOOR 2" RIGID INSULATIONR-10 w/ WATCHDOG WATERPROOF COATING AROUND HOUSE FOUND. PORCH10"HEEL HT.6 12 MECH. / STORAGEFAMILY ROOM 6 12 KITCHEN 8 1/4"4x4 TRTD. COL. 3 5 4" LEDGE NOTE: TOP HUNG TRUSSES AT FRONT OF HOME (9'-4" H. FDN. WALL) CONC. STOOP6 3/4" +/-4"SPRAY FOAM RIM1'-8 1/4"20x8 CONC. FTG. T.O. FOUND.9'-0"2 5 R-5 THERMAX AT INTERIOR FOUND. AS REQUIRED 17R4 1/2"27'-0" 6x6 TRTD. 14" LP COL. 1'-2"4'-9" 3.25 12 3'-0" OFFICE / BDRM. #4 SIMPSON STHD14 HOLD DOWN SIMPSON LSTA36 STRAP ON INSIDE FACE OF WALL 5/8" ANCHOR BOLT 1/2" OSB SHEATHING HEADER- SEE PLAN FOR SIZE FASTEN SHEATHING TO HEADER WITH 8d COMMON ORGALVANIZED BOX NAILS IN 3" GRID PATTERN ASSHOWN, AND 3" O.C. IN ALL FRAMING MEMBERS TYP. SHEATHING SPLICE (IF NEEDED) MUST BE LOCATED WITH-IN 24" OF THE MID HEIGHTOF THE DOOR OPENING. PROVIDE 2-2X6BLOCKING BEHIND SPLICE FASTEN TOP PLATE TO HEADER WITH2 ROWS OF 16d SINKER NAILS 3" O.C. BLOCK BACK SIDE OF HEADER FLUSH WITH STUDSAT STRAP LOCATIONS UNEXCAVATED SOIL ALL SLABS WILL HAVE A MIN. 4" CLEAN AGGREGATE, COVERED BY 6 MIL POLY. THIS POLY WILL HAVE 12" LAP AT ALL SEAMS. ALL TEARS OR PUNCTURES WILL BE SEALED OR COVERED BY POLY. ALL OPENINGS WILL BESEALED USING POLYURETHANE CAULK OR ELASTOMERIC SEALANT AT ALL OPNGS. AN INSTALLED 3" GASTIGHT PVC PIPE WILL BE CONNECTED TO THE DRAIN TILE SYSTEM. A "T" FITTING WILL BE INSTALLED WITH 10 L.F. EACH END OF THE "T", OF PERFORATED PIPE, INTO THE DRAIN TILE SYSTEM. THE SHORTEST ROUTE WILL BE USED TO EXIT THE ROOF SYSTEM, WITH A MAX. OF 2 90 DEGREE ELBOWS. IN UNCONDITIONED AREAS, THE RADON EXHAUST PIPE WILLBE INSULATED WITH AN R4 SLEEVE. THIS PIPE WILL BE LABELED "PASSIVE RADON" AT ALL ACCESSIBLE LOCATIONS. AT ROOF EXIT LOCATIONS, MAINTAIN A 10' DISTANCE TO ANY WINDOWLOCATION, 2' BELOW EXHAUST POINT AND ANY ADJACENT STRUCTURE. THE LOCATION OF THE EXIT POINT, IN TRUSS AREA, WILL BE CLEAR OF ANY OBSTRUCTIONS WITHIN 24" HORIZONTALLY AND 36" VERTICALLY. INSTALL AN OUTLET AND PULL CHORD LIGHT FOR FUTURE EXHAUST FAN ADDITION. SCALE: 1/4" = 1'-0" MAIN FLR. ELECTRICAL PLAN 7 7 07-00-BUYERPROJECT # BUYER S/O BUYER S/O REVISIONS: STARTED: AGENT:X XLOT 9, BLOCK 12, SUMMERS CREEK17873 GRAPHITE LN., LAKEVILLE, MN"SONOMA" 1640 VILLA HOMEMARK ELLIOTT HOMES3-12-21 SELECT 4-22-2021 PERMIT OF SHEET SCALE: 1/4" = 1'-0" LOWER LEVEL ELECTRICAL PLAN SSTV TV W.P. FAN G.F.I.P.S3S3INSTALLED LTS.PENDANT 3SS C/L 7'-6"3'-2"5'-9 1/2"SD SD GDO G.F.I.P.SG.F.I.P.G.F.I.P.G.F.I.P. W.P.SS S 3S SSDISP SS TO LIGHT S G.F.I.P.DW GAS RANGEHOODVENT ABV.LNDRY. DRYER WASHER(VENT TO OUTSIDE)REF. KITCHEN GREAT ROOM FOYER PORCH O. BATH GARAGE O. CLST BEDROOM #2 / OFFICE OWNERS BDRM. SMOKECM / MUDRM. DINING SMOKE CM / SS S4S3S4S SS SS G.F.I.P.S3 S3 S3SS PANTRY BATH 3-SEASON PORCH F.D.W.P.NOTE: PROVIDE WIRING & GAS (FIELD VERIFY LOCATION) FOR FUT. HEATER FANINSTALLED 3 S (FIXTURE & INSTALL WIRE & CAP OPNG. BY BUYER) (FIXTURE & INSTALL WIRE & CAP OPNG. BY BUYER) (FIXTURE & INSTALL WIRE & CAP OPNG. BY BUYER) LED TAPEUC. LITELED TAPEUC. LITELED TAPEUC. LITES NOTE: FL. OUTLET C/L C/LS SMOKE CM / DUPLEX CONVENIENCE OUTLET DUPLEX OUTLET ABOVE COUNTER WEATHERPROOF DUPLEX OUTLET HALF-SWITCHED DUPLEX OUTLET DUPLEX OUTLET IN FLOOR 220 VOLT OUTLET WALL SWITCH THREE-WAY SWITCH FOUR-WAY SWITCH CEILING MOUNTED INCANDESCENT LIGHT FIXTURE WALL MOUNTED INCANDESCENT LIGHT FIXTURE RECESSED INCANDESCENT LIGHT FIXTURE LIGHT FIXTURE WITH PULL CHAIN TRACK LIGHT FLOURESCENT LIGHT FIXTURE EXHAUST FAN EXHAUST FAN/LIGHT COMBINATION CHIMES (OPTIONAL) SMOKE DETECTOR TELEPHONE (OPTIONAL) TELEVISION (OPTIONAL) THERMOSTAT ELECTRIC METER ELECTRIC PANEL SPEAKER (OPTIONAL) TV T M CH SD P.C. S S S 4 3 W.P. ELECTRICAL KEY DUPLEX OUTLET (GROUND FAULT PROTECTED)G.F.I.P. RECESSED INCANDESCENT EYE BALL FIXTURE CARBON MONOXIDE DETECTORCM GARAGE DOOR OPENER OUTLETGDO FLUORESCENT LIGHT PER SPEC FAN/LIGHT COMBO PREWIRE, PROVIDE ADEQUATE SUPPORT 4 BULB FIXTURE 3 BULB FIXTURE 200 AMP SERVICE LIGHTING PACKAGE: T.B.D. LINE TO DRYER: T.B.D.G.F.I.P.EXCH.AIR SMOKE CM / S S3S TO LIGHT A/C UNIT w/ BRACKET G.F.I.P.3 FURN F.D. WH MECH. BDRM. #3 FAMILY ROOM L.L. BATH SUMP UNEXCAVATED STORAGE OFFICE / BDRM. #4 CLST. H20 SD SD SSSSSS3SSS S S TVABV. FP.NOTE: TECH TUBE G.F.I.P. SMOKECM / WS (2) MINI RECESS @ BAR HUMIDIFIER APRILAIRE NOTE: UC REFR.OUTLET FOR BW 07-00-BUYERPROJECT # BUYER S/O BUYER S/O REVISIONS: STARTED: AGENT:X XLOT 9, BLOCK 12, SUMMERS CREEK17873 GRAPHITE LN., LAKEVILLE, MN"SONOMA" 1640 VILLA HOMEMARK ELLIOTT HOMES3-12-21 SELECT 4-22-2021 PERMIT 6-7-2021 REV. #1 N.T.S. MAIN LEVEL BRACEWALL2 BW N.T.S. BRACEWALL DETAILS3 BW GARAGE PORTAL FRAMING PER BUILDING CODE IRC R602.10.6.4 BRACED WALL METHOD CS-WSP4'-0" PANELBRACED WALLLINE 1BRACED WALLLINE ABRACED WALLLINE 23'-5" PANEL 6'-0" GYP. PANEL BRACED WALLLINE B BRACED WALL LINE C 3'-5" PANEL 3'-2" PANEL3'-2" PANEL 3'-5" PANEL 4'-0" PANEL4'-0" PANEL4'-0" PANEL4'-0" PANEL4'-0" PANEL4'-0" PANEL4'-0" PANEL4'-0" PANEL8'-0" GYP. PANEL 8'-0" GYP. PANEL 3'-3" PANEL 4'-2" PANEL 1'-4" PANEL LNDRY. KITCHEN GREAT ROOM FOYER PORCH O. BATH GARAGE O. CLST BEDROOM #2 / OFFICE OWNERS BDRM. MUDRM. DINING PANTRY BATH 3-SEASON PORCH 2'-2" PANEL2'-2" PANEL MIN. 3''x11 1/4'' NET HEADER(STEEL HDR. PROHIBITED) EXTENT OF HEADER W/ SINGLE PORTAL FRAME ONE BRACED WALL PANEL 10'-0'' MAX. HEIGHT(TOP OF HDR.)TOP OF FDN. TOP OF CONC FLOOR AT OPENING MIN. 2-2x4 FRAMING STUD POST CONTINUOUS HEADER WITH DOUBLE PORTAL FRAMES TWO BRACED WALL PANELS 6' TO 18' OPENING FASTEN TOP PLATE TO HEADER W/ 2ROWS OF 16d SINKER NAILS @ 3'' O.C. TYP. 1000 LB. STRAP OPPOSITE SIDE OF SHEATHING FASTEN SHEATHING TO HEADER W/ 8d COMMON OR GALV. BOX NAILS IN 3'' GRIDPATTERN SHOWN AND 3'' O.C. IN ALLFRAMING(STUDS, BLOCK'G AND SILLS)TYP. MIN. WIDTH PER TABLE R602.10.5 3/8'' MIN. WOOD STRUCTURAL PANEL SHEATH'G. MIN. 2-2x4 MIN. 4200 LB. TIE DOWN DEVICE(EMBED INTOFOUNDATION AND NAILED INTO FRAMING MIN. (2) 1/2'' DIA. ANCHOR BOLT INSTALLED PER R403.1.6 W SEE LEFT FORTYP. PORTALFRAME CONST. FOR A PANEL SPLICE(IF NEEDED) PANEL EDGES SHALL BEBLOCKED AND OCCURWITHIN 24'' OF MID- HEIGHT. ONE ROW OFTYP. SHEATH'G. TOFRAMING NAILING IS REQUIRED.IF 2x4 BLOCK'G. IS USEDTHE 2x4'S MUST BE NAILED TOGETHER W/ 3 16dSINKER NAILS W/ 2''x2''x3/16'' PLATE WASHER12'-0'' MAX. HEIGHT(TOP OF WALL)FULL HEIGHT OF WALL - SEE TO RIGHT FOR SPLICESPONY WALL HT.EXTENT OF HEADER TENSION STRAP PERTABLE R602.10.6.4 (ONOPPOSITE SIDE OF SHEATHING ANCHOR BOLTSPER SECTION R403.1.6 BRACED WALL LINECONTINUOUSLYSHEATHED WITH WOOD STRUCTURALPANELS TOP OF FLOOR AT OPENING FLOOR FRAMING ASSEMBLY PER PLAN W/ WOOD STRUCTURAL PANEL SHEATHING TOP OF FLOOR AT OPENING FLOOR FRAMING ASSEMBLY PER PLAN WOOD STRUCTURAL PANEL SHEATHING TO TOP OF BAND OR RIM JOIST NAIL SOLE PLATE TO FLR FRAMING PERTABLE R602.3(1) (2) FRAMING ANCHORS APPLIED ACROSSSHEATHING JOINT WITH A CAPACITY OF 670# IN HORIZ. AND VERT. DIRECTIONS SEE LEFT FOR TYP. PORTALFRAME CONST. ON CONCRETE FOUNDATION ON RAISED WOOD FLOOR - FRAMING ANCHOR OPTION TOP OF FLOOR AT OPENING FLOOR FRAMING ASSEMBLY PER PLAN W/ WOOD STRUCTURAL PANEL SHEATHING TOP OF FLOOR AT OPENING FLOOR FRAMING ASSEMBLY PER PLAN WOOD STRUCTURAL PANEL SHEATHINGTO TOP OF BAND OR RIM JOIST NAIL SOLE PLATE TO FLRFRAMING PERTABLE R602.3(1) SEE LEFT FORTYP. PORTALFRAME CONST. ON RAISED WOOD FLOOR - OVERLAP FLOOR OPTION MIN. OVERLAP 9 1/4''WOOD STRUCTURAL PANEL SHEATHING CONTINUOUS OVER BAND OR RIM JOIST MIN. OVERLAP 9 1/4''ATTACH TO RIM/BAND JOIST W/ 8d COMMON NAILS AT 3'' O.C. AS SHOWN DBL TOP PLATE BOTTOM PLATE STUDS AT 16'' O.C. W/ 6d NAILS @ 6'' O.C. 4'-0"8'-0'' MIN., SEE PLANINTERMEDIATE 6''3"W/ 6d NAILS @ 3'' O.C. EDGES NAILED J2J2J2J2J2J2J2J2J2J2F1-SGJ6 J7 J9 J9 J9 J9 J9 J9 J9 J9 J9 J9 J9 J8 J8 J8 J8 J8 J8 J8 J8 J 10 J11J11J12 J13 J14 J15 J16 J8 J8 J8 J8 J8 J8 J8 J8 J8 J8 J8 J8 J8 J8 J8 D5D6D7PB2PB3PB3D8E1E1E2PB3PB3PB3PB3B1-GE B2 B2 C1-GR C2 C3 J17 J17 J17 J17 J17 J18 J19 J9 J9 J9 J9E2E3E4E5-GRPB4G1-GE G2 G2 G2 G2 G3 J1D1-GRD2D3D4PB1A1-GR J20J20J20PG1PG5 PG4 PG3PG2V18 V9 V8-GE V10 V11 V12 V13 J3J4J4J5J5J5J5C4-GR V14 V15 V16 V17 V1 V2 V3 V4 V5 V6 V7 40' 5'11"4 5'11"4 6'10'12'6"13'14'6"4'33'29'6'52'10'2'19'21' TRUSS END MARKED WITH (X) CORRESPONDSWITH THE LEFT END ON THE TRUSS DRAWINGS. BOX VAULTS ARE MADE 1 1/2" LARGER FOR2x4 FRAMING. ROOF TRUSS LAYOUT LUS24 HANGERS TYPLUS24 HANGERS TYPLUS24 TYP DORMER HHUS26-2HUS26 HANGERS TYP12" RAISED CEILINGHUS26 HANGERS TYPHHUS26-2 Created by BAM version 052009 New Construction Energy Code Compliance Certificate Place your logo here Per N1101.8 Building Certificate. A building certificate shall be posted in a permanently visible location inside the building. The certificate shall be completed by the builder and shall list information and values of components listed in Table N1101.8. Date Certificate Posted Mailing Address of the Dwelling or Dwelling Unit City 17873 Graphite lane lakeville Name of Residential Contractor MN License Number Mid State Plumbing & Htg PM64995 THERMAL ENVELOPE RADON SYSTEM Insulation Location Total R-Value of all Types ofInsulationType: Check All That Apply X Passive (No Fan)Non or Not ApplicableFiberglass, BlownFiberglass, BattsFoam, Closed CellFoam Open CellMineral FiberboardRigid, Extruded PolystyreneRigid, IsocynurateActive (With fan and monometer or other system monitoring device) Other Please Describe Here Below Entire Slab Foundation Wall R-15 x Exterior 2" CertiStud -- Interior 3/4" Thermax Perimeter of Slab on Grade R-10 x Rim Joist (Foundation)N/A Rim Joist (1st Floor+)N/A Interior Wall R-21 x Ceiling, flat R-49 x Attic Ceiling, vaulted R-38 x Bay Windows or cantilevered areas N/A Interior Bonus room over garage N/A Exterior & Interior Describe other insulated areas Windows & Doors Heating or Cooling Ducts Outside Conditioned Spaces Average U-Factor (excludes skylights and one door) U: 0.29 X Not applicable, all ducts located in conditioned space Solar Heat Gain Coefficient (SHGC):0.28 R-value MECHANICAL SYSTEMS Make-up Air Select a Type Appliances Heating System Domestic Water Heater Cooling System X Not required per mech. code Fuel Type Natural Gas Natural Gas Electric Passive Manufacturer Bryant Bradford White Bryant Powered Model 912S MITW50 113A Interlocked with exhaust device. Describe: Rating or Size Input in BTUS:42973 Capacity in Gallons: 50 Output in Tons:2 X RenewAire Exchanger EV90 Structure's Calculated Heat Loss: Heat Gain:19,737 Basement and Duct in Floor trusses Efficiency AFUE or HSPF% 92.00% SEER: 13 Calculated cooling load: 19,737 Cfm's " round duct OR Mechanical Ventilation System " metal duct Combustion Air Select a Type Not required per mech. code Select Type X Passive Heat Recover Ventilator (HRV) Capacity in cfms:Low: Variable High:Other, describe: x Energy Recover Ventilator (ERV) Capacity in cfms:Speed High: Location of duct or system: Continuous exhausting fan(s) rated capacity in cfms:6 " 0 Location of fan(s), describe: Mechanical room in Garage Cfm's Capacity continuous ventilation rate in cfms:73 CFM X " round duct OR Total ventilation (intermittent + continuous) rate in cfms:145 CFM " metal duct NEW RESIDENTIAL CONSTRUCTION SWPPP VERIFICATION This form must be completed and submitted with all new residential permit applications. A National Pollutant Discharge Elimination System (NPDES) Construction Stormwater Permit is required for “Construction activity that results in land disturbance of equal to or greater than one (1) acre or if a project is part of a common plan of development that will ultimately disturb greater than one (1) acre,” (NPDES Permit, Section 1.2). Project Site Address: _____________________________________________________________________ Company Name: _________________________________________________________________________ *Primary Company Contact: _________________________________________________________________ *Should a site be deemed noncompliant, this individual will be notified Phone #: ____________________________ Email: ______________________________________________ If you are not covered under a NPDES Construction Stormwater Permit administered by the Minnesota Pollution Control Agency (MPCA), an erosion and sediment control plan MUST be approved as part of the residential building permit application. “Permittees must ensure a trained person will inspect the entire construction site at least once every seven (7) days during active construction and within 24 hours after a rainfall event greater than ½ inch in 24 hours,” (NPDES Permit, Section 11.2). The City of Lakeville reserves the right to request weekly inspection logs. The City of Lakeville may issue a STOP WORK ORDER; withhold building inspections; or, draw on securities/escrows to bring the site into compliance with the NPDES Construction Stormwater Permit (MN R 100001) or erosion and sediment control plan. Contact information of person CERTIFIED to provide weekly onsite erosion and sediment control inspections and corrective actions: Name: ____________________________________ Company: ___________________________________ Phone # (24 hr Contact): ______________________ Email: ______________________________________ Entity that Provided Training: __________________________ Certification Expiration Date: ____________ NOTE: Prior to any land-disturbing activity, all erosion and sediment controls must be installed I understand the above information to be accurate and I have read, understood, and accepted all terms and conditions of the NPDES Permit (MN R 100001). Signature: ________________________________________________ Date:_________________________ Contact the City of Lakeville with questions at erosion@lakevillemn.gov or 952-985-4500 Nick Reimler X05/25/21 KP