HomeMy WebLinkAboutLA192729 - 17873 Graphite Lane Permit PackRESIDENTIAL BUILDING
PERMIT APPLICATION
CITY OF LAKEVILLE
BUILDING INSPECTIONS DEPARTMENT
20195 HOLYOKE AVENUE
LAKEVILLE, MN 55044
952-985-4440
Office Use Only
__________________
Permit Number
___________________
Received By
___________________
Date Received
___________________
Fee Total
SITE ADDRESS:
MAILING ADDRESS: CITY: STATE: ZIP:
JOB DESCRIPTION:__________________________________ MASTER PLAN: (Number or Address)____________________
LIST OTHER STRUCTURES ON PROPERTY:_______________________________________________________________
ESTIMATED VALUATION: PROPOSED START DATE: END DATE:
(New Residential Only): LEGAL DESCRIPTION: LOT: _____ BLOCK: _____ SUBDIVISION:
APPLICANT IS: RESIDENT OWNER CONTRACTOR EMAIL
NEW MODEL HOME: YES NO (IF YES – ADMINISTRATIVE PERMIT REQUIRED)
PLEASE FILL OUT THE FOLLOWING COMPLETELY (All Contractor information must be as listed on State License)
RESIDENT OWNER
NAME:_______________________________________________________________________________
HOME PHONE #:_____________________________ CELL PHONE:___________________________
GENERAL CONTRACTOR
Homeowner
Contractor
CONTRACTOR:_______________________________________________________________________
LICENSE #:BC______________ LEAD CERTIFICATE#_______________ (PRE 1978 STRUCTURE)
OFFICE PHONE #:_____________________________ CELL PHONE:___________________________
ADDRESS:____________________________ CITY:________________ ST:______ ZIP:____________
PLUMBING WORK
Homeowner
Contractor
CONTRACTOR:__________________________________________LICENSE #: PM______________
OFFICE PHONE #:_____________________________ CELL PHONE:___________________________
ADDRESS:____________________________ CITY:________________ ST:______ ZIP:____________
MECHANICAL WORK
Homeowner
Contractor
CONTRACTOR:________________________________________ _______________________________
OFFICE PHONE #:_____________________________ CELL PHONE:___________________________
ADDRESS:____________________________ CITY:________________ ST:______ ZIP:____________
BOND #:_______________________________________ EXPIRATION DATE____________________
SEWER/WATER CONTRACTOR
New Construction Only
NAME:________________________________________________ ______________________________
HOME PHONE _____________________________ CELL PHONE:______________________________
BOND #:_______________________________________ EXPIRATION DATE____________________
INTEREST EARNINGS ON THE ESCROW ACCOUNTS, IF ANY, ARE RETAINED BY THE CITY TO OFFSET THE
ADMINISTRATIVE COSTS ASSOCIATED WITH PROCESSING THE ESCROW APPLICATION AND REFUND. I HEREBY
APPLY FOR A BUILDING PERMIT AND I ACKNOWLEDGE THAT THE INFORMATION ABOVE IS COMPLETE AND
ACCURATE; THAT THE WORK WILL BE IN CONFORMANCE WITH THE ORDINANCES AND CODES OF THE CITY AND
WITH THE STATE BUILDING CODE, THAT I UNDERSTAND THIS IS NOT A PERMIT AND WORK IS NOT TO START
WITHOUT A PERMIT AND THAT THE WORK WILL BE IN ACCORDANCE WITH THE APPROVED PLAN.
NAME OF APPLICANT (Please Print)DATE
APPLICANT’S SIGNATURE:
www.lakevillemn.gov
Nick Reimler
RESIDENTIAL BUILDING PERMIT APPLICATION
PAGE 2
OFFICE USE ONLY
BUILDING PERMIT TYPE REQUIRED INSPECTIONS
SINGLE FAMILY DWELLING BUILDING
DUPLEX AS BUILT
TOWNHOUSE UNITS BUILDING FINAL
DETACHED TOWN HOUSE UNIT DECK FOOTING
CONDO FIREPLACE
ACESSORY BUILDING FOOTING
REROOF FOUNDATION
RESIDE FRAMING
PORCH FRAMING
GARAGES
INSULATION
RES ADDN/REPAIR/RMDL
DECK
PORCH
GARAGES LATH
LOWER LEVEL FINISH LOWER LEVEL FINAL
ADDITION OTHER
FOUNDATION ONLY PORCH FOOTING
MISCELLANEOUS POURED WALL
DEMO SEPTIC TANK REMOVAL
MOVED SITE
MECHANICAL
CITY BUILDING VALUATION: $AIR TEST
FINAL
BUILDING PERMIT FEES ROUGH-IN
$PERMIT FEE PLUMBING
$PLAN CHECK FINAL
$SURCHARGE ROUGH-IN
$METRO SAC METER SIZE
$CITY WATER HOOKUP UNIT PRESSURE REDUCING VALVE
$CITY SEWER HOOKUP UNIT SEWER/WATER
$LANDSCAPE ESCROW SEWER/WATER
$TREE ESCROW FINAL
$MISC ESCROW STREET DRAINTILE
$PLUMBING BUILDING INFORMATION
$MECHANICAL TYPE OF CONSTRUCTION
$SEWER WATER ZONING
$OTHER CODE EDITION
$TOTAL FIRE SUPPRESSION SYSTEM
OCCUPANCY GROUP
APPROVED BY:
BUILDING INSPECTOR: Date:
PLUMBING/MECHANICAL
INSPECTOR: Date:
COMMENTS:
20195 Holyoke Avenue, Lakeville, MN 55044
952-985-4400 952-985-4499 fax
www.lakevillemn.gov
Sewer & Water Tie Card
Address:________________________________________
Contractor:______________________________________
Permit Number:__________________________________
Final Date:________________
Street Drain-Tile:______
Size of Water Service: 1”
Comments: AIRTEST SANITARY OVER 20’/2 FITTINGS
THIS CARD MUST BE COMPLETED AND ON-SITE AT TIME
OF SEWER & WATER INSPECTION
1 7SCALE: 1/4" = 1'-0"
FRONT ELEVATION
GENERAL NOTES:
1. ALL DOOR AND WINDOW HEADERS TO
BE S.P.F. #2 OR BETTER, SEE PLANS FOR
SIZES.
2. HOUSE TO BE BUILT PER CURRENT
I.R.C. CODES.
3. VERIFY GRADES AND ADJUST
FOUNDATION/FOOTING STEPS AS
NEEDED.
4. SEE PLANS FOR CEILING HEIGHTS
5. 4' HIGH POURED FDN. WALLS STD.
6. FLOOR PLAN DIMENSIONS ARE TO
FACE OF FRAMING AND FOUNDATION.
7. ALL TRADES & SUPPLIERS TO REVIEW
& VERIFY INFORMATION PERTINENT TO
THEIR WORK AND NOTIFY CONST. OF ANY
DISCREPANCIES PRIOR TO CONSTRUCTION.
8. NOTED CABINET SIZES ARE +/- AND
TO BE FIELD VERIFIED.
9. TRADES TO VERIFY BASE AND TRIM
SIZE PRIOR TO CONSTRUCTION.
10. ALL WALLS MORE THAN 10' H. TO BE
S.P.F. #2 OR BETTER.
11. EXTERIOR ELEVATIONS ARE CONCEPTUAL ONLY:
HOME SITE, FILL AND TOPOGRAPHY WILL DICTATE
ACTUAL GRADES AND MAY VARY FROM THOSE
SHOWN ON THE PLAN.
12. NOTE: SUBFLOOR JOINTS SHALL BE
STAGGERED FROM FLOOR TRUSS OR
JOIST JOINTS
OF
SHEET
07-00-BUYERPROJECT #
BUYER S/O
BUYER S/O
REVISIONS:
STARTED:
AGENT:X
XLOT 9, BLOCK 12, SUMMERS CREEK17873 GRAPHITE LN., LAKEVILLE, MN"SONOMA" 1640 VILLA HOMEMARK ELLIOTT HOMES3-12-21 SELECT
4-22-2021 PERMIT
SCALE: 1/8" = 1'-0"
ROOF PLAN
SEE ROOF PLAN FOR
ROOF PITCHES AND
OVERHANGS
25'-9"CONC. PORCH
4" TRIM TYP.
6:12
8'-2"T.O. 3648 FX
ALUM. SOFFIT
& FASCIA
30 YR. ARCH.
ASPHALT SHINGLES
6" TRIM
14" LP COLUMNLP PANEL
9'-1 1/8"T.O. SUBFLR.
T.O. PLATE 1'-8 1/4"T.O. FDN.9'-1 1/8"@ GARAGE
T.O. PLATE
12
12
12
12
(BLACKENED)1'-0"6" TRIM12" CANT.
10" TRIM
C/L
T.O. FDN.11"@ DORMERT.O. PLATE
10'-0"FP CHASE
24"x60" FALSE
6" TRIMLP SIDING
PER SPECS
STONE CAP
STONE TOTAL: 84.77 SQ. FT. (26.97%)
TOTAL SQ. FT.: 314.26
MATERIAL CALCULATIONS: FRONT ELEV.
LP LAP SIDING TOTAL: 31.28 SQ. FT. (9.95%)
LP B/B TOTAL: 118.29 SQ. FT. (37.57%)
LP TRIM / PANEL: 79.92 SQ. FT. (25.51%)
STONE TOTAL: 107.24 SQ. FT. (8.7%)
TOTAL SQ. FT.: 1,833.77
MATERIAL CALCULATIONS: ALL ELEV.
LP LAP SIDING TOTAL: 1,179.50 SQ. FT. (36.9%)
LP B/B TOTAL: 203.86 SQ. FT. (3.5%)
LP TRIM / PANEL: 343.17 SQ. FT. (16.9%)
LP SMARTSIDE BD.
& BATTEN SIDING
12
12
12
12
12
12
12
12
6:12
LP SMARTSIDE BD.
& BATTEN SIDING
6" TRIM
T.O. PLATE 3.25 +/-:12
10'-3"
6'-7"
6" TRIM SADDLENOTE:
SEE ROOF TRUSS LAYOUT
FOR TRUSS DIRECTION
AND GIRDER LOCATIONS
PROVIDED BY MANUFACTURER
PROVIDE ATTIC VENTILATION EQUAL TO 1/150th
ATTIC AREA. IF 50% OR MORE IS PROVIDED IN
UPPER PORTION OF THE ROOF AND REMAINDER
IS PROVIDED IN SOFFIT VENTS, IT MAY BE
REDUCED TO 1/300th ATTIC AREA.
ICE AND WATER SHIELD
6'-0" IN FROM EAVES
1'-6" ON EACH SIDE OF VALLEY
WHERE WALLS MEET ROOF
ICE & WATER SHIELD SHOULD
RUN UP WALL 1'-6" AND OUT
FROM WALL 1'-6"
NOTE:
NOTE:
NOTE:
1'-6"2'-0"RIDGERIDGE
2'-0"1'-6"6:126:1212:12
2'-0"1'-0"4'-11"1'-6"
1'-6"2'-0"1'-0"
12:12 RIDGE12:12 12:12
6:121'-0"12:12
12:12
12:12 12:12
6:123.25:121'-0"1'-6"
12:12 12:12
1'-0"1'-6"1'-6"4'-0"Concept Approval
ONLY
Subject to Field Inspection
Inspector Date
2020
MN Bldg
Code
07/13/2021dmathews
EXTERIOR ELEVATIONS ARE CONCEPTUAL ONLY:
HOME SITE, FILL AND TOPOGRAPHY WILL DICTATE
ACTUAL GRADES AND MAY VARY FROM THOSE
SHOWN ON THE PLAN.2 7
07-00-BUYERPROJECT #
BUYER S/O
BUYER S/O
REVISIONS:
STARTED:
AGENT:X
XLOT 9, BLOCK 12, SUMMERS CREEK17873 GRAPHITE LN., LAKEVILLE, MN"SONOMA" 1640 VILLA HOMEMARK ELLIOTT HOMES3-12-21 SELECT
4-22-2021 PERMIT
OF
SHEET
SIDE ELEVATION
SCALE: 3/16" = 1'-0"
REAR ELEVATION
SIDE ELEVATION
SCALE: 3/16" = 1'-0"
SCALE: 3/16" = 1'-0"
@ GARAGE
9'-1 1/8"T.O. FDN.A/C UNIT
T.O. PLATE
9'-1 1/8"T.O. SUBFLR.
T.O. FDN.1'-8 1/4"12
6
12
6
T.O. PLATE
ALUM. SOFFIT
& FASCIA PER SPECS
SEE ROOF PLAN
FOR PITCHES AND
OVERHANGS
12:12
12:12
12:12
10" TRIM
ROOF LINE
BEYOND
12:12
12:12
LP SIDING
12
3.25
4" LP TRIM @ WDWS. & DOORS TYP.
10" TRIM
LP PANEL
12" CANT.
FP VENT
STONE4" LP TRIM @ WDWS. & DOORS TYP.
WHERE INDICATED
T.O. PLATE
9'-1 1/8"T.O. SUBFLR.
T.O. FDN.1'-8 1/4"12
6
12
6
ALUM. SOFFIT
& FASCIAPER SPECS
SEE ROOF PLAN
FOR PITCHES AND
OVERHANGS
12:12
12:1212:12
12:12
10" TRIM
LP SIDING
12
3.25
ROOF LINE
BEYOND LP SIDING
PER SPECS
EGRESS
SEE ROOF PLAN
FOR PITCHES AND
OVERHANGS
ALUM. SOFFIT
& FASCIA
6:12
LP SIDING
PER SPECS
12
12 12
12
12
1212
12
T.O. PLATE
9'-1 1/8"T.O. SUBFLR.
T.O. FDN.1'-8 1/4"4" LP TRIM @ WDWS. & DOORS TYP.
10" TRIM 10" TRIM
EGRESS
6:12
12" CANT.
Secure door closed until deck is
constructed with a separate permit.
SCALE: 3/16" = 1'-0"
FOUNDATION PLAN
3 7
07-00-BUYERPROJECT #
BUYER S/O
BUYER S/O
REVISIONS:
STARTED:
AGENT:X
XLOT 9, BLOCK 12, SUMMERS CREEK17873 GRAPHITE LN., LAKEVILLE, MN"SONOMA" 1640 VILLA HOMEMARK ELLIOTT HOMES3-12-21 SELECT
4-22-2021 PERMIT
OF
SHEET
A/C UNIT
w/ BRACKET
FURN
F.D.
WH
MECH. 3068 2668
BDRM. #3
FAMILY ROOM
L.L. BATH 36" V.CONC.
H.B.
H.B.
2" LEDGE TYP.
TO PROVIDE ADD'L.SUPPORT FOR
FILL FOR SLAB
TYP. FND @ HOUSE / GARAGE
10" POURED CONC.
W/ 4" LEDGE INSIDE
20X8 CONC. FTG.
2" FOAM
SUMP
H20
4" LEDGE
2" FOAM
TYP. FND @ STOOP
12" POURED CONC.
W/ 4" LEDGE INSIDE
20X8 CONC. FTG.
UNEXCAVATED
2"
NOTE: NO DRYWALL @ CLG.
REQUIRED IN THIS AREA -
FIRE BLOCK @ PERIMETER
OF OPNG. (80 SQ. FT. MAX.)
6"2"
RADON VENT TO
TERMINATE IN SUMP BASKET
6"
4"
10"
GARAGE/HOUSE
COMMON WALL
2x8 TREATED SILL
OVERHANG FDN. 2''
GARAGE SLAB
2'' RIGID INSUL.
MAIN FLR
SEE FIRST FLOOR FOR
GARAGE DOOR SIZE FOR M.O.
NOTE:
4" LEDGE
6"2"CARPET
CARPET
3 1/2'' CONC. FLOOR
TYP. FND @ HOUSE
8" POURED CONC (9'-0" H.)
20X8 FTG
REBAR PER CODE
TYP. FND @ BRG. WALL
2x4 STUDS 16" O.C.
16X8 FTG
REBAR PER CODE
4" CONC. CURB
KITCHEN ISLAND ABV.
FLR. TRUSS CO.
2
4
6
8
18" FLR. TRUSSES19.2" O.C. SPACING2-2x10 (DR)
(11'-3"x12'-7")
(25'-6"x12'-6")
RADON VENT
NOTE: EXTERIOR HOUSE AND GARAGE/HOUSE
COMMON FDN. WALLS TO BE HELD 2'' IN.
DIMENSIONS SHOWN ARE TO FACE OF 2''
EXTERIOR RIGID INSULATION & FRAMING ABOVE
TO BE 5000 PSI CONC.NOTE: ALL FOOTINGS
2'' MIN.
2x8 TREATED
SILL-OVERHANGFDN. 1 1/2''8"
2"
TYP. SIDE
WALL DETAIL
FOUND. HELD IN 2"
FOR INSULATION
NOTE:
(TYP.)2"2"2"2"
9'-0" POURED FDN.
APPROX. 1,678 NET SQ. FT.
FILL FOR SLAB
UP 17 R (10" T.,
7-3/4" MAX. R.)
14'-6"12'-0"58'-0"6'-0"52'-0"66'-0"4'-0"29'-0"33'-0"10'-0"14'-0"10'-6 1/2"10'-0"12'-0"2'-0"19'-0"40'-0"
19'-0"21'-0"
19'-5 1/2"
& HOUSE/PORCH
10'-9"10'-3"18" FLR. TRUSSES19.2" O.C. SPACINGFOUND. HELD IN 2"
FOR INSULATION
NOTE:
(TYP.) 20682x10 TRTD. JOISTS16" O.C. SPACING3-2x10 TRTD. (FL)
SMOKECM / 12" CANT. ABV.2x6 BRG.
2x6 BRG.
10'-0" H. FOUND. WALL
@ FRONT OF HOME
NOTE:
10'-0" H. FOUND. WALL
@ FRONT OF HOME
NOTE:
w/ TOP HUNG TRUSSES
w/ TOP HUNG TRUSSES
10'-0" H. FOUND. WALL
@ FRONT OF HOME
NOTE:
w/ TOP HUNG TRUSSES
10'-2 1/2"3'-10 3/4"6'-8 3/4"
13'-1"3'-2"13'-9"10'-0"3'-9"3'-10"6'-4"19'-8 1/2"9'-2 1/2"19'-3"7'-0 1/2"12'-5"
30"x30" CONC.
PAD FTG.
6x6 COL.
16" DIA. FROST
FOOTING (60" D.)
6x6 TRTD. COL.
2-2x10 (FL)
(2) TR
2-9 1/2" LSL (DR)
2
4
6
8
3'-2"2'-8"4'-0"3'-4 1/4"8'-0"9'-5 1/2"1'-5 1/4"20'-0"
40'-0"
6'-9"6'-9"
5'-0"4'-0"CONC. WDW WELL
3042 CSMT
2-9 1/2" LSL
3'-8"4'-11"
26'-6"13'-6" 2668STORAGE
CONC. 2668OFFICE / BDRM. #4
CARPET
(11'-0"x10'-2")5'-0"4'-0"CONC. WDW WELL3042 CSMT2-9 1/2" LSL3'-8"42" GAS F.P.2'-0"
R&SH
2 - 2068
CLST.
CARPET 5'-0"P.H.
TR
LVP FLR.(4) SH. LINENCARPET
CARPET
CARPET
BAR SINK
EXCH.AIR
SD
SMOKECM /
TYP. FND @ HOUSE
8" POURED CONC (9'-0" H.)
20X8 FTG
REBAR PER CODE
WS
FIBRGLS.
60x32 SHWR.
UNIT
HUMIDIFIER* APRILAIRE
NOTE:
OPNG. FOR
NOTE:
UC REFR.6'-0 1/4"6'-9"3/0 x 7/0 SRO3'-2"4'-0"8'-5"3'-10"2'-5"22'-9"5'-0"2'-10"TB8'-6"2'-2"(3)2x10 #1 SP or
(3)2x12 #2 SP
Provide
footing below
bearing wall.
UFER Ground
-Provide 20' Rebar in footing and stub
up near electrical service panel.
BWPs
Above
Smoke
SCALE: 3/16" = 1'-0"
MAIN FLOOR PLAN
4 7
07-00-BUYERPROJECT #
BUYER S/O
BUYER S/O
REVISIONS:
STARTED:
AGENT:X
XLOT 9, BLOCK 12, SUMMERS CREEK17873 GRAPHITE LN., LAKEVILLE, MN"SONOMA" 1640 VILLA HOMEMARK ELLIOTT HOMES3-12-21 SELECT
4-22-2021 PERMIT
6-7-2021 REV. #1
OF
SHEET
P.H.TBTR
DW
GAS RANGEHOODVENT ABV. FLUSH OH.
LNDRY.
DRYER WASHER
9' CLG. / LVP
WIRE SH. (VENT TO OUTSIDE)NOTE:
- STD. BASE & CASING TO BE PRINCETON
- 1/2 WALL w/ WD. CAP & INVERTED CASING
NOTE:
2X6 EXT. WALLS U.N.O.
2X4 INT. WALLS U.N.O.
- 42" UPPER CABINETS
DOOR ROUGH OPENINGS:
83" HEIGHT
82" OVER VINYL
CERAMIC TILE & WOOD
82" OVER CARPET
SRO = SHEET ROCKED OPNG
BIFOLD DOORS:
PREHUNG UNITS:
2" WIDER THAN DOOR
(EXAMPLE: 2668 )
1 3/8" WIDER THAN DOOR
FINISH SIZE NOTED ON PLAN
CO = CASED OPENING ( WOOD )
(EXAMPLE: 2668 )
FINISH SIZE NOTED ON PLAN
RO. 1 1/2" WIDER, 83" HIGH
R.O. 1" WIDER, 83" HIGH
PER SPECS
DRIVEWAY
NOTE:
REF.
KITCHEN
9' CLG. / LVP13'-2" x 12'-6"
(155 SQ. FT.)
3-16" LVL
GREAT ROOM
9' CLG. / LVP FLR.42" GAS F.P.12'-8" x 15'-0" (196 SQ. FT.)
/ LVP
42" W. CONC. SIDEWALK
FBRGLS. BASE
60x36 SHWR.
C.T. WALLS
5'-0"21068FOYER
9' CLG. / LVP
5'-10" x 11'-8"
(69 SQ. FT.)
PORCH
CONC. / BEADBD. CLG.
O. BATH
9' CLG. / VIN.
2x6 WALLS U.N.O.
4" SLOPED CONC.
GARAGE CEIL. TO BE 5/8" TYPE 'X'
GYP. BD. WALLS TO BE 1/2" GYP.SHEATHING. ALL WALLS & CEILINGS TO
HAVE ONE COAT FIRETAPE
GARAGE
6'x8' PATIO DR.
16'x7' O.H.D.
R.O. 16'-1" FRAMING
O. CLST
8' CLG. /
CARPET 36" VAN. BATH
BEDROOM #2 / OFFICE 26683648 SH @ 8'9' CLG. / LVP FLR.
w/ WD. CAPMANUF. TRUSSES24 O.C.(12'-3"x12'-0")
EXTERIOR FLOOR PLAN DIMENSIONS
ARE TO OUTSIDE OF SHEATHING, INTERIOR
DIMENSIONS ARE TO FRAMING.
NOTE:
ALL DRS/ WIN.'S REQUIRE
4" ON SIDES FOR CASING
NOTE:
2X6 EXT. WALLS U.N.O.
2X4 INT. WALLS U.N.O.
HEADER SPANS:
UP TO 4'-11'' = 1 TRIMMER
5'-0'' AND BIGGER = 2 TRIMMERS
UNLESS NOTED OTHERWISE
INDICATES LOCATION OF SOLID BRG.
(150 SQ. FT.)
OWNERS BDRM.
BOX VAULT / CARPET
(12'-6"x13'-7")
(173 SQ. FT.)
SMOKECM /
SD
2 - 4072 SH @ 8'
DN 17 R (10" T.,
7-3/4" MAX. R.)
8/0 H. SOFFIT
MANUF. TRUSSES24 O.C.ATTICACCESSAPPROX. 553 SQ. FT.
MUDRM.
9' CLG. / LVP
APPROX. 9'-0'' CLG. @ MAIN LEVEL
APPROX. 1,678 SQ. FT.
3
0
6
8
M
T
L
.3080 MTL.2468R&SH
R&SH9' CLG. /
LVP FLR.9' CLG.
8' SOFFIT 28682668R&SHR&SH36" VAN. LIN.CAB. 3068BASE CAB.w/ LTUB.
2 - 4072 SH @ 8'30" VAN. DINING
9' CLG. / LVP FLR.11'-0" x 14'-10" (168 SQ. FT.)
3672 SH @ 8'3672 SH @ 8'4872 PICT. @ 8'
3-SEASON PORCH
DECKING PER SPECS
MANUF. TRUSSES24 O.C.40'-0"
14'-6"12'-0"
8'-6"11'-10"6'-2"
6'-9"68'-0"6'-0"52'-0"12'-8"4'-10"5'-8"12'-8 3/4"7"4'-11"5'-2 1/2"5'-4 3/4"7'-8 1/4"5'-0 1/2"68'-0"4'-0"29'-0"33'-0"6'-9 1/2"14'-4"3'-2"10'-6 1/2"10'-0"12'-0"2'-0"19'-0"40'-0"
19'-0"21'-0"
13'-0"6'-0"
6'-7"6'-5"
10'-9"10'-3"
RADON VENT
SD
SMOKECM / 2'-10 1/4"2'-4 1/2"2424 PICT. @ 8'2424 PICT. @ 8'2'-6 1/2"2'-6 1/2" 3068 BARN DR.2448 SH @ 8'5'-0"WD. STEP
3'-11 1/4"6'-0 3/4"
2'-0"
16'-10 1/2"
2'-7 1/2"2'-4"4'-0"5'-0"12"
CANT.6'-4"8'-0"3'-9"3'-9"3'-0"3'-0"2-2x102-2x102-2x102-2x104 1/2"4 1/2"MANUF. TRUSSES24 O.C.FP CHASEFALSE
2-9 1/2" LSL (CONT.)2-9 1/2" LSL
2-2x10
(2) TR
2-2x10
P.H.
TR
3068 PKT.3'-6"6'-0"3'-6"5'-0"13'-6"
6'-9"
26'-6"10'-0"21068TR
R&SH
R&SH
1/2 WALL R&SHR&SH
26689'-7 1/2"9'-6 1/2"2668
PANTRY
9' CLG. / LVP
(5) SH.
9' CLG.
/ LVP
2468R&SH2/10 x 6/7 SRO6'-0 3/4"4'-3"2'-10 1/2"6'-8 3/4"7"2'-5"4'-8 1/2"5'-10"12'-2 3/4"7"6'-2 1/4"5'-7 3/4"2'-5 1/2"5'-7"4'-9 1/4"
1'-0"
11"5'-2"5'-10"2'-1"2'-5 1/4"2x65'-11 1/4"
3'-9"
8'-4"
GIRDER TRUSS
(3) 2x6
(3) 2x6
MANUF. TRUSSES
24 O.C.
9 1/2"7'-10 1/2"2'-3"3-9 1/2" LVL
2-2x10
60x32FBRGLS.SHWR. UNITPA
7"5'-0"5'-8"2'-10"
14" LP COL.
4"12'-0"2-7 1/4" LSL (DR)4"LP SOFFIT
4"4"7'-4"
2-7 1/4" LSL (DR)2-7 1/4" LSL (DR)
F.D.(VERIFY LOCATION)
INSTALL SHWR.
NOTE:
HEAD 4-6" HIGHER
THAN STD. HT.
* INSULATE WALLS& CLG. AT GARAGE
NOTE:
PROVIDE WIRING & GAS
(FIELD VERIFY LOCATION)FOR FUT. HEATER
84" H.
RADON VENT
2'-0"
TYP.
8' CLG.
9' CLG.
GIRDER TRUSS
(3) 2x6
(3) 2x6(MATCH DR. HT.)2-11 7/8" LSL (FULL LENGTH)5460 SLIDER (MATCH DR. HT.)
2-2x10
9660 SLIDER 3'-1"4'-11"3068 MTL.F
U
L
L
L
I
T
E
2-7 1/4" LSL (DR) SMOKE
CM / 2'-0"TB
1
Temper
Temper
PFH PFH
6
8
8
5 7
07-00-BUYERPROJECT #
BUYER S/O
BUYER S/O
REVISIONS:
STARTED:
AGENT:X
XLOT 9, BLOCK 12, SUMMERS CREEK17873 GRAPHITE LN., LAKEVILLE, MN"SONOMA" 1640 VILLA HOMEMARK ELLIOTT HOMES3-12-21 SELECT
4-22-2021 PERMIT
OF
SHEET
SCALE: 1/4" = 1'-0"
SECTION1
5
N.T.S.
HOUSE / DECK CONNECTION DETAIL4
5
3/4" T & G FLOOR
NOTE: SUBFLOOR JOINTS SHALL BESTAGGERED FROM FLOOR TRUSS ORJOIST JOINTS
R=0.61
R=49.00
R=50.25
R=0.58
R=.061
TOTAL
TRUSSES - 24" OC
BLOWN INSULATION
INTERIOR AIR FILM
VAPOR BARRIER
15/32" OSB SHTG.
15# FELT
EXTERIOR AIR FILM
ICE AND SNOW SHIELD
30 YR. ARCH. ASPHALT SHINGLES
5/8" GYP BD
ALUM. SOFFIT & FASCIA
1/2" GYP BD
INTERIOR AIR FILM
TOTAL
SIDING PER SPECS
2x6 STUDS 16" OC
R=1.06
R=
R=
R=21.00
R=0.45
R=0.17
R=23.36
VAPOR BARRIER
FULL WALL BATT INSUL.
EXTERIOR AIR FILM
R=0.68
7/16" OSB SHTG.
8" AGGREGATE6 MIL POLY. LAP SEAMS 12"10"HEEL HT.1/2" GYP. SHEATHING ON GARAGE WALLS
5/8" TYPE 'X' GYP. BD. ON GARAGE CEILS.
18" FLOOR TRUSSES9'-1 1/8"T.O. SUBFLR.
T.O. PLATE
TRUSSES @ 24" O.C.
(DESIGNED BY MFR)
6
12
R-49 INSUL.10'-0"GARAGE
4" SLOPED CONC.
W/ REBAR PER
ENGINEERS REPORT
10'-0" POURED WALL
DRAIN TILE
10" POURED WALL
R-5 INSUL. ATINTERIOR FOUND.9'-9 1/8"O. BATH
OWNERS BDRM.
20x8 CONC. FTG.16x8 CONC. FTG.
16x8 CONC. FTG.
SPRAY FOAM RIM
8'-10" +/-FOUND. HELD IN 2"
FOR INSULATION TYP.
NOTE:
(INSUL. FLUSH w/ SHTG.)
CANT. 2x8 SILL PLT. 1-1/2"3 1/2" CONC. FLOOR 8 1/4"6"HEEL HT.6
12
8 1/4"2'-11"
NOTE: TOP HUNG TRUSSES
AT FRONT OF HOME
(9'-4" H. FDN. WALL)
SPRAY FOAM RIM
4"12"6 3/4" +/-1'-8 1/4"20x8 CONC. FTG.
T.O. FOUND.9'-0"R-5 THERMAX AT
INTERIOR FOUND.
AS REQUIRED
BDRM. #3 L.L. BATHCLST.
6
12
2'-0"12"GIRDER
GIRDER
27'-0"
JOIST
W/ 2-3/8" LAG BOLTS
ICE & WATER EXTENDS
5" UP SHEATING UNDER
INSTALL TOP OF LEDGER
3 5/8" BELOW TOP OF
3/4" SUBFLOOR (THIS
ALLOWS 5/4 X 4 THRESHOLD
AT DOOR)
HANGER
TREATED 2X10 LEDGER
RUN HOUSE WRAP BEHIND
LEDGER (LEAVE 6" TAIL
@ TOP, BOTTOM, & SIDES)
HOUSEWRAP
@ 24" O.C. -OR-
EMBED 2" MIN.8 INCHES O.C. MAX OR EQUAL,W/ "LEDERLOK" FASTENERS
CONT. 2X4 RIBBON
SPRAY FOAM INSUL. R-21 MIN.RIM BOARD
TREATED
JOIST
JOISTRIM
BD.SKIRT
1"
HOUSE
END OF DECK
HOUSE LATERAL LOAD
SIMPSON DTT1Z DECK-TO
CONNECTOR - (4) PER DECK
OR 8-10DX1 1/2" NAILS
6-SD#9X1 1/2" SCREWS
HDG WASHER OR SDWH
3/8" HDG LAG SCREW WITH
TIMBER-HEX HDG SCREW
(SHOWN) INTO TOP PLATE,
STUDS, OR HEADER
CONT. 2X8 RIBBON
DRAIN TILE
3/4" WASHED ROCK
CONTINUOUS
UNDER SLAB0'-16"
SILT FABRIC
FOUNDATION WALL
CONC. FTG.
4" DRAIN TILE
2
SCALE: NO SCALE5 TOP OF FDN.RIM DETAIL3
SCALE: NO SCALE5
2" RIGID INSULATION
R-10 w/ WATCHDOG
WATERPROOF COATING
AROUND HOUSE FOUND.
2" RIGID INSULATION
R-10 w/ WATCHDOG
WATERPROOF COATING
AROUND HOUSE FOUND.
2x8 TRTD. SILL
SHEATHING FLUSH
WITH INSULATION
NOTE:
FOUNDATION TO BE
HELD IN 2" FROM
SHEATHING & OUTSIDE
DIMENSIONS.
CANTED 1-1/2"
6 7
07-00-BUYERPROJECT #
BUYER S/O
BUYER S/O
REVISIONS:
STARTED:
AGENT:X
XLOT 9, BLOCK 12, SUMMERS CREEK17873 GRAPHITE LN., LAKEVILLE, MN"SONOMA" 1640 VILLA HOMEMARK ELLIOTT HOMES3-12-21 SELECT
4-22-2021 PERMIT
OF
SHEET
SCALE: 1/4" = 1'-0"
SECTION1
6
N.T.S.
PORTAL FRAME DETAIL2
6 N.T.S.
RADON DETAIL3
6
SIMPSON STRONG TIE Ab46z
HEADER
HURRICANE
CLIP ATTACHED
TO COLUMN
& BEAM
11 7/8" OSB STRINGER
W/ 2X4 BRACING
10 1/2" BULLNOSE LSL TREAD1X8 PINE S4S RISER
NOTE:
MAX RISE= 7 3/4"
MIN. RUN= 10"
6'-8" CLEAR HEADROOM
BATH BEDROOM #2 / OFFICEGREAT RM.
3/4" T & G FLOOR
NOTE: SUBFLOOR JOINTS SHALL BESTAGGERED FROM FLOOR TRUSS ORJOIST JOINTS
ALUM. SOFFIT & FASCIA
8" AGGREGATE6 MIL POLY. LAP SEAMS 12"
18" FLOOR TRUSSES9'-1 1/8"T.O. SUBFLR.
T.O. PLATE
TRUSSES @ 24" O.C.
(DESIGNED BY MFR)
R-49 INSUL.10'-0"W/ REBAR PERENGINEERS REPORT
9'-4" POURED WALL
DRAIN TILE
10" POURED WALL
R-5 INSUL. ATINTERIOR FOUND.
20x8 CONC. FTG.16x8 CONC. FTG.
SPRAY FOAM RIM
8'-10" +/-FOUND. HELD IN 2"
FOR INSULATION TYP.
NOTE:
(INSUL. FLUSH w/ SHTG.)
CANT. 2x8 SILL PLT. 1-1/2"
3 1/2" CONC. FLOOR
2" RIGID INSULATIONR-10 w/ WATCHDOG
WATERPROOF COATING
AROUND HOUSE FOUND.
PORCH10"HEEL HT.6
12
MECH. / STORAGEFAMILY ROOM
6
12
KITCHEN
8 1/4"4x4 TRTD. COL.
3
5
4" LEDGE
NOTE: TOP HUNG TRUSSES
AT FRONT OF HOME
(9'-4" H. FDN. WALL)
CONC. STOOP6 3/4" +/-4"SPRAY FOAM RIM1'-8 1/4"20x8 CONC. FTG.
T.O. FOUND.9'-0"2
5
R-5 THERMAX AT
INTERIOR FOUND.
AS REQUIRED
17R4 1/2"27'-0"
6x6 TRTD.
14" LP COL.
1'-2"4'-9"
3.25
12
3'-0"
OFFICE / BDRM. #4
SIMPSON STHD14 HOLD DOWN
SIMPSON LSTA36 STRAP ON INSIDE FACE OF WALL
5/8" ANCHOR BOLT
1/2" OSB SHEATHING
HEADER- SEE PLAN FOR SIZE
FASTEN SHEATHING TO HEADER WITH 8d COMMON ORGALVANIZED BOX NAILS IN 3" GRID PATTERN ASSHOWN, AND 3" O.C. IN ALL FRAMING MEMBERS TYP.
SHEATHING SPLICE (IF NEEDED) MUST BE
LOCATED WITH-IN 24" OF THE MID HEIGHTOF THE DOOR OPENING. PROVIDE 2-2X6BLOCKING BEHIND SPLICE
FASTEN TOP PLATE TO HEADER WITH2 ROWS OF 16d SINKER NAILS 3" O.C.
BLOCK BACK SIDE OF HEADER FLUSH WITH STUDSAT STRAP LOCATIONS
UNEXCAVATED SOIL
ALL SLABS WILL HAVE A MIN. 4" CLEAN AGGREGATE, COVERED BY
6 MIL POLY. THIS POLY WILL HAVE 12" LAP AT ALL SEAMS. ALL TEARS OR
PUNCTURES WILL BE SEALED OR COVERED BY POLY. ALL OPENINGS WILL BESEALED USING POLYURETHANE CAULK OR ELASTOMERIC SEALANT AT ALL OPNGS.
AN INSTALLED 3" GASTIGHT PVC PIPE WILL BE CONNECTED TO THE DRAIN
TILE SYSTEM. A "T" FITTING WILL BE INSTALLED WITH 10 L.F. EACH END
OF THE "T", OF PERFORATED PIPE, INTO THE DRAIN TILE SYSTEM. THE SHORTEST
ROUTE WILL BE USED TO EXIT THE ROOF SYSTEM, WITH A MAX. OF 2 90
DEGREE ELBOWS. IN UNCONDITIONED AREAS, THE RADON EXHAUST PIPE WILLBE INSULATED WITH AN R4 SLEEVE. THIS PIPE WILL BE LABELED "PASSIVE
RADON" AT ALL ACCESSIBLE LOCATIONS.
AT ROOF EXIT LOCATIONS, MAINTAIN A 10' DISTANCE TO ANY WINDOWLOCATION, 2' BELOW EXHAUST POINT AND ANY ADJACENT STRUCTURE. THE
LOCATION OF THE EXIT POINT, IN TRUSS AREA, WILL BE CLEAR OF ANY
OBSTRUCTIONS WITHIN 24" HORIZONTALLY AND 36" VERTICALLY. INSTALL AN OUTLET AND PULL CHORD LIGHT FOR FUTURE EXHAUST FAN
ADDITION.
SCALE: 1/4" = 1'-0"
MAIN FLR. ELECTRICAL PLAN
7 7
07-00-BUYERPROJECT #
BUYER S/O
BUYER S/O
REVISIONS:
STARTED:
AGENT:X
XLOT 9, BLOCK 12, SUMMERS CREEK17873 GRAPHITE LN., LAKEVILLE, MN"SONOMA" 1640 VILLA HOMEMARK ELLIOTT HOMES3-12-21 SELECT
4-22-2021 PERMIT
OF
SHEET
SCALE: 1/4" = 1'-0"
LOWER LEVEL ELECTRICAL PLAN SSTV
TV
W.P. FAN
G.F.I.P.S3S3INSTALLED
LTS.PENDANT
3SS
C/L
7'-6"3'-2"5'-9 1/2"SD
SD
GDO
G.F.I.P.SG.F.I.P.G.F.I.P.G.F.I.P.
W.P.SS
S 3S
SSDISP SS
TO LIGHT
S G.F.I.P.DW
GAS RANGEHOODVENT ABV.LNDRY.
DRYER WASHER(VENT TO OUTSIDE)REF.
KITCHEN
GREAT ROOM
FOYER
PORCH
O. BATH
GARAGE
O. CLST
BEDROOM #2 / OFFICE
OWNERS BDRM.
SMOKECM /
MUDRM.
DINING
SMOKE
CM / SS
S4S3S4S
SS SS G.F.I.P.S3
S3
S3SS
PANTRY BATH
3-SEASON PORCH
F.D.W.P.NOTE:
PROVIDE WIRING & GAS
(FIELD VERIFY LOCATION)
FOR FUT. HEATER
FANINSTALLED
3
S
(FIXTURE & INSTALL
WIRE & CAP OPNG.
BY BUYER)
(FIXTURE & INSTALL
WIRE & CAP OPNG.
BY BUYER)
(FIXTURE & INSTALL
WIRE & CAP OPNG.
BY BUYER)
LED TAPEUC. LITELED TAPEUC. LITELED TAPEUC. LITES
NOTE:
FL. OUTLET
C/L
C/LS
SMOKE
CM /
DUPLEX CONVENIENCE OUTLET
DUPLEX OUTLET ABOVE COUNTER
WEATHERPROOF DUPLEX OUTLET
HALF-SWITCHED DUPLEX OUTLET
DUPLEX OUTLET IN FLOOR
220 VOLT OUTLET
WALL SWITCH
THREE-WAY SWITCH
FOUR-WAY SWITCH
CEILING MOUNTED INCANDESCENT LIGHT FIXTURE
WALL MOUNTED INCANDESCENT LIGHT FIXTURE
RECESSED INCANDESCENT LIGHT FIXTURE
LIGHT FIXTURE WITH PULL CHAIN
TRACK LIGHT
FLOURESCENT LIGHT FIXTURE
EXHAUST FAN
EXHAUST FAN/LIGHT COMBINATION
CHIMES (OPTIONAL)
SMOKE DETECTOR
TELEPHONE (OPTIONAL)
TELEVISION (OPTIONAL)
THERMOSTAT
ELECTRIC METER
ELECTRIC PANEL
SPEAKER (OPTIONAL)
TV
T
M
CH
SD
P.C.
S
S
S
4
3
W.P.
ELECTRICAL KEY
DUPLEX OUTLET (GROUND FAULT PROTECTED)G.F.I.P.
RECESSED INCANDESCENT EYE BALL FIXTURE
CARBON MONOXIDE DETECTORCM
GARAGE DOOR
OPENER OUTLETGDO
FLUORESCENT
LIGHT PER SPEC
FAN/LIGHT COMBO
PREWIRE, PROVIDE
ADEQUATE
SUPPORT
4 BULB FIXTURE
3 BULB FIXTURE
200 AMP SERVICE
LIGHTING PACKAGE: T.B.D.
LINE TO DRYER: T.B.D.G.F.I.P.EXCH.AIR
SMOKE
CM /
S
S3S
TO LIGHT
A/C UNIT
w/ BRACKET
G.F.I.P.3
FURN
F.D.
WH
MECH.
BDRM. #3
FAMILY ROOM
L.L. BATH
SUMP
UNEXCAVATED
STORAGE
OFFICE / BDRM. #4
CLST.
H20
SD
SD
SSSSSS3SSS
S
S
TVABV. FP.NOTE:
TECH TUBE
G.F.I.P. SMOKECM /
WS
(2) MINI RECESS @ BAR
HUMIDIFIER
APRILAIRE
NOTE:
UC REFR.OUTLET FOR
BW
07-00-BUYERPROJECT #
BUYER S/O
BUYER S/O
REVISIONS:
STARTED:
AGENT:X
XLOT 9, BLOCK 12, SUMMERS CREEK17873 GRAPHITE LN., LAKEVILLE, MN"SONOMA" 1640 VILLA HOMEMARK ELLIOTT HOMES3-12-21 SELECT
4-22-2021 PERMIT
6-7-2021 REV. #1
N.T.S.
MAIN LEVEL BRACEWALL2
BW
N.T.S.
BRACEWALL DETAILS3
BW
GARAGE PORTAL FRAMING PER BUILDING CODE IRC R602.10.6.4
BRACED WALL METHOD CS-WSP4'-0" PANELBRACED WALLLINE 1BRACED WALLLINE ABRACED WALLLINE 23'-5" PANEL
6'-0" GYP. PANEL
BRACED WALLLINE B
BRACED WALL
LINE C
3'-5" PANEL
3'-2" PANEL3'-2" PANEL 3'-5" PANEL
4'-0" PANEL4'-0" PANEL4'-0" PANEL4'-0" PANEL4'-0" PANEL4'-0" PANEL4'-0" PANEL4'-0" PANEL8'-0" GYP. PANEL
8'-0" GYP. PANEL
3'-3" PANEL 4'-2" PANEL
1'-4" PANEL
LNDRY.
KITCHEN
GREAT ROOM
FOYER
PORCH
O. BATH
GARAGE
O. CLST
BEDROOM #2 / OFFICE
OWNERS BDRM.
MUDRM.
DINING
PANTRY BATH
3-SEASON PORCH
2'-2" PANEL2'-2" PANEL
MIN. 3''x11 1/4'' NET HEADER(STEEL HDR. PROHIBITED)
EXTENT OF HEADER W/ SINGLE PORTAL FRAME
ONE BRACED WALL PANEL
10'-0'' MAX. HEIGHT(TOP OF HDR.)TOP OF FDN.
TOP OF CONC FLOOR AT OPENING
MIN. 2-2x4 FRAMING
STUD POST
CONTINUOUS HEADER WITH DOUBLE PORTAL FRAMES
TWO BRACED WALL PANELS
6' TO 18' OPENING
FASTEN TOP PLATE TO HEADER W/ 2ROWS OF 16d SINKER NAILS @ 3'' O.C. TYP.
1000 LB. STRAP OPPOSITE SIDE OF SHEATHING
FASTEN SHEATHING TO HEADER W/ 8d
COMMON OR GALV. BOX NAILS IN 3'' GRIDPATTERN SHOWN AND 3'' O.C. IN ALLFRAMING(STUDS, BLOCK'G AND SILLS)TYP.
MIN. WIDTH PER TABLE R602.10.5
3/8'' MIN. WOOD STRUCTURAL PANEL SHEATH'G.
MIN. 2-2x4
MIN. 4200 LB. TIE DOWN DEVICE(EMBED INTOFOUNDATION AND NAILED INTO FRAMING
MIN. (2) 1/2'' DIA. ANCHOR BOLT INSTALLED PER R403.1.6
W
SEE LEFT FORTYP. PORTALFRAME CONST.
FOR A PANEL SPLICE(IF NEEDED) PANEL
EDGES SHALL BEBLOCKED AND OCCURWITHIN 24'' OF MID-
HEIGHT. ONE ROW OFTYP. SHEATH'G. TOFRAMING NAILING IS
REQUIRED.IF 2x4 BLOCK'G. IS USEDTHE 2x4'S MUST BE NAILED
TOGETHER W/ 3 16dSINKER NAILS
W/ 2''x2''x3/16'' PLATE WASHER12'-0'' MAX. HEIGHT(TOP OF WALL)FULL HEIGHT OF WALL - SEE TO RIGHT FOR SPLICESPONY WALL HT.EXTENT OF HEADER
TENSION STRAP PERTABLE R602.10.6.4 (ONOPPOSITE SIDE OF
SHEATHING
ANCHOR BOLTSPER SECTION
R403.1.6
BRACED WALL LINECONTINUOUSLYSHEATHED WITH
WOOD STRUCTURALPANELS
TOP OF FLOOR AT OPENING
FLOOR FRAMING ASSEMBLY PER PLAN W/ WOOD STRUCTURAL PANEL SHEATHING
TOP OF FLOOR AT OPENING
FLOOR FRAMING ASSEMBLY PER PLAN
WOOD STRUCTURAL PANEL SHEATHING
TO TOP OF BAND OR RIM JOIST
NAIL SOLE PLATE TO FLR
FRAMING PERTABLE R602.3(1)
(2) FRAMING ANCHORS APPLIED ACROSSSHEATHING JOINT WITH A CAPACITY OF
670# IN HORIZ. AND VERT. DIRECTIONS
SEE LEFT FOR
TYP. PORTALFRAME CONST.
ON CONCRETE FOUNDATION
ON RAISED WOOD FLOOR - FRAMING ANCHOR OPTION
TOP OF FLOOR AT OPENING
FLOOR FRAMING ASSEMBLY PER PLAN W/ WOOD STRUCTURAL PANEL SHEATHING
TOP OF FLOOR AT OPENING
FLOOR FRAMING ASSEMBLY PER PLAN
WOOD STRUCTURAL PANEL SHEATHINGTO TOP OF BAND OR RIM JOIST
NAIL SOLE
PLATE TO FLRFRAMING PERTABLE R602.3(1)
SEE LEFT FORTYP. PORTALFRAME CONST.
ON RAISED WOOD FLOOR - OVERLAP FLOOR OPTION
MIN. OVERLAP 9 1/4''WOOD STRUCTURAL PANEL SHEATHING
CONTINUOUS OVER BAND OR RIM JOIST
MIN. OVERLAP 9 1/4''ATTACH TO RIM/BAND JOIST W/ 8d
COMMON NAILS AT 3'' O.C. AS SHOWN
DBL TOP PLATE
BOTTOM PLATE
STUDS AT 16'' O.C.
W/ 6d NAILS @ 6'' O.C.
4'-0"8'-0'' MIN., SEE PLANINTERMEDIATE
6''3"W/ 6d NAILS @ 3'' O.C.
EDGES NAILED
J2J2J2J2J2J2J2J2J2J2F1-SGJ6
J7
J9
J9
J9
J9
J9
J9
J9
J9
J9
J9
J9
J8
J8
J8
J8
J8
J8
J8
J8
J
10
J11J11J12
J13
J14
J15
J16
J8
J8
J8
J8
J8
J8
J8
J8
J8
J8
J8
J8
J8
J8
J8 D5D6D7PB2PB3PB3D8E1E1E2PB3PB3PB3PB3B1-GE
B2
B2
C1-GR
C2
C3
J17
J17
J17
J17
J17
J18
J19
J9
J9
J9
J9E2E3E4E5-GRPB4G1-GE
G2
G2
G2
G2
G3
J1D1-GRD2D3D4PB1A1-GR
J20J20J20PG1PG5
PG4
PG3PG2V18
V9
V8-GE
V10
V11
V12
V13 J3J4J4J5J5J5J5C4-GR
V14
V15
V16
V17
V1
V2
V3
V4
V5
V6
V7
40'
5'11"4
5'11"4
6'10'12'6"13'14'6"4'33'29'6'52'10'2'19'21'
TRUSS END MARKED WITH (X) CORRESPONDSWITH THE LEFT END ON THE TRUSS DRAWINGS.
BOX VAULTS ARE MADE 1 1/2" LARGER FOR2x4 FRAMING.
ROOF TRUSS LAYOUT LUS24 HANGERS TYPLUS24 HANGERS TYPLUS24 TYP
DORMER
HHUS26-2HUS26 HANGERS TYP12" RAISED CEILINGHUS26 HANGERS TYPHHUS26-2
Created by BAM version 052009
New Construction Energy Code Compliance Certificate
Place your
logo here
Per N1101.8 Building Certificate. A building certificate shall be posted in a permanently visible location inside
the building. The certificate shall be completed by the builder and shall list information and values of
components listed in Table N1101.8.
Date Certificate Posted
Mailing Address of the Dwelling or Dwelling Unit City
17873 Graphite lane lakeville
Name of Residential Contractor MN License Number
Mid State Plumbing & Htg PM64995
THERMAL ENVELOPE RADON SYSTEM
Insulation Location
Total R-Value of all Types ofInsulationType: Check All That Apply X Passive (No Fan)Non or Not ApplicableFiberglass, BlownFiberglass, BattsFoam, Closed CellFoam Open CellMineral FiberboardRigid, Extruded PolystyreneRigid, IsocynurateActive (With fan and monometer or
other system monitoring device)
Other Please Describe Here
Below Entire Slab
Foundation Wall R-15 x Exterior 2" CertiStud -- Interior 3/4" Thermax
Perimeter of Slab on Grade R-10 x
Rim Joist (Foundation)N/A
Rim Joist (1st Floor+)N/A Interior
Wall R-21 x
Ceiling, flat R-49 x Attic
Ceiling, vaulted R-38 x
Bay Windows or cantilevered areas N/A Interior
Bonus room over garage N/A Exterior & Interior
Describe other insulated areas
Windows & Doors Heating or Cooling Ducts Outside Conditioned Spaces
Average U-Factor (excludes skylights and one door) U: 0.29 X Not applicable, all ducts located in conditioned space
Solar Heat Gain Coefficient (SHGC):0.28 R-value
MECHANICAL SYSTEMS Make-up Air Select a Type
Appliances Heating System Domestic Water Heater Cooling System X Not required per mech. code
Fuel Type Natural Gas Natural Gas Electric Passive
Manufacturer Bryant Bradford White Bryant Powered
Model 912S MITW50 113A Interlocked with exhaust device.
Describe:
Rating or Size Input in
BTUS:42973 Capacity in
Gallons:
50 Output in
Tons:2 X RenewAire Exchanger EV90
Structure's Calculated Heat Loss: Heat
Gain:19,737 Basement and Duct in Floor trusses
Efficiency
AFUE or
HSPF%
92.00% SEER: 13
Calculated
cooling load:
19,737 Cfm's
" round duct OR
Mechanical Ventilation System " metal duct
Combustion Air Select a Type
Not required per mech. code
Select Type X Passive
Heat Recover Ventilator (HRV) Capacity in cfms:Low: Variable High:Other, describe:
x Energy Recover Ventilator (ERV) Capacity in cfms:Speed High: Location of duct or system:
Continuous exhausting fan(s) rated capacity in cfms:6 " 0
Location of fan(s), describe: Mechanical room in Garage Cfm's
Capacity continuous ventilation rate in cfms:73 CFM X " round duct OR
Total ventilation (intermittent + continuous) rate in cfms:145 CFM " metal duct
NEW RESIDENTIAL CONSTRUCTION SWPPP VERIFICATION
This form must be completed and submitted with all new residential permit applications.
A National Pollutant Discharge Elimination System (NPDES) Construction Stormwater Permit is
required for “Construction activity that results in land disturbance of equal to or greater than one (1)
acre or if a project is part of a common plan of development that will ultimately disturb greater than
one (1) acre,” (NPDES Permit, Section 1.2).
Project Site Address: _____________________________________________________________________
Company Name: _________________________________________________________________________
*Primary Company Contact: _________________________________________________________________
*Should a site be deemed noncompliant, this individual will be notified
Phone #: ____________________________ Email: ______________________________________________
If you are not covered under a NPDES Construction Stormwater Permit administered by the
Minnesota Pollution Control Agency (MPCA), an erosion and sediment control plan MUST be
approved as part of the residential building permit application.
“Permittees must ensure a trained person will inspect the entire construction site at least once every
seven (7) days during active construction and within 24 hours after a rainfall event greater than ½
inch in 24 hours,” (NPDES Permit, Section 11.2).
The City of Lakeville reserves the right to request weekly inspection logs. The City of Lakeville may
issue a STOP WORK ORDER; withhold building inspections; or, draw on securities/escrows to
bring the site into compliance with the NPDES Construction Stormwater Permit (MN R 100001) or
erosion and sediment control plan.
Contact information of person CERTIFIED to provide weekly onsite erosion and sediment control
inspections and corrective actions:
Name: ____________________________________ Company: ___________________________________
Phone # (24 hr Contact): ______________________ Email: ______________________________________
Entity that Provided Training: __________________________ Certification Expiration Date: ____________
NOTE: Prior to any land-disturbing activity, all erosion and sediment controls must be installed
I understand the above information to be accurate and I have read, understood, and accepted all terms and conditions of the NPDES Permit (MN R 100001).
Signature: ________________________________________________ Date:_________________________
Contact the City of Lakeville with questions at erosion@lakevillemn.gov or 952-985-4500
Nick Reimler
X05/25/21
KP