Loading...
HomeMy WebLinkAboutLA193343 - 17971 Gresford Ln Permit PackRESIDENTIAL BUILDING PERMIT APPLICATION CITY OF LAKEVILLE BUILDING INSPECTIONS DEPARTMENT 20195 HOLYOKE AVENUE LAKEVILLE, MN 55044 952-985-4440 Office Use Only __________________ Permit Number ___________________ Received By ___________________ Date Received ___________________ Fee Total SITE ADDRESS: MAILING ADDRESS: CITY: STATE: ZIP: JOB DESCRIPTION:__________________________________ MASTER PLAN: (Number or Address)____________________ LIST OTHER STRUCTURES ON PROPERTY:_______________________________________________________________ ESTIMATED VALUATION: PROPOSED START DATE: END DATE: (New Residential Only): LEGAL DESCRIPTION: LOT: _____ BLOCK: _____ SUBDIVISION: APPLICANT IS: RESIDENT OWNER CONTRACTOR EMAIL NEW MODEL HOME: YES NO (IF YES – ADMINISTRATIVE PERMIT REQUIRED) PLEASE FILL OUT THE FOLLOWING COMPLETELY (All Contractor information must be as listed on State License) RESIDENT OWNER NAME:_______________________________________________________________________________ HOME PHONE #:_____________________________ CELL PHONE:___________________________ GENERAL CONTRACTOR Homeowner Contractor CONTRACTOR:_______________________________________________________________________ LICENSE #:BC______________ LEAD CERTIFICATE#_______________ (PRE 1978 STRUCTURE) OFFICE PHONE #:_____________________________ CELL PHONE:___________________________ ADDRESS:____________________________ CITY:________________ ST:______ ZIP:____________ PLUMBING WORK Homeowner Contractor CONTRACTOR:__________________________________________LICENSE #: PM______________ OFFICE PHONE #:_____________________________ CELL PHONE:___________________________ ADDRESS:____________________________ CITY:________________ ST:______ ZIP:____________ MECHANICAL WORK Homeowner Contractor CONTRACTOR:________________________________________ _______________________________ OFFICE PHONE #:_____________________________ CELL PHONE:___________________________ ADDRESS:____________________________ CITY:________________ ST:______ ZIP:____________ BOND #:_______________________________________ EXPIRATION DATE____________________ SEWER/WATER CONTRACTOR New Construction Only NAME:________________________________________________ ______________________________ HOME PHONE _____________________________ CELL PHONE:______________________________ BOND #:_______________________________________ EXPIRATION DATE____________________ INTEREST EARNINGS ON THE ESCROW ACCOUNTS, IF ANY, ARE RETAINED BY THE CITY TO OFFSET THE ADMINISTRATIVE COSTS ASSOCIATED WITH PROCESSING THE ESCROW APPLICATION AND REFUND. I HEREBY APPLY FOR A BUILDING PERMIT AND I ACKNOWLEDGE THAT THE INFORMATION ABOVE IS COMPLETE AND ACCURATE; THAT THE WORK WILL BE IN CONFORMANCE WITH THE ORDINANCES AND CODES OF THE CITY AND WITH THE STATE BUILDING CODE, THAT I UNDERSTAND THIS IS NOT A PERMIT AND WORK IS NOT TO START WITHOUT A PERMIT AND THAT THE WORK WILL BE IN ACCORDANCE WITH THE APPROVED PLAN. NAME OF APPLICANT (Please Print)DATE APPLICANT’S SIGNATURE: www.lakevillemn.gov Nick Reimler RESIDENTIAL BUILDING PERMIT APPLICATION PAGE 2 OFFICE USE ONLY BUILDING PERMIT TYPE REQUIRED INSPECTIONS SINGLE FAMILY DWELLING BUILDING DUPLEX AS BUILT TOWNHOUSE UNITS BUILDING FINAL DETACHED TOWN HOUSE UNIT DECK FOOTING CONDO FIREPLACE ACESSORY BUILDING FOOTING REROOF FOUNDATION RESIDE FRAMING PORCH FRAMING GARAGES INSULATION RES ADDN/REPAIR/RMDL DECK PORCH GARAGES LATH LOWER LEVEL FINISH LOWER LEVEL FINAL ADDITION OTHER FOUNDATION ONLY PORCH FOOTING MISCELLANEOUS POURED WALL DEMO SEPTIC TANK REMOVAL MOVED SITE MECHANICAL CITY BUILDING VALUATION: $AIR TEST FINAL BUILDING PERMIT FEES ROUGH-IN $PERMIT FEE PLUMBING $PLAN CHECK FINAL $SURCHARGE ROUGH-IN $METRO SAC METER SIZE $CITY WATER HOOKUP UNIT PRESSURE REDUCING VALVE $CITY SEWER HOOKUP UNIT SEWER/WATER $LANDSCAPE ESCROW SEWER/WATER $TREE ESCROW FINAL $MISC ESCROW STREET DRAINTILE $PLUMBING BUILDING INFORMATION $MECHANICAL TYPE OF CONSTRUCTION $SEWER WATER ZONING $OTHER CODE EDITION $TOTAL FIRE SUPPRESSION SYSTEM OCCUPANCY GROUP APPROVED BY: BUILDING INSPECTOR: Date: PLUMBING/MECHANICAL INSPECTOR: Date: COMMENTS: 20195 Holyoke Avenue, Lakeville, MN 55044 952-985-4400  952-985-4499 fax www.lakevillemn.gov Sewer & Water Tie Card Address:________________________________________ Contractor:______________________________________ Permit Number:__________________________________ Final Date:________________ Street Drain-Tile:______ Size of Water Service: 1” Comments: AIRTEST SANITARY OVER 20’/2 FITTINGS THIS CARD MUST BE COMPLETED AND ON-SITE AT TIME OF SEWER & WATER INSPECTION 1 7SCALE: 1/4" = 1'-0" FRONT ELEVATION GENERAL NOTES: 1. ALL DOOR AND WINDOW HEADERS TO BE S.P.F. #2 OR BETTER, SEE PLANS FOR SIZES. 2. HOUSE TO BE BUILT PER CURRENT I.R.C. CODES. 3. VERIFY GRADES AND ADJUST FOUNDATION/FOOTING STEPS AS NEEDED. 4. SEE PLANS FOR CEILING HEIGHTS 5. 4' HIGH POURED FDN. WALLS STD. 6. FLOOR PLAN DIMENSIONS ARE TO FACE OF FRAMING AND FOUNDATION. 7. ALL TRADES & SUPPLIERS TO REVIEW & VERIFY INFORMATION PERTINENT TO THEIR WORK AND NOTIFY CONST. OF ANY DISCREPANCIES PRIOR TO CONSTRUCTION. 8. NOTED CABINET SIZES ARE +/- AND TO BE FIELD VERIFIED. 9. TRADES TO VERIFY BASE AND TRIM SIZE PRIOR TO CONSTRUCTION. 10. ALL WALLS MORE THAN 10' H. TO BE S.P.F. #2 OR BETTER. 11. EXTERIOR ELEVATIONS ARE CONCEPTUAL ONLY: HOME SITE, FILL AND TOPOGRAPHY WILL DICTATE ACTUAL GRADES AND MAY VARY FROM THOSE SHOWN ON THE PLAN. 12. NOTE: SUBFLOOR JOINTS SHALL BE STAGGERED FROM FLOOR TRUSS OR JOIST JOINTS OF SHEET 07-00-BUYERPROJECT # BUYER S/O BUYER S/O REVISIONS: STARTED: AGENT:X X"HAMPTON" 1660 VILLA HOMEMARK ELLIOTT HOMES4-10-21 SELECTLOT 10, BLOCK 6, SUMMERS CREEK17971 GRESFORD LN., LAKEVILLE, MN6-3-21 PERMIT 7-28-21 REV. PERMIT SCALE: 1/8" = 1'-0" ROOF PLAN SEE ROOF PLAN FOR ROOF PITCHES AND OVERHANGS 25'-9"CONC. PORCH 6:12 ALUM. SOFFIT & FASCIA 30 YR. ARCH. ASPHALT SHINGLES 2x OVER 8" TRIM 8" LP TRIM4'-6" LP SMARTSIDE LAP SIDING (4")9'-1 1/8"T.O. SUBFLR. T.O. PLATE 1'-8 1/4"T.O. FDN.6" TRIM 6" TRIM 9'-9 1/8"@ GARAGE T.O. PLATE 12 12 12 12 1'-6"7'-2 1/2"T.O. 3048 SH STAT. (BLACKENED) STONE WHERE INDICATED 12" CANT. 10" TRIM C/L T.O. FDN.7'-11"@ DORMERT.O. PLATE 10'-6"FP CHASE 24"x60" FALSE LP PANEL8:12 8:12 6:12 6" TRIM 6" TRIM 8" LP TRIM12" TRIM 12" TRIM 6" TRIM6"LP PANEL 12 12 12 12 12 12 5'-0"STONE CAP STONE TOTAL: 118.02 SQ. FT. (41.03%) TOTAL SQ. FT.: 287.66 MATERIAL CALCULATIONS: FRONT ELEV. LP TRIM / PANEL: 169.64 SQ. FT. (58.97%) STONE TOTAL: 145.36 SQ. FT. (7.27%) TOTAL SQ. FT.: 1998.89 MATERIAL CALCULATIONS: ALL ELEV. LP LAP SIDING TOTAL: 1326.43 SQ. FT. (65.35%) LP TRIM / PANEL: 551.25 SQ. FT. (27.38%)8" LP TRIM8" LP TRIM8" LP TRIM8" TRIM 12" TRIM LP PANELLP PANELGLS.GLS.GLS.GLS. NOTE: SEE ROOF TRUSS LAYOUT FOR TRUSS DIRECTION AND GIRDER LOCATIONS PROVIDED BY MANUFACTURER PROVIDE ATTIC VENTILATION EQUAL TO 1/150th ATTIC AREA. IF 50% OR MORE IS PROVIDED IN UPPER PORTION OF THE ROOF AND REMAINDER IS PROVIDED IN SOFFIT VENTS, IT MAY BE REDUCED TO 1/300th ATTIC AREA. ICE AND WATER SHIELD 6'-0" IN FROM EAVES 1'-6" ON EACH SIDE OF VALLEY WHERE WALLS MEET ROOF ICE & WATER SHIELD SHOULD RUN UP WALL 1'-6" AND OUT FROM WALL 1'-6" NOTE: NOTE: NOTE: SADDLE1'-6"2'-0"12:12RIDGERIDGE 1'-0" 1'-6"6:126:126:1212:12 2'-0"2'-0"4'-0"6:1212:12 12:128:1212:12 12:12 8:1212:12 1'-6" 1'-6"1'-6"1'-6"1'-6"2'-0"6:1212:12 12:12 1'-6"1'-6"GUTTERS PER SPECS NOTE: GUTTERS PER SPECS NOTE: Concept Approval ONLY Subject to Field Inspection Inspector Date 2020 MN Bldg Code 07/29/2021dmathews EXTERIOR ELEVATIONS ARE CONCEPTUAL ONLY: HOME SITE, FILL AND TOPOGRAPHY WILL DICTATE ACTUAL GRADES AND MAY VARY FROM THOSE SHOWN ON THE PLAN.2 7 07-00-BUYERPROJECT # BUYER S/O BUYER S/O REVISIONS: STARTED: AGENT:X X"HAMPTON" 1660 VILLA HOMEMARK ELLIOTT HOMES4-10-21 SELECTLOT 10, BLOCK 6, SUMMERS CREEK17971 GRESFORD LN., LAKEVILLE, MN6-3-21 PERMIT 7-28-21 REV. PERMIT OF SHEET SIDE ELEVATION SCALE: 3/16" = 1'-0" REAR ELEVATION SIDE ELEVATION SCALE: 3/16" = 1'-0" SCALE: 3/16" = 1'-0" @ GARAGE 9'-9 1/8"T.O. FDN. ALUM. SOFFIT & FASCIA A/C UNIT T.O. PLATE 9'-1 1/8"T.O. SUBFLR. T.O. FDN.1'-8 1/4"10" TRIM LP CORNERS 4" LP TRIM @ WDWS. & DOORS TYP. 12 6 12 6 LP SIDING PER SPECS T.O. PLATE SEE ROOF PLAN FOR PITCHES AND OVERHANGS 7'-8"@ DORMER T.O. PLATE 12:12 12:12 12 6 12 8 LP PANEL 2'-0" 12 6 12:12 SCREENSCREEN10" TRIM T.O. PLATE 9'-1 1/8"T.O. SUBFLR. T.O. FDN.1'-8 1/4"LP CORNERS 4" LP TRIM @ WDWS. & DOORS TYP. SEE ROOF PLAN FOR PITCHES AND OVERHANGS ALUM. SOFFIT & FASCIA 6:12 LP SIDING PER SPECS 12" CANT. 12 12 12 12 LP PANEL12 12 6:1212 12 SCREENSCREENSCREEN12:12 ALUM. SOFFIT & FASCIA LP PANEL 12 6 T.O. PLATE 9'-1 1/8"T.O. SUBFLR. T.O. FDN.1'-8 1/4"12 6 10" TRIM 12" CANT.LP CORNERS 4" LP TRIM @ WDWS. & DOORS TYP. LP SIDING PER SPECS FP VENT SADDLE SEE ROOF PLAN FOR PITCHES AND OVERHANGS 12:12 12:12 12 6 12 8 12 8 LP PANELLP PANELSTONE 12:12 12 6 SCREENSCREEN SCALE: 3/16" = 1'-0" FOUNDATION PLAN 3 7 07-00-BUYERPROJECT # BUYER S/O BUYER S/O REVISIONS: STARTED: AGENT:X X"HAMPTON" 1660 VILLA HOMEMARK ELLIOTT HOMES4-10-21 SELECTLOT 10, BLOCK 6, SUMMERS CREEK17971 GRESFORD LN., LAKEVILLE, MN6-3-21 PERMIT 7-28-21 REV. PERMIT OF SHEET A/C UNIT w/ BRACKET FURN F.D. WH MECH. / STORAGE WS 30 6 8 2668 BDRM. #3FAMILY ROOM L.L. BATH 36" V.CONC. H.B. H.B. 2" LEDGE TYP. TO PROVIDE ADD'L. SUPPORT FOR FILL FOR SLAB TYP. FND @ HOUSE / GARAGE 10" POURED CONC. W/ 4" LEDGE INSIDE 20X8 CONC. FTG. 2" FOAM SUMP H20 4" LEDGE2" FOAM TYP. FND @ STOOP 10" POURED CONC. W/ 4" LEDGE INSIDE 20X8 CONC. FTG. UNEXCAVATED 2" NOTE: NO DRYWALL @ CLG. REQUIRED IN THIS AREA - FIRE BLOCK @ PERIMETER OF OPNG. (80 SQ. FT. MAX.) 6"2" RADON VENT TO TERMINATE IN SUMP BASKET 6" 4" 10" GARAGE/HOUSE COMMON WALL 2x8 TREATED SILL OVERHANG FDN. 2'' GARAGE SLAB 2'' RIGID INSUL. MAIN FLR SEE FIRST FLOOR FOR GARAGE DOOR SIZE FOR M.O. NOTE: 4" LEDGE 6"2"CARPET CARPET 3 1/2'' CONC. FLOOR TYP. FND @ HOUSE 8" POURED CONC. (8'-4" H.) 20X8 FTG REBAR PER CODE TYP. FND @ BRG. WALL 2x4 STUDS 16" O.C. 16X8 FTG REBAR PER CODE 4" CONC. CURB KITCHEN ISLAND ABV. FLR. TRUSS CO. 246818" FLR. TRUSSES19.2" O.C. SPACING(11'-10"x12'-0")(25'-6"x12'-0") RADON VENT NOTE: EXTERIOR HOUSE AND GARAGE/HOUSE COMMON FDN. WALLS TO BE HELD 2'' IN. DIMENSIONS SHOWN ARE TO FACE OF 2'' EXTERIOR RIGID INSULATION & FRAMING ABOVE TO BE 5000 PSI CONC.NOTE: ALL FOOTINGS 2'' MIN. 2x8 TREATED SILL-OVERHANGFDN. 1 1/2''8" 2" TYP. SIDE WALL DETAIL FOUND. HELD IN 2" FOR INSULATION NOTE: (TYP.)2"2"2"2" 8'-4" POURED FDN. APPROX. 1,660 NET SQ. FT. FILL FOR SLAB 40'-0" 14'-6"12'-0"58'-0"6'-0"52'-0"58'-0"4'-0"29'-0"25'-0"15'-8"13'-4"8'-6 1/2"12'-0"5'-0"2'-0"18'-0"40'-0" 19'-0"21'-0" 8'-6" 19'-5 1/2" & HOUSE/PORCH 11'-3"9'-9"18" FLR. TRUSSES19.2" O.C. SPACING3-9 1/2" LSL (DR) FOUND. HELD IN 2" FOR INSULATION NOTE: (TYP.) 32x60 FBGLS. TUB / SH2x10 TRTD. JOISTS16" O.C. SPACING3-2x12 TRTD. (FL) SMOKECM / 12" CANT. ABV.9'-4" H. FOUND. WALL @ FRONT OF HOME NOTE: 9'-4" H. FOUND. WALL@ FRONT OF HOME NOTE: w/ TOP HUNG TRUSSES w/ TOP HUNG TRUSSES 9'-4" H. FOUND. WALL @ FRONT OF HOME NOTE: w/ TOP HUNG TRUSSES21'-11"11'-10"18'-3"9'-1 1/2"10'-4" 30"x30" CONC.PAD FTG. 6x6 COL. 28" DIA. FROST FOOTING (60" D.) 6x6 TRTD. COL. 2-2x10 (DR) 3-9 1/2" LSL (DR) 2 4 6 810'-0"UP 16 R (10" T., 7-3/4" MAX. R.) 24685'-10"2-2x10 (DR) 2-2x10 (DR)18" FLR. TRUSSES19.2" O.C. SPACING18'-3"8'-8 1/2"3'-10 1/2"2'-10"2'-8"3'-8" 4'-2 1/2"7'-2"4'-3 1/2"4'-3 1/2"13'-7"13'-4 1/2"9'-0 1/4"12'-1" w/ WD. CAPSLOPED WALL 2x6 BRG. WALL 12'-0" 20"x8" CONT. CONC. FTGS. REBAR PER CODE 42" H. x 8" W. POURED CONC. FOUNDATION WALL 2" RIGID INSULATION 1 TRTD. PLATE 6042 SLIDER @ 7' 7'-6"12'-10"12'-7"7'-1" 2-9 1/2" LSL2-9 1/2" LSL 6042 SLIDER @ 7'8042 SLIDER @ 7' 3-9 1/2" LVL 4'-8"3'-1 1/2"3'-0 1/2"R&SHR&SHR&SHCARPET CARPET 4'-0 1/4" VIN. FLR. * HUMIDIFIER 7' H. SOFFIT 13'-2" (4) SH.2'-0"3'-0" 15'-7"3'-6"WOOD LEDGE AT LOOKOUT APPROX. 906 FIN. SQ. FT. BWPs Above UFER Ground -Provide 20' Rebar in footing and stub up near electrical service panel. Smoke Smoke CO SCALE: 3/16" = 1'-0" MAIN FLOOR PLAN 4 7 07-00-BUYERPROJECT # BUYER S/O BUYER S/O REVISIONS: STARTED: AGENT:X X"HAMPTON" 1660 VILLA HOMEMARK ELLIOTT HOMES4-10-21 SELECTLOT 10, BLOCK 6, SUMMERS CREEK17971 GRESFORD LN., LAKEVILLE, MN6-3-21 PERMIT 7-28-21 REV. PERMIT OF SHEET P.H.TBTR DW GAS RANGEMICRO ABV. FLUSH OH. LNDRY. DRYERWASHER 9' CLG. / LVP UPPER CAB. (VENT TO OUTSIDE) NOTE: - STD. BASE & CASING TO BE PRINCETON - 1/2 WALL w/ WD. CAP & INVERTED CASING NOTE: 2X6 EXT. WALLS U.N.O. 2X4 INT. WALLS U.N.O. - 42" UPPER CABINETS DOOR ROUGH OPENINGS: 83" HEIGHT 82" OVER VINYL CERAMIC TILE & WOOD 82" OVER CARPET SRO = SHEET ROCKED OPNG BIFOLD DOORS: PREHUNG UNITS: 2" WIDER THAN DOOR (EXAMPLE: 2668 ) 1 3/8" WIDER THAN DOOR FINISH SIZE NOTED ON PLAN CO = CASED OPENING ( WOOD ) (EXAMPLE: 2668 ) FINISH SIZE NOTED ON PLAN RO. 1 1/2" WIDER, 83" HIGH R.O. 1" WIDER, 83" HIGH PER SPECS DRIVEWAY NOTE: REF. KITCHEN 9' CLG. / LVP13'-8" x 9'-3" (128 SQ. FT.) 3-14" LVL GREAT ROOM 9' CLG. / LVP FLR. GAS F.P.12'-6" x 13'-0" (170 SQ. FT.) / LVP 42" W. CONC. SIDEWALK FIBRGLS. 60x36 SHWR. UNIT 5'-0"210682-11 7/8" LSL FOYER 9' CLG. / LVP 6'-11" x 7'-1" (51 SQ. FT.) O. BATH 9' CLG. / VIN. 2x6 WALLS U.N.O. 4" SLOPED CONC. GARAGE CEIL. TO BE 5/8" TYPE 'X'GYP. BD. WALLS TO BE 1/2" GYP.SHEATHING. ALL WALLS & CEILINGS TOHAVE ONE COAT FIRETAPE GARAGE SLOPE CONC.6'x8' PATIO DR. 16'x7' O.H.D. w/ WDW.R.O. 16'-1" FRAMING O. CLST 8' CLG. / CARPET SHELVING BY 82" +/- VAN. BATH BEDROOM #2 / OFFICE 26683648 SH @ 8'9' CLG. / CARPET w/ WD. CAPMANUF. TRUSSES24 O.C.(12'-3"x10'-6") EXTERIOR FLOOR PLAN DIMENSIONS ARE TO OUTSIDE OF SHEATHING, INTERIOR DIMENSIONS ARE TO FRAMING. NOTE: ALL DRS/ WIN.'S REQUIRE 4" ON SIDES FOR CASING NOTE: 2X6 EXT. WALLS U.N.O.2X4 INT. WALLS U.N.O. HEADER SPANS: UP TO 4'-11'' = 1 TRIMMER 5'-0'' AND BIGGER = 2 TRIMMERS UNLESS NOTED OTHERWISE INDICATES LOCATION OF SOLID BRG. (131 SQ. FT.) OWNERS BDRM. TRAY VAULT / CARPET (15'-6"x12'-6") (198 SQ. FT.) SMOKECM / SD 2 - 4072 SH @ 8' DN 16 R (10" T., 7-3/4" MAX. R.) 8/0 H. SOFFIT ATTICACCESSAPPROX. 462 SQ. FT. MUDRM. 9' CLG. / LVP APPROX. 9'-0'' CLG. @ MAIN LEVEL APPROX. 1,660 SQ. FT.3068 MTL.3080 MTL.2468 PKT. DR. R&SH R&SH9' CLG. / CARPET 9' CLG. 8' SOFFIT 2868LIN.CAB. 30682 - 4072 SH @ 8'27" VAN. DINING 9' CLG. / LVP FLR.13'-6" x 8'-2" (146 SQ. FT.) 12'x10' SCREEN PORCH TREX DECKING PER SPECS MANUF. TRUSSES24 O.C.40'-0" 14'-6"12'-0" 7'-6"10'-10"5'-6"8'-3"68'-0"6'-0"52'-0"11'-2"3'-8"5'-4"9'-5 3/4"7"8'-6"5'-2 1/2"4'-1 3/4"5'-8 1/4"3'-9 1/2"68'-0"4'-0"29'-0"25'-0"6'-9 1/2"13'-4"3'-2"8'-6 1/2"12'-0"5'-0"2'-0"18'-0"19'-0"21'-0" 13'-0"6'-0" 6'-2 1/2"6'-9 1/2" 11'-3"9'-9" RADON VENT SD SMOKECM / 2'-2 3/4"1'-6 1/2"2424 PICT. @ 8'2424 PICT. @ 8'1'-11"1'-11" 3068 BARN DR.2424 FX @ 8'5'-0"WD. STEP 2'-0"2'-4"4'-0"5'-0"12" CANT. 3'-0"3'-0"2-2x102-2x102-2x102-2x10MANUF. TRUSSES24 O.C.FP CHASEFALSE 2-9 1/2" LSL 2-2x10 (2) TR (2) TR 2-2x10 2-9 1/2" LSL P.H. TR 3'-6"7'-0"3'-4"3'-0"16'-2" 7'-11" 23'-10"10'-0"2 1 0 6 8 TR 2x6 1/2 WALL R&SH 2668 PANTRY 9' CLG. / LVP (5) SH. 9' CLG. / LVP 2/10 x 6/7 SRO10'-8 3/4"7"6'-8 1/4"5'-11 1/4"7'-9"4'-9 1/4" 1'-0" 11"2x65'-11 1/4" 3'-9" 8'-4"8'-10 1/2"2'-3"10'-0"3 - 3672 SH @ 8' 3-11 7/8" LSL 2 1 0 6 83'-11"2'-0"(3) 2424 FX @ 8'2-2x102x6 2x6 2x6 1'-9 1/2" w/ WD. CAP2x6 1/2 WALL 2 - 2068 BENCH / HOOKS8/0 H. SOFFIT SOFFIT2x6RADON VENT 5'-2 1/4" 2'-7 1/2"8/0 H. 14'-8" 5 1/2" 3'-11"2'-1 3/4"3'-0"7'-1 1/2"6'-0 3/4" EQ.EQ. 2'-0 3/4"7'-1 1/2"6'-0 3/4"5'-11"1'-6"14'-8 1/2"2'-7 1/2"4'-2 3/4"9'-0 1/4"4'-4 1/2"4'-3 1/2"2'-5"9'-8"2'-0" 6'-0 3/4"5'-11 1/4"7"4'-4"7 1/4"5'-11 1/4"5'-1"8' SOFFIT7'-0"7"2x6 7" 12'-0" STONE WHERE INDICATED (3) TRR&SH2468PORCH CONCRETE MANUF. TRUSSES 24 O.C. 18" LP COL. * BEADBD. CLG. 8'-6" 5'-8"2-7 1/4" LSL (DR)LP SOFFIT 3"1'-2" 2-7 1/4" LSL (DR) 3"1'-2"3"1'-2"3"1'-2"2-7 1/4" LSL (DR) PER SPECSRAILING 48" H.BUILT-INS48" H.BUILT-INS BUILT-IN BASE / UPPERRESOURCE CENTER STAINED CLG. (1 COAT)FIBRGLS.60x34 SHWR.UNIT2'-0 1/2" INSULATE WALL SOUND BI-PASS SHWR. DR.BI-PASS SHWR. DR.2'-0" TYP. FLR. TO CLG.STONE FACE 2'-10" (VERIFY LOCATION)FLOOR VENT2'-7"2'-7"2-2x102-2x10CUSTOM DESIGN (2) WIRE SH. @ 42" & 84" NOTE: 2-9 1/2" LSL (FULL LENGTH)2-9 1/2" LSL (FULL LENGTH)2-9 1/2" LSL (FULL LENGTH)-Min. 15" clearance to any obstruction from center of W.C., 24" in front(typ). CS-PF CS-PF 5 7 07-00-BUYERPROJECT # BUYER S/O BUYER S/O REVISIONS: STARTED: AGENT:X X"HAMPTON" 1660 VILLA HOMEMARK ELLIOTT HOMES4-10-21 SELECTLOT 10, BLOCK 6, SUMMERS CREEK17971 GRESFORD LN., LAKEVILLE, MN6-3-21 PERMIT 7-28-21 REV. PERMIT OF SHEET SCALE: 1/4" = 1'-0" SECTION1 5 N.T.S. HOUSE / DECK CONNECTION DETAIL4 5 3/4" T & G FLOOR NOTE: SUBFLOOR JOINTS SHALL BESTAGGERED FROM FLOOR TRUSS ORJOIST JOINTS R=0.61 R=49.00 R=50.25 R=0.58 R=.061 TOTAL TRUSSES - 24" OC BLOWN INSULATION INTERIOR AIR FILM VAPOR BARRIER 15/32" OSB SHTG. 15# FELT EXTERIOR AIR FILM ICE AND SNOW SHIELD 30 YR. ARCH. ASPHALT SHINGLES 5/8" GYP BD ALUM. SOFFIT & FASCIA 1/2" GYP BD INTERIOR AIR FILM TOTAL SIDING PER SPECS 2x6 STUDS 16" OC R=1.06 R= R= R=21.00 R=0.45 R=0.17 R=23.36 VAPOR BARRIER FULL WALL BATT INSUL. EXTERIOR AIR FILM R=0.68 7/16" OSB SHTG. 8" AGGREGATE6 MIL POLY. LAP SEAMS 12"1'-4"HEEL HT.1/2" GYP. SHEATHING ON GARAGE WALLS 5/8" TYPE 'X' GYP. BD. ON GARAGE CEILS. 18" FLOOR TRUSSES9'-1 1/8"T.O. SUBFLR. T.O. PLATE TRUSSES @ 24" O.C. (DESIGNED BY MFR) 6 12 R-49 INSUL.9'-4"GARAGE 4" SLOPED CONC. W/ REBAR PERENGINEERS REPORT POURED WALL DRAIN TILE 10" POURED WALL R-5 INSUL. ATINTERIOR FOUND.9'-1 1/8"O. BATH OWNERS BDRM. 20x8 CONC. FTG.16x8 CONC. FTG. 16x8 CONC. FTG. NOTE: TOP HUNG TRUSSES AT FRONT OF HOME (9'-4" H. FDN. WALL) SPRAY FOAM RIM SPRAY FOAM RIM 8'-2" +/-FOUND. HELD IN 2" FOR INSULATION TYP. NOTE: (INSUL. FLUSH w/ SHTG.) CANT. 2x8 SILL PLT. 1-1/2"3 1/2" CONC. FLOOR 2" RIGID INSULATION R-10 w/ WATCHDOG WATERPROOF COATING AROUND HOUSE FOUND.8 1/4"6"HEEL HT.6 12 4 1/4"HEEL HT.FUT. BDRM. #5 R.I. BATH 8 1/4"4" 3'-6"8'-6"4 12 2'-0"8"1'-6 3/4"20x8 CONC. FTG. T.O. LOOKOUT R-5 THERMAX AT INTERIOR FOUND. AS REQUIRED 6 12 JOIST W/ 2-3/8" LAG BOLTS ICE & WATER EXTENDS 5" UP SHEATING UNDER INSTALL TOP OF LEDGER3 5/8" BELOW TOP OF 3/4" SUBFLOOR (THIS ALLOWS 5/4 X 4 THRESHOLDAT DOOR) HANGER TREATED 2X10 LEDGER RUN HOUSE WRAP BEHIND LEDGER (LEAVE 6" TAIL @ TOP, BOTTOM, & SIDES) HOUSEWRAP @ 24" O.C. -OR- EMBED 2" MIN.8 INCHES O.C. MAX OR EQUAL, W/ "LEDERLOK" FASTENERS CONT. 2X4 RIBBON SPRAY FOAM INSUL. R-21 MIN. RIM BOARD TREATED JOIST JOIST RIM BD. SKIRT 1" HOUSE END OF DECK HOUSE LATERAL LOAD SIMPSON DTT1Z DECK-TO CONNECTOR - (4) PER DECK OR 8-10DX1 1/2" NAILS 6-SD#9X1 1/2" SCREWS HDG WASHER OR SDWH 3/8" HDG LAG SCREW WITH TIMBER-HEX HDG SCREW (SHOWN) INTO TOP PLATE, STUDS, OR HEADER CONT. 2X8 RIBBON DRAIN TILE 3/4" WASHED ROCK CONTINUOUS UNDER SLAB0'-16" SILT FABRIC FOUNDATION WALL CONC. FTG. 4" DRAIN TILE 2 SCALE: NO SCALE5 TOP OF FDN.RIM DETAIL3 SCALE: NO SCALE5 2" RIGID INSULATION R-10 w/ WATCHDOG WATERPROOF COATING AROUND HOUSE FOUND. 2" RIGID INSULATION R-10 w/ WATCHDOG WATERPROOF COATING AROUND HOUSE FOUND. 2x8 TRTD. SILL SHEATHING FLUSH WITH INSULATION NOTE: FOUNDATION TO BE HELD IN 2" FROM SHEATHING & OUTSIDE DIMENSIONS. CANTED 1-1/2" 6 7 07-00-BUYERPROJECT # BUYER S/O BUYER S/O REVISIONS: STARTED: AGENT:X X"HAMPTON" 1660 VILLA HOMEMARK ELLIOTT HOMES4-10-21 SELECTLOT 10, BLOCK 6, SUMMERS CREEK17971 GRESFORD LN., LAKEVILLE, MN6-3-21 PERMIT 7-28-21 REV. PERMIT OF SHEET SCALE: 1/4" = 1'-0" SECTION1 6 N.T.S. PORTAL FRAME DETAIL2 6 N.T.S. RADON DETAIL3 6 SIMPSON STRONG TIE Ab46z 4" LEDGE HEADER HURRICANE CLIP ATTACHEDTO COLUMN & BEAM 11 7/8" OSB STRINGER W/ 2X4 BRACING 10 1/2" BULLNOSE LSL TREAD1X8 PINE S4S RISER NOTE: MAX RISE= 7 3/4" MIN. RUN= 10" 6'-8" CLEAR HEADROOM BATH BEDROOM #2 / OFFICEGREAT RM. 3/4" T & G FLOOR NOTE: SUBFLOOR JOINTS SHALL BESTAGGERED FROM FLOOR TRUSS ORJOIST JOINTS ALUM. SOFFIT & FASCIA 8" AGGREGATE6 MIL POLY. LAP SEAMS 12" 18" FLOOR TRUSSES1'-6 3/4"9'-1 1/8"T.O. SUBFLR. T.O. PLATE TRUSSES @ 24" O.C. (DESIGNED BY MFR) R-49 INSUL.9'-4"W/ REBAR PER ENGINEERS REPORT POURED WALL DRAIN TILE 10" POURED WALL R-5 INSUL. ATINTERIOR FOUND. 20x8 CONC. FTG.16x8 CONC. FTG. NOTE: TOP HUNG TRUSSES AT FRONT OF HOME (9'-4" H. FDN. WALL) SPRAY FOAM RIM SPRAY FOAM RIM 8'-2" +/-FOUND. HELD IN 2" FOR INSULATION TYP. NOTE: (INSUL. FLUSH w/ SHTG.) CANT. 2x8 SILL PLT. 1-1/2" 3 1/2" CONC. FLOOR CONC. STOOP 2" RIGID INSULATION R-10 w/ WATCHDOG WATERPROOF COATING AROUND HOUSE FOUND. PORCH 14" SQ. LP COLUMN 20x8 CONC. FTG.1'-4"HEEL HT.6 12 T.O. LOOKOUT MECH. / STORAGEFUT. FAMILY ROOM 8 12 3'-6"KITCHEN 8 1/4"4x4 TRTD. COL. 2x OVER 10" TRIM 2 5 3 5 R-5 THERMAX AT INTERIOR FOUND. AS REQUIRED DINING 8 12 1'-3"SIMPSON STHD14 HOLD DOWN SIMPSON LSTA36 STRAP ON INSIDE FACE OF WALL 5/8" ANCHOR BOLT 1/2" OSB SHEATHING HEADER- SEE PLAN FOR SIZE FASTEN SHEATHING TO HEADER WITH 8d COMMON OR GALVANIZED BOX NAILS IN 3" GRID PATTERN ASSHOWN, AND 3" O.C. IN ALL FRAMING MEMBERS TYP. SHEATHING SPLICE (IF NEEDED) MUST BE LOCATED WITH-IN 24" OF THE MID HEIGHT OF THE DOOR OPENING. PROVIDE 2-2X6BLOCKING BEHIND SPLICE FASTEN TOP PLATE TO HEADER WITH2 ROWS OF 16d SINKER NAILS 3" O.C. BLOCK BACK SIDE OF HEADER FLUSH WITH STUDSAT STRAP LOCATIONS UNEXCAVATED SOIL ALL SLABS WILL HAVE A MIN. 4" CLEAN AGGREGATE, COVERED BY 6 MIL POLY. THIS POLY WILL HAVE 12" LAP AT ALL SEAMS. ALL TEARS OR PUNCTURES WILL BE SEALED OR COVERED BY POLY. ALL OPENINGS WILL BE SEALED USING POLYURETHANE CAULK OR ELASTOMERIC SEALANT AT ALL OPNGS. AN INSTALLED 3" GASTIGHT PVC PIPE WILL BE CONNECTED TO THE DRAIN TILE SYSTEM. A "T" FITTING WILL BE INSTALLED WITH 10 L.F. EACH END OF THE "T", OF PERFORATED PIPE, INTO THE DRAIN TILE SYSTEM. THE SHORTEST ROUTE WILL BE USED TO EXIT THE ROOF SYSTEM, WITH A MAX. OF 2 90 DEGREE ELBOWS. IN UNCONDITIONED AREAS, THE RADON EXHAUST PIPE WILL BE INSULATED WITH AN R4 SLEEVE. THIS PIPE WILL BE LABELED "PASSIVE RADON" AT ALL ACCESSIBLE LOCATIONS. AT ROOF EXIT LOCATIONS, MAINTAIN A 10' DISTANCE TO ANY WINDOW LOCATION, 2' BELOW EXHAUST POINT AND ANY ADJACENT STRUCTURE. THE LOCATION OF THE EXIT POINT, IN TRUSS AREA, WILL BE CLEAR OF ANY OBSTRUCTIONS WITHIN 24" HORIZONTALLY AND 36" VERTICALLY. INSTALL AN OUTLET AND PULL CHORD LIGHT FOR FUTURE EXHAUST FAN ADDITION. SCALE: 3/16" = 1'-0" MAIN FLR. ELECTRICAL PLAN 7 7 07-00-BUYERPROJECT # BUYER S/O BUYER S/O REVISIONS: STARTED: AGENT:X X"HAMPTON" 1660 VILLA HOMEMARK ELLIOTT HOMES4-10-21 SELECTLOT 10, BLOCK 6, SUMMERS CREEK17971 GRESFORD LN., LAKEVILLE, MN6-3-21 PERMIT 7-28-21 REV. PERMIT OF SHEET SCALE: 3/16" = 1'-0" LOWER LEVEL ELECTRICAL PLAN TVABV. FP.NOTE: TECH TUBE TVW.P.CLG. FAN G.F.I.P.S3S3INSTALLED LTS.PENDANTS C/L 8'-0"3'-2"4'-7 1/2"TV SD GDO G.F.I.P.SG.F.I.P.G.F.I.P.W.P.SS S 3S SDISP SS TO LIGHT S G.F.I.P.DW SMOKECM / SMOKECM / SS4S SS S S G.F.I.P.S3 S3 S GAS RANGEMICRO ABV. LNDRY. DRYERWASHER (VENT TO OUTSIDE) REF. KITCHEN GREAT ROOM FOYER O. BATH GARAGE O. CLST BEDROOM #2 / OFFICE OWNERS BDRM. SD MUDRM. DINING 12'x10' SCREEN PORCH PANTRY SG.F.I.P.S3S3S3SSS3 S3 S3BATH PORCH QUAD QUAD NOTE: WALL MNT. HT.NOTE: WALL MNT. HT. S FAN / LIGHT INSTALLED SSFAN / LIGHTINSTALLED S FAN / LIGHT INSTALLED S DUPLEX CONVENIENCE OUTLET DUPLEX OUTLET ABOVE COUNTER WEATHERPROOF DUPLEX OUTLET HALF-SWITCHED DUPLEX OUTLET DUPLEX OUTLET IN FLOOR 220 VOLT OUTLET WALL SWITCH THREE-WAY SWITCH FOUR-WAY SWITCH CEILING MOUNTED INCANDESCENT LIGHT FIXTURE WALL MOUNTED INCANDESCENT LIGHT FIXTURE RECESSED INCANDESCENT LIGHT FIXTURE LIGHT FIXTURE WITH PULL CHAIN TRACK LIGHT FLOURESCENT LIGHT FIXTURE EXHAUST FAN EXHAUST FAN/LIGHT COMBINATION CHIMES (OPTIONAL) SMOKE DETECTOR TELEPHONE (OPTIONAL) TELEVISION (OPTIONAL) THERMOSTAT ELECTRIC METER ELECTRIC PANEL SPEAKER (OPTIONAL) TV T M CH SD P.C. S S S 4 3 W.P. ELECTRICAL KEY DUPLEX OUTLET (GROUND FAULT PROTECTED)G.F.I.P. RECESSED INCANDESCENT EYE BALL FIXTURE CARBON MONOXIDE DETECTORCM GARAGE DOOR OPENER OUTLETGDO FLUORESCENT LIGHT PER SPEC FAN/LIGHT COMBO PREWIRE, PROVIDE ADEQUATE SUPPORT 4 BULB FIXTURE 3 BULB FIXTURE 200 AMP SERVICE LIGHTING PACKAGE: T.B.D. LINE TO DRYER: T.B.D.G.F.I.P.EXCH.AIR SMOKECM / S S3S TO LIGHT G.F.I.P.FURN F.D. WH MECH. / STORAGE WS BDRM. #3 FAMILY ROOM L.L. BATH SUMP UNEXCAVATED FILL FOR SLAB A/C UNIT w/ BRACKET S S SSSG.F.I.P.S3 S SMOKECM / SD H20 * HUMIDIFIER NOTE: FREEZER OUTLET (VERIFY LOCATION) TV 3 S S BW 07-00-BUYERPROJECT # BUYER S/O BUYER S/O REVISIONS: STARTED: AGENT:X X"HAMPTON" 1660 VILLA HOMEMARK ELLIOTT HOMES4-10-21 SELECTLOT 10, BLOCK 6, SUMMERS CREEK17971 GRESFORD LN., LAKEVILLE, MN6-3-21 PERMIT 7-28-21 REV. PERMIT N.T.S. MAIN LEVEL BRACEWALL2 BW N.T.S. BRACEWALL DETAILS3 BW N.T.S. LOWER LEVEL BRACEWALL1 BW GARAGE PORTAL FRAMING PER BUILDING CODE IRC R602.10.6.4 BRACED WALL METHOD CS-WSP 2'-11" PANEL 4'-0" PANELBRACED WALLLINE 1BRACED WALLLINE A BRACED WALL LINE C BRACED WALLLINE 24'-0" PANEL4'-0" PANEL4'-0" PANEL4'-0" PANEL5'-0" PANEL 4'-11" PANEL3'-5" PANEL 6'-7" PANEL3'-1" PANEL BRACED WALL LINE B 10'-0" GYP. PANEL 5'-6" GYP. PANEL LNDRY.KITCHEN GREAT ROOM FOYER O. BATH GARAGE O. CLST BEDROOM #2 / OFFICE OWNERS BDRM. MUDRM. DINING PANTRY 4'-0" PANEL4'-0" PANEL4'-0" PANEL4'-4" GYP. PANELBATH PORCH 12'x10' SCREEN PORCH MIN. 3''x11 1/4'' NET HEADER(STEEL HDR. PROHIBITED) EXTENT OF HEADER W/ SINGLE PORTAL FRAME ONE BRACED WALL PANEL 10'-0'' MAX. HEIGHT(TOP OF HDR.)TOP OF FDN. TOP OF CONC FLOOR AT OPENING MIN. 2-2x4 FRAMING STUD POST CONTINUOUS HEADER WITH DOUBLE PORTAL FRAMES TWO BRACED WALL PANELS 6' TO 18' OPENING FASTEN TOP PLATE TO HEADER W/ 2 ROWS OF 16d SINKER NAILS @ 3'' O.C. TYP. 1000 LB. STRAP OPPOSITE SIDE OF SHEATHING FASTEN SHEATHING TO HEADER W/ 8d COMMON OR GALV. BOX NAILS IN 3'' GRID PATTERN SHOWN AND 3'' O.C. IN ALLFRAMING(STUDS, BLOCK'G AND SILLS)TYP. MIN. WIDTH PER TABLE R602.10.5 3/8'' MIN. WOOD STRUCTURAL PANEL SHEATH'G. MIN. 2-2x4 MIN. 4200 LB. TIE DOWN DEVICE(EMBED INTO FOUNDATION AND NAILED INTO FRAMING MIN. (2) 1/2'' DIA. ANCHOR BOLT INSTALLED PER R403.1.6 W SEE LEFT FOR TYP. PORTALFRAME CONST. FOR A PANEL SPLICE(IF NEEDED) PANELEDGES SHALL BE BLOCKED AND OCCURWITHIN 24'' OF MID-HEIGHT. ONE ROW OF TYP. SHEATH'G. TOFRAMING NAILING IS REQUIRED.IF 2x4 BLOCK'G. IS USEDTHE 2x4'S MUST BE NAILED TOGETHER W/ 3 16d SINKER NAILS W/ 2''x2''x3/16'' PLATE WASHER12'-0'' MAX. HEIGHT(TOP OF WALL)FULL HEIGHT OF WALL - SEE TO RIGHT FOR SPLICESPONY WALL HT.EXTENT OF HEADER TENSION STRAP PERTABLE R602.10.6.4 (ONOPPOSITE SIDE OF SHEATHING ANCHOR BOLTSPER SECTION R403.1.6 BRACED WALL LINECONTINUOUSLYSHEATHED WITH WOOD STRUCTURALPANELS TOP OF FLOOR AT OPENING FLOOR FRAMING ASSEMBLY PER PLAN W/ WOOD STRUCTURAL PANEL SHEATHING TOP OF FLOOR AT OPENING FLOOR FRAMING ASSEMBLY PER PLAN WOOD STRUCTURAL PANEL SHEATHING TO TOP OF BAND OR RIM JOIST NAIL SOLE PLATE TO FLR FRAMING PERTABLE R602.3(1) (2) FRAMING ANCHORS APPLIED ACROSSSHEATHING JOINT WITH A CAPACITY OF 670# IN HORIZ. AND VERT. DIRECTIONS SEE LEFT FOR TYP. PORTALFRAME CONST. ON CONCRETE FOUNDATION ON RAISED WOOD FLOOR - FRAMING ANCHOR OPTION TOP OF FLOOR AT OPENING FLOOR FRAMING ASSEMBLY PER PLAN W/ WOOD STRUCTURAL PANEL SHEATHING TOP OF FLOOR AT OPENING FLOOR FRAMING ASSEMBLY PER PLAN WOOD STRUCTURAL PANEL SHEATHING TO TOP OF BAND OR RIM JOIST NAIL SOLE PLATE TO FLR FRAMING PERTABLE R602.3(1) SEE LEFT FORTYP. PORTALFRAME CONST. ON RAISED WOOD FLOOR - OVERLAP FLOOR OPTION MIN. OVERLAP 9 1/4''WOOD STRUCTURAL PANEL SHEATHING CONTINUOUS OVER BAND OR RIM JOIST MIN. OVERLAP 9 1/4''ATTACH TO RIM/BAND JOIST W/ 8d COMMON NAILS AT 3'' O.C. AS SHOWN DBL TOP PLATE BOTTOM PLATE STUDS AT 16'' O.C. W/ 6d NAILS @ 6'' O.C. 4'-0"8'-0'' MIN., SEE PLANINTERMEDIATE 6''3"W/ 6d NAILS @ 3'' O.C. EDGES NAILED BDRM. #3 FAMILY ROOM 3'-9" PANEL4'-0" PANEL2'-8" PANEL 4'-0" PANEL NEW RESIDENTIAL CONSTRUCTION SWPPP VERIFICATION This form must be completed and submitted with all new residential permit applications. A National Pollutant Discharge Elimination System (NPDES) Construction Stormwater Permit is required for “Construction activity that results in land disturbance of equal to or greater than one (1) acre or if a project is part of a common plan of development that will ultimately disturb greater than one (1) acre,” (NPDES Permit, Section 1.2). Project Site Address: _____________________________________________________________________ Company Name: _________________________________________________________________________ *Primary Company Contact: _________________________________________________________________ *Should a site be deemed noncompliant, this individual will be notified Phone #: ____________________________ Email: ______________________________________________ If you are not covered under a NPDES Construction Stormwater Permit administered by the Minnesota Pollution Control Agency (MPCA), an erosion and sediment control plan MUST be approved as part of the residential building permit application. “Permittees must ensure a trained person will inspect the entire construction site at least once every seven (7) days during active construction and within 24 hours after a rainfall event greater than ½ inch in 24 hours,” (NPDES Permit, Section 11.2). The City of Lakeville reserves the right to request weekly inspection logs. The City of Lakeville may issue a STOP WORK ORDER; withhold building inspections; or, draw on securities/escrows to bring the site into compliance with the NPDES Construction Stormwater Permit (MN R 100001) or erosion and sediment control plan. Contact information of person CERTIFIED to provide weekly onsite erosion and sediment control inspections and corrective actions: Name: ____________________________________ Company: ___________________________________ Phone # (24 hr Contact): ______________________ Email: ______________________________________ Entity that Provided Training: __________________________ Certification Expiration Date: ____________ NOTE: Prior to any land-disturbing activity, all erosion and sediment controls must be installed I understand the above information to be accurate and I have read, understood, and accepted all terms and conditions of the NPDES Permit (MN R 100001). Signature: ________________________________________________ Date:_________________________ Contact the City of Lakeville with questions at erosion@lakevillemn.gov or 952-985-4500 Nick Reimler KP X07/27/21