HomeMy WebLinkAboutLA191805 17870 Eclipse Ave Permit PackRESIDENTIAL BUILDING
PERMIT APPLICATION
CITY OF LAKEVILLE
BUILDING INSPECTIONS DEPARTMENT
20195 HOLYOKE AVENUE
LAKEVILLE, MN 55044
952-985-4440
Office Use Only
__________________
Permit Number
___________________
Received By
___________________
Date Received
___________________
Fee Total
SITE ADDRESS:
MAILING ADDRESS: CITY: STATE: ZIP:
JOB DESCRIPTION:__________________________________ MASTER PLAN: (Number or Address)____________________
LIST OTHER STRUCTURES ON PROPERTY:_______________________________________________________________
ESTIMATED VALUATION: PROPOSED START DATE: END DATE:
(New Residential Only): LEGAL DESCRIPTION: LOT: _____ BLOCK: _____ SUBDIVISION:
APPLICANT IS: RESIDENT OWNER CONTRACTOR EMAIL
NEW MODEL HOME: YES NO (IF YES – ADMINISTRATIVE PERMIT REQUIRED)
PLEASE FILL OUT THE FOLLOWING COMPLETELY (All Contractor information must be as listed on State License)
RESIDENT OWNER
NAME:_______________________________________________________________________________
HOME PHONE #:_____________________________ CELL PHONE:___________________________
GENERAL CONTRACTOR
Homeowner
Contractor
CONTRACTOR:_______________________________________________________________________
LICENSE #:BC______________ LEAD CERTIFICATE#_______________ (PRE 1978 STRUCTURE)
OFFICE PHONE #:_____________________________ CELL PHONE:___________________________
ADDRESS:____________________________ CITY:________________ ST:______ ZIP:____________
PLUMBING WORK
Homeowner
Contractor
CONTRACTOR:__________________________________________LICENSE #: PM______________
OFFICE PHONE #:_____________________________ CELL PHONE:___________________________
ADDRESS:____________________________ CITY:________________ ST:______ ZIP:____________
MECHANICAL WORK
Homeowner
Contractor
CONTRACTOR:________________________________________ _______________________________
OFFICE PHONE #:_____________________________ CELL PHONE:___________________________
ADDRESS:____________________________ CITY:________________ ST:______ ZIP:____________
BOND #:_______________________________________ EXPIRATION DATE____________________
SEWER/WATER CONTRACTOR
New Construction Only
NAME:________________________________________________ ______________________________
HOME PHONE _____________________________ CELL PHONE:______________________________
BOND #:_______________________________________ EXPIRATION DATE____________________
INTEREST EARNINGS ON THE ESCROW ACCOUNTS, IF ANY, ARE RETAINED BY THE CITY TO OFFSET THE
ADMINISTRATIVE COSTS ASSOCIATED WITH PROCESSING THE ESCROW APPLICATION AND REFUND. I HEREBY
APPLY FOR A BUILDING PERMIT AND I ACKNOWLEDGE THAT THE INFORMATION ABOVE IS COMPLETE AND
ACCURATE; THAT THE WORK WILL BE IN CONFORMANCE WITH THE ORDINANCES AND CODES OF THE CITY AND
WITH THE STATE BUILDING CODE, THAT I UNDERSTAND THIS IS NOT A PERMIT AND WORK IS NOT TO START
WITHOUT A PERMIT AND THAT THE WORK WILL BE IN ACCORDANCE WITH THE APPROVED PLAN.
NAME OF APPLICANT (Please Print)DATE
APPLICANT’S SIGNATURE:
www.lakevillemn.gov
5/6/21
DM
RESIDENTIAL BUILDING PERMIT APPLICATION
PAGE 2
OFFICE USE ONLY
BUILDING PERMIT TYPE REQUIRED INSPECTIONS
SINGLE FAMILY DWELLING BUILDING
DUPLEX AS BUILT
TOWNHOUSE UNITS BUILDING FINAL
DETACHED TOWN HOUSE UNIT DECK FOOTING
CONDO FIREPLACE
ACESSORY BUILDING FOOTING
REROOF FOUNDATION
RESIDE FRAMING
PORCH FRAMING
GARAGES
INSULATION
RES ADDN/REPAIR/RMDL
DECK
PORCH
GARAGES LATH
LOWER LEVEL FINISH LOWER LEVEL FINAL
ADDITION OTHER
FOUNDATION ONLY PORCH FOOTING
MISCELLANEOUS POURED WALL
DEMO SEPTIC TANK REMOVAL
MOVED SITE
MECHANICAL
CITY BUILDING VALUATION: $AIR TEST
FINAL
BUILDING PERMIT FEES ROUGH-IN
$PERMIT FEE PLUMBING
$PLAN CHECK FINAL
$SURCHARGE ROUGH-IN
$METRO SAC METER SIZE
$CITY WATER HOOKUP UNIT PRESSURE REDUCING VALVE
$CITY SEWER HOOKUP UNIT SEWER/WATER
$LANDSCAPE ESCROW SEWER/WATER
$TREE ESCROW FINAL
$MISC ESCROW STREET DRAINTILE
$PLUMBING BUILDING INFORMATION
$MECHANICAL TYPE OF CONSTRUCTION
$SEWER WATER ZONING
$OTHER CODE EDITION
$TOTAL FIRE SUPPRESSION SYSTEM
OCCUPANCY GROUP
APPROVED BY:
BUILDING INSPECTOR: Date:
PLUMBING/MECHANICAL
INSPECTOR: Date:
COMMENTS:
20195 Holyoke Avenue, Lakeville, MN 55044
952-985-4400 952-985-4499 fax
www.lakevillemn.gov
Sewer & Water Tie Card
Address:________________________________________
Contractor:______________________________________
Permit Number:__________________________________
Final Date:________________
Street Drain-Tile:______
Size of Water Service: 1”
Comments: AIRTEST SANITARY OVER 20’/2 FITTINGS
THIS CARD MUST BE COMPLETED AND ON-SITE AT TIME
OF SEWER & WATER INSPECTION
MAIN FLOOR1' -8 1/4"UPPER PLATE20' -7 1/4"T.O. FOUNDATION0' -0"T.O. FOUNDATION0' -0"MAIN PLATE10' -9 3/8"MAIN PLATE10' -9 3/8"UPPER FLOOR12' -6 1/8"MAIN FLOOR PLATE HEIGHT9' - 1 1/8"UPPER FLOOR PLATE HEIGHT8' - 1 1/8"GARAGE PLATE HEIGHT10' - 9 3/8"(2) 8x8x36" CORBELVINYL BOARD & BATTEN TYP.6" SMARTSIDE FRIEZE BOARDTYP. @ FRONTVINYL LAPSIDING TYP.CULTURED STONEW/ CONCRETE CAP6" SMARTSIDE TRIM @ FRONTTYP.SEE COLUMN DETAILSHEET A-5013' - 6"8" 12"8" 12"7" / 12"6" SMARTSIDE STORY BOARD6" BUMPED OUTLOUVER W/ CORBELSVINYL SHAKES TYP.ADDRESS STONEALUMINUM SOFFIT & FASCIA TYP.8" 12"STAINED WOODCOLUMNS7" / 12"24" RETURNS TYP.8" / 12"8" / 12"8" / 12"7" / 12"7" 12"24" RETURNS TYP.8" / 12"8" / 12"8" / 12"8" / 12"ALUMINUM SOFFIT& FASCIA TYP.VINYL SIDING &CORNERS @ SIDES & REAR8" 12"8" 12"7" / 12"THE IDEAS, DESIGNS, DRAWINGS AND SPECIFICATIONS REPRESENTED HEREIN ARE AND SHALL REMAIN THE EXCLUSIVE COPYRIGHT PROPERTY OF ONETENTEN HOMES. NO PART THERE OF SHALL BE USED, COPIED, OR DISCLOSED IN CONNECTION WITH ANY WORK OR PROJECT OTHER THAN THE SPECIFIED PROJECT FOR WHICH THEY HAVE BEEN PREPARED WITHOUT THE WRITTEN CONSENT OF ONETENTEN HOMES.THE PLANS FURNISHED HEREIN WERE PREPARED UPON REQUEST BY DRAFTSPERSONS WHO ARE NOT REGISTERED ARCHITECTS OR ENGINEERS. ONETENTEN HOMES ASSUMES NO RESPONSIBILITY FOR STRUCTURAL OR DIMENSIONAL ERRORS OR OMISSIONS.THE CONTRACTOR AND/OR OWNER MUST VERIFY AND CHECK ALL NOTES DETAILS, ELEVATIONS, SECTIONS AND FLOOR PLANS AND NOTIFY ONETENTEN HOMES OF ANY ERRORS OR OMISSIONS PRIOR TO THE START OF CONSTRUCTION. NO WARRANTIES ARE EXPRESSED OR IMPLIED INCLUDING COMPLIANCE OF THIS PLAN WITH APPLICABLE BUILDING CODE REQUIREMENTS. THE SELECTION AND APPLICATION OF CORRECT STRUCTURAL MATERIALS IS THE RESPONSIBILITY OF THE BUILDER, THE OWNER OR THE USER OF THESE PLANS.P.O. BOX 3915411 LAKERS LANE, SUITE 204NISSWA, MN 56468PH (612) 327-7582NORTHHOUSE-RD.COMDATEFINISHED SQUARE FEETPROJECTSHEETUPPER:MAIN:LOWER:RELEASEDREV. 1REV. 2REV. 3REV. 4REV. 5PLATE HEIGHTSUPPER:MAIN:POUR:UNSPECIFIED HEADERS TO BE 2-2x10 W/ 2 TRIMMERS10" MIN. STAIR TREAD DEPTH & 7 3/4" MAX STAIR RISER HEIGHTALL ANGLES ARE 45 DEGREES UNLESS NOTED OTHERWISEALL EXTERIOR DIMENSIONS ARE TO OUTSIDE OF SHEATHING, CONCRETE OR FOUNDATION INSULATIONBRAINERD LAKESTWIN CITIES3000 COUNTY ROAD 42 WEST, SUITE 202 BURNSVILLE, MN 55337PH (952)-953-4000ONETENTENHOMES.COMTOTAL:5/3/2021 9:39:37 AMTHE SPELBRINK RESIDENCEL7, B7 -PHEASANT RUN 5TH17870 ECLIPSE AVENUELAKEVILLE, MN 55044A-201OTT2175.3.21 CB1699145310753.30.21 TP8'- 1 /18"9'- 1 /18"8'-4" POUR4227THE CONNOR1/4" = 1'-0"A-2011FRONT ELEVATION1/8" = 1'-0"A-2012LEFT ELEVATION1/8" = 1'-0"A-2013RIGHT ELEVATION1/8" = 1'-0"A-2014REAR ELEVATIONSecure door closed until deck isconstructed with a separate permit.Concept Approval ONLYSubject to Field InspectionInspectorDate2020MN BldgCode06/10/2021dmathews
11' - 10"2' - 0"0' - 2"18' - 10"33' - 2"2' - 8 1/2"16' - 3" M.O.2' - 8 1/2"1' - 7 1/2"8' - 3" M.O.1' - 7 1/2"18' - 0"15' - 0"17' - 0"3'-6"(H) x 8"(W) POUREDCONCRETE FOUND. WALL W/2" x 8" INTERIOR LEDGE ON16" x 8" CONCRETE FTG'S.REBAR PER CODE.8'-4"(H) x 10"(W) POUREDCONCRETE FOUND. WALL W/4" x 8" EXTERIOR LEDGE ON20" x 8" CONCRETE FTG'S.REBAR PER CODE.:LOOKOUT WALL:2x6 STUDS @ 16" O.C. ON3'-6"(H) x 8"(W) POUREDCONCRETE FOUND. WALL ON20" x 8" CONCRETE FTG.REBAR PER CODE8'-4"(H) x 8"(W) POUREDCONCRETE FOUND. WALL ON20" x 8" CONCRETE FTG'S.REBAR PER CODE.2x6 STUDS @ 16" O.C. ONHALF-HIGH 6" BLOCK ON16" x 8" CONCRETE FTG'S.REBAR PER CODE.0' - 4"0' - 4"2" FOAM INSULATIONBETWEEN WALL & SLAB11' - 8"8' - 0"54' - 0"42' - 2"11' - 10"6' - 0"5' - 10"36' - 2"6' - 0"19' - 8"15' - 9 1/4"4' - 2 3/4"4' - 2 3/4"11' - 11 1/4"8'-4"(H) x 8"(W) POUREDCONCRETE FOUND. WALL ON20" x 8" CONCRETE FTG'S.REBAR PER CODE.ALL DIMENSIONS ARETO EXTERIOR OF CONCRETE, NOT INSULATIONANCHOR BOLTS ON EACH SIDEOF BEARING POINTANCHOR BOLTS ON EACH SIDEOF BEARING POINT26' - 6"27' - 6"54' - 0"7' - 9"6' - 1"2' - 0"24' - 6"21' - 6"6' - 0"13' - 10"8'-4"(H) x 8"(W) POUREDCONCRETE FOUND. WALL ON20" x 8" CONCRETE FTG'S.REBAR PER CODE.ANCHOR BOLTS ON EACH SIDEOF BEARING POINT42" x 42" x 12" CONCRETE FTG.W/ (4) #5 REBAR EACH WAY42" x 42" x 12" CONCRETE FTG.W/ (4) #5 REBAR EACH WAY30' - 10 1/2"6' - 7"1' - 2 1/2"6' - 11"4' - 5"52' - 0"2' - 0"50' - 0"9' - 9 1/4"22' - 6 3/4":LOOKOUT WALL:2x6 STUDS @ 16" O.C. ON3'-6"(H) x 8"(W) POUREDCONCRETE FOUND. WALL ON20" x 8" CONCRETE FTG.REBAR PER CODE42" x 42" x 12" CONCRETE FTG.W/ (4) #5 REBAR EACH WAY21' - 8"11' - 6":WALKOUT WALL:2x6 STUDS @ 16" O.C. ON3'-6"(H) x 8"(W) POUREDCONCRETE FOUND. WALLW/ 2" x 4" INT. LEDGE ON20" x 8" CONCRETE FTG'S.REBAR PER CODE.:WALKOUT WALL:2x6 STUDS @ 16" O.C. ON3'-6"(H) x 8"(W) POUREDCONCRETE FOUND. WALLW/ 2" x 4" INT. LEDGE ON20" x 8" CONCRETE FTG'S.REBAR PER CODE.LEAVE A 12" GAPIN FOOTING FOR PLUMBING7'-8"(H) x 8"(W) POUREDCONCRETE FOUND. WALL ON16" x 8" CONCRETE FTG'S.REBAR PER CODE.42" x 42" x 12" CONCRETE FTG.W/ (4) #5 REBAR EACH WAY42" x 42" x 12" CONCRETE FTG.W/ (4) #5 REBAR EACH WAY9' - 9 1/4"8' - 2 3/4"22' - 4"52' - 0"STEP FOOTING & FOUNDATIONMAXIMUM 3:1 DROP IN GRADEALLOWED. STEP FOOTING &FOUNDATION AS REQUIRED.STEP FOOTING & FOUNDATIONMAXIMUM 3:1 DROP IN GRADEALLOWED. STEP FOOTING &FOUNDATION AS REQUIRED.THE IDEAS, DESIGNS, DRAWINGS AND SPECIFICATIONS REPRESENTED HEREIN ARE AND SHALL REMAIN THE EXCLUSIVE COPYRIGHT PROPERTY OF ONETENTEN HOMES. NO PART THERE OF SHALL BE USED, COPIED, OR DISCLOSED IN CONNECTION WITH ANY WORK OR PROJECT OTHER THAN THE SPECIFIED PROJECT FOR WHICH THEY HAVE BEEN PREPARED WITHOUT THE WRITTEN CONSENT OF ONETENTEN HOMES.THE PLANS FURNISHED HEREIN WERE PREPARED UPON REQUEST BY DRAFTSPERSONS WHO ARE NOT REGISTERED ARCHITECTS OR ENGINEERS. ONETENTEN HOMES ASSUMES NO RESPONSIBILITY FOR STRUCTURAL OR DIMENSIONAL ERRORS OR OMISSIONS.THE CONTRACTOR AND/OR OWNER MUST VERIFY AND CHECK ALL NOTES DETAILS, ELEVATIONS, SECTIONS AND FLOOR PLANS AND NOTIFY ONETENTEN HOMES OF ANY ERRORS OR OMISSIONS PRIOR TO THE START OF CONSTRUCTION. NO WARRANTIES ARE EXPRESSED OR IMPLIED INCLUDING COMPLIANCE OF THIS PLAN WITH APPLICABLE BUILDING CODE REQUIREMENTS. THE SELECTION AND APPLICATION OF CORRECT STRUCTURAL MATERIALS IS THE RESPONSIBILITY OF THE BUILDER, THE OWNER OR THE USER OF THESE PLANS.P.O. BOX 3915411 LAKERS LANE, SUITE 204NISSWA, MN 56468PH (612) 327-7582NORTHHOUSE-RD.COMDATEFINISHED SQUARE FEETPROJECTSHEETUPPER:MAIN:LOWER:RELEASEDREV. 1REV. 2REV. 3REV. 4REV. 5PLATE HEIGHTSUPPER:MAIN:POUR:UNSPECIFIED HEADERS TO BE 2-2x10 W/ 2 TRIMMERS10" MIN. STAIR TREAD DEPTH & 7 3/4" MAX STAIR RISER HEIGHTALL ANGLES ARE 45 DEGREES UNLESS NOTED OTHERWISEALL EXTERIOR DIMENSIONS ARE TO OUTSIDE OF SHEATHING, CONCRETE OR FOUNDATION INSULATIONBRAINERD LAKESTWIN CITIES3000 COUNTY ROAD 42 WEST, SUITE 202 BURNSVILLE, MN 55337PH (952)-953-4000ONETENTENHOMES.COMTOTAL:5/3/2021 9:39:38 AMTHE SPELBRINK RESIDENCEL7, B7 -PHEASANT RUN 5TH17870 ECLIPSE AVENUELAKEVILLE, MN 55044A-401OTT2175.3.21 CB1699145310753.30.21 TP8'- 1 /18"9'- 1 /18"8'-4" POUR4227THE CONNOR1/4" = 1'-0"A-4011FOUNDATION PLANUFER Ground-Provide 20' Rebar in footing and stubup near electrical service panel.
UP 16RUNEXCAVATEDFURNACESUMPW. H.F. D.MECHANICAL /STORAGE11' - 10"2' - 0"0' - 2"18' - 10"33' - 2"18" FLOOR TRUSSESPER MFG. SPACING2' - 8 1/2"16' - 3" M.O.2' - 8 1/2"1' - 7 1/2"8' - 3" M.O.1' - 7 1/2"18" FLOOR TRUSSESPER MFG. SPACING12' - 2"4' - 0"4' - 0"16' - 0"UNEXCAVATED18' - 0"15' - 0"17' - 0"26' - 6"27' - 6"6' - 0"21' - 6"24' - 6"2' - 0"72/8 x 6/8R.O. 2' -10" x 6' -11"SET ON 3X SILL2x6 STUDS @ 16" O.C. ONHALF-HIGH 6" BLOCK ON16" x 8" CONCRETE FTG'S.REBAR PER CODE.3-14" FLUSH LVL9' - 0"8' - 0"7' - 6"7' - 6"12' - 6"5' - 6"4-2x624" CANT. ABOVE0' - 4"0' - 4"* ALL DIMENSIONS ARE TO EXTERIOR OF SHEATHING/CONCRETE, NOT INSULATION2" FOAM INSULATIONBETWEEN WALL & SLABCO DET.SMOKEDET.FLOOR GIRDER2-2x102-2x1011' - 8"8' - 0"19' - 8"54' - 0"54' - 0"ANCHOR BOLTS ON EACH SIDEOF BEARING POINT2-2x1013' - 10"AIR EX.52' - 0"52' - 0"48" F.G. SHWR3' VANITY22/4 x 6/8R.O. 2' -6" x 6' -11"BEDROOM #5BATHRECREATIONROOM2x6.9' - 8 1/4"3' - 7 1/2"2' - 6"15' - 3 1/2"18' - 10 3/4"159/0 x 6/8 SLIDERR.O. 9' -0" x 6' -8"16' - 2"20' - 0"6' - 0"5' - 10"36' - 2"6' - 0"11' - 10"42' - 2"6' - 7"3' - 7 1/2"2' - 0"10' - 1 1/2"SMOKEDET.CS-WSP2' - 6" B.W.P.CS-WSP4' - 0" B.W.P.CS-WSP3' - 0" B.W.P.CS-WSP3' - 0" B.W.P.CS-WSP3' - 0" B.W.P.CS-WSP4' - 0" B.W.P.39' - 2"5' - 10"5' - 0"KNEE WALL W/PAINTED SPINDLESCS-WSP METHOD BRACED WALL PANELS-8d NAILS 6" ON EDGES & 12" IN FIELD,STACK BETWEEN LEVELS WHEN POSSIBLE.USE (3) 16d NAILS NEXT TO EACHSTUD TO SECURE WALL DOWN TO DECKAT BRACED WALL PANELS.EXPOSURE CATEGORY BASSUMED BRACED WALL NOTES52/6 x 6/8R.O. 2' -8" x 6' -11"52/6 x 6/8R.O. 2' -8" x 6' -11"135/0 x 6/8R.O. 5' -2" x 6' -11"STORAGER & SH.LINEN11/6 x 6/8R.O. 1' -8" x 6' -11"32' - 4"4-2x62-11 7/8" LSL W/ 3 TRIMMERS 2-9 1/2" LVL3-9 1/2" LSL5x7 PSL2-2x10 FLUSH22' - 4"126048 SLR.O. 5' -0" x 4' -0"H.H. 6' -10"224-48-2460 SLR.O. 8' -0" x 5' -0"H.H. 6' -10"84836 PICR.O. 4' -0" x 3' -0"H.H. 1' -8 1/4"21' - 8"11' - 6"2' - 0"50' - 0"WET BARROUGH INSTEP FOOTING & FOUNDATIONMAXIMUM 3:1 DROP IN GRADEALLOWED. STEP FOOTING &FOUNDATION AS REQUIRED.STEP FOOTING & FOUNDATIONMAXIMUM 3:1 DROP IN GRADEALLOWED. STEP FOOTING &FOUNDATION AS REQUIRED.1/4" = 1'-0"A-4021LOWER FLOORTHE IDEAS, DESIGNS, DRAWINGS AND SPECIFICATIONS REPRESENTED HEREIN ARE AND SHALL REMAIN THE EXCLUSIVE COPYRIGHT PROPERTY OF ONETENTEN HOMES. NO PART THERE OF SHALL BE USED, COPIED, OR DISCLOSED IN CONNECTION WITH ANY WORK OR PROJECT OTHER THAN THE SPECIFIED PROJECT FOR WHICH THEY HAVE BEEN PREPARED WITHOUT THE WRITTEN CONSENT OF ONETENTEN HOMES.THE PLANS FURNISHED HEREIN WERE PREPARED UPON REQUEST BY DRAFTSPERSONS WHO ARE NOT REGISTERED ARCHITECTS OR ENGINEERS. ONETENTEN HOMES ASSUMES NO RESPONSIBILITY FOR STRUCTURAL OR DIMENSIONAL ERRORS OR OMISSIONS.THE CONTRACTOR AND/OR OWNER MUST VERIFY AND CHECK ALL NOTES DETAILS, ELEVATIONS, SECTIONS AND FLOOR PLANS AND NOTIFY ONETENTEN HOMES OF ANY ERRORS OR OMISSIONS PRIOR TO THE START OF CONSTRUCTION. NO WARRANTIES ARE EXPRESSED OR IMPLIED INCLUDING COMPLIANCE OF THIS PLAN WITH APPLICABLE BUILDING CODE REQUIREMENTS. THE SELECTION AND APPLICATION OF CORRECT STRUCTURAL MATERIALS IS THE RESPONSIBILITY OF THE BUILDER, THE OWNER OR THE USER OF THESE PLANS.P.O. BOX 3915411 LAKERS LANE, SUITE 204NISSWA, MN 56468PH (612) 327-7582NORTHHOUSE-RD.COMDATEFINISHED SQUARE FEETPROJECTSHEETUPPER:MAIN:LOWER:RELEASEDREV. 1REV. 2REV. 3REV. 4REV. 5PLATE HEIGHTSUPPER:MAIN:POUR:UNSPECIFIED HEADERS TO BE 2-2x10 W/ 2 TRIMMERS10" MIN. STAIR TREAD DEPTH & 7 3/4" MAX STAIR RISER HEIGHTALL ANGLES ARE 45 DEGREES UNLESS NOTED OTHERWISEALL EXTERIOR DIMENSIONS ARE TO OUTSIDE OF SHEATHING, CONCRETE OR FOUNDATION INSULATIONBRAINERD LAKESTWIN CITIES3000 COUNTY ROAD 42 WEST, SUITE 202 BURNSVILLE, MN 55337PH (952)-953-4000ONETENTENHOMES.COMTOTAL:5/3/2021 9:39:39 AMTHE SPELBRINK RESIDENCEL7, B7 -PHEASANT RUN 5TH17870 ECLIPSE AVENUELAKEVILLE, MN 55044A-402OTT2175.3.21 CB1699145310753.30.21 TP8'- 1 /18"9'- 1 /18"8'-4" POUR4227THE CONNORFAN
DN 3RDN 3RUP 17RDN 16R42' - 0"12' - 0"36" REFKITCHENDINING ROOMGREAT ROOMFOYEROFFICEMUD RM.SINKPORCH6' - 0"36' - 0"6' - 0"6' - 0"124/0 x 6/8R.O. 4' -2" x 6' -11"1' - 0"5' - 0"1' - 2"9' - 2"1' - 2"4" CONCRETE SLAB, SLOPETOWARDS DOORS5/8" TYPE X GYP. BD. ALL COMMONWALLS & CEILINGR-38 MIN. INSULATION IN FLOOR ABOVEGARAGE PLATE HEIGHT TO MATCHMAIN FLOOR UNLESS NOTED OTHERWISE20" FLOOR TRUSSESPER MFG. SPACING20" FLOOR TRUSSESPER MFG. SPACINGTYP.0' - 4 1/2"113/0 x 6/8 W/ 12" D.S. SL'S4' - 0"8' - 0"2' - 0"14' - 0"5' - 9"5' - 9"3' - 7"4' - 3"1616' x 8' O.H. GARAGE DOOR54' - 0"17' - 0"15' - 0"18' - 0"103/0 x 6/8 OPG.GARAGE2' - 0"30' - 8"22/4 x 6/8R.O. 2' -6" x 6' -11"R & SH. @ 65"4' - 0"4' - 6"KNEE WALL W/ PAINTED SPINDLES@ 6' -10" H.H.ABOVE LANDING16' - 0"6' - 8 3/4"10' - 6 1/4"2' - 9"DOUBLE FRAMEDWALL FOR REFG. RECESS 39" x 73" 9' - 0"8' - 0"7' - 6"7' - 6"2' - 3"10' - 9"5' - 0"13' - 7"17' - 1"12' - 0"4' - 0"4' - 0"16' - 0"5' - 0"6' - 8"7' - 8"5' - 0"5' - 10"0' - 10"GIRDER TRUSSGIRDER TRUSSFLOORGIRDER2' - 9"3' - 3"SEE COLUMN DETAILSHEET A-501MFG. ROOF TRUSSES@ 24" O.C.2-2x10 CONT.2-2x103-14" LVL FLUSH2-11 7/8"LSL FLUSH2-2x102-9 1/2" LSL DROPPED 2-2x10 DROPPED2-2x103-2x6STAGGEREDUPPERS7' - 10"PORTAL FRAMEW/ HOLD-DOWNS2' - 9"3' - 3"END PANELOVEN /MICRO9' - 6"4' - 0 3/4"3' - 6"93/0 x 6/8 FULL VIEW52/6 x 6/8R.O. 2' -8" x 6' -11"EQEQCS-WSP6' - 0" B.W.P.2' - 0"9" HEAT DUCT2-2x102-2x10 CONT.3-2x103-2x102-2x1024" CANT. ABOVEATTICACCESSCS-WSP3' - 3" B.W.P.CS-WSP1' - 10 1/2" B.W.P.CS-WSP1' - 10 1/2" B.W.P.CS-WSP4' - 0" B.W.P.CS-WSP5' - 0" B.W.P.CS-WSP2' - 9" B.W.P.CS-WSP2' - 9" B.W.P.CS-WSP5' - 0" B.W.P.CS-WSP3' - 0" B.W.P.CS-WSP5' - 0"CS-WSP4' - 0" B.W.P.CS-WSP4' - 0" B.W.P.WALL ABOVE BEARING ONFLOOR TRUSSES2-2x10 W/2 TRIMMERS EA. SIDE3-2x62-2x102' - 0"4-2x636" GAS COOKTOP W/WOOD HOODABOVE2-2x10 FLUSHFLOOR GIRDER14' - 0"POWDERFLEX ROOM22/4 x 6/8R.O. 2' -6" x 6' -11"PANTRYCLOSETSMOKEDET.36" GAS F.P.6' - 0"5' - 0"5' - 10"HHUS482-2x10 DROPPED5x7 PSL DW4-20" LVL FLUSHR & SH.22/4 x 6/8R.O. 2' -6" x 6' -11"148' x 8' O.H. GARAGE DOORR & SH.R & SH.2' - 10"16' - 0"2' - 10"1' - 9"8' - 0"1' - 9"21' - 8"11' - 6"7' - 4"11' - 6"3-24" LVL 2-2x12RECYCLE6' - 6 1/4"10' - 5 3/4"10' - 0 1/4"3' - 5 3/4"3' - 6"5x5 PSL18' - 6"3' - 6"12" SH.12" SH.CS-WSP2' - 3" B.W.P.CS-WSP4' - 0" B.W.P.CS-WSP2' - 6" B.W.P.CS-WSP8' - 0" B.W.P.CS-WSP4' - 0" B.W.P.CS-WSP4' - 0" B.W.P.5x5 PSL4-2x66' - 9"4' - 0"4' - 4 1/2"1' - 5 1/2"5' - 5"20" FLOOR TRUSSESPER MFG. SPACINGMFG. ROOF TRUSSES@ 24" O.C.CS-WSP METHOD BRACED WALL PANELS-8d NAILS 6" ON EDGES & 12" IN FIELD,STACK BETWEEN LEVELS WHEN POSSIBLE.USE (3) 16d NAILS NEXT TO EACHSTUD TO SECURE WALL DOWN TO DECKAT BRACED WALL PANELS.EXPOSURE CATEGORY BASSUMED BRACED WALL NOTES2' - 0"24' - 6"21' - 6"6' - 0"26' - 6"27' - 6"54' - 0"52' - 0"2-9 1/2" LSL5x7 PSL2-2x10PORTAL FRAMEW/ HOLD-DOWNSMFG. ROOF TRUSSES@ 24" O.C.0' - 10"SET F.P. 18" A.F.F.14P4260/A24 TR.O. 3' -6" x 7' -0"H.H. 8' -0"14P4260/A24 TR.O. 3' -6" x 7' -0"H.H. 8' -0"14P4260/A24 TR.O. 3' -6" x 7' -0"H.H. 8' -0"104860 SLR.O. 4' -0" x 5' -0"H.H. 6' -10"14P4260/A24 TR.O. 3' -6" x 7' -0"H.H. 8' -0"14P4260/A24 TR.O. 3' -6" x 7' -0"H.H. 8' -0"14P4260/A24 TR.O. 3' -6" x 7' -0"H.H. 8' -0"63618 PICR.O. 3' -0" x 1' -6"H.H. 8' -0"63618 PICR.O. 3' -0" x 1' -6"H.H. 8' -0"104860 SLR.O. 4' -0" x 5' -0"H.H. 6' -10"137260 SLR.O. 6' -0" x 5' -0"H.H. 6' -10"137260 SLR.O. 6' -0" x 5' -0"H.H. 6' -10"94848 PIC TEMPR.O. 4' -0" x 4' -0"H.H. 11' -10"2' - 0"50' - 0"52' - 0"33' - 2"18' - 10"42424 AWN FIXEDR.O. 2' -0" x 2' -0"H.H. 6' -10"82/8 x 6/8 FIRE RATEDR.O. 2' -10" x 6' -10 1/4"52/6 x 6/8R.O. 2' -8" x 6' -11"72/8 x 6/8R.O. 2' -10" x 6' -11"22' - 0"4' VANITY2x65' - 4"10' - 5"CS-WSP4' - 0" B.W.P.MFG. ROOF TRUSSES@ 24" O.C.1/4" = 1'-0"A-4031MAIN FLOOR PLANTHE IDEAS, DESIGNS, DRAWINGS AND SPECIFICATIONS REPRESENTED HEREIN ARE AND SHALL REMAIN THE EXCLUSIVE COPYRIGHT PROPERTY OF ONETENTEN HOMES. NO PART THERE OF SHALL BE USED, COPIED, OR DISCLOSED IN CONNECTION WITH ANY WORK OR PROJECT OTHER THAN THE SPECIFIED PROJECT FOR WHICH THEY HAVE BEEN PREPARED WITHOUT THE WRITTEN CONSENT OF ONETENTEN HOMES.THE PLANS FURNISHED HEREIN WERE PREPARED UPON REQUEST BY DRAFTSPERSONS WHO ARE NOT REGISTERED ARCHITECTS OR ENGINEERS. ONETENTEN HOMES ASSUMES NO RESPONSIBILITY FOR STRUCTURAL OR DIMENSIONAL ERRORS OR OMISSIONS.THE CONTRACTOR AND/OR OWNER MUST VERIFY AND CHECK ALL NOTES DETAILS, ELEVATIONS, SECTIONS AND FLOOR PLANS AND NOTIFY ONETENTEN HOMES OF ANY ERRORS OR OMISSIONS PRIOR TO THE START OF CONSTRUCTION. NO WARRANTIES ARE EXPRESSED OR IMPLIED INCLUDING COMPLIANCE OF THIS PLAN WITH APPLICABLE BUILDING CODE REQUIREMENTS. THE SELECTION AND APPLICATION OF CORRECT STRUCTURAL MATERIALS IS THE RESPONSIBILITY OF THE BUILDER, THE OWNER OR THE USER OF THESE PLANS.P.O. BOX 3915411 LAKERS LANE, SUITE 204NISSWA, MN 56468PH (612) 327-7582NORTHHOUSE-RD.COMDATEFINISHED SQUARE FEETPROJECTSHEETUPPER:MAIN:LOWER:RELEASEDREV. 1REV. 2REV. 3REV. 4REV. 5PLATE HEIGHTSUPPER:MAIN:POUR:UNSPECIFIED HEADERS TO BE 2-2x10 W/ 2 TRIMMERS10" MIN. STAIR TREAD DEPTH & 7 3/4" MAX STAIR RISER HEIGHTALL ANGLES ARE 45 DEGREES UNLESS NOTED OTHERWISEALL EXTERIOR DIMENSIONS ARE TO OUTSIDE OF SHEATHING, CONCRETE OR FOUNDATION INSULATIONBRAINERD LAKESTWIN CITIES3000 COUNTY ROAD 42 WEST, SUITE 202 BURNSVILLE, MN 55337PH (952)-953-4000ONETENTENHOMES.COMTOTAL:5/3/2021 9:39:40 AMTHE SPELBRINK RESIDENCEL7, B7 -PHEASANT RUN 5TH17870 ECLIPSE AVENUELAKEVILLE, MN 55044A-403OTT2175.3.21 CB1699145310753.30.21 TP8'- 1 /18"9'- 1 /18"8'-4" POUR4227THE CONNORBWPsAboveFANVerify loads with girdertruss specs, may requireremoval of top plates atbearing due to crushing.
DN 17RBEDROOM #4BATHBEDROOM #3OWNER'S SUITEHALLEN SUITE7'-6" VANITYCLOSETR & SH. @ 65"BEDROOM #211' - 0"13' - 6"17' - 6"6' - 0"36' - 0"2' - 0"2' - 0"17' - 0"15' - 0"10' - 0"42' - 0"42' - 0"22/4 x 6/8R.O. 2' -6" x 6' -11"CLOSET42/4 x 6/8 PKTR.O. 4' -10" x 6' -11"22/4 x 6/8R.O. 2' -6" x 6' -11"52/6 x 6/8R.O. 2' -8" x 6' -11"2' LINEN3' VANITY3' VANITY52/6 x 6/8R.O. 2' -8" x 6' -11"22/4 x 6/8R.O. 2' -6" x 6' -11"CLOSET #2OWNER'SCLOSETTILESHOWER42" WALL W/GLASS PANEL5' - 9"5' - 3"4' - 7"4' - 7"4' - 4"8' - 9"8' - 9"20' - 0"16' - 0"5' - 7 7/8"6' - 9"4' - 7 1/8"7' - 6"7' - 6"40' - 0"6' - 0"11' - 6 7/8"28' - 5 1/8"16' - 0"4' - 0"4' - 0"12' - 0"5' - 0"5' - 0"1' - 8"30' - 4"10' - 8"6' - 8 1/4"4' - 0"4' - 1 3/4"6' - 1 3/4"2' - 11"7' - 5 1/4"14' - 8"3' - 7"6' - 7 1/4"4' - 7 3/4"7' - 1"5' - 5"14' - 5"1' - 8"3' - 6"6' - 4"5' - 5"2' - 8"12' - 0"2' - 0"6' - 10"2' - 0"1' - 7 1/4"4' - 9"4' - 4 1/2"5' - 9 1/4"R & SH. @ 65"CO DET.SMOKEDET.SMOKEDET.SMOKEDET.MFG. ROOF TRUSSES@ 24" O.C.MFG. ROOF TRUSSES@24" O.C.ATTICACCESS2-2x102-9 1/2" LSL2-2x6 EA. SIDEKNEE WALL W/ 14" PAINTED SPINDLESR & SH. @ 48"32/4 x 6/8 OPG.62/6 x 6/8 PKTR.O. 5' -2" x 6' -11"4' VANITY48" F.G. SHWR52/6 x 6/8R.O. 2' -8" x 6' -11"2x6BATHTYP.2' - 0"2-2x102-2x102-2x102-2x102-2x1072/8 x 6/8R.O. 2' -10" x 6' -11"SMOKEDET.CS-WSP4' - 0" B.W.P.CS-WSP2' - 3" B.W.P.CS-WSP2' - 3" B.W.P.CS-WSP3' - 0" B.W.P.CS-WSP3' - 0" B.W.P.CS-WSP3' - 0" B.W.P.CS-WSP4' - 0" B.W.P.CS-WSP3' - 0" B.W.P.CS-WSP6' - 0" B.W.P.CS-WSP3' - 0" B.W.P.CS-WSP3' - 0" B.W.P.CS-WSP3' - 0" B.W.P.CS-WSP4' - 0" B.W.P.CS-WSP4' - 0" B.W.P.3-2x10R & SH.R & SH. @ 65"22/4 x 6/8R.O. 2' -6" x 6' -11"42/4 x 6/8 PKTR.O. 4' -10" x 6' -11"52/6 x 6/8R.O. 2' -8" x 6' -11"2' - 4"2' - 2"CURB2'-6" LINEN62/6 x 6/8 PKTR.O. 5' -2" x 6' -11"2' - 0"6' - 0"SMOKEDET.2' - 8"2x6R & SH.ACCENT WALLACCENT WALL46' - 0"46' - 0"3' - 3"0' - 6"3' x 5' TUB W/ 6" TILEDECKCS-WSP4' - 0" B.W.P.CONTROLHEADSINKWASHERDRYERCS-WSP METHOD BRACED WALL PANELS-8d NAILS 6" ON EDGES & 12" IN FIELD,STACK BETWEEN LEVELS WHEN POSSIBLE.USE (3) 16d NAILS NEXT TO EACHSTUD TO SECURE WALL DOWN TO DECKAT BRACED WALL PANELS.EXPOSURE CATEGORY BASSUMED BRACED WALL NOTESCLOSETDOUBLE FRAME PLUMBING WALL5' F.G.TUB/SHWR224-48-2460 SLR.O. 8' -0" x 5' -0"H.H. 6' -10"126048 SLR.O. 5' -0" x 4' -0"H.H. 6' -10"32424 AWNR.O. 2' -0" x 2' -0"H.H. 6' -10"52424-3 AWN FIXEDR.O. 6' -0" x 2' -0"H.H. 6' -10"116042 SLR.O. 5' -0" x 3' -6"H.H. 6' -10"32424 AWNR.O. 2' -0" x 2' -0"H.H. 6' -10"32424 AWNR.O. 2' -0" x 2' -0"H.H. 6' -10"124-48-2448 SLR.O. 8' -0" x 4' -0"H.H. 6' -10"74824 AWN FIXED TEMP.R.O. 4' -0" x 2' -0"H.H. 6' -10"22/4 x 6/8R.O. 2' -6" x 6' -11"72/8 x 6/8R.O. 2' -10" x 6' -11"LAUNDRY2-2x105' - 4"7' - 10 1/2"3' - 3 1/2"THE IDEAS, DESIGNS, DRAWINGS AND SPECIFICATIONS REPRESENTED HEREIN ARE AND SHALL REMAIN THE EXCLUSIVE COPYRIGHT PROPERTY OF ONETENTEN HOMES. NO PART THERE OF SHALL BE USED, COPIED, OR DISCLOSED IN CONNECTION WITH ANY WORK OR PROJECT OTHER THAN THE SPECIFIED PROJECT FOR WHICH THEY HAVE BEEN PREPARED WITHOUT THE WRITTEN CONSENT OF ONETENTEN HOMES.THE PLANS FURNISHED HEREIN WERE PREPARED UPON REQUEST BY DRAFTSPERSONS WHO ARE NOT REGISTERED ARCHITECTS OR ENGINEERS. ONETENTEN HOMES ASSUMES NO RESPONSIBILITY FOR STRUCTURAL OR DIMENSIONAL ERRORS OR OMISSIONS.THE CONTRACTOR AND/OR OWNER MUST VERIFY AND CHECK ALL NOTES DETAILS, ELEVATIONS, SECTIONS AND FLOOR PLANS AND NOTIFY ONETENTEN HOMES OF ANY ERRORS OR OMISSIONS PRIOR TO THE START OF CONSTRUCTION. NO WARRANTIES ARE EXPRESSED OR IMPLIED INCLUDING COMPLIANCE OF THIS PLAN WITH APPLICABLE BUILDING CODE REQUIREMENTS. THE SELECTION AND APPLICATION OF CORRECT STRUCTURAL MATERIALS IS THE RESPONSIBILITY OF THE BUILDER, THE OWNER OR THE USER OF THESE PLANS.P.O. BOX 3915411 LAKERS LANE, SUITE 204NISSWA, MN 56468PH (612) 327-7582NORTHHOUSE-RD.COMDATEFINISHED SQUARE FEETPROJECTSHEETUPPER:MAIN:LOWER:RELEASEDREV. 1REV. 2REV. 3REV. 4REV. 5PLATE HEIGHTSUPPER:MAIN:POUR:UNSPECIFIED HEADERS TO BE 2-2x10 W/ 2 TRIMMERS10" MIN. STAIR TREAD DEPTH & 7 3/4" MAX STAIR RISER HEIGHTALL ANGLES ARE 45 DEGREES UNLESS NOTED OTHERWISEALL EXTERIOR DIMENSIONS ARE TO OUTSIDE OF SHEATHING, CONCRETE OR FOUNDATION INSULATIONBRAINERD LAKESTWIN CITIES3000 COUNTY ROAD 42 WEST, SUITE 202 BURNSVILLE, MN 55337PH (952)-953-4000ONETENTENHOMES.COMTOTAL:5/3/2021 9:39:42 AMTHE SPELBRINK RESIDENCEL7, B7 -PHEASANT RUN 5TH17870 ECLIPSE AVENUELAKEVILLE, MN 55044A-404OTT2175.3.21 CB1699145310753.30.21 TP8'- 1 /18"9'- 1 /18"8'-4" POUR4227THE CONNOR1/4" = 1'-0"A-4041UPPER FLOOR PLANFANFANFANFAN-Min. 15" clearance to anyobstruction from center ofW.C., 24" in front(typ).
WATCH DOG WATER PROOFCOATING FROM FOOTING TOSILL SEALER6 MIL POLY V.B., OVERLAPEDGES MIN. 12" & TAPE.SEAL ALL OPENINGS4" MIN. LAYER3/4" RIVER ROCK3 1/2" CONCRETE SLABANCHOR BOLTPER CODETRT'D 2x8 SILL PLATEW/ CLOSED CELL ROLLSILL SEALERGRADEGRANULAR FILL4" DRAIN TILEW/ SILT SOCK1" FOAMBOARD (R-5) INSULATIONW/ ACOUSTICAL SEALANT @ TOP& BOTTOM EDGES, BETWEEN INSUL.& SLAB & AT ALL VERTICAL EDGES(ONLY WHEN REQUIRED BY CODE)POLYURETHANE CAULKOR ELASTOMERICSEALANT @ ALL JOINTSMIN.0' - 6"VERIFY FLOOR SYSTEMWITH FLOOR PLANS3/4" T&GSUBFLOORLOWER FLOOR PLATE HEIGHT8' - 2"MAIN FLOOR PLATE HEIGHT9' - 1 1/8"6 MIL. V.B.1/2" GYP. BD.VERIFY FLOOR SYSTEMWITH FLOOR PLANSUPPER FLOOR PLATE HEIGHT8' - 1 1/8"6 MIL. V.B.1/2" GYP. BD.3/4" T&GSUBFLOOR6 MIL. V.B.2x6 STUDS @ 16" O.C.W/ R-21 F.G. INSULATION2x6 STUDS @ 16" O.C.W/ R-21 F.G. INSULATION8'-4"(H) x 8"(W) POUREDCONCRETE FOUND. WALL ON20" x 8" CONCRETE FTG'S.REBAR PER CODE.1/2" OSBSHEATHINGTYVEK (OR EQUAL)ROLL HOUSE WRAPSIDING, VERIFYW/ ELEVATIONS5/8" GYP. BD.5/8" GYP. BD.VENTED ALUMINUMSOFFIT PANELSICE & WATER GUARDFROM EAVE TO 2'-0"MIN. OVER STRUCTUREVENT CHUTES & WIND WASH@ EACH TRUSS SPACEASPHALT SHINGLES W/15# ROLL FELT UNDER1/2" OSB ROOF SHEATHINGMFG. ROOFTRUSSES @ 24" O.C.ATTIC VENTINGAS PER CODER-49 MIN. BLOWNATTIC INSULATIONALUMINUM FASCIA W/2x6 SUB FASCIAALUMINUMDRIP EDGERIM JOISTRIM JOISTR-20 MIN. SPRAYFOAM INSULATION,COVER FOUNDATION WALLGMX THERMAL DRAINAGE BOARD(R-10) INSULATIONDRYVIT INSULATIONPROTECTION FROM SIDINGTO 6" BELOW GRADE5000 PSI CONCRETE@ ALL FOOTINGS*OUTSIDE OF FOUNDATION TO ALIGN WITH OUTSIDE OF SHEATINGR-20 MIN. SPRAYFOAM INSULATIONALL DUCT WORK & PLUMBING TO REMAIN ABOVE INSULATIONTYVEK OR EQUALHOUSE WRAP5/8" TYPE 'X'GYP. BD., TAPE &MUD ALL SEAMS1" RIGID INSULATION3/4" T&G SUBFLOORR-30 MIN.BLOWN INSULATIONFLOOR TRUSS1' - 4"2x4 @ BOTTOM1x3 TYP.2x4 @ TOPSTAINED WOOD TYP.SOFFITFRONTSIDETOP VIEW1' - 4"1' - 4"FRAMING4x4 POST1' - 4"18" OVERHANGS & 12" RAKES TYP.STANDARD ENERGY HEELS @ 8:128" / 12"8" / 12"8" / 12"8" / 12"7" / 12"8" / 12"8" / 12"8" / 12"8" / 12"8 ROOF VENTS REQUIREDSTANDARD ENERGY HEELS @ 7:12 W/ 8:12 TO MATCH FASCIA LINE3 ROOF VENTS REQUIRED1 ROOF VENT REQUIRED7" / 12"7" / 12"7" / 12"FASTEN TOP PLATE TOHEADER W/ (2) ROWS OF16d SINKER NAILS @3" O.C. TYP.MIN. 3/8" WOODSTRUCTURAL PANELSHEATHINGSECTIONTENSION STRAP PERTABLE R602.10.6.4(ON OPPOSITE SIDEOF SHEATHING)IF NEEDED, PANELSPLICE EDGES SHALLOCCUR OVER AND BENAILED TO COMMONBLOCKING WITHINMIDDLE 24" OF WALLMID-HEIGHT. ONEROW OF 3" O.C.NAILING IS REQUIREDIN EACH PANEL EDGE.TYPICAL PORTALFRAME CONSTRUCTION.MIN. DOUBLE 2x4 POST(KING AND JACK STUD).NUMBER OF JACK STUDSPER TABLES R502.5(1) & (2).MIN. 1000 LB HOLD-DOWNDEVICE (EMBEDDED INTOCONCRETE & NAILEDINTO FRAMING)FRONT ELEVATIONMIN. FOOTING SIZE UNDER OPENING IS12" X 12". A TURNED DOWN SLAB SHALLBE PERMITTED AT DOOR OPENINGS.MIN. (1) 5/8" DIA. ANCHOR BOLDINSTALLED PER R403.1.6 W/2" X 2" X 3/16" PLATE WASHER.MIN. REINFORCING OF FOUNDATION,ONE #4 BAR TOP & BOTTOM OFFOOTING. LAP BARS 15" MINIMUM.MIN. (2) 4200 LB STRAP-TYPE HOLD-DOWNS (EMBEDDED INTO CONCRETEAND NAILED INTO FRAMING)MIN. LENGTH OF PANELPER TABLE R602.10.5MIN. DOUBLE 2x4 FRAMING COVEREDWITH MIN. 3/8" THICK WOOD STRUCTURALPANEL SHEATHING W/ 8d COMMON ORGALVANIZED BOX NAILS AT 3" O.C. INALL FRAMING (STUDS, BLOCKING AND SILLS) TYP.HEADER TO JACK STUD STRAP PERTABLE R602.10.6.4 ON BOTH SIDES OFOPENING OPPOSITE SIDE OF SHEATHINGFASTEN SHEATHING TO HEADER WITH8d COMMON OR GALVANIZED BOXNAILS IN 3" GRID PATTERN AS SHOWNMIN. 3" X 11 1/4" NET HEADER,STEEL HEADER PROHIBITED10' - 0" MAX. HEIGHTHEIGHTPONYWALL12' - 0" MAX TOTAL WALL HEIGHTEXTENT OF HEADER WITH SINGLE PORTALFRAME (ONE BRACED WALL PANEL)2' - 0" TO 18' - 0" FINISHED WIDTH OFOPENING FOR SINGLE OR DOUBLE PORTAL2x6 STUDS @ 16" O.C. ONHALF-HIGH 6" BLOCK ON16" x 8" CONCRETE FTG'S.REBAR PER CODE.TRT'D SILL PLATEPOLYURETHANE CAULKOR ELASTOMERICSEALANT @ ALL JOINTSSLEEVE EVERY10'-0" MIN.6 MIL POLY V.B., OVERLAPEDGES MIN. 12" & TAPE.SEAL ALL OPENINGS4" MIN. LAYER3/4" RIVER ROCK3 1/2" CONCRETE SLABANCHOR BOLTPER CODE5000 PSI CONCRETE@ ALL FOOTINGSANCHOR BOLTPER CODETRT'D 2x6 SILL PLATEW/ ROLL SILL SEALER1" FOAMBOARD (R-5) INSULATIONW/ ACOUSTICAL SEALANT @ TOP& BOTTOM EDGES, BETWEEN INSUL.& SLAB & AT ALL VERTICAL EDGES(ONLY WHEN REQUIRED BY CODE)3/4" T&GSUBFLOOR6 MIL. V.B.1/2" GYP. BD.2x6 STUDS @ 16" O.C.W/ R-20 F.G. INSULATION5/8" TYPE 'X' GYP BOARD,TAPE & MUD ALL SEAMSRIM JOISTR-20 MIN. SPRAYFOAM INSULATIONGMX THERMAL DRAINAGE BOARD(R-10) INSULATION5/8" GYP. BD., TAPE& MUD ALL SEAMSSLOPED CONCRETESLAB, FLASH AS REQ'DAT HOUSE WALL0' - 4"POUREDFND. WALLWATCH DOG WATER PROOFCOATING FROM FOOTING TOSILL SEALERVERIFY FLOOR SYSTEMWITH FLOOR PLANSANCHOR BOLTPER CODETRT'D 2x6 SILL PLATEW/ ROLL SILL SEALER1" FOAMBOARD (R-5) INSULATIONW/ ACOUSTICAL SEALANT @ TOP& BOTTOM EDGES, BETWEEN INSUL.& SLAB & AT ALL VERTICAL EDGES(ONLY WHEN REQUIRED BY CODE)VERIFY FLOOR SYSTEMWITH FLOOR PLANS3/4" T&GSUBFLOOR6 MIL. V.B.1/2" GYP. BD.2x6 STUDS @ 16" O.C.W/ R-20 F.G. INSULATION1/2" OSBSHEATHINGRIM JOISTR-20 MIN. SPRAYFOAM INSULATIONGMX THERMAL DRAINAGE BOARD(R-10) INSULATION5/8" GYP. BD., TAPE& MUD ALL SEAMSSLOPED CONCRETESTOOP, FLASH AS REQ'DAT HOUSE WALLPOUREDFND. WALLWATCH DOG WATER PROOFCOATING FROM FOOTING TOSILL SEALERSIDING, VERIFYW/ ELEVATIONSTYVEK (OR EQUAL) ROLL HOUSE WRAP0' - 2"FROM SHEATHING TOOUTSIDE OF FOUNDATIONWATER PROOF COATINGFROM FOOTING TOINSIDE OF WALL6 MIL POLY V.B., OVERLAPEDGES MIN. 12" & TAPE.SEAL ALL OPENINGS4" MIN. LAYER3/4" RIVER ROCK3 1/2" CONCRETE SLABANCHOR BOLTPER CODETYPICAL 2x6EXTERIOR WALLTRT'D 2x6 SILL PLATEW/ ROLL SILL SEALERGRADEMIN.0' - 6"GRANULAR FILL4" DRAIN TILEW/ SILT SOCK:LOOKOUT WALL:2x6 STUDS @ 16" O.C. ON3'-6"(H) x 8"(W) POUREDCONCRETE FOUND. WALL ON20" x 8" CONCRETE FTG.REBAR PER CODEPOLYURETHANE CAULKOR ELASTOMERICSEALANT @ ALL JOINTS1" FOAMBOARD (R-5) INSULATIONW/ ACOUSTICAL SEALANT @ TOP& BOTTOM EDGES, BETWEEN INSUL.& SLAB & AT ALL VERTICAL EDGESINSULATION & SEALANT TOBE CONT. OVER WALL2" FOAMBOARD(R-10) INSULATIONINSULATION PROTECTIONFROM SIDING TO6" BELOW GRADE5000 PSI CONCRETE@ ALL FOOTINGS*OUTSIDE OF FOUNDATION TO ALIGN WITHOUTSIDE OF SHEATHING6 MIL POLY V.B., OVERLAPEDGES MIN. 12" & TAPE.SEAL ALL OPENINGS4" MIN. LAYER3/4" RIVER ROCK3 1/2" CONCRETE SLABANCHOR BOLTPER CODETYPICAL 2x6EXTERIOR WALLTRT'D 2x6 SILL PLATEW/ ROLL SILL SEALERGRADEGRANULAR FILL:WALKOUT WALL:2x6 STUDS @ 16" O.C. ON3'-6"(H) x 8"(W) POUREDCONCRETE FOUND. WALLW/ 2" x 4" INT. LEDGE ON20" x 8" CONCRETE FTG'S.REBAR PER CODE.POLYURETHANE CAULKOR ELASTOMERICSEALANT @ ALL JOINTSMIN.0' - 6"5000 PSI CONCRETE@ ALL FOOTINGS2" FOAMBOARD(R-10) INSULATION4" DRAIN TILEW/ SILT SOCKWATER PROOF COATING FROM FOOTING TOSILL SEALERTHE IDEAS, DESIGNS, DRAWINGS AND SPECIFICATIONS REPRESENTED HEREIN ARE AND SHALL REMAIN THE EXCLUSIVE COPYRIGHT PROPERTY OF ONETENTEN HOMES. NO PART THERE OF SHALL BE USED, COPIED, OR DISCLOSED IN CONNECTION WITH ANY WORK OR PROJECT OTHER THAN THE SPECIFIED PROJECT FOR WHICH THEY HAVE BEEN PREPARED WITHOUT THE WRITTEN CONSENT OF ONETENTEN HOMES.THE PLANS FURNISHED HEREIN WERE PREPARED UPON REQUEST BY DRAFTSPERSONS WHO ARE NOT REGISTERED ARCHITECTS OR ENGINEERS. ONETENTEN HOMES ASSUMES NO RESPONSIBILITY FOR STRUCTURAL OR DIMENSIONAL ERRORS OR OMISSIONS.THE CONTRACTOR AND/OR OWNER MUST VERIFY AND CHECK ALL NOTES DETAILS, ELEVATIONS, SECTIONS AND FLOOR PLANS AND NOTIFY ONETENTEN HOMES OF ANY ERRORS OR OMISSIONS PRIOR TO THE START OF CONSTRUCTION. NO WARRANTIES ARE EXPRESSED OR IMPLIED INCLUDING COMPLIANCE OF THIS PLAN WITH APPLICABLE BUILDING CODE REQUIREMENTS. THE SELECTION AND APPLICATION OF CORRECT STRUCTURAL MATERIALS IS THE RESPONSIBILITY OF THE BUILDER, THE OWNER OR THE USER OF THESE PLANS.P.O. BOX 3915411 LAKERS LANE, SUITE 204NISSWA, MN 56468PH (612) 327-7582NORTHHOUSE-RD.COMDATEFINISHED SQUARE FEETPROJECTSHEETUPPER:MAIN:LOWER:RELEASEDREV. 1REV. 2REV. 3REV. 4REV. 5PLATE HEIGHTSUPPER:MAIN:POUR:UNSPECIFIED HEADERS TO BE 2-2x10 W/ 2 TRIMMERS10" MIN. STAIR TREAD DEPTH & 7 3/4" MAX STAIR RISER HEIGHTALL ANGLES ARE 45 DEGREES UNLESS NOTED OTHERWISEALL EXTERIOR DIMENSIONS ARE TO OUTSIDE OF SHEATHING, CONCRETE OR FOUNDATION INSULATIONBRAINERD LAKESTWIN CITIES3000 COUNTY ROAD 42 WEST, SUITE 202 BURNSVILLE, MN 55337PH (952)-953-4000ONETENTENHOMES.COMTOTAL:5/3/2021 9:39:43 AMTHE SPELBRINK RESIDENCEL7, B7 -PHEASANT RUN 5TH17870 ECLIPSE AVENUELAKEVILLE, MN 55044A-501OTT2175.3.21 CB1699145310753.30.21 TP8'- 1 /18"9'- 1 /18"8'-4" POUR4227THE CONNORWINDOW SCHEDULETYPE MARK MANUFACTURER MODEL COUNT UNIT ROUGH WIDTH ROUGH HEIGHT HEAD HEIGHT1 WINDSOR NEXT DIMENSION 1 24-48-2448 SL 8' - 0" 4' - 0" 6' - 10"2 WINDSOR NEXT DIMENSION 2 24-48-2460 SL 8' - 0" 5' - 0" 6' - 10"3 WINDSOR NEXT DIMENSION 3 2424 AWN 2' - 0" 2' - 0" 6' - 10"4 WINDSOR NEXT DIMENSION 1 2424 AWN FIXED 2' - 0" 2' - 0"6' - 10"5 WINDSOR NEXT DIMENSION 1 2424-3 AWN FIXED 6' - 0" 2' - 0" 6' - 10"6 WINDSOR NEXT DIMENSION 2 3618 PIC 3' - 0" 1' - 6" 8' - 0"7 WINDSOR NEXT DIMENSION 1 4824 AWN FIXED TEMP. 4' - 0" 2' - 0" 6' - 10"8 WINDSOR NEXT DIMENSION 1 4836 PIC 4' - 0" 3' - 0" 1' - 8 1/4"9 WINDSOR NEXT DIMENSION 1 4848 PIC TEMP 4' - 0" 4' - 0" 11' - 10"10 WINDSOR NEXT DIMENSION 2 4860 SL 4' - 0" 5' - 0" 6' - 10"11 WINDSOR NEXT DIMENSION 1 6042 SL 5' - 0" 3' - 6" 6' - 10"12 WINDSOR NEXT DIMENSION 2 6048 SL 5' - 0" 4' - 0" 6' - 10"13 WINDSOR NEXT DIMENSION 2 7260 SL 6' - 0" 5' - 0" 6' - 10"14 WINDSOR NEXT DIMENSION 6 P4260/A24 T 3' - 6" 7' - 0" 8' - 0"3/8" = 1'-0"A-5012TYP. POURED WALL SECTION1/2" = 1'-0"A-5013GARAGE CEILING3" MIN. ABS OR PVC GASTIGHT PIPE FROM SUBSLAB TO MIN.12" ABOVE ROOF, MUST BE RUN THRU CONDITIONED SPACE.PIPE CAN BE CONNECTED TO SUMP SYSTEM OR HAVE"T" FITTING (MIN. 10'-0" EA. WAY) IN GRAVEL UNDER SLAB.END OF PIPE MUST BE MIN. 10'-0" AWAY FROM ANY WINDOW OROTHER OPENING THAT IS LESS THAN 2'-0" BELOW END OF PIPE. END OF PIPE MUST ALSO BE MIN. 10'-0" AWAY FROM ANYWINDOW OR OTHER OPENING IN ADJOINING OR ADJACENT BUILDINGS.SUFFICIENT SPACE MUST BE LEFT AROUND PIPE IN ATTIC SPACETO ADD FAN. SPACE MUST BE MIN. ∅24" CENTERED ON AXIS OFPIPE W/ MIN. 3'-0" VERTICAL SPACE.A SINGLE PIPE CAN BE USED IF ALL SOIL GASES IN DWELLING CANFLOW FREELY BETWEEN ALL LEVELS OF FOUNDATION. THIS INCLUDESINTERIOR FOOTINGS & OTHER BARRIERS IF AIRFLOW HAS BEEN ESTABLISHED.LABEL THE VENT PIPE AT LEAST ONCE PER FLOOR AND IN ACCESSIBLE ATTICSWITH "RADON REDUCTION SYSTEM".ONE ELECTRICAL RECEPTACLE IS REQUIRED IN THE ATTIC NEARTHE VENT PIPE FOR OPT. FAN.:PASSIVE RADON SYSTEM:DOOR SCHEDULETYPE MARK DOOR SIZE ROUGH WIDTH ROUGH WIDTH COUNT COMMENTS1 1/6 x 6/8 1' - 8" 6' - 11" 12 2/4 x 6/8 2' - 6" 6' - 11" 93 2/4 x 6/8 OPG.14 2/4 x 6/8 PKT 4' - 10" 6' - 11" 25 2/6 x 6/8 2' - 8" 6' - 11" 86 2/6 x 6/8 PKT 5' - 2" 6' - 11" 27 2/8 x 6/8 2' - 10" 6' - 11" 48 2/8 x 6/8 FIRE RATED 2' - 10" 6' - 10 1/4" 19 3/0 x 6/8 FULL VIEW110 3/0 x 6/8 OPG.111 3/0 x 6/8 W/ 12" D.S. SL'S112 4/0 x 6/8 4' - 2" 6' - 11" 113 5/0 x 6/8 5' - 2" 6' - 11" 114 8' x 8' O.H. GARAGE DOOR115 9/0 x 6/8 SLIDER 9' - 0" 6' - 8" 116 16' x 8' O.H. GARAGE DOOR1ROOM FINISH SCHEDULEFLOOR NAME FLOOR FINISH AREA CEILING HEIGHT COMMENTSLOWER FLOOR MECHANICAL / STORAGE CONCRETE 218 SF 8' - 2" .LOWER FLOOR BEDROOM #5 CARPET 163 SF 8' - 2"LOWER FLOOR BATH VINYL 42 SF 8' - 2"LOWER FLOOR STAIRWAY CARPET 76 SF 8' - 2"LOWER FLOOR RECREATION ROOM CARPET 724 SF 8' - 2"LOWER FLOOR STORAGE CARPET 58 SF 8' - 2" FINISHEDMAIN FLOOR KITCHEN WOOD 251 SF 9' - 1 1/8" .MAIN FLOOR DINING ROOM WOOD 183 SF 9' - 1 1/8" .MAIN FLOOR GREAT ROOM CARPET 239 SF 9' - 1 1/8" .MAIN FLOOR FOYER WOOD 131 SF 9' - 1 1/8" .MAIN FLOOR OFFICE WOOD 114 SF 9' - 1 1/8" .MAIN FLOOR MUD RM. VINYL 58 SF 9' - 1 1/8" .MAIN FLOOR PORCH CONCRETE 128 SF 9' - 1 1/8" .MAIN FLOOR GARAGE CONCRETE 769 SF 10' - 9 3/8"MAIN FLOOR POWDER VINYL 50 SF 9' - 1 1/8" .MAIN FLOOR FLEX ROOM CARPET 143 SF 9' - 1 1/8"MAIN FLOOR PANTRY VINYL 27 SF 9' - 1 1/8" .MAIN FLOOR CLOSET VINYL 28 SF 9' - 1 1/8" .MAIN FLOOR STAIRWAY CARPET 84 SF 9' - 1 1/8"UPPER FLOOR BEDROOM #4 CARPET 199 SF 8' - 1 1/8" .UPPER FLOOR BATH VINYL 97 SF 8' - 1 1/8" .UPPER FLOOR BEDROOM #3 CARPET 149 SF 8' - 1 1/8" .UPPER FLOOR OWNER'S SUITE CARPET 241 SF 8' - 1 1/8" 12" BOX VAULTUPPER FLOOR HALL CARPET 141 SF 8' - 1 1/8" .UPPER FLOOR BEDROOM #2 CARPET 157 SF 8' - 1 1/8" .UPPER FLOOR EN SUITE TILE 173 SF 8' - 1 1/8" .UPPER FLOOR CLOSET CARPET 27 SF 8' - 1 1/8" .UPPER FLOOR CLOSET CARPET 28 SF 8' - 1 1/8" .UPPER FLOOR LAUNDRY VINYL 52 SF 8' - 1 1/8" .UPPER FLOOR CLOSET #2 CARPET 42 SF 8' - 1 1/8" .UPPER FLOOR OWNER'S CLOSET CARPET 75 SF 8' - 1 1/8" .UPPER FLOOR BATH VINYL 56 SF 8' - 1 1/8" .UPPER FLOOR CLOSET CARPET 15 SF 8' - 1 1/8"1/2" = 1'-0"A-5011TYP. COLUMN1/8" = 1'-0"A-5014ROOF PLAN3/8" = 1'-0"A-5015METHOD PFH - PORTAL FRAME WITH HOLD-DOWNS1/2" = 1'-0"A-5016BEARING WALL SECTION1/2" = 1'-0"A-5017TYP. HOUSE/GARAGE WALL1/2" = 1'-0"A-5018TYP. HOUSE/STOOP WALL1/2" = 1'-0"A-5019TYP. POURED LOOKOUT SECTION1/2" = 1'-0"A-50110TYP. POURED WALKOUT SECTION
Upper Level
Member Name Results Current Solution Comments
Bedroom # 2 Window Passed 2 piece(s) 2 x 10 Spruce-Pine-Fir No. 1 / No. 2
Owner's Suite Window Passed 2 piece(s) 2 x 10 Spruce-Pine-Fir No. 1 / No. 2
Owner's Bathroom Window Passed 3 piece(s) 2 x 10 Spruce-Pine-Fir No. 1 / No. 2
Bedroom #4 Window Passed 2 piece(s) 2 x 10 Spruce-Pine-Fir No. 1 / No. 2
Bedroom 3 & 4 Bath Window Passed 2 piece(s) 2 x 10 Spruce-Pine-Fir No. 1 / No. 2
Bedroom# 3 WIC Passed 2 piece(s) 2 x 10 Spruce-Pine-Fir No. 1 / No. 2
Bedroom #3 Window Passed 2 piece(s) 2 x 10 Spruce-Pine-Fir No. 1 / No. 2
Stairs Window Passed 2 piece(s) 1 3/4" x 9 1/2" 1.55E TimberStrand® LSL
Main Level
Member Name Results Current Solution Comments
Great Room Back Window Passed 2 piece(s) 2 x 10 Spruce-Pine-Fir No. 1 / No. 2
Dining Room Side Window Passed 2 piece(s) 2 x 10 Spruce-Pine-Fir No. 1 / No. 2
Dining Room Back Window Passed 2 piece(s) 2 x 10 Spruce-Pine-Fir No. 1 / No. 2
Bathroom Window Passed 3 piece(s) 2 x 10 Spruce-Pine-Fir No. 1 / No. 2
Mudroom Door Passed 2 piece(s) 2 x 10 Spruce-Pine-Fir No. 1 / No. 2
Front Porch FLR Beam Passed 2 piece(s) 1 3/4" x 9 1/2" 1.55E TimberStrand® LSL
Garage 8' OHD Passed 2 piece(s) 2 x 12 Spruce-Pine-Fir No. 1 / No. 2
Garage 16' OHD Passed 3 piece(s) 1 3/4" x 24" 2.0E Microllam® LVL
Front Door Hdr Passed 2 piece(s) 2 x 10 Spruce-Pine-Fir No. 1 / No. 2
Office Window Passed 2 piece(s) 2 x 10 Spruce-Pine-Fir No. 1 / No. 2
Flush Beam over Foyer (H)Passed 2 piece(s) 1 3/4" x 11 7/8" 1.55E TimberStrand® LSL
Flush Beam Stairway down Passed 2 piece(s) 1 3/4" x 11 7/8" 1.55E TimberStrand® LSL
Great Room Side Window Passed 3 piece(s) 2 x 10 Spruce-Pine-Fir No. 1 / No. 2
Dining Room Flush Beam Passed 3 piece(s) 1 3/4" x 14" 2.0E Microllam® LVL
Stair Landing Window Passed 2 piece(s) 2 x 10 Spruce-Pine-Fir No. 1 / No. 2
Dining Room Hall Door Passed 2 piece(s) 2 x 10 Spruce-Pine-Fir No. 1 / No. 2
Stairs Flush Beam Passed 2 piece(s) 2 x 10 Spruce-Pine-Fir No. 1 / No. 2
Mudroom Window Passed 3 piece(s) 2 x 10 Spruce-Pine-Fir No. 1 / No. 2
Flush Flex (V)Passed 4 piece(s) 1 3/4" x 20" 2.0E Microllam® LVL
Flex Window Rear Passed 2 piece(s) 1 3/4" x 9 1/2" 1.55E TimberStrand® LSL
Drop Front Porch (H)Passed 2 piece(s) 2 x 10 Spruce-Pine-Fir No. 1 / No. 2
Drop Front Porch (V)Passed 2 piece(s) 2 x 10 Spruce-Pine-Fir No. 1 / No. 2
Lower Level
Member Name Results Current Solution Comments
Family Room Flush Beam Passed 3 piece(s) 1 3/4" x 14" 2.0E Microllam® LVL
Bedroom# 5 Window Passed 3 piece(s) 1 3/4" x 9 1/2" 1.55E TimberStrand® LSL
Door Hdr Mech/Storage Passed 2 piece(s) 2 x 10 Spruce-Pine-Fir No. 1 / No. 2
Bump-out Window Passed 2 piece(s) 1 3/4" x 9 1/2" 2.0E Microllam® LVL
Family Room Window Passed 2 piece(s) 1 3/4" x 11 7/8" 1.55E TimberStrand® LSL
17870 Eclipse Ave, Lakeville, MN
JOB SUMMARY REPORT
ForteWEB Software Operator Job Notes 4/28/2021 8:33:07 PM UTCJeffrey Doty, Design Supervisor
Lyman Lumber Company
(952) 470-4866
jeff_doty@lymanlumber.com
ForteWEB v3.1
File Name: 17870 Eclipse Ave, Lakeville, MN
Topaz - Connor
17870 Eclipse Ave, Lakeville, MN
4/28/21; #24806
Page 1 / 39
Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern)
Member Reaction (lbs)748 @ 1 1/2"3825 (3.00")Passed (20%)--1.0 D + 1.0 S (All Spans)
Shear (lbs)470 @ 1' 1/4"2872 Passed (16%)1.15 1.0 D + 1.0 S (All Spans)
Moment (Ft-lbs)937 @ 2' 9"3946 Passed (24%)1.15 1.0 D + 1.0 S (All Spans)
Live Load Defl. (in)0.006 @ 2' 9"0.175 Passed (L/999+)--1.0 D + 1.0 S (All Spans)
Total Load Defl. (in)0.017 @ 2' 9"0.262 Passed (L/999+)--1.0 D + 1.0 S (All Spans)
System : Wall
Member Type : Header
Building Use : Residential
Building Code : IBC 2018
Design Methodology : ASD
•Deflection criteria: LL (L/360) and TL (L/240).
•Allowed moment does not reflect the adjustment for the beam stability factor.
•Applicable calculations are based on NDS.
Bearing Length Loads to Supports (lbs)
Supports Total Available Required Dead Snow Total Accessories
1 - Trimmer - SPF 3.00"3.00"1.50"459 289 748 None
2 - Trimmer - SPF 3.00"3.00"1.50"459 289 748 None
•Maximum allowable bracing intervals based on applied load.
Lateral Bracing Bracing Intervals Comments
Top Edge (Lu)5' 6" o/c
Bottom Edge (Lu)5' 6" o/c
Dead Snow
Vertical Loads Location (Side)Tributary Width (0.90)(1.15)Comments
0 - Self Weight (PLF)0 to 5' 6"N/A 7.0 --
1 - Uniform (PSF)0 to 5' 6"3'20.0 35.0 Snow - Main
2 - Uniform (PSF)0 to 5' 6"1'100.0 -Wall - Gable
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties
related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is
responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387
and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to
www.weyerhaeuser.com/woodproducts/document-library.
The product application, input design loads, dimensions and support information have been provided by plan dated 3/30/21.
Weyerhaeuser Notes
All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal.
MEMBER REPORT PASSED
Upper Level, Bedroom # 2 Window
2 piece(s) 2 x 10 Spruce-Pine-Fir No. 1 / No. 2
ForteWEB Software Operator Job Notes 4/28/2021 8:33:07 PM UTCJeffrey Doty, Design Supervisor
Lyman Lumber Company
(952) 470-4866
jeff_doty@lymanlumber.com
ForteWEB v3.1, Engine: V8.1.6.2, Data: V8.0.1.0
File Name: 17870 Eclipse Ave, Lakeville, MN
Topaz - Connor
17870 Eclipse Ave, Lakeville, MN
4/28/21; #24806
Page 2 / 39
Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern)
Member Reaction (lbs)1156 @ 1 1/2"3825 (3.00")Passed (30%)--1.0 D + 1.0 S (All Spans)
Shear (lbs)878 @ 1' 1/4"2872 Passed (31%)1.15 1.0 D + 1.0 S (All Spans)
Moment (Ft-lbs)2314 @ 4' 3"3946 Passed (59%)1.15 1.0 D + 1.0 S (All Spans)
Live Load Defl. (in)0.040 @ 4' 3"0.275 Passed (L/999+)--1.0 D + 1.0 S (All Spans)
Total Load Defl. (in)0.102 @ 4' 3"0.412 Passed (L/967)--1.0 D + 1.0 S (All Spans)
System : Wall
Member Type : Header
Building Use : Residential
Building Code : IBC 2018
Design Methodology : ASD
•Deflection criteria: LL (L/360) and TL (L/240).
•Allowed moment does not reflect the adjustment for the beam stability factor.
•Applicable calculations are based on NDS.
Bearing Length Loads to Supports (lbs)
Supports Total Available Required Dead Snow Total Accessories
1 - Trimmer - SPF 3.00"3.00"1.50"710 446 1156 None
2 - Trimmer - SPF 3.00"3.00"1.50"710 446 1156 None
•Maximum allowable bracing intervals based on applied load.
Lateral Bracing Bracing Intervals Comments
Top Edge (Lu)8' 6" o/c
Bottom Edge (Lu)8' 6" o/c
Dead Snow
Vertical Loads Location (Side)Tributary Width (0.90)(1.15)Comments
0 - Self Weight (PLF)0 to 8' 6"N/A 7.0 --
1 - Uniform (PSF)0 to 8' 6"3'20.0 35.0 Snow - Main
2 - Uniform (PSF)0 to 8' 6"1'100.0 -Wall - Gable
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties
related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is
responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387
and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to
www.weyerhaeuser.com/woodproducts/document-library.
The product application, input design loads, dimensions and support information have been provided by plan dated 3/30/21.
Weyerhaeuser Notes
All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal.
MEMBER REPORT PASSED
Upper Level, Owner's Suite Window
2 piece(s) 2 x 10 Spruce-Pine-Fir No. 1 / No. 2
ForteWEB Software Operator Job Notes 4/28/2021 8:33:07 PM UTCJeffrey Doty, Design Supervisor
Lyman Lumber Company
(952) 470-4866
jeff_doty@lymanlumber.com
ForteWEB v3.1, Engine: V8.1.6.2, Data: V8.0.1.0
File Name: 17870 Eclipse Ave, Lakeville, MN
Topaz - Connor
17870 Eclipse Ave, Lakeville, MN
4/28/21; #24806
Page 3 / 39
Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern)
Member Reaction (lbs)2870 @ 1 1/2"5738 (3.00")Passed (50%)--1.0 D + 1.0 S (All Spans)
Shear (lbs)1568 @ 1' 1/4"4308 Passed (36%)1.15 1.0 D + 1.0 S (All Spans)
Moment (Ft-lbs)2880 @ 2' 3"5919 Passed (49%)1.15 1.0 D + 1.0 S (All Spans)
Live Load Defl. (in)0.014 @ 2' 3"0.142 Passed (L/999+)--1.0 D + 1.0 S (All Spans)
Total Load Defl. (in)0.023 @ 2' 3"0.213 Passed (L/999+)--1.0 D + 1.0 S (All Spans)
System : Wall
Member Type : Header
Building Use : Residential
Building Code : IBC 2018
Design Methodology : ASD
•Deflection criteria: LL (L/360) and TL (L/240).
•Allowed moment does not reflect the adjustment for the beam stability factor.
•Applicable calculations are based on NDS.
Bearing Length Loads to Supports (lbs)
Supports Total Available Required Dead Snow Total Accessories
1 - Trimmer - SPF 3.00"3.00"1.50"1059 1811 2870 None
2 - Trimmer - SPF 3.00"3.00"1.50"1059 1811 2870 None
•Maximum allowable bracing intervals based on applied load.
Lateral Bracing Bracing Intervals Comments
Top Edge (Lu)4' 6" o/c
Bottom Edge (Lu)4' 6" o/c
Dead Snow
Vertical Loads Location (Side)Tributary Width (0.90)(1.15)Comments
0 - Self Weight (PLF)0 to 4' 6"N/A 10.6 --
1 - Uniform (PSF)0 to 4' 6"23'20.0 35.0 Snow - Main
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties
related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is
responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387
and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to
www.weyerhaeuser.com/woodproducts/document-library.
The product application, input design loads, dimensions and support information have been provided by plan dated 3/30/21.
Weyerhaeuser Notes
All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal.
MEMBER REPORT PASSED
Upper Level, Owner's Bathroom Window
3 piece(s) 2 x 10 Spruce-Pine-Fir No. 1 / No. 2
ForteWEB Software Operator Job Notes 4/28/2021 8:33:07 PM UTCJeffrey Doty, Design Supervisor
Lyman Lumber Company
(952) 470-4866
jeff_doty@lymanlumber.com
ForteWEB v3.1, Engine: V8.1.6.2, Data: V8.0.1.0
File Name: 17870 Eclipse Ave, Lakeville, MN
Topaz - Connor
17870 Eclipse Ave, Lakeville, MN
4/28/21; #24806
Page 4 / 39
Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern)
Member Reaction (lbs)1156 @ 1 1/2"3825 (3.00")Passed (30%)--1.0 D + 1.0 S (All Spans)
Shear (lbs)878 @ 1' 1/4"2872 Passed (31%)1.15 1.0 D + 1.0 S (All Spans)
Moment (Ft-lbs)2314 @ 4' 3"3946 Passed (59%)1.15 1.0 D + 1.0 S (All Spans)
Live Load Defl. (in)0.040 @ 4' 3"0.275 Passed (L/999+)--1.0 D + 1.0 S (All Spans)
Total Load Defl. (in)0.102 @ 4' 3"0.412 Passed (L/967)--1.0 D + 1.0 S (All Spans)
System : Wall
Member Type : Header
Building Use : Residential
Building Code : IBC 2018
Design Methodology : ASD
•Deflection criteria: LL (L/360) and TL (L/240).
•Allowed moment does not reflect the adjustment for the beam stability factor.
•Applicable calculations are based on NDS.
Bearing Length Loads to Supports (lbs)
Supports Total Available Required Dead Snow Total Accessories
1 - Trimmer - SPF 3.00"3.00"1.50"710 446 1156 None
2 - Trimmer - SPF 3.00"3.00"1.50"710 446 1156 None
•Maximum allowable bracing intervals based on applied load.
Lateral Bracing Bracing Intervals Comments
Top Edge (Lu)8' 6" o/c
Bottom Edge (Lu)8' 6" o/c
Dead Snow
Vertical Loads Location (Side)Tributary Width (0.90)(1.15)Comments
0 - Self Weight (PLF)0 to 8' 6"N/A 7.0 --
1 - Uniform (PSF)0 to 8' 6"3'20.0 35.0 Snow - Main
2 - Uniform (PSF)0 to 8' 6"1'100.0 -Wall - Gable
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties
related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is
responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387
and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to
www.weyerhaeuser.com/woodproducts/document-library.
The product application, input design loads, dimensions and support information have been provided by plan dated 3/30/21.
Weyerhaeuser Notes
All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal.
MEMBER REPORT PASSED
Upper Level, Bedroom #4 Window
2 piece(s) 2 x 10 Spruce-Pine-Fir No. 1 / No. 2
ForteWEB Software Operator Job Notes 4/28/2021 8:33:07 PM UTCJeffrey Doty, Design Supervisor
Lyman Lumber Company
(952) 470-4866
jeff_doty@lymanlumber.com
ForteWEB v3.1, Engine: V8.1.6.2, Data: V8.0.1.0
File Name: 17870 Eclipse Ave, Lakeville, MN
Topaz - Connor
17870 Eclipse Ave, Lakeville, MN
4/28/21; #24806
Page 5 / 39
Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern)
Member Reaction (lbs)306 @ 0 1913 (1.50")Passed (16%)--1.0 D + 1.0 S (All Spans)
Shear (lbs)62 @ 10 3/4"2872 Passed (2%)1.15 1.0 D + 1.0 S (All Spans)
Moment (Ft-lbs)172 @ 1' 1 1/2"3946 Passed (4%)1.15 1.0 D + 1.0 S (All Spans)
Live Load Defl. (in)0.000 @ 1' 1 1/2"0.075 Passed (L/999+)--1.0 D + 1.0 S (All Spans)
Total Load Defl. (in)0.001 @ 1' 1 1/2"0.112 Passed (L/999+)--1.0 D + 1.0 S (All Spans)
System : Wall
Member Type : Header
Building Use : Residential
Building Code : IBC 2018
Design Methodology : ASD
•Deflection criteria: LL (L/360) and TL (L/240).
•Allowed moment does not reflect the adjustment for the beam stability factor.
•Applicable calculations are based on NDS.
Bearing Length Loads to Supports (lbs)
Supports Total Available Required Dead Snow Total Accessories
1 - Trimmer - SPF 1.50"1.50"1.50"188 118 306 None
2 - Trimmer - SPF 1.50"1.50"1.50"188 118 306 None
•Maximum allowable bracing intervals based on applied load.
Lateral Bracing Bracing Intervals Comments
Top Edge (Lu)2' 3" o/c
Bottom Edge (Lu)2' 3" o/c
Dead Snow
Vertical Loads Location (Side)Tributary Width (0.90)(1.15)Comments
0 - Self Weight (PLF)0 to 2' 3"N/A 7.0 --
1 - Uniform (PSF)0 to 2' 3"3'20.0 35.0 Snow - Main
2 - Uniform (PSF)0 to 2' 3"1'100.0 -Wall - Gable
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties
related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is
responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387
and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to
www.weyerhaeuser.com/woodproducts/document-library.
The product application, input design loads, dimensions and support information have been provided by plan dated 3/30/21.
Weyerhaeuser Notes
All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal.
MEMBER REPORT PASSED
Upper Level, Bedroom 3 & 4 Bath Window
2 piece(s) 2 x 10 Spruce-Pine-Fir No. 1 / No. 2
ForteWEB Software Operator Job Notes 4/28/2021 8:33:07 PM UTCJeffrey Doty, Design Supervisor
Lyman Lumber Company
(952) 470-4866
jeff_doty@lymanlumber.com
ForteWEB v3.1, Engine: V8.1.6.2, Data: V8.0.1.0
File Name: 17870 Eclipse Ave, Lakeville, MN
Topaz - Connor
17870 Eclipse Ave, Lakeville, MN
4/28/21; #24806
Page 6 / 39
Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern)
Member Reaction (lbs)306 @ 0 1913 (1.50")Passed (16%)--1.0 D + 1.0 S (All Spans)
Shear (lbs)62 @ 10 3/4"2872 Passed (2%)1.15 1.0 D + 1.0 S (All Spans)
Moment (Ft-lbs)172 @ 1' 1 1/2"3946 Passed (4%)1.15 1.0 D + 1.0 S (All Spans)
Live Load Defl. (in)0.000 @ 1' 1 1/2"0.075 Passed (L/999+)--1.0 D + 1.0 S (All Spans)
Total Load Defl. (in)0.001 @ 1' 1 1/2"0.112 Passed (L/999+)--1.0 D + 1.0 S (All Spans)
System : Wall
Member Type : Header
Building Use : Residential
Building Code : IBC 2018
Design Methodology : ASD
•Deflection criteria: LL (L/360) and TL (L/240).
•Allowed moment does not reflect the adjustment for the beam stability factor.
•Applicable calculations are based on NDS.
Bearing Length Loads to Supports (lbs)
Supports Total Available Required Dead Snow Total Accessories
1 - Trimmer - SPF 1.50"1.50"1.50"188 118 306 None
2 - Trimmer - SPF 1.50"1.50"1.50"188 118 306 None
•Maximum allowable bracing intervals based on applied load.
Lateral Bracing Bracing Intervals Comments
Top Edge (Lu)2' 3" o/c
Bottom Edge (Lu)2' 3" o/c
Dead Snow
Vertical Loads Location (Side)Tributary Width (0.90)(1.15)Comments
0 - Self Weight (PLF)0 to 2' 3"N/A 7.0 --
1 - Uniform (PSF)0 to 2' 3"3'20.0 35.0 Snow - Main
2 - Uniform (PSF)0 to 2' 3"1'100.0 -Wall - Gable
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties
related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is
responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387
and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to
www.weyerhaeuser.com/woodproducts/document-library.
The product application, input design loads, dimensions and support information have been provided by plan dated 3/30/21.
Weyerhaeuser Notes
All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal.
MEMBER REPORT PASSED
Upper Level, Bedroom# 3 WIC
2 piece(s) 2 x 10 Spruce-Pine-Fir No. 1 / No. 2
ForteWEB Software Operator Job Notes 4/28/2021 8:33:07 PM UTCJeffrey Doty, Design Supervisor
Lyman Lumber Company
(952) 470-4866
jeff_doty@lymanlumber.com
ForteWEB v3.1, Engine: V8.1.6.2, Data: V8.0.1.0
File Name: 17870 Eclipse Ave, Lakeville, MN
Topaz - Connor
17870 Eclipse Ave, Lakeville, MN
4/28/21; #24806
Page 7 / 39
Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern)
Member Reaction (lbs)748 @ 1 1/2"3825 (3.00")Passed (20%)--1.0 D + 1.0 S (All Spans)
Shear (lbs)470 @ 1' 1/4"2872 Passed (16%)1.15 1.0 D + 1.0 S (All Spans)
Moment (Ft-lbs)937 @ 2' 9"3946 Passed (24%)1.15 1.0 D + 1.0 S (All Spans)
Live Load Defl. (in)0.006 @ 2' 9"0.175 Passed (L/999+)--1.0 D + 1.0 S (All Spans)
Total Load Defl. (in)0.017 @ 2' 9"0.262 Passed (L/999+)--1.0 D + 1.0 S (All Spans)
System : Wall
Member Type : Header
Building Use : Residential
Building Code : IBC 2018
Design Methodology : ASD
•Deflection criteria: LL (L/360) and TL (L/240).
•Allowed moment does not reflect the adjustment for the beam stability factor.
•Applicable calculations are based on NDS.
Bearing Length Loads to Supports (lbs)
Supports Total Available Required Dead Snow Total Accessories
1 - Trimmer - SPF 3.00"3.00"1.50"459 289 748 None
2 - Trimmer - SPF 3.00"3.00"1.50"459 289 748 None
•Maximum allowable bracing intervals based on applied load.
Lateral Bracing Bracing Intervals Comments
Top Edge (Lu)5' 6" o/c
Bottom Edge (Lu)5' 6" o/c
Dead Snow
Vertical Loads Location (Side)Tributary Width (0.90)(1.15)Comments
0 - Self Weight (PLF)0 to 5' 6"N/A 7.0 --
1 - Uniform (PSF)0 to 5' 6"3'20.0 35.0 Snow - Main
2 - Uniform (PSF)0 to 5' 6"1'100.0 -Wall - Gable
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties
related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is
responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387
and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to
www.weyerhaeuser.com/woodproducts/document-library.
The product application, input design loads, dimensions and support information have been provided by plan dated 3/30/21.
Weyerhaeuser Notes
All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal.
MEMBER REPORT PASSED
Upper Level, Bedroom #3 Window
2 piece(s) 2 x 10 Spruce-Pine-Fir No. 1 / No. 2
ForteWEB Software Operator Job Notes 4/28/2021 8:33:07 PM UTCJeffrey Doty, Design Supervisor
Lyman Lumber Company
(952) 470-4866
jeff_doty@lymanlumber.com
ForteWEB v3.1, Engine: V8.1.6.2, Data: V8.0.1.0
File Name: 17870 Eclipse Ave, Lakeville, MN
Topaz - Connor
17870 Eclipse Ave, Lakeville, MN
4/28/21; #24806
Page 8 / 39
Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern)
Member Reaction (lbs)4251 @ 1 1/2"7613 (3.00")Passed (56%)--1.0 D + 1.0 S (All Spans)
Shear (lbs)2923 @ 1' 1/2"7902 Passed (37%)1.15 1.0 D + 1.0 S (All Spans)
Moment (Ft-lbs)6564 @ 3' 4"11985 Passed (55%)1.15 1.0 D + 1.0 S (All Spans)
Live Load Defl. (in)0.098 @ 3' 4"0.214 Passed (L/788)--1.0 D + 1.0 S (All Spans)
Total Load Defl. (in)0.155 @ 3' 4"0.321 Passed (L/497)--1.0 D + 1.0 S (All Spans)
System : Wall
Member Type : Header
Building Use : Residential
Building Code : IBC 2018
Design Methodology : ASD
•Deflection criteria: LL (L/360) and TL (L/240).
•Allowed moment does not reflect the adjustment for the beam stability factor.
Bearing Length Loads to Supports (lbs)
Supports Total Available Required Dead Snow Total Accessories
1 - Trimmer - SPF 3.00"3.00"1.68"1568 2683 4251 None
2 - Trimmer - SPF 3.00"3.00"1.68"1568 2683 4251 None
•Maximum allowable bracing intervals based on applied load.
Lateral Bracing Bracing Intervals Comments
Top Edge (Lu)6' 8" o/c
Bottom Edge (Lu)6' 8" o/c
Dead Snow
Vertical Loads Location (Side)Tributary Width (0.90)(1.15)Comments
0 - Self Weight (PLF)0 to 6' 8"N/A 10.4 --
1 - Uniform (PSF)0 to 6' 8"23'20.0 35.0 Snow - Main
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties
related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is
responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387
and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to
www.weyerhaeuser.com/woodproducts/document-library.
The product application, input design loads, dimensions and support information have been provided by plan dated 3/30/21.
Weyerhaeuser Notes
All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal.
MEMBER REPORT PASSED
Upper Level, Stairs Window
2 piece(s) 1 3/4" x 9 1/2" 1.55E TimberStrand® LSL
ForteWEB Software Operator Job Notes 4/28/2021 8:33:07 PM UTCJeffrey Doty, Design Supervisor
Lyman Lumber Company
(952) 470-4866
jeff_doty@lymanlumber.com
ForteWEB v3.1, Engine: V8.1.6.2, Data: V8.0.1.0
File Name: 17870 Eclipse Ave, Lakeville, MN
Topaz - Connor
17870 Eclipse Ave, Lakeville, MN
4/28/21; #24806
Page 9 / 39
Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern)
Member Reaction (lbs)5089 @ 7' 8 1/4"5738 (4.50")Passed (89%)--1.0 D + 1.0 L (Adj Spans)
Shear (lbs)1718 @ 6' 8 3/4"2498 Passed (69%)1.00 1.0 D + 1.0 L (Adj Spans)
Moment (Ft-lbs)-1721 @ 7' 8 1/4"3431 Passed (50%)1.00 1.0 D + 1.0 L (Adj Spans)
Live Load Defl. (in)0.006 @ 9' 7 7/8"0.127 Passed (L/999+)--1.0 D + 1.0 L (Alt Spans)
Total Load Defl. (in)0.008 @ 9' 8 3/4"0.191 Passed (L/999+)--1.0 D + 1.0 L (Alt Spans)
System : Wall
Member Type : Header
Building Use : Residential
Building Code : IBC 2018
Design Methodology : ASD
•Deflection criteria: LL (L/360) and TL (L/240).
•Allowed moment does not reflect the adjustment for the beam stability factor.
•Applicable calculations are based on NDS.
Bearing Length Loads to Supports (lbs)
Supports Total Available Required Dead Floor Live Snow Total Accessories
1 - Trimmer - SPF 1.50"1.50"1.50"713 557/-93 277 1547/-
93 None
2 - Trimmer - SPF 4.50"4.50"2.41"1423 1653 321 3397 None
3 - Trimmer - SPF 4.50"4.50"3.99"2334 2756 560 5650 None
4 - Trimmer - SPF 1.50"1.50"1.50"572 748/-127 157 1477/-
127 None
•Maximum allowable bracing intervals based on applied load.
Lateral Bracing Bracing Intervals Comments
Top Edge (Lu)11' 6" o/c
Bottom Edge (Lu)11' 6" o/c
Dead Floor Live Snow
Vertical Loads Location (Side)Tributary Width (0.90)(1.00)(1.15)Comments
0 - Self Weight (PLF)0 to 11' 6"N/A 7.0 ----
1 - Uniform (PSF)0 to 7'8'15.0 40.0 -floor
2 - Uniform (PSF)7' to 11' 6"11'15.0 40.0 -floor
3 - Uniform (PLF)0 to 11' 6"N/A 80.0 --wall
4 - Uniform (PSF)5' to 11' 6"3'20.0 -35.0 Snow - Main
5 - Uniform (PSF)5' to 11' 6"1'100.0 --Wall - Gable
6 - Point (lb)0 N/A 459 -289
Linked from:
Bedroom# 2
Window, Support 1
7 - Point (lb)5'N/A 459 -289
Linked from:
Bedroom# 2
Window, Support 2
8 - Point (lb)7'N/A 500 990 -
Linked from: Main
Level FLR Girder,
Support 2
All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal.
MEMBER REPORT PASSED
Main Level, Great Room Back Window
2 piece(s) 2 x 10 Spruce-Pine-Fir No. 1 / No. 2
ForteWEB Software Operator Job Notes 4/28/2021 8:33:07 PM UTCJeffrey Doty, Design Supervisor
Lyman Lumber Company
(952) 470-4866
jeff_doty@lymanlumber.com
ForteWEB v3.1, Engine: V8.1.6.2, Data: V8.0.1.0
File Name: 17870 Eclipse Ave, Lakeville, MN
Topaz - Connor
17870 Eclipse Ave, Lakeville, MN
4/28/21; #24806
Page 10 / 39
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties
related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is
responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387
and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to
www.weyerhaeuser.com/woodproducts/document-library.
The product application, input design loads, dimensions and support information have been provided by plan dated 3/30/21.
Weyerhaeuser Notes
ForteWEB Software Operator Job Notes 4/28/2021 8:33:07 PM UTCJeffrey Doty, Design Supervisor
Lyman Lumber Company
(952) 470-4866
jeff_doty@lymanlumber.com
ForteWEB v3.1, Engine: V8.1.6.2, Data: V8.0.1.0
File Name: 17870 Eclipse Ave, Lakeville, MN
Topaz - Connor
17870 Eclipse Ave, Lakeville, MN
4/28/21; #24806
Page 11 / 39
Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern)
Member Reaction (lbs)1327 @ 0 1913 (1.50")Passed (69%)--1.0 D + 1.0 S (All Spans)
Shear (lbs)768 @ 10 3/4"2872 Passed (27%)1.15 1.0 D + 1.0 S (All Spans)
Moment (Ft-lbs)1410 @ 2' 1 1/2"3946 Passed (36%)1.15 1.0 D + 1.0 S (All Spans)
Live Load Defl. (in)0.009 @ 2' 1 1/2"0.142 Passed (L/999+)--1.0 D + 1.0 S (All Spans)
Total Load Defl. (in)0.017 @ 2' 1 1/2"0.213 Passed (L/999+)--1.0 D + 1.0 S (All Spans)
System : Wall
Member Type : Header
Building Use : Residential
Building Code : IBC 2018
Design Methodology : ASD
•Deflection criteria: LL (L/360) and TL (L/240).
•Allowed moment does not reflect the adjustment for the beam stability factor.
•Applicable calculations are based on NDS.
Bearing Length Loads to Supports (lbs)
Supports Total Available Required Dead Floor Live Snow Total Accessories
1 - Trimmer - SPF 1.50"1.50"1.50"621 85 707 1413 None
2 - Trimmer - SPF 1.50"1.50"1.50"621 85 707 1413 None
•Maximum allowable bracing intervals based on applied load.
Lateral Bracing Bracing Intervals Comments
Top Edge (Lu)4' 3" o/c
Bottom Edge (Lu)4' 3" o/c
Dead Floor Live Snow
Vertical Loads Location (Side)Tributary Width (0.90)(1.00)(1.15)Comments
0 - Self Weight (PLF)0 to 4' 3"N/A 7.0 ----
1 - Uniform (PSF)0 to 4' 3"9' 6"20.0 -35.0 roof
2 - Uniform (PSF)0 to 4' 3"1'15.0 40.0 -Floor - Upper Level
3 - Uniform (PSF)0 to 4' 3"1'80.0 --Wall - Upper Level
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties
related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is
responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387
and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to
www.weyerhaeuser.com/woodproducts/document-library.
The product application, input design loads, dimensions and support information have been provided by plan dated 3/30/21.
Weyerhaeuser Notes
All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal.
MEMBER REPORT PASSED
Main Level, Dining Room Side Window
2 piece(s) 2 x 10 Spruce-Pine-Fir No. 1 / No. 2
ForteWEB Software Operator Job Notes 4/28/2021 8:33:07 PM UTCJeffrey Doty, Design Supervisor
Lyman Lumber Company
(952) 470-4866
jeff_doty@lymanlumber.com
ForteWEB v3.1, Engine: V8.1.6.2, Data: V8.0.1.0
File Name: 17870 Eclipse Ave, Lakeville, MN
Topaz - Connor
17870 Eclipse Ave, Lakeville, MN
4/28/21; #24806
Page 12 / 39
Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern)
Member Reaction (lbs)1314 @ 1 1/2"3825 (3.00")Passed (34%)--1.0 D + 1.0 S (Alt Spans)
Shear (lbs)1065 @ 2' 11 3/4"2872 Passed (37%)1.15 1.0 D + 1.0 S (Adj Spans)
Moment (Ft-lbs)1421 @ 1' 10 1/2"3946 Passed (36%)1.15 1.0 D + 1.0 S (Alt Spans)
Live Load Defl. (in)0.004 @ 1' 10 13/16"0.127 Passed (L/999+)--1.0 D + 1.0 S (Alt Spans)
Total Load Defl. (in)0.010 @ 1' 10 11/16"0.191 Passed (L/999+)--1.0 D + 1.0 S (Alt Spans)
System : Wall
Member Type : Header
Building Use : Residential
Building Code : IBC 2018
Design Methodology : ASD
•Deflection criteria: LL (L/360) and TL (L/240).
•Allowed moment does not reflect the adjustment for the beam stability factor.
•Applicable calculations are based on NDS.
Bearing Length Loads to Supports (lbs)
Supports Total Available Required Dead Snow Total Accessories
1 - Trimmer - SPF 3.00"3.00"1.50"775 540 1315 None
2 - Trimmer - SPF 4.50"4.50"1.50"1011 789 1800 None
3 - Trimmer - SPF 4.50"4.50"1.50"1011 789 1800 None
4 - Trimmer - SPF 3.00"3.00"1.50"775 540 1315 None
•Maximum allowable bracing intervals based on applied load.
Lateral Bracing Bracing Intervals Comments
Top Edge (Lu)11' 9" o/c
Bottom Edge (Lu)11' 9" o/c
Dead Snow
Vertical Loads Location (Side)Tributary Width (0.90)(1.15)Comments
0 - Self Weight (PLF)0 to 11' 9"N/A 7.0 --
1 - Uniform (PSF)0 to 11' 9"3'15.0 35.0 floor
2 - Uniform (PLF)0 to 11' 9"N/A 80.0 -wall
3 - Uniform (PSF)0 to 1' 10 1/2"3'20.0 35.0 Snow - Main
4 - Uniform (PSF)9' 10 1/2" to 11' 9"3'20.0 35.0 Snow - Main
5 - Uniform (PSF)0 to 1' 10 1/2"1'100.0 -Wall - Gable
6 - Uniform (PSF)9' 10 1/2" to 11' 9"1'100.0 -Wall - Gable
7 - Point (lb)1' 10 1/2"N/A 710 446
Linked from:
Owner's Suite
Window, Support 1
8 - Point (lb)9' 10 1/2"N/A 710 446
Linked from:
Owner's Suite
Window, Support 2
All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal.
MEMBER REPORT PASSED
Main Level, Dining Room Back Window
2 piece(s) 2 x 10 Spruce-Pine-Fir No. 1 / No. 2
ForteWEB Software Operator Job Notes 4/28/2021 8:33:07 PM UTCJeffrey Doty, Design Supervisor
Lyman Lumber Company
(952) 470-4866
jeff_doty@lymanlumber.com
ForteWEB v3.1, Engine: V8.1.6.2, Data: V8.0.1.0
File Name: 17870 Eclipse Ave, Lakeville, MN
Topaz - Connor
17870 Eclipse Ave, Lakeville, MN
4/28/21; #24806
Page 13 / 39
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties
related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is
responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387
and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to
www.weyerhaeuser.com/woodproducts/document-library.
The product application, input design loads, dimensions and support information have been provided by plan dated 3/30/21.
Weyerhaeuser Notes
ForteWEB Software Operator Job Notes 4/28/2021 8:33:07 PM UTCJeffrey Doty, Design Supervisor
Lyman Lumber Company
(952) 470-4866
jeff_doty@lymanlumber.com
ForteWEB v3.1, Engine: V8.1.6.2, Data: V8.0.1.0
File Name: 17870 Eclipse Ave, Lakeville, MN
Topaz - Connor
17870 Eclipse Ave, Lakeville, MN
4/28/21; #24806
Page 14 / 39
Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern)
Member Reaction (lbs)2907 @ 0 2869 (1.50")Passed (101%)--1.0 D + 1.0 S (All Spans)
Shear (lbs)1474 @ 10 3/4"4308 Passed (34%)1.15 1.0 D + 1.0 S (All Spans)
Moment (Ft-lbs)1796 @ 7 1/2"5919 Passed (30%)1.15 1.0 D + 1.0 S (All Spans)
Live Load Defl. (in)0.002 @ 1' 1 1/8"0.075 Passed (L/999+)--1.0 D + 1.0 S (All Spans)
Total Load Defl. (in)0.004 @ 1' 1 1/8"0.112 Passed (L/999+)--1.0 D + 1.0 S (All Spans)
System : Wall
Member Type : Header
Building Use : Residential
Building Code : IBC 2018
Design Methodology : ASD
•Deflection criteria: LL (L/360) and TL (L/240).
•Allowed moment does not reflect the adjustment for the beam stability factor.
•Applicable calculations are based on NDS.
Bearing Length Loads to Supports (lbs)
Supports Total Available Required Dead Floor Live Snow Total Accessories
1 - Trimmer - SPF 1.50"1.50"1.52"1127 45 1780 2952 None
2 - Trimmer - SPF 1.50"1.50"1.50"843 45 1339 2227 None
•Maximum allowable bracing intervals based on applied load.
Lateral Bracing Bracing Intervals Comments
Top Edge (Lu)2' 3" o/c
Bottom Edge (Lu)2' 3" o/c
Dead Floor Live Snow
Vertical Loads Location (Side)Tributary Width (0.90)(1.00)(1.15)Comments
0 - Self Weight (PLF)0 to 2' 3"N/A 10.6 ----
1 - Uniform (PSF)0 to 2' 3"1'15.0 40.0 -floor
2 - Uniform (PLF)0 to 2' 3"N/A 80.0 --wall
3 - Uniform (PSF)7 1/2" to 2' 3"23'18.0 -35.0 roof
4 - Point (lb)7 1/2"N/A 1059 -1811
Linked from: Wdw
Hdr Owner's Bath,
Support 2
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties
related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is
responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387
and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to
www.weyerhaeuser.com/woodproducts/document-library.
The product application, input design loads, dimensions and support information have been provided by plan dated 3/30/21.
Weyerhaeuser Notes
All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal.
MEMBER REPORT PASSED
Main Level, Bathroom Window
3 piece(s) 2 x 10 Spruce-Pine-Fir No. 1 / No. 2
ForteWEB Software Operator Job Notes 4/28/2021 8:33:07 PM UTCJeffrey Doty, Design Supervisor
Lyman Lumber Company
(952) 470-4866
jeff_doty@lymanlumber.com
ForteWEB v3.1, Engine: V8.1.6.2, Data: V8.0.1.0
File Name: 17870 Eclipse Ave, Lakeville, MN
Topaz - Connor
17870 Eclipse Ave, Lakeville, MN
4/28/21; #24806
Page 15 / 39
Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern)
Member Reaction (lbs)2303 @ 1 1/2"3825 (3.00")Passed (60%)--1.0 D + 1.0 L (All Spans)
Shear (lbs)893 @ 1' 1/4"2498 Passed (36%)1.00 1.0 D + 1.0 L (All Spans)
Moment (Ft-lbs)1642 @ 1' 8"3431 Passed (48%)1.00 1.0 D + 1.0 L (All Spans)
Live Load Defl. (in)0.007 @ 1' 8"0.103 Passed (L/999+)--1.0 D + 1.0 L (All Spans)
Total Load Defl. (in)0.010 @ 1' 8"0.154 Passed (L/999+)--1.0 D + 1.0 L (All Spans)
System : Wall
Member Type : Header
Building Use : Residential
Building Code : IBC 2018
Design Methodology : ASD
•Deflection criteria: LL (L/360) and TL (L/240).
•Allowed moment does not reflect the adjustment for the beam stability factor.
•Applicable calculations are based on NDS.
Bearing Length Loads to Supports (lbs)
Supports Total Available Required Dead Floor Live Total Accessories
1 - Trimmer - SPF 3.00"3.00"1.81"637 1667 2304 None
2 - Trimmer - SPF 3.00"3.00"1.81"637 1667 2304 None
•Maximum allowable bracing intervals based on applied load.
Lateral Bracing Bracing Intervals Comments
Top Edge (Lu)3' 4" o/c
Bottom Edge (Lu)3' 4" o/c
Dead Floor Live
Vertical Loads Location (Side)Tributary Width (0.90)(1.00)Comments
0 - Self Weight (PLF)0 to 3' 4"N/A 7.0 --
1 - Uniform (PSF)0 to 3' 4"25'15.0 40.0 floor
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties
related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is
responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387
and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to
www.weyerhaeuser.com/woodproducts/document-library.
The product application, input design loads, dimensions and support information have been provided by plan dated 3/30/21.
Weyerhaeuser Notes
All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal.
MEMBER REPORT PASSED
Main Level, Mudroom Door
2 piece(s) 2 x 10 Spruce-Pine-Fir No. 1 / No. 2
ForteWEB Software Operator Job Notes 4/28/2021 8:33:07 PM UTCJeffrey Doty, Design Supervisor
Lyman Lumber Company
(952) 470-4866
jeff_doty@lymanlumber.com
ForteWEB v3.1, Engine: V8.1.6.2, Data: V8.0.1.0
File Name: 17870 Eclipse Ave, Lakeville, MN
Topaz - Connor
17870 Eclipse Ave, Lakeville, MN
4/28/21; #24806
Page 16 / 39
Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern)
Member Reaction (lbs)2338 @ 7' 11"8181 (5.50")Passed (29%)--1.0 D + 0.75 L + 0.75 S (All Spans)
Shear (lbs)1642 @ 7'7902 Passed (21%)1.15 1.0 D + 0.75 L + 0.75 S (All Spans)
Moment (Ft-lbs)4018 @ 3' 10"11985 Passed (34%)1.15 1.0 D + 0.75 L + 0.75 S (All Spans)
Live Load Defl. (in)0.050 @ 4' 1 7/16"0.190 Passed (L/999+)--1.0 D + 0.75 L + 0.75 S (All Spans)
Total Load Defl. (in)0.126 @ 4' 1 7/16"0.379 Passed (L/720)--1.0 D + 0.75 L + 0.75 S (All Spans)
System : Floor
Member Type : Flush Beam
Building Use : Residential
Building Code : IBC 2018
Design Methodology : ASD
•Deflection criteria: LL (L/480) and TL (L/240).
•Allowed moment does not reflect the adjustment for the beam stability factor.
• Blocking Panels are assumed to carry no loads applied directly above them and the full load is applied to the member being designed.
Bearing Length Loads to Supports (lbs)
Supports Total Available Required Dead Floor Live Snow Total Accessories
1 - Stud wall - SPF 5.50"5.50"1.57"1409 495 734 2638 Blocking
2 - Stud wall - SPF 5.50"5.50"1.57"1414 495 736 2645 Blocking
•Maximum allowable bracing intervals based on applied load.
Lateral Bracing Bracing Intervals Comments
Top Edge (Lu)8' 3" o/c
Bottom Edge (Lu)8' 3" o/c
Dead Floor Live Snow
Vertical Loads Location (Side)Tributary Width (0.90)(1.00)(1.15)Comments
0 - Self Weight (PLF)0 to 8' 3"N/A 10.4 ----
1 - Uniform (PSF)0 to 8' 3" (Front)3'15.0 40.0 -Floor - Upper Level
2 - Uniform (PLF)0 to 8' 3" (Front)N/A 80.0 --Wall - Upper Level
3 - Uniform (PSF)0 to 8' 3" (Front)2'20.0 -35.0 Snow - Porch
4 - Uniform (PLF)0 to 3' 6" (Front)N/A 100.0 --Wall - Gable
5 - Uniform (PSF)0 to 3' 6" (Front)3'20.0 -35.0 Snow - Main
6 - Uniform (PLF)5' 6" to 8' 3" (Front)N/A 100.0 --Wall - Gable
7 - Uniform (PSF)5' 6" to 8' 3" (Front)3'20.0 -35.0 Snow - Main
8 - Point (lb)3' 6" (Front)N/A 188 -118
Linked from:
Bedroom 3 & 4
Bath Window,
Support 1
9 - Point (lb)5' 6" (Front)N/A 188 -118
Linked from:
Bedroom 3 & 4
Bath Window,
Support 2
All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal.
MEMBER REPORT PASSED
Main Level, Front Porch FLR Beam
2 piece(s) 1 3/4" x 9 1/2" 1.55E TimberStrand® LSL
ForteWEB Software Operator Job Notes 4/28/2021 8:33:07 PM UTCJeffrey Doty, Design Supervisor
Lyman Lumber Company
(952) 470-4866
jeff_doty@lymanlumber.com
ForteWEB v3.1, Engine: V8.1.6.2, Data: V8.0.1.0
File Name: 17870 Eclipse Ave, Lakeville, MN
Topaz - Connor
17870 Eclipse Ave, Lakeville, MN
4/28/21; #24806
Page 17 / 39
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties
related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is
responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387
and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to
www.weyerhaeuser.com/woodproducts/document-library.
The product application, input design loads, dimensions and support information have been provided by plan dated 3/30/21.
Weyerhaeuser Notes
ForteWEB Software Operator Job Notes 4/28/2021 8:33:07 PM UTCJeffrey Doty, Design Supervisor
Lyman Lumber Company
(952) 470-4866
jeff_doty@lymanlumber.com
ForteWEB v3.1, Engine: V8.1.6.2, Data: V8.0.1.0
File Name: 17870 Eclipse Ave, Lakeville, MN
Topaz - Connor
17870 Eclipse Ave, Lakeville, MN
4/28/21; #24806
Page 18 / 39
Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern)
Member Reaction (lbs)1678 @ 1 1/2"3825 (3.00")Passed (44%)--1.0 D + 1.0 S (All Spans)
Shear (lbs)1223 @ 1' 2 1/4"3493 Passed (35%)1.15 1.0 D + 1.0 S (All Spans)
Moment (Ft-lbs)3464 @ 4' 4 1/2"5306 Passed (65%)1.15 1.0 D + 1.0 S (All Spans)
Live Load Defl. (in)0.041 @ 4' 4 1/2"0.283 Passed (L/999+)--1.0 D + 1.0 S (All Spans)
Total Load Defl. (in)0.090 @ 4' 4 1/2"0.425 Passed (L/999+)--1.0 D + 1.0 S (All Spans)
System : Wall
Member Type : Header
Building Use : Residential
Building Code : IBC 2018
Design Methodology : ASD
•Deflection criteria: LL (L/360) and TL (L/240).
•Allowed moment does not reflect the adjustment for the beam stability factor.
•Applicable calculations are based on NDS.
Bearing Length Loads to Supports (lbs)
Supports Total Available Required Dead Snow Total Accessories
1 - Trimmer - SPF 3.00"3.00"1.50"912 766 1678 None
2 - Trimmer - SPF 3.00"3.00"1.50"912 766 1678 None
•Maximum allowable bracing intervals based on applied load.
Lateral Bracing Bracing Intervals Comments
Top Edge (Lu)8' 9" o/c
Bottom Edge (Lu)8' 9" o/c
Dead Snow
Vertical Loads Location (Side)Tributary Width (0.90)(1.15)Comments
0 - Self Weight (PLF)0 to 8' 9"N/A 8.6 --
1 - Uniform (PSF)0 to 8' 9"5'20.0 35.0 Snow - Garage
2 - Uniform (PLF)0 to 8' 9"N/A 100.0 -Wall - Gable
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties
related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is
responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387
and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to
www.weyerhaeuser.com/woodproducts/document-library.
The product application, input design loads, dimensions and support information have been provided by plan dated 3/30/21.
Weyerhaeuser Notes
All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal.
MEMBER REPORT PASSED
Main Level, Garage 8' OHD
2 piece(s) 2 x 12 Spruce-Pine-Fir No. 1 / No. 2
ForteWEB Software Operator Job Notes 4/28/2021 8:33:07 PM UTCJeffrey Doty, Design Supervisor
Lyman Lumber Company
(952) 470-4866
jeff_doty@lymanlumber.com
ForteWEB v3.1, Engine: V8.1.6.2, Data: V8.0.1.0
File Name: 17870 Eclipse Ave, Lakeville, MN
Topaz - Connor
17870 Eclipse Ave, Lakeville, MN
4/28/21; #24806
Page 19 / 39
Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern)
Member Reaction (lbs)16514 @ 16' 10 1/2"20672 (5.25")Passed (80%)--1.0 D + 1.0 S (All Spans)
Shear (lbs)14758 @ 14' 9"27531 Passed (54%)1.15 1.0 D + 0.75 L + 0.75 S (All Spans)
Moment (Ft-lbs)86727 @ 10' 9"114283 Passed (76%)1.15 1.0 D + 0.75 L + 0.75 S (All Spans)
Live Load Defl. (in)0.174 @ 9' 2 1/16"0.550 Passed (L/999+)--1.0 D + 0.75 L + 0.75 S (All Spans)
Total Load Defl. (in)0.354 @ 9' 2"0.825 Passed (L/559)--1.0 D + 0.75 L + 0.75 S (All Spans)
System : Wall
Member Type : Header
Building Use : Residential
Building Code : IBC 2018
Design Methodology : ASD
•Deflection criteria: LL (L/360) and TL (L/240).
•Allowed moment does not reflect the adjustment for the beam stability factor.
Bearing Length Loads to Supports (lbs)
Supports Total Available Required Dead Floor Live Snow Total Accessories
1 - Trimmer - SPF 6.00"6.00"2.54"4907 1475 4773 11155 None
2 - Trimmer - PSL 5.25"5.25"4.19"8213 2499 8301 19013 None
•Maximum allowable bracing intervals based on applied load.
Lateral Bracing Bracing Intervals Comments
Top Edge (Lu)5' o/c
Bottom Edge (Lu)17' 2" o/c
Dead Floor Live Snow
Vertical Loads Location (Side)Tributary Width (0.90)(1.00)(1.15)Comments
0 - Self Weight (PLF)0 to 17' 2 1/4"N/A 36.8 ----
1 - Uniform (PSF)0 to 10' 9"4'20.0 -35.0 roof
2 - Uniform (PSF)10' 9" to 17' 2 1/4"13'20.0 -35.0 roof
3 - Point (lb)10' 9"N/A 9954 3974 8640 Linked from: GT2,
Support 1
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties
related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is
responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387
and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to
www.weyerhaeuser.com/woodproducts/document-library.
The product application, input design loads, dimensions and support information have been provided by plan dated 3/30/21.
Weyerhaeuser Notes
All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal.
MEMBER REPORT PASSED
Main Level, Garage 16' OHD
3 piece(s) 1 3/4" x 24" 2.0E Microllam® LVL
ForteWEB Software Operator Job Notes 4/28/2021 8:33:07 PM UTCJeffrey Doty, Design Supervisor
Lyman Lumber Company
(952) 470-4866
jeff_doty@lymanlumber.com
ForteWEB v3.1, Engine: V8.1.6.2, Data: V8.0.1.0
File Name: 17870 Eclipse Ave, Lakeville, MN
Topaz - Connor
17870 Eclipse Ave, Lakeville, MN
4/28/21; #24806
Page 20 / 39
Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern)
Member Reaction (lbs)1516 @ 1 1/2"3825 (3.00")Passed (40%)--1.0 D + 1.0 L (All Spans)
Shear (lbs)1000 @ 1' 1/4"2498 Passed (40%)1.00 1.0 D + 1.0 L (All Spans)
Moment (Ft-lbs)2089 @ 3'3431 Passed (61%)1.00 1.0 D + 1.0 L (All Spans)
Live Load Defl. (in)0.032 @ 3'0.192 Passed (L/999+)--1.0 D + 1.0 L (All Spans)
Total Load Defl. (in)0.045 @ 3'0.287 Passed (L/999+)--1.0 D + 1.0 L (All Spans)
System : Wall
Member Type : Header
Building Use : Residential
Building Code : IBC 2018
Design Methodology : ASD
•Deflection criteria: LL (L/360) and TL (L/240).
•Allowed moment does not reflect the adjustment for the beam stability factor.
•Applicable calculations are based on NDS.
Bearing Length Loads to Supports (lbs)
Supports Total Available Required Dead Floor Live Total Accessories
1 - Trimmer - SPF 3.00"3.00"1.50"429 1088 1517 None
2 - Trimmer - SPF 3.00"3.00"1.50"429 1088 1517 None
•Maximum allowable bracing intervals based on applied load.
Lateral Bracing Bracing Intervals Comments
Top Edge (Lu)6' o/c
Bottom Edge (Lu)6' o/c
Dead Floor Live
Vertical Loads Location (Side)Tributary Width (0.90)(1.00)Comments
0 - Self Weight (PLF)0 to 6'N/A 7.0 --
1 - Uniform (PSF)0 to 6'9' 3/4"15.0 40.0 floor
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties
related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is
responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387
and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to
www.weyerhaeuser.com/woodproducts/document-library.
The product application, input design loads, dimensions and support information have been provided by plan dated 3/30/21.
Weyerhaeuser Notes
All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal.
MEMBER REPORT PASSED
Main Level, Front Door Hdr
2 piece(s) 2 x 10 Spruce-Pine-Fir No. 1 / No. 2
ForteWEB Software Operator Job Notes 4/28/2021 8:33:07 PM UTCJeffrey Doty, Design Supervisor
Lyman Lumber Company
(952) 470-4866
jeff_doty@lymanlumber.com
ForteWEB v3.1, Engine: V8.1.6.2, Data: V8.0.1.0
File Name: 17870 Eclipse Ave, Lakeville, MN
Topaz - Connor
17870 Eclipse Ave, Lakeville, MN
4/28/21; #24806
Page 21 / 39
Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern)
Member Reaction (lbs)2466 @ 1 1/2"3825 (3.00")Passed (64%)--1.0 D + 0.75 L + 0.75 S (All Spans)
Shear (lbs)1361 @ 1' 1/4"2498 Passed (54%)1.00 1.0 D + 1.0 L (All Spans)
Moment (Ft-lbs)2647 @ 3' 3"3431 Passed (77%)1.00 1.0 D + 1.0 L (All Spans)
Live Load Defl. (in)0.037 @ 3' 3"0.208 Passed (L/999+)--1.0 D + 0.75 L + 0.75 S (All Spans)
Total Load Defl. (in)0.076 @ 3' 3"0.313 Passed (L/993)--1.0 D + 0.75 L + 0.75 S (All Spans)
System : Wall
Member Type : Header
Building Use : Residential
Building Code : IBC 2018
Design Methodology : ASD
•Deflection criteria: LL (L/360) and TL (L/240).
•Allowed moment does not reflect the adjustment for the beam stability factor.
•Applicable calculations are based on NDS.
Bearing Length Loads to Supports (lbs)
Supports Total Available Required Dead Floor Live Snow Total Accessories
1 - Trimmer - SPF 3.00"3.00"1.93"1349 780 709 2838 None
2 - Trimmer - SPF 3.00"3.00"1.93"1349 780 709 2838 None
•Maximum allowable bracing intervals based on applied load.
Lateral Bracing Bracing Intervals Comments
Top Edge (Lu)6' 6" o/c
Bottom Edge (Lu)6' 6" o/c
Dead Floor Live Snow
Vertical Loads Location (Side)Tributary Width (0.90)(1.00)(1.15)Comments
0 - Self Weight (PLF)0 to 6' 6"N/A 7.0 ----
1 - Uniform (PSF)0 to 6' 6"6'15.0 40.0 -floor
2 - Uniform (PLF)0 to 6' 6"N/A 80.0 --wall
3 - Uniform (PLF)0 to 9"N/A 100.0 --gable
4 - Uniform (PSF)0 to 9"3'20.0 -35.0 roof
5 - Uniform (PSF)5' 9" to 6' 6"3'20.0 -35.0 roof
6 - Uniform (PLF)5' 9" to 6' 6"N/A 100.0 --gable
7 - Uniform (PSF)0 to 6' 6"3'20.0 -35.0 Snow - Porch
8 - Point (lb)9"N/A 459 -289
Linked from: Wdw
Hdr Bed #3,
Support 1
9 - Point (lb)5' 9"N/A 459 -289
Linked from: Wdw
Hdr Bed #3,
Support 2
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties
related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is
responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387
and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to
www.weyerhaeuser.com/woodproducts/document-library.
The product application, input design loads, dimensions and support information have been provided by plan dated 3/30/21.
Weyerhaeuser Notes
All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal.
MEMBER REPORT PASSED
Main Level, Office Window
2 piece(s) 2 x 10 Spruce-Pine-Fir No. 1 / No. 2
ForteWEB Software Operator Job Notes 4/28/2021 8:33:07 PM UTCJeffrey Doty, Design Supervisor
Lyman Lumber Company
(952) 470-4866
jeff_doty@lymanlumber.com
ForteWEB v3.1, Engine: V8.1.6.2, Data: V8.0.1.0
File Name: 17870 Eclipse Ave, Lakeville, MN
Topaz - Connor
17870 Eclipse Ave, Lakeville, MN
4/28/21; #24806
Page 22 / 39
Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern)
Member Reaction (lbs)4120 @ 5 1/2"4725 (1.50")Passed (87%)--1.0 D + 1.0 L (All Spans)
Shear (lbs)3182 @ 1' 5 3/8"8590 Passed (37%)1.00 1.0 D + 1.0 L (All Spans)
Moment (Ft-lbs)8954 @ 4' 9 11/16"15953 Passed (56%)1.00 1.0 D + 1.0 L (All Spans)
Live Load Defl. (in)0.137 @ 4' 9 5/16"0.216 Passed (L/756)--1.0 D + 1.0 L (All Spans)
Total Load Defl. (in)0.191 @ 4' 9 5/16"0.431 Passed (L/542)--1.0 D + 1.0 L (All Spans)
System : Floor
Member Type : Flush Beam
Building Use : Residential
Building Code : IBC 2018
Design Methodology : ASD
•Deflection criteria: LL (L/480) and TL (L/240).
•Allowed moment does not reflect the adjustment for the beam stability factor.
• Blocking Panels are assumed to carry no loads applied directly above them and the full load is applied to the member being designed.
• At hanger supports, the Total Bearing dimension is equal to the width of the material that is supporting the hanger
• ¹ See Connector grid below for additional information and/or requirements.
Bearing Length Loads to Supports (lbs)
Supports Total Available Required Dead Floor Live Total Accessories
1 - Hanger on 11 7/8" LSL beam 5.50"Hanger¹1.50"1281 3268 4549 See note ¹
2 - Beam - SPF 5.50"5.50"3.18"1334 3396 4730 Blocking
•Maximum allowable bracing intervals based on applied load.
Lateral Bracing Bracing Intervals Comments
Top Edge (Lu)9' o/c
Bottom Edge (Lu)9' o/c
Connector: Simpson Strong-Tie
Support Model Seat Length Top Fasteners Face Fasteners Member Fasteners Accessories
1 - Face Mount Hanger HHUS48 3.00"N/A 22-16d 8-16d
•Refer to manufacturer notes and instructions for proper installation and use of all connectors.
Dead Floor Live
Vertical Loads Location (Side)Tributary Width (0.90)(1.00)Comments
0 - Self Weight (PLF)5 1/2" to 9' 5"N/A 13.0 --
1 - Uniform (PSF)7' 3" to 9' 5" (Front)20'15.0 40.0 Floor - Upper Level
2 - Uniform (PSF)0 to 7' 3" (Front)17'15.0 40.0 Floor - Upper Level
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties
related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is
responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387
and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to
www.weyerhaeuser.com/woodproducts/document-library.
The product application, input design loads, dimensions and support information have been provided by plan dated 3/30/21.
Weyerhaeuser Notes
All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal.
MEMBER REPORT PASSED
Main Level, Flush Beam over Foyer (H)
2 piece(s) 1 3/4" x 11 7/8" 1.55E TimberStrand® LSL
ForteWEB Software Operator Job Notes 4/28/2021 8:33:07 PM UTCJeffrey Doty, Design Supervisor
Lyman Lumber Company
(952) 470-4866
jeff_doty@lymanlumber.com
ForteWEB v3.1, Engine: V8.1.6.2, Data: V8.0.1.0
File Name: 17870 Eclipse Ave, Lakeville, MN
Topaz - Connor
17870 Eclipse Ave, Lakeville, MN
4/28/21; #24806
Page 23 / 39
Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern)
Member Reaction (lbs)2897 @ 4"8181 (5.50")Passed (35%)--1.0 D + 1.0 L (All Spans)
Shear (lbs)2578 @ 1' 5 3/8"8590 Passed (30%)1.00 1.0 D + 1.0 L (All Spans)
Moment (Ft-lbs)5007 @ 2' 3"15953 Passed (31%)1.00 1.0 D + 1.0 L (All Spans)
Live Load Defl. (in)0.024 @ 2' 3"0.101 Passed (L/999+)--1.0 D + 1.0 L (All Spans)
Total Load Defl. (in)0.034 @ 2' 3"0.201 Passed (L/999+)--1.0 D + 1.0 L (All Spans)
System : Floor
Member Type : Flush Beam
Building Use : Residential
Building Code : IBC 2018
Design Methodology : ASD
•Deflection criteria: LL (L/480) and TL (L/240).
•Allowed moment does not reflect the adjustment for the beam stability factor.
• Blocking Panels are assumed to carry no loads applied directly above them and the full load is applied to the member being designed.
Bearing Length Loads to Supports (lbs)
Supports Total Available Required Dead Floor Live Snow Total Accessories
1 - Stud wall - SPF 5.50"5.50"1.95"859 2038 82 2979 Blocking
2 - Stud wall - SPF 5.50"5.50"1.81"799 1886 82 2767 Blocking
•Maximum allowable bracing intervals based on applied load.
Lateral Bracing Bracing Intervals Comments
Top Edge (Lu)4' 8" o/c
Bottom Edge (Lu)4' 8" o/c
Dead Floor Live Snow
Vertical Loads Location (Side)Tributary Width (0.90)(1.00)(1.15)Comments
0 - Self Weight (PLF)0 to 4' 8 1/4"N/A 13.0 ----
1 - Uniform (PSF)0 to 4' 8 1/4" (Front)3' 6"15.0 40.0 -stairs
2 - Uniform (PSF)0 to 4' 8 1/4" (Front)1'15.0 -35.0 floor
3 - Point (lb)2' 3" (Front)N/A 1281 3268 -
Linked from: Flush
Beam Foyer,
Support 1
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties
related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is
responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387
and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to
www.weyerhaeuser.com/woodproducts/document-library.
The product application, input design loads, dimensions and support information have been provided by plan dated 3/30/21.
Weyerhaeuser Notes
All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal.
MEMBER REPORT PASSED
Main Level, Flush Beam Stairway down
2 piece(s) 1 3/4" x 11 7/8" 1.55E TimberStrand® LSL
ForteWEB Software Operator Job Notes 4/28/2021 8:33:07 PM UTCJeffrey Doty, Design Supervisor
Lyman Lumber Company
(952) 470-4866
jeff_doty@lymanlumber.com
ForteWEB v3.1, Engine: V8.1.6.2, Data: V8.0.1.0
File Name: 17870 Eclipse Ave, Lakeville, MN
Topaz - Connor
17870 Eclipse Ave, Lakeville, MN
4/28/21; #24806
Page 24 / 39
Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern)
Member Reaction (lbs)2227 @ 0 2869 (1.50")Passed (78%)--1.0 D + 1.0 S (All Spans)
Shear (lbs)999 @ 10 3/4"4308 Passed (23%)1.15 1.0 D + 1.0 S (All Spans)
Moment (Ft-lbs)1810 @ 1' 7 1/2"5919 Passed (31%)1.15 1.0 D + 1.0 S (All Spans)
Live Load Defl. (in)0.005 @ 1' 7 1/2"0.108 Passed (L/999+)--1.0 D + 1.0 S (All Spans)
Total Load Defl. (in)0.008 @ 1' 7 1/2"0.162 Passed (L/999+)--1.0 D + 1.0 S (All Spans)
System : Wall
Member Type : Header
Building Use : Residential
Building Code : IBC 2018
Design Methodology : ASD
•Deflection criteria: LL (L/360) and TL (L/240).
•Allowed moment does not reflect the adjustment for the beam stability factor.
•Applicable calculations are based on NDS.
Bearing Length Loads to Supports (lbs)
Supports Total Available Required Dead Floor Live Snow Total Accessories
1 - Trimmer - SPF 1.50"1.50"1.50"919 65 1308 2292 None
2 - Trimmer - SPF 1.50"1.50"1.50"919 65 1308 2292 None
•Maximum allowable bracing intervals based on applied load.
Lateral Bracing Bracing Intervals Comments
Top Edge (Lu)3' 3" o/c
Bottom Edge (Lu)3' 3" o/c
Dead Floor Live Snow
Vertical Loads Location (Side)Tributary Width (0.90)(1.00)(1.15)Comments
0 - Self Weight (PLF)0 to 3' 3"N/A 10.6 ----
1 - Uniform (PSF)0 to 3' 3"1'15.0 40.0 -floor
2 - Uniform (PLF)0 to 3' 3"N/A 80.0 --wall
3 - Uniform (PSF)0 to 3' 3"23'20.0 -35.0 roof
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties
related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is
responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387
and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to
www.weyerhaeuser.com/woodproducts/document-library.
The product application, input design loads, dimensions and support information have been provided by plan dated 3/30/21.
Weyerhaeuser Notes
All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal.
MEMBER REPORT PASSED
Main Level, Great Room Side Window
3 piece(s) 2 x 10 Spruce-Pine-Fir No. 1 / No. 2
ForteWEB Software Operator Job Notes 4/28/2021 8:33:07 PM UTCJeffrey Doty, Design Supervisor
Lyman Lumber Company
(952) 470-4866
jeff_doty@lymanlumber.com
ForteWEB v3.1, Engine: V8.1.6.2, Data: V8.0.1.0
File Name: 17870 Eclipse Ave, Lakeville, MN
Topaz - Connor
17870 Eclipse Ave, Lakeville, MN
4/28/21; #24806
Page 25 / 39
Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern)
Member Reaction (lbs)5936 @ 4"20934 (5.50")Passed (28%)--1.0 D + 1.0 L (All Spans)
Shear (lbs)4650 @ 1' 7 1/2"13965 Passed (33%)1.00 1.0 D + 1.0 L (All Spans)
Moment (Ft-lbs)20325 @ 7' 6"36387 Passed (56%)1.00 1.0 D + 1.0 L (All Spans)
Live Load Defl. (in)0.244 @ 7' 6"0.358 Passed (L/705)--1.0 D + 1.0 L (All Spans)
Total Load Defl. (in)0.345 @ 7' 6"0.717 Passed (L/499)--1.0 D + 1.0 L (All Spans)
System : Floor
Member Type : Flush Beam
Building Use : Residential
Building Code : IBC 2018
Design Methodology : ASD
•Deflection criteria: LL (L/480) and TL (L/240).
•Allowed moment does not reflect the adjustment for the beam stability factor.
• Blocking Panels are assumed to carry no loads applied directly above them and the full load is applied to the member being designed.
Bearing Length Loads to Supports (lbs)
Supports Total Available Required Dead Floor Live Total Accessories
1 - Column - SPF 5.50"5.50"1.56"1736 4200 5936 Blocking
2 - Column - SPF 5.50"5.50"1.56"1736 4200 5936 Blocking
•Maximum allowable bracing intervals based on applied load.
Lateral Bracing Bracing Intervals Comments
Top Edge (Lu)15' o/c
Bottom Edge (Lu)15' o/c
Dead Floor Live
Vertical Loads Location (Side)Tributary Width (0.90)(1.00)Comments
0 - Self Weight (PLF)0 to 15'N/A 21.5 --
1 - Uniform (PSF)0 to 15' (Front)14'15.0 40.0 floor
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties
related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is
responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387
and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to
www.weyerhaeuser.com/woodproducts/document-library.
The product application, input design loads, dimensions and support information have been provided by plan dated 3/30/21.
Weyerhaeuser Notes
All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal.
MEMBER REPORT PASSED
Main Level, Dining Room Flush Beam
3 piece(s) 1 3/4" x 14" 2.0E Microllam® LVL
ForteWEB Software Operator Job Notes 4/28/2021 8:33:07 PM UTCJeffrey Doty, Design Supervisor
Lyman Lumber Company
(952) 470-4866
jeff_doty@lymanlumber.com
ForteWEB v3.1, Engine: V8.1.6.2, Data: V8.0.1.0
File Name: 17870 Eclipse Ave, Lakeville, MN
Topaz - Connor
17870 Eclipse Ave, Lakeville, MN
4/28/21; #24806
Page 26 / 39
Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern)
Member Reaction (lbs)40 @ 0 1913 (1.50")Passed (2%)--1.0 D (All Spans)
Shear (lbs)23 @ 10 3/4"2248 Passed (1%)0.90 1.0 D (All Spans)
Moment (Ft-lbs)43 @ 2' 1 1/2"3088 Passed (1%)0.90 1.0 D (All Spans)
Live Load Defl. (in)0.000 @ 0 0.142 Passed (2L/999+)--1.0 D (All Spans)
Total Load Defl. (in)0.001 @ 2' 1 1/2"0.213 Passed (L/999+)--1.0 D (All Spans)
System : Wall
Member Type : Header
Building Use : Residential
Building Code : IBC 2018
Design Methodology : ASD
•Deflection criteria: LL (L/360) and TL (L/240).
•Allowed moment does not reflect the adjustment for the beam stability factor.
•Applicable calculations are based on NDS.
Bearing Length Loads to Supports
(lbs)
Supports Total Available Required Dead Total Accessories
1 - Trimmer - SPF 1.50"1.50"1.50"40 40 None
2 - Trimmer - SPF 1.50"1.50"1.50"40 40 None
•Maximum allowable bracing intervals based on applied load.
Lateral Bracing Bracing Intervals Comments
Top Edge (Lu)4' 3" o/c
Bottom Edge (Lu)4' 3" o/c
Dead
Vertical Loads Location (Side)Tributary Width (0.90)Comments
0 - Self Weight (PLF)0 to 4' 3"N/A 7.0
1 - Uniform (PLF)0 to 4' 3"N/A 12.0 Wall - Upper Level
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties
related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is
responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387
and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to
www.weyerhaeuser.com/woodproducts/document-library.
The product application, input design loads, dimensions and support information have been provided by plan dated 3/30/21.
Weyerhaeuser Notes
All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal.
MEMBER REPORT PASSED
Main Level, Stair Landing Window
2 piece(s) 2 x 10 Spruce-Pine-Fir No. 1 / No. 2
ForteWEB Software Operator Job Notes 4/28/2021 8:33:07 PM UTCJeffrey Doty, Design Supervisor
Lyman Lumber Company
(952) 470-4866
jeff_doty@lymanlumber.com
ForteWEB v3.1, Engine: V8.1.6.2, Data: V8.0.1.0
File Name: 17870 Eclipse Ave, Lakeville, MN
Topaz - Connor
17870 Eclipse Ave, Lakeville, MN
4/28/21; #24806
Page 27 / 39
Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern)
Member Reaction (lbs)1456 @ 0 1913 (1.50")Passed (76%)--1.0 D + 1.0 L (All Spans)
Shear (lbs)692 @ 10 3/4"2498 Passed (28%)1.00 1.0 D + 1.0 L (All Spans)
Moment (Ft-lbs)1243 @ 1' 8 1/2"3431 Passed (36%)1.00 1.0 D + 1.0 L (All Spans)
Live Load Defl. (in)0.005 @ 1' 8 1/2"0.114 Passed (L/999+)--1.0 D + 1.0 L (All Spans)
Total Load Defl. (in)0.009 @ 1' 8 1/2"0.171 Passed (L/999+)--1.0 D + 1.0 L (All Spans)
System : Wall
Member Type : Header
Building Use : Residential
Building Code : IBC 2018
Design Methodology : ASD
•Deflection criteria: LL (L/360) and TL (L/240).
•Allowed moment does not reflect the adjustment for the beam stability factor.
•Applicable calculations are based on NDS.
Bearing Length Loads to Supports (lbs)
Supports Total Available Required Dead Floor Live Snow Total Accessories
1 - Trimmer - SPF 1.50"1.50"1.50"704 752 179 1635 None
2 - Trimmer - SPF 1.50"1.50"1.50"704 752 179 1635 None
•Maximum allowable bracing intervals based on applied load.
Lateral Bracing Bracing Intervals Comments
Top Edge (Lu)3' 5" o/c
Bottom Edge (Lu)3' 5" o/c
Dead Floor Live Snow
Vertical Loads Location (Side)Tributary Width (0.90)(1.00)(1.15)Comments
0 - Self Weight (PLF)0 to 3' 5"N/A 7.0 ----
1 - Uniform (PSF)0 to 3' 5"11'15.0 40.0 -Floor - Upper Level
2 - Uniform (PSF)0 to 3' 5"1'80.0 --Wall - Upper Level
3 - Uniform (PSF)0 to 3' 5"1'100.0 --Wall - Gable
4 - Uniform (PSF)0 to 3' 5"3'20.0 -35.0 Snow - Main
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties
related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is
responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387
and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to
www.weyerhaeuser.com/woodproducts/document-library.
The product application, input design loads, dimensions and support information have been provided by plan dated 3/30/21.
Weyerhaeuser Notes
All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal.
MEMBER REPORT PASSED
Main Level, Dining Room Hall Door
2 piece(s) 2 x 10 Spruce-Pine-Fir No. 1 / No. 2
ForteWEB Software Operator Job Notes 4/28/2021 8:33:07 PM UTCJeffrey Doty, Design Supervisor
Lyman Lumber Company
(952) 470-4866
jeff_doty@lymanlumber.com
ForteWEB v3.1, Engine: V8.1.6.2, Data: V8.0.1.0
File Name: 17870 Eclipse Ave, Lakeville, MN
Topaz - Connor
17870 Eclipse Ave, Lakeville, MN
4/28/21; #24806
Page 28 / 39
Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern)
Member Reaction (lbs)1248 @ 2"4463 (3.50")Passed (28%)--1.0 D + 1.0 L (All Spans)
Shear (lbs)773 @ 1' 3/4"2498 Passed (31%)1.00 1.0 D + 1.0 L (All Spans)
Moment (Ft-lbs)1540 @ 2' 9 1/2"3431 Passed (45%)1.00 1.0 D + 1.0 L (All Spans)
Live Load Defl. (in)0.020 @ 2' 9 1/2"0.131 Passed (L/999+)--1.0 D + 1.0 L (All Spans)
Total Load Defl. (in)0.028 @ 2' 9 1/2"0.262 Passed (L/999+)--1.0 D + 1.0 L (All Spans)
System : Floor
Member Type : Flush Beam
Building Use : Residential
Building Code : IBC 2018
Design Methodology : ASD
•Deflection criteria: LL (L/480) and TL (L/240).
•Allowed moment does not reflect the adjustment for the beam stability factor.
•Applicable calculations are based on NDS.
• Blocking Panels are assumed to carry no loads applied directly above them and the full load is applied to the member being designed.
Bearing Length Loads to Supports (lbs)
Supports Total Available Required Dead Floor Live Total Accessories
1 - Stud wall - SPF 3.50"3.50"1.50"355 893 1248 Blocking
2 - Stud wall - SPF 3.50"3.50"1.50"355 893 1248 Blocking
•Maximum allowable bracing intervals based on applied load.
Lateral Bracing Bracing Intervals Comments
Top Edge (Lu)5' 7" o/c
Bottom Edge (Lu)5' 7" o/c
Dead Floor Live
Vertical Loads Location (Side)Tributary Width (0.90)(1.00)Comments
0 - Self Weight (PLF)0 to 5' 7"N/A 7.0 --
1 - Uniform (PSF)0 to 5' 7" (Front)8'15.0 40.0 Floor - Upper Level
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties
related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is
responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387
and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to
www.weyerhaeuser.com/woodproducts/document-library.
The product application, input design loads, dimensions and support information have been provided by plan dated 3/30/21.
Weyerhaeuser Notes
All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal.
MEMBER REPORT PASSED
Main Level, Stairs Flush Beam
2 piece(s) 2 x 10 Spruce-Pine-Fir No. 1 / No. 2
ForteWEB Software Operator Job Notes 4/28/2021 8:33:07 PM UTCJeffrey Doty, Design Supervisor
Lyman Lumber Company
(952) 470-4866
jeff_doty@lymanlumber.com
ForteWEB v3.1, Engine: V8.1.6.2, Data: V8.0.1.0
File Name: 17870 Eclipse Ave, Lakeville, MN
Topaz - Connor
17870 Eclipse Ave, Lakeville, MN
4/28/21; #24806
Page 29 / 39
Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern)
Member Reaction (lbs)2697 @ 0 2869 (1.50")Passed (94%)--1.0 D + 1.0 S (All Spans)
Shear (lbs)1581 @ 1' 4 1/4"4308 Passed (37%)1.15 1.0 D + 1.0 S (All Spans)
Moment (Ft-lbs)2012 @ 1'5919 Passed (34%)1.15 1.0 D + 1.0 S (All Spans)
Live Load Defl. (in)0.002 @ 1' 1 1/8"0.075 Passed (L/999+)--1.0 D + 1.0 S (All Spans)
Total Load Defl. (in)0.004 @ 1' 1 3/16"0.112 Passed (L/999+)--1.0 D + 1.0 S (All Spans)
System : Wall
Member Type : Header
Building Use : Residential
Building Code : IBC 2018
Design Methodology : ASD
•Deflection criteria: LL (L/360) and TL (L/240).
•Allowed moment does not reflect the adjustment for the beam stability factor.
•Applicable calculations are based on NDS.
Bearing Length Loads to Supports (lbs)
Supports Total Available Required Dead Floor Live Snow Total Accessories
1 - Trimmer - SPF 1.50"1.50"1.50"1065 45 1632 2742 None
2 - Trimmer - SPF 1.50"1.50"1.50"692 45 984 1721 None
•Maximum allowable bracing intervals based on applied load.
Lateral Bracing Bracing Intervals Comments
Top Edge (Lu)2' 3" o/c
Bottom Edge (Lu)2' 3" o/c
Dead Floor Live Snow
Vertical Loads Location (Side)Tributary Width (0.90)(1.00)(1.15)Comments
0 - Self Weight (PLF)0 to 2' 3"N/A 10.6 ----
1 - Uniform (PSF)0 to 2' 3"1'15.0 40.0 -Floor - Upper Level
2 - Uniform (PSF)0 to 2' 3"1'80.0 --Wall - Upper Level
3 - Uniform (PSF)0 to 1'23'20.0 -35.0 Snow - Main
4 - Point (lb)1'N/A 1059 -1811
Linked from:
Owner's Bathroom
Window, Support 1
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties
related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is
responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387
and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to
www.weyerhaeuser.com/woodproducts/document-library.
The product application, input design loads, dimensions and support information have been provided by plan dated 3/30/21.
Weyerhaeuser Notes
All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal.
MEMBER REPORT PASSED
Main Level, Mudroom Window
3 piece(s) 2 x 10 Spruce-Pine-Fir No. 1 / No. 2
ForteWEB Software Operator Job Notes 4/28/2021 8:33:07 PM UTCJeffrey Doty, Design Supervisor
Lyman Lumber Company
(952) 470-4866
jeff_doty@lymanlumber.com
ForteWEB v3.1, Engine: V8.1.6.2, Data: V8.0.1.0
File Name: 17870 Eclipse Ave, Lakeville, MN
Topaz - Connor
17870 Eclipse Ave, Lakeville, MN
4/28/21; #24806
Page 30 / 39
Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern)
Member Reaction (lbs)17829 @ 4"27913 (5.50")Passed (64%)--1.0 D + 1.0 S (All Spans)
Shear (lbs)14385 @ 2' 1 1/2"30590 Passed (47%)1.15 1.0 D + 1.0 S (All Spans)
Moment (Ft-lbs)92207 @ 11'108474 Passed (85%)1.15 1.0 D + 1.0 S (All Spans)
Live Load Defl. (in)0.516 @ 11'0.533 Passed (L/496)--1.0 D + 1.0 S (All Spans)
Total Load Defl. (in)0.885 @ 11'1.067 Passed (L/289)--1.0 D + 1.0 S (All Spans)
System : Floor
Member Type : Flush Beam
Building Use : Residential
Building Code : IBC 2018
Design Methodology : ASD
•Deflection criteria: LL (L/480) and TL (L/240).
•Allowed moment does not reflect the adjustment for the beam stability factor.
•Member should be side-loaded from both sides of the member or braced to prevent rotation.
Bearing Length Loads to Supports (lbs)
Supports Total Available Required Dead Floor Live Snow Total Accessories
1 - Trimmer - SPF 5.50"5.50"3.51"7434 440 10395 18269 None
2 - Trimmer - SPF 5.50"5.50"3.51"7434 440 10395 18269 None
•Maximum allowable bracing intervals based on applied load.
Lateral Bracing Bracing Intervals Comments
Top Edge (Lu)5' 10" o/c
Bottom Edge (Lu)22' o/c
Dead Floor Live Snow
Vertical Loads Location (Side)Tributary Width (0.90)(1.00)(1.15)Comments
0 - Self Weight (PLF)0 to 22'N/A 40.8 ----
1 - Uniform (PSF)0 to 22' (Front)1'15.0 40.0 -Floor - Upper Level
2 - Uniform (PLF)0 to 22' (Front)N/A 80.0 --Wall - Upper Level
3 - Uniform (PSF)0 to 22' (Front)23'20.0 -35.0 Snow - Main
4 - Uniform (PSF)0 to 22' (Front)4'20.0 -35.0 Snow - Lower
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties
related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is
responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387
and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to
www.weyerhaeuser.com/woodproducts/document-library.
The product application, input design loads, dimensions and support information have been provided by plan dated 3/30/21.
Weyerhaeuser Notes
All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal.
MEMBER REPORT PASSED
Main Level, Flush Flex (V)
4 piece(s) 1 3/4" x 20" 2.0E Microllam® LVL
ForteWEB Software Operator Job Notes 4/28/2021 8:33:07 PM UTCJeffrey Doty, Design Supervisor
Lyman Lumber Company
(952) 470-4866
jeff_doty@lymanlumber.com
ForteWEB v3.1, Engine: V8.1.6.2, Data: V8.0.1.0
File Name: 17870 Eclipse Ave, Lakeville, MN
Topaz - Connor
17870 Eclipse Ave, Lakeville, MN
4/28/21; #24806
Page 31 / 39
Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern)
Member Reaction (lbs)18816 @ 5 1/2"22050 (7.00")Passed (85%)--1.0 D + 1.0 S (All Spans)
Shear (lbs)608 @ 1' 4 1/2"7902 Passed (8%)1.15 1.0 D + 1.0 S (All Spans)
Moment (Ft-lbs)1345 @ 3' 7"11985 Passed (11%)1.15 1.0 D + 1.0 S (All Spans)
Live Load Defl. (in)0.012 @ 3' 7"0.208 Passed (L/999+)--1.0 D + 1.0 S (All Spans)
Total Load Defl. (in)0.030 @ 3' 7"0.313 Passed (L/999+)--1.0 D + 1.0 S (All Spans)
System : Wall
Member Type : Header
Building Use : Residential
Building Code : IBC 2018
Design Methodology : ASD
•Deflection criteria: LL (L/360) and TL (L/240).
•Allowed moment does not reflect the adjustment for the beam stability factor.
Bearing Length Loads to Supports (lbs)
Supports Total Available Required Dead Floor Live Snow Total Accessories
1 - Trimmer - PSL 7.00"7.00"5.97"8045 440 10771 19256 None
2 - Trimmer - SPF 3.00"3.00"1.50"554 -341 895 None
•Maximum allowable bracing intervals based on applied load.
Lateral Bracing Bracing Intervals Comments
Top Edge (Lu)6' 10" o/c
Bottom Edge (Lu)6' 10" o/c
Dead Floor Live Snow
Vertical Loads Location (Side)Tributary Width (0.90)(1.00)(1.15)Comments
0 - Self Weight (PLF)0 to 6' 10"N/A 10.4 ----
1 - Uniform (PSF)0 to 6' 10"3'20.0 -35.0 Snow - Lower
2 - Uniform (PLF)0 to 6' 10"N/A 100.0 --Wall - Gable
3 - Point (lb)0 N/A 7434 440 10395 Linked from: Flush
Flex (V), Support 2
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties
related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is
responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387
and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to
www.weyerhaeuser.com/woodproducts/document-library.
The product application, input design loads, dimensions and support information have been provided by plan dated 3/30/21.
Weyerhaeuser Notes
All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal.
MEMBER REPORT PASSED
Main Level, Flex Window Rear
2 piece(s) 1 3/4" x 9 1/2" 1.55E TimberStrand® LSL
ForteWEB Software Operator Job Notes 4/28/2021 8:33:07 PM UTCJeffrey Doty, Design Supervisor
Lyman Lumber Company
(952) 470-4866
jeff_doty@lymanlumber.com
ForteWEB v3.1, Engine: V8.1.6.2, Data: V8.0.1.0
File Name: 17870 Eclipse Ave, Lakeville, MN
Topaz - Connor
17870 Eclipse Ave, Lakeville, MN
4/28/21; #24806
Page 32 / 39
Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern)
Member Reaction (lbs)865 @ 3"1913 (1.50")Passed (45%)--1.0 D + 1.0 S (All Spans)
Shear (lbs)711 @ 1' 1/4"2872 Passed (25%)1.15 1.0 D + 1.0 S (All Spans)
Moment (Ft-lbs)1873 @ 4' 7"3946 Passed (47%)1.15 1.0 D + 1.0 S (All Spans)
Live Load Defl. (in)0.056 @ 4' 7"0.433 Passed (L/999+)--1.0 D + 1.0 S (All Spans)
Total Load Defl. (in)0.091 @ 4' 7"0.578 Passed (L/999+)--1.0 D + 1.0 S (All Spans)
System : Roof
Member Type : Drop Beam
Building Use : Residential
Building Code : IBC 2018
Design Methodology : ASD
Member Pitch : 0/12
•Deflection criteria: LL (L/240) and TL (L/180).
•Allowed moment does not reflect the adjustment for the beam stability factor.
•Applicable calculations are based on NDS.
• Blocking Panels are assumed to carry no loads applied directly above them and the full load is applied to the member being designed.
• At hanger supports, the Total Bearing dimension is equal to the width of the material that is supporting the hanger
• ¹ See Connector grid below for additional information and/or requirements.
Bearing Length Loads to Supports (lbs)
Supports Total Available Required Dead Snow Total Accessories
1 - Hanger on 9 1/4" SPF beam 3.00"Hanger¹1.50"351 561 912 See note ¹
2 - Stud wall - SPF 5.50"5.50"1.50"359 572 931 Blocking
•Maximum allowable bracing intervals based on applied load.
Lateral Bracing Bracing Intervals Comments
Top Edge (Lu)9' o/c
Bottom Edge (Lu)9' o/c
Connector: Simpson Strong-Tie
Support Model Seat Length Top Fasteners Face Fasteners Member Fasteners Accessories
1 - Face Mount Hanger LUS28-2 2.00"N/A 6-10dx1.5 4-10d
•Refer to manufacturer notes and instructions for proper installation and use of all connectors.
Dead Snow
Vertical Loads Location (Side)Tributary Width (0.90)(1.15)Comments
0 - Self Weight (PLF)3" to 9' 3"N/A 7.0 --
1 - Uniform (PSF)0 to 9' 3" (Front)3' 6"20.0 35.0 Snow - Porch
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties
related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is
responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387
and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to
www.weyerhaeuser.com/woodproducts/document-library.
The product application, input design loads, dimensions and support information have been provided by plan dated 3/30/21.
Weyerhaeuser Notes
All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal.
MEMBER REPORT PASSED
Main Level, Drop Front Porch (H)
2 piece(s) 2 x 10 Spruce-Pine-Fir No. 1 / No. 2
ForteWEB Software Operator Job Notes 4/28/2021 8:33:07 PM UTCJeffrey Doty, Design Supervisor
Lyman Lumber Company
(952) 470-4866
jeff_doty@lymanlumber.com
ForteWEB v3.1, Engine: V8.1.6.2, Data: V8.0.1.0
File Name: 17870 Eclipse Ave, Lakeville, MN
Topaz - Connor
17870 Eclipse Ave, Lakeville, MN
4/28/21; #24806
Page 33 / 39
Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern)
Member Reaction (lbs)2739 @ 1' 2 3/4"7013 (5.50")Passed (39%)--1.0 D + 1.0 S (All Spans)
Shear (lbs)830 @ 2' 2 3/4"2872 Passed (29%)1.15 1.0 D + 1.0 S (All Spans)
Moment (Ft-lbs)1538 @ 4' 1/2"3946 Passed (39%)1.15 1.0 D + 1.0 S (Alt Spans)
Live Load Defl. (in)0.019 @ 3' 11 11/16"0.272 Passed (L/999+)--1.0 D + 1.0 S (Alt Spans)
Total Load Defl. (in)0.029 @ 3' 11 13/16"0.363 Passed (L/999+)--1.0 D + 1.0 S (Alt Spans)
System : Roof
Member Type : Drop Beam
Building Use : Residential
Building Code : IBC 2018
Design Methodology : ASD
Member Pitch : 0/12
•Deflection criteria: LL (L/240) and TL (L/180).
•Overhang deflection criteria: LL (2L/240) and TL (2L/180).
•Allowed moment does not reflect the adjustment for the beam stability factor.
•Applicable calculations are based on NDS.
• Blocking Panels are assumed to carry no loads applied directly above them and the full load is applied to the member being designed.
Bearing Length Loads to Supports (lbs)
Supports Total Available Required Dead Snow Total Accessories
1 - Stud wall - SPF 5.50"5.50"2.15"1034 1705 2739 Blocking
2 - Stud wall - SPF 5.50"5.50"1.50"487 835 1322 Blocking
•Maximum allowable bracing intervals based on applied load.
Lateral Bracing Bracing Intervals Comments
Top Edge (Lu)7' o/c
Bottom Edge (Lu)7' o/c
Dead Snow
Vertical Loads Location (Side)Tributary Width (0.90)(1.15)Comments
0 - Self Weight (PLF)0 to 7'N/A 7.0 --
1 - Uniform (PSF)0 to 7' (Front)8'20.0 35.0 Snow - Porch
2 - Point (lb)1' (Front)N/A 351 561
Linked from: Drop
Front Porch (H),
Support 1
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties
related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is
responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387
and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to
www.weyerhaeuser.com/woodproducts/document-library.
The product application, input design loads, dimensions and support information have been provided by plan dated 3/30/21.
Weyerhaeuser Notes
All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal.
MEMBER REPORT PASSED
Main Level, Drop Front Porch (V)
2 piece(s) 2 x 10 Spruce-Pine-Fir No. 1 / No. 2
ForteWEB Software Operator Job Notes 4/28/2021 8:33:07 PM UTCJeffrey Doty, Design Supervisor
Lyman Lumber Company
(952) 470-4866
jeff_doty@lymanlumber.com
ForteWEB v3.1, Engine: V8.1.6.2, Data: V8.0.1.0
File Name: 17870 Eclipse Ave, Lakeville, MN
Topaz - Connor
17870 Eclipse Ave, Lakeville, MN
4/28/21; #24806
Page 34 / 39
Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern)
Member Reaction (lbs)11872 @ 4"12272 (5.50")Passed (97%)--1.0 D + 1.0 L (All Spans)
Shear (lbs)4650 @ 1' 7 1/2"13965 Passed (33%)1.00 1.0 D + 1.0 L (All Spans)
Moment (Ft-lbs)20325 @ 7' 6"36387 Passed (56%)1.00 1.0 D + 1.0 L (All Spans)
Live Load Defl. (in)0.244 @ 7' 6"0.358 Passed (L/705)--1.0 D + 1.0 L (All Spans)
Total Load Defl. (in)0.345 @ 7' 6"0.717 Passed (L/499)--1.0 D + 1.0 L (All Spans)
System : Floor
Member Type : Flush Beam
Building Use : Residential
Building Code : IBC 2018
Design Methodology : ASD
•Deflection criteria: LL (L/480) and TL (L/240).
•Allowed moment does not reflect the adjustment for the beam stability factor.
• Blocking Panels are assumed to carry no loads applied directly above them and the full load is applied to the member being designed.
Bearing Length Loads to Supports (lbs)
Supports Total Available Required Dead Floor Live Total Accessories
1 - Stud wall - SPF 5.50"5.50"5.32"3472 8400 11872 Blocking
2 - Stud wall - SPF 5.50"5.50"5.32"3472 8400 11872 Blocking
•Maximum allowable bracing intervals based on applied load.
Lateral Bracing Bracing Intervals Comments
Top Edge (Lu)15' o/c
Bottom Edge (Lu)15' o/c
Dead Floor Live
Vertical Loads Location (Side)Tributary Width (0.90)(1.00)Comments
0 - Self Weight (PLF)0 to 15'N/A 21.5 --
1 - Uniform (PSF)0 to 15' (Front)14'15.0 40.0 floor
2 - Point (lb)0 (Front)N/A 1736 4200
Linked from: Flush
Beam Dining,
Support 1
3 - Point (lb)15' (Front)N/A 1736 4200
Linked from: Flush
Beam Dining,
Support 2
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties
related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is
responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387
and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to
www.weyerhaeuser.com/woodproducts/document-library.
The product application, input design loads, dimensions and support information have been provided by plan dated 3/30/21.
Weyerhaeuser Notes
All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal.
MEMBER REPORT PASSED
Lower Level, Family Room Flush Beam
3 piece(s) 1 3/4" x 14" 2.0E Microllam® LVL
ForteWEB Software Operator Job Notes 4/28/2021 8:33:07 PM UTCJeffrey Doty, Design Supervisor
Lyman Lumber Company
(952) 470-4866
jeff_doty@lymanlumber.com
ForteWEB v3.1, Engine: V8.1.6.2, Data: V8.0.1.0
File Name: 17870 Eclipse Ave, Lakeville, MN
Topaz - Connor
17870 Eclipse Ave, Lakeville, MN
4/28/21; #24806
Page 35 / 39
Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern)
Member Reaction (lbs)19878 @ 5 1/2"26644 (7.00")Passed (75%)--1.0 D + 1.0 S (All Spans)
Shear (lbs)1835 @ 1' 4 1/2"10308 Passed (18%)1.00 1.0 D + 1.0 L (All Spans)
Moment (Ft-lbs)3701 @ 3' 1"15633 Passed (24%)1.00 1.0 D + 1.0 L (All Spans)
Live Load Defl. (in)0.029 @ 3' 1"0.175 Passed (L/999+)--1.0 D + 1.0 L (All Spans)
Total Load Defl. (in)0.043 @ 3' 1"0.262 Passed (L/999+)--1.0 D + 1.0 L (All Spans)
System : Wall
Member Type : Header
Building Use : Residential
Building Code : IBC 2018
Design Methodology : ASD
•Deflection criteria: LL (L/360) and TL (L/240).
•Allowed moment does not reflect the adjustment for the beam stability factor.
Bearing Length Loads to Supports (lbs)
Supports Total Available Required Dead Floor Live Snow Total Accessories
1 - Trimmer - SPF 7.00"7.00"5.22"9107 2691 10771 22569 None
2 - Trimmer - SPF 3.00"3.00"1.50"947 2008 -2955 None
•Maximum allowable bracing intervals based on applied load.
Lateral Bracing Bracing Intervals Comments
Top Edge (Lu)5' 10" o/c
Bottom Edge (Lu)5' 10" o/c
Dead Floor Live Snow
Vertical Loads Location (Side)Tributary Width (0.90)(1.00)(1.15)Comments
0 - Self Weight (PLF)0 to 5' 10"N/A 15.6 ----
1 - Uniform (PSF)0 to 5' 10"11' 3"15.0 40.0 -Floor - Main Level
2 - Uniform (PLF)0 to 5' 10"N/A 90.0 --Wall - Main Level
3 - Uniform (PSF)0 to 5' 10"7'10.0 40.0 -Floor - Deck
4 - Point (lb)0 N/A 8045 440 10771
Linked from: Flex
Window Rear,
Support 1
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties
related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is
responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387
and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to
www.weyerhaeuser.com/woodproducts/document-library.
The product application, input design loads, dimensions and support information have been provided by plan dated 3/30/21.
Weyerhaeuser Notes
All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal.
MEMBER REPORT PASSED
Lower Level, Bedroom# 5 Window
3 piece(s) 1 3/4" x 9 1/2" 1.55E TimberStrand® LSL
ForteWEB Software Operator Job Notes 4/28/2021 8:33:07 PM UTCJeffrey Doty, Design Supervisor
Lyman Lumber Company
(952) 470-4866
jeff_doty@lymanlumber.com
ForteWEB v3.1, Engine: V8.1.6.2, Data: V8.0.1.0
File Name: 17870 Eclipse Ave, Lakeville, MN
Topaz - Connor
17870 Eclipse Ave, Lakeville, MN
4/28/21; #24806
Page 36 / 39
Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern)
Member Reaction (lbs)1813 @ 0 1913 (1.50")Passed (95%)--1.0 D + 1.0 L (All Spans)
Shear (lbs)759 @ 10 3/4"2498 Passed (30%)1.00 1.0 D + 1.0 L (All Spans)
Moment (Ft-lbs)1397 @ 1' 6 1/2"3431 Passed (41%)1.00 1.0 D + 1.0 L (All Spans)
Live Load Defl. (in)0.006 @ 1' 6 1/2"0.103 Passed (L/999+)--1.0 D + 1.0 L (All Spans)
Total Load Defl. (in)0.009 @ 1' 6 1/2"0.154 Passed (L/999+)--1.0 D + 1.0 L (All Spans)
System : Wall
Member Type : Header
Building Use : Residential
Building Code : IBC 2018
Design Methodology : ASD
•Deflection criteria: LL (L/360) and TL (L/240).
•Allowed moment does not reflect the adjustment for the beam stability factor.
•Applicable calculations are based on NDS.
Bearing Length Loads to Supports (lbs)
Supports Total Available Required Dead Floor Live Total Accessories
1 - Trimmer - SPF 1.50"1.50"1.50"502 1310 1812 None
2 - Trimmer - SPF 1.50"1.50"1.50"502 1310 1812 None
•Maximum allowable bracing intervals based on applied load.
Lateral Bracing Bracing Intervals Comments
Top Edge (Lu)3' 1" o/c
Bottom Edge (Lu)3' 1" o/c
Dead Floor Live
Vertical Loads Location (Side)Tributary Width (0.90)(1.00)Comments
0 - Self Weight (PLF)0 to 3' 1"N/A 7.0 --
1 - Uniform (PSF)0 to 3' 1"21' 3"15.0 40.0 floor
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties
related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is
responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387
and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to
www.weyerhaeuser.com/woodproducts/document-library.
The product application, input design loads, dimensions and support information have been provided by plan dated 3/30/21.
Weyerhaeuser Notes
All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal.
MEMBER REPORT PASSED
Lower Level, Door Hdr Mech/Storage
2 piece(s) 2 x 10 Spruce-Pine-Fir No. 1 / No. 2
ForteWEB Software Operator Job Notes 4/28/2021 8:33:07 PM UTCJeffrey Doty, Design Supervisor
Lyman Lumber Company
(952) 470-4866
jeff_doty@lymanlumber.com
ForteWEB v3.1, Engine: V8.1.6.2, Data: V8.0.1.0
File Name: 17870 Eclipse Ave, Lakeville, MN
Topaz - Connor
17870 Eclipse Ave, Lakeville, MN
4/28/21; #24806
Page 37 / 39
Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern)
Member Reaction (lbs)4134 @ 1 1/2"7613 (3.00")Passed (54%)--1.0 D + 0.75 L + 0.75 S (All Spans)
Shear (lbs)3345 @ 1' 1/2"6318 Passed (53%)1.00 1.0 D + 1.0 L (All Spans)
Moment (Ft-lbs)9231 @ 4' 10 1/16"11775 Passed (78%)1.00 1.0 D + 1.0 L (All Spans)
Live Load Defl. (in)0.166 @ 4' 9"0.308 Passed (L/667)--1.0 D + 0.75 L + 0.75 S (All Spans)
Total Load Defl. (in)0.341 @ 4' 9"0.463 Passed (L/325)--1.0 D + 0.75 L + 0.75 S (All Spans)
System : Wall
Member Type : Header
Building Use : Residential
Building Code : IBC 2018
Design Methodology : ASD
•Deflection criteria: LL (L/360) and TL (L/240).
•Allowed moment does not reflect the adjustment for the beam stability factor.
Bearing Length Loads to Supports (lbs)
Supports Total Available Required Dead Floor Live Snow Total Accessories
1 - Trimmer - SPF 3.00"3.00"1.63"2085 1900 832 4817 None
2 - Trimmer - SPF 3.00"3.00"1.56"1976 1900 746 4622 None
•Maximum allowable bracing intervals based on applied load.
Lateral Bracing Bracing Intervals Comments
Top Edge (Lu)9' 6" o/c
Bottom Edge (Lu)9' 6" o/c
Dead Floor Live Snow
Vertical Loads Location (Side)Tributary Width (0.90)(1.00)(1.15)Comments
0 - Self Weight (PLF)0 to 9' 6"N/A 9.7 ----
1 - Uniform (PSF)0 to 9' 6"3'15.0 40.0 -Floor - Main Level
2 - Uniform (PSF)0 to 9' 6"1'90.0 --Wall - Main Level
3 - Uniform (PSF)0 to 9' 6"7'10.0 40.0 -Floor - Deck
4 - Point (lb)2' 6"N/A 1011 -789
Linked from: Dining
Room Back
Window, Support 2
5 - Point (lb)6' 6"N/A 1011 -789
Linked from: Dining
Room Back
Window, Support 3
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties
related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is
responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387
and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to
www.weyerhaeuser.com/woodproducts/document-library.
The product application, input design loads, dimensions and support information have been provided by plan dated 3/30/21.
Weyerhaeuser Notes
All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal.
MEMBER REPORT PASSED
Lower Level, Bump-out Window
2 piece(s) 1 3/4" x 9 1/2" 2.0E Microllam® LVL
ForteWEB Software Operator Job Notes 4/28/2021 8:33:07 PM UTCJeffrey Doty, Design Supervisor
Lyman Lumber Company
(952) 470-4866
jeff_doty@lymanlumber.com
ForteWEB v3.1, Engine: V8.1.6.2, Data: V8.0.1.0
File Name: 17870 Eclipse Ave, Lakeville, MN
Topaz - Connor
17870 Eclipse Ave, Lakeville, MN
4/28/21; #24806
Page 38 / 39
Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern)
Member Reaction (lbs)8148 @ 8' 6"11419 (4.50")Passed (71%)--1.0 D + 1.0 L (All Spans)
Shear (lbs)7257 @ 7' 4 5/8"8590 Passed (84%)1.00 1.0 D + 1.0 L (All Spans)
Moment (Ft-lbs)16313 @ 6' 3"15953 Passed (102%)1.00 1.0 D + 1.0 L (All Spans)
Live Load Defl. (in)0.181 @ 4' 6"0.275 Passed (L/548)--1.0 D + 1.0 L (All Spans)
Total Load Defl. (in)0.317 @ 4' 5 15/16"0.412 Passed (L/312)--1.0 D + 1.0 L (All Spans)
System : Wall
Member Type : Header
Building Use : Residential
Building Code : IBC 2018
Design Methodology : ASD
•Deflection criteria: LL (L/360) and TL (L/240).
•Allowed moment does not reflect the adjustment for the beam stability factor.
Bearing Length Loads to Supports (lbs)
Supports Total Available Required Dead Floor Live Snow Total Accessories
1 - Trimmer - SPF 4.50"4.50"2.58"2836 3698 396 6930 None
2 - Trimmer - SPF 4.50"4.50"3.21"3447 4701 485 8633 None
•Maximum allowable bracing intervals based on applied load.
Lateral Bracing Bracing Intervals Comments
Top Edge (Lu)6" o/c
Bottom Edge (Lu)8' 9" o/c
Dead Floor Live Snow
Vertical Loads Location (Side)Tributary Width (0.90)(1.00)(1.15)Comments
0 - Self Weight (PLF)0 to 8' 9"N/A 13.0 ----
1 - Uniform (PSF)6' 3" to 8' 9"10'15.0 40.0 -Floor - Main Level
2 - Uniform (PSF)0 to 6' 3"8'15.0 40.0 -Floor - Main Level
3 - Uniform (PSF)0 to 8' 9"1'90.0 --Wall - Main Level
4 - Point (lb)6' 3"N/A 500 990 -
Linked from: Stairs
FLR Girder, Support
2
5 - Point (lb)2' 3"N/A 1423 1653 321
Linked from: Great
Room Back
Window, Support 2
6 - Point (lb)6' 3"N/A 2334 2756 560
Linked from: Great
Room Back
Window, Support 3
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties
related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is
responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387
and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to
www.weyerhaeuser.com/woodproducts/document-library.
The product application, input design loads, dimensions and support information have been provided by plan dated 3/30/21.
Weyerhaeuser Notes
All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal.
MEMBER REPORT PASSED
Lower Level, Family Room Window
2 piece(s) 1 3/4" x 11 7/8" 1.55E TimberStrand® LSL
ForteWEB Software Operator Job Notes 4/28/2021 8:33:07 PM UTCJeffrey Doty, Design Supervisor
Lyman Lumber Company
(952) 470-4866
jeff_doty@lymanlumber.com
ForteWEB v3.1, Engine: V8.1.6.2, Data: V8.0.1.0
File Name: 17870 Eclipse Ave, Lakeville, MN
Topaz - Connor
17870 Eclipse Ave, Lakeville, MN
4/28/21; #24806
Page 39 / 39
NEW RESIDENTIAL CONSTRUCTION SWPPP VERIFICATION
This form must be completed and submitted with all new residential permit applications.
New residential building permits WILL NOT be issued without this completed form.
Project Site Address: _____________________________________________________________________
Company Name: _________________________________________________________________________
Primary Contact: _________________________________________________________________________
Phone # (24 hr Contact): ______________________ Email: ______________________________________
Description of Land Disturbing Activity: _____________________________________________________
NPDES Construction Stormwater Permit # C000 ___ ___ ___ ___ ___ or # SUB00 ___ ___ ___ ___ ___
If you are not covered under a NPDES Construction Stormwater Permit administered by the MPCA, an
erosion and sediment control plan MUST be submitted with the residential building permit application.
Contact information of person CERTIFIED to provide weekly onsite erosion and sediment control
inspections and corrective actions:
Name of Person: ________________________________Company: _______________________________
Phone # (24 hr Contact): ______________________ Email: ______________________________________
Entity that Provided Training: ________________________ Certification Expiration Date: ____________
NOTE: Prior to any land-disturbing activity, all erosion and sediment controls must be installed on the project site and on individual lots.
No land disturbing activity may begin until a residential building permit has been issued.
I understand, the above information to be true and I will have read, understood, and accepted all terms and conditions of the National
Pollutant Discharge Elimination System (NPDES) Permit (MN R 100001). The City of Lakeville may issue a STOP WORK ORDER;
withhold building inspections; or, draw on securities/escrows to bring the site into compliance with the NPDES Construction Stormwater
Permit (MN R 100001) or erosion and sediment control plan.
Signature: ________________________________________________ Date:_________________________
Contact the City of Lakeville with questions at erosion@lakevillemn.gov or 952-985-4500
* If awaiting a MPCA permit transfer, provide MPCA proof of transfer submittal e-mail along with this form to
erosion@lakevillemn.gov
“The permittee(s) shall ensure that the individuals are trained by local, state, federal agencies, professional organizations or other entities in erosion prevention, sediment control, permanent Stormwater management and the Minnesota NPDES/SDS Construction Stormwater Permit.” (NPDES Construction Stormwater Permit, MPCA)
“The permittee(s) must ensure that a trained person (as identified in Part III.A.3.a) will routinely inspect the entire construction site at least once every seven (7) days during active construction and within 24 hours after a rainfall event greater than 0.5 inches in 24 hours.” (NPDES Construction Stormwater Permit, MPCA)
X05/17/21
X