HomeMy WebLinkAboutLA193654 Approved Charles Moore Solar Drawings wStamp 7 28 2021EXISTINGSNAPNRACKSITE MAP & PV LAYOUTELECTRICAL 1-LINE DIAGRAM ATTACHMENT LAYOUTSYSTEM LABELING DETAILENPHASE RAPID SHUTDOWNINVERTER DATA SHEETSHEET INDEXPROPERTY PLANMODULE DATA SHEETRACKING DATA SHEETATTACHMENT DATA SHEETPV 1.0PV 2.0PV 4.0PV 5.0PV 6.0D 7.0D 8.0D 9.0D 10.0D 11.0SYSTEM RATINGEQUIPMENT SUMMARYELECTRICAL INFORMATIONMAIN SERVICE PANEL BUS SIZE:MAIN SERVICE BREAKER SIZE:MOUNTING SYSTEM:BUILDING INFORMATIONCONSTRUCTION TYPE: V-BOCCUPANCY: R3ROOF:Truss 2 x 4 @ 24" O.C.Comp ShingleVICINITY MAP (SCALE: NTS)SATELLITE VIEW (SCALE: NTS)GENERAL NOTES1.All electrical materials shall be new and listed by recognizedelectrical testing laboratory Custom made equipment shall have complete test data submittedby the manufacturer attesting to its safety2.Outdoor equipment shall be NEMA 3R rated or equivalent3.All metallic equipment shall be grounded4.Contractor shall obtain electrical permits prior to installation andshall coordinate all inspections, testing commissioning andacceptance with the client, utility co. and city inspectors as needed.5.The electrical contractor shall verify the exact locations of servicepoints and service sizes with the serving utility company andcomply with all utility companies requirements.6.Drawings are diagrammatic only, routing of raceways shall beoption of the contractor unless otherwise noted and shall becoordinated with other trades.7.If the roof material or the roof structure not adequate for PVinstallation, call the engineer of record print to installation. Thecontractor is responsible to verify that the roof is capable ofwithstanding the extra weight.8.If the distances for cable runs are different than shown, thecontractor shall notify the electrical engineer to validate the wiresize. Final drawings will be red-lined and updated as appropriate.9.Whenever a discrepancy in quality of equipment arises on thedrawing or specifications, the contractor shall be responsible forproviding and installing all materials and services required by thestrictest conditions noted on the drawings or in the specificationsto ensure complete compliance and longevity of the operablesystem required by the engineer of record.PHOTOVOLTAIC NOTES:1.Rooftop mounted photovoltaic panels and modules shall be tested,listed and identified by recognized testing laboratory2.Solar system shall not cover any plumbing or mechanical vents3.Modules and support structures shall be grounded unless racking has integrated ground.4.Removal of an interactive inverter or other equipment shall notdisconnect the bonding connection between the groundingelectrode conductor and the photovoltaic source and/or outputcircuit grounded conductors.5.All PV modules and associated equipment and wiring shall beprotected from physical damage.6.Live parts of PV source circuits and PV output circuits over 150v toground shall not be accessible to other than qualified persons while energized.7.Inverter is equipped with integrated DC disconnect, thus providingground fault protection8.All conductors shall be copper and 75 deg rated9.A single conductor shall be permitted to be used to perform themultiple functions of dc grounding, AC grounding and bondingbetween AC and DC systems.10.Non-current carrying metal parts of equipment shall be effectivelybonded together. Bond both ends of raceways.200A200A07/28/2021Property Address:Owner:Charles MooreProperty Type:Single Family ResidenceDrawn by:support@solarpaperwork.comDate:DC 9.750KW STCAC 9.074 KW STC26 JINKO 375 WATT MODULESWITH IQ7A MICROINVERTERS20819 Gemini Tr Lakeville, MN 55044CONTRACTORAddress:101 Isanti ParkwayNE, Isanti, MN 55040Phone number: (763) 229-6662E-mail: contact@wolfriverelectric.comTHE INSTALLATION OF SOLAR ARRAYS ANDPHOTOVOLTAIC POWER SYSTEMS SHALL COMPLY WITHTHE FOLLOWING CODES:·2020 National Electrical Code·2018 International Building Code·2018 International Residential Code·2020 Minnesota Residential Code·2020 Minnesota Building Code·2020 Minnesota Energy Code·2020 Minnesota Accessibility Code·2020 Minnesota State Fire Code·2018 International Fire Code·2018 International Energy Conservation Code·2018 Mechanical CodeAS ADOPTED BY THE STATE OF MINNESOTAALL OTHER ORDINANCE ADOPTED BY THELOCAL GOVERNING AGENCIESGOVERNING CODESINVERTER CERTIFICATIOND 13.0PV 3.0ENPHASE AC COMBINER BOXD 12.0PV INSPECTION CHECKLIST ATTACHMENT DETAILPV 5.1SURGE PROTECTIOND 14.0Date Certified andSigned: 7/28/2021
SOLAR MODULES___Jinko 375 WattModel # JKM375-6RL3-BEMT type ConduitSolar Module(N) Junction BoxJB.................................................................................26MSP(E) Main Service Panel200AINDEX(N) Production MeterPM..............AC....................(N) 60A Utility AC(N) Microinverter26INVERTERINVERTER TYPE: Micro:___ Enphase IQ7AModel # IQ7A-72-2-US(240V)NOTE: Conduit in attic shallbe minimum 18 inches from roof sheating* Roof access is not located in areas that require placement of ground ladders over exterior wall openings.SITE MAP & PVLAYOUTPV 1.0PV SYSTEMAS INDICATEDScale:Project:Drawn by:support@solarpaperwork.comSolarPaperwork.comProject Name:Property Adress:07/28/2021Charles Moore20819 Gemini TrLakeville, MN 55044DATE:CONTRACTORECB(N) Enphase Combiner Box....Wolf RIver ElectircAddress:101 Isanti ParkwayNE, Isanti, MN 55040Phone number: (763) 229-6662E-mail: contact@wolfriverelectric.comEQUIPMENT ELEVATIONDakota Electric Application:#TBDNote: 24/ 7 Unescorted keyless access is to beprovided for ALL UTILITY EQUIPMENTNOTE: No clearance issue Distance between all equipments is maximum 10"(E) Main MeterMM........................Fire Setback Line.............SECONDARY INTERCONNECTIONFMT type Conduit.............NOTE:A 36-inchwide pathwayshall be provided to the emergencyescape and rescue opening.From roofMainServicePanelECBUtility ACDisconnectProductionMeter10"4'MainMeterOutsideOutsideInsideInside<10'10"3'
f
i
r
e
s
e
t
b
a
c
k3' fire setback3' fire pathway3' fire setbackMMMSPPMACECBG
e
m
i
n
i
T
r
aSolar PV Array 123 - Jinko 375W Modules23 - IQ7A MicroinvertersPitch: 27 DegOrientation: 133 Deg''Roof Access''JB2aaaabbbbbbbbbccccccccJB3JB1''Roof Access''3' fire setback3'
f
i
r
e
s
e
t
b
a
c
k
aaaaSolar PV Array 23 - Jinko 375W Modules3 - IQ7A MicroinvertersPitch: 30 DegOrientation: 223 DegSCALE:3/32" = 1'-0" 180° 90° 270°0°SWNE
MAIN METER(3) #6 AWG THWN/THWN-2(1) #6 AWG GND3/4" EMT, 2 FEETENPHASE Q CABLE(2) #12 AWG PV WIRE(1) #6 AWG EGCFREE IN THE AIRPV 2.0PV SYSTEMAS INDICATEDScale:Project:Project Name:Property Adress:Charles Moore20819 Gemini TrLakeville, MN 55044ELECTRICAL 1-LINE DIAGRAMCONTRACTOREnphasePV MONITORING DEVICEENPHASE AC COMBINER BOX120/240V, NEMA 3R(2) #14 AWG THWN/ THWN-210A 2-POLEJINKO 375 WATT MODULES2626ENPHASE IQ7A MICROINVERTERSDakota Electric Application:#TBDNote: 24/ 7 Unescorted keyless access is to beprovided for ALL UTILITY EQUIPMENTNote: Production Meter lockable and have lever-bypass Utility AC disconnect visible-open type lockable and readily accessible Microinverters are UL 1741 certified (See Inverter Data sheet)PV Production meter socket musthave lever bypass/bypassProduction meter is required based on the der sizeand program under which the application is submittedNo loads or energy storage systems shall be connected onthe DER side of the production meter In locations where there is no local Public Authority, the customer is exempt frominspection, and/or the service has been shut off or disconnected for more than 365 days (1 year),the licensed electrician or wireman shall submit a signed and dated Dakota Electric Electrical Inspection Certificate to the Company’s Builders Call Line attesting that the electrical installationhas been completed and installed according to the current National Electrical Code®, the DakotaElectric Standard for Electric Installation and Use, and any other applicable codes that apply beforeelectric service is energized.Design meet National Electric Code(NEC codes)For smaller DERs, using the PoC as theReference Point of Applicability allows the DERequipment type testing certification to be utilizedas the main method by which compliancewith the Standard is verified. The PoC might bethe terminals of an inverter, for example,and utilizing a UL 1741 certified and listed inverterwould be sufficient to demonstrateStandard compliance.SQUARE-D-200A PVproduction meter socket withstamped brass aluminium orstainless steel tag labeled inaccordance with NEC andAHJ requirmentslocated within 5' of main.Inverter output wired to loadside terminal of meter1 phase 3-wire 120/240V60A FUSED AC DISCONNECT,WITH 50A FUSESUTILITY AC DISCONNECT VISIBLE-OPENLOCKABLE, READILY ACCESSIBLENEMA3R120 / 240V37.7ALine37.7AINSTALL (3)20A PV2-POLE C/BWolf RIver ElectircAddress:101 Isanti ParkwayNE, Isanti, MN 55040Phone number: (763) 229-6662E-mail: contact@wolfriverelectric.com(3) #6AWG THWN/THWN-2(1) #6 AWG GND3/4" EMT, 2 FEETEXISTING______ MAINSERVICEPANEL120/240V,1P, 3WGEC(E) GROUNDINGELECTRODE SYSTEM200ANON CENTER _____MAIN C/B200ANOTE: Service Panel does not contain center fed Main Breaker:SYSTEM RATING AND DER POWER OUTPUTDC 9.750KW STSAC 9.074KW STSINVERTER:ENPHASE IQ7A-72-2-USINVERTER MAXIMUM CONTINUOUS OUTPUT:349VASYSTEM POWER OUTPUT:26 x 349=9.0741-PHASE MICRO-INVERTER UL1741SECONDARY INTERCONNECTIONREFERENCE POINT OF APPLICABILITYJ BOX#2NEMA3R13.05AENPHASE IQ7A MICROINVERTERS1 PHASE 349VAMAXIMUM OUTPUT CURRENT 1.45AAC PORT BACKFEED CURRENT 0ADC SHORT CIRCUIT CURRENT 15A (6) #10 AWG THWN/THWN-2 (1) #8 AWG GND 3/4'' EMT, 7 FEET12BRANCHCIRCUIT - B9Location subject to current Dakota Electric meterrequirements and approvalSupply Side tapAtticWall (6) #10 AWG THWN/THWN-2 (1) #8 AWG GND 3/4'' FMT, 20 FEETThe lockable visible disconnect must be located within 5 feet from the GeneralService Meter and must be located onthe exterior of the buildingATT:PLEASE REFER TO WH NETMEETERING GUIDE:APPENDIX GMeter Socket must be 200A ratedand must have lever BypassLoad37.7A(3) #6 AWG THWN/THWN-2(1) #6 AWG GND3/4" EMT, 2 FEET12BRANCHCIRCUIT - A 12BRANCHCIRCUIT - A8.7A4.35ASurge ProtectionMNSPD-300-AC120/240V,1P, 3WDC 9.750 KW STCAC 9.074 KW STCDrawn by:support@solarpaperwork.comSolarPaperwork.com07/28/2021DATE:6J BOX#2NEMA3R11.6A12BRANCHCIRCUIT - C J BOX#3NEMA3R3J BOX#1NEMA3R8
SYSTEM LABELING DETAILPV 3.0PV SYSTEMAS INDICATEDScale:Project:Project Name:Property Adress:Charles Moore20819 Gemini TrLakeville, MN 55044CONTRACTORPV ARRAYJ BOXPV SUB-PANELACDISCONNECTPVPRODUCTIONMETERMAIN SERVICEPANELMETER12333331617218135Note: LABELS SHALL COMPLY WITH NEC 690“Labels shall be weatherproof, durable and permanently mounted”37.7AProduction MeterLABEL 1Photovoltaic Power SourceLABEL 2CAUTION: SOLAR CIRCUITLABEL 3WARNINGELECTRIC SHOCK HAZARDTHE DC CONDUCTORS OF THISPHOTOVOLTAIC SYSTEM AREUNDERGROUND AND MAY BE ENERGIZEDLABEL 4WARNINGELECTRIC SHOCK HAZARDIF GROUND FAULT IS INDICATEDNORMALLY GROUNDED CONDUCTORSMAY BE UNDERGROUND AND ENERGIZEDLABEL 5WARNINGELECTRIC SHOCK HAZARDDO NOT TOUCH TERMINALSTERMINALS ON BOTH LINE AND LOADSIDES MAY BE ENERGIZED IN THE OPENPOSITIONLABEL 6WARNINGELECTRIC SHOCK HAZARDDO NOT TOUCH TERMINALSTERMINALS ON BOTH LINE AND LOADSIDES MAY BE ENERGIZED IN THE OPENPOSITIONDC VOLTAGE IS ALWAYS PRESENTWHEN SOLAR MODULESARE EXPOSED TO SUNLIGHTLABEL 7WARNINGLABEL 8TURN OF PHOTOVOLTAICAC DISCONNECT PRIOR TOWORKING INSIDE PANELDO NOT DISCONNECTUNDER LOADLABEL 9MAIN PV SYSTEMDISCONNECTLABEL 10MAIN PV SYSTEMAC DISCONNECTLABEL 11LABEL 12CAUTIONLABEL 13SOLAR ELECTRIC SYSTEMCONNECTEDWARNING-LABEL 14 DUAL POWER SOURCESECOND SOURCE IS PV SYSTEMCAUTIONLABEL 15PHOTOVOLTAIC SYSTEM CIRCUITIS BACKFEDLABEL 16PHOTOVOLTAIC AC DISCONNECTMAXIMUM AC OPERATING CURRENTMAXIMUM AC OPERATING CURRENTPHOTOVOLTAICLABEL 17UTILITY AC DISCONNECTPHOTOVOLTAICLABEL 18DC DISCONNECTNOMINAL OPERATING AC VOLTAGENOMINAL OPERATING AC FREQUANCYMAXIMUM AC POWERMAXIMUM AC CURRENTMAX OCERCURRENT DEVICE RATINGFOR AC MODULE PROTECTIONLABEL 19LABEL 20PV SYSTEM DC DISCONNECTOPERATING CURRENTOPERATING VOLTAGEMAXIMUM SYSTEM VOLTAGESHORT CIRCUIT CURRENTRATED MAX POWER-FONT CURRENTRATED MAX POWER-FONT VOLTAGEMAXIMUM SYSTEM VOLTAGESHORT CIRCUIT CURRENTMAX RATED OUTPUT CURRENT OFTHE CHARGE CONTROLLER IF INSTALLEDLABEL 21***ALL LABELS = RED THERMOPLASTIC/REFLECTIVE , Permanently mounted240VSOLAR DISCONNECTWolf RIver ElectircAddress:101 Isanti ParkwayNE, Isanti, MN 55040Phone number: (763) 229-6662E-mail: contact@wolfriverelectric.com21Drawn by:support@solarpaperwork.comSolarPaperwork.com07/28/2021DATE:
PROPERTY PLANLEGENDMSPMain Service Panel................ Production MeterPM..................... AC DisconnectAC........................PV 4.0PV SYSTEMAS INDICATEDScale:Project:Project Name:Property Adress:Charles Moore20819 Gemini TrLakeville, MN 55044CONTRACTOREnphase Combiner BoxECB..........Dakota Electric Application:#TBDNote: 24/ 7 Unescorted keyless access is to beprovided for ALL UTILITY EQUIPMENTWolf RIver ElectircAddress:101 Isanti ParkwayNE, Isanti, MN 55040Phone number: (763) 229-6662E-mail: contact@wolfriverelectric.comMMMain Meter............................Drawn by:support@solarpaperwork.comSolarPaperwork.com07/28/2021DATE:MMMSPPMACECBGemini Tr
135'-5"127'-11"104'136'-4"50'-10"67'30'64'-3"116'15'-3"55'-6"PROPERTY LINEGATEDRIVEWAYSCALE:1/16" = 1'-0" 180° 90° 270°0°SWNEDate Certified andSigned: 7/28/2021
ATTACHMENTLAYOUTDESIGN CRITERIAModules:Max Distributed Load: 3 PSFPOINT LOAD CALCULATION PER ARRAYModule Weight (lbs)# Of Modules46.96Total Module Weight (lbs)Rack Weight (lbs)MicroInverters Weight (lbs)Total System Weight (lbs)# Of StandoffsMax Span Between Standoffs (in)Loading Per Standoff (lbs)Total Area (sq.ft.)Loading (PSF)1220.96244.19261.881527.032844818.175202.93RAIL ATTACHMENTMODULES ON ROOFTruss 2 x 4 @ 24" O.C.2626PV 5.0PV SYSTEMAS INDICATEDScale:Project:Project Name:Property Adress:Charles Moore20819 Gemini TrLakeville, MN 55044CONTRACTORDakota Electric Application:#TBDNote: 24/ 7 Unescorted keyless access is to beprovided for ALL UTILITY EQUIPMENTWolf RIver ElectircAddress:101 Isanti ParkwayNE, Isanti, MN 55040Phone number: (763) 229-6662E-mail: contact@wolfriverelectric.com1 Layer of .Plywood & Building FeltSolar Module6"AttachmentMODULES ON ROOFTruss 2 x 4 @ 24" O.C.Comp ShinglePrior to the commencement of work, the contractor shall verify the existing roof and framingconditions. Notify support@SolarPaperwork.com of any Discrepancies prior to startingconstruction. Prior to the commencement of work, the contractor shall inspect framing forany damage such as water damage, cracked framing, etc. and These Plans are stampedfor structural code compliance of the roof framing supporting the proposed PV installationreference only. These plans are not stamped for water leakage. PV modules, racking, andattachment components must follow manufacturer guidelines and requirements.Attachments to be installed in a staggered orientation to properly distribute loads.1.86"3.05"0.25"Ø2.24"2.58"1"0.17"3.20"1.37"0.38"0.30"1.08"2.78"1.78"1.50"1.99"1.21"R 1.12"Ø0.33"R 0.82"12345SNAPNRACK, SPEEDSEAL FOOT, BASE, SEALING, SILVER/BLACKBOLT, FLANGE, SERRATED, 5/16IN-18 X 2IN, SSSNAPNRACK, RL UNIVERSAL, MOUNT SPRING, SSSNAPNRACK, ULTRA RAIL MOUNT THRU PRC, CLEAR/BLACKSNAPNRACK, ULTRA RAIL MOUNT TAPPED PRC, CLEAR/BLACK12345DESCRIPTIONITEMQTI11111MATERIALS:DESIGN LOAD (LBS):ULTIMATE LOAD (LBS):TORQUE SPECIFICATION:CERTIFICATION:WEIGHT (LBS):DIE CAST A380 ALUMINUM, 6000 SERIES ALUMINUM, STAINESS STEEL802 UP, 1333 DOWN, 357 SIDE2118 UP, 4006 DOWN, 1331 SIDE12 LB-FTUL 2703, FILE E359313; WIND-DRIVEN RAIN TEST FROM SUBJECT UL 25820.45OPTIONS:CLEAR/BLACKPARTS LISTSNAPNRACK, ULTRA RAIL SPEEDSEAL TM FOOT2x4PurlinDrawn by:support@solarpaperwork.comSolarPaperwork.com07/28/2021DATE:Date Certified andSigned: 7/28/2021
PV 5.1PV SYSTEMAS INDICATEDScale:Project:Project Name:Property Adress:Charles Moore20819 Gemini TrLakeville, MN 55044ATTACHMENT DETAILCONTRACTORWolf RIver ElectircAddress:101 Isanti ParkwayNE, Isanti, MN 55040Phone number: (763) 229-6662E-mail: contact@wolfriverelectric.comDrawn by:Areg AghayantsSolarPaperwork.comsupport@solarpaperwork.com07/28/2021DATE:
INVERTERDATA SHEETD 6.0PV SYSTEMAS INDICATEDScale:Project:Project Name:Property Adress:Charles Moore20819 Gemini TrLakeville, MN 55044CONTRACTORWolf RIver ElectircAddress:101 Isanti ParkwayNE, Isanti, MN 55040Phone number: (763) 229-6662E-mail: contact@wolfriverelectric.comDrawn by:support@solarpaperwork.comSolarPaperwork.com07/28/2021DATE:
ENPHASE RAPIDSHUTDOWN,COMPATIBILITY WITH PVD 7.0PV SYSTEMAS INDICATEDScale:Project:Project Name:Property Adress:Charles Moore20819 Gemini TrLakeville, MN 55044CONTRACTORWolf RIver ElectircAddress:101 Isanti ParkwayNE, Isanti, MN 55040Phone number: (763) 229-6662E-mail: contact@wolfriverelectric.comDrawn by:support@solarpaperwork.comSolarPaperwork.com07/28/2021DATE:
MODULEDATA SHEETD 8.0PV SYSTEMAS INDICATEDScale:Project:Project Name:Property Adress:Charles Moore20819 Gemini TrLakeville, MN 55044CONTRACTORWolf RIver ElectircAddress:101 Isanti ParkwayNE, Isanti, MN 55040Phone number: (763) 229-6662E-mail: contact@wolfriverelectric.comDrawn by:support@solarpaperwork.comSolarPaperwork.com07/28/2021DATE:
RACKINGDATA SHEETD 9.0PV SYSTEMAS INDICATEDScale:Project:Project Name:Property Adress:Charles Moore20819 Gemini TrLakeville, MN 55044CONTRACTORWolf RIver ElectircAddress:101 Isanti ParkwayNE, Isanti, MN 55040Phone number: (763) 229-6662E-mail: contact@wolfriverelectric.comDrawn by:support@solarpaperwork.comSolarPaperwork.com07/28/2021DATE:
ATTACHMENTDATA SHEETD 10.0PV SYSTEMAS INDICATEDScale:Project:Project Name:Property Adress:Charles Moore20819 Gemini TrLakeville, MN 55044CONTRACTORWolf RIver ElectircAddress:101 Isanti ParkwayNE, Isanti, MN 55040Phone number: (763) 229-6662E-mail: contact@wolfriverelectric.comDrawn by:support@solarpaperwork.comSolarPaperwork.com07/28/2021DATE:
D 11.0PV SYSTEMAS INDICATEDScale:Project:Project Name:Property Adress:Charles Moore20819 Gemini TrLakeville, MN 55044CONTRACTORENPHASEAC COMBINER BOXDATASHEETWolf RIver ElectircAddress:101 Isanti ParkwayNE, Isanti, MN 55040Phone number: (763) 229-6662E-mail: contact@wolfriverelectric.comDrawn by:support@solarpaperwork.comSolarPaperwork.com07/28/2021DATE:
D 13.0PV SYSTEMAS INDICATEDScale:Project:Project Name:Property Adress:Charles Moore20819 Gemini TrLakeville, MN 55044CONTRACTORINVERTERCERTIFICATIONWolf RIver ElectircAddress:101 Isanti ParkwayNE, Isanti, MN 55040Phone number: (763) 229-6662E-mail: contact@wolfriverelectric.comDrawn by:support@solarpaperwork.comSolarPaperwork.com07/28/2021DATE:
D 12.0PV SYSTEMAS INDICATEDScale:Project:Project Name:Property Adress:Charles Moore20819 Gemini TrLakeville, MN 55044CONTRACTORSURGE PROTECTIONWolf RIver ElectircAddress:101 Isanti ParkwayNE, Isanti, MN 55040Phone number: (763) 229-6662E-mail: contact@wolfriverelectric.comDrawn by:support@solarpaperwork.comSolarPaperwork.com07/28/2021DATE:
D 14.0PV SYSTEMAS INDICATEDScale:Project:Project Name:Property Adress:Charles Moore20819 Gemini TrLakeville, MN 55044PV INSPECTIONCHECKLISTCONTRACTORWolf RIver ElectircAddress:101 Isanti ParkwayNE, Isanti, MN 55040Phone number: (763) 229-6662E-mail: contact@wolfriverelectric.comWolf RIver ElectricLakeville, MN 5504420819 Gemini TrDrawn by:support@solarpaperwork.comSolarPaperwork.com07/28/2021DATE: