HomeMy WebLinkAboutLA190217 20177 Harvest Dr Permit PackRESIDENTIAL BUILDING
PERMIT APPLICATION
CITY OF LAKEVILLE
BUILDING INSPECTIONS DEPARTMENT
20195 HOLYOKE AVENUE
LAKEVILLE, MN 55044
952-985-4440
Office Use Only
__________________
Permit Number
___________________
Received By
___________________
Date Received
___________________
Fee Total
SITE ADDRESS:
MAILING ADDRESS: CITY: STATE: ZIP:
JOB DESCRIPTION:__________________________________ MASTER PLAN: (Number or Address)____________________
LIST OTHER STRUCTURES ON PROPERTY:_______________________________________________________________
ESTIMATED VALUATION: PROPOSED START DATE: END DATE:
(New Residential Only): LEGAL DESCRIPTION: LOT: _____ BLOCK: _____ SUBDIVISION:
APPLICANT IS: RESIDENT OWNER CONTRACTOR EMAIL
NEW MODEL HOME: YES NO (IF YES – ADMINISTRATIVE PERMIT REQUIRED)
PLEASE FILL OUT THE FOLLOWING COMPLETELY (All Contractor information must be as listed on State License)
RESIDENT OWNER
NAME:_______________________________________________________________________________
HOME PHONE #:_____________________________ CELL PHONE:___________________________
GENERAL CONTRACTOR
Homeowner
Contractor
CONTRACTOR:_______________________________________________________________________
LICENSE #:BC______________ LEAD CERTIFICATE#_______________ (PRE 1978 STRUCTURE)
OFFICE PHONE #:_____________________________ CELL PHONE:___________________________
ADDRESS:____________________________ CITY:________________ ST:______ ZIP:____________
PLUMBING WORK
Homeowner
Contractor
CONTRACTOR:__________________________________________LICENSE #: PM______________
OFFICE PHONE #:_____________________________ CELL PHONE:___________________________
ADDRESS:____________________________ CITY:________________ ST:______ ZIP:____________
MECHANICAL WORK
Homeowner
Contractor
CONTRACTOR:________________________________________ _______________________________
OFFICE PHONE #:_____________________________ CELL PHONE:___________________________
ADDRESS:____________________________ CITY:________________ ST:______ ZIP:____________
BOND #:_______________________________________ EXPIRATION DATE____________________
SEWER/WATER CONTRACTOR
New Construction Only
NAME:________________________________________________ ______________________________
HOME PHONE _____________________________ CELL PHONE:______________________________
BOND #:_______________________________________ EXPIRATION DATE____________________
INTEREST EARNINGS ON THE ESCROW ACCOUNTS, IF ANY, ARE RETAINED BY THE CITY TO OFFSET THE
ADMINISTRATIVE COSTS ASSOCIATED WITH PROCESSING THE ESCROW APPLICATION AND REFUND. I HEREBY
APPLY FOR A BUILDING PERMIT AND I ACKNOWLEDGE THAT THE INFORMATION ABOVE IS COMPLETE AND
ACCURATE; THAT THE WORK WILL BE IN CONFORMANCE WITH THE ORDINANCES AND CODES OF THE CITY AND
WITH THE STATE BUILDING CODE, THAT I UNDERSTAND THIS IS NOT A PERMIT AND WORK IS NOT TO START
WITHOUT A PERMIT AND THAT THE WORK WILL BE IN ACCORDANCE WITH THE APPROVED PLAN.
NAME OF APPLICANT (Please Print)DATE
APPLICANT’S SIGNATURE:
www.lakevillemn.gov
RESIDENTIAL BUILDING PERMIT APPLICATION
PAGE 2
OFFICE USE ONLY
BUILDING PERMIT TYPE REQUIRED INSPECTIONS
SINGLE FAMILY DWELLING BUILDING
DUPLEX AS BUILT
TOWNHOUSE UNITS BUILDING FINAL
DETACHED TOWN HOUSE UNIT DECK FOOTING
CONDO FIREPLACE
ACESSORY BUILDING FOOTING
REROOF FOUNDATION
RESIDE FRAMING
PORCH FRAMING
GARAGES
INSULATION
RES ADDN/REPAIR/RMDL
DECK
PORCH
GARAGES LATH
LOWER LEVEL FINISH LOWER LEVEL FINAL
ADDITION OTHER
FOUNDATION ONLY PORCH FOOTING
MISCELLANEOUS POURED WALL
DEMO SEPTIC TANK REMOVAL
MOVED SITE
MECHANICAL
CITY BUILDING VALUATION: $AIR TEST
FINAL
BUILDING PERMIT FEES ROUGH-IN
$PERMIT FEE PLUMBING
$PLAN CHECK FINAL
$SURCHARGE ROUGH-IN
$METRO SAC METER SIZE
$CITY WATER HOOKUP UNIT PRESSURE REDUCING VALVE
$CITY SEWER HOOKUP UNIT SEWER/WATER
$LANDSCAPE ESCROW SEWER/WATER
$TREE ESCROW FINAL
$MISC ESCROW STREET DRAINTILE
$PLUMBING BUILDING INFORMATION
$MECHANICAL TYPE OF CONSTRUCTION
$SEWER WATER ZONING
$OTHER CODE EDITION
$TOTAL FIRE SUPPRESSION SYSTEM
OCCUPANCY GROUP
APPROVED BY:
BUILDING INSPECTOR: Date:
PLUMBING/MECHANICAL
INSPECTOR: Date:
COMMENTS:
20195 Holyoke Avenue, Lakeville, MN 55044
952-985-4400 952-985-4499 fax
www.lakevillemn.gov
Sewer & Water Tie Card
Address:________________________________________
Contractor:______________________________________
Permit Number:__________________________________
Final Date:________________
Street Drain-Tile:______
Size of Water Service: 1”
Comments: AIRTEST SANITARY OVER 20’/2 FITTINGS
THIS CARD MUST BE COMPLETED AND ON-SITE AT TIME
OF SEWER & WATER INSPECTION
*ALL DOOR & WINDOW HEADERSTO BE S.P.F. #2 OR BETTERRESIDENCE FOR:written consent of Planco MN, Inc. modified or used in any redesign without the priormay not be assigned or copied, and may not bemay not be re-used for any additional structures,structure. Planco MN reserves all rights. These planslicense is granted to use these plans to build oneCopyright for these drawings is owned by Planco MN,Planco MN, Inc.cWHITNEY MEESTER#21-030SMA162021STONE COTTAGE CONSTRUCTION, INC. FRONT ELEVATION 1/4" = 1'-0" 9x8 OVH. DR.16x8 OVH. DR.8128128/12612VINYLB & BVINYLB & B4" TRIM4" TRIMSTONE CAPWRAPSTONE 24"4'-6"1'-6"WOOD PORCHSTONEON JOGWRAPSTONE 24"GLASS @ TOP PANELGLASS @ TOP PANELTOTAL2nd FLR.1st FLR.1,123 SQ. FT.1,236 SQ. FT.2,359 SQ. FT.8'-4" POURED FOUNDATION9' CEILING @ FIRST FLOOR4" VINYL SIDINGSIMONTON WDWS.STONE AS SHOWNFRONT ONLYGRIDS IN WDWS.FRONT & SIDESALL SIDESVINYL B & BFRONT ONLY12x12 BOXED COL.ON 18"x18"x42"STONE BASE8" BOXED BEAM4" VINYLSIDING4" TRIMALL SIDES74/1212VINYLVINYLB & BB & BTOTALBSM'T719 SQ. FT.3,078 SQ. FT. LEFT ELEVATION 1/8" = 1'-0" SIDINGVINYL VINYLCORNERSSIDINGVINYL 8121'-0"2'-0"4" TRIM1262'-0"1'-9"712 RIGHT ELEVATION 1/8" = 1'-0" VINYLCORNERSSIDINGVINYL 8121'-5"1262'-0"712 REAR ELEVATION 1/8" = 1'-0" SIDINGVINYL VINYLCORNERSSIDINGVINYL 8121271'-6"6/12Concept Approval ONLYSubject to Field InspectionInspectorDate2020MN BldgCode04/29/2021dmathewsConcept Approval ONLYSubject to Field InspectionInspectorDate2020MN BldgCode08/12/2021dmathewsAdded Deck and L/L Finish
Planco MN, Inc.C#21-030SMA262021 BASEMENT PLAN 1/4" = 1'-0" UNEXCAVATED UP15 R2868WHFURNF.D.92% FAMILY/REC RM *CARPET BEDROOM *CARPET MECH/STORAGE *UNFINISHED11'-0"36'-0"15'-0"14'-0"7'-0"50'-0"
22'-6"27'-6"
6'-0"21'-6"20'-6"2'-0"47'-0"30'-0"17'-0"11'-0"19'-0"8'-0"14'-0"11'-0"50'-0"
8'-0"10'-8"7'-4"18'-0"
6'-6"
3'-8"3'-8"4'-4"5'-0"6'-6"30"x30"x12"CONC. PAD FTG.30"x30"x12"CONC. PAD FTG.18'-6"8'-4" POURED FOUNDATIONWALLEDGEWALLEDGE5'-8"15'-10"20x8 FTG.TRT. 4x4 CURB2x4 - 16" O.C.20x8 FTG.TRT. 4x4 CURB2x4 - 16" O.C.20x8 FTG.TRT. 4x6 CURB2x6 - 16" O.C.20x8 FTG.TRT. 4x6 CURB2x6 - 16" O.C.2-11 7/8" LSL DROPPED11 7/8" LSL
JOISTS 6x6 POSTSUMPRADONVENT6" CANT.2" LEDGESD/CO),1,6+('64)7(;&/8'(667$,56LOOKOUT
LOOKOUT WALKOUTWALKOUTWALKOUT9068 P.D.50682668266830"4834NO FTG.@ TOILET2-2x10(2) TRT. 6x6 POSTON 12x16 PIER FTG.24x24 FROST FTG.9"7'-6"8'-9"TRT. 2-2x10 FLUSHTRT. 2-2x10 FLUSHTREATED
2x8
16" O.C.
11 7/8" LSL
JOISTS
11 7/8" LSL
JOISTS 3-2x106/0x5/0 SL7'-2"7'-10"7'-0"7'-0"3-2x10 CONC. PATIO *14x106'-0"2-2x103-11 7/8" LVL DROPPED2868 STORAGE *UNFINISHED19'-0"1'-2"1-11 7/8" LSLFLUSH1 PIECE FIB.FSD8'-10"3'-6"*VINYLTRT. 6x6 POSTON 18"x42" CONC.TUBE FTG.7'-0"7'-0"7'-0"TRT. 2-2x10 FLUSHTRT. 2-2x10 FLUSHTRT. 2-2x10 FLUSHTRT. 2-2x10 FLUSH10'-0"
14'-0"
TREATED
2x10
16" O.C.
TREATED
2x10
16" O.C.UFER Ground-Provide 20' Rebar in footing and stubup near electrical service panel.HD-1HD-1HD-1HD-1Sill plates fastened to concrete w/ 1/2" anchor bolts 4' O.C. and 1' fromall ends and openingsExterior Walls (Lower level) UNO:(1) 2x6" SPF #2 or better 16" O.C. w/ 7/16" OSB fastened to studs and plates w/ 8d nails 6" O.C. at all edges and 12" O.C. in the field. (3)2x10 min for point load fromlarge landing deck area beam.
Temper(1) 2x6" SPF #2 or better 16" O.C. w/7/16" OSB fastened to studs and plates w/ 8d nails 4" O.C. at all edges and 8" O.C. in the field. Block all seams solid. BW-1BW-1BW-1BW-1(1) 2x6" SPF #2 or better 16" O.C. w/ 1/2" (min) gypsum board fastened to studs/ plates w/ #9 screws 4" O.C. at all edges and 6" in the field.BW-2BW-2BW-2PFHPFH(2) 11-7/8" LVL min perbraced wall engineeringHD-2HD-2HD-1HD-1HD-1Sill plates fastened to concrete w/ 1/2" anchor bolts 4' O.C. and 1' fromall ends and openingsTruss blocking per Figure 3/S4.
Exterior Walls (2nd level):(1) 2x6" SPF #2 or better 16" O.C. w/ 7/16" OSB fastened to studs andplates w/ 8d nails 6" O.C. at all edges and 12" O.C. in the field. HD-2HD-2HD-2-Min. 15" clearance to anyobstruction from center ofW.C., 24" in front(typ).
#21-030SMA BASEMENT PLAN 1/4" = 1'-0" UNEXCAVATED UP15 R2868WHFURNF.D.92% FUT. FAMILY/REC RM *UNFINISHED FUT. BDRM *UNFINISHED MECH/STORAGE *UNFINISHED11'-0"36'-0"15'-0"14'-0"7'-0"50'-0"22'-6"27'-6"6'-0"21'-6"20'-6"2'-0"47'-0"30'-0"17'-0"11'-0"19'-0"8'-0"14'-0"11'-0"50'-0"
8'-0"10'-8"7'-4"18'-0"
6'-6"
3'-8"3'-8"4'-4"5'-0"6'-6"30"x30"x12"CONC. PAD FTG.30"x30"x12"CONC. PAD FTG.18'-6"8'-4" POURED FOUNDATIONWALLEDGEWALLEDGE5'-8"15'-10"20x8 FTG.TRT. 4x4 CURB2x4 - 16" O.C.20x8 FTG.TRT. 4x4 CURB2x4 - 16" O.C.20x8 FTG.TRT. 4x6 CURB2x6 - 16" O.C.20x8 FTG.TRT. 4x6 CURB2x6 - 16" O.C.2-11 7/8" LSL FLUSH11 7/8" LSL
JOISTS 6x6 POSTSUMPRADONVENT6" CANT.2" LEDGESD/COLOOKOUT
LOOKOUT WALKOUTWALKOUTWALKOUT9068 P.D.50682668266830"4834NO FTG.@ TOILET2-2x10(2) TRT. 6x6 POSTON 12x16 PIER FTG.24x24 FROST FTG.9"7'-6"8'-9"TRT. 2-2x10 FLUSHTRT. 2-2x10 FLUSHTREATED
2x8
16" O.C.
11 7/8" LSL
JOISTS
11 7/8" LSL
JOISTS 3-2x106/0x5/0 SL7'-2"7'-10"7'-0"7'-0"HDR CONC. PATIO *14x106'-0"2-2x103-11 7/8" LVL DROPPED2868 STORAGE *UNFINISHED19'-0"1'-2"Structural Braced Wall Details Provided by:Becklin & Whitney Consulting Engineers, Inc139 1st Ave. E. Ste 200P.O. Box 471Cambridge, MN 55008763.689.5631Braced Wall Plan For:20177 Harvest DrWoodbury, MNHD1HD1HD1HD1Exterior Walls (Lower level) UNO:(1) 2x6" SPF #2 or better 16" O.C. w/ 7/16" OSB fastened to studs and plates w/ 8d nails 6" O.C. at all edges and 12" O.C. in the field. Sill plates fastened to concrete w/ 1/2" anchor bolts 4' O.C. and 1' fromall ends and openingsS1 of 4Braced Wall PlanI HEREBY CERTIFY THAT THIS PLAN, SPECIFICATION, OR REPORT WAS PREPARED BY ME OR UNDER MY DIRECT SUPERVISION AND THAT I AM A DULY REGISTERED PROFESSIONAL ENGINEER UNDER THE LAWS OF THE STATE OF MINNESOTA.WILLIAM A. BECKLIN, P.E. DATE: APRIL 28, 2021 LIC. NO. 18494
#21-030SMA FIRST FLOOR PLAN 1/4" = 1'-0" 1,123 SQ. FT.9' CEILING @ FIRST FLOOR WOOD PORCH 12x12 BOXED COL.ON 18"x18"x42"STONE BASE2-7 1/4" LSL4'-4"UP17 RDN15 R5'-10"GASF.P.PED 20682468DESK12" SH'S24682868FIREDOOR14'-6"13'-6"REF'G10" S.B.
30" RANGE30"PANT.2868 C.O.PANTRY*L.V.P.1/2 WALLW/ WD. CAP2-9 1/2" LVL9/0x5/0 SLCHASE3068
2/6x2/6 AWN2-2x10WALLEDGEWALLEDGE2/0x2/0 FX
2-2x10
2/0x2/0 FX
2-2x10
3/0x5/0 FX
TOP @ 6'-10"
2-2x102-2x104/0x4/0 SLREF'GRECESS9x8 OVH. DR.16x8 OVH. DR.*4" CONC. FLOOR GARAGE 2-2x10
2/0x2/0 FX
FOYER *L.V.P.*L.V.P. DINING *L.V.P. GREAT ROOM KITCHEN *L.V.P. MUD RM *L.V.P.*L.V.P.*L.V.P.*2x6 WALLS11'-0"36'-0"15'-0"14'-0"7'-0"3'-10"3'-2"7'-0"6'-4"8'-8"50'-0"22'-6"27'-6"6'-0"21'-6"20'-6"2'-0"
6'-0"4'-4"4'-10"6'-4"
3'-8"2'-8"47'-0"30'-0"17'-0"11'-0"19'-0"5'-11"5'-1"9'-6"9'-6"8'-9"7'-6"9"8'-0"14'-0"4'-7"8'-8"4'-3"11'-0"7'-4"11'-2"2'-2"4'-2"4'-10"6"2-2x103'-3"2'-9"
3'-3"
50'-0"
8'-0"
10'-8"7'-4"18'-0"
6'-2"4'-6"5'-10"6'-4"5'-10"
3'-2"2'-8"2'-8"3'-2"1'-8"RAILRAIL2'-10"6'-2"11'-4"3'-8"3'-8"4'-0"8'-0" CAB.
4'-0"2-7 1/4" LSL6'-6"
6'-0"6"7'-4"F21'-8"
18" FLR.TRUSS
19.2" O.C.
18" FLR.TRUSS
19.2" O.C.
GIRDER F.T.2-2x10FLUSH2-2x10 FLUSH24" CANT.12" CANT.36'-0"6'-0"RADONVENT2x6TRUSSES24" O.C.2-9 1/2" LSLFLUSH2-2x10GYP. BD.24" SH'S2468
3'-0" CAB.2-2x10
TOP @ 6'-10"TOP @ 6'-10"4"2'-6" W.I.C. *L.V.P.4"4"2-2x1017'-0"2x6SD/CO18" FLR.TRUSS
19.2" O.C.
GIRDER
2-9 1/2" LVL9/0x5/0 SLTOP @ 6'-10"3068FULLVIEWDECKLEDGER3'-0"Exterior Walls (Main level) UNO:(1) 2x6" SPF #2 or better 16" O.C. w/ 7/16" OSB fastened to studs and plates w/ 8d nails 6" O.C. at all edgesand 12" O.C. in the field. I HEREBY CERTIFY THAT THIS PLAN, SPECIFICATION, OR REPORT WAS PREPARED BY ME OR UNDER MY DIRECT SUPERVISION AND THAT I AM A DULY REGISTERED PROFESSIONAL ENGINEER UNDER THE LAWS OF THE STATE OF MINNESOTA.WILLIAM A. BECKLIN, P.E. DATE: APRIL 28, 2021 LIC. NO. 18494S3 of 4Structural Braced Wall Details Provided by:Becklin & Whitney Consulting Engineers, Inc139 1st Ave. E. Ste 200P.O. Box 471Cambridge, MN 55008763.689.5631Braced Wall PlanHD1Braced Wall Plan For:20177 Harvest DrWoodbury, MNHD1HD1HD2HD2Portal Frame per Figure 1w/ (2) 1.75x11.875" 1.9E LVLPortal Frame per Figure 2 w/ (2) 1.75x24" 2.0E LVL or (3) 1.75x20" LVLTruss blocking per Figure 3/S4Truss blocking per Figure 3/S4 required at cantilever.(1) 2x6" SPF #2 or better 16" O.C. w/ 1/2" (min) gypsum board fastened to studs/ plates w/ #9 screws 4" O.C. at all edges and 6" in the field.Truss blocking per Figure 3/S4.(1) 2x6" SPF #2 or better 16" O.C. w/7/16" OSB fastened to studs and plates w/ 8d nails 4" O.C. at all edges and 8" O.C. in the field. Block all seams solid. Sill plates fastened to concrete w/ 1/2" anchor bolts 4' O.C. and 1' fromall ends and openings
#21-030SMA SECOND FLOOR PLAN 1/4" = 1'-0" 1,236 SQ. FT.DN17 R5'-0" TUB
& SHOWER
1 PIECE FIB.66"246826685/0x6/0 FX TEMP5'-8"WD2468PKT.2668206826685068LIN.6/0x4/6 SL2-2x10*CARPET MASTER BEDROOM *CARPET BEDROOM #2 BEDROOM #3 *CARPET W.I.C. *CARPET2-2x107/6x5/0 SL2-2x106/0x5/0 SL36'-0"7'-0"14'-0"15'-0"7'-0"7'-0"8'-8"6'-4"12'-4"3'-0"7'-0"1'-10"3'-6"
41'-0"
38'-0"3'-0"
12'-4"5'-8"7'-4"12'-8"WALLEDGEWALLEDGE2-9 1/2" LSL
TOP @ 8'
OFF LNDG.36'-0"26'-0"10'-0"12'-0"14'-0"6'-0"6'-0"2'-6"11'-6"1'-0"
15'-0"
25'-0"
22'-0"3'-0"
8'-7"16'-0"
3'-8"3'-8"12'-8"4'-4"6'-8"4'-10"FF*VINYL*VINYLSD/COSDSDSD2x6GIRDERGIRDER @ 9' PLT. HT.ACCESS
ATTIC
3'-8"3'-8"1/2 WALLW/ WD. CAP10"TRUSSES
24" O.C.TRUSSES24" O.C.TRUSSES24" O.C.RADONVENT2x660342468 C.O.LT2868PKT.2468246824x24LIN.102"
5'-3"6'-5"3'-8"
2-2x10
2/0x2/6 AWN
2-2x102/6x4/0 SH5'-3"1'-9"*VINYL*VINYL1/2 WALLW/ WD. CAPWALLHUNG1 PIECE FIB.2-2x10
2/0x2/6 AWN
6'-8"2'-6"*9' CLG.6/0x4/0 SL2-2x102668SD506850687'-3"4'-3" BEDROOM #4 *CARPET12'-10"2'-2"4'-4"7'-10"7'-6"4'-2"2x69' WALL8' TALL 2x4 WALLW/ 1' TALL 2x6 WALLABOVE ROOF PLAN 1/8" = 1'-0" 1'-5"2'-0"1'-6"1'-6"1'-0"GIRDER @ 9'GIRDER1'-0"1'-6"1'-9"8128128128128128121272'-0"6/12RAISED HEEL4/12Exterior Walls (2nd level):(1) 2x6" SPF #2 or better 16" O.C. w/ 7/16" OSB fastened to studs andplates w/ 8d nails 6" O.C. at all edges and 12" O.C. in the field. I HEREBY CERTIFY THAT THIS PLAN, SPECIFICATION, OR REPORT WAS PREPARED BY ME OR UNDER MY DIRECT SUPERVISION AND THAT I AM A DULY REGISTERED PROFESSIONAL ENGINEER UNDER THE LAWS OF THE STATE OF MINNESOTA.WILLIAM A. BECKLIN, P.E. DATE: APRIL 28, 2021 LIC. NO. 18494S3 of 4Structural Braced Wall Details Provided by:Becklin & Whitney Consulting Engineers, Inc139 1st Ave. E. Ste 200P.O. Box 471Cambridge, MN 55008763.689.5631Braced Wall Plan For:20177 Harvest DrWoodbury, MNHD2HD2HD2 Braced Wall Plan
#21-030SMABlocking at sheathingseams716" OSBLSTA 49 fastened toinside of wall w/ 10d x1-1/2" nailsPlates fastened tobeam w/ (2) rows of10d x 3" nails 3" O.C.Figure 1: Portal FrameSection Fasten sheathing to LVLw/ 8d nails in a 3"x3" gridFasten sheathing to studs/ platesand blocking w/ 8d nails 3" O.C.1'-0" minSimpson LSTA 49 w/ 10d x1-1/2nails to inside face of wallSimpson HDU2-2.5 hold down w/(6) 14"x2-1/2" Simpson SDS screwsand (1) 58"x16" bent anchor rod.12"x14" bent anchor bolt w/2x2"x316" plate washer1'-3" minFasten sheathing to LVLw/ 8d nails in a 3"x3" gridFasten sheathing to studs/ platesand blocking w/ 8d nails 3" O.C.1'-6" minSimpson LSTA 49 w/ 10d x1-1/2nails to inside face of wallSimpson HDU2-2.5 hold down w/(6) 14"x2-1/2" Simpson SDS screwsand (1) 58"x16" bent anchor rod.Blocking at sheathingseams716" OSBLSTA 49 fastened toinside of wall w/ 10d x1-1/2" nailsPlates fastened tobeam w/ (2) rows of10d x 3" nails 3" O.C.Figure 2: Portal FrameSection 12"x14" bent anchor bolt w/2x2"x316" plate washer1'-6" minFloor truss
Floor truss Fasten shear panels to trussesw/ (4) 16d nails on each sideFasten 716" OSB to all2x w/ 8d nails 3" O.C.Figure 3:Shear Blocking Detail2x4"(2) 2x4"2x4"
2x4"Preservative-treated barrier may berequiredPost size byDesignerMinimum woodmember thicknessC
le
a
r s
p
a
n (2) 2x6" (min)(3) 1.75x20" 1.9E LVL (min) S4 of 4HD1:HDU4-SDS2.5 hold down w/ (10)1.4"x2 1/2" SDS screws and w/ 5/8"x14" bent anchor boltHD2:MSTC40 w/ 10d nailsI HEREBY CERTIFY THAT THIS PLAN, SPECIFICATION, OR REPORT WAS PREPARED BY ME OR UNDER MY DIRECT SUPERVISION AND THAT I AM A DULY REGISTERED PROFESSIONAL ENGINEER UNDER THE LAWS OF THE STATE OF MINNESOTA.WILLIAM A. BECKLIN, P.E. DATE: APRIL 28, 2021 LIC. NO. 18494Braced Wall Plan For:20177 Harvest DrWoodbury, MNStructural Braced Wall Details Provided by:Becklin & Whitney Consulting Engineers, Inc139 1st Ave. E. Ste 200P.O. Box 471Cambridge, MN 55008763.689.5631Braced Wall Plan*All hardware is manufactured by Simpson Strong Tie.
Stone Cottage
HVAC Load Calculations
for
Meester
20177 Harvest Dr
Lakeville,mn
Prepared By:
Randy Andrews
Lofgren Heating
5708 Upper 147th Street West
Apple Vallley, MN 55124
Thursday, March 18, 2021
Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc.
Lofgren Htg. & A/C Stone Cottage
Farmington, MN 55024 Page 2
Project Report
General Project Information
Project Title:Stone Cottage
Project Date:Thursday, March 18, 2021
Client Name:Meester
Client Address:20177 Harvest Dr
Client City:Lakeville,mn
Company Name:Lofgren Heating
Company Representative:Randy Andrews
Company Address:5708 Upper 147th Street West
Company City:Apple Vallley, MN 55124
Company E-Mail Address:rrandrews@lofgrenheating-ac.com
Design Data
Reference City:Minneapolis, Minnesota
Building Orientation:Front door faces North
Daily Temperature Range:Medium
Latitude:44 Degrees
Elevation:834 ft.
Altitude Factor:0.970
Elevation Sensible Adj. Factor:1.000
Elevation Total Adj. Factor:1.000
Elevation Heating Adj. Factor:1.000
Elevation Heating Adj. Factor:1.000
Outdoor Outdoor Outdoor Indoor Indoor Grains
Dry Bulb Wet Bulb Rel.Hum Rel.Hum Dry Bulb Difference
Winter:-15 -15.33 80%n/a 72 n/a
Summer:88 72 47%50%75 29
Check Figures
Total Building Supply CFM:1,142 CFM Per Square ft.:0.328
Square ft. of Room Area:3,482 Square ft. Per Ton:1,268
Volume (ft³) of Cond. Space:31,338
Building Loads
Total Heating Required Including Ventilation Air:52,483 Btuh 52.483 MBH
Total Sensible Gain:24,721 Btuh 79 %
Total Latent Gain:6,639 Btuh 21 %
Total Cooling Required Including Ventilation Air:31,360 Btuh 2.61 Tons (Based On Sensible + Latent)
2.75 Tons (Based On 75% Sensible
Capacity)
Notes
Calculations are based on 8th edition of ACCA Manual J.
All computed results are estimates as building use and weather may vary.
Be sure to select a unit that meets both sensible and latent loads.
C:\ ...\20177 HARVEST LAKEVILLE 03182021.rhv Thursday, March 18, 2021, 9:53 AM
Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc.
Lofgren Htg. & A/C Stone Cottage
Farmington, MN 55024 Page 3
Load Preview Report
Scope
Has
AED
Net
Ton
ft.²
/Ton Area
Sen
Gain
Lat
Gain
Net
Gain
Sen
Loss
Sys
Htg
CFM
Sys
Clg
CFM
Sys
Act
CFM
Duct
Size
Building 2.61 1,332 3,482 24,721 6,639 31,360 52,483 998 1,142 1,142
System 1 Yes 2.61 1,332 3,482 24,721 6,639 31,360 52,483 998 1,142 1,142 21x10
Ventilation 340 1,352 1,692 4,550
Zone 1 3,482 24,381 5,287 29,668 47,933 998 1,142 1,142 21x10
1-Main Level 1,123 9,769 1,845 11,614 17,848 372 458 458 5--6
2-Upper Level 1,236 11,479 2,439 13,918 18,661 389 538 538 6--6
3-Lower Level 1,123 3,133 1,003 4,136 11,424 238 147 147 2--6
C:\ ...\20177 HARVEST LAKEVILLE 03182021.rhv Thursday, March 18, 2021, 9:53 AM
Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc.
Lofgren Htg. & A/C Stone Cottage
Farmington, MN 55024 Page 4
Total Building Summary Loads
Component
Description
Area
Quan
Sen
Loss
Lat
Gain
Sen
Gain
Total
Gain
4A-1a-o: Glazing-Double pane low-e (e = 0.20 or less),
operable window, e=0.20 on surface 2, wood with
metal clad frame, u-value 0.32, SHGC 0.33
471 13,112 0 10,656 10,656
11N: Door-Metal - Polystyrene Core 63 1,918 0 529 529
12F-0sw: Wall-Frame, R-21 insulation in 2 x 6 stud
cavity, no board insulation, siding finish, wood studs
2580 14,590 0 2,231 2,231
15B0-10sf-10: Wall-Basement, , R-10 board insulation to
floor, no interior finish, 10' floor depth
1080 4,603 0 0 0
16B-50: Roof/Ceiling-Under Attic with Insulation on Attic
Floor (also use for Knee Walls and Partition
Ceilings), Vented Attic, No Radiant Barrier, Dark
Asphalt Shingles or Dark Metal, Tar and Gravel or
Membrane, R-50 insulation
1236 2,151 0 1,187 1,187
21A-24: Floor-Basement, Concrete slab, any thickness, 2
or more feet below grade, no insulation below floor,
any floor cover, shortest side of floor slab is 24' wide
1123 2,443 0 0 0
Subtotals for structure:38,817 0 14,603 14,603
People:9 1,800 2,070 3,870
Equipment:2,500 7,000 9,500
Lighting:0 0 0
Ductwork:0 0 0 0
Infiltration: Winter CFM: 98, Summer CFM: 51 9,116 987 708 1,695
Ventilation: Winter CFM: 140, Summer CFM: 70 4,550 1,352 340 1,692
Total Building Load Totals:52,483 6,639 24,721 31,360
Check Figures
Total Building Supply CFM:1,142 CFM Per Square ft.:0.328
Square ft. of Room Area:3,482 Square ft. Per Ton:1,268
Volume (ft³) of Cond. Space:31,338
Building Loads
Total Heating Required Including Ventilation Air:52,483 Btuh 52.483 MBH
Total Sensible Gain:24,721 Btuh 79 %
Total Latent Gain:6,639 Btuh 21 %
Total Cooling Required Including Ventilation Air:31,360 Btuh 2.61 Tons (Based On Sensible + Latent)
2.75 Tons (Based On 75% Sensible
Capacity)
Notes
Calculations are based on 8th edition of ACCA Manual J.
All computed results are estimates as building use and weather may vary.
Be sure to select a unit that meets both sensible and latent loads.
C:\ ...\20177 HARVEST LAKEVILLE 03182021.rhv Thursday, March 18, 2021, 9:53 AM
Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc.
Lofgren Htg. & A/C Stone Cottage
Farmington, MN 55024 Page 5
Building Pie Chart
Building
Loss
52,483
Btuh
Floor 5%Roof 4%
Wall 37%
Glass 25%
Door 4%
Infiltration 17%
Ventilation 9%
Building
Gain
31,360
Btuh
Roof 4%Wall 7%
Glass 34%
Door 2%People 12%
Equipment 30%
Infiltration 5%
Ventilation 5%
C:\ ...\20177 HARVEST LAKEVILLE 03182021.rhv Thursday, March 18, 2021, 9:53 AM
Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc.
Lofgren Htg. & A/C Stone Cottage
Farmington, MN 55024 Page 6
System 1 Whole House Summary Loads
Component
Description
Area
Quan
Sen
Loss
Lat
Gain
Sen
Gain
Total
Gain
4A-1a-o: Glazing-Double pane low-e (e = 0.20 or less),
operable window, e=0.20 on surface 2, wood with
metal clad frame, u-value 0.32, SHGC 0.33
471 13,112 0 10,656 10,656
11N: Door-Metal - Polystyrene Core 63 1,918 0 529 529
12F-0sw: Wall-Frame, R-21 insulation in 2 x 6 stud
cavity, no board insulation, siding finish, wood studs
2580 14,590 0 2,231 2,231
15B0-10sf-10: Wall-Basement, , R-10 board insulation to
floor, no interior finish, 10' floor depth
1080 4,603 0 0 0
16B-50: Roof/Ceiling-Under Attic with Insulation on Attic
Floor (also use for Knee Walls and Partition
Ceilings), Vented Attic, No Radiant Barrier, Dark
Asphalt Shingles or Dark Metal, Tar and Gravel or
Membrane, R-50 insulation
1236 2,151 0 1,187 1,187
21A-24: Floor-Basement, Concrete slab, any thickness, 2
or more feet below grade, no insulation below floor,
any floor cover, shortest side of floor slab is 24' wide
1123 2,443 0 0 0
Subtotals for structure:38,817 0 14,603 14,603
People:9 1,800 2,070 3,870
Equipment:2,500 7,000 9,500
Lighting:0 0 0
Ductwork:0 0 0 0
Infiltration: Winter CFM: 98, Summer CFM: 51 9,116 987 708 1,695
Ventilation: Winter CFM: 140, Summer CFM: 70 4,550 1,352 340 1,692
System 1 Whole House Load Totals:52,483 6,639 24,721 31,360
Check Figures
Supply CFM:1,142 CFM Per Square ft.:0.328
Square ft. of Room Area:3,482 Square ft. Per Ton:1,268
Volume (ft³) of Cond. Space:31,338
System Loads
Total Heating Required Including Ventilation Air:52,483 Btuh 52.483 MBH
Total Sensible Gain:24,721 Btuh 79 %
Total Latent Gain:6,639 Btuh 21 %
Total Cooling Required Including Ventilation Air:31,360 Btuh 2.61 Tons (Based On Sensible + Latent)
2.75 Tons (Based On 75% Sensible
Capacity)
Notes
Calculations are based on 8th edition of ACCA Manual J.
All computed results are estimates as building use and weather may vary.
Be sure to select a unit that meets both sensible and latent loads.
C:\ ...\20177 HARVEST LAKEVILLE 03182021.rhv Thursday, March 18, 2021, 9:53 AM
Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc.
Lofgren Htg. & A/C Stone Cottage
Farmington, MN 55024 Page 7
Detailed Room Loads - Room 1 - Main Level (Average Load Procedure)
General
Calculation Mode:Htg. & clg.Occurrences:1
Room Length:1,123.0 ft.System Number:1
Room Width:1.0 ft.Zone Number:1
Area:1,123.0 sq.ft.Supply Air:458 CFM
Ceiling Height:9.0 ft.Supply Air Changes:2.7 AC/hr
Volume:10,107.0 cu.ft.Req. Vent. Clg:0 CFM
Number of Registers:5 Actual Winter Vent.:52 CFM
Runout Air:92 CFM Percent of Supply.:11 %
Runout Duct Size:6 in.Actual Summer Vent.:28 CFM
Runout Air Velocity:466 ft./min.Percent of Supply:6 %
Runout Air Velocity:466 ft./min.Actual Winter Infil.:44 CFM
Actual Loss:0.136 in.wg./100 ft.Actual Summer Infil.:23 CFM
Item
Description
Area
Quantity
-U-
Value
Htg
HTM
Sen
Loss
Clg
HTM
Lat
Gain
Sen
Gain
S -Wall-12F-0sw 36 X 9 218 0.065 5.7 1,233 0.9 0 188
N -Wall-12F-0sw 36 X 9 239 0.065 5.7 1,352 0.9 0 207
E -Wall-12F-0sw 42 X 9 358 0.065 5.7 2,024 0.9 0 309
W -Wall-12F-0sw 42 X 9 335 0.065 5.7 1,894 0.9 0 290
N -Door-11N 6 X 7 42 0.350 30.5 1,279 8.4 0 353
N -Door-11N 3 X 7 21 0.350 30.5 639 8.4 0 176
S -Gls-4A-1a-o shgc-0.33 0%S 106 0.320 27.8 2,951 19.2 0 2,033
N -Gls-4A-1a-o shgc-0.33 100%S 22 0.320 27.8 612 10.4 0 229
E -Gls-4A-1a-o shgc-0.33 0%S 20 0.320 27.8 557 35.0 0 700
W -Gls-4A-1a-o shgc-0.33 0%S 43 0.320 27.8 1,197 35.0 0 1,505
Subtotals for Structure:13,738 0 5,990
Infil.: Win.: 44.3, Sum.: 23.0 1,404 2.927 4,110 0.227 445 319
People: 200 lat/per, 230 sen/per:2 400 460
Equipment:1,000 3,000
Room Totals:17,848 1,845 9,769
C:\ ...\20177 HARVEST LAKEVILLE 03182021.rhv Thursday, March 18, 2021, 9:53 AM
Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc.
Lofgren Htg. & A/C Stone Cottage
Farmington, MN 55024 Page 8
Detailed Room Loads - Room 2 - Upper Level (Average Load Procedure)
General
Calculation Mode:Htg. & clg.Occurrences:1
Room Length:1,236.0 ft.System Number:1
Room Width:1.0 ft.Zone Number:1
Area:1,236.0 sq.ft.Supply Air:538 CFM
Ceiling Height:9.0 ft.Supply Air Changes:2.9 AC/hr
Volume:11,124.0 cu.ft.Req. Vent. Clg:0 CFM
Number of Registers:6 Actual Winter Vent.:55 CFM
Runout Air:90 CFM Percent of Supply.:10 %
Runout Duct Size:6 in.Actual Summer Vent.:33 CFM
Runout Air Velocity:456 ft./min.Percent of Supply:6 %
Runout Air Velocity:456 ft./min.Actual Winter Infil.:44 CFM
Actual Loss:0.130 in.wg./100 ft.Actual Summer Infil.:23 CFM
Item
Description
Area
Quantity
-U-
Value
Htg
HTM
Sen
Loss
Clg
HTM
Lat
Gain
Sen
Gain
S -Wall-12F-0sw 36 X 9 247 0.065 5.7 1,397 0.9 0 214
N -Wall-12F-0sw 36 X 9 273 0.065 5.7 1,544 0.9 0 236
E -Wall-12F-0sw 41 X 9 319 0.065 5.7 1,804 0.9 0 276
W -Wall-12F-0sw 41 X 9 339 0.065 5.7 1,917 0.9 0 293
S -Gls-4A-1a-o shgc-0.33 0%S 77 0.320 27.8 2,144 19.2 0 1,477
N -Gls-4A-1a-o shgc-0.33 100%S 51 0.320 27.8 1,420 10.4 0 531
E -Gls-4A-1a-o shgc-0.33 0%S 50 0.320 27.8 1,392 35.0 0 1,750
W -Gls-4A-1a-o shgc-0.33 0%S 30 0.320 27.8 835 35.0 0 1,050
UP-Ceil-16B-50 1236 X 1 1236 0.020 1.7 2,151 1.0 0 1,187
Subtotals for Structure:14,604 0 7,014
Infil.: Win.: 43.7, Sum.: 22.7 1,386 2.927 4,057 0.227 439 315
People: 200 lat/per, 230 sen/per:5 1,000 1,150
Equipment:1,000 3,000
Room Totals:18,661 2,439 11,479
C:\ ...\20177 HARVEST LAKEVILLE 03182021.rhv Thursday, March 18, 2021, 9:53 AM
Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc.
Lofgren Htg. & A/C Stone Cottage
Farmington, MN 55024 Page 9
Detailed Room Loads - Room 3 - Lower Level (Average Load Procedure)
General
Calculation Mode:Htg. & clg.Occurrences:1
Room Length:1,123.0 ft.System Number:1
Room Width:1.0 ft.Zone Number:1
Area:1,123.0 sq.ft.Supply Air:147 CFM
Ceiling Height:9.0 ft.Supply Air Changes:0.9 AC/hr
Volume:10,107.0 cu.ft.Req. Vent. Clg:0 CFM
Number of Registers:2 Actual Winter Vent.:33 CFM
Runout Air:73 CFM Percent of Supply.:23 %
Runout Duct Size:6 in.Actual Summer Vent.:9 CFM
Runout Air Velocity:374 ft./min.Percent of Supply:6 %
Runout Air Velocity:374 ft./min.Actual Winter Infil.:10 CFM
Actual Loss:0.088 in.wg./100 ft.Actual Summer Infil.:5 CFM
Item
Description
Area
Quantity
-U-
Value
Htg
HTM
Sen
Loss
Clg
HTM
Lat
Gain
Sen
Gain
S -Wall-12F-0sw 36 X 9 252 0.065 5.7 1,425 0.9 0 218
N -Wall-15B0-10sf-10 36 X 9 324 0.049 4.3 1,381 0.0 0 0
E -Wall-15B0-10sf-10 42 X 9 378 0.049 4.3 1,611 0.0 0 0
W -Wall-15B0-10sf-10 42 X 9 378 0.049 4.3 1,611 0.0 0 0
S -Gls-4A-1a-o shgc-0.33 0%S 72 0.320 27.8 2,004 19.2 0 1,381
Floor-21A-24 1 X 1123 1123 0.025 2.2 2,443 0.0 0 0
Subtotals for Structure:10,475 0 1,599
Infil.: Win.: 10.2, Sum.: 5.3 324 2.929 949 0.228 103 74
People: 200 lat/per, 230 sen/per:2 400 460
Equipment:500 1,000
Room Totals:11,424 1,003 3,133
C:\ ...\20177 HARVEST LAKEVILLE 03182021.rhv Thursday, March 18, 2021, 9:53 AM
Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc.
Lofgren Htg. & A/C Stone Cottage
Farmington, MN 55024 Page 10
System 1 Room Load Summary
No
Room
Name
Area
SF
Htg
Sens
Btuh
Min
Htg
CFM
Run
Duct
Size
Run
Duct
Vel
Clg
Sens
Btuh
Clg
Lat
Btuh
Min
Clg
CFM
Act
Sys
CFM
---Zone 1---
1 Main Level 1,123 17,848 372 5-6 466 9,769 1,845 458 458
2 Upper Level 1,236 18,661 389 6-6 456 11,479 2,439 538 538
3 Lower Level 1,123 11,424 238 2-6 374 3,133 1,003 147 147
Ventilation 4,550 340 1,352
System 1 total 3,482 52,483 998 24,721 6,639 1,142 1,142
System 1 Main Trunk Size:21x10 in.
Velocity:783 ft./min
Loss per 100 ft.:0.091 in.wg
Cooling System Summary
Cooling
Tons
Sensible/Latent
Split
Sensible
Btuh
Latent
Btuh
Total
Btuh
Net Required:2.61 79% / 21%24,721 6,639 31,360
Recommended:2.75 75% / 25%24,721 8,240 32,961
Actual:1.00 77% / 23%9,240 2,760 12,000
Equipment Data
Heating System Cooling System
Type:Natural Gas Furnace Standard Air Conditioner
Model:QC-F38-E78-G QC-C12
Indoor Model:S12
Brand:Quikcool FE Series Quikcool AS Series
Description:Hi Efficiency Furnace Standard Efficiency Air Condit
Efficiency:78.3 AFUE 12.4 SEER
Sound:8.1 bels
Capacity:38,000 Btuh 12,000 Btuh
Sensible Capacity:n/a 9,240 Btuh
Latent Capacity:n/a 2,760 Btuh
C:\ ...\20177 HARVEST LAKEVILLE 03182021.rhv Thursday, March 18, 2021, 9:53 AM
Builders Associaton of Minnesota version 101014
Date Certificate Posted
x Passive (No Fan)
Active (With fan and monometer
or other system monitoring
Location (or future location) of Fan:
Other Please Describe Here
x
10/15 x x
x
20 x
20 x
21 x
49 x
x
x
x
x Not applicable, all ducts located in conditioned space
x Not required per mech. code
Passive
Powered
Interlocked with exhaust device.
Describe:Input in
BTUS:
70,000 Capacity in
Gallons:
Other, describe:
AFUE or
HSPF%
93%
Cfm's
" round duct OR
" metal duct
Not required per mech. code
x Passive
Low: Other, describe:
x Low:
Location of fan(s), describe: Cfm's
4" " round duct OR Flex
" metal duct
ML193UH070
Heating Loss
Manufacturer Lennox
Natural Gas
Output in
Tons:
3 Ton50
Total ventilation (intermittent + continuous) rate in cfms:
Balanced Ventilation capacity in cfms:
High:
High:
MECHANICAL VENTILATION SYSTEM
Capacity continuous ventilation rate in cfms:
200CFM
Select Type
Describe any additional or combined heating or cooling systems if installed: (e.g. two furnaces or air
source heat pump with gas back-up furnace):
24,721Residential Load Calculation
SEER
/EER
Location of duct or system:
Heating or Cooling Ducts Outside Conditioned Spaces
Electric
Make-up Air Select a Type
AO Smith
Domestic Water
Heater
MECHANICAL SYSTEMS
Rating or Size
Efficiency 13 Seer
Building envelope air tightness:
Rim Joist (1st Floor)
GPVL-50 13ACXN042-230 Model
Heating System
Natrual Gas
Lennox Fiberglass, Batts Foundation Wall
R-value
Average U-Factor (excludes skylights and one door) U:
Duct system air tightness:
Cooling SystemTotal R-Value of all Types of InsulationType: Check All That Apply
Mineral Fiberboard Insulation Location
Foam, Closed Cell0.22
Describe other insulated areas Fiberglass, BlownTHERMAL ENVELOPE
Foam Open Cell Wall Rigid, Isocynurate Perimeter of Slab on Grade
RADON CONTROL SYSTEM
Non or Not ApplicableAttic
Fuel Type
Solar Heat Gain Coefficient (SHGC):
Windows & Doors
Ceiling, vaulted
Bay Windows or cantilevered areas
Floors over unconditioned area
Rim Joist (2nd Floor+)
0.30
Appliances
Mech Room
Heat Recover Ventilator (HRV) Capacity in cfms:
Energy Recover Ventilator (ERV) Capacity in cfms:
52,483
Heating Gain Cooling Load
Per R401.3 Certificate. A building certificate shall be posted on or in the electrical distribution panel.
Place your
logo here
New Construction Energy Code Compliance Certificate
Name of Residential Contractor
Stone Cottage Construction Inc.
MN License Number
Lakeville20177 Harvest Dr
BC636874
City Mailing Address of the Dwelling or Dwelling Unit
Combustion Air Select a Type
Location of duct or system:
31,360
Below Entire Slab Rigid, Extruded Polystyrene Ceiling, flat
NEW RESIDENTIAL CONSTRUCTION SWPPP VERIFICATION
This form must be completed and submitted with all new residential permit applications.
New residential building permits WILL NOT be issued without this completed form.
Project Site Address: _____________________________________________________________________
Company Name: _________________________________________________________________________
Primary Contact: _________________________________________________________________________
Phone # (24 hr Contact): ______________________ Email: ______________________________________
Description of Land Disturbing Activity: _____________________________________________________
NPDES Construction Stormwater Permit # C000 ___ ___ ___ ___ ___ or # SUB00 ___ ___ ___ ___ ___
If you are not covered under a NPDES Construction Stormwater Permit administered by the MPCA, an
erosion and sediment control plan MUST be submitted with the residential building permit application.
“The permittee(s) shall ensure that the individuals are trained by local, state, federal agencies, professional organizations or other entities
in erosion prevention, sediment control, permanent Stormwater management and the Minnesota NPDES/SDS Construction Stormwater
Permit.” (NPDES Construction Stormwater Permit, MPCA)
“The permittee(s) must ensure that a trained person (as identified in Part III.A.3.a) will routinely inspect the entire construction site at least
once every seven (7) days during active construction and within 24 hours after a rainfall event greater than 0.5 inches in 24 hours.”
(NPDES Construction Stormwater Permit, MPCA)
Contact information of person CERTIFIED to provide weekly onsite erosion and sediment control
inspections and corrective actions:
Name of Person: ________________________________Company: _______________________________
Phone # (24 hr Contact): ______________________ Email: ______________________________________
Entity that Provided Training: ________________________ Certification Expiration Date: ____________
NOTE: Prior to any land-disturbing activity, all erosion and sediment controls must be installed on the project site and on individual lots.
No land disturbing activity may begin until a residential building permit has been issued.
I understand, the above information to be true and I will have read, understood, and accepted all terms and conditions of the National
Pollutant Discharge Elimination System (NPDES) Permit (MN R 100001). The City of Lakeville may issue a STOP WORK ORDER;
withhold building inspections; or, draw on securities/escrows to bring the site into compliance with the NPDES Construction Stormwater
Permit (MN R 100001) or erosion and sediment control plan.
Signature: ________________________________________________ Date:_________________________
Contact the City of Lakeville with questions at erosion@lakevillemn.gov or 952-985-4500
04/20/21
KP
X