Loading...
HomeMy WebLinkAboutLA193840 - 718 Romeo Dr Permit Pack4/14/21 DM OFFICE USE ONLY MANUFACTURED HOME PERMIT APPLICATION USE AND OCCUPANCY: _____ _____ _____ _____ REQUIRED INSPECTIONS: FOOTING TIE-DOWNS AND BLOCKING BUILDING FINAL (copy of Systems Test Affidavit) PERMIT FEE: PERMIT FEE: $____________________ SURCHARGE: $____________________ TOTAL: $____________________ BUILDING INSPECTOR: __________________________ DATE:__________________________ COMMENTS: BUILDING CODE CONSTRUCTION TYPE IRC DWELLING TYPE ZONING Site Address: Driveway Street:Notes: No Gas 710 Electric H2O 34’48’ 21’ 22’ Sewer 40’724 16x66 718 Juliet Dr Min 20' to edge of street Min 20' between trailers Project Number:PA-5428 Project Address: Revision:3 References: Lakeshore 6616-722 8ft Spread.pdf Date:2021-08-13 Designed by:S.H. Reviewed by:N/A Issued for:Quote Project Type:Manufactured Home Manufacturer:Clayton A- PILE LIST Dimension Roof pitch Wall height wind zone Roof Snow (psf) 15'-4"x66'3/12 8'1 30 Pile ID # of piles Max pile spacing Pile Diameter Wall Thickness Min Installation Torque Min embedded depth *Note 1.2 Min total length of pile Max height above ground Bracing Pile cap/head ft in in lb-ft ft ft in HP-1 6 9 2 7/8 0.250 1,800 7.0 10 36 Yes GTTOPIBEAMBR HP-2 10 9 2 3/8 0.250 1,700 7.0 10 36 No GTTOPIBEAM B- REMARKS 1. General Notes 1.1 The Pile location is assumed as shown on sketch (Section D). 1.2 The minimum embedded depth of the pile is equal to the highest value of: a. Depth to reach the required torque; b. Below the frost line; c. 5 times the upper helix diameter d. Minimum ambedded depth for lateral resistance 1.3 The minimum distance between the piles equals the greater of: 3' or 3x the maximum helix diameter. 1.4 Safety factor = 2 2. Loads 2.1 Axial loads are based on the given configuration and location using the applicable loads according to approriate building code. 2.2 Lateral loads calculated based on the configuration and location of the project. 3. Soil Conditions 3.1 No soil report (Geotechnical report) available 3.2 Pile test is required 3.3 Soil characteristics: a. The soil is assumed to be flat, firm and provide lateral support for the helical piles; Water Table is assumed below the helices This answer sheet and its calculations are only valid for Goliathtech piles. 1/2 7,911 lbs capacity required from manual Concept Approval ONLYSubject to Field Inspection Inspector Date 2020 MN Bldg Code 08/16/2021dmathews b. The soil is assumed to be non-liquefiable, non-expansive and non-compressible; c. Soil type is considered Cohesionless; d. Soil dentity :100 pcf e. Friction angle ϕ :30 (water table not considered) 4. Helices 4.1 The helices must be placed in an undisturbed soil. 4.2 The first(upper) helix must be located below any fill material 5. Braces 5.1 Braces pile position is shown in the drawing, starting from the second axis. 5.2 The braced pile's installation is not less than 3'' from the home's closest lateral beam 5.3 Pile installation as per the manufacturer's manual 5.7 Fastener components must be free from dirt and moisture. C- PILE LOCATION 4.3 Due to the absence of the geotechnical report to calculate the depth, size and number of helices, the piles capacity is to be verified through the installation torque method. 5.4 The pile number was determined using an overhang of the value of 12'' on each side of the beams. In the case of larger overhang, it needs to be re-calculated for possible additional uplift forces. 5.5 For the braced pile heads, 3/4'' Gr. 5 (A325) bolts should be torqued to 70% of its ternsile strength to form a slip-critical connection, otherwise, the design is invalid and connection is unstable. 5.6 The galvanised faying surfaces that are part of the pretension connections, including the underneath part of the home's H- beam, must be roughened and free from dust, oil, dirt, grease and rust. 8'-312" 3'-614" 3'-614" 2'-0" 62'-0" 2'-0" 66'-0" 15'-4"HP2 HP2 HP1 HP1 HP2 HP2 Lakeshore 6616-722 8ft Spread HP2 HP2 HP1 HP1 HP2 HP2 HP1 HP1 HP2 HP2 GTBRACEMB-7-9FT GTBRACEMB-7-9FTGTBRACEMB-7-9FT 8'-1014" 8'-1014" 8'-1014" 8'-1014" 8'-1014" 8'-1014" 8'-1014" This answer sheet and its calculations are only valid for Goliathtech piles. 2/2