MANUFACTURED HOME PERMIT APPLICATION
USE AND OCCUPANCY:
_____
_____
_____
_____
REQUIRED INSPECTIONS:
FOOTING
TIE-DOWNS AND BLOCKING
BUILDING FINAL (copy of Systems Test Affidavit)
PERMIT FEE:
PERMIT FEE: $____________________
SURCHARGE: $____________________
TOTAL: $____________________
BUILDING INSPECTOR: __________________________ DATE:__________________________
COMMENTS:
BUILDING CODE
CONSTRUCTION TYPE
IRC DWELLING TYPE
ZONING
Site Address:
Driveway
Street:Notes: No Gas
710
Electric
H2O
34’48’
21’
22’
Sewer
40’724
16x66
718 Juliet Dr
Min 20' to edge of street
Min 20' between trailers
Project Number:PA-5428 Project Address:
Revision:3 References: Lakeshore 6616-722 8ft Spread.pdf
Date:2021-08-13
Designed by:S.H.
Reviewed by:N/A
Issued for:Quote
Project Type:Manufactured Home
Manufacturer:Clayton
A- PILE LIST
Dimension Roof pitch Wall height wind zone Roof Snow
(psf)
15'-4"x66'3/12 8'1 30
Pile ID # of piles Max pile
spacing
Pile
Diameter
Wall
Thickness
Min
Installation
Torque
Min
embedded
depth
*Note 1.2
Min total
length of
pile
Max
height
above
ground
Bracing Pile cap/head
ft in in lb-ft ft ft in
HP-1 6 9 2 7/8 0.250 1,800 7.0 10 36 Yes GTTOPIBEAMBR
HP-2 10 9 2 3/8 0.250 1,700 7.0 10 36 No GTTOPIBEAM
B- REMARKS
1. General Notes
1.1 The Pile location is assumed as shown on sketch (Section D).
1.2 The minimum embedded depth of the pile is equal to the highest value of:
a. Depth to reach the required torque;
b. Below the frost line;
c. 5 times the upper helix diameter
d. Minimum ambedded depth for lateral resistance
1.3 The minimum distance between the piles equals the greater of: 3' or 3x the maximum helix diameter.
1.4 Safety factor = 2
2. Loads
2.1 Axial loads are based on the given configuration and location using the applicable loads according to approriate building code.
2.2 Lateral loads calculated based on the configuration and location of the project.
3. Soil Conditions
3.1 No soil report (Geotechnical report) available
3.2 Pile test is required
3.3 Soil characteristics:
a. The soil is assumed to be flat, firm and provide lateral support for the helical piles; Water Table is assumed below the helices
This answer sheet and its calculations are only valid for Goliathtech piles.
1/2
7,911 lbs capacity
required from manual
Concept Approval ONLYSubject to Field Inspection
Inspector Date
2020
MN Bldg
Code
08/16/2021dmathews
b. The soil is assumed to be non-liquefiable, non-expansive and non-compressible;
c. Soil type is considered Cohesionless;
d. Soil dentity :100 pcf
e. Friction angle ϕ :30 (water table not considered)
4. Helices
4.1 The helices must be placed in an undisturbed soil.
4.2 The first(upper) helix must be located below any fill material
5. Braces
5.1 Braces pile position is shown in the drawing, starting from the second axis.
5.2 The braced pile's installation is not less than 3'' from the home's closest lateral beam
5.3 Pile installation as per the manufacturer's manual
5.7 Fastener components must be free from dirt and moisture.
C- PILE LOCATION
4.3 Due to the absence of the geotechnical report to calculate the depth, size and number of
helices, the piles capacity is to be verified through the installation torque method.
5.4 The pile number was determined using an overhang of the value of 12'' on each side of the beams. In the case of larger
overhang, it needs to be re-calculated for possible additional uplift forces.
5.5 For the braced pile heads, 3/4'' Gr. 5 (A325) bolts should be torqued to 70% of its ternsile strength to form a slip-critical
connection, otherwise, the design is invalid and connection is unstable.
5.6 The galvanised faying surfaces that are part of the pretension connections, including the underneath part of the home's H-
beam, must be roughened and free from dust, oil, dirt, grease and rust. 8'-312" 3'-614" 3'-614" 2'-0" 62'-0" 2'-0"
66'-0" 15'-4"HP2
HP2
HP1
HP1
HP2
HP2
Lakeshore 6616-722 8ft Spread
HP2
HP2
HP1
HP1
HP2
HP2
HP1
HP1
HP2
HP2
GTBRACEMB-7-9FT GTBRACEMB-7-9FTGTBRACEMB-7-9FT
8'-1014" 8'-1014" 8'-1014" 8'-1014" 8'-1014" 8'-1014" 8'-1014"
This answer sheet and its calculations are only valid for Goliathtech piles.