Loading...
HomeMy WebLinkAboutLA179796 Plans421+6+817=12441250 max allowed forlot more than 1 acre.(2)11-7/8 LVL header forportal frame required depth.step to maintain minimum42" frost depth if needed.Concept Approval ONLYSubject to Field InspectionInspectorDate2015MN BldgCode05/19/2020dmathews assumed garagefooting depthExisting HouseExisting Garageassumed garagefooting depthExisting GarageExisting HouseGarage Addition for Bryce Austin 18268 Java Trail Lakeville, Mn. 55044A2 Date:5-12-20 gk DESIGN new and remodeled home design and drafting services Gene Klatt ph:(612)986-2262 e-mail: klattgr1@gmail.comsheet1A2EAST (BACK) ELEVATION 316"=1'-0"2A2NORTH (SIDE) ELEVATION 316"=1'-0"3A2WEST (FRONT) ELEVATION 316"=1'-0"Minimum requirementfor garage dooropening framing basedon provided size ofpanels on either sideof door opening. see plan for all header and beam sizesspray foam around all windows, doors andpenetrationsprovide 2x6 blocking for O.H. door -3 sideswindows to match overhead door heighthouse floor6 B.C. = 4'11'-6" plate hgt.914" heel 1' O.H.8"1'-4"8' overhead door existing garage ceiling/back wall5.5 B.C. = 3'-8"8"3'-10" 914" heel 18'-434"Typical Roof Construction:-cedar shake shingles (match existing)-15lb felt underlayment-"ice shield" at all roof edges and valley's-12" O.S.B. roof sheathing-"scissor" roof trusses @ 24" O.C.-1" air chute each truss spaceuse spray foam insulation to R-49 attruss heelstruss clips each truss, each side-typical -by truss supplierrun exterior sheathing up to air chutefor insulation blockmetal drip edgecomposite board double fascia over2x6 sub fascia -match existingcomposite boar soffit with vents-match existingTypical Ceiling Construction:-blown insul. to R-49-4 mil poly V.B.-(1) layer 58" gyp. bd. ceilingTypical new exterior garage wall construction:-siding (match existing)-house wrap-12" O.S.B. sheathing-2x6 studs @ 16" O.C.-R-21 batt. insulation-4 mil poly vapor barrier-(1) layer 12" gyp. bd.4" concrete floor slab w/ 6x6-10/10W.W.M. on vapor barrier and 2"rigid insul. over 6" gravel fill-verify w/ owner if more or largerfloor reinforcement is needed-floor slopes 18" per ft. to front wall -verify drainage w/ owner5 courses 8" C.M.U. w/ 6" curb block at top -typical garage foundation walls -void curb at all door openings -dowel wall to footing -2" rigid insul. at inside face16"x8" footing w/ (2)#4 rerods continuous -typical @ garage wallssmall dashed line shows 6"x8"concrete curb at top of foundationwall -void at overhead doors1212126continuous screened ridge vent-match existing venting systemverify truss heel to matchexisting garage eave heighttreated 2x6 sill platew/ 12"x12" anchor bolts@ 48" O.C. at garagewallsnew foundation walland footing to line upwith existing garagefoundation wallowner option for atrough drain at frontGarage Addition for Bryce Austin 18268 Java Trail Lakeville, Mn. 55044A3 Date:5-12-20 gk DESIGN new and remodeled home design and drafting services Gene Klatt ph:(612)986-2262 e-mail: klattgr1@gmail.comsheet1A3GARAGE SECTION 12"=1'-0"In-Floor Heat tobe installed.