Loading...
HomeMy WebLinkAboutLA195562 Approved plans Solar 9 3 2021EXISTINGSNAPNRACKSITE MAP & PV LAYOUTELECTRICAL 1-LINE DIAGRAM ATTACHMENT LAYOUTSYSTEM LABELING DETAILINVERTER DATA SHEETSHEET INDEXPROPERTY PLANMODULE DATA SHEETRACKING DATA SHEETATTACHMENT DATA SHEETPV 1.0PV 2.0PV 4.0PV 5.1PV 6.0D 8.0D 9.0D 10.0SYSTEM RATINGEQUIPMENT SUMMARYELECTRICAL INFORMATIONMAIN SERVICE PANEL BUS SIZE:MAIN SERVICE BREAKER SIZE:MOUNTING SYSTEM:BUILDING INFORMATIONCONSTRUCTION TYPE: V-BOCCUPANCY: R3ROOF:Truss 2 x 4 @ 24" O.C.Comp ShingleVICINITY MAP (SCALE: NTS)SATELLITE VIEW (SCALE: NTS)GENERAL NOTES1.All electrical materials shall be new and listed by recognizedelectrical testing laboratory Custom made equipment shall have complete test data submittedby the manufacturer attesting to its safety2.Outdoor equipment shall be NEMA 3R rated or equivalent3.All metallic equipment shall be grounded4.Contractor shall obtain electrical permits prior to installation andshall coordinate all inspections, testing commissioning andacceptance with the client, utility co. and city inspectors as needed.5.The electrical contractor shall verify the exact locations of servicepoints and service sizes with the serving utility company andcomply with all utility companies requirements.6.Drawings are diagrammatic only, routing of raceways shall beoption of the contractor unless otherwise noted and shall becoordinated with other trades.7.If the roof material or the roof structure not adequate for PVinstallation, call the engineer of record print to installation. Thecontractor is responsible to verify that the roof is capable ofwithstanding the extra weight.8.If the distances for cable runs are different than shown, thecontractor shall notify the electrical engineer to validate the wiresize. Final drawings will be red-lined and updated as appropriate.9.Whenever a discrepancy in quality of equipment arises on thedrawing or specifications, the contractor shall be responsible forproviding and installing all materials and services required by thestrictest conditions noted on the drawings or in the specificationsto ensure complete compliance and longevity of the operablesystem required by the engineer of record.PHOTOVOLTAIC NOTES:1.Rooftop mounted photovoltaic panels and modules shall be tested,listed and identified by recognized testing laboratory2.Solar system shall not cover any plumbing or mechanical vents3.Modules and support structures shall be grounded unless racking has integrated ground.4.Removal of an interactive inverter or other equipment shall notdisconnect the bonding connection between the groundingelectrode conductor and the photovoltaic source and/or outputcircuit grounded conductors.5.All PV modules and associated equipment and wiring shall beprotected from physical damage.6.Live parts of PV source circuits and PV output circuits over 150v toground shall not be accessible to other than qualified persons while energized.7.Inverter is equipped with integrated DC disconnect, thus providingground fault protection8.All conductors shall be copper and 75 deg rated9.A single conductor shall be permitted to be used to perform themultiple functions of dc grounding, AC grounding and bondingbetween AC and DC systems.10.Non-current carrying metal parts of equipment shall be effectivelybonded together. Bond both ends of raceways.150A150A08/25/2021Property Address:Owner:Elliot & Megan StevensProperty Type:Single Family ResidenceDrawn by:New@engineerinc.ioDate:DC 10.64 KW STCAC 7.6 KW STC17726 Hollybrook Trail Lakeville, MN 55044CONTRACTORAddress:101 Isanti ParkwayNE, Isanti, MN 55040Phone number: (763) 229-6662E-mail: contact@wolfriverelectric.comTHE INSTALLATION OF SOLAR ARRAYS ANDPHOTOVOLTAIC POWER SYSTEMS SHALL COMPLY WITHTHE FOLLOWING CODES:·2020 National Electrical Code·2018 International Building Code·2018 International Residential Code·2020 Minnesota Residential Code·2020 Minnesota Building Code·2020 Minnesota Energy Code·2020 Minnesota Accessibility Code·2020 Minnesota State Fire Code·2018 International Fire Code·2018 International Energy Conservation Code·2018 Mechanical CodeAS ADOPTED BY THE STATE OF MINNESOTAALL OTHER ORDINANCE ADOPTED BY THELOCAL GOVERNING AGENCIESGOVERNING CODESPV 3.128 JINKO 380 WATT MODULES WITH P370 POWEROPTIMIZERS, SOLAREDGE HD WAVE 7.6KW INVERTERSOPTIMIZER DATA SHEETPV 7.0D 11.0SURGE PROTECTIOND 12.0D 13.0INVERTER CERTIFICATIOND 14.0PV INSPECTION CHECKLISTINVERTER CERTIFICATION ATTACHMENT DETAILPV 5.2PLACARDPV 3.2Date Certified andSigned: 9/03/2021 SOLAR MODULES___JINKO 380WattModel #JKM380M-6RL3-BEMT type ConduitSolar Module(N) Junction BoxJB.........................................................28MSP(E) Main Service Panel150AINDEX(N) Production MeterPM..............AC...................(N) 60A Utility AC(N) OptimizerNOTE: Conduit in attic shallbe minimum 18 inches from roof sheating* Roof access is not located in areas that require placement of ground ladders over exterior wall openings CRC R331.4.1.SITE MAP & PVLAYOUTPV 1.0PV SYSTEMAS INDICATEDScale:Project:Project Name:Property Adress:Elliot & Megan Stevens17726 Hollybrook TrailLakeville, MN 55044CONTRACTORIN(N) Inverter..............................Wolf RIver ElectircAddress:101 Isanti ParkwayNE, Isanti, MN 55040Phone number: (763) 229-6662E-mail: contact@wolfriverelectric.comNOTE: No clearance issue Distance between all equipments is maximum 10"(E) Main MeterMM........................FMT type Conduit..............SECONDARY INTERCONNECTIONEQUIPMENT ELEVATIONMainServicePanelUtility ACDisconnectProductionMeter10"4'MainMeterOutside Outside Inside Inside <10'Dakota Electric Application#:TBDNote: 24/ 7 Unescorted keyless access is to beprovided for ALL UTILITY EQUIPMENT..........................SolarEdgeStorEdgeNOTE:A 36-inchwide pathwayshall be provided to the emergencyescape and rescue opening.From roofINVERTERINVERTER TYPE: Central:Solar Edge Single Phase HD Wave7.6 kW Technology InverterModel #SE 7600H-US(240V)Setback............................Drawn by: New@engineerinc.io08/25/2021DATE:3' fire setback 3' fire setback 3' fire setback 3' fire pathway 3' fire setback3' fire setback3' fire setbackSolar PV Array 222 - Jinko 380W Modules22 - P400 Power OptimizersPitch: 30 DegOrientation: 181 DegHollybrook TrailaaaaaaaaaaaaaabbbbbbbbbbbbbbINACPMMMMSP''Roof Access''Solar PV Array 16 - Jinko 380W Modules6 - P400 Power OptimizersPitch: 26 DegOrientation: 181 DegJBSCALE:3/32" = 1'-0" 180° 90° 270°0°SWNE (4) #10 AWG THWN/THWN-2(1) #8 AWG GND3/4" FMT, 15 FEET1J BOXNEMA3R6STRING - A2 PV 2.0PV SYSTEMAS INDICATEDScale:Project:Project Name:Property Adress:Elliot & Megan Stevens17726 Hollybrook TrailLakeville, MN 55044ELECTRICAL 1-LINE DIAGRAMCONTRACTORPV Production meter socket must have leverbypass/bypass60A FUSED AC DISCONNECT,WITH 40A FUSESUTILITY AC DISCONNECT VISIBLE-OPENLOCKABLE, READILY ACCESSIBLENEMA3R120 / 240V32AWolf RIver ElectircAddress:101 Isanti ParkwayNE, Isanti, MN 55040Phone number: (763) 229-6662E-mail: contact@wolfriverelectric.comEXISTING______ MAINSERVICEPANEL120/240V,1P, 3WGEC(E) GROUNDINGELECTRODE SYSTEM150ANOTE: Service Panel does not contain center fed Main Breaker:SECONDARY INTERCONNECTIONATT:PLEASE REFER TO WH NETMEETERING GUIDE:APPENDIX GThe lockable visible disconnect must be located within 5 feet from the GeneralService Meter and must be located onthe exterior of the buildingMeter Socket must be 150A ratedand must have lever BypassLoad32ADakota Electric Application#:TBDNote: 24/ 7 Unescorted keyless access is to beprovided for ALL UTILITY EQUIPMENTProduction meter is required based on the der sizeand program under which the application is submittedDesign meet National Electric Code(NEC codes)For smaller DERs, using the PoC as the Reference Point of Applicability allows the DERequipment type testing certification to be utilized as the main method by whichcompliancewith the Standard is verified. The PoC might be the terminals of an inverter, for example,and utilizing a UL 1741 certified and listed inverter would be sufficient to demonstrateStandard compliance. In locations where there is no local Public Authority, the customer is exempt frominspection, and/or the service has been shut off or disconnected for more than 365 days (1 year),the licensed electrician or wireman shall submit a signed and dated Dakota Electric ElectricalInspection Certificate to the Company’s Builders Call Line attesting that the electrical installationhas been completed and installed according to the current National Electrical Code®, the DakotaElectric Standard for Electric Installation and Use, and any other applicable codes that apply beforeelectric service is energized.AtticWall MAIN METER120/240V,1P, 3W(4) #10 AWG THWN/THWN-2(1) #8 AWG GND3/4" EMT, 5 FEETNOTE:UTILITY HAS 24 HOURUNRESTRICTED ACCESS TO ALL PVSYSTEM COMPONENTS LOCATED ATSERVICE ENTRANCE.If there is cold water bonding and UFER , no additionalsupplementary rod is requiredIf there is no UFER new ground rod shall be installedIf existing ground rod is more than 25-OHM than a new ground rodshall be installedEXISTINGNON CENTER _____MAIN C/B150AJINKO 380W WATT MODULES28P400 POWER OPTIMIZER28LINE SIDE TAP(3) #8AWG THWN/THWN-2(1) #8 AWG GND3/4" EMT, 2 FEETSurge ProtectionMNSPD-300-ACREFERENCE POIN OF APPLICABILITY(3)#6AWG CU-XHHW(1) #6 AWG GND3/4" EMT, 2 FEETINVERTERSOLAR EDGE HD WAVE 7.6 kWMODEL #SE 7600H-US(240V)Line32ASQUARE-D-200A PV productionmeter socket with stampedbrass aluminium or stainlesssteel tag labeled in accordancewith NEC and AHJ requirmentslocated within 5' of main.Inverter output wired to load sideterminal of meter 1 phase 3-wire120/240V18STRING - A2 (2) #10 AWG PV WIRE,(1) #10 AWG EGCFREE IN THE AIR(3) #6AWG CU-XHHW(1) #6 AWG GND3/4" EMT, 2 FEET6000SolarEdge Power OptimizerRated DC Input Power -Maximum Input Voltage - 80 VdcMPPT Range - 8 to 80 VdcMaximum Input Current - 13.5 AdcMaximum Output Current - 15 AdcString Limitations - 8 to 25Optimizers, watts STC per string maximum.Solaredge optimizers have integratedrapid shut downP400400 wattsDC 10.64 KW STCAC 7.6 KW STCDrawn by: New@engineerinc.io08/25/2021DATE:114STRING - B2PV ARRAY RATINGWIRE SIZE CALCULATIONPV ARRAYFROM JUNCTION BOX TO INVERTERNumber Modules28TypeJKM380M-6RL3-BJINKO 380 WATTMaximum Current (A)14 * 380 / 400 = 13.3Number Inverters1Solar Edge 7.6kW Inverter with OptimizersSE7600H-US (240V)Considers Continuous (A)13.3 * 1.25 = 16.63LocationWatts STC, (Watts/Module) 28 * 380 = 10640Short Circuit Current (A)16.63 * 1.25 = 20.79Array CurrentsI-SC11.12AI-MP10.3ARaceway Height From Roof (Temp 39+22=61C)3 1/2"Module VoltageV-OC44.22VV-MP36.9VTemp. Derate Factor (A)20.79 / 0.71 = 29.28SYSTEM POWER#of wire(#of Strings*2)4Number Of Strings2Max Number of Modules Per String14More Than 3 CCC Adjist. Factor0.8Max DC Wattage In Strings14 * 380 = 5320 < 6000 (Watts)Max AC Voltage 120/240VAdjusted Conductor Ampacity(A)29.28 / 0.8 = 36.6FROM INVERTER TO MAIN PANELWire Size from NEC Table 310.15(b)1610 AWGTotal Current (A)32Ambiend Tem Factor Per NEC Table 310.15(b)(2)(a)0.71Total AC Wattage (Watts)7600Consider Continuous (A)32 * 1.25 = 40Temperature Adjustment40 / 0.91 = 43.96AConductor Size From NEC Table 310.166 AWG PV SYSTEMAS INDICATEDScale:Project:Project Name:Property Adress:Elliot & Megan Stevens17726 Hollybrook TrailLakeville, MN 55044SYSTEM LABELING DETAILPV 3.1CONTRACTORWolf RIver ElectircAddress:101 Isanti ParkwayNE, Isanti, MN 55040Phone number: (763) 229-6662E-mail: contact@wolfriverelectric.comDrawn by: New@engineerinc.io08/25/2021DATE:PV ARRAYJ BOXPV SUB-PANELACDISCONNECTPVPRODUCTIONMETERMAIN SERVICEPANELMETER12333331617218135Note: LABELS SHALL COMPLY WITH NEC 690“Labels shall be weatherproof, durable and permanently mounted”40Production MeterLABEL 1Photovoltaic Power SourceLABEL 2CAUTION: SOLAR CIRCUITLABEL 3WARNINGELECTRIC SHOCK HAZARDTHE DC CONDUCTORS OF THISPHOTOVOLTAIC SYSTEM AREUNDERGROUND AND MAY BE ENERGIZEDLABEL 4WARNINGELECTRIC SHOCK HAZARDIF GROUND FAULT IS INDICATEDNORMALLY GROUNDED CONDUCTORSMAY BE UNDERGROUND AND ENERGIZEDLABEL 5WARNINGELECTRIC SHOCK HAZARDDO NOT TOUCH TERMINALSTERMINALS ON BOTH LINE AND LOADSIDES MAY BE ENERGIZED IN THE OPENPOSITIONLABEL 6WARNINGELECTRIC SHOCK HAZARDDO NOT TOUCH TERMINALSTERMINALS ON BOTH LINE AND LOADSIDES MAY BE ENERGIZED IN THE OPENPOSITIONDC VOLTAGE IS ALWAYS PRESENTWHEN SOLAR MODULESARE EXPOSED TO SUNLIGHTLABEL 7WARNINGLABEL 8TURN OF PHOTOVOLTAICAC DISCONNECT PRIOR TOWORKING INSIDE PANELDO NOT DISCONNECTUNDER LOADLABEL 9MAIN PV SYSTEMDISCONNECTLABEL 10MAIN PV SYSTEMAC DISCONNECTLABEL 11LABEL 12CAUTIONLABEL 13SOLAR ELECTRIC SYSTEMCONNECTEDWARNING-LABEL 14 DUAL POWER SOURCESECOND SOURCE IS PV SYSTEMCAUTIONLABEL 15PHOTOVOLTAIC SYSTEM CIRCUITIS BACKFEDLABEL 16PHOTOVOLTAIC AC DISCONNECTMAXIMUM AC OPERATING CURRENTMAXIMUM AC OPERATING CURRENTPHOTOVOLTAICLABEL 17UTILITY AC DISCONNECTPHOTOVOLTAICLABEL 18DC DISCONNECTNOMINAL OPERATING AC VOLTAGENOMINAL OPERATING AC FREQUANCYMAXIMUM AC POWERMAXIMUM AC CURRENTMAX OCERCURRENT DEVICE RATINGFOR AC MODULE PROTECTIONLABEL 19LABEL 20PV SYSTEM DC DISCONNECTOPERATING CURRENTOPERATING VOLTAGEMAXIMUM SYSTEM VOLTAGESHORT CIRCUIT CURRENTCAUTIONLABEL 21PHOTOVOLTAIC SOURCECONNECTED***ALL LABELS = RED THERMOPLASTIC/REFLECTIVE , Permanently mounted240VSOLAR DISCONNECT21SOLAR PV SYSTEM EQUIPPEDWITH RAPID SHUTDOWNTURN RAPID SHUTDOWNSWITCH TO THE"OFF" POSITION TOSHUT DOWN PV SYSTEMAND REDUCESHOCK HAZARDIN THE ARRAYSOLAR ELECTRICPV PANELS PLACARDPV 3.0PV SYSTEMAS INDICATEDScale:Project:Project Name:Property Adress:Elliot & Megan Stevens17726 Hollybrook TrailLakeville, MN 55044CONTRACTORWolf RIver ElectircAddress:101 Isanti ParkwayNE, Isanti, MN 55040Phone number: (763) 229-6662E-mail: contact@wolfriverelectric.comINSTALL 40A PVINSTALL 20A PVDrawn by: New@engineerinc.io08/25/2021DATE:CAUTIONPOWER TO THIS BUILDING IS ALSO SUPPLIEDFROM THE FOLLOWING SOURCES WITHDISCONNECTS LOCATED AS SHOWN:CAUTIONPOWER TO THIS BUILDING IS ALSO SUPPLIEDFROM THE FOLLOWING SOURCES WITHDISCONNECTS LOCATED AS SHOWN:SERVICE 1 OF 2SERVICE 2 OF 217726 Hollybrook Trail Lakeville, MN 5504417726 Hollybrook Trail Lakeville, MN 55044NWESNWESSERVICE POINT &UTILITY METERINGSOLAR INVERTERPV SYSTEM DISCONNECTFOR UTILITY OPERATIONYou AreHerePERFORMANCE METERSOLAR PV ARRAYSERVICE POINT &UTILITY METERINGSOLAR INVERTERPV SYSTEM DISCONNECTFOR UTILITY OPERATIONYou AreHerePERFORMANCE METERSOLAR PV ARRAY PROPERTY PLANLEGENDMSPMain Service Panel................ Production MeterPM.................. AC DisconnectAC.........................PV 4.0PV SYSTEMAS INDICATEDScale:Project:Project Name:Property Adress:Elliot & Megan Stevens17726 Hollybrook TrailLakeville, MN 55044CONTRACTORInverterIN.......................................Wolf RIver ElectircAddress:101 Isanti ParkwayNE, Isanti, MN 55040Phone number: (763) 229-6662E-mail: contact@wolfriverelectric.comMMMain Meter............................Dakota Electric Application#:TBDNote: 24/ 7 Unescorted keyless access is to beprovided for ALL UTILITY EQUIPMENTDrawn by: New@engineerinc.io08/25/2021DATE:102'-1"104'-2"59'-3"65'-3"Hollybrook TrailINACPMMMMSPPROPERTY LINEP. de Arq. Enrique Guerrero Hernández.P. de Arq. Adrian A. Romero Arguelles.P. de Arq. Francisco Espitia Ramos.P. de Arq. Hugo Suárez Ramírez. P. de Arq. Enrique Guerrero Hernández.P. de Arq. Adrian A. Romero Arguelles.P. de Arq. Francisco Espitia Ramos.P. de Arq. Hugo Suárez Ramírez. P. de Arq. Enrique Guerrero Hernández.P. de Arq. Adrian A. Romero Arguelles.P. de Arq. Francisco Espitia Ramos.P. de Arq. Hugo Suárez Ramírez. P. de Arq. Enrique Guerrero Hernández.P. de Arq. Adrian A. Romero Arguelles.P. de Arq. Francisco Espitia Ramos.P. de Arq. Hugo Suárez Ramírez.P. de Arq. Enrique Guerrero Hernández.P. de Arq. Adrian A. Romero Arguelles.P. de Arq. Francisco Espitia Ramos.P. de Arq. Hugo Suárez Ramírez. P. de Arq. Enrique Guerrero Hernández.P. de Arq. Adrian A. Romero Arguelles.P. de Arq. Francisco Espitia Ramos.P. de Arq. Hugo Suárez Ramírez. P. de Arq. Enrique Guerrero Hernández.P. de Arq. Adrian A. Romero Arguelles.P. de Arq. Francisco Espitia Ramos.P. de Arq. Hugo Suárez Ramírez. P. de Arq. Enrique Guerrero Hernández.P. de Arq. Adrian A. Romero Arguelles.P. de Arq. Francisco Espitia Ramos.P. de Arq. Hugo Suárez Ramírez. P. de Arq. Enrique Guerrero Hernández.P. de Arq. Adrian A. Romero Arguelles.P. de Arq. Francisco Espitia Ramos.P. de Arq. Hugo Suárez Ramírez. P. de Arq. Enrique Guerrero Hernández.P. de Arq. Adrian A. Romero Arguelles.P. de Arq. Francisco Espitia Ramos.P. de Arq. Hugo Suárez Ramírez.151'-7"132'-1"24'13'-8"SCALE:1/16" = 1'-0" 180° 90° 270°0°SWNEDate Certified andSigned: 9/03/2021 ATTACHMENTLAYOUTPV 5.1PV SYSTEMAS INDICATEDScale:Project:Project Name:Property Adress:Elliot & Megan Stevens17726 Hollybrook TrailLakeville, MN 55044CONTRACTORWolf RIver ElectircAddress:101 Isanti ParkwayNE, Isanti, MN 55040Phone number: (763) 229-6662E-mail: contact@wolfriverelectric.comDESIGN CRITERIAModules:Max Distributed Load: 3 PSFPOINT LOAD CALCULATION PER ARRAYModule Weight (lbs)# Of Modules45.86Total Module Weight (lbs)Rack Weight (lbs)Optimizers Weight (lbs)Total System Weight (lbs)# Of StandoffsMax Span Between Standoffs (in)Loading Per Standoff (lbs)Total Area (sq.ft.)Loading (PSF)1284.08256.8147.61588.491074814.846162.57RAIL ATTACHMENTMODULES ON ROOFTruss 2 x 4 @ 24" O.C.2828Dakota Electric Application#:TBDNote: 24/ 7 Unescorted keyless access is to beprovided for ALL UTILITY EQUIPMENT1 Layer of .Plywood & Building FeltSolar Module6"AttachmentMODULES ON ROOFTruss 2 x 4 @ 24" O.C.StandingSeam Metal1.86"3.05"0.25"Ø2.24"2.58"1"0.17"3.20"1.37"0.38"0.30"1.08"2.78"1.78"1.50"1.99"1.21"R 1.12"Ø0.33"R 0.82"12345SNAPNRACK, SPEEDSEAL FOOT, BASE, SEALING, SILVER/BLACKBOLT, FLANGE, SERRATED, 5/16IN-18 X 2IN, SSSNAPNRACK, RL UNIVERSAL, MOUNT SPRING, SSSNAPNRACK, ULTRA RAIL MOUNT THRU PRC, CLEAR/BLACKSNAPNRACK, ULTRA RAIL MOUNT TAPPED PRC, CLEAR/BLACK12345DESCRIPTIONITEMQTI11111MATERIALS:DESIGN LOAD (LBS):ULTIMATE LOAD (LBS):TORQUE SPECIFICATION:CERTIFICATION:WEIGHT (LBS):DIE CAST A380 ALUMINUM, 6000 SERIES ALUMINUM, STAINESS STEEL802 UP, 1333 DOWN, 357 SIDE2118 UP, 4006 DOWN, 1331 SIDE12 LB-FTUL 2703, FILE E359313; WIND-DRIVEN RAIN TEST FROM SUBJECT UL 25820.45OPTIONS:CLEAR/BLACKPARTS LISTSNAPNRACK, ULTRA RAIL SPEEDSEAL TM FOOT2x4PurlinDrawn by: New@engineerinc.io08/25/2021DATE:Prior to the commencement of work, the contractor shall verify the existing roof and framingconditions. Notify New@engineerinc.io of any Discrepancies prior to starting construction.Prior to the commencement of work, the contractor shall inspect framing for any damagesuch as water damage, cracked framing, etc. and notify New@engineerinc.io if any issuesare found.These Plans are stamped for structural code compliance of the roof framing supporting theproposed PV installation reference only. These plans are not stamped for water leakage.PV modules, racking, and attachment components must follow manufacturer guidelinesand requirements.Attachments to be installed in a staggered orientation to properly distribute loads.Date Certified andSigned: 9/03/2021 PV 5.2PV SYSTEMAS INDICATEDScale:Project:Project Name:Property Adress:Elliot & Megan Stevens17726 Hollybrook TrailLakeville, MN 55044ATTACHMENT DETAILCONTRACTORWolf RIver ElectircAddress:101 Isanti ParkwayNE, Isanti, MN 55040Phone number: (763) 229-6662E-mail: contact@wolfriverelectric.comDrawn by: New@engineerinc.io08/25/2021DATE: INVERTERDATA SHEETINVERTERDATA SHEETD 6.0PV SYSTEMAS INDICATEDScale:Project:Project Name:Property Adress:Elliot & Megan Stevens17726 Hollybrook TrailLakeville, MN 55044CONTRACTORWolf RIver ElectircAddress:101 Isanti ParkwayNE, Isanti, MN 55040Phone number: (763) 229-6662E-mail: contact@wolfriverelectric.comDrawn by: New@engineerinc.io08/25/2021DATE: POWER OPTIMIZERDATA SHEETD 7.0PV SYSTEMAS INDICATEDScale:Project:Project Name:Property Adress:Elliot & Megan Stevens17726 Hollybrook TrailLakeville, MN 55044CONTRACTORWolf RIver ElectircAddress:101 Isanti ParkwayNE, Isanti, MN 55040Phone number: (763) 229-6662E-mail: contact@wolfriverelectric.comDrawn by: New@engineerinc.io08/25/2021DATE: MODULEDATA SHEETD 8.0PV SYSTEMAS INDICATEDScale:Project:Project Name:Property Adress:Elliot & Megan Stevens17726 Hollybrook TrailLakeville, MN 55044CONTRACTORWolf RIver ElectircAddress:101 Isanti ParkwayNE, Isanti, MN 55040Phone number: (763) 229-6662E-mail: contact@wolfriverelectric.comDrawn by: New@engineerinc.io08/25/2021DATE: RACKINGDATA SHEETD 9.0PV SYSTEMAS INDICATEDScale:Project:Project Name:Property Adress:Elliot & Megan Stevens17726 Hollybrook TrailLakeville, MN 55044CONTRACTORWolf RIver ElectircAddress:101 Isanti ParkwayNE, Isanti, MN 55040Phone number: (763) 229-6662E-mail: contact@wolfriverelectric.comDrawn by: New@engineerinc.io08/25/2021DATE: ATTACHMENTDATA SHEETD 10.0PV SYSTEMAS INDICATEDScale:Project:Project Name:Property Adress:Elliot & Megan Stevens17726 Hollybrook TrailLakeville, MN 55044CONTRACTORWolf RIver ElectircAddress:101 Isanti ParkwayNE, Isanti, MN 55040Phone number: (763) 229-6662E-mail: contact@wolfriverelectric.comDrawn by: New@engineerinc.io08/25/2021DATE: D 11.0PV SYSTEMAS INDICATEDScale:Project:Project Name:Property Adress:Elliot & Megan Stevens17726 Hollybrook TrailLakeville, MN 55044CONTRACTORSURGE PROTECTIONWolf RIver ElectircAddress:101 Isanti ParkwayNE, Isanti, MN 55040Phone number: (763) 229-6662E-mail: contact@wolfriverelectric.comDrawn by: New@engineerinc.io08/25/2021DATE: D 12.0PV SYSTEMAS INDICATEDScale:Project:Project Name:Property Adress:Elliot & Megan Stevens17726 Hollybrook TrailLakeville, MN 55044CONTRACTORINVERTERCERTIFICATIONWolf RIver ElectircAddress:101 Isanti ParkwayNE, Isanti, MN 55040Phone number: (763) 229-6662E-mail: contact@wolfriverelectric.comDrawn by: New@engineerinc.io08/25/2021DATE: D 13.0PV SYSTEMAS INDICATEDScale:Project:Project Name:Property Adress:Elliot & Megan Stevens17726 Hollybrook TrailLakeville, MN 55044CONTRACTORWolf RIver ElectircAddress:101 Isanti ParkwayNE, Isanti, MN 55040Phone number: (763) 229-6662E-mail: contact@wolfriverelectric.comINVERTERCERTIFICATIONDrawn by: New@engineerinc.io08/25/2021DATE: D 14.0PV SYSTEMAS INDICATEDScale:Project:Project Name:Property Adress:Elliot & Megan Stevens17726 Hollybrook TrailLakeville, MN 55044PV INSPECTIONCHECKLISTCONTRACTORWolf RIver ElectircAddress:101 Isanti ParkwayNE, Isanti, MN 55040Phone number: (763) 229-6662E-mail: contact@wolfriverelectric.comWolf RIver ElectricLakeville, MN 5504417726 Hollybrook TrailDrawn by: New@engineerinc.io08/25/2021DATE: