Loading...
HomeMy WebLinkAboutApproved 19525_jasper_terrace_Roof racking standard detailsSystem Weight Total system weight 155.0 lbs Weight/attachment 25.8 lbs Racking weight 29.4 lbs Distributed weight 2.8 psf Load Assumptions Wind exposure B Wind speed 115 mph Ground snow load 50 psf Attachment spacing 4.0' Span Details XR100 - Portrait Zone Max span Max cantilever 1 6' 8"2' 8" 2 6' 8"2' 8" 3 6' 8"2' 8" Reaction Forces XR100 - Portrait Zone Down (lbs) Uplift (lbs) Lateral (lbs) 1 255 114 121 2 255 141 121 3 255 141 121 Project Details Name 19525 Jasper Terrace Date 06/16/2020 Location 19525 Jasper Terrace, Lakeville, MN 55044 Total modules 3 Module Axitec Solar : AC-320MH/120S (35mm)Total watts 960 Dimensions 66.3" x 39.45" x 1.38" (1684.0mm x 1002.0mm x 35.0mm)Attachments 6 ASCE 7-10 Roof Information Roof material Comp Shingle Building height 30 ft Roof attachment Flashfoot2 Roof slope 30 ° Attachment hardware Square Risk category II Roof Section 1 Definition Roof Section Weights Roof Section (all segments) 3 modules Total weight: 155.0 lbs Provided rail: 28' [2 x 14'] Portrait orientation Weight/attachment: 25.8 lbs Attachments: 6 Graphical entry Total Area: 55.8 sq ft Splices: 0 Distributed weight: 2.8 psf Clamps: 8 Diagram 9' 11"5' 6"Segments Columns Length Cantilever Cantilever Violations Rail Attachments Splices Clamps 3 10' 1"1' 1"None 28' [2 x 14']6 0 8 Last updated by Brian Harrison on 06/16/20 12:07 PM Page 1 of 5 19525 Jasper Terrace (#627745) pitched roof 28357 INDUSTRIAL BLVD., HAYWARD, CA 94545 Side View (portrait) 30° BUILDING STRUCTURE ROOF MEMBRANE FLASHFOOT2 RAIL PV MODULE Front View (portrait) ATTACHMENT SPAN 4.0’ BUILDING STRUCTURE ROOF MEMBRANE FLASHFOOT2 RAIL PV MODULE Last updated by Brian Harrison on 06/16/20 12:07 PM Page 2 of 5 19525 Jasper Terrace (#627745) pitched roof 28357 INDUSTRIAL BLVD., HAYWARD, CA 94545 Splice Details XR100 SIDE-FACING SLOT INTERNAL SPLICE TOP-FACING SLOT Splice Connection INTERNAL SPLICE RAIL SELF-DRIVING SCREW Clamp Detail Mid Clamp, Plan UNIVERSAL FASTENING OBJECT PV MODULE FRAME Mid Clamp, Front RAIL PV MODULEFRAME UNIVERSALFASTENINGOBJECT End Clamp, Plan STOPPERSLEEVE UNIVERSALFASTENINGOBJECT PV MODULEFRAME RAIL 1” End Clamp, Front PV MODULEFRAME RAIL UNIVERSALFASTENINGOBJECT STOPPERSLEEVE1” FlashFoot2 Detail Plan View 9” 12” 2 “316 Side View 1 “1116 Perspective View Front View 1 “58 3 “516 “516 Last updated by Brian Harrison on 06/16/20 12:07 PM Page 3 of 5 19525 Jasper Terrace (#627745) pitched roof 28357 INDUSTRIAL BLVD., HAYWARD, CA 94545 Grounding Diagram * Grounding Lugs and Wire are not required in systems using Enphase microinverters. UFO Clamp Fault Current Ground Path Min 10 AWG Copper Wire * Grounding Lug * Bonded Splice (Rail Connection) Last updated by Brian Harrison on 06/16/20 12:07 PM Page 4 of 5 19525 Jasper Terrace (#627745) pitched roof 28357 INDUSTRIAL BLVD., HAYWARD, CA 94545 Bill of Materials Part Spares Total Qty Rails & Splices XR-100-168A XR100, Rail 168" (14 Feet) Clear 0 2 Clamps & Grounding UFO-CL-01-A1 Universal Module Clamp, Clear 0 8 UFO-STP-35MM-M1 Stopper Sleeve, 35MM, Mill 0 4 XR-LUG-03-A1 Grounding Lug, Low Profile 0 1 Attachments FF2-01-M2 FlashFoot2, Mill 0 6 BHW-SQ-02-A1 Square-Bolt Bonding Hardware 0 6 Accessories BHW-MI-01-A1 Microinverter Bonding Hardware, T-Bolt 0 3 Last updated by Brian Harrison on 06/16/20 12:07 PM Page 5 of 5 19525 Jasper Terrace (#627745) pitched roof 28357 INDUSTRIAL BLVD., HAYWARD, CA 94545