Loading...
HomeMy WebLinkAboutApproved plan_19525_jasper_terrace_20210903System Weight Total system weight 1,229.1 lbs Weight/attachment 23.6 lbs Racking weight 209.4 lbs Distributed weight 2.7 psf Load Assumptions Wind exposure B Wind speed 115 mph Ground snow load 50 psf Attachment spacing portrait 4.0' Attachment spacing landscape 4.0' Span Details XR100 - Portrait Zone Max span Max cantilever 1 6' 8"2' 8" 2 6' 8"2' 8" 3 6' 8"2' 8" Reaction Forces XR100 - Portrait Zone Down (lbs) Uplift (lbs) Lateral (lbs) 1 253 113 120 2 253 140 120 3 253 140 120 Span Details XR100 - Landscape Zone Max span Max cantilever 1 7' 11"3' 2" 2 7' 11"3' 2" 3 7' 11"3' 2" Reaction Forces XR100 - Landscape Zone Down (lbs) Uplift (lbs) Lateral (lbs) 1 150 67 71 2 150 83 71 3 150 83 71 Project Details Name 19525 Jasper Terrace Date 09/03/2021 Location 19525 Jasper Terrace, Lakeville, MN 55044 Total modules 25 Module Canadian Solar: CS3K-320MS (35mm)Total watts 8,000 Dimensions 65.94" x 39.06" x 1.38" (1675.0mm x 992.0mm x 35.0mm)Attachments 52 ASCE 7-10 Rails per row 2 Roof Information Roof material Comp Shingle Building height 30 ft Roof attachment Flashfoot2 Roof slope 30 ° Attachment hardware Square Risk category II Last updated by Brian Harrison on 09/03/21 06:48 AM Page 1 of 8 19525 Jasper Terrace (#817654) pitched roof 28357 INDUSTRIAL BLVD., HAYWARD, CA 94545 Roof Section 1 Definition Roof Section Weights Roof Section (all segments) 19 modules Total weight: 923.8 lbs Provided rail: 130' [2 x 14', 6 x 17'] East-West rail orientation Weight/attachment: 24.3 lbs Attachments: 38 Portrait module orientation Total Area: 347.1 sq ft Splices: 0 Graphical entry Distributed weight: 2.7 psf Clamps: 46 Diagram 16' 3"22'Segments Columns Length Cantilever Cantilever Violations Rail Attachments Splices Clamps 4 13' 3"8"None 28' [2 x 14']8 0 10 5 16' 7"3"None 34' [2 x 17']10 0 12 Row segment totals (x 3) →102' [6 x 17']30 0 36 Roof Section 2 Definition Roof Section Weights Roof Section (all segments) 4 modules Total weight: 195.1 lbs Provided rail: 28' [2 x 14'] East-West rail orientation Weight/attachment: 24.4 lbs Attachments: 8 Portrait module orientation Total Area: 73.0 sq ft Splices: 0 Graphical entry Distributed weight: 2.7 psf Clamps: 10 Diagram 13'11'Segments Columns Length Cantilever Cantilever Violations Rail Attachments Splices Clamps 4 13' 3"8"None 28' [2 x 14']8 0 10 Last updated by Brian Harrison on 09/03/21 06:48 AM Page 2 of 8 19525 Jasper Terrace (#817654) pitched roof 28357 INDUSTRIAL BLVD., HAYWARD, CA 94545 Roof Section 3 Definition Roof Section Weights Roof Section (all segments) 2 modules Total weight: 110.2 lbs Provided rail: 28' [2 x 14'] East-West rail orientation Weight/attachment: 18.4 lbs Attachments: 6 Landscape module orientation Total Area: 36.4 sq ft Splices: 0 Graphical entry Distributed weight: 3.0 psf Clamps: 6 Diagram 11'3' 3"Segments Columns Length Cantilever Cantilever Violations Rail Attachments Splices Clamps 2 11' 2"1' 7"None 28' [2 x 14']6 0 6 Side View (portrait) 30° BUILDING STRUCTURE ROOF MEMBRANE FLASHFOOT2 RAIL PV MODULE Last updated by Brian Harrison on 09/03/21 06:48 AM Page 3 of 8 19525 Jasper Terrace (#817654) pitched roof 28357 INDUSTRIAL BLVD., HAYWARD, CA 94545 Front View (portrait) ATTACHMENT SPAN 4.0’ BUILDING STRUCTURE ROOF MEMBRANE FLASHFOOT2 RAIL PV MODULE Last updated by Brian Harrison on 09/03/21 06:48 AM Page 4 of 8 19525 Jasper Terrace (#817654) pitched roof 28357 INDUSTRIAL BLVD., HAYWARD, CA 94545 Side View (landscape) 30° BUILDING STRUCTURE ROOF MEMBRANE FLASHFOOT2 RAIL PV MODULE Front View (landscape) ATTACHMENT SPAN 4.0’ BUILDING STRUCTURE ROOF MEMBRANE FLASHFOOT2 RAIL PV MODULE Last updated by Brian Harrison on 09/03/21 06:48 AM Page 5 of 8 19525 Jasper Terrace (#817654) pitched roof 28357 INDUSTRIAL BLVD., HAYWARD, CA 94545 Splice Details INTERNAL SPLICE SIDE-FACING SLOT TOP-FACING SLOT XR100 XR100 RAIL BONDING SPRING XR100 INTERNAL SPLICE Splice Connection Clamp Detail Mid Clamp, Plan UNIVERSAL FASTENING OBJECT PV MODULE FRAME Mid Clamp, Front RAIL PV MODULEFRAME UNIVERSALFASTENINGOBJECT End Clamp, Plan STOPPERSLEEVE UNIVERSALFASTENINGOBJECT PV MODULEFRAME RAIL 1” End Clamp, Front PV MODULEFRAME RAIL UNIVERSALFASTENINGOBJECT STOPPERSLEEVE1” FlashFoot2 Detail Plan View 9” 12” 2 “316 Side View 1 “1116 Perspective View Front View 1 “58 3 “516 “516 Last updated by Brian Harrison on 09/03/21 06:48 AM Page 6 of 8 19525 Jasper Terrace (#817654) pitched roof 28357 INDUSTRIAL BLVD., HAYWARD, CA 94545 Grounding Diagram * Grounding Lugs and Wire are not required in systems using Enphase microinverters. UFO Clamp Fault Current Ground Path Min 10 AWG Copper Wire * Grounding Lug * Bonded Splice (Rail Connection) Last updated by Brian Harrison on 09/03/21 06:48 AM Page 7 of 8 19525 Jasper Terrace (#817654) pitched roof 28357 INDUSTRIAL BLVD., HAYWARD, CA 94545 Bill of Materials Part Spares Total Qty Rails & Splices XR-100-204A XR100, Rail 204" (17 Feet) Clear 0 6 XR-100-168A XR100, Rail 168" (14 Feet) Clear 0 6 Clamps & Grounding UFO-CL-01-A1 Universal Module Clamp, Clear 0 62 UFO-STP-35MM-M1 Stopper Sleeve, 35MM, Mill 0 24 XR-LUG-03-A1 Grounding Lug, Low Profile 0 6 Attachments FF2-01-M2 FlashFoot2, Mill 0 52 BHW-SQ-02-A1 Square-Bolt Bonding Hardware 0 52 Last updated by Brian Harrison on 09/03/21 06:48 AM Page 8 of 8 19525 Jasper Terrace (#817654) pitched roof 28357 INDUSTRIAL BLVD., HAYWARD, CA 94545