HomeMy WebLinkAboutLA195193 Approved engineering 20696 JAGUAR TERRLEGEND DESIGNER: ÐÐ SCALE: CUSTOM DATE: 8/16/2021 2015 IRC / 2020 NEC / 2015 IBC SITE PLAN INVERTER LOCATION SE7600 1PHASE 240 VOLT 3 WIRE. UTILITY METER LOCATION 1PHASE 120/240VOLT 100A 3 WIRE CUSTOMER OWNED AC DISCONNECT 1PHASE 120/240 VOLT 40AMP FUSES 3 WIRE. UTILITY OWNED 120/240V 200AMP 1PHASE PRODUCTION METER 3 WIRE. EXISTING 200A 1PH 120/240 VOLT MAIN PANEL LOCATED IN HOUSE 3 WIRE. 17 PV MODULE MISSSION 340WATT PV MODULE EACH WITH P400 OPTIMIZERS. FIRE EGRESS PATHWAYS 12" EAVES18" HIPS & VALLEY 36" RIDGE & RAKE SITE SPECIFICATIONS •INVERTER SHALL BE CERTIFIED UNDER UL1741 •24/7 UNESCORTED KEYLESS ACCESS SHALL BE PROVIDED TO XCELL EQUPMENT •THERE ARE OVERHEAD UTILITIES TO THE PROPERTY BUT NOT OVER THE ROOF. CONTACT INFO/CASE ID # CASE # INSTALLER CONTACT INFO: NETMETERDOCS@CRSOLARENERGY.COM LUCIA & JOSE MENA 5.78 KW20696 JAGUAR TERRACE LAKEVILLE MN 55044• ALL PLANS FOLLOWS NEC CODES & 2021 MN BUILDING CODES• DISCONNECT AND PRODUTCTION METER SHALL BE INSTALLED WITHIIN 10 FT OF BI DIRECTIONAL UTILITY METER, OR BE PROPERLY LABLED WITH DIRECTIONAL MAPPING Jaguar Terrace LEGEND 1 LINEUL APPROVED INVERTER RATINGS @ STC A B C D MODEL: MAX POWER OUTPUT @STC: RATED AC VOLTAGE: SOLAR BREAKER OR FUSES SIZES: LUCIA & JOSE MENA 5.78 KW20696 JAGUAR TERRACE LAKEVILLE MN 55044 PV MODULES DETAILS @ STC MANUFACTURER: MODULE RATING: Q-CELL 340 SOLAREDGE SE6000 6000 24040 A B C D WIRE SIZING CHART 1) 2) 3) 6) 7) (4) #10 THWN (1) #10 GROUND IN 3/4" EMT (2) 12/2 MC CABLE WITH GROUND (4) #10 PV-TYPE USE-2 (POS, NEG)(1) #6 BARE CU (GROUND) (3) #8 THWN (1) #10 GROUND IN 3/4" EMT OR 3/4" RIDGE OR 3/4" SEAL-TIGHT (3) #8 THWN (1) #10 GROUND IN 3/4" EMT OR 3/4" RIDGE OR 3/4" SEAL-TIGHT DESIGNER: JM DATE: 8/16/2021 STRING DETAILS: STRING 1: 9 STRING 2: 8 DESIGN AND SITE MEETS NEC CONTACT CR SOLAR @: NETMETERDOCS@CRSOLARENERGY.COM CASE# INVERTER(S) ARE UL1741 CERTIFIED 1 2 17 AC DC M TO 120/240V SINGLE PHASE UTILITY SERVICE UNDERGROUND FED TO EXISTING LOADS PoC/RPA 4) 1) 2) 3)4) 5) 5)8)6)7) E D C 8) MAIN SERVICE METER BI-DIRECTIONAL 120/240 200A 3WIRE EXISTING 100A MAIN PANELWITH 1/0 CU CONDUCTORS AND 100AMP MAIN BREAKER 3 WIRE. INTERCONNECTION WILL BE MADE IN ACCORDANCE WITH 705.12(A). AC 60A EATON DG322URB SAFETY SWITCH, 1PHASE, 240V, 2POLE SERVICE RATED, FUSED NEMA 3R OR EQUAL WITH 40A FUSES. SE6000SOLAREDGE INVERTER EQUIPPED WITH RAPID SHUTDOWN, UL1741 CERTIFIED. HOFFMAN A6R66 ENCLOSURE, NEMA 3R, SCREW COVER, 6" x 6" x 6", PAINTED, KOS. SOLADECK 0783-41. PV ROOF- MOUNT ENCLOSURE 2 STRINGS TOTALING 17 Q-CELL 340W, PV MODULESW/ 1 P370 OPTIMIZER PER MODULE 240V 1PHASE 6k 3 WIRE Visable-open type lockable and readily accessible AC disconnect installed with in 8' of utility meter 3 WIRE. 1PH 120/240 Utility owned AB E U 100A 40A ELEC. PHOTOS DESIGNER:JM DATE: 8/16/2021 LUCIA & JOSE MENA5.78 KW 20696 JAGUAR TERRACE LAKEVILLE MN 55044 DESIGNER: JM DATE: 8/16/2021 LABEL PLAN LABEL SPECIFICATIONS •ALL PLANS FOLLOWS NEC CODES •2015 IRC / 2020 NEC / 2015 IBC •2021 MN RESIDENTIAL BUILDING CODES CONTACT INFO/ ID # CASE # INSTALLER CONTACT INFO: DALLAS@CRSOLARENERGY.COM 04407721 LUCIA & JOSE MENA 5.78 KW 20696 JAGUAR TERRACE LAKEVILLE MN 5504 4" 2"4" 6" 1" 3.75" 6.5" 1" 6.5" 1" 3.75" 2" .75" 4" 5.5" 1.75" 4" 1" 4" 1" 55 WEST 500 SOUTH, HEBER CITY, UT 84032 T 925.787.3067 U RIGHTANGLEENG.COM August 17, 2021 CR Solar LLC 2463 N Hillfield Rd Layton, UT 84041 RE: Structural Roof Evaluation for the Mena Residence: 20696 Jaguar Terrace, Lakeville, Minnesota As per your request, we have evaluated the roof structure under the proposed solar panel array. The information used to evaluate this structure was gathered by CR Solar on behalf of Right Angle Engineering. The roof structure consists of pre-manufactured trusses spaced at 24” on center. The roof material consists of asphalt shingles. The design criteria used to analyze this structure are listed above and included with this letter. The adopted building codes in this jurisdiction are: the 2018 International Building Code, the 2018 International Existing Building Code, and ASCE 7-16. International Existing Building Code (IEBC) 2018 section 806.2 indicates that alterations to an existing building that results in less than a 5% increase in the total stress may be performed without a structural evaluation of the existing building. As demonstrated in the attached calculations, the additional weight of the solar panels will be less than 5% increase in the gravity loading and the stress on the existing roof framing. Based on our assessment we have determined that the existing roof framing will safely and adequately support the additional loads imposed by the solar panels without reinforcement. In order for the loads to be evenly distributed, the roof attachments should be staggered and spread evenly throughout the panel array. Attachment points should be spaced at a maximum of 48” on center. The racking system should be installed per the manufacture’s specifications. There should be a minimum of 48 Unirac Flashloc attachment points to the roof. Each attachment should have a 5/16” or 18/8 SS lag screw with 2.5” minimum penetration centered on each truss top chord or rafter. Waterproofing around the roof penetrations is the responsibility of others. Right Angle Engineering assumes no responsibility for improper installation of the solar panels. Regards, Robert D Smythe, P.E. Right Angle Engineering 8/17/21 Design Criteria: Design Wind Speed (ASD)- 115 mph Ground Snow Load- 50 psf Risk Category- II Exposure category- C 2 Design Criteria: Design Wind Speed (3 second gust) 115 mph Exposure Category C Risk Category 2 Mean Roof Height 30 ft Roof Type Gable Roof Building Type enclosed Roof Dead Load- ASCE Table C3-1 Asphalt Shingles 2 psf 5/8" Plywood Sheathing 2 psf Roof Framing 4 psf Insulation 3.85 psf Gypsum sheathing 2 psf Solar Panel Array 3 psf Dead Load Without Panels 13.85 psf Dead Load With Solar panels 16.85 psf Roof Live Load Existing Roof Live Load 20 psf ASCE 7-16 Table 4.3-1 Roof Live Load with Solar Panels 0 psf 2018 IBC 1607.13.5.1 Roof Snow Load-ASCE 7-16 Ground Snow Load (pg) 50 psf Section 7.2 Exposure Factor (Ce) 0.9 Table 7.3-1 Thermal Factor (Ct) 1.1 Table 7.3-2 Importance Factor (Is) 1 Table 1.5-2 Flat Roof Snow Load (Pf) 35 Equation 7.3-1 Slippery surface Slope Factor (Cs) 0.87 Figure 7-2 Nonslippery Surface Slope Factor (Cs) 1 Figure 7-2 Roof Snow Load 35 psf Equation 7.4-1 Reduced Roof Snow Load (Slippery Surface) 30 psf Equation 7.4-1 Load Combinations - ASCE 7-16 Section 2.4.1 Without Solar Panels With Solar panels D + Lr 33.8 psf 16.8 psf D + S 48.5 psf 46.9 psf 3 Solar Array 1- West Roof Slope 18 degrees Number of panels 8 Panel Area 140 ft^2 Wind Calculations- ASCE 7-16 GCp Zone 1 -1 Figure 30.3-(2A-5B) GCp Zone 2 -1.8 Figure 30.3-(2A-5B) GCp Zone 3 -2.8 Figure 30.3-(2A-5B) Gcpi 0.18 Table 26.13-1 Velocity Pressure (qh) 28.2 psf qh= .00256KhKhtKdV^2 Equation 26.10-1 Kh 0.98 Table 26.10-1 Kht 1 Equation 26.8-1 Kd 0.85 Table 26.6-1 Designed wind pressure (P) psf Equation 30.8-1 P= qh(GCh) - (GChi)) Zone 1 Pressure (P) -33.3 psf Zone 2 Pressure (P) -55.8 psf Zone 3 Pressure (P) -84 psf Roof Connection Shear Capacity 190 lbs NDS 2015 Table 12K Shear tributary area 18.6 ft^2 Pullout Capacity 266 lbs/in Lag screw embedment 2.5 in Total pullout capacity 665 lbs NDS 2015 Table 12.2A Pullout max tributary area 11.9 ft^2 Factor of Safety 2.21 Minimum number of connections 24 Beam Stress IEBC 2018 Section 806.2 Beam Span 13 ft Spacing 2 ft Roof Framing type pre-manufactured trusses Panel Orientation landscape Number of Panels per rafter 2 Panel distance from eave 5 Without Solar Panels With Solar Panels Percent Increase Bending Moment 2049.1 ft-lbs 2114.6 ft-lbs 103.2% Less than 105% Vertical Reaction (V1) 630.5 lbs 628 lbs 99.6% Less than 105% Vertical Reaction (V2) 630.5 lbs 574.58 lbs 91.1% Less than 105% 4 Solar Array 2- South Roof Slope 18 degrees Number of panels 9 Panel Area 157.5 ft^2 Wind Calculations- ASCE 7-16 GCp Zone 1 -0.9 Figure 30.3-(2A-5B) GCp Zone 2 -1.7 Figure 30.3-(2A-5B) GCp Zone 3 -2.6 Figure 30.3-(2A-5B) Gcpi 0.18 Table 26.13-1 Velocity Pressure (qh) 28.2 psf qh= .00256KhKhtKdV^2 Equation 26.10-1 Kh 0.98 Table 26.10-1 Kht 1 Equation 26.8-1 Kd 0.85 Table 26.6-1 Designed wind pressure (P) psf Equation 30.8-1 P= qh(GCh) - (GChi)) Zone 1 Pressure (P) -30.5 psf Zone 2 Pressure (P) -53 psf Zone 3 Pressure (P) -78.4 psf Lag Screw Connection Shear Capacity 190 lbs NDS 2015 Table 12K Shear tributary area 18.6 ft^2 Pullout Capacity 266 lbs/in Lag screw embedment 2.5 in Total pullout capacity 665 lbs NDS 2015 Table 12.2A Pullout max tributary area 12.5 ft^2 Factor of Safety 2.11 Minimum number of connections 24 Beam Stress IEBC 2018 Section 806.2 Beam Span 12 ft Spacing 2 ft Roof Framing type pre-manufactured trusses Panel Orientation landscape Number of Panels per rafter 3 Panel distance from eave 1 Without Solar Panels With Solar Panels Percent Increase Bending Moment 1746 ft-lbs 1784.3 ft-lbs 102.2% Less than 105% Vertical Reaction (V1) 582 lbs 602.8 lbs 103.6% Less than 105% Vertical Reaction (V2) 582 lbs 535.6 lbs 92% Less than 105% ROJECTS True American Quality True American Brand Mission Solar Energy is headquartered in San Antonio, Texas, where we manufacture our modules. We produce American, high quality solar modules ensuring the highest in-class power output and best in-class reliability. Our product line is tailored for residential, commercial and utility applications. Every Mission Solar Energy solar module is certified and surpasses industry standard regulations, proving excellent performance over the long term. Demand the best. Demand Mission Solar Energy. 345WClass leading power output -0 to +3% Positive Power Tolerance Certified Reliability • Tested to UL 61730 & IEC Standards• PID resistant• Resistance to salt mist corrosion Advanced Technology • 6 Busbar • Passivated Emitter Rear Contact • Ideal for all applications Extreme Weather Resilience • Up to 5,600 Pa front load & 5,631 Pa back load • Tested load to UL 61730 • 40 mm frame BAA Compliant for Government Projects • Buy American Act • American Recovery & Reinvestment ActFrƒme-to-Frƒme Wƒrrƒnty Degradation guaranteed not to exceed 2% in year one and 0.58% annually from years two to 30 with 84.08% guaranteed in year 25. For more information visit www.missionsolar.com/warranty UL 61730 / IEC 61215 / IEC 61730 / IEC 61701 CERTIFICƒTIONS If you have questions or concerns about certification of our products in your area, please contact Mission Solar Energy. OF U.S. AND NON-U.S. PARTS C-SA2-MKTG-0025 REV 4 05/05/2021 www.missionsolar.com | info@missionsolar.com MSE PERC 60 MSE PERC 60Class Leading 340-350W C-SA2-MKTG-0025 REV 4 05/05/2021 www.missionsolar.com | info@missionsolar.com bƒsic dimensions [UNITS: MM/IN] 1748 40 1748 1054 1054 1748 Ø5.5 393 77 )URQW9LHZ)URQW9LHZ 6LGH9LHZ Ø7.0 0RXQWLQJ+ROH *URXQGLQJ+ROH [ 41.5 41.5 15.5 .28 3 68.8 68.8 1.6 68.8 ELECTRICƒL SPECIFICƒTION PRODUCT TYPE MSExxxSX5T (xxx = Pmax) Power Output Pmax Wp 340 345 350 Module Efficiency %18.5 18.7 19.0 Tolerance %0/+3 0/+3 0/+3 Short Circuit Current Isc V 10.86 10.92 10.97 Open Circuit Voltage Voc A 40.82 41.00 41.18 Rated Current Imp V 10.24 10.34 10.44 Rated Voltage Vmp V 33.20 33.37 33.52 Fuse Rating A 20 20 20 System Voltage V 1,000 1,000 1,000 TEMPERƒTURE COEFFICIENTS Normal Operating Cell Temperature (NOCT)44.43°C (±3.7%) Temperature Coefficient of Pmax -0.361%/°C Temperature Coefficient of Voc -0.262%/°C Temperature Coefficient of Isc 0.039%/°C OPERƒTING CONDITIONS Maximum System Voltage 1,000Vdc Operating Temperature Range -40°C (-40°F) to +85°C (185°F) Maximum Series Fuse Rating 20A Fire Safety Classification Type 1 Front & Back Load(UL Standard)Up to 5,600 Pa front and 5,631 Pa back load, Tested to UL 61730 Hail Safety Impact Velocity 25mm at 23 m/s MECHƒNICƒL DƒTƒ Solar Cells P-type mono-crystalline silicon Cell Orientation 60 cells (6x10) Module Dimension 1748mm x 1054mm x 40mm Weight 20.3 kg (44.8 lbs.) Front Glass 3.2mm, tempered, low-iron, anti-reflective Frame Anodized Encapsulant Ethylene vinyl acetate (EVA) Junction Box Protection class IP67 with 3 bypass-diodes Cable 1.0m, Wire 4mm2 (12AWG) Connector Staubli PV-KBT4/6II-UR and PV-KST4/6II-UR, MC4, Renhe 05-8 current-voltƒge curve MSE345SX5T: 345WP, 60 CELL SOLAR MODULE Current-voltage characteristics with dependence on irradiance and module temperature Voltƒge (v)Current (ƒ)Shipping informƒtion Container Feet Ship To Pallet Panels 345 W Bin 53’Most States 34 884 304.98 kW Double Stack CA 28 728 251.16 kW PALLET [26 PANELS] Weight1263 lbs.(573 kg) Height47.5 in(120.65 cm) Width46 in(116.84 cm) Length70.25 in(178.43 cm) certificƒtions ƒnd tests IEC 61215, 61730, 61701 UL 61730 Mission Solar Energy 8303 S. New Braunfels Ave., San Antonio, Texas 78235www.missionsolar.com | info@missionsolar.com FRONT VIEW SIDE VIEW REAR VIEW POWER OPTIMIZERsolaredge.com PV power optimization at the module-level Specifically designed to work with SolarEdge inverters Up to 25% more energy Flexible system design for maximum space utilization Fast installation with a single bolt Next generation maintenance with module- level monitoring Meets NEC requirements for arc fault protection (AFCI) and Photovoltaic Rapid Shutdown System (PVRSS) Module-level voltage shutdown for installer and firefighter safety Superior efficiency (99.5%) Mitigates all types of module mismatch losses, from manufacturing tolerance to partial shading Power Optimizer For North America P320 / P340 / P370 / P400 / P405 / P505 25 YEARWARRANTY © SolarEdge Technologies Ltd. All rights reserved. SOLAREDGE, the SolarEdge logo, OPTIMIZED BY SOLAREDGE are trademarks or registered trademarks of SolarEdge Technologies, Inc. All other trademarks mentioned herein are trademarks of their respective owners. Date: 08/2019/V02/ENG NAM. Subject to change without notice. (6) For detailed string sizing information refer to: http://www.solaredge.com/sites/default/files/string_sizing_na.pdf(7) It is not allowed to mix P405/P505 with P320/P340/P370/P400 in one string(8) A string with more than 30 optimizers does not meet NEC rapid shutdown requirements; safety voltage will be above the 30V requirement(9) For SE14.4KUS/SE43.2KUS: It is allowed to install up to 6,500W per string when 3 strings are connected to the inverter (3 strings per unit for SE43.2KUS) and when the maximum power difference between the strings is up to 1,000W(10) For SE30KUS/SE33.3KUS/SE66.6KUS/SE100KUS: It is allowed to install up to 15,000W per string when 3 strings are connected to the inverter (3 strings per unit for SE66.6KUS/SE100KUS) and when the maximum power difference between the strings is up to 2,000W Power Optimizer For North America P320 / P340 / P370 / P400 / P405 / P505 Optimizer model (typical module compatibility) P320 (for 60-cell modules) P340 (for high-power 60-cell modules) P370 (for higher- power60 and 72-cellmodules) P400 (for 72 & 96-cell modules) P405 (for thin film modules) P505 (for highercurrent modules) INPUT Rated Input DC Power(1)320 340 370 400 405 505 W Absolute Maximum Input Voltage (Voc at lowest temperature) 48 60 80 125(2)87(2)Vdc MPPT Operating Range 8 - 48 8 - 60 8 - 80 12.5 - 105 12.5 - 87 Vdc Maximum Short Circuit Current (Isc) 11 10.1 14 Adc Maximum DC Input Current 13.75 12.5 17.5 Adc Maximum Efficiency 99.5 % Weighted Efficiency 98.8 98.6 % Overvoltage Category II OUTPUT DURING OPERATION (POWER OPTIMIZER CONNECTED TO OPERATING SOLAREDGE INVERTER) Maximum Output Current 15 Adc Maximum Output Voltage 60 85 Vdc OUTPUT DURING STANDBY (POWER OPTIMIZER DISCONNECTED FROM SOLAREDGE INVERTER OR SOLAREDGE INVERTER OFF) Safety Output Voltage per Power Optimizer 1 ± 0.1 Vdc STANDARD COMPLIANCE EMC FCC Part15 Class B, IEC61000-6-2, IEC61000-6-3 Safety IEC62109-1 (class II safety), UL1741 Material UL94 V-0 , UV Resistant RoHS Yes INSTALLATION SPECIFICATIONS Maximum Allowed System Voltage 1000 Vdc Compatible inverters All SolarEdge Single Phase and Three Phase inverters Dimensions (W x L x H)129 x 153 x 27.5 / 5.1 x 6 x 1.1 129 x 153 x 33.5 / 5.1 x 6 x 1.3 129 x 159 x 49.5 / 5.1 x 6.3 x 1.9 129 x 162 x 59 / 5.1 x 6.4 x 2.3 mm / in Weight (including cables)630 / 1.4 750 / 1.7 845 / 1.9 1064 / 2.3 gr / lb Input Connector MC4(3)Single or dual MC4(3)(4)MC4(3) Input Wire Length 0.16 / 0.52 m / ft Output Wire Type / Connector Double Insulated / MC4 Output Wire Length 0.9 / 2.95 1.2 / 3.9 m / ft Operating Temperature Range(5) -40 - +85 / -40 - +185 ˚C / ˚F Protection Rating IP68 / NEMA6P Relative Humidity 0 - 100 % (1) Rated power of the module at STC will not exceed the optimizer “Rated Input DC Power”. Modules with up to +5% power tolerance are allowed(2) NEC 2017 requires max input voltage be not more than 80V(3) For other connector types please contact SolarEdge(4) For dual version for parallel connection of two modules use the P405. In the case of an odd number of PV modules in one string, installing one P405 dual version power optimizer(5) For ambient temperature above +85°C / +185°F power de-rating is applied. Refer to Power Optimizers Temperature De-Rating Technical Note for more details. PV System Design Using a SolarEdge Inverter(6)(7) Single Phase HD-Wave Single phase Three Phase 208V Three Phase 480V Minimum String Length (Power Optimizers) P320, P340, P370, P400 8 10 18P405 / P505 6 8 14Maximum String Length (Power Optimizers)25 25 50(8) Maximum Power per String 5700 (6000 with SE7600-US - SE11400-US)5250 6000(9)12750(10)W Parallel Strings of Different Lengths or Orientations Yes Certificate of Compliance Certificate:2550613 Master Contract:243363 Project:2599697 Date Issued:February 5, 2013 DQD 507 Rev. 2012-05-22 Page: 1 Issued to: SolarEdge Technologies 1A Abba Eban St Harzeliya, 46733 Israel Attention: Meir Adest The products listed below are eligible to bear the CSA Mark shown with adjacent indicators 'C' and 'US' for Canada and US or with adjacent indicator 'US' for US only or without either indicator for Canada only. Sarah Ugolini Issued by:Sarah Ugolini PRODUCTS CLASS 5311 09 - POWER SUPPLIES - Distributed Generation Power Systems Equipment CLASS 5311 89 - POWER SUPPLIES - Distributed Generation - Power Systems Equipment - Certified to U.S. Standards Photovoltaic Integrated Power Optimizer, Model OPJxxx-LV where xxx represents the wattage up to amaximum value of 330. Notes: Optimizer is certified as a component to be used in conjunction with a certified/listed photovoltaic modulewhere the suitability is to be evaluated in the end application. APPLICABLE REQUIREMENTS CSA-C22.2 No. 107.1-01 - General Use Power Supplies (Reaffirmed 2006) UL Std. No. 1741 - Inverters, Converters, Controllers and Interconnection System Equipment for Use withDistributed Energy Resources 2nd Ed. (Jan., 2010) UL Outline of Investigation 3730 - Outline of Investigation for Photovoltaic Junction Boxes INVERTERSsolaredge.com Optimized installation with HD-Wave technology Specifically designed to work with power optimizers Built-in module-level monitoring Outdoor and indoor installation Optional: Revenue grade data, ANSI C12.20 Class 0.5 (0.5% accuracy) Record-breaking efficiency Fixed voltage inverter for longer strings Integrated arc fault protection and rapid shutdown for NEC 2014 and 2017, per article 690.11 and 690.12 Extremely small UL1741 SA certified, for CPUC Rule 21 grid compliance Single Phase Inverter with HD-Wave Technology for North America SE3000H-US / SE3800H-US / SE5000H-US / SE6000H-US / SE7600H-US / SE10000H-US / SE11400H-US 12-25 YEARWARRANTY SE3000H-US SE3800H-US SE5000H-US SE6000H-US SE7600H-US SE10000H-US SE11400H-US OUTPUT Rated AC Power Output 3000 3800 @ 240V3300 @ 208V 5000 6000 @ 240V5000 @ 208V 7600 10000 11400 @ 240V10000 @ 208V VA Maximum AC Power Output 3000 3800 @ 240V3300 @ 208V 5000 6000 @ 240V5000 @ 208V 7600 10000 11400 @ 240V10000 @ 208V VA AC Output Voltage Min.-Nom.-Max. (211 - 240 - 264)Vac AC Output Voltage Min.-Nom.-Max. (183 - 208 - 229)----Vac AC Frequency (Nominal)59.3 - 60 - 60.5(1)Hz Maximum Continuous Output Current @240V 12.5 16 21 25 32 42 47.5 A Maximum Continuous Output Current @208V -16 -24 --48.5 A GFDI Threshold 1 A Utility Monitoring, Islanding Protection, Country Configurable Thresholds Yes INPUT Maximum DC Power @240V 4650 5900 7750 9300 11800 15500 17650 W Maximum DC Power @208V -5100 -7750 --15500 W Transformer-less, Ungrounded Yes Maximum Input Voltage 480 Vdc Nominal DC Input Voltage 380 400 Vdc Maximum Input Current @240V(2)8.5 10.5 13.5 16.5 20 27 30.5 Adc Maximum Input Current @208V(2)-9 -13.5 --27 Adc Max. Input Short Circuit Current 45 Adc Reverse-Polarity Protection Yes Ground-Fault Isolation Detection 600k Sensitivity Maximum Inverter Efficiency 99 99.2 % CEC Weighted Efficiency 99 99 @ 240V98.5 @ 208V % Nighttime Power Consumption < 2.5 W ADDITIONAL FEATURES Supported Communication Interfaces RS485, Ethernet, ZigBee (optional), Cellular (optional) Revenue Grade Data, ANSI C12.20 Optional(3) Rapid Shutdown - NEC 2014 and 2017 690.12 Automatic Rapid Shutdown upon AC Grid Disconnect STANDARD COMPLIANCE Safety UL1741, UL1741 SA, UL1699B, CSA C22.2, Canadian AFCI according to T.I.L. M-07 Grid Connection Standards IEEE1547, Rule 21, Rule 14 (HI) Emissions FCC Part 15 Class B INSTALLATION SPECIFICATIONS AC Output Conduit Size / AWG Range 1" Maximum / 14-6 AWG 1" Maximum /14-4 AWG DC Input Conduit Size / # of Strings / AWG Range 1" Maximum / 1-2 strings / 14-6 AWG 1" Maximum / 1-3 strings / 14-6 AWG Dimensions with Safety Switch (HxWxD)17.7 x 14.6 x 6.8 / 450 x 370 x 174 21.3 x 14.6 x 7.3 / 540 x 370 x 185 in / mm Weight with Safety Switch 22 / 10 25.1 / 11.4 26.2 / 11.9 38.8 / 17.6 lb / kg Noise < 25 <50 dBA Cooling Natural Convection Operating Temperature Range -13 to +140 / -25 to +60(4) (-40˚F / -40˚C option)(5)˚F / ˚C Protection Rating NEMA 4X (Inverter with Safety Switch) (1) For other regional settings please contact SolarEdge support (2) A higher current source may be used; the inverter will limit its input current to the values stated (3) Revenue grade inverter P/N: SExxxxH-US000NNC2(4) For power de-rating information refer to: https://www.solaredge.com/sites/default/files/se-temperature-derating-note-na.pdf(5) -40 version P/N: SExxxxH-US000NNU4 Single Phase Inverter with HD-Wave Technology for North America SE3000H-US / SE3800H-US / SE5000H-US / SE6000H-US/ SE7600H-US / SE10000H-US / SE11400H-US © SolarEdge Technologies, Inc. All rights reserved. SOLAREDGE, the SolarEdge logo, OPTIMIZED BY SOLAREDGE are trademarks or registered trademarks of SolarEdge Technologies, Inc. All other trademarks mentioned herein are trademarks of their respective owners. Date: 03/2019/V01/ENG NAM. Subject to change without notice. Roof Mount System Strength Tested All components evaluated for superior structural performance. PE Certified Pre-stamped engineering letters available in most states. Class A Fire Rating Certified to maintain the fire resistance rating of the existing roof. Design Software Online tool generates a complete bill of materials in minutes. Integrated Grounding UL 2703 system eliminates separate module grounding components. 20 Year Warranty Twice the protection offered by competitors. Built for solar’s toughest roofs. IronRidge builds the strongest roof mounting system in solar. Every component has been tested to the limit and proven in extreme environments. Our rigorous approach has led to unique structural features, such as curved rails and reinforced flashings, and is also why our products are fully certified, code compliant and backed by a 20-year warranty. Datasheet © 2014 IronRidge, Inc. All rights reserved. Visit www.ironridge.com or call 1-800-227-9523 for more information. Version 1.42 XR Rails Attachments Clamps & Grounding Datasheet Design Assistant Go from rough layout to fully engineered system. For free. Go to IronRidge.com/rm MacBook Pro NABCEP Certified Training Earn free continuing education credits, while learning more about our systems. Go to IronRidge.com/training Free Resources XR100 Rail The ultimate residential solar mounting rail. • 8’ spanning capability • Heavy load capability • Clear & black anod. finish Internal Splices All rails use internal splices for seamless connections. • Self-tapping screws • Varying versions for rails • Grounding Straps offered FlashFoot Anchor, flash, and mount with all-in-one attachments. • Ships with all hardware • IBC & IRC compliant • Certified with XR Rails Slotted L-Feet Drop-in design for rapid rail attachment. • High-friction serrated face • Heavy-duty profile shape • Clear & black anod. finish Standoffs Raise flush or tilted systems to various heights. • Works with vent flashing • Ships pre-assembled • 4” and 7” Lengths Tilt Legs Tilt assembly to desired angle, up to 45 degrees. • Attaches directly to rail • Ships with all hardware • Fixed and adjustable End Clamps Slide in clamps and secure modules at ends of rails. • Mill finish & black anod. • Sizes from 1.22” to 2.3” • Optional Under Clamps Grounding Mid Clamps Attach and ground modules in the middle of the rail. • Parallel bonding T-bolt • Reusable up to 10 times • Mill & black stainless T-Bolt Grounding Lugs Ground system using the rail’s top slot. • Easy top-slot mounting • Eliminates pre-drilling • Swivels in any direction Accessories Provide a finished and organized look for rails. • Snap-in Wire Clips • Perfected End Caps • UV-protected polymer XR10 Rail A low-profile mounting rail for regions with light snow. • 6’ spanning capability • Moderate load capability • Clear & black anod. finish XR1000 Rail A heavyweight mounting rail for commercial projects. • 12’ spanning capability • Extreme load capability • Clear anodized finish LOW PROFILE QUICKBOLT WITH 3” MICROFLASHING® FOR ASPHALT SHINGLE ROOFS PATENT # 8448407 17667SS 17664, 17666 AHJ CONDENSED PERMIT PACKAGE 2019 Version 3 A DIVISION OF QUICKSCREWS INTERNATIONAL CORP 35830 Las Positas Road, Livermore CA 94551 | 3948 Airway Drive, Rock Hill SC 29732 Phone: (844) 671-6045 | Fax: (800) 689-7975 | www.quickbolt.com QuickBOLT is a division of Quickscrews International Corp. SPEC SHEET Part #Box Quantity 17664 5.25” Bolts (10) 17666 3” Microflashing® (10); 5.25” Bolts (10) 17667SS 3” Microflashing® (25); 5.25” Bolts (25); L-Foot (25); 5/16” Serrated Hex Flange Nuts (25) Microflashing® 4 5830 Las Positas Road, Livermore CA 94551 | 3948 Airway Drive, Rock Hill SC 29732 Phone: (844) 671-6045 | Fax: (800) 689-7975 | www.quickbolt.com QuickBOLT is a division of Quickscrews International Corp. 55830 Las Positas Road, Livermore CA 94551 | 3948 Airway Drive, Rock Hill SC 29732 Phone: (844) 671-6045 | Fax: (800) 689-7975 | www.quickbolt.com QuickBOLT is a division of Quickscrews International Corp. STAINLESS STEEL L-FOOT Part #Box Quantity 15894SS 10 SS L-Foot 5830 Las Positas Road, Livermore CA 94551 | 3948 Airway Drive, Rock Hill SC 29732Phone: (844) 671-6045 | Fax: (800) 689-7975 | www.solarroofhook.comSolarRoofHook is a division of Quickscrews International Corp. 15894SS 15794SS 4mm Thick 6 5830 Las Positas Road, Livermore CA 94551 | 3948 Airway Drive, Rock Hill SC 29732 Phone: (844) 671-6045 | Fax: (800) 689-7975 | www.quickbolt.com QuickBOLT is a division of Quickscrews International Corp. INSTALL INSTRUCTIONS 1 2 3 4 5 RECOMMENDED MATERIALS • Rafter locator • Chalk or a crayon • Drill with a 3/16” drill bit • MFG approved sealant • M6 deep socket hex driver • 1/2” wrench INSTALLATION INSTRUCTIONS 1. Locate the rafter and predrill the hole 2. Fill the predrilled hole with MFG approved sealant 3. Place the Microflashing® and drive the bolt until it compresses 4. Insert the L-Foot 5. Insert the nut and tighten until secure 22 5830 Las Positas Road, Livermore CA 94551 | 3948 Airway Drive, Rock Hill SC 29732 Phone: (844) 671-6045 | Fax: (800) 689-7975 | www.quickbolt.com QuickBOLT is a division of Quickscrews International Corp. CERTIFICATE OF COMPLIANCE Certificate Number 20180725-E493748 Report Reference E493748-20170817 Issue Date 2018-JULY-25 Bruce Mahrenholz, Director North American Certification Program UL LLC Any information and documentation involving UL Mark services are provided on behalf of UL LLC (UL) or any authorized licensee of UL. For questions, please contact a local UL Customer Service Representative at http://ul.com/aboutul/locations/ Page 1 of 2 Issued to: SolarRoofHook, a Division of Quickscrews International Corp 5830 Las Positas Rd, Livermore CA 94551 This is to certify that representative samples of COMPONENT - MOUNTING SYSTEMS, MOUNTING DEVICES, CLAMPING DEVICES AND GROUND LUGS FOR USE WITH PHOTOVOLTAIC MODULES AND PANELS Refer to Addendum Page for Models/Product. Have been investigated by UL in accordance with the Standard(s) indicated on this Certificate. Standard(s) for Safety: UL 2703 Standard for Mounting Systems, Mounting Devices, Clamping/Retention Devices, and Ground Lugs for Use with Flat-Plate Photovoltaic Modules and Panels. Additional Information: See the UL Online Certifications Directory at www.ul.com/database for additional information Only those products bearing the UL Certification Mark should be considered as being covered by UL's Certification and Follow-Up Service. The UL Recognized Component Mark generally consists of the manufacturer’s identification and catalog number, model number or other product designation as specified under “Marking” for the particular Recognition as published in the appropriate UL Directory. As a supplementary means of identifying products that have been produced under UL’s Component Recognition Program, UL’s Recognized Component Mark: , may be used in conjunction with the required Recognized Marks. The Recognized Component Mark is required when specified in the UL Directory preceding the recognitions or under “Markings” for the individual recognitions. Recognized components are incomplete in certain constructional features or restricted in performance capabilities and are intended for use as components of complete equipment submitted for investigation rather than for direct separate installation in the field. The final acceptance of the component is dependent upon its installation and use in complete equipment submitted to UL LLC. Look for the UL Certification Mark on the product. UL CERTIFICATION 235830 Las Positas Road, Livermore CA 94551 | 3948 Airway Drive, Rock Hill SC 29732 Phone: (844) 671-6045 | Fax: (800) 689-7975 | www.quickbolt.com QuickBOLT is a division of Quickscrews International Corp. CERTIFICATE OF COMPLIANCE Certificate Number 20180725-E493748 Report Reference E493748-20170817 Issue Date 2018-JULY-25 Bruce Mahrenholz, Director North American Certification Program UL LLC Any information and documentation involving UL Mark services are provided on behalf of UL LLC (UL) or any authorized licensee of UL. For questions, please contact a local UL Customer Service Representative at http://ul.com/aboutul/locations/ Page 2 of 2 This is to certify that representative samples of the product as specified on this certificate were tested according to the current UL requirements. Models/Product USR – Component, Roof Mounting Hook Units, Models 15891 15893 15987 16000 16988 16990 16991 16993 17508 17509 17510 17511 17512 17513 17514 17515 17516 17517 17518 17519 17520 17521 17522 17523 17524 17525 17526 17527 17536 17537 17538 17539 17540 17541 17542 17543 17544 17545 17546 17547 17548 17549 17550 17551 17552 17553 17554 17555 17556 17558 17559 17560 17568 17569 17570 17571 17572 17573 17574 17575 17576 17577 17578 17579 17580 17585 17586 17587 17588 17589 17592 17596 17600 17601 17606 17607 17608 17609 17610 17611 17612 17613 17614 17615 17616 17617 17618 17620 17621 17622 17623 17624 17625 17626 17627 17628 17629 17630 17631 17632 17633 17636 17637 17638 17639 17642 17643 17646 17647 17648 17649 17650 17651 17659 17664 17667 17669 17670 17671 17672 17673 17678 17679 17680 17681 17686 17687 17688 17689 17700 17701 17702 17703 17704 17705 17706 17707 17708 17709 17710 17711 17712 17717 17718 17759 15891-10 15891BLK-10 15987A 15987B 17667SS 17672SS 17680SS 17688SS 17713SS 17720 17721SS 17723 17724SS 17726 17727SS 17729 17730SS 15894SS 15891SS 15987BSS. 24 5830 Las Positas Road, Livermore CA 94551 | 3948 Airway Drive, Rock Hill SC 29732 Phone: (844) 671-6045 | Fax: (800) 689-7975 | www.quickbolt.com QuickBOLT is a division of Quickscrews International Corp. AZ TEST RESULTS Part# Box Quantity Screw Size 17540 20 Hooks Not Included 17541 1 Hook Not Included 17542 20 Hooks & 40 Screws #14 X 3" 17543 1 Hook & 2 Screws #14 X 3" 17608 20 Hooks & 40 Screws 5/16" X 3" 17609 1 Hook & 2 Screws 5/16" X 3" **Old Part # FTRH90 Letter A B C D E Description Mountinq Screw Holes Rail Slot Size Lenqth of Roof Hook Rail Heiqht From Finised Roof Thickness f 15mm B Rai I Slot Accepts a· or 3/8" Bolts 5/1 Size/Length 9mm 10mmx46mm 286mm 70mm-108mm 5mm 120mm [ 90° 178mm Rev2 D 81.82mm 5830 Las Positas Road, Livermore, California 94551 I 3948 Airway Drive, Rock Hill, South Carolina 29732 Phone: (844)-671-6045 I Fax: (800)-689-7975 I www.solarroofhook.com SolarRoofHook is a division of Quickscrews International Corp. Mr. Rick GentryQuickscrews InternationalSolarRoofHook.com5830 Las Positas RoadLivermore, CA 94551 Subject: Uplift and Lateral Load Test of QS #17664 (Kit #17667) 5/16" x 5-1/4" Low ProfileQuickBolt with 3" OD EPDM Compression Washer and Aluminum L-Foot Dear Mr. Gentry, Per our service agreement, PNL has tested the 5/16 in. x 5-1/4 in. Low Profile QuickBolt andAluminum L-Foot assembly. The tests performed were a tensile load (uplift) test and a shear load(lateral load) test. A total of three Low Profile QuickBolt and L-Foot assemblies were tested for each load type. The samples submitted were the 5/16 in. x 5-1/4 in. Low Profile QuickBolt and Aluminum L-Foot from Kit #17664 with a 5/16 in. Hex Serrated Flange Nut 18-8, Part #15879. The submitted sample materials are the same as the parts in Part #17666 and #17667. INITIAL SETUP The Low Profile QuickBolt and L-Foot assembly was assembled in our laboratory and was directly attached to a Douglas Fir 2"x4" through a 12 mm Birch plywood base. A 3/16" dia hole was predrilled into the rafter and plywood fixture and the Low Profile QuickBolt was installed using a 3" OD EPDM, Type 304 Stainless Compression Washer against the plywood base. Each 2"x4" rafter was connected to the plywood using two screws at each end of the 12 in. long 2"x4" (See Pages 3 - 5 for Photos). TEST PROCEDURE Tensile Load (Uplift) Test A total of three tests were conducted for tensile load (uplift) capacity on an Instron Universal Test Machine (UTM). The test samples were rigidly attached to the test machine using clamps and a tensile load was applied to the Low Profile QuickBolt. The tensile load was applied at a constant crosshead rate of 0.09 in./min. without shock until failure. The load and displacement at failure were recorded and the failure mode was documented in photos. The average tensile load of the 5/16" x 5- 1/4" QuickBolt with 3" OD EPDM Compression Washer and Aluminum L-Foot was 3626 lbf. Additional details and photographs are supplied on page 3. Shear Load (Lateral Load) Test A total of three tests were conducted for shear load (lateral load) capacity on a UTM. The testsamples were rigidly attached to the test machine using clamps so that a compressive load could be Page 1 of 5 255830 Las Positas Road, Livermore CA 94551 | 3948 Airway Drive, Rock Hill SC 29732 Phone: (844) 671-6045 | Fax: (800) 689-7975 | www.quickbolt.com QuickBOLT is a division of Quickscrews International Corp. applied to the L-Hook in a direction parallel to the 2"x4" rafters. The shear load was applied at aconstant rate of 0.09 in./min. without shock until the roof hook until failure. The load anddisplacement at failure were recorded and the failure mode was documented in photos. The average compressive load of the 5/16" x 5-14" Low Profile QuickBolt with 3" OD EPDM Compression Washer and Aluminum L-Foot was 2238 lbf. Additional details and photographs are supplied on page 5. Respectfully Submitted, PHOENIX NATIONAL LABORATORIES, INC. __________________ Kyle Fleege, P.E. Project Manager PNL Ph: 602.431.8887kyle@pnltest.comwww.pnltest.com Page 2 of 5 2XWGRRU3KRWRYROWDLF(QFORVXUHV6HULHV (7/OLVWHGDQGODEHOHG 5HSRUW357-5HYLVHG0D\ · 8/7\SH5(GLWLRQ(OHFWULFDOHTXLSPHQWHQFORVXUHV · &6$&1R1HPD7\SH5 · &RQIRUPVWR8/6WDQGDUG · 9'&DPSV · 9$&DPSV · \HDUOLPLWHGZDUUDQW\ &RPSRVLWLRQ&HGDU5RRI6\VWHP %DVLF6SHFLILFDWLRQV 0DWHULDORSWLRQV · 3RZGHUFRDWHGJDXJHJDOYDQL]HGVWHHO  KRXUVVDOWVSUD\ · 6WDLQOHVVVWHHO 3URFHVV-6HDPOHVVGUDZ VWDPSHG )ODVKLQJ-´[´ +HLJKW-´ &DYLW\-&XELFLQFKHV $SSUR[LPDWHZHLJKW-OE %DVH3ODWH · )DVWHQHGWREDVHXVLQJWRJJOHIDVWHQLQJV\VWHP · URRIGHFNNQRFNRXWV · .QRFNRXWVL]HV  ´  ´DQG  ´ · ´PPVORWWHGGLQUDLO · *URXQG%ORFN DŽĚĞůƐĂǀĂŝůĂďůĞŝŶ'ƌĞLJ͕ůĂĐŬŽƌ^ƚĂŝŶůĞƐƐ^ƚĞĞů ^ŽůĂĞĐŬϬϳϵϵ-Ϯ^ ^ŽůĂĞĐŬϬϳϵϵ-' 3DVVWKURXJKDQGFRPELQHUNLWVDUHDYDLODEOHIRUHLWKHU $&RU'&DSSOLFDWLRQV ^ŽůĂĞĐŬϬϳϵϵ-ϱ' Ϭϳϵϵ^ĞƌŝĞƐDŽĚĞůƐ 'ƌŽƵŶĚdLJƉĞ 'ƌŽƵŶĚtŝƌĞ^ŝnjĞ Ϭϳϵϵ-Ϯ ϮWŽƐŝƟŽŶ'ƌŽƵŶĚ ϮͬϬ-ϭϰ Ϭϳϵϵ-ϱ ϱWŽƐŝƟŽŶ'ƌŽƵŶĚ ϭϰ-ϲ Ϭϳϵϵ- ƵĂů'ƌŽƵŶĚ ϭϰ-ϴ 567&(QWHUSULVHV,QF (DX&ODLUH:, -- VDOHV#VRODGHFNFRP Report No. 3171411PRT-002 RSTC Enterprises, Inc. Page 2 of 30 Issued: 30-Jan-2009 Revised: 7-May-2018 2.0 Product Description Product Electrical Combiner Box Brand name RSTC Enterprises The products covered by this report are a Combiner box (DC and AC power applications) for use with a up to four photovoltaic array inputs, and an output of a single DC/AC source. Description Product has been tested and found compliant for installation at 14 degrees and above. The product is intended for installation on composite, metal, or rubber roofing. 0783-41 , 0786-41 , 0760-41 AD, 0766-41 AD. Models 0799-followed by 2, 5, D, E or EP; followed by B, G or S. Models 0783-41 and 0786-41 are similar except for the use of the negative terminal block in unit. The 0783-41 model has its negative terminal block mounted to the enclosure in a stand- alone fashion with up to four inputs and one lug output, while the 0786-41 model has its negative terminals mounted to the DIN rail. Models 0760-41 AD and 0766-41 AD are identical except that Model 0766-41 AD has a 6" deep base for installation on tile and slate roofs. Models 0760-41 AD and 0766-41 AD are similar to Models 0783-41 and 0786-41 except for component configuration (see section 4.0 for details) Model Similarity All models in the 0799 series are similar in design and construction except for the internal components. The configuration of the models are as follows: "2" is for a two position ground lug, "5" is for a five position ground lug, "D" is for a one position ground lug, "E" is for Enphase bulkheads and a supplementary protection device, "EP" is for Enphase bulkheads, "B" is for a black powder coated enclosure, "G" is for a grey powder coated enclosure, and "S" is for stainless steel enclosure. Models 0783-41, 0786-41 : 600VDC, 120A Ratings Models 0760-41 AD, 0766-41 AD: 600VDC, 120A / 240VAC, 60A Models 0799: 1 000VDC, 180A / 480VAC, 60A Other RatinQs Maximum Fuse Short Circuit Current = 1 0kA. Type 3R ED 16.3.15 (20-Apr-17) Mandatory 1.0 Reference and Address Report Number 3171411 PRT-002 I Original Issued: 30-Jan-2009 Revised: 7-May-2018 Inverters, Converters, Controllers And Interconnection System Equipment For Use With Standard(s) Distributed Energy Resources [UL 1741 :201 O Ed.2 +R:07Sep2016] Photovoltaic Combiners [CSA C22.2#290:2015 Ed.1] Aoolicant RSTC Enteq2rises, Inc. Manufacturer 1 RSTC Enterorises Inc. Address 2214 Heimstead Road Address 2214 Heimstead Road Eau Claire, WI 54703 Eau Claire, WI 54703 Country USA Country USA Contact Steve Capozzi Contact Steve Capozzi Phone (715) 830-9997 Phone (715) 830-9997 FAX (715) 830-9976 FAX (715) 830-9976 Email scaQozzi@rstcenterQrises.com Email scaQozzi@rstcenterQrises.com