Loading...
HomeMy WebLinkAboutLA195695 7066 183rd St W Permit Pack45 CANNOT HOOK TO CITY SEWER/WATER RESIDENTIAL BUILDING PERMIT APPLICATION PAGE 2 OFFICE USE ONLY BUILDING PERMIT TYPE REQUIRED INSPECTIONS SINGLE FAMILY DWELLING BUILDING DUPLEX AS BUILT TOWNHOUSE UNITS BUILDING FINAL DETACHED TOWN HOUSE UNIT DECK FOOTING CONDO FIREPLACE ACESSORY BUILDING FOOTING REROOF FOUNDATION RESIDE FRAMING PORCH FRAMING GARAGES INSULATION RES ADDN/REPAIR/RMDL DECK PORCH GARAGES LATH LOWER LEVEL FINISH LOWER LEVEL FINAL ADDITION OTHER FOUNDATION ONLY PORCH FOOTING MISCELLANEOUS POURED WALL DEMO SEPTIC TANK REMOVAL MOVED SITE MECHANICAL CITY BUILDING VALUATION: $AIR TEST FINAL BUILDING PERMIT FEES ROUGH-IN $PERMIT FEE PLUMBING $PLAN CHECK FINAL $SURCHARGE ROUGH-IN $METRO SAC METER SIZE $CITY WATER HOOKUP UNIT PRESSURE REDUCING VALVE $CITY SEWER HOOKUP UNIT SEWER/WATER $LANDSCAPE ESCROW SEWER/WATER $TREE ESCROW FINAL $MISC ESCROW STREET DRAINTILE $PLUMBING BUILDING INFORMATION $MECHANICAL TYPE OF CONSTRUCTION $SEWER WATER ZONING $OTHER CODE EDITION $TOTAL FIRE SUPPRESSION SYSTEM OCCUPANCY GROUP APPROVED BY: BUILDING INSPECTOR: Date: PLUMBING/MECHANICAL INSPECTOR: Date: COMMENTS: 20195 Holyoke Avenue, Lakeville, MN 55044 952-985-4400  952-985-4499 fax www.lakevillemn.gov Sewer & Water Tie Card Address:________________________________________ Contractor:______________________________________ Permit Number:__________________________________ Final Date:________________ Street Drain-Tile:______ Size of Water Service: 1” Comments: AIRTEST SANITARY OVER 20’/2 FITTINGS THIS CARD MUST BE COMPLETED AND ON-SITE AT TIME OF SEWER & WATER INSPECTION Secure door closed until deck is constructed with a separate permit. Concept Approval ONLY Subject to Field Inspection Inspector Date 2020 MN Bldg Code 09/10/2021dmathews BWPs Above UFER Ground -Provide 20' Rebar in footing and stub up near electrical service panel. 3' WSP 4' WSP 4' WSP 4' WSP 4' WSP 4' WSP 4' WSP 4' WSP 4' WSP PFH PFH 4' WSP 4' WSP 4' WSP 4' WSP Verify loads with girder truss specs, may require removal of top plates at bearing due to crushing. BWPs Above 8' LIB 8' LIB 8' LIB 8' LIB 2.75' WSP 8' LIB -Min. 15" clearance to any obstruction from center of W.C., 24" in front(typ). Date Certificate Post x Passive (No Fan) Active (With fan and monometer or other system monitoring device) Location (or future location) of Fan: Other Please Describe Here x R-15 x x R-20 x x R-20 x x 19+5 x x R-49 x R-49 x R-38 x R-38+5 x x Not applicable, all ducts located in conditioned space X x Not required per mech. code Passive Powered Interlocked with exhaust device. Describe: Input in BTUS: 44,000 Capacity in Gallons: Other, describe: AFUE or HSPF% 93% Cfm's " round duct OR " metal duct Not required per mech. code X Passive x Low: Other, describe: Low: Location of fan(s), describe: Cfm's 6 " Flex " metal duct Balanced Ventilation capacity in cfms: Capacity continuous ventilation rate in cfms: Total ventilation (intermittent + continuous) rate in cfms: 82 High: Energy Recover Ventilator (ERV) Capacity in cfms: High: Location of duct or system: Below Entire Slab Foundation Wall Perimeter of Slab on Grade Rim Joist (1st Floor) Rim Joist (2nd Floor+) Wall Ceiling, flat R-5 where required R10 Rigid Exterior, R10 Int closed cell R10 Rigid Exterior, R10 Int closed cell R5 Exterior, R19 Batts New Construction Energy Code Compliance Certificate Per R401.3 Certificate. A building certificate shall be posted on or in the electrical distribution panel. Mailing Address of the Dwelling or Dwelling Unit City Lakeville7066 183rd Street W Name of Residential Contractor MECHANICAL VENTILATION SYSTEM Describe any additional or combined heating or cooling systems if installed: (e.g. two furnaces or air source heat pump with gas back-up furnace): Combustion Air Select a Type Select Type Heat Recover Ventilator (HRV) Capacity in cfms: 192 MN License Number Brandl Anderson Homes BC604388 THERMAL ENVELOPE RADON CONTROL SYSTEM Type: Check All That Apply Insulation Location Total R-Value of all Types of InsulationNon or Not ApplicableFiberglass, BlownFiberglass, BattsFoam, Closed CellFoam Open CellMineral FiberboardRigid, Extruded PolystyreneRigid, IsocynurateAttic Residential Load Calculation Heating Loss Heating Gain Cooling Load 41678 13839 18,440 13 Location of duct or system: Rating or Size 50 Output in Tons:2 Efficiency SEER /EER Natural Gas Natural Gas Electric 13ACXN024 Fuel Type Manufacturer Lennox Lennox Model ML193UH045XE Average U-Factor (excludes skylights and one door ) U: 0.30 Solar Heat Gain Coefficient (SHGC): 0.30 R-value R-8 MECHANICAL SYSTEMS Make-up Air Select a Type Appliances Heating System Domestic Water Heater Cooling System Duct system air tightness: Heating or Cooling Ducts Outside Conditioned Spaces Ceiling, vaulted Bay Windows or cantilevered areas Floors over unconditioned area Describe other insulated areas Building envelope air tightness: Windows & Doors 000000Builders Associaton of Minnesota version 101014 40,000 X X 40,000 40,000 3000 3000 3000 40,000 40,000 13.33 13.33 1936 1936 .64 .64 .36 .36 4.8 2.5 NR 240 375 375 3154 473 473 160 80 09/02/21 X KP