HomeMy WebLinkAboutLA196459 Approved Solar Plans814 E 1475 N
Lehi, UT 84043
m: (309) 645-0999
Solar Professional Engineering Consulting admin@lucenteng.co
Everlight Solar
PO Box 930550
Verona, WI 53593
RE: Engineering Services
Hair Residence
16311 Fallbrook Dr, Lakeville, MN
7.67 kW System
Solo Job #1522343
To Whom It May Concern,
A. Assumptions from Field Observation provided by Everlight Solar
Roof Roof B
Roof Finish :Asphalt Shingle Asphalt Shingle
Roof Underlayment :OSB OSB
Roof Profile :Gable Gable
Roof Structural System :Metal Plate Trusses Metal Plate Trusses
Truss Top Chord/Setup :2 x 4 / Fink 2 x 4 / Fink
Chord/Rafter Wood Grade :Doug-Fir #2 or better Doug-Fir #2 or better
Truss/Rafter Spacing :24'' o.c.24'' o.c.
Roof Slope :33 deg 33 deg
Max Top Chord/Rafter Span :6.55 ft 6.55 ft
Bearing Wall Type : Convl Lt-Frame Constr CLFC
Foundation : Permanent Concrete Permanent Concrete
Stories : Two Single
B. Building Design Criteria
Code : 2018 IRC (ASCE 7-16) Risk Category : II
Roof Live Load : 20 psf (0 psf at panels) Occupancy Class : R-3
Ground Snow Load : 50 psf Roof Dead Load : 6.5 psf
Ult Wind Speed : 115 mph PV Dead Load : 3 psf
Exposure Category : B Total Dead Load : 9.5 psf
C. Summary of Existing Structure Results
Roof
The following structural design regarding the proposed alterations have been prepared from these
assumptions. The verification of the field observations is the responsibility of the contractor. Prior to
commencement of work, the contractor shall verify the framing sizes, spacings, and spans noted in the
sealed plans, calculations, and/or certification letter and notify the Engineer of Record of any
discrepancies.
After review of the field observations and based on our calculations and in accordance with the
applicable building codes and current industry standards, the existing roof structure supporting the
Lucent Engineering, P.C.
September 29, 2021
We have reviewed the following information regarding the solar panel installation for this project. Alterations to
these documents or plans shall not be made without direct written consent of the Engineer of Record.
- Adaquate to support the additional imposed loads. No structural upgrades are required.
D. Solar Panel Support Bracket Anchorage
1.
2. Manufacturer's Panel Bracket Connection to Roof Chord/Rafter Member:
Fastener : (1) 5/16'' Lag Screw per Bracket
NDS Withdrawl Value : 266 lbs/inch
Min. Thread Length and Pentration Depth : 2.5''
3.
4.
E. Overall Summary
Sincerely,
John H. Leesman, PE
License No. 59214
Limits of Scope of Work and Liablity
The existing structure is assumed to have been designed and constructed following appropriate codes at the
time of erection and assumed to have appropriated permits. The calculations performed are only for the roof
framing supporting the solar array installation referenced in the stamped plans and were completed according
to generally recognized structural analysis standards and procedures, professional engineering, and design
experience opinions and judgements. Existing deficiencies which are unknown or were not observed during
the time the site observation are not included in this scope of work. All solar panel modules, racking, and
mounting equipment shall be designed and installed per the manufacturer's approved installation
specifications. The Engineer of Record and the engineering consulting firm assume no responsibility for
misuse or improper installation. This analysis is not stamped for water leakage. Framing was determined on
information in provided plans and/or photos, along with engineering judgement. Prior to commencement of
work, the contractor shall verify the framing sizes, spacings, and spans noted in the stamped plans,
calculations, and/or certification letter and notify the Engineer of Record of any discrepancies prior to starting
construction. If during solar panel installation, the roof framing members appear unstable or deflect non-
uniformly, our office should be notified before proceeding with the installation. The contactor shall also verify
that there are no damage/deficiencies (i.e., dry rot, water damage, termite damage, framing
member/connection damage, etc.) to framing that was not addressed in the stamped plans, calculations,
and/or certification letter and notify the Engineer of Record of any concerns prior to starting construction.
Should you have any questions regarding this letter or if you require further information, do not hesitate to
contact me.
Considering the existing roof's slope, size, spacing, condition, and calculated loads, the panel
bracket supports shall be placed no greater than 48 in. o/c.
Panel supports connections shall be staggered to distribute load to adjacent trusses.
proposed alterations consisting of the solar array has been determined to be:
Solar panels shall be designed, mounted, and installed in accordance with the most recent
''Quickbolt Manual'', which can be found on the Quickbolt website (http://quickbolt.com).
Based on the information supplied to us at the time of this report, on the evaluation of the existing structure,
and solar array panel bracket connection, it is our opinion that the roof system will adequately support the
additional loads imposed by the solar array. This evaluation conforms to 2018 IRC and current industry
standards.
Dakota ElectricEverlight Solar Construction7369 Highway 13 WSavage, MN 55378License# BC771658833.786.4387 ext. 701CONTRACTOR INFORMATION:SITE INFORMATIONThomas Hair16311 Fallbrook DrLakeville, MN 55044 AC SYSTEM SIZE: 7.672 kW AC DC SYSTEM SIZE: 9.72 kW DCLat, 44.7128383Long, -93.1855731(27) Silfab SIL-360 NX mono PERC PVMODULES(14) AP Systems YC600 INVERTER(S)DATE:September 28, 2021PV01 COVER PAGEPV02 SITE PLANPV03 ROOF ATTACHMENTSPV04 MOUNTING DETAILPV05 LINE DIAGRAMPV06 LABELSPV07 PLACARDPV08 SITE PHOTOSCOVER PAGE - PV01 DRAWN BY: SoloCAD1.INSTALLATION OF SOLAR PHOTOVOLTAIC SYSTEM SHALL BE IN ACCORDANCE WITH NEC ARTICLE690, AND ALL OTHER APPLICABLE NEC CODES WHERE NOTED OR EXISTING.2.PROPER ACCESS AND WORKING CLEARANCE AROUND EXISTING AND PROPOSED ELECTRICALEQUIPMENT WILL COMPLY WITH NEC ARTICLE 110.3.ALL WIRES, INCLUDING THE GROUNDING ELECTRODE CONDUCTOR SHALL BE PROTECTED FROMPHYSICAL DAMAGE IN ACCORDANCE WITH NEC ARTICLE 2504.THE PV MODULES ARE CONSIDERED NON-COMBUSTIBLE; THIS SYSTEM IS UTILITY INTERACTIVE PERUL 1741 AND DOES NOT INCLUDE STORAGE BATTERIES OR OTHER ALTERNATIVE STORAGE SOURCES.5.ALL DC WIRES SHALL BE SIZED ACCORDING TO [NEC 690.8]6.DC CONDUCTORS SHALL BE WITHIN PROTECTED RACEWAYS IN ACCORDANCE WITH [NEC 690.31]7.ALL SIGNAGE TO BE PLACED IN ACCORDANCE WITH LOCAL JURISDICTIONAL BUILDING CODE.PHOTOVOLTAIC (PV) SYSTEM SPECIFICATIONSAERIAL VIEW:SHEET INDEX: EQUIPMENT: AC SYSTEM SIZE: 7.672 kW AC DC SYSTEM SIZE: 9.72 kW DC (27) Silfab SIL-360 NX mono PERC PV MODULES (14) AP Systems YC600 INVERTER(S) RACKING: IronRidge - 48" O.C.OCCUPANCY: R-3ZONING: RESIDENTIAL2020 NEC2020 MRC2020 MFC2020 MBCSTREET VIEW:GENERAL NOTESAPPLICABLE GOVERNING CODESSITE SPECIFICATIONS
JBJBACPVMSPMCDakota ElectricSITE INFORMATIONThomas Hair16311 Fallbrook DrLakeville, MN 55044 AC SYSTEM SIZE: 7.672 kW AC DC SYSTEM SIZE: 9.72 kW DCLat, 44.7128383Long, -93.1855731(27) Silfab SIL-360 NX mono PERC PVMODULES(14) AP Systems YC600 INVERTER(S)DATE:September 28, 2021Everlight Solar Construction7369 Highway 13 WSavage, MN 55378License# BC771658833.786.4387 ext. 701CONTRACTOR INFORMATION:EQUIPMENT LEGEND:INVERTERVISIBLE, LOCKABLE, LABELEDAC DISCONNECTMETER SOCKET(FOR UTILITY PV METER)UTILITY METERMAIN SERVICE PANELLCLOAD CENTERFIRE ACCESS PATHWAY (3' TYP)CINVPVACMSPMCOMBINER BOXPROPERTY LINEFRONT OF HOME16311 Fallbrook DrMP2PITCH: 33°AZIMUTH: 142°BATTBATTERY(IES)VISIBLE, LOCKABLE,LABELED AC DISCONNECTLOCATED WITHIN 10'OF UTILITY METERSUBSUB PANELSITE PLAN - PV02DRAWN BY: SoloCADMP1PITCH: 33°AZIMUTH: 142°91'-10"142'-6"
ROOF INFO:ROOF TYPEasphalt_shingleROOF FRAMINGmanufactured_trussRAFTER/TOP CHORD SIZE2x4RAFTER/TOP CHORD SPACING24"ATTACHMENT SPACING48JBJBACPVMSPMCEQUIPMENT INFORMATION:RAIL MANUFACTURERIronRidgeRAIL PART NUMBERXR-10ATTACHMENTSQuickbolt 2 (QB2)ATTACHMENT QTY52SPLICE QTY6MIDCLAMP QTY42ENDCLAMP QTY24ROOF INFO:Dakota ElectricSITE INFORMATIONThomas Hair16311 Fallbrook DrLakeville, MN 55044 AC SYSTEM SIZE: 7.672 kW AC DC SYSTEM SIZE: 9.72 kW DCLat, 44.7128383Long, -93.1855731(27) Silfab SIL-360 NX mono PERC PVMODULES(14) AP Systems YC600 INVERTER(S)DATE:September 28, 2021Everlight Solar Construction7369 Highway 13 WSavage, MN 55378License# BC771658833.786.4387 ext. 701CONTRACTOR INFORMATION:PHOTOVOLTAIC ARRAY STRUCTURAL CRITERIA:PV MODULE COUNT:27ARRAY AREA:MODULE COUNT * 18.06ft² = 487.62ROOF AREA:2225 ft²PERCENT OF ROOF COVERED:22%ARRAY WEIGHT:MODULE COUNT * 50lbs = 1350DISTRIBUTED LOAD:ARRAY LBS/ATTACHMENTS = 25.96POINT LOAD: (lbs/ft²)(ARRAY) WEIGHT/AREA = 2.77 lbs/ft²ROOF ATTACHMENTS - PV03DRAWN BY: SoloCAD3' TYP18" TYP),5(3$7+:$<$&&(66),5(3$7+:$<$&&(66
5$,//)227$77$&+0(17%5$&.(7(522))5$0,1*48,&.%2/74%)/$6+,1*3902'8/((&2036+,1*/(522)/$<(55$,/(1'&/$033902'8/(0,'&/$033902'8/(0,1'(37+5$,/5$,/)/$6+,1* 48,&.%2/74%2'-8" MIN -3'-10" MAX5$,/3902'8/(" MAX."1'-8"MAX.FRONT VIEW10" MIN -1'-4"MAX2'-8" MIN -3'-10" MAX10" MIN -1'-4"MAXSIDE VIEW(5$)7(5723&+25'6(5$)7(5723&+25'DETAIL, MOUNTING AND FLASHINGEND CLAMP DETAILS MID CLAMP DETAILSEQUIPMENT INFORMATION:RAIL MANUFACTURERIronRidgeRAIL PART NUMBERXR-10ATTACHMENTSQuickbolt 2 (QB2)ATTACHMENT QTY52SPLICE QTY6MIDCLAMP QTY42ENDCLAMP QTY24ROOF INFO:ROOF INFO:ROOF TYPEasphalt_shingleROOF FRAMINGmanufactured_trussRAFTER/TOP CHORD SIZE2x4RAFTER/TOP CHORD SPACING24"ATTACHMENT SPACING48Dakota ElectricSITE INFORMATIONThomas Hair16311 Fallbrook DrLakeville, MN 55044 AC SYSTEM SIZE: 7.672 kW AC DC SYSTEM SIZE: 9.72 kW DCLat, 44.7128383Long, -93.1855731(27) Silfab SIL-360 NX mono PERC PVMODULES(14) AP Systems YC600 INVERTER(S)DATE:September 28, 2021Everlight Solar Construction7369 Highway 13 WSavage, MN 55378License# BC771658833.786.4387 ext. 701CONTRACTOR INFORMATION:PHOTOVOLTAIC ARRAY STRUCTURAL CRITERIA:PV MODULE COUNT:27ARRAY AREA:MODULE COUNT * 18.06ft² = 487.62ROOF AREA:2225 ft²PERCENT OF ROOF COVERED:22%ARRAY WEIGHT:MODULE COUNT * 50lbs = 1350DISTRIBUTED LOAD:ARRAY LBS/ATTACHMENTS = 25.96POINT LOAD: (lbs/ft²)(ARRAY) WEIGHT/AREA = 2.77 lbs/ft²MOUNTING DETAIL - PV04DRAWN BY: SoloCAD
J-BOXSTRING (1): 15.96 A AC, 14 MODULESSTRING (2): 15.96 A AC, 13 MODULESNG3AC COMBINER BOXSOLAR LOADS ONLYUL 1741 COMPLIANTAC DCAC DC7 INVERTERSAC DCAC DC7 INVERTERSJ-BOX(N) 100A(2) 20A-2PJ-BOX12124(E) LOADSNG(E)GROUNDINGELECTRODEINTERCONNECTION NOTES1. GROUND FAULT PROTECTION IN ACCORDANCE WITH [NEC 215.9] & [NEC 230.95]2. SUPPLY SIDE INTERCONNECTION ACCORDING TO [NEC705.12(A)] WITH SERVICE ENTRANCE CONDUCTORS INACCORDANCE WITH [NEC 240.21(B)]DISCONNECT NOTES1. DISCONNECTING SWITCHES SHALL BE WIRED SUCH THAT WHEN THE SWITCH IS OPENED THE CONDUCTORSREMAINING LIVE ARE CONNECTED TO THE TERMINALS MARKED “LINE SIDE” (TYPICALLY THE UPPER TERMINALS)2. AC DISCONNECT MUST BE ACCESSIBLE TO QUALIFIED UTILITY PERSONNEL, BE LOCKABLE, AND BE AVISIBLE-BREAK SWITCH.3. FUSED AC DISCONNECT TO BE USED.(E)120/240 VAC TO UTILITY GRIDSUPPLY SIDE CONNECTION:NEC 230.46, NEC 230.79,NEC 705.12(A).K4977-INT MILBANKLUG KIT TO BE ADDED(E) 200A-2P(E) 200A MAIN SERVICE PANELUTILITY PV PRODUCTIONMETER BASE44(N) 40A FUSESPV AC DISCONNECT60A FUSED, AIC 10kAVISIBLE, LOCKABLE,LABELED, OPEN240V, 2-POLEDATE:September 28, 2021SITE INFORMATIONThomas Hair16311 Fallbrook DrLakeville, MN 55044 AC SYSTEM SIZE: 7.672 kW AC DC SYSTEM SIZE: 9.72 kW DCLat, 44.7128383Long, -93.1855731(27) Silfab SIL-360 NX mono PERC PVMODULES(14) AP Systems YC600 INVERTER(S)Dakota ElectricEverlight Solar Construction7369 Highway 13 WSavage, MN 55378License# BC771658833.786.4387 ext. 701CONTRACTOR INFORMATION:GROUNDING & GENERAL NOTES:1. PV INVERTER IS UNGROUNDED, TRANSFORMER-LESS TYPE.2. DC GEC AND AC EGC TO REMAIN UNSPLICED, OR SPLICED TO EXISTING ELECTRODE3. ANY EXISTING WIRING INVOLVED WITH PV SYSTEM CONNECTION THAT IS FOUND TO BEINADEQUATE PER CODE SHALL BE CORRECTED PRIOR TO FINAL INSPECTION.4. JUNCTION BOX QUANTITIES, AND PLACEMENT SUBJECT TO CHANGE IN THE FIELD - JUNCTIONBOXES DEPICTED ON ELECTRICAL DIAGRAM REPRESENT WIRE TYPE TRANSITIONS.5. AC DISCONNECT NOTED IN EQUIPMENT SCHEDULE OPTIONAL IF OTHERAC DISCONNECTING MEANS IS LOCATED WITHIN 10' OF SERVICE DISCONNECT.LINE DIAGRAM - PV05DRAWN BY: SoloCADVISIBLE, LOCKABLE,LABELED AC DISCONNECTLOCATED WITHIN 10'OF UTILITY METERConduit & Conductor ScheduleTAGWIRE GAUGEDESCRIPTIONQTYCONDUIT SIZECONDUCTORRATING# OF CONDUCTORSDERATETEMP. DERATECONDUCTOR RATINGW/DERATESCONDUIT FILL112-2TC-ER, THWN-2, COPPER (L 1, L 2)(2)N/A - FREE AIR30AN/A - FREE AIR0.9628.8AN/A - FREE AIR6 AWGBARE, COPPER (GROUND)(1)210 AWGTHWN-2, or THHN, or 10/2 NM-B COPPER - (L 1, L 2)(2)3/4" EMT40A10.9638.4A11.9%10 AWGTHWN-2, or THHN, or 10/2 NM-B COPPER - (GROUND)(1)310 AWGTHHN/THWN-2, COPPER - (L1, L2)(4)3/4" EMT40A0.80.9630.72A19.8%10 AWGTHHN/THWN-2 - (GROUND)(1)46 AWGTHWN-2 COPPER - (L1, L2, NEUTRAL)(3)3/4" EMT65A10.9662.4A35.5%8 AWGTHWN-2 COPPER - (GROUND)(1)EQUIPMENT SCHEDULE:TYPE:QTY:DESCRIPTION:RATING:MODULES:(27)Silfab SIL-360 NX mono PERC360 WINVERTERS:(14)AP Systems YC600548 WAC DISCONNECT(S):(1)PV AC DISCONNECT, 240V, 2-POLE60ALINE SIDELOAD SIDE
Dakota ElectricSITE INFORMATIONThomas Hair16311 Fallbrook DrLakeville, MN 55044 AC SYSTEM SIZE: 7.672 kW AC DC SYSTEM SIZE: 9.72 kW DCLat, 44.7128383Long, -93.1855731(27) Silfab SIL-360 NX mono PERC PVMODULES(14) AP Systems YC600 INVERTER(S)DATE:September 28, 2021Everlight Solar Construction7369 Highway 13 WSavage, MN 55378License# BC771658833.786.4387 ext. 701CONTRACTOR INFORMATION:LABEL 6MARKED AT AC DISCONNECTING MEANS.[NEC 690.54]LABEL 5EQUIPMENT CONTAINING OVERCURRENTDEVICES IN CIRCUITS SUPPLYING POWER TOA BUSBAR OR CONDUCTOR SUPPLIED FROMMULTIPLE SOURCES SHALL BE MARKED TOINDICATE THE PRESENCE OF ALLSOURCES.[NEC 705.12(B)(2)(3)(c)]LABEL 3PLACED ADJACENT TO THE BACK-FED BREAKERFROM THE INVERTER IF TIE IN CONSISTS OFLOAD SIDE CONNECTION TO BUSBAR.[NEC 705.12(B)(2)(3)(c)]*ELECTRICAL DIAGRAM SHOWN ABOVE IS FOR LABELING PURPOSES ONLY. NOT AN ACTUAL REPRESENATION OF EQUIPMENT AND CONNECTIONS TO BE INSTALLED. LABELLOCATIONS PRESENTED MAY VERY DEPENDING ON TYPE OF INTERCONNECTION METHOD AND LOCATION PRESENTED ON THE ELECTRICAL DIAGRAM PAGE.JUNCTION BOXOR COMBINER BOXMAIN SERVICE PANELAC DISCONNECTEXISTING SUB PANEL(IF WHERE POINT OFINTERCONNECTIONIS MADE)PV COMBINERSUBPANEL -IF USED TO COMBINEPV OUTPUT CIRCUITSACDCINVERTER (S)INTEGRATED DC DISCONNECT28695(ONLY IF PVINTERCONNECTIONCONSISTS OF LOADSIDE BREAKER)71115(ONLY IF PVINTERCONNECTIONCONSISTS OF LOADSIDE BREAKER)73LABELING DIAGRAM:LABEL 7AT DIRECT-CURRENT EXPOSED RACEWAYS, CABLE TRAYS, COVERSAND ENCLOSURES OF JUNCTION BOXES, AND OTHER WIRING METHODS;SPACED AT MAXIMUM 10FT SECTION OR WHERE SEPARATED BYENCLOSURES, WALLS, PARTITIONS, CEILINGS, OR FLOORS.[NEC 690.31(D)(2)]LABEL 9SIGN LOCATED ON OR NO MORE THAN 3FTFROM INITIATION DEVICE [NEC 690.56(C)(2)].LABEL 8FOR PV SYSTEMS THAT SHUT DOWN THE ARRAY ANDCONDUCTORS LEAVING THE ARRAY:SIGN TO BE LOCATED ON OR NO MORE THAN 3 FT AWAY FROMSERVICE DISCONNECTING MEANS TO WHICH THE PV SYSTEMSARE CONNECTED AND SHALL INDICATE THE LOCATION OF ALLIDENTIFIED RAPID SHUTDOWN SWITCHES IF NOT AT THE SAMELOCATION.[NEC 690.56(C)(1)(A)]LABEL 1PLACED ON THE MAIN DISCONNECTING MEANS FORTHE PV SYSTEM.[NEC 690.13(B)]LABELING NOTES:1.LABELS CALLED OUT ACCORDING TO ALL COMMON CONFIGURATIONS. ELECTRICIAN TODETERMINE EXACT REQUIREMENTS IN THE FIELD PER CURRENT NEC AND LOCAL CODES ANDMAKE APPROPRIATE ADJUSTMENTS.2.LABELING REQUIREMENTS BASED ON THE 2020 NATIONAL ELECTRIC CODE, OSHA STANDARD19010.145, ANSI Z535.3.MATERIAL BASED ON THE REQUIREMENTS OF THE AUTHORITY HAVING JURISDICTION.4.LABELS TO BE OF SUFFICIENT DURABILITY TO WITHSTAND THE ENVIRONMENT INVOLVED[NEC 110.21]5.LABELS TO BE A MINIMUM LETTER HEIGHT OF 3/8", WHITE ON RED BACKGROUND;REFLECTIVE, AND PERMANENTLY AFFIXED [IFC 605.11.1.1]341LABEL 4PLACED ON EQUIPMENT CONTAINING OVERCURRENTDEVICES IN CIRCUITS SUPPLYING POWER TOA BUSBAR OR CONDUCTOR SUPPLIED FROMMULTIPLE SOURCES[NEC 705.10(C)]2341LABEL 2FOR PV DISCONNECTING MEANS WHERE THE LINE ANDLOAD TERMINALS MAY BE ENERGIZED IN THE OPENPOSITION.[NEC 690.13(B)]:$51,1*!7(50,1$/6217+(/,1($1'/2$'6,'(60$<%((1(5*,=(',17+(23(1326,7,21!:$51,1*7+,6(48,30(17,6)('%<08/7,3/(6285&(6727$/5$7,1*2)$//29(5&855(17'(9,&(6(;&/8',1*0$,16833/<29(5&855(17'(9,&(6+$//127(;&(('$03$&,7<2)%86%$53+27292/7$,&$&',6&211(&75$7('$&287387&855(17120,1$/23(5$7,1*$&92/7$*((/(&75,&6+2&.+$=$5'0$,13+27292/7$,&6<67(0',6&211(&7:$51,1*!32:(56285&(287387&211(&7,21'21275(/2&$7(7+,629(5&855(17'(9,&(:$51,1*!'8$/32:(56285&(6(&21'6285&(,63+27292/7$,&6<67(03+27292/7$,&32:(56285&(TURN RAPID SHUTDOWNSWICH TO THE "OFF"POSITION TO SHUT DOWNPV SYSTEM AND REDUCESHOCK HAZARD IN ARRAYSOLAR PV SYSTEM EQUIPPEDWITH RAPID SHUTDOWNSOLAR ELECTRICPV PANELS5$3,'6+87'2:16:,7&+)2562/$5396<67(032240LABELS - PV06DRAWN BY: SoloCAD
JBJBACPVMSPMCDakota ElectricSITE INFORMATIONThomas Hair16311 Fallbrook DrLakeville, MN 55044 AC SYSTEM SIZE: 7.672 kW AC DC SYSTEM SIZE: 9.72 kW DCLat, 44.7128383Long, -93.1855731(27) Silfab SIL-360 NX mono PERC PVMODULES(14) AP Systems YC600 INVERTER(S)DATE:September 28, 2021Everlight Solar Construction7369 Highway 13 WSavage, MN 55378License# BC771658833.786.4387 ext. 701CONTRACTOR INFORMATION:POWER TO THIS BUILDING IS ALSO SUPPLIED FROM ROOF MOUNTEDSOLAR ARRAYS WITH SAFETY DISCONNECTS AS SHOWN:CAUTIONDIRECTORYPERMANENT PLAQUE OR DIRECTORY PROVIDING THE LOCATION OF THESERVICE DISCONNECTING MEANS AND THE PHOTOVOLTAIC SYSTEM.(ALL PLAQUES AND SIGNAGE WILL BE INSTALLED AS OUTLINED WITHIN:NEC 690.56(B)&(C), [NEC 705.10])PV ARRAYMAIN DISTRIBUTIONUTILITY DISCONNECT16311 Fallbrook Dr, Lakeville MN 55044FRONT OF HOMESYSTEM UTILIZESMICROINVERTERS LOCATEDUNDER EACH SOLAR MODULEPLACARD - PV07 DRAWN BY: SoloCADRAPID SHUTDOWN ACDISCONNECT SWITCH
Dakota ElectricSITE INFORMATIONThomas Hair16311 Fallbrook DrLakeville, MN 55044 AC SYSTEM SIZE: 7.672 kW AC DC SYSTEM SIZE: 9.72 kW DCLat, 44.7128383Long, -93.1855731(27) Silfab SIL-360 NX mono PERC PVMODULES(14) AP Systems YC600 INVERTER(S)DATE:September 28, 2021Everlight Solar Construction7369 Highway 13 WSavage, MN 55378License# BC771658833.786.4387 ext. 701CONTRACTOR INFORMATION:SITE PHOTOS:SITE PHOTOS - PV08 DRAWN BY: SoloCAD
Dakota ElectricSITE INFORMATIONThomas Hair16311 Fallbrook DrLakeville, MN 55044 AC SYSTEM SIZE: 7.672 kW AC DC SYSTEM SIZE: 9.72 kW DCLat, 44.7128383Long, -93.1855731(27) Silfab SIL-360 NX mono PERC PVMODULES(14) AP Systems YC600 INVERTER(S)DATE:September 28, 2021Everlight Solar Construction7369 Highway 13 WSavage, MN 55378License# BC771658833.786.4387 ext. 701CONTRACTOR INFORMATION:SITE PHOTOS:FRONT/BACK VIEWS - PV08.1DRAWN BY: SoloCAD
Dakota ElectricSITE INFORMATIONThomas Hair16311 Fallbrook DrLakeville, MN 55044 AC SYSTEM SIZE: 7.672 kW AC DC SYSTEM SIZE: 9.72 kW DCLat, 44.7128383Long, -93.1855731(27) Silfab SIL-360 NX mono PERC PVMODULES(14) AP Systems YC600 INVERTER(S)DATE:September 28, 2021Everlight Solar Construction7369 Highway 13 WSavage, MN 55378License# BC771658833.786.4387 ext. 701CONTRACTOR INFORMATION:SITE PHOTOS:SIDE VIEWS - PV08.2 DRAWN BY: SoloCAD
Dakota ElectricSITE INFORMATIONThomas Hair16311 Fallbrook DrLakeville, MN 55044 AC SYSTEM SIZE: 7.672 kW AC DC SYSTEM SIZE: 9.72 kW DCLat, 44.7128383Long, -93.1855731(27) Silfab SIL-360 NX mono PERC PVMODULES(14) AP Systems YC600 INVERTER(S)DATE:September 28, 2021Everlight Solar Construction7369 Highway 13 WSavage, MN 55378License# BC771658833.786.4387 ext. 701CONTRACTOR INFORMATION:SITE PHOTOS:METER/OPEN MSP - PV08.3 DRAWN BY: SoloCAD
BAAARRABAAARRAINDUSTRY LEADING WARRANTYAll our products include an industry leading 25-year product workmanship and 30-year performance warranty.35+ YEARS OF SOLAR INNOVATIONLeveraging over 35+ years of worldwide experience in the solar industry, Silfab is dedicated to superior manufacturing processes and innovations such as Bifacial and Back Contact technologies, to ensure our partners have the latest in solar innovation.NORTH AMERICAN QUALITYSilfab is the leading automated solar module manufacturer in North America. Utilizing premium quality materials and strict quality control management to deliver PV modules. BAA / ARRA COMPLIANTSilfab panels are designed and manufactured to meet Buy American Act Compliance. The US State Department, US Military and FAA have all utilized Silfab panels in their solar installations. LIGHT AND DURABLE Engineered to accommodate high wind load conditions for test loads validated up to 4000Pa uplift. The light-weight frame is exclusively designed for wide-ranging racking compatibility and durability.QUALITY MATTERS Total automation ensures strict quality controls during the DOMESTIC OPERATIONSOur 500+ North American team is ready to help our partners win the hearts and minds of customers, providing customer AESTHETICALLY PLEASINGcommercial applications.PID RESISTANTPID Resistant due to advanced cell technology and material selection. In accordance to IEC 62804-1.* Chubb provides error and omission insurance to Silfab Solar Inc.ProudPartner ofSilfab Solar Inc.240 Courtneypark Drive EastMississauga ON L5T 2Y3 CanadaTel +1 905-255-2501 | Fax +1 905-696-0267info@silfabsolar.com | www.silfabsolar.comSilfab Solar Inc.800 Cornwall AveBellingham WA 98225 USATel +1 360-569-4733SIL-360 NX mono PERCTest Conditions STC NOCTModule Power (Pmax) Wp 360 258Maximum power voltage (Vpmax) V 36.6 33.1Maximum power current (Ipmax) A 9.9 7.8Open circuit voltage (Voc) V 44.5 40.4Short circuit current (Isc) A 10.5 8.2%19.7 17.6Maximum system voltage (VDC) V 1000Series fuse rating A 20Power Tolerance Wp 0 to +10• Sun simulator calibration reference modules from Fraunhofer Institute. Electrical characteristics may vary by ±5% and power by 0 to +10W.SIL-360 NX mono PERC +0.064 %/°C-0.28 %/°C-0.36 %/°CNOCT (± 2°C) 46 °COperating temperature -40/+85 °CSIL-360 NX mono PERCMetric ImperialModule weight 20±0.2 kg 44±0.4 lbsDimensions (H x L x D) 1832 mm x 1000 mm x 38 mm 72.13 in x 39.4 in x 1.5 inMaximum surface load (wind/snow)* 4000 Pa rear load / 5400 Pa front load 83.5/112.8 lb/ft^2Hail impact resistance ø 25 mm at 83 km/h ø 1 in at 51.6 mphCells66 - Si mono-PERC - 5 busbar158.75 x 158.75 mm66 - Si mono-PERC - 5 busbar62.25 x 62.25 inGlass3.2 mm high transmittance, tempered, 0.126 in high transmittance, tempered, Cables and connectors (refer to installation manual)1200 mm ø 5.7 mm, MC4 from Staubli 47.2 in, ø 0.22 (12AWG), MC4 from Staubli BacksheetFrame Anodized Aluminum (Black)Bypass diodesJunction BoxSIL-360 NX mono PERCModule product workmanship warranty 25 years**Linear power performance guarantee30 yearsst year91.6% end 12th year 85.1% end 25th year 82.6% end 30th yearSIL-360 NX mono PERCProductULC ORD C1703, UL1703, CEC listed***, UL 61215-1/-1-1/-2, UL 61730-1/-2, IEC 61215-1/-1-1/-2***. IEC 61730-1/-2***, CSA C22.2#61730-1/-2, IEC 62716Ammonia Corrosion; IEC61701:2011 Salt Mist Corrosion Certifed, UL Fire Rating: Type 2Factory ISO9001:2015All states except CaliforniaModules Per Pallet: 26Pallets Per Truck: 34Modules Per Truck: 8847.87" [200mm]16.67" [423.5mm]38.78" [985mm]2.36" [60mm]38.11" [968mm]Mounting Hole(x4)Drainage (x8)Ø4.2mm (x2)Grounding Hole47.24"[1200mm]39.37" [1000mm]72.13" [1832mm]1.5" [38mm]72.13" [1832mm]1.02" [26mm]0.07" [1.8mm]1.5" [38mm]0.47" [12mm]0.39" [10mm]0.28" [7mm]CC* Warning. Read the Safety and Installation Manual installing and operating modules.**12 year extendable to 25 years subject to regis-tration and conditions outlined under “Warranty” at www.silfabsolar.com.data are available for download at: www.silfabsolar.com/downloads.CaliforniaModules Per Pallet: 26Pallets Per Truck: 32Modules Per Truck: 832Everlight SolarTel 833-786-4387www.everlightsolar.com