HomeMy WebLinkAbout19105 Indora TrCITY OF LAKEVILLE CERTIFICATION OF GRADING AND FINAL PLACEMENT OF IRON MONUMENTS Building Permit #:187780 Legal Description: Lot 11 Block 1 RECEIVED By Joey Pesik at 11:02 am, Oct 10, 2021 Subdivision: SUMMERLYN 8TH ADDITION Address: 19105 Indora Trail We -F hereby certify that on 5th day of October 2021 an inspection of this property was conducted by me or under my direct supervision and that the as -built grades, elevations and drainage patterns of the site and building are in conformance with the grading plan approved by the City Engineer or amendments previously approved by the City Engineer. In addition, all property corner monuments are in place as of this date. Exceptions noted. I hereby certify that this survey, plan or report was prepared by me or under my direct supervision and that I am a duly Licensed Land Surveyor under the laws of the State of Minnesota. Print Name: (/P ter /1/ Hawkinson Signature: c Date: October 5, 2021 MN License #: 42299 NOTE: ATTACH A COPY OF THE CERTIFICATE OF SURVEY SHOWING ALL AS - BUILT GRADES, ELEVATIONS AND DRAINAGE PATTERNS Approved subdivision grading plans should be obtained from the property owner or developer. General questions relating to the building permit should be directed to the Building Inspections Department at 952-985-4440. Questions relating to grading should be directed to the Engineering Department at 952-985-4500. Prior to release of the Grading Security, this document shall be filed with: City of Lakeville Engineering Department 20195 Holyoke Avenue Lakeville, MN 55044 Encls. 1 11X17 ��j� 1'1// 561 2 x 9'�0\ �0 1,9 �6? ,0j 0, 6 )g6 S 1 �G rI ,0)SS 110 x 4110 10)63 021 2 ,0, X , '021.6 0,8, Lot area = 16770 SF House area = 1948 SF Porch area = 124 SF Sidewalk area = 29 SF Driveway area = 677 SF Total Impervious Area = 2778 SF Impervious Coverage = 16.6% x X, n `t NS9 SO, S2., X O,S 0 x 4 0,, 3 REVISED 10/05/21 GRADING AS -BUILT Construction Notes: 1. Install rock construction entrance. 2. Install silt fence as needed for erosion control. 3. Sidewalks shall drain away from house a minimum of 1.0%. 4. Contractor must verify driveway design. 5. Contractor must verify service elevation prior to construction. 6. Add or remove foundation ledge as required. 7. Retaining walls are conditional; Wall installed if the grade exceeds 3:1. Wall will not be installed if the grade is 3:1 or less. General Notes: 1. Grading plan by Pioneer last dated 08-01-2019 was used to determine proposed elevations shown herein. 2. This survey does not purport to show improvements or encroachments, except as shown, as surveyed by me or under my direct supervision. 3. Proposed building dimensions shown are for horizontal location of structures on the lot only. Contact builder prior to construction for approved construction plans. 4. No specific soils investigation has been performed on this lot by the surveyor. The suitability of soils to support the specific house proposed is not the responsibility of the surveyor. 5. This certificate does not purport to show easements other than those shown on the recorded plat. 6. Bearings shown are based on an assumed datum. X, , ^O • 460 ■ X 000.00 ( 000.00 ) X x, 22>?6 Denotes iron pipe Denot= service Deno es television box Den.tes electric box De otes telephone box Denotes existing elevation Denotes proposed elevation Denotes drainage flow direction Denotes spike Denotes proposed retaining wall designed and built by others. ,066.9 10 4 X 706 .664, 1078.44 tob Lowest opening elevation per grading plan :1074.1 Lowest floor elevation per grading plan : 1070.6 House elevations Lowest Floor Elevation Top 0f Foundation Elev. (Proposed) / As -built :(1071.1) / :(1079.1) / 1079.1 Garage Slab Elev. ® Door : (1078.8) / 1078.7 T.O.F. Elevation ® Lookout: (1074.3) / 1074.4 0 i2 10j6 06, Nv- We hereby certify to Lennar Corporation that this survey, plan or report was prepared by me or under my direct supervision, and that I am a duly licensed Land Surveyor under the laws of the State of Minnesota, dated 12/28/20. BY: Signed: //Picyleer Er}gineering, P.A. Peter J. Hainsah, r fr otesrsfonal Land Surveyor Minnesota License No. 42299 email-phawkinson@pioneereng.com o' 10' 20' Scale: 1" = 20' Benchmark: Top Nut Hydrant Elevation = Revisions. 1.) 12-30-20 House Stake 2) 10-5-21 Grading As -built